GARCIA GALUSKA DESOUSA Consulting Engineers

Similar documents
ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

Construction Management at Risk Services. New North East Branch Library Project. August 3, 2018

RFP Addendum 2 March 31, 2016

SECTION INTRUSION DETECTION

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003

Michigan State University DESIGN GUIDELINES. ELECTRICAL DESIGN Page 1 TABLE OF CONTENTS 1

SECTION LIGHTING CONTROLS

Electronic Safety and Security

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

FIRE ALARM: BY OTHERS, IF REQUIRED.

AMENDMENT NO.: III INVITATION FOR BID NO.: GPA FOR

Technical Report Two

FIRE ALARM: BY OTHERS, IF REQUIRED.

Florence High School / Middle School Page 1 of 3 Florence, WI

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Functional Performance Test

Electrical Design Guidelines Table of Contents

ONYX FirstVision Specification Interactive Firefighters Display

F. GENERAL REQUIREMENTS Electrical Design Criteria 2006 Edition 4/3/06 School District Palm Beach County Page-1 of 15

F. GENERAL REQUIREMENTS Electrical Design Criteria 2009 Edition 11/23/2009 School District Palm Beach County Page-1 of 17

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

LIGHTING CONTROLS

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Lindsay Frederick. Lighting + Electrical. Ron Dodson Faculty Advisor. Native American Cultural Center Arizona. Technical Report 2

Section PERIMETER SECURITY SYSTEMS

Sprinkler: The building does not have a fire protection system installed. MECHANICAL / PLUMBING / SPRINKLER SYSTEMS RECOMMENDATIONS

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

A. Drawings and general provisions of Contract, including General and Supplementary Conditions apply to work of this section.

Replacement of Fire Pump and Generator Upgrade, H Building, Sexton Campus

NYC Department of Education

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

NYC Department of Education

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

DIVISION 14 - CONVEYING SYSTEMS. 1. Passenger Elevators 2. Vertical Platform and Inclined Wheelchair Lifts.

A. This Section includes the following lighting control devices:

SECTION EXTERIOR LIGHTING

FIRE & LIFE SAFTEY STANDARD

ENGINE GENERATORS AND ACCESSORIES

Renovate MCRC Facilities Great Lakes, IL

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

Library stacks and records storage 150 LB/SF live load

School Fire Safety Checklist

The following information shall become and form part of the contract documents.

NYC Department of Education

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

NYC Department of Education

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

MANUAL OF DESIGN CRITERIA AND SPECIFICATIONS FOR FIRE DETECTION AND ALARM SYSTEMS PUBLIC SCHOOLS IN NEW MEXICO

SECTION : FIRE ALARM & DETECTION SYSTEMS

.2 Section Waste Management and Disposal..4 Section Electrical General Requirements.

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1

SECTION INTRUSION DETECTION SYSTEM

Electrical Inspection Special Electrical

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM

NYC Department of Education

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram

Fire Alarm System Fundamentals

ELECTRICAL DESIGN GUIDELINES SECTION GUIDELINE SPECIFICATIONS-DUVAL COUNTY PUBLIC SCHOOL

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPUSLE VALVE, Fike FK AGENT & SHP PRO CONTROL PANEL

University Design Standard Fire Alarm Systems

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.


Appendix B. Facilities Assessment Report

Attendees/Absentees. Derek Gallagher DG. Delano Secondary School Additions and Renovations June 6, 2016 Technology User Group Meeting Minutes

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

Florida Building Code 2010

PLAN REVIEW SUBMITTAL GUIDE

Physical and Environmental Security. CISSP Guide to Security Essentials Chapter 8

NYC Department of Education

Lord Stirling Community School Electrical Systems Existing Conditions & Building Load Summary Technical Assingment#2 Due October 26, 2004

