OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

Similar documents
РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

USER'S MANUAL PS

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

CENTRIFUGAL FANS user's manual. model VENTS VK.

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

AXIAL FANS USER S MANUAL

USER S MANUAL. VKP Series INLINE FAN

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Turbo. Service Instructions

Wind. Service instruction

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

Aero. Service Instructions

Centrifugal inline fans

HEAT RECOVERY AIR HANDLING UNIT

INTELLIGENT AXIAL FAN user's manual

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

Calm. Service Instructions

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

AXIAL DOMESTIC FANS. User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION

USER'S MANUAL INLINE CENTRIFUGAL FANS IN SOUND-INSULATED CASING VS, VS EC SERIES

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

Turbo Inline Fan, White - Non Illuminated Art no.33500

CENTRIFUGAL CEILING EXTRACT FAN

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

White - Non Illuminated Art no White - Cool White LED Art no.32600

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

AXIAL FANS user's manual. model Quiet

CENTRIFUGAL CEILING EXTRACT FAN

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

HEAT RECOVERY VENTILATOR

Axial intelligent fan USER S MANUAL

Installation manual Mini Comfort 50 S/L 07/ V EN

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

Air handling unit. BlauAir RH USER S MANUAL

USER S MANUAL DN-2. Drain pump

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

Series VENTS VUT R WH ЕС

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

GLEB Kitchen exhaust fan

G Installation manual Solitude - dmev unit

USER S OPERATION MANUAL HL-RD 2000 E EC HL-RD 3000 E ЕС

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

AIR HANDLING UNIT WITH HEAT RECOVERY

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

HEAT RECOVERY AIR HANDLING UNITS

FLUEBOOST. flueboost 350 gas fire model

Owner s Manual STAINLESS CONICAL CHIMNEY HOOD CONTENTS

Operating instructions for the DA 8-2 Extractor

Tools required. Pencil Drill Screwdriver Dowel (2 pcs.) Screws (2 pcs.)

Lo-Carbon Quadra Centrifugal Fan

INSTRUCTION MANUAL Wall mounted Cooker hood Nebel INOX 90

Centrif Duo & Centrif Duo Plus

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

ISCG90SS _03 ISCG90SS

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

KOMFORT EC DB Suspended heat recovery air handling units

Installation and Operating Instructions. Models: T4-12LOW-9IS

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

ART cm Island Curved Glass

ELTSHDC110SG/ Users Guide & Installation Instructions

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

100cm Chimney Hood GB IE

EH1210. airooncentre.co.uk. Peltier Dehumidifier Déshumidificateur Peltier. The Award Winning Ventilation Specialists

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Operating and Installation Instructions

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

Lucci Designer Hi Flow Exhaust Fan

Instructions for the Use and Care and Installation of ORW6XA ORW9XA. Wall Canopy Rangehoods

USER'S MANUAL. Micra 150 HEAT RECOVERY UNIT

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

Stainless Steel T-Box Extractor

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

User s Manual & Operating Instructions

Ceiling Mount Air Purification System

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

Stainless Steel Chimney Extractor

INSTALLATION INSTRUCTIONS USER GUIDE

Installation instructions. and User guide. Designer wall glass canopy NZ AU. HC90CGX1 & HC60CGX1 models

DESIGNER WALL CANOPY

Transcription:

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES F88EN-02.indd 1 04.09.2015 8:07:11

2 VKM ЕС CONTENT Introduction Use Structural designation key Delivery set Main technical data Fan design Safety requirements Mounting and installation guidelines Connection to power mains Maintenance Storage requirements Manufacturer s warranty Acceptance certificate Warranty card 4 4 5 5 7 9 10 10 11 11 F88EN-02.indd 2 04.09.2015 8:07:11

INTRODUCTION The present user manual contains the product description, technical data, operation, installation and mounting guidelines for the centrifugal inline fan of VKM EC series, hereinafter referred to as the fan. The centrifugal fan VKM EC, enclosed in a metal casing with the impeller diameter from 190 to 280 mm, is designed for ventilation of domestic, public and industrial premises that require economic solution and controllable ventilation. The applied EC motors enable reducing of power demand by 1.5- times and provide high efficiency and low noise level. The fan is designed for horizontal or vertical mounting in a round air duct and are used both for extract and supply ventilation. The fan is rated for continuous operation always connected to power mains. The fan must be grounded! Ingress Protection Rating IPX4. USE VKM X EC STRUCTURAL DESIGNATION KEY Fan with EC motor Exhaust spigot diameter 160; 200; 250; 15 mm. Centrifugal inline fan in metal casing Designation key example: VKM 200 EC - inline centrifugal fan in metal casing with EC motor for mounting in Ø 200 mm round air duct. The delivery set includes: - fan - 1 item; - fixing bracket for the fan mounting - 2 items; - user manual; - packing box. DELIVERY SET F88EN-02.indd 04.09.2015 8:07:12

