EC DECLARATION OF CONFORMITY. The manufacturer or his nominated representative established in the community;

Similar documents
Slip resistance testing of GRP flooring surfaces for Anglia Composites Ltd

Slips and falls. OHS Exchange FDF - Willis. better information, fewer accidents. 22 nd September

Ceram Guide to Slip Resistance Tests

SAFETY ACTION NOTICE By arrangement with the NHSScotland Property and Environment Forum

Slips: framing the issue

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Overhead Line Insulators

Slips, trips and falls. National Metalforming Centre - February Steve Thorpe - HSL

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

MGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE

HazLoc Essential Guides:

Your Key to achieving C.E Marking Compliance

Declaration of Conformity

asphalt applications European Asphalt Standards and their application in the UK mpa asphalt Asphalt Information Service Mineral Products Association

BUSINESS PLAN CEN/TC 160 PROTECTION AGAINST FALLS FROM A HEIGHT INCLUDING WORKING BELTS EXECUTIVE SUMMARY

Review of reports and data for Aero-Therm thermal reflective coating. Prepared for: Mr Craig Clement Director

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

CERTIFICATION OF EXPLOSIVES UNDER G.B. STATUTORY INSTRUMENT No. 2714

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

Guide to Gate Safety Legislation & the Machinery Directive. In Association with:

The Legal Obligations of Employers to Maintain all Electrical Installations in a Safe Condition

ENGINEERING EVALUATION

Guide to Gate Safety Legislation & the Machinery Directive

YOUR GUIDE TO UNDERSTANDING CPR

BCTC CARPET TECHNICAL CENTRE

Refrigerating Appliance ErP Test Report

Standards and third party certification

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Loss Prevention Standard

Loss Prevention Standard

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

BS 476: Part 6: 1989+A1:2009

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

FUNDERMAX GMBH FIRE TEST REPORT

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

BUSINESS PLAN CEN/TC 250 STRUCTURAL EUROCODES EXECUTIVE SUMMARY

FIRE SAFETY POLICY June 2014

SIGMADEK, LTD. FIRE TEST REPORT

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

1. Which national directives/laws control the placing on the market of equipment for explosive atmospheres?

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

Channel Safety Systems Limited Unit 9, Petersfield Business Park Bedford Road Petersfield GU32 3QA UK. Authority & date SMO /04/2014

volume 11 environmental assessment section 2 environmental impact assessment Part 7 ha 218/08

BUSINESS PLAN CEN/TC 162 PROTECTIVE CLOTHING INCLUDING HAND AND ARM PROTECTION AND LIFEJACKETS EXECUTIVE SUMMARY

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

PPE Global Market Access Program

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

ADVISORY COMMITTEE FOR ROOFSAFETY. Information Sheet No.4:2012. BS EN 795 and the 89/686/EEC Directive

Web:

BS EN : 2001 & IEC :2000

Australian/New Zealand Standard

Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

This document is a preview generated by EVS

GASTEC QA. Approval Requirements 136

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Whole Room Dryer WRD, WRD/110

The products covered by the Regulation can be classified as follows:

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

HazLoc Essential Guides:

Type 5 Certifications:

Guide to gate safety legislation and standards

USCG-EU MRA EC TYPE EXAMINATION (MODULE B) CERTIFICATE SAMPLE

BUSINESS PLAN CEN/TC 159 HEARING PROTECTORS EXECUTIVE SUMMARY

5.5 CD/14 (Warning & Advice Notice)

Testing coated fabrics

CE marking & your legal obligations

Guide to Membership Assessments

F O C U S D O O R C L O S E R S

Mandate M/118 WASTE WATER ENGINEERING PRODUCTS

Departure from the Development Plan. Town Council objection to a major application. DETERMINE

European Technical Assessment

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment

Delegated Regulation (EU) 1059/2010 of 28 September 2010 supplementing Directive 2010/30/EU with regard to energy labelling of household dishwashers

Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme:

FLASHLIGHT ANSI STANDARDS

Controlled Door Closing Devices

The new Gas Appliances Regulation (EU) 2016/426

EUROPEAN COMMISSION DIRECTORATE-GENERAL FOR HEALTH AND FOOD SAFETY

BS 476: Part 6: 1989+A1:2009

BS EN ISO : 2010

BS EN ISO : 2010

COMMISSION DELEGATED REGULATION (EU) /... of

Test Report Garvan Enterprises Limited

A Step by Step Guide to Energy Labelling of Gaseous Fuel Local Space Heaters (Part 1)

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

Strebord 35 FD30 Strebord 44 FD30 Strebord 54 FD60

SAIME. KaleidoSeries. 300x300,300x600,600x600&450x900mm Mat(R10CP4),Roc(R12P5)&Lappato. Bianco Beige Avorio. Cappucino Cenere Fango.

