Series A28 Two stage Thermostats. Feature and Benefits

Similar documents
Series A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

I ntroduction. Series F61. Liquid Flow Switches. Feature and Benefits

Series F61. Liquid Flow Switches. Feature and Benefits. T-body and Pipe-insert types available

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

270XT Freeze Protection, IP30

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications

A19, A28 Series Thermostats for Agricultural Buildings

A11 Series Low Temperature Cutout Controls

Frost Protection Thermostat

W43A Humidistat. Features and Benefits

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

TM-3100 Series Room Temperature Sensor

A99B Series Temperature Sensor

A99B Series Temperature Sensors

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

F261 Series Fluid Flow Switches

y Small dimensions. Easy to install in refrigerated counters or cold rooms

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

When ordering, please state type and code number. Max. Type - Capillary sensor of tube temp. charge length. C m

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance

MR3CCUHV Temperature/Defrost Control

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

Thermostat KPU. Data sheet

INSTALLATION AND USER INSTRUCTION MANUAL RENCOOL ECK4-48

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Thermostat, Differential thermostat RT

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Technical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat.

P266 Series Single-Phase Condenser Fan Speed Control

Data sheet Thermostatic sensors type RA 2000

Description. Applications

Powers Controls ET 134 Low Temperature Detection Thermostat

Davies Is Your #1 Source For Temperature Controls

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Capillary & Bulb Thermostatic Control & Fail-Safe Limit

Duct Temperature Sensors

Thermostat RT. Data sheet

TC-5231 Series, TC-5232, & TC-5241 Series

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

T7079A,B Solid State Remote Temperature Controllers

Use. For 2-pipe fan coils

Tubular Industrial Process

L62GB BASO Safety Shutoff Device

ETAF Series VDC Fan output LCD Fan Coil Thermostat

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

V48 Series 3-Way Water Regulating Valves For Cooling Tower Systems

Fan heater Panther Powerful fan heater for large premises

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Chromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

TEC2100 Series Networked Thermostats

TEMPERATURE & PRESSURE CONTROLS

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

Location Requirements

ET10 Series Stand-alone LCD Fan Coil Thermostat

ACT2-CS Convenience Store Controller

Frost Units for air temperature monitoring

XT Series Thermostats

Brasch Hazardous Location Unit Heaters

THERMASREG TR 040 THERMASREG TR 060

TEC210x-2 Series Networked Thermostats

13-1. Temperature Regulator

VIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014

! WARNING. Before using product, read and understand instructions.

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Fan Heater SW02 Quiet fan heater for connection to water in small buildings

The T6140A,B Remote Bulb Temperature Controller

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Powers TM Controls TH 188 Unit Mounted Thermostat

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

RA15/6T & TB Conversion Valve

Fan heater Panther WALL MOUNTED FAN HEATER

FS80-C Flow Switch. Features and Benefits. Allows user select the setting according the needs of system

Fan heater SWT Ceiling mounted fan heater with water heat

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

KSD301 Series 1/2 DISC BIMETAL THERMOSTAT

! WARNING. Before using product, read and understand instructions.

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

CME650 SERVICE PARTS

The heart of electric appliances ELECTRIC WATER HEATING MADE IN ITALY

Powers TM Controls ET 134 Line Voltage Room Thermostats

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

STEAMPRO. Steam Generator Troubleshooting and Service Guide

for relative humidity and temperature

Electromechanical cold controls for refrigerators and freezers MAKING MODERN LIVING POSSIBLE. Type description

USER S MANUAL AND INSTALLATION INSTRUCTIONS IMPORTANT

At a Glance. Well Conceived. Cabinet Systems. IT Solutions. Enclosures. Fire Protection. Thermal Components. Ducts, Accessories

Electric Water Heaters. The STRENGTHS of the product range in detail:

Transcription:

