Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Similar documents
A study of Transient Performance of A Cascade Heat Pump System

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 35 41

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

ScienceDirect. Development progress of critical equipment in the CSNS cryogenic hydrogen system

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Design of Humidity Monitoring System Based on Virtual Instrument

Available online at ScienceDirect. Procedia Engineering 135 (2016 )

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Available online at ScienceDirect. Physics Procedia 67 (2015 )

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Available online at ScienceDirect. Procedia Engineering 84 (2014 )

Performance investigation of Air-conditioning system using ejector as expansion device

Full-scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater Tunnel

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Simulation of Full-scale Smoke Control in Atrium

The Effect of Quantity of Salt on the Drying Characteristics of Fresh Noodles

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

A Novel Heat Recovery System for High Temperature and High Humidity Gas Qing Hao1, a, Meng Si2, b

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Available online at ScienceDirect. Energy Procedia 70 (2015 ) Yanjun Dai*, Xian Li, Ruzhu Wang

Experimental Study of Initial Process of Frost on Heat Exchanger Surface of Refrigerated Transport Vehicle

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Study of R161 Refrigerant for Residential Airconditioning

International Engineering Research Journal Performance Analysis of Ejector Based Solar Air Conditioning System

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Application of the VRV Air-Conditioning System Heat Recovery Series in. Interior Zone and Analysis of its Energy Saving

Experimental and Numerical Study on the Performance of R410A Liquid Recirculation Cycles with and without Ejectors

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

Enhancing the performance of the domestic refrigerator with hot gas injection to suction line

R32 Compressor for Air conditioning and Refrigeration applications in China

Two-Pipe Fiber Bragg grating Temperature Sensor Applied in Cable Trench and Cable Pit

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

Heat transfer enhancement in an air process heater using semi-circular hollow baffles

SBS5311 HVACR II Experiment 2: Analysis of the Combined Rankine and Vapour Compression Cycle

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

INDOOR HUMAN THERMAL COMFORT OPTIMAL CONTROL WITH DESICCANT WHEEL COOLING SYSTEM

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

Performance Analysis of Solar Assisted Cascade Refrigeration System of Cold Storage System

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Low GWP Refrigerants for Air Conditioning Applications

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Experimental Research of Air Source Heat Pump Frosting and Defrosting in a. Double Stage-Coupling Heat Pump

Structure Improvement and Flow Field Analysis of Condenser in Freeze drying Equipment

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Procedia - Social and Behavioral Sciences 195 ( 2015 ) World Conference on Technology, Innovation and Entrepreneurship

Performance of an Improved Household Refrigerator/Freezer

Experimental Investigation of a Heat Pump Assisted Fluidized Bed Dryer

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Performance Assessment of Water Cooled Condenser Refrigeration System

REVIEW OF DESIGN OF SINGLE EFFECT SOLAR POWERED VAPOUR ABSORPTION AIR CONDITIONING SYSTEM

Global Journal of Engineering Science and Research Management

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

The Energy Consumption Investigation of the Hotel Central. Air-conditioning System and the Research of Energy Saving Measures

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Department of MCE, Islamic University of Technology 2. Abstract

STUDY ON HYBRID SYSTEM OF SOLAR POWERED WATER HEATER AND ADSORPTION ICE MAKER

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

ADVANCES in NATURAL and APPLIED SCIENCES

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Purdue e-pubs. Purdue University

Influences of temperature of vapour-condenser and pressure in the vacuum chamber on the cooling rate during vacuum cooling

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Experimental Investigation of a New High Temperature Heat Pump Using Water as Refrigerant for Industrial Heat Recovery

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Chapter 11 REFRIGERATION CYCLES

Study on an environmental simulation system of low/high temperature. for great space

Simulation study of evacuation in high-rise buildings

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

State Grid Zhejiang Electric Power Corporation Electric Power Research Institute, Hangzhou, , China

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

Development of Performance Test Facility of Positive Displacement CO2 Refrigerant Compressor

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

Transcription:

Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 121 (2015 ) 1238 1244 9th International Symposium on Heating, Ventilation and Air Conditioning (ISHVAC) and the 3rd International Conference on Building Energy and Environment (COBEE) Experimental Study of Plate Freezer with the Ejector X.C. Cao a, J. Q. Wan a, *, L.Y. Song a a College of food science and technology, Shanghai Ocean University, Shanghai, China Abstract This paper introduced a kind of fluid supply system on ejector throttling. Comparing with the fluid supply system of thermodynamic expansion valve this paper studied two kinds of fluid supply system on the freezing time overall energy consumption and uniformity temperature distribute. The results showed that, in this working condition, the fluid supply system of ejector is 14% shorter than the thermodynamic expansion valve in freezing time, which reducing the power consumption by shortening the working time of compressor, condenser and other equipment. Meanwhile, Ejector can act like isentropy and recycle some expansion work, which could increase the refrigerant capacity of evaporator to save about 6.3% power consumption compared with the isoenthalpy throttling of thermodynamic expansion valve. The system can reducing 10 C temperature difference by avoiding two-phase flow fluid supply of the evaporator and reduce the flow resistance of refrigerant in evaporator. Thus, the quality of the product is improved. 2015 The The Authors. Published by Elsevier by Elsevier Ltd. This Ltd. is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Peer-review under responsibility of the organizing committee of ISHVACCOBEE 2015. Peer-review under responsibility of the organizing committee of ISHVAC-COBEE 2015 Keywords: Ejector, Thermal expansion valve, Freezing time, Energy consumption, Uniformity temperature distribute *Corresponding author. Tel.: 15692165875 E-mail address: jqwan@shou.edu.cn 1877-7058 2015 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Peer-review under responsibility of the organizing committee of ISHVAC-COBEE 2015 doi:10.1016/j.proeng.2015.09.151

X.C. Cao et al. / Procedia Engineering 121 ( 2015 ) 1238 1244 1239 1. Introduction As the economy develops with speed, energy saving has become one of the significant topic among the field of refrigeration and air-condition. Throughout the researches at home and abroad, we can find that the main cooling energy saving researches focus on the design of refrigeration cycle, the improvement on compressor techniques, the enhancement on heat exchange performance of condenser and evaporator and the new refrigerant, rarely on the throttling. In order to reduce the loss of throttling, scholars around the world have conducted some researches, among which the replacement of expansion valve with ejector is one of the programs with the biggest research value and application prospect [1]. In 1910, Maurice Leblanc proposed ejector used for jet refrigeration system for the first time [2]. It had been used in cooling system driven by low-grade heat source, which is a good way to recycle the waste heat. Internally, the research on this field is comparatively mature [3-5]. But the real application of ejector into vapor compression refrigeration system began in the late 1980s. Lorentzen replaced the throttling valve with ejector, which drives the recycle of refrigerant to enhance the evaporator s performance [6]. Kornhauser had put forward that expansion throttling loss could be recycled by compression/ejection mixed compression refrigeration cycle which can improve the cooling efficiency of refrigeration system [7]. Dopazo and Seara used two ejection in the NH3/CO2 cascade plate freezing to achieve the goal of energy saving through increasing the fluid recirculation rate to more than 3 as evaporation temperature rises [8-9]. Minetto and other experts applied the double fluid supply by ejector into air conditioning system and studied the temperature distribution of evaporator. The results suggest that ejection could adapt itself to variable working condition [10]. At home, Fuzhou refrigration equipment company had put forward the idea of single-stage compression plate frezzer fed by ejector in 1992 [11]. And the plate freezer improves constantly based on experiments. The liquid in the single-stage compression refrigeration system is provied by ejection, which could enhance the cooling effects of evaporator and reduce freezing time by the increasement of mass flow rate of refrigerant in the plate evaporator caused by the advancement of ejecting coefficient and multiplication rate. The research team authorized invention patent "a fluid supply system of ejector throttling" in 2015 [12], which could recycle some expansion work and raise the pressure of compressor. Thus, the system could make the evaporator supply double fluid without circulation liquid pump and its power consumption. The patent theoretically analysis the feasibility, but the energy-saving features of the ejector have not yet publish experimental data. 2. Description of the chiller system and data envelopment analysis 2.1. New system Based on the features of ejector to reduce throttling losses and eject low pressure, patent proposes a new fluid supply system of ejector throttling by figure1. Vapor-liquid separator 1 could make the vapor in the refrigerant twophase flow from ejector back into compressor through middle vapor suction mouth and the fluid in the refrigerant two-phase flow from ejector into evaporator. The present invention patent has the following advantages: 1. It could make the vapor in the refrigerant twophase flow back into compressor directly, which avoid the waste of refrigerant vapor obtained the expansion work. 2. It could achieve that the pure liquid refrigeration flow into the evaporator, which reduce the flow resistance of the two-phase refrigerant in the evaporator and improve the heat exchange efficiency. 3. The system could make the evaporator supply double fluid without circulation liquid pump and its power consumption. 4. Simple structure, easy application, which can be used in various forms of air conditioning, refrigeration and cryogenic systems to save energy.