INTERNATIONAL STANDARD

COLLECTION OF SAFETY WORKWEAR SHOES

USCG-EU MRA EC TYPE EXAMINATION (MODULE B) CERTIFICATE

Council Directive 93/68/EEC of 22 July 1993 amending Directives

The PPE Directive and the PPE Regulation

CORRECTIONS WITHIN DESIGN MANUAL FOR ROADS AND BRIDGES AUGUST 2009

Transcription:

EC DECLARATION OF CONFORMITY The manufacturer or his nominated representative established in the community; ROCK FALL UK LTD MAJOR HOUSE, UNIT 1 WIMSEY WAY ALFRETON DERBYSHIRE, DE55 4LS UNITED KINGDOM Declares that the PPE described hereafter; TOMCAT RHYOLITE TC3000 Is in conformity with the provisions of Council Directive 89/686/EEC and, where such is the case, with the national standard transposing harmonised standard no. EN ISO 20345:2011 (for the PPE referred to in Article 8(2)) This declaration of conformity is issued under the sole responsibility of the manufacturer; ROCK FALL UK LTD MAJOR HOUSE, UNIT 1 WIMSEY WAY ALFRETON DERBYSHIRE, DE55 4LS UNITED KINGDOM Is identical to the PPE which is subject of EC certificate LECFI00363540 Issued by:- ITS TESTING SERVICES (UK) LTD CENTRE COURT MERIDIAN BUSINESS PARK LEICESTER LE19 1WD Is subject to the procedure set out in Article 11 point A or point B of the Directive 89/686/EEC under the supervision of the notified body: ITS TESTING SERVICES (UK) LTD CENTRE COURT MERIDIAN BUSINESS PARK LEICESTER LE19 1WD Signature: Position: Director Date: 01/01/2017

lntertek EC Type Examination Certificate Issued to : Rock Fall UK Ltd Wimsey Way, Alfreton Trading Estate, Derbyshire, U.K DESS 4LS Manufacturer Approved Body 0362 The safety footwear detailed herein meets the criteria of an EC Type Examination in accordance with Article 1 0 of the PPE Directive (89/686/EEC) including amendments and corrigendum up to 14/12/2010 for intermediate design category products. This has been shown through satisfactory testing to EN ISO 20345: 2011 and examination of the Technical File Documentation. Following an EC Declaration of Product Conformity you are hereby licensed to mark the product(s) detailed in accordance with Article 13 of the PPE Directive (89/686/EEC). Date of Issue : 25 April 2016 Expiry Date : 28 January 2021 Certificate. Product Reference(s) : LEC FI00363540 (Extension to certificate LEC FI00361517) : TOMCAT RHYOLITE TC3000A Description : Construction Cemented Toecap PEP# Composite Midsole PEP# Composite Last #PEP-PL Sole PS-2147# RB Test Report(s) See Technical File Size Range UK 3-13 Category S3 M SRC ITS Testing Services (UK) Ltd. Centre Court Meridian Business Park Leicester, LE19 1WD United Kingdom Phone: +44 (0)116 263 0330 Fax: +44 (0)116 263 0311 *** * * *** www.intertek.com Assessor Certification Manager For and on behalf of ITS Testing Services (UK) Limited 25/04/2016 Date 25/04/2016 Date Registered m England. 1408264 Registered Office: Academy Place, 1-9 Brook Street, Brentwood, Essex. CM14 5NQ This certificate is for the exclusive use of lntertek's Client and 1s provided pursuant to the Certification agreement between lntertek and its Client. lntertek's responsibility and liability are limited to the terms and conditions of the agreement. lntertek assumes no liability to any party, other than to the Client in accordance with the agreement. for any loss. expense or damage occasioned by the use of this Certificate. Only the chant is authorized to permit copying or distribution of this Cert,flcate and then only in,ts entirety. Use of lntertek s Cert1f1cat1on mark is restricted to the conditions laid out in the agreement and in this Cert,ticate. Any further use ot the lntertek name for the sale or advertisement of the tested material, product or service must first be approved m wntmg by lntertek.

lntertek Centre Court Meridian Business Park, Leicester LE19 1WD, United Kingdom Tel: -+44 (0) 116 263 0330 Fax: -+44 (O) 116 263 0311/12 Web: www.intertek.com Test Report Number: LECFIOO 346398 DATE: 04/02/2015 Applicant: Rockfall UK Limited Major House WimseyWay Alferton Trading Estate Derbyshire DESS 4LS For the attention of Richard on Sample Received: 18/12/2014 Your Reference: RKN Specification: British Standards Components: Sample Description: TPU Scuff Cap Material tes: Ref: FORCE 10 Cement Colour: Black Supplier: Rockfall End Use: Safety Boot Scuff Cap Tests Conducted Abrasion Resistance Method Based on EN 388 Sam le Pass/Fail See results RESULTS: See attachment COMMENT: Where the results of a test fall close to the requirement, compliance with the specification may be affected by the uncertainty of measurement of the test. In those circumstances, the client is advised to contact the laboratory for further information Unmarked tests included in this report are on our UKAS Scope 0947. Tests marked (") in this Report are included on lntertek Labtest Leigh UKAS Scope 1516. Tests marked ("") in this Report are included in the UKAS Scope of the sub-contractor who performed the test. Tests marked (*) in this Report are not included in our UKAS Scope. Tests marked (**) in this Report are not included in the UKAS Scope for the sub-contractor who performed the test. Opinions and interpretations expressed herein are outside the scope of UKAS Accreditation. te: A sub-contractor whose certification comes under the ILAC agreement would also be marked in the same manner as a UKAS sub-contractor. BEN PEARCE TEXