PRODUCT DATA NILAIR BY NILAN Air distribution Domestic Ventilation
NILAIR NilAIR is installed together with a ventilation unit,which in simple terms consists of distribution boxes from which tubes are led out to air extraction and air supply boxes in the individual rooms. NilAIR can be installed in ceilings, walls or floors. The lightweight tubes can be used for even the most complicated tube alignments, where e.g. traditional spiral ducts cannot be used. Advantages Enabling the impossible Flexible and space-saving solution Rapid and simple installation with a click system Dimensionally stable and corrosion-resistant quality material Simple regulation of the air supply volume Low weight High impermeability Easy to clean Easy to handle and transport Prevents sound travelling from room to room Traditional air distribution systems take up a lot of space and often make special building structures impossible. NilAIR virtually eliminates this problem, due to the tubes size and flexibility. NilAIR is already installed in thousands of European homes and since its introduction more than ten years ago its use has steadily increased, due to the rapid and easy installation without any special tools being required. Installation examples 2
NILAIR PRINCIPLE NILAIR BY NILAN Air extraction (mounted in wall or ceiling) Kitchen Ventilation unit Utility room Bathroom Bathroom Distribution manifold extract air (mounted in floor or ceiling) Soundflex Distribution manifold supply air (mounted in floor or ceiling) Living room Room Room Family room Bedroom Air supply (mounted in floor, wall or ceiling) 3
TUBE Use Advantages A flexible solution to carry the supply air and extract air around the home. The tubes are developed especially for ventilation systems and can be installed in various different building components, such as: Insulation layer The cast concrete floors or concrete ceilings Above suspended ceilings Under floors with sufficient space to carry the tubes The tubes present many advantages compared to the traditional spiral duct solution. Installation does not take a lot of time, no need for special tools such as a grinder, and the tubes are easy to install in confined spaces. This flexibility means that the tubes can be used in many situations where traditional ducts cannot be used, due to the confined space and narrow ducting routes. Smooth inside - minimising resistance and facilitating cleaning Reinforced corrugated exterior (STIS > 12.0 kn/m 2 in accordance with EN ISO 9969 SN 12) Easy to hide in the existing insulation (no extra insulation) Bendable - not necessary to buy bends and T-sections Sound-absorbing - no need to install extra sound absorbers between each room *The sound-absorbing of telephony is more than 50 db at an oktave band medium frekvenz of 00 Hz. Testet according to ISO 3741 and EN ISO9614-1 Material Clean PE-HD PE is classified as non-hazardous to health. In accordance with 1999/45/ EG the tubes are free of hazardous substances. The tubes can be bent to the following radius: Ø75 mm: 27 cm Ø90 mm: 30 cm Sizes: Ø75 mm - blue Ø90 mm - green (sold in lengths of 50 m) Pressure loss per meter Pa 9 8 7 Tube Ø75 mm 6 Tube Ø90 mm 5 4 3 2 1 0 0 30 40 50 60 70 80 90 2 4 6 8 12 14 16 18 22 24 4
UNIQUE CLICK SYSTEM NILAIR BY NILAN Rapid installation Thanks to the unique, patented NilAIR click system, all tubes in the air distribution system can be mounted without using tools, due to the special design of the connectors on the distribution, extract and supply air boxes. The connectors are designed to match both Ø75 mm og Ø90 mm tubes. Installation of NilAIR Ø75 mm tube There is a clamp ring on the connectors. When the tube has been pushed in and locked by the grips in the connector (A), the clamp ring is pushed into place (B), which ensures a stable, sealed join. Installation of NilAIR Ø90 mm tube Lay a silicon sealing joint in the connecting pipe. Push the hose into the connecting pipe. Lock the hose in place using the barbs on the connecting pipe. The joint is now stable and watertight. 5
