Certificate of Compliance

Similar documents
Certificate of Compliance

File E Vol. 1 Sec. 93 Page 1 Issued: and Report Revised:

Certificate of Compliance

CERTIFICATE. No. P Order No Page 1/2

Laptop Computer (OLPC)

Switching power supply. Additional Information on page 2 Input rating: Vac, 50-60Hz, 2.5A Output rating: 24Vdc, 8.33A max., 200W max.

EU Declaration of Conformity

CB TEST CERTIFICATE. Personal Computer. Acer Computer (Shanghai) Limited 3F, No. 168 Xizang Medium Road Huangpu District, Shanghai CHINA

Power Supply, Built-In DC/DC. XP POWER L L C SUITE E DYER RD SANTA ANA, CA United States

DC/DC Converter. ERICSSON AB FAROGATAN 6 STOCKHOLM, SE Sweden. ERICSSON AB FAROGATAN 6 STOCKHOLM, SE Sweden

Independent controlgears

Component Switching Power Supply. XP POWER L L C Suite E DYER RD Santa Ana, CA USA

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

DIN Rail Power Supply. Refer to page 2. [8] Additional Information on page 2. Input: Vac; 12 A; 50-60Hz Output: 24 V de; 40 A

Power Supply for building-in TH-10280, THAILAND. See page 2. 0 Additional Information on page 2

Amendment to Test Report

CERTIFICATE. No. P Order No Page 1/2

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

UL TEST REPORT AND PROCEDURE

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

Test Report issued under the responsibility of:

EU Declaration of Conformity

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Provläsningsexemplar / Preview TECHNICAL REPORT. Part 3-1: Conformity verification report for IEC :2001 General requirements

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

Certificate of Compliance

ERTIFICATE. No. P This Nemko Certificate replaces the Certificate issued 27 March 2003 due to an error in the Factory listing.

LED CONVERTER. Korea, Republic of SOLUM CO., LTD. Korea, Republic of. Additional information on page 2 OLU750P701U1U; OLU750P701U1A

File E90165 Vol. 2 Index Page 1 Issued: Revised: Construction United States Type Canadian Type Section

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

UL TEST REPORT AND PROCEDURE

Certificate of Compliance

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

Certificate of Compliance

ISO INTERNATIONAL STANDARD

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements. TÜV Rheinland Shanghai Co., Ltd.

UL TEST REPORT AND PROCEDURE

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

Consumer Products Services Germany GmbH Türkheim Germany

Test Report Iec En Household And Similar

EU Declaration of Conformity

Certificate of Compliance

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C,

ENEC NO2187. Nemko hereby grants the following manufacturer as licensee the right to affix this ENEC mark on the product(s) specified below.

AS/NZS IEC :2013

Regulatory Compliance Training for Non-Safety Engineers

Certificate of Compliance

ISO 2411 INTERNATIONAL STANDARD. Rubber- or plastics-coated fabrics Determination of coating adhesion

Certificate of Compliance

INTERNATIONAL STANDARD

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)...

File E Project 97SC January 21, 1998 REPORT

ISO INTERNATIONAL STANDARD. Footwear Test methods for outsoles Tensile strength and elongation

Provläsningsexemplar / Preview TECHNICAL REPORT

ISO INTERNATIONAL STANDARD. Footwear Test methods for outsoles Tensile strength and elongation

ISO INTERNATIONAL STANDARD

Certification Supplement Manual

AS/NZS :2016

IECEE OPERATIONAL DOCUMENT

SECONDARY CELLS AND BATTERIES

ISO INTERNATIONAL STANDARD. Fire-fighting hoses Rubber and plastics suction hoses and hose assemblies

ISO 505 INTERNATIONAL STANDARD. Conveyor belts Method for the determination of the tear propagation resistance of textile conveyor belts

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

International Product Compliance and Certifications. Product Safety Consulting, Inc.

ISO INTERNATIONAL STANDARD. Non-destructive testing Penetrant testing Part 2: Testing of penetrant materials

ISO 7458 INTERNATIONAL STANDARD. Glass containers Internal pressure resistance Test methods

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

ISO INTERNATIONAL STANDARD. Agricultural engineering Electrical and electronic equipment Testing resistance to environmental conditions

HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY PART 2-13: PARTICULAR REQUIREMENTS FOR DEEP FAT FRYERS, FRYING PANS AND SIMILAR

RAILWAY APPLICATIONS - ELECTROTECHNICAL EQUIPMENT FOR ROLLING STOCK PART 5: ELECTROTECHNICAL COMPONENTS RULES FOR HV FUSES (IEC :2003)

ISO INTERNATIONAL STANDARD. Footwear Test methods for uppers and lining Water vapour permeability and absorption

ISO INTERNATIONAL STANDARD. Footwear Test methods for accessories: Touch and close fasteners Peel strength before and after repeated closing

Test Report. Appliance EMF Testing

ISO INTERNATIONAL STANDARD. Footwear Test methods for whole shoe Washability in a domestic washing machine

Certificate of Compliance

Certification Supplement Manual

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME. Additional Information on page 2.

ISO INTERNATIONAL STANDARD. Clothing for protection against infectious agents Test method for resistance to dry microbial penetration

ISO INTERNATIONAL STANDARD

PETROLEUM AND NATURAL GAS

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD

English version. Precast concrete products - Full-scale testing requirements in standards on precast concrete products

ISO INTERNATIONAL STANDARD. Footwear Test methods for outsoles Flex resistance

ISO INTERNATIONAL STANDARD. Welding Acceptance inspection of electron beam welding machines Part 4: Measurement of welding speed

Certification Supplement Manual

ISO INTERNATIONAL STANDARD. Footwear Test methods for outsoles Abrasion resistance

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00

ISO INTERNATIONAL STANDARD. Acoustics Measurement of sound pressure level from service equipment in buildings Engineering method

EU Declaration of Conformity

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

CONVENTIONS CONCERNING ELECTRIC AND MAGNETIC CIRCUITS (IEC 60375:2003) IRISH STANDARD I.S. EN 60375:2003. Price Code

This document is a preview generated by EVS

LED CONVERTER. Korea, Republic of SOLUM CO., LTD. Korea, Republic of. Additional information on page 2 OLU700P142U1A; OLU700P142U1U

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD. Plastics piping systems for hot and cold water installations Crosslinked polyethylene (PE-X) Part 1: General

PHOTOVOLTAIC DEVICES -- PART 2:

Transcription:

Certificate of Compliance Certificate: 70151027 Master Contract: 170351 (039772_0_000) Project: 70151027 Date Issued: 2017-08-14 Issued to: Bel Fuse Inc. 206 Van Vorst St Jersey City, New Jersey 07302 USA Attention: Editha S. Vergara The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Gwangyeol Park Gwangyeol Park PRODUCTS CLASS - C531111 - POWER SUPPLIES-Component Type(CSA 60950-1-07-2nd Ed) CLASS - C531191 - POWER SUPPLIES-Component Type(UL 60950-1-2nd Ed)Certified to U.S.Stds Component type power supplies intended for use with Information Technology and Business Equipment, where the suitability of the combination is to be determined by CSA Group. AC/DC Power Supply, Models PES1600-12-080NA and PES1600-12-080NAP, model number may be followed by alpha numeric characters indicating non-safety critical operations. Electrical Rating: Model PES1600-12-080NA, PES1600-12-080NAP Input Output (DC) V A Hz V A 100-127 14 50/60 V1: 12V 91.6 200-240 9.5 50/60 V1: 12V 133 V SB: 12V 3.5 Maximum operating ambient: 55 C DQD 507 Rev. 2016-02-18 Page 1

Certificate: 70151027 Project: 70151027 Master Contract: 170351 Date Issued: 2017-08-14 APPLICABLE REQUIREMENTS CAN/CSA C22.2 No. 60950-1-07 + Am1:2011 + Am2: 2014 ANSI/UL 60950-1-2014 - Information Technology Equipment - Safety - Part 1: General Requirements - Information Technology Equipment - Safety - Part 1: General Requirements DQD 507 Rev. 2016-02-18 Page 2

Supplement to Certificate of Compliance Certificate: 70151027 Master Contract: 170351 (039772_0_000) The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Project Date Description Product Certification History 70151027 2017-08-14 AC-DC Converter Model PES1600-12-080NA, PES1600-12-080NAP (CSA C/US) DQD 507 Rev. 2016-02-18 Page 1

CERTIFICATE No. P17222211 Order No. 337007 Page 1 of 1 Product Applicant Manufacturer Factory Ratings Trade mark AC-DC Converter Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ 07302 USA Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ 07302 USA BPS Asia Pacific Electronics (Shenzhen) Co., Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park, Guangming District, Shenzhen, 518108 China Input, AC: 100-127 V~, 14 A, 50/60 Hz 200-240 V~, 9.5 A, 50/60 Hz Output, DC:V1:12 V dc, 91.6 A (100-127 V~); 12 V dc, 133 A (200-240 V~). VSB:12 V dc, 3.5 A Model / Type Ref. Principal characteristics A sample of the product was tested and found to be in conformity with Validity Additional information PES1600-12-080NA, PES1600-12-080NAP (maybe followed by alphanumeric characters indicating non-safety critical options) OFF EN 60950-1:2006;A11;A1;A12;A2 This certificate documents conformity with the standards shown, and also applies as license for use of Nemkos name and certification mark. The certificate and license is valid as long as the applicable conditions are complied with, and provided that any changes to the product are notified to Nemko for acceptance prior to implementation. New standards or amendments to the standards may imply that the product design must be updated and/or that re-testing and re-certification is necessary. Additional model(s) Compliance with requirements regarding building-in, protection against electric shock and Electromagnetic Compatibility (EMC) must be checked when the equipment is built-in a completed product or forms a part of a complete system. No additional models Date of issue 14-08-2017 Jiyea Gim Certification Department Nemko AS Gaustadalléen 30, P.O. Box 73 Blindern, 0314 Oslo, Norway TEL +47 22 96 03 30 FAX +47 22 96 05 50 EMAIL info@nemko.com ENTERPRISE NUMBER NO974404532 nemko.com

Ref. Certif. No. NO98813 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME SYSTEME CEI DACCEPTATION MUTUELLE DE CERTIFICATS DESSAIS DES EQUIPEMENTS ELECTRIQUES (IECEE) METHODE OC CB TEST CERTIFICATE CERTIFICAT D'ESSAI OC Product Produit Name and address of the applicant Nom et adresse du demandeur Name and address of the manufacturer Nom et adresse du fabricant Name and address of the factory Nom et adresse de l'usine Note: When more than one factory, please report on page 2 Note: Lorsque il y plus d'une usine, veuillez utiliser la deuxième page Ratings and principal characteristics Valeurs nominales et caractéristiques principales Trademark (if any) Marque de fabrique (si elle existe) AC-DC Converter Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ 07302 USA Bel Fuse Inc. 206 Van Vorst St. Jersey City, NJ 07302 USA BPS Asia Pacific Electronics (Shenzhen) Co., Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park, Guangming District, Shenzhen, 518108 China Additional information on page 2 Input, AC: 100-127 V~, 14 A, 50/60 Hz 200-240 V~, 9.5 A, 50/60 Hz Type of Manufacturer s Testing Laboratories used Type de programme du laboratoire d essais constructeur Model / Type Ref. Ref. De type CTF Stage 2 PES1600-12-080NA, PES1600-12-080NAP Additional information (if necessary may also be reported on page 2) Les informations complémentaires (si nécessaire, peuvent être indiqués sur la deuxième page A sample of the product was tested and found to be in conformity with Un échantillon de ce produit a été essayé et a été considéré conforme à la As shown in the Test Report Ref. No. which forms part of this Certificate Comme indiqué dans le Rapport dessais numéro de référence qui constitue partie de ce Certificat Output, DC:V1:12 V dc, 91.6 A (100-127 V~); 12 V dc, 133 A (200-240 V~). VSB:12 V dc, 3.5 A (maybe followed by alphanumeric characters indicating non-safety critical options) Additional information on page 2 IEC 60950-1:2005, IEC 60950-1:2005/AMD1:2009, IEC 60950-1:2005/ AMD2:2013 337007 This CB Test Certificate is issued by the National Certification Body Ce Certificat dessai OC est établi par l'organisme National de Certification Gaustadalléen 30 NO-0373 Oslo, Norway Date: 14-08-2017 Signature: Jiyea Gim Certification Department Issued 2007-04 1/1

Test Report issued under the responsibility of www.nemko.com Report Number....: 337007 TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Date of issue...: 14 August 2017 Total number of pages...: 67 Applicant s name...: Bel Fuse Inc. Address : 206 Van Vorst St., Jersey City, NJ 07302 Test specification: Standard : IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013 Test procedure...: CB-Scheme Non-standard test method...: N/A Test Report Form No.... : IEC60950_1F Test Report Form(s) Originator...: SGS Fimko Ltd Master TRF : Dated 2014-02 Copyright 2014 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System). All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. General disclaimer: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report. This Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a laboratory having special agreement with Nemko.

Page 2 of 67 Report No. 337007 Test item description... : AC-DC Converter Trade Mark : Manufacturer...: Same as Applicant Model/Type reference...: PES1600-12-080NA, PES1600-12-080NAP (maybe followed by alphanumeric characters indicating non-safety critical options) Ratings : Input, AC: 100-127 V~, 14 A, 50/60 Hz 200-240 V~, 9.5 A, 50/60 Hz Output, DC: V1: 12 V, 91.6 A (100-127 V~); 12 V, 133 A (200-240 V~). VSB: 12 V, 3.5 A Testing procedure and testing location: CB Testing Laboratory: Nemko USA Inc. Testing location/ address... : 2210 Faraday Ave. Suite 150, Carlsbad, CA 92008, USA Testing Laboratory: CTF-2 BPS Asia Pacific Electronics (Shenzhen) Co., Ltd. Testing location/ address... : Building#6, Nanming Road, Gongming Town Huahong Xintong Industrial Park Guangming District 518108 Shenzhen PEOPLE S REPUBLIC OF CHINA Associated CB Testing Laboratory: Testing location/ address... : Tested by (name + signature)... : Reviewed by (name + signature)... : Approved by (name + signature)... : Editha Vergara Luis Gonzalez Jeff Busch TRF No. IEC60950_1F

Page 3 of 67 Report No. 337007 Report History: Original report List of Attachments (including a total number of pages in each attachment): Attachment 1: Attachment 2: European Group Differences and National Deviations for other countries Documented European deviations contain individual national documents for several European countries that are also included in the European Group Differences. Any individual national deviation that is documented twice is considered additional documentation and is included at the manufacturer s request Miscellaneous Documentation, e.g. Photos, PWB Layout, Schematic etc. (Not for publication Engineering use only) 91 pages 23 pages TRF No. IEC60950_1F

Page 4 of 67 Report No. 337007 Summary of testing General Power supply 1.1.2; The unit is intended to operate at an altitude of up to 5000m. All comments relate to all models, unless specifically stated. The equipment is an enclosed, Class I switch mode power supply with universal AC input and two DC voltage outputs for building-in. This report covers multiple models and all comments / tests apply to all models unless otherwise indicated. This equipment is intended to be operated at an altitude of up to 5000 m, so the clearance is multiplied by the altitude correction factor (1.48), specified in table A.2 of IEC 60664-1 2 nd Edition:2007-04. Refer to Tables 2.10.3 and 2.10.4. 1.5, 3.2.5; Power supply cord set. A power supply cord set is not provided with the power supply. A power supply cord set, complying with the national regulations of the country in which the product is to be sold, shall be provided with the end-use equipment. 1.7.2; Safety instructions. Instructions and equipment markings related to safety are to be provided in a language, which is acceptable in the country in which the equipment is to be sold. English language verified. 1.7.2.4; IT power distribution systems The equipment complies with the requirements for connection to the Norwegian IT power systems. The following information should be given (but is not required) in the installation instruction: This product is also designed for IT power system with Phase to Phase voltage 230V. 2.7.6; Warning to service personnel. After operation of the protective device, the equipment is still under voltage if it is connected to an IT-power system. A warning is required for service personnel. Norway does not require this warning. 5.2: Electric Strength test Increased test voltages for Basic insulation applied to the equipment, based on measured working voltages. TRF No. IEC60950_1F