1240 X.C. Cao et al. / Procedia Engineering 121 ( 2015 ) 1238 1244 Fig. 1. schematic diagram of ejector system However, due to the difficult compressor manufacturing process of the center suction mouth, it is hard to find this kind of compressor among the market. This experiment chooses the system of Figure 2 which has no center air suction mouth different form Figure 1. The refrigerant vapor from vapor-liquid separator 1 is decompressed by valve and sucked by the compressor when it mixed with the refrigerant from vapor-liquid separation 2. By this way, the expansion work from the vapor cannot be used, but it lowers the requirements on the compressor and cuts the cost. 2.2. Experimental device Fig. 2. schematic diagram of ejector system (compressor without centre suction mouth) According to the design theory, this paper set up a experimental table for fluid supply system of ejector throttling. It will study the influence of two fluid supply systems namely thermodynamic expansion valve and ejector, on the energy consumption, uniform temperature distribution and freezing time. The experiment on ejector takes R22 as working medium, and the two fluid systems are in parallel illustrated by Figure 3.

X.C. Cao et al. / Procedia Engineering 121 ( 2015 ) 1238 1244 1241 10 9 8 7 6 V4 V5 YV1 V1 V3 YV2 V2 1 2 3 4 5 1-Electromagnetic valve 2-Seperator 2# 3-Ejector 4-Seperator 1# 5-Condenser 6-Compressor 7-Oil return heater 8-Pressure sensor 9-Plate freezer 10-Thermodynamic expansion valve Fig. 3. schematic diagram of two fluid supply systems Plate freezer adopts the PA/PF aluminum alloy plate freezer with the freezing capacity of 420~500kg per time, 25 m2 effective evaporation areas made by Nantong Sinrofreeze Equipment Ltd. Compressor uses S6F-30.2-40P Bitzer reciprocating double-stage compressor whose double-stage gas displacement is 101.4 m3/h. Condenser employs Bitzer FNH-1.2/4 air-cooled condenser. Throttling valve applies Danfoss TX2-068Z3209 thermodynamic expansion valve which could be used in low-temperature device for its evaporation temperature range is from -60 C to 50 C The core of this whole jet experiment is the ejector composed of nozzle, nozzle connecting pipe, suction chamber and diffusion chamber. Its main geometric sizes are shown in table 1 below. Table 1 The main geometry of ejector Minimum diameter of nozzle 5.06mm Inlet diameter of nozzle 20mm Diameter of suction chamber 40mm Length of the mixing chamber 216mm Diameter of mixing chamber 18mm Length of the diffuser chamber 180mm Angle of the diffuser chamber 16 In the experiment device of measurement system, T-thermocouple is applied in temperature sensor achieving the ±0.5 C accuracy; the model of electric comprehensive analysis tester is DZFC-1 with the 1.0 Class power measurement accuracy. Temperature recorder is Agilent 34980A which can record date per ten seconds. 2.3. The starting and operation of the experimental table This experiment is conducted in Shanghai for two continual days when the outdoor temperature is stable at 8~12 C. The subject used for freezing simulation is the sponge fully absorbing water and the surface could perfectly touch the surface of the up and below panel, which could reflect the actual condition of heat transfer. 6 trays are placed on every layer of plate which holds about 12.5kg sponge containing water. There are 7 layers with 42 trays in total weight up to 500kg. The initial temperatures and the weight of the two experiments are almost kept in the same level. Besides, the test points to measure the temperature of the products are chosen in the center of the sponge on very layer, 7 layers in total from the top. a. The fluid supply system of thermodynamic expansion valve including compressor, condenser, plate freezer and