DISTRIBUTION MANIFOLD Unibox Sizes The distribution manifold gather the tubes with supply and extract air and carry the air to and from the ventilation unit. For use in single-family home, oblong distribution manifold with 8 or 12 connectors are recommended. The connection between the unit and the distribution box can be made using a Soundflex connector. Soundflex is a flexible connector with thermal and sound absorbent insulation (read more on page 18). The manifolds are insulated with 25-mm sound-insulating material to ensure a quiet transition to the tubes. The distribution manifold can be mounted from ceilings, above suspended ceilings, or in floors under concrete decks. The connectors that are not used are sealed off with a cover. Material 0,9 mm Aluzinc steel plate Insulation 25 mm sound and condensateinsulation Connectors Pure PE-HD Either left or right version of Unibox can be used. Screw off the connecting pipe and cover plate. Switch them around and replace. 290 Ø 160 290 Ø 160 95 95 770 1270 Left Right Unibox 8 connectors - Art.no. DK4018 (up to 240 m 3 /h) Unibox 12 connectors - Art.no. DK401212 (up to 360 m 3 /h) Pressure loss supply air Pressure loss extract air 50 Pa 50 Pa Pressure loss supply air 40 30 Pressure loss extract air 40 30 0 0 50 0 150 0 250 30 40 50 60 0 0 50 0 150 0 250 30 40 50 60 Air volume Air volume Unibox8 connectors - Art.no. DK4018 Unibox 12 connectors - Art.no. DK401212 6
DISTRIBUTION MANIFOLD NILAIR BY NILAN Combox Sizes The distribution manifold gather the tubes with supply and extract air and carry the air to and from the ventilation unit. The connection between the unit and the distribution box can be made using a Soundflex connector. Soundflex is a flexible connector with thermal and sound absorbent insulation (read more on page 18). For use in flats, are distribution manifold with 6 or connectors available. For larger projects, the distribution box can be adapted to each project. The connectors that are not used are sealed off with a cover. The manifolds are insulated with 25-mm sound-insulating material to ensure a quiet transition to the tubes. The distribution manifold can be mounted from the ceiling. Material Insulation Connectors 0,9 mm Aluzinc steel plate 25 mm sound and condensateinsulation Pure PE-HD Ø125 80 81 161 39 500 656 Ø160 140 600 696 330 300 330 5 5 5 5 5 150 150 150 75 Combox 6 connectors - Art.no. 85285 (up to 180 m 3 /h) Combox connectors - Art.no. DK43 (up to 300 m 3 /h) Pressure loss supply air Pressure loss extract air Pa Pa 50 50 45 45 Pressure loss supply air 40 35 30 25 15 Pressure loss extract air 40 35 30 25 15 5 5 0 0 50 0 150 0 250 300 350 400 0 0 50 0 150 0 250 300 350 400 30 40 50 60 70 80 90 0 30 40 50 60 70 80 90 0 Air volume Air volume Combox 6 connectors - Art.no. 85285 Combox connectors - Art.no. DK43 7