Page 5 of 67 Report No. 337007 Summary of testing: Tests performed (name of test and test clause): 1) Input... 1.6.2 2) Durability... 1.7.11 3) Capacitance Discharge... 2.1.1.7 4) SELV Reliability... 2.2 5) Protective Bonding... 2.6.3.4 6) Humidity... 2.9.2 7) Working Voltage Measurement... 2.10.2 8) Hazardous Voltage Measurement... 2.10.2 9) Mechanical and Stress Relief Test... 4.2 10) Handle Test... 4.3.2 11) Connection by Plugs and Sockets Current Interruption Test... 4.3.5 12) Heating... 4.5.1 13) Touch Current... 5.1 14) Electric Strength... 5.2.2 15) Component Failure... 5.3 16) Abnormal Operation... 5.3 17) PSU Output Overload and Short... 5.3 18) Transformer Overload and Insulation... Annex C Testing location: BPS Asia Pacific Electronics (Shenzhen) Co., Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park Guangming District 518108 Shenzhen PEOPLE'S REPUBLIC OF CHINA Summary of compliance with National Differences: List of countries addressed: Austria (AT), Australia (AU), Canada (CA), China (CH), Denmark (DK), Finland (FI), Germany (DE), Ireland (IE), Israel (IS), Japan (JP),Korea (KR), Norway (NO), Singapore (SG),Slovenia (SI), Spain (ES), Sweden (SE), Switzerland (CH), United Kingdom (GB), Ukraine (UA), and United States of America (US) The product fulfils the requirements of : EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 TRF No. IEC60950_1F

Page 6 of 67 Report No. 337007 Copy of marking plate: The artwork may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks. (Additional requirements for markings. See 1.7 NOTE) Calibration Measurement uncertainty Evaluation of results All instruments used in the tests given in this test report are calibrated and traceable to national or international standards. Further information about traceability will be given on request. Measurement uncertainties are calculated for all instruments and instrument set-ups given in this report. Calculations are based on the principles given in the standard EA-4/02 (Dec. 1999), IEC Guide 115:2007. Further information about measurement uncertainties will be given on request. If not explicitly stated otherwise in the standard, the test is passed if the measured value is equal to or below (above) the limit line, regardless of the measurement uncertainty. If the measured value is above (below) the limit line, the test is not passed - ref IEC Guide 115:2007. The instrumentation accuracy is within limits agreed by IECEE-CTL. TRF No. IEC60950_1F

Page 7 of 67 Report No. 337007 Test item particulars: Equipment mobility... : [] movable [] hand-held [] transportable [] stationary [ X ] for building-in [] direct plug-in Connection to the mains...: [ X ] pluggable equipment [ X ] type A [] type B [] permanent connection [] detachable power supply cord [] non-detachable power supply cord [] not directly connected to the mains Operating condition...: [ X ] continuous [] rated operating / resting time: Access location...: [] operator accessible [] restricted access location Over voltage category (OVC)...: [] OVC I [ X ] OVC II [] OVC III [] OVC IV [] other: Mains supply tolerance (%) or absolute mains supply values : -10%, +10% Tested for IT power systems...: [ X ] Yes (Norway only) [ ] No IT testing, phase-phase voltage (V)...: 230 Class of equipment...: [ X ] Class I [] Class II [] Class III [] Not classified Considered current rating of protective device as part of the building installation (A)... : 16 A for Europe, 20 A for North America, 40A maximum ( per manufcaturer s specifications) Pollution degree (PD)...: [] PD 1 [ X ] PD 2 [] PD 3 IP protection class...: IP 20 Temperature, Ambient ( C)...: 55 C Relative Humidity (RH)...: 10% to 85% RH Altitude during operation (m)...: 5000 m Altitude of test laboratory (m)...: 38 m Mass of equipment (kg)...: 0.97 kg Possible test case verdicts: - test case does not apply to the test object... : N/A - test object does meet the requirement... : P (Pass) - test object does not meet the requirement... : F (Fail) Testing: Date of receipt of test item... : June 2017 Date(s) of performance of tests... : July 2017 TRF No. IEC60950_1F