PSC9626 European Refrigeration Controls Catalogue Catalog Section 1 Product Bulletin A28 Series A28 Two stage Thermostats I ntroduction These thermostats are designed for various types of heating, cooling, ventilation, or airconditioning applications. All models have two SPDT switches providing the following control possibilities: - 2 stage heating - 2 stage cooling - heating/cooling with automatic changeover Models are provided with a standard IP30 case or splashproof, dust-tight IP65 plastic case D escription Controls are compact with fixed differential per stage and (on most models) adjustable differential between stages. Liquid filled element provides wide range, constant differential over whole range and no influence from barometric pressure. Since the bulb contains the major portion of the total fill the thermostat may by considered as cross-ambient, capillary and cup temperature variations affect the operating point only slightly due to the small amount of fill they contain. For quantity orders it is possible to have the below stated optional constructions - Without case and cover for panelmounting - Close differential per stage - Different capillary lengths All standard IP30 enclosure models have a universal way of adjustment. For this purpose a knob and sealing cap are enclosed. A28QA splashproof dust-tight thermostat with 2m capillary and style 1b bulb (left). A28AA thermostat with style 3 element (right). Feature and Benefits Liquid filled sensing element No cross ambient temperature problems Constant differential over the whole range Dust tight Penn switch Prevents pollution of the contacts by electrostatic influences. IP65 protection class models available Front adjustment Suitable for outdoor applications Less mounting space required 2001 Johnson Controls Inc. Catalogue Section 1

2 N ote A28 Switching diagram (Heating Mode) These controls are designed for use only as operating controls. Where an operating control failure would result in personal injury or loss of property it is the responsibility of the installer to add devices or systems that protect against, or warn of, control failure. A djustment Models "set low" (see also cover label): The dial indicates the switch point "SP1" (see switching diagram). Models "set high" (see also cover label): The dial indicates the switch point "SP2" (see switching diagram) For IP30 models the standard screwdriver adjustment can be converted easily in the field to knob adjustment. Also concealing of adjustment is possible after installation. Contact function Fig.2 A Differential per stage. B Differential between the stages. SP1 Dial setting (for exceptions see 'SP2'). SP2 Dial setting (range 0 to 43 C and 1 to 60 C). t Temperature increase. LO Low stage. HI High stage. q3 2 > q 2 > 1 HI 2 3 2 θ 2 > θ 1 > C 1 LO q 1 < q 2 R epair and Replacement Repair is not possible. In case of an improperly functioning control, please check with your nearest supplier. When contacting the supplier for a replacement you should state the type/model number of the control. This number can be found on the data plate or cover label. Fig. 1 1-2 closes on temperature increase. C Removable jumper. Catalogue Section 1 2001 Johnson Controls Inc.

A28 3 Type number selection table: Range ( C) Diff. per stage (K) Diff. between stages (K) Element style (cap. length) Bulb size (mm) Element finish Setting (see page 2 adjustment) Max. bulb temp ( C) Bulb well (optional) Order number Type A28AA Capillary Thermostats, General Purpose IP30-35 to +10 2 1 to 4 1b(2m) 9.5 x 110 Tin-plated set low 60 WEL14A602R A28AA-9006-5 to +28 1.5 1 to 4 1b(2m) 9.5 x 135 Tin-plated set low 60 WEL14A603R A28AA-9007-5 to +28 1.5 1 to 4 1b(5m) 9.5 x 135 Tin-plated set low 60 WEL14A603R A28AA-9106 1 to 60 2 1 to 4 1b(3m) 9.5 x 115 - set high 85 WEL14A602R A28AA-9118 Type A28AA Space thermostat 0 to +43 1.5 1 to 4 3 - St. Steel set high 60 - A28AA-9113 Type A28QA Capillary Thermostats, Splashproof IP65, Dust-tight Case -35 to +10 2 1 to 4 1b(2m) 9.5 x 110 Tin-plated set low 60 WEL14A602R A28QA-9110-5 to +28 1.5 1 to 4 1b(2m) 9.5 x 135 Tin-plated set low 60 WEL14A603R A28QA-9111-35 to +40 2 1 to 4 1b(3.5m) 9.5 x 110 Tin-plated set low 60 WEL14A602R A28QA-9114 1 to 60 2 1 to 4 1b(3m) 9.5 x 115 - set high 60 WEL14A602R A28QA-9115 Type A28QA Space Thermostats, Splashproof IP65, Dust-tight Case 0 to +43 1.5 1 to 4 3 - St. Steel set high 60 - A28QA-9113 Type A28QA Capillary Thermostats, Splashproof IP65, Dust-tight Case, Concealed adjustment. For use on cooling-towers evaporative condensers, or air cooled condensers 5 to 50 2 4 1b(2m) 9.5 x 110 St. Steel set low 100 WEL14A602R A28QA-9101 Type A28QJ Capillary Thermostats, Splashproof IP65, Dust-tight Case For use on heat pumps and heat recovery units 10 to 95 1.5 1 to 4 1b(3m) 9.5 x 100 - set low 115 WEL14A602R A28QJ-9100 Note: If what you need is not in the specific type numbering selection table then please contact your representative. Sensor styles Fig. 3 Style 1b swaged bulb, can be used with closed-tank connector FTG13A-600 Fig. 4 Style 3 (coil) 2001 Johnson Controls Inc. Catalogue Section 1