4 VKM ЕС MAIN TECHNICAL DATA The fan designation, parameters and connecting dimensions are shown in tables 1, 2, and in fig. 1. Due to the constant improvements the design of some models may slightly differ from those described in this manual. The wiring diagram and terminal designation may also differ from the description in this manual. Table 1 Table 2 Table ErP data Overall efficiency ŋ, (%) Measurement category Efficiency category Efficiency grade Variable speed drive Power Current Air flow Static pressure MC EC N VSD [kw] [A] [m /h] [Pa] Speed [n/min -1 ] Specific ratio FAN DESIGN 1. casing 2. EC-motor. impeller 4. fixing bracket 5. terminal box Fan type SR Fig. 1 Dimensions, mm D D1 H B B1 L L1 L2 L Weight, kg VKM 160 EC 158 04 60 51 11 200 25 25 0 5,9 VKM 200 EC 198 44 47 90 50 28 25 25 40 7,1 VKM 250 EC 248 44 47 90 50 249 25 1 40 8,0 VKM 15 EC 1 404 466 454 414 260 25 40 40 8,5 Fan type Voltage [V / 50/60 Hz] Power [W] Current [A] Max. air capacity [m /h] RPM [min -1 ] Noise level at m [dba] Transported air temperature [ C] Protection rating VKM 160 EC* 1~ 20 80 0,58 660 250 45-25 +60 IPX4 VKM 200 EC* 1~ 20 84 0,49 840 2490 50-25 +60 IPX4 VKM 250 EC 1~ 20 161 0,94 1275 2700 46-25 +60 IPX4 VKM 15 EC 1~ 20 160 0,94 1460 2780 48-25 +60 IPX4 * Compliant to the ErP-regulation (EC) 27/2011, the power consumption at optimum efficiency is < 125W. F88EN-02.indd 4 04.09.2015 8:07:1

5 SAFETY REQUIREMENTS Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room through open chimney flues or other fire-protection devices. Mounting and maintenance of the fan are allowed only by duly qualified electricians in compliance with valid rated norms. Disconnect the fan from power mains prior to any servicing and repair works. Before connecting the fan to power mains check the fan for any visible damages of impeller and casing. The fan casing must not contain any foreign objects which can damage the impeller blades. WARNING: Do not use the fan in explosive or fire-hazardous environment. MOUNTING AND INSTALLATION GUIDELINES The fans are designed for vertical or horizontal mounting, fig. 2-5. Air motion in the system must be in compliance with the pointer direction on the fan casing. Install a hood on the intake spigot side in case of the vertical fan installation. Provide a straight air duct section at least 1 m long on the intake spigot side in case of the horizontal fan installation and the fan use in the humid environment. Fig. 2 Fig. 1 m Fig. 4 Fig. 5 F88EN-02.indd 5 04.09.2015 8:07:14

6 VKM ЕС Mounting sequence Disconnect the fan from power mains prior to any installation works, fig. 6. Remove the bolts on both sides of the casing 1, install the fixing brackets and tighten the bolts, fig. 7. Align the holes in the fixing brackets and the holes in the casing. Drill the holes in the wall or in the ceiling for the dowels and fix the fan with the screws, fig. 8-10. Connect the air ducts of respective diameter to the fan, fig. 11. Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 F88EN-02.indd 6 04.09.2015 8:07:15

7 CONNECTION TO POWER MAINS Cut power supply off before any operations with the fan. The fan must be connected to power mains by a duly qualified electrician. The rated electrical parameters of the fan are shown on the sticker. Any modifications of the internal connections are not allowed and will void the warranty. The fan is rated for connection to single-phase ac 20 V / 50 Hz power mains. Connect the fan to power mains by means of insulated, durable and thermal-resistant cords (cables, wires) with respective cross section, in any case no less 0.75 mm 2. The above cross section is for reference only. The applicable cable must be selected in consideration of the maximum wire temperature depending on the wire and insulation type, the maximum current, the lead wire length and its layout type. Install the automatic circuit breaker at the external electric input 20 V / 50 Hz and integrate it into the fixed wireworks. Install the automatic circuit breaker in such a way to provide quick unhampered access to it in case of emergency. The trip current must be in compliance with the fan current consumption. The recommended rated current for all the fan models is 1.6 A. Connect the cables to the terminal block incorporated inside the terminal box located on the fan casing in compliance with the fan wiring diagram and the terminal designation. The terminal designations are shown on the sticker inside the fan casing. The fan wiring diagram is shown in fig. 12 L L ~20 V 50 Hz N PE ~20 V 50 Hz N PE QF L Х1 1 QF L Х1 1 N 2 N 2 RE RE NC 4 NC 4 Х2 5 Fig. 12 Recommended speed controller VENTS R- 1/010 +10V CTR GND +10V 0-10V GND 1 2 Recommended speed controller VENTS R- 1/010 +10V CTR GND COM +10V 0-10V GND 6 7 8 9 The fan has smooth speed control due to the speed controller R-1/010, hereinafter the controller. Set the required speed from minimum to maximum value. The controller is an optional item and is available upon separate order. Connect the speed controller in compliance with the wiring diagram, fig. 12. F88EN-02.indd 7 04.09.2015 8:07:15