1242 X.C. Cao et al. / Procedia Engineering 121 ( 2015 ) 1238 1244 thermodynamic expansion valve is applied in this experiment. First, turn off V2, V3, V4 and V5 valve shown on Figure 3. Second, turn on V1 valve (the other valves without directions are kept on) and start the power supply keeping the machine works normally. The refrigerant from condenser will be supplied to the plate evaporator for the cooling capacity needed after being throttled by the thermodynamic expansion valve. Consequently, refrigerant vapor are sucked by the compressor for circulation. When the temperatures of al test points reach -18 C, the experiments is completed. Then turn off the power. b. The fluid supply system of ejector throttling including compressor, ejector, plate freezer, vapor-liquid separation circulation barrel and vapor-liquid separation fluid supply barrel is applied in this experiment. First, turn off V1 valve. Second, turn on V2, V3, V4 and V5 valve (the other valves without directions are kept on) and start compressor to make the machine work normally. After a period of time, Vapor-liquid separator 2 liquid refrigerants will be sucked back by the ejector and be supplied in cycle to evaporator after the Vapor-liquid separator 1. When the temperatures of al test points reach -18 C, the experiments is completed. Then turn off the power. 3. Results and discussion Figure 4 and Figure 5 shows that the freezing curve graphs of the products by applying thermodynamic expansion valve and ejector fluid supply modes respectively. The initial temperatures of freezing products are about 8 C, when the center temperature dropped to 18 C, the experiment is over. 10 0-10 1 2 3 4 5 6 7-20 -30 0 50 100 150 200 1 ~7 indicate temperature measuring point of each plate Fig. 4. the freezing curve graphs of thermodynamic expansion valve 10 0-10 -20 1 2 3 4 5 6 7-30 0 50 100 150 200

X.C. Cao et al. / Procedia Engineering 121 ( 2015 ) 1238 1244 1243 1 ~7 indicate temperature measuring point of each plate Fig. 5. the freezing curve graphs of ejector system By comparing two different ways for freezing curve, this paper analyses the freezing time, the total energy consumption, maximum temperature difference when frozen products is complete and unit power consumption in table 2. Table 2. The freezing performance of two fluid supply system Freezing time Energy consumption Project min kw h Fluid supply Max temperature difference C Thermodynamic expansion 190 63.2 20 0.126 valve Ejector 163 59.2 10 0.118 unit power consumption kw h In terms of freezing time, the fluid supply system of ejector is 14% shorter than the thermodynamic expansion valve. This is because in the fluid supply system of ejector, the supply flow of refrigerant is much larger than the amount of evaporation and the inner surface of the plate is fully wetted, which enhancing the convective heat transfer of the refrigerant side, thereby increasing the heat transfer efficiency and shorten freezing time. At the same time, the freezing curve graph of Figure 5 is more centralized than that of Figure 4, which shorted the maximum temperature difference between freezing products and be more advantageous to the improvement of the product s quality. In addition, the results shows that the fluid supply system of ejector saves about 6.3 total energy consumption compared with thermodynamic expansion valve and its unit power consumption is minimal. The fluid supply system of ejector could provide evaporator with double fluid, as a result, heat transfer coefficient rises significantly and heat transfer temperature difference drops substantially, which could cut the irreversible loss and save the freezing time. In addition, it reduces the power consumption by shortening the working time of compressor, condenser and other equipment. Meanwhile, the ejector can recover part of the expansion work, thereby further improving the cooling capacity of the evaporator. 4. Conclusions Under the same operating conditions, the fluid supply of ejector systems has large refrigerant flow and high flow rate, which prompting the refrigerant pipe wall with a fuller contact and enhancing heat transfer, thus freezing time is 14% shorter than the thermodynamic expansion valve. Ejector can act like isentropy and recycle some expansion work. Meanwhile, it reduces the power consumption by shortening the working time of compressor, condenser and other equipment, which could increase the refrigerant capacity of evaporator to save about 6.3% power consumption compared with the isoenthalpy throttling of thermodynamic expansion valve. The system can make full use of heat exchange area of the evaporator, lower the product temperature in a close pace reducing 10 C temperature difference by avoiding two-phase flow fluid supply of the evaporator and reduce the flow resistance of refrigerant in evaporator. Thus, the quality of the product is improved. Ejector shares many advantages, such as simple structure, no moving parts, low cost, safe operation and convenient installation and maintenance. It could be applied in any flow pattern including two-phase flow, and there is no increment on the system complexity but the improvement on system performance when it is used in refrigeration cycle. The results of the experiment suggest that it is feasible to adopt the fluid supply system of ejector into the refrigeration system of plat freezer. It would have a brighter future if there is an improvement and enhancement on its system design, mating auxiliary machinery, ejector serialization and automation.