4 A28 Accessories (optional) 1 2 3 C A B Order no. Dimension A Dimension B Dimension C Internal WEL14A602R 125 mm 171 mm 9.8 mm WEL14A603R 147 mm 193 mm 9.8 mm 1. Bushing 2. Set screw 3. Adapter, 1/2"-14 NPT Bulb well (brass, copper pipe) Fig. 5 76 63 27 11.5 1 2 3 4 3 5 6 1/2"-14 NPT ø 5.5 (3x) 1. Style 1b bulb support tube 2. Packing nut 3. Washer 4. Packing 5. Adapter, 1/2"-14 NPT 6. Bulb Fig. 6 Duct flange to be used with closed-tank connector FTG13A600R. Order number T-752-1001 Fig. 7 Closed-tank connector Order number FTG13A600R Catalogue Section 1 2001 Johnson Controls Inc.

A28 5 Dimensions (mm) Fig. 8 A28AA (standard IP30 enclosure) 1 Reset lever 2 Knob packed separately with the control 3 22.3 mm dia. cable inlet hole for PG-16 4 Earth screw 2001 Johnson Controls Inc. Catalogue Section 1

6 A28 Dimensions (mm) Fig. 9 A28QA/QJ (splash-proof IP65, dust-tight enclosure) 1 Knob (knob models only) 2 Cable grommet Ø 5 to Ø 13 mm M 4 Mounting holes Ø 4.5 mm use 2 holes only Catalogue Section 1 2001 Johnson Controls Inc.

A28 7 N otes 2001 Johnson Controls Inc. Catalogue Section 1

8 A28 S pecifications Type number A28AA (standard IP30 enclosure) A28QA/QJ (splashproof, dust-tight IP65 enclosure) Element style Style 1b bulb element Application General purpose - Style 3 Style 1b bulb element Space Operating ranges See type number selection table Differentials See type number selection table - General purpose Cooling towers and air-cooled condensers Style 3 Space (out-door and agriculture) Adjustment Universal - External knob (general purpose) Concealed under cover (coolingtower and air-cooled condensers) Controls with adjustable differential between stages have an adjustment lever under the cover Material Case Cover 1.75 mm cold-rolled zinc plated steel 1.5 mm ABS plastic Polycarbonate Blue-colour finish Polycarbonate Blue-colour finish Conduit opening 22.3 mm dia. hole for PG16 Cable grommet. Conduit opening also applicable for PG16 connector Amb. temp. limits -35 to +55 C -35 to +55 C CE Conformity According to low voltage directive and EMC directive Electrical ratings ~15(5)A 230V ~15(5)A 230V (A28QJ: ~15(3)A) 230V) Shipping weight Enclosure IP30 IP65 ind. pack overpack 0.4 kg 10 kg (24 pcs.) 0.5 kg 12 kg (24 pcs.) The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office or representative. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products. - Johnson Controls International, Inc. Headquarters: Milwaukee, WI, USA European Headquarters: Westendhof 8, 45143 Essen, Germany European Factories: Lomagna (Italy), Leeuwarden (The Netherlands) and Essen (Germany) Branch Offices: Principal European Cities. This document is subject to change Printed in Europe Catalogue Section 1 2001 Johnson Controls Inc.