8 VKM ЕС Fig.1 Fig. 14 Fig. 15 Fig. 16 Fig. 17 F88EN-02.indd 8 04.09.2015 8:07:16

9 MAINTENANCE Disconnect the fan from power mains prior to maintenance and servicing operations, fig. 18. Maintenance means regular cleaning of the fan surfaces from dust and dirt. Use a soft dry brush or a vacuum cleaner to remove dust, fig. 21. Clean the impeller blades at least once in 6 months. Install the filter to prevent the fan soiling and reduce the maintenance periodicity. Remove the screws and take off the fan cover prior to cleaning the fan, fig. 20. Clean the impeller blades with a soft cloth wetted in mild water detergent solution. Avoid liquid dripping on the motor, fig. 2! After cleaning of the impeller re-install the cover and tighten the screws. The fan maintenance is allowed by a qualified expert only. Fig.18 Fig. 19 Fig. 20 Fig. 21 Fig. 22 Fig. 2 F88EN-02.indd 9 04.09.2015 8:07:17

10 VKM ЕС STORAGE REQUIREMENTS Store the fan in the manufacturer s original packing box in a dry ventilated premise at the temperatures from +5 C up to + 40 C and relative humidity less than 80% (at the temperature +20 C). Vapours or particles which can cause corrosion or damage the insulation or connection tightness are not allowed in the storage environment. MANUFACTURER S WARRANTY The fan is manufactured at the factory of Ventilation systems Pr JSC (hereinafter referred to as the Manufacturer). By purchasing this product the customer confirms to have read and agreed to the warranty terms. The manufacturing company sets forth the warranty period (service life) of the product as 24 months following the sale date via retail network subject to the customer s ensuring compliance with the rules of transportation, storage, mounting and operation of the product. In case of no confirmation of the sales date the warranty period is calculated from the manufacturing date. All the units and components belonging to the faulty unit and replaced within the warranty period shall be covered by the previous warranty period and general warranty conditions. Thus the warranty period is neither extended nor renewed for the replaced components or the unit. In case of failure due to faulty equipment during the warranty period the consumer has the right to get it exchanged at the manufacturing facility. For the product replacement please contact your Seller. The accessories operated together with the unit, both included and not included into the delivery list as well as other equipment operating jointly with the unit are not covered by the warranty. The company is not responsible for compatibility of their goods with other producers goods. The warranty covers the manufacturing defects only. All the defects and faults resulting from gross mechanical effect during operation process or natural wear-and-tear are not covered by the warranty conditions. The faults caused by violence of operation, servicing and maintenance guidelines either by Customer or third parties or caused by unauthorized design modifications shall not be covered by warranty. WARRANTY LIMITATION The manufacturer is not responsible for any mechanical or physical damages resulting from the manual requirements violence, the unit misuse or gross mechanical effect. Indirect damages such as re-installation or re-connection of the unit, direct or indirect losses related to the unit replacement shall not be indemnified. Mounting/dismantling, connection/disconnection and adjustment of the unit shall not be covered by the warranty. The contractor in charge for mounting, electric mounting and adjustment works shall be responsible for quality and warranty of these works. In any case the indemnity amount shall not exceed the actually paid value for the defective unit price. F88EN-02.indd 10 04.09.2015 8:07:17

11 ACCEPTANCE CERTIFICATE We hereby declare that the following product complies with the essential protection requirements of Electromagnetic Council Directive 2004/108/EC, 89/6/EEC and Low Voltage Directive 2006/95/EC, 7/2/ EEC and CE-marking Directive 9/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. The fan has been duly certified as serviceable: model Stamp of the acceptance inspector Date of production Sold by name of the vendor, stamp of the retailer Sale date WARRANTY CARD F88EN-02.indd 11 04.09.2015 8:07:17

F88EN-02 F88EN-02.indd 12 04.09.2015 8:07:17