1244 X.C. Cao et al. / Procedia Engineering 121 ( 2015 ) 1238 1244 Acknowledgements The authors gratefully acknowledge Professor Jianguo Li, who owns the design of the system and built the refrigeration unit. At the same time, the authors wish to express thanks to Guoqiang Wang for the valuable discussion and recommendation.this work was partially supported by National High-tech R&D Program of China (863 Program), Number:2012AA092301. References [1] X.C. Cao, J.Q. Wan, Research status of ejector applied in the refrigeration system, Applied Cryogenics and Superconductivity. 42 (2014) 63-67. [2] K.Chunnanond, S. Aphornratana, Ejectors: applications in refrigeration technology, Applied Renewable and Sustainable Energy Reviews. 8 (2004) 129-155. [3] K. Chunnanoud, S. Aphornratana. An experimental investigation of a steam ejector refrigerator: the analysis of the pressure profile along the ejector, Applied Thermal Engineering. 24 (2004) 311-322. [4] A. Selvaraju, A. Mani, Analysis of a vapor ejector refrigeration system with environment friendly refrigerants, Applied International Journal of Thermal Sciences. 43 (2004) 915-921. [5] D. W. Sun, Refrigeration cycle operating with various refrigerants, Applied Energy Conversion and Management. 40 (1999) 873-884. [6] G. Lorentzen, Throttling, the internal haemorrhage of the refrigeration process, The Plenary Session of the 16th IIR Congress, Proceedings of the Institute of Refrigeration. (1983) 39-47. [7] A.A. Kornhauser, The use of an ejector as refrigerant expander, R-Purdue of 1990 US-NCPII R-Purdue Refrigeration Conference and ASHRAE-Purdue CFC Conference, Energy and Refrigeration. (1990) 10-19. [8] J.A. Dopazo, J.F. Seara, Experimental evaluation of an ejector as liquid recirculator in an overfeed NH3 system with plate evaporator, Applied International Journal Refrigeration. 34 (2011) 1676-1683. [9] J.A. Dopazo, J.F. Seara, Experimental evaluation of freezing processes in horizontal plate freezers using CO2 as refrigerant, Applied International Journal of Refrigeration. 35 (2012) 2093-2101. [10] S. Minetto, R. Brignoli, C. Zilio, Experimental analysis of a new method for overfeeding multiple evaporators in refrigeration systems, Applied International Journal of Refrigeration. 38 (2014) 1-9. [11] Y.S. Chen, Jet pump for plate freezer machine with single-stage compression, Applied Refrigeration Technology. 03 (1992) 81-84. [12] J.Q. Wan A fluid supply system of ejector throttling authorization no CN102878715A.