Page 8 of 67 Report No. 337007 General remarks: "(see appended table)" refers to a table appended to the report. "(see Enclosure #)" refers to additional information appended to the report. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. Throughout this report a comma / point is used as the decimal separator. Manufacturer s Declaration per sub-clause 4.2.5 of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided... Yes Not applicable When differences exist; they shall be identified in the General product information section. Name and address of factory (ies)... : BPS Asia Pacific Electronics (Shenzhen) Co.,Ltd. Building# 6, Nanming Road, Gongming Town Huahong Xintong Industrial Park Guangming District 518108 Shenzhen PEOPLE'S REPUBLIC OF CHINA General product information: The subject models are component type AC-DC power supplies, intended for building-in, and provided with metal enclosure. The units have two outputs: V1: 12VDC and VSB: 12VDC. The following PWB assemblies are provided: Main, Control, Inlet and Card edge PWB. The main PWB is stalled on chassis stand offs by screws. Control PWB and Inlet PWB are mounted vertically on the main PWB through multi-pin connectors, Card edge PWB is mounted also on the main PWB through multi-pin connector close to output. The units are provided with AC inlet, fan, insulators and LED indicators. The fan is installed at bracket of main PWB close to front panel, air flow from rear to front panel; Insulating foil is provided between PWB assemblies and enclosure. The LED indicators are installed on the front panel. The following isolating transformers are mounted on main PWB, including gate driver transformer T1, auxiliary transformer T3 (Class B) and main transformer T2 (Class F). Model differences: Model PES1600-12-080NA is base model. Model PES1600-12-080NAP is exactly same as PES1600-12-080NA except for AC Inlet type. PES1600-12- 080NAP has C22 type AC inlet while PES1600-12-080NA uses C20 AC inlet. TRF No. IEC60950_1F

Page 9 of 67 Report No. 337007 Conditions of Acceptability: The following must be evaluated at end use: 1) The power supply is to be installed only by trained service personnel. 2) Evaluated as Class I (earthed equipment). Reliable earth connection shall be provided in the end use installation. Limited short-circuit test with 1500A test current has been conducted on the PWB GND trace from AC inlet pin to chassis. 3) Evaluated for use in a Pollution Degree 2 environment, up to 5000 m altitude, 55 C ambient. Temperature tests shall be considered for specific installation conditions in the end system. 4) A suitable Electrical and Fire Enclosure shall be provided on rear side of the power supply. Front panel has been evaluated and meets fire, electrical and mechanical enclosure. 5) All secondary output circuits are SELV. 6) Secondary V1: 12V output is at Hazardous energy level. 7) The output connector has not been evaluated for field wiring. 8) The Connector Current Interruption Test was performed on the output connector for 200 cycles (insertion/withdrawal). Testing for additional cycles shall be determined during the end product evaluation, depending on end product application. 9) The equipment was tested on a listed 40 A branch circuit. If used on a branch circuit greater than this, additional testing may be necessary. Abbreviations used in the report: - normal conditions... N.C. - single fault conditions... S.F.C - functional insulation... OP - basic insulation... BI - double insulation... DI - supplementary insulation... SI - between parts of opposite polarity... BOP - reinforced insulation... RI Indicate used abbreviations (if any):... None TRF No. IEC60950_1F