SUPPLY AIR BOXES LOW FOR GRID Use Supply air boxes for grille can be mounted in ceilings, walls or floors. Can be ordered with 1, 2 or 3 connectors, depending on the air volume required. Suitable for both Ø75 mm og Ø90 mm tube. Material Connectors Grille sizes Grille sizes 0,9 mm Aluzinc steel plate Pure PE-HD 1 connector (300 x 50 mm) 2 or 3 connectors (500 x 50 mm) A regulation element may be mounted to regulate the supply air volume in the individual box. The regulation element has seven settings and can be set by turning and clicking the inner element. (page 19) 0 315 95 23-30 0 514 95 23-30 0 514 95 23-30 0 150 150 1 connector - Art.no. DK409001 2 connectors - Art.no. DK409002 3 connectors - Art.no. DK409003 Pressure loss Pa 18 Pressure loss supply air 16 14 12 8 6 4 2 1 connector 2 connectors 3 connectors 0 0 30 40 50 60 70 80 90 0 5 15 25 Air volume 8
SUPPLY AIR BOXES HIGH FOR GRID NILAIR BY NILAN Use Supply air boxes for grille can be mounted in ceilings, walls or floors. May be ordered with 1, 2 or 3 connectors, depending on the air volume required. Suitable for both Ø75 mm og Ø90 mm tube. Material Connectors Grille sizes Grille sizes 0,9 mm Aluzinc steel plate Pure PE-HD 1 connector (300 x 50 mm) 2 or 3 connectors (500 x 50 mm) The size matches a brick section for mounting in a brick wall. The robust materials make them suitable for embedding without any risk of deformation. An adjustment component for grille box may be mounted to regulate the air supply volume in the individual box. The regulation element has seven settings and can be set by turning and clicking the inner element. (page 19) 312 512 512 16-80 180 16-80 180 150 150 16-80 180 69 0 69 69 1 connector - Art.no. DK408001 2 connectors - Art.no. DK408002 3 connectors - Art.no. DK408003 Pressure loss 18 Pa Pressure loss supply air 16 14 12 8 6 4 2 1 connector 2 connectors 3 connectors 0 0 30 40 50 60 70 80 90 0 5 15 25 Air volume 9
SUPPLY AIR BOXES FOR VALVE Use Supply air boxes for mounting of valves for the supply air into a room. The valves are available in white-painted metal (page 14). For ceiling or wall mounting. Can be ordered with 1, 2 or 3 connectors, depending on required volume. Material Connectors Valve for 1 or 2 connectors Valve for 3 connectors 0,9 mm Aluzinc steel plate Pure PE-HD Ø0 mm Ø125 mm Suitable for both Ø75 mm and Ø90 mm tubes. 0 0 Ø0 315 0 Ø0 315 Ø125 515 95 95 95 1 150 150 1 connector - Art.no. DK4101 2 connectors - Art.no. DK4102 3 connectors - Art.no. DK4103 Pressure loss 18 Pa Pressure loss supply air 16 14 12 8 6 4 2 1 connector 2 connectors 3 connectors 0 0 30 40 50 60 70 80 90 0 5 15 25 Air volume
EXTRACT AIR BOXES FOR VALVEL NILAIR BY NILAN Use Extract air boxes for mounting of valves for air extraction from rooms exposed to moisture. The valves are available in whitepainted metal (page 14). For ceiling or wall mounting. Can be ordered with 1, 2 or 3 connectors, depending on required volume. Material Connectors Valve for 1 or 2 connectors Valve for 3 connectors 0,9 mm Aluzinc steel plate Pure PE-HD Ø0 mm Ø125 mm Suitable for both Ø75 mm and Ø90 mm tubes. 0 0 Ø0 315 0 Ø0 315 Ø125 515 95 95 95 1 150 150 1 connector - Art.no. DK4101 2 connectors - Art.no. DK4102 3 connectors - Art.no. DK4103 Pressure loss 18 Pa Pressure loss extract air 16 14 12 8 6 4 2 1 connector 2 connectors 3 connectors 0 0 30 40 50 60 70 80 90 0 5 15 25 Air volume 11
SUPPLY AIR BOXES FOR VALVE ABOVE DOOR Use Supply air boxes for mounting of valves to the supply air above a door. For wall-mounting. Can be ordered with 2 or 3 connectors, depending on required volume. Material Connectors Valve 0,9 mm Aluzinc steel plate Pure PE-HD Ø125 mm Suitable for both Ø75 mm and Ø90 mm tubes. 340 340 86 84 59 111 150 75 75 Ø125 176 62 62 Ø125 300 300 114 83 87 300 300 114 83 87 38 38 2 connectors - Art.no. 85284 3 connectors - Art.no. 85283 Pressure loss Pa 2,5 Pressure loss supply air 2,0 1,5 1,0 0,5 2 connectors 3 connectors 0,0 0 30 40 50 60 70 80 90 0 5 15 25 Air volume 12
EXTRACT AIR BOXES FOR VALVE ABOVE DOOR NILAIR BY NILAN Use Extract air boxes for mounting of valves to extract air above a door. For wall-mounting. Can be ordered with 2 or 3 connectors, depending on the air volume required. Suitable for both Ø75 mm and Ø90 mm tubes. Materiale 0,9 mm galvaniseret stål Stutse Pure PE-HD Ventil Ø125 mm The box may also be installed after an EM-box. In this way, tubes for extracted air can be connected to the system. 340 340 86 84 59 111 150 75 75 Ø125 176 62 62 Ø125 300 300 114 83 87 300 300 114 83 87 38 38 2 connectors - Art.no. 85284 3 connectors - Art.no. 85283 Pressure loss Pa 40 35 Pressure loss extract air 30 25 15 2 connectors 3 connectors 5 0 0 30 40 50 60 70 80 90 0 5 15 25 Air volume 13
VALVES Discreet valves NilAIR valves are barely visible in the room. They have a low height, thus giving a good quanda effect. The KIR model makes it possible to determine the supply air direction, thereby avoiding draughts at exposed points. The valves are mounted in the supply or extract air boxes (pages to 13) in both ceiling and wall. Material Steel, white powder coating RAL 90 Sizes Ø0 mm and Ø125 mm Valve frame Attached KU - Extraction valve Ø0 mm - Art.no. 86891 p t, Pa 300 0 - -8-5 0 5 ( r ) 45 28 0 35 30 99 125 137 50 25 L p A, db(a) 2 3 5 50 8 11 18 36 72 180 Ø125 mm - Art.no. 86911 p t, Pa 300 0-17 -15-12 -9-6 -3 0-3 ( r ) 6 9 45 29 0 35 30 124 150 164 50 25 L p A, db(a) 3 5 50 0 11 18 36 72 180 360 14
NILAIR BY NILAN KI - Air supply valve Ø0 mm - Art.no. 86591 p t, Pa 300 0 1,0-3 -2 0 2 4 1,5 2,0 ( r ) 6 8 L 0,2, m 45 28 0 50 35 30 KIR - Air supply valve With a sector plate for directional air supply. 124 99 124 99 50 125 125 137 Ø125 mm - Art.no. 86611 45 29 150 150 164 Ø0 mm - Art.no. 8675 (r) 17 67 Ø125 mm - Art.no. 8677 (r) 173 143 25 2 3 5 50 8 11 18 36 72 180 p t, Pa -7-3 0 3 300 4,0 3,0 0 L 0,2, m 2,0 0 50 35 30 25 L p A, db(a) p t, Pa 2 4 6 (r) 150 3 4 5 9 0 12 2 15 L 0,2, m 35 50 1,5 30 25 1 5 30 15 30 40 50 60 0 L PA, (dba) p t, Pa 4 6 9 (r) 150 12 15 4 3 0 L 35 0,2, m 50 2 30 25 1,5 L PA, (dba) L p A, db(a) ( r ) 9 12 15 5 50 0 18 36 72 180 360 50 18 8 50 76 30 40 50 60 70 0 180 15
GRILLES Elegant grilles The elegant latticed air injection grids emphasise the home s stylish architecture with a modern ventilation system. The grid is mounted in the supply air boxes (pages 8 and 9) in ceiling, wall or floor. The air supply grilles are available in two qualities: Elegance and basic. Elegance The supply air grille has a 2 mm high and 15 mm wide frame with a straight edge. Material For Grille with 1 connection For Grille with 2 or 3 connections Silver-anodised aluminium 300 x 50 mm 500 x 50 mm Art.no: W043001 Elegance Silver-anodised (300 x 50 mm) Art.no.: W045001 Silver-anodised (500 x 50 mm) Dimensional drawing 16
NILAIR BY NILAN Basic The supply air grille has a 4 mm high and mm wide frame with a round off edge. Material Silver-anodised aluminium Basic white White powder coating RAL 90 For Grille with 1 connection For Grille with 2 or 3 connections 300 x 50 mm 500 x 50 mm Art.no: W043002 Basic Silver-anodised (300 x 50 mm) Art.no: W045003 Basic Silver-anodised (500 x 50 mm) Art.no: W043003 Basic white (300 x 50 mm) Art.no: W045004 Basic white (500 x 50 mm) Dimensional drawing 17
SOUNDFLEX Flexible silencing Flexible duct connection, with thermal-acoustic insulation. A simpel and easy connection between the unit and distribution manifolds. Is also useable between the unit and discharge air and outdoor air intake. The perforated internal duct allows the insulating layer to damp and absorb the noise created in ventilation units. A protection film covers the insulating mat to avoid its erosion. Furthermore it limits the thermal exchange between the carried air and the external environment and avoids the formation of condensate during cooling. Construction Internal duct Anti erosion barrier Spiral Insulating material External duct Perforated laminated aluminium-polyester Closed polyester film Harmonic wire pitch 36 mm glass wool thick 25 mm, density 16 kg/m 3 Laminated aluminium-polyester, reinforced with glass fibre Sizes Ø0 mm (length 6 m) - Art.no. 854801 Ø125 mm (length 6 m) - Art.no. 8551 Ø160 mm (length 8 m) - Art.no. 855301 Ø0 mm (length 6 m) - Art.no. 855401 Silencing (db) 1 m tube Characteristics Operating temperature -30 / 140 C Max. pressure 2500 Pa Max. velocity 30 m/s Min. bending radius 25 + (0,54 x Ø) mm Meets all demands according to EN 13180 Hz Ø0 Ø125 Ø160 Ø0 125 9 12 17 7 250 19 22 15 500 32 21 22 17 1.000 37 25 27 2.000 31 29 19 16 4.000 21 17 14 13 Pressure loss per meter Silencing (db) 2 m tube Hz Ø0 Ø125 Ø160 Ø0,0 Pa/m Ø0 mm Ø125 mm Ø160 mm 125 19 17 31 250 33 31 39 34 5,0 2,0 6 m/s 5 m/s Ø0 mm 4 m/s 500 52 44 34 32 1.000 53 45 38 35 2.000 49 46 31 30 4.000 36 26 22 1,0 0,5 0,2 3 m/s 2 m/s Silencing (db) 3 m tube Hz Ø0 Ø125 Ø160 Ø0 125 25 23 29 18 250 39 46 43 40 500 50 44 41 38 0,1 50 0 0 500 5 30 55 135 1.000 52 47 46 41 2.000 54 51 39 39 4.000 40 34 27 30 18
ACCESSORIES NILAIR BY NILAN End cap To seal any unused connectors in the distribution box. The cover can also be used to protect from building dust and rain water when mounted on tubes or distribution boxes. Art.no. W429090 Duct-to-duct connector Used to connect tubes, in the cases where there is a need to extend a tube. Ø75 mm - Art.no. W4401 Ø90 mm - Art.no. W5401 Adjustment component for grille box Regulation of the air volume, with 7 settings. Primarily used in boxes for grilles. Art.no. W0410 19
Info: EM-BOX Use The EM-box can be connected to Nilan s ventilation units. An EMbox enables heat recovery via the home s cooker hood, utilising the heat generated from cooking. When the cooker hood is switched off, the basic ventilation takes place via the hood. When more powerful extraction is needed, e.g. during cooking, a damper in the hood is opened. At the same time, the damper in the EM-box will regulate the air extraction from other rooms as a part of the basic ventilation, so that the primary air extraction takes place via the hood. If a larger air volume is needed for the hood to provide effective extraction, the ventilation unit will increase the air volume. When the hood is switched off, ventilation will return to normal operation. The EM-box can be placed above the extraction hood, or at any point between the aggregate and hood. Material 0,9 mm Aluzinc steel plate Weight 6 kg Filter class Metal grease filter Duct connections 2 x Ø160 mm og 2 x Ø125 mm Supply voltage 230V Range hood filter box If the EM box cannot be optimally located, a range hood filter box can be used instead. The range hood filter box takes up less space and can be located adjacent to the hood. The range hood filter box includes a DTBU damper that is placed in the extraction duct leading from the hood. Dimensional drawing All dimensions are in mm. EM-box Ø160 240 Filter låg 242 mm Filter låg 394 mm 2 750 Ø125 Flytbar stuts Ø160 Range hood filter box
NILAIR BY NILAN Schematic diagrams EM-box Discharge air Fresh air The servomotor is controlled by the ventilation unit. Is activated when the extraction hood is activated. The damper control the extraction from the bathroom and utility room while the hood is running. Ventilation unit Extract air EM-box Grease filter Supply air Bathroom Utillity room Heating surface (if mounted) Basic ventilation Basic ventilation Forced operation on hood operation Forced operation distributed on rooms Range hood filter box Discharge air Fresh air On normal operation the DTBU damper is fully open and the hood is part of the ventilation system, providing basic ventilation. Ventilation unit Extract air Supply air The hood filter box protects the unit against grease Bathroom Utillity room Heating surface (if mounted) Cooker hood gives signal to the ventilation unit. On normal operation the DTBU damper is fully open and the hood is part of the ventilation system, providing basic ventilation. When the hood is in forced operation the aggregate runs up in both air injection and extraction. The DTBU dampercontrol the extraction from the bathroom and utility room while the hood is running. Basic ventilation Forced operation distributed on rooms Basic ventilation Forced operation on hood operation 21
INSTALLATION EXAMPLES One storey house A one storey family house with Comfort 300 ventilation unit mounted with NilAIR air distribution system. The air distribution are mounted in the ceiling. Scan the QR-code to view an animation of NilAIR used in a one storey house. Two storey house A two storey family house with Compact P ventilatio nunit mounted with NilAIR air distribution system. The air distribution are mounted in the storey of the building. Scan the QR-code to view an animation of NilAIR used in a two storey house. Appartment An appartment with Comfort 300 Top ventilation unit mounted with EM-box and NilAIR air distribution system. The air distributions are mounted in the ceiling. Scan the QR-code to view an animation of NilAIR used in an appartment 22
PLANNING NILAIR BY NILAN NilAIR drawing Nilan offers to provide drawings of the ventilation system installed in a one or two-storey house. A minimal fee is charged for this service. The drawing gives the installer a clear overview of the location of the various supply and extract air valves and grilles, and the NilAIR tubes. Once the drawing is approved, a part list is supplied. 23
INFORMATION FROM A TO Z Nilan develops and manufactures premium-quality, energy-saving ventilation and heat pump solutions that provide a healthy indoor climate and low-level energy consumption with the greatest consideration for the environment. In order to facilitate each step in the construction process from choosing the solution through to planning, installation and maintenance we have created a series of information material which is available for download at www.nilan.dk. Brochure General information about the solution and its benefits. WWW.NILAN.DK Nilan A/S Nilanvej 2 8722 Hedensted DEnmark Tel. +45 76 75 25 00 Fax +45 76 75 25 25 nilan@nilan.dk www.nilan.dk Product data Technical information to ensure correct choice of solution. Installation instructions Detailed guide for installation and initial adjustment of the solution. Visit us at www.nilan.dk to find out User manual Detailed guide for regulation of the solution to ensure optimum day-to-day operation. more about our company and solutions, download further information and find your nearest dealer. Drawings Tender documents and 3D drawings are available to download for planning purposes. Ver. 2.0-14.11 Nilan A/S påtager sig intet ansvar for eventuelle fejl og mangler i trykt informationsmateriale eller for tab eller skader som følge af det publicerede materiale, hvad enten dette skyldes fejl eller uhensigtsmæssigheder i materialet eller andre årsager. Nilan A/S forbeholder sig ret til uden forudgående varsel at foretage ændringer af produkter og informationsmaterialer. Alle varemærker tilhører Nilan A/S, og alle rettigheder forbeholdes.