NYC Department of Education

A. This Section includes the following lighting control devices:

DONALD H. BERG, ARCHITECT

Page 1 of General

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

GARCIA GALUSKA DESOUSA Consulting Engineers

SECTION GENERATOR PARALLELING CONTROLS

SECTION DIGITAL-NETWORKING LIGHTING CONTROLS ENLIGHTED LIGHT MANAGEMENT SYSTEM

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

ELECTRICAL DESIGN BRIEF

TONY ESPOSITO LIGHTING/ELECTRICAL TECHNICAL REPORT II SEPTEMBER 15, 2011 HUNTER S POINT SOUTH INTERMEDIATE SCHOOL AND HIGH SCHOOL QUEENS, NY

SPACE TYPE: JUDICIAL CHAMBER

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

B. After installation, the Owner shall be able to perform hardware configuration changes as desired without the services of the Integrator.

Electrical System (N) PANELBOARD "L1" VOLTAGE: 208/120 A, 3P :MAIN C/B PHASE: 3 A :BUSSING WIRE: 4 :MOUNTING

PLATTEVILLE MIDDLE SCHOOL

Transcription:

L#57297 /Page 1/July 21, 2017 ELECTRICAL SYSTEMS NARRATIVE REPORT The following is the Electrical Systems narrative, which defines the scope of work and capacities of the Power and Lighting systems, as well as, the Basis of Design for the Town Hall. The Electrical systems will be designed and constructed to comply with LEED standards. 1. CODES All work installed under Section 26 00 00 shall comply with the Massachusetts State Building Code and all state, county, and federal codes, laws, statutes, and authorities having jurisdiction. 2. DESIGN INTENT All work is new and consists of furnishing all materials, equipment, labor, transportation, facilities, and all operations and adjustments required for the complete and operating installation of the electrical work and all items incidental thereto, including commissioning and testing. Capacities of systems and equipment are as specified on the drawings and schedules. A. Electrical Distribution System: Electrical power will be brought into the site via underground medium voltage cables from the utility company network. A pad mounted step-down transformer will be located at grade adjacent to the building. Service entrance and distribution switchgear will be located in the electrical room, along with lighting, power distribution, and mechanical equipment panels. The service capacity will be sized for 1200 amperes at 120/208V, 3Ø, and 4 wire. B. Emergency Power System: A natural gas powered 125KW emergency generator will be provided with sound attenuating weather proof enclosure, critical grade exhaust silencer, and automatic starting and safety controls. The generator will include two (2) service breakers: one (1) for life safety equipment and one (1) for optional standby equipment. The emergency power distribution system will consist of two (2) automatic transfer switches, one for life safety equipment and one for optional stand-by systems. A separate system of distribution panels and conduit systems will be provided for each level of emergency or standby power.

L#57297 /Page 2/July 21, 2017 C. Interior Lighting System: Lighting for General offices and meeting rooms will consist of a combination of pendant mounted direct/indirect and recessed 2 x4 LED luminaries with dimming drivers. The fixtures will be wired for automatic dimming where natural day light is available and also for multi-level switching. Lighting in meeting rooms will also consist of recessed down lights with LEDs and dimmable drivers for a multifunctional space. Corridors and other functional lighting fixtures will consist of acrylic recessed direct fixtures with LEDs and dimmable drivers. Storage and mechanical spaces will be provided with LED industrial wraparound fixtures with acrylic lens, with Electronic drivers. Exit signs will be of the energy efficient, long life LED type. All fixtures will be provided with dimmable drivers and LED lamps. Each area will be locally switched and designed for multi-level controls. Each office space and toilet room will have an occupancy sensor to turn lights off when unoccupied. The entire facility will be controlled with an addressable networked automatic lighting control system for programming lights on and off. Stage and auditorium theatrical lights with connector strips and a dimming system will be provided for performances. House lighting in auditorium will be dimmable LED and controlled by theatrical dimming system. D. Site Lighting System: Fixtures for area lighting will be pole mounted LED luminaries in the parking area and roadways. The exterior lighting will be controlled by photocell on and schedule timed off operation. Building perimeter fixtures will be wall mounted LED luminaries over exterior doors. All fixtures will be of the dark sky compliant, cut-off type. E. Wiring Devices: Offices will generally have one (1) duplex outlet per wall. At each workstation a double duplex receptacle will be provided. Corridors will have a cleaning receptacle at approximately 25 foot intervals. Exterior weatherproof receptacles will be installed at exterior doors.

L#57297 /Page 3/July 21, 2017 A system of computer grade panelboards with double neutrals and surge protection devices will be provided for receptacle circuits. F. Fire Alarm System: A fire alarm and detection system will be provided with battery back-up. The system will be of the addressable type where each device will be identified at the control panel and remote annunciator by device type and location to facilitate search for origin of alarms. Smoke detectors will be provided in open areas, Auditorium, Corridors, and other egress ways. The sprinkler system will be supervised for water flow and supervisory on valves. Speaker strobes will be provided in egress ways, assembly spaces, open areas, and other large spaces. Strobe only units will be provided in single toilets and conference rooms. Manual pull stations will be provided within 5 feet of all exit doors. The system will be connected to automatically report alarms to the Fire Department. G. Security System: An addressable intrusion security system will be provided. The intrusion system will be integrated with the card access and closed circuit TV (CCTV) system. Position switches will be provided at all exterior doors. A UL Listed closed circuit TV system will be provided. The system will consist of computer servers with image software, computer monitors, and IP based closed circuit TV cameras. The head end server will be located in the server room and will be rack mounted. The system can be accessed from any PC within the facility or externally via an IP address. Each camera can be viewed independently. The Stored Appliance Network (SAN) will store this information for 45 days at 30 images per second. The location of the cameras is generally in corridors, secure areas, and exterior building perimeter. The exterior cameras will pan-tilt-zoom type. The site will be 100% covered. The system will fully integrate with the access control system to allow viewing of events from a single alarm viewer. Camera images and recorded video shall be linked to the access system to allow retrieval of video that is associated with the event.

L#57297 /Page 4/July 21, 2017 The system includes a card access controller, door controllers, and proximity readers/keypads. The electrical hardware for each door will be provided by the door Hardware Contractor. Proximity readers will be located at various locations as shown on the security drawings. The purpose is to only allow access to authorized personnel at all times. Each proximity reader will have a distinctive code to identify the user and a log will be kept in memory. The log within the panel can be accessed through a computer. The alarm condition will also initiate real time recording on the integral CCTV system that is included as part of the system. The system is programmed with graphic maps allowing the end-user to quickly identify alarm conditions and lock/unlock doors. The system will be tested and complete documentation will be provided to the Owner on the operational and programming functions available. The system may be easily expanded to accommodate any additional devices that may be added in the future. H. Lightning Protection System: A system of lightning protection will be provided. The system will be installed in compliance with the provisions of the latest Code for Protection Against Lightning for buildings as adopted by the National Fire Protection Association and the Underwriters Laboratories, for UL Master Label System. The lightning protection equipment will include air terminals, conductors, conduits, fasteners, connectors, ground rods, etc. The lightning protection system will be provided with a UL Master Label Certificate. 3. TESTING REQUIREMENTS The Electrical Contractor shall provide testing of the following systems with the Owner and Owner s Representative present: Lighting and power panels for correct phase balance. Emergency generator system. Lighting control system (interior and exterior). Fire alarm system. Security systems. Testing reports shall be submitted to the Engineer for review and approval before providing to the Owner. 4. OPERATION MANUALS AND MAINTENANCE MANUALS: When the project is completed, the Electrical Contractor shall provide operation and maintenance manuals to the Owner.

L#57297 /Page 5/July 21, 2017 5. RECORD DRAWINGS AND CONTROL DOCUMENTS: When the project is completed, an as-built set of drawings, showing all lighting and power requirements from contract and addendum items will be provided to the Owner. 6. COMMISSIONING: The project will be commissioned per Section 018100 of the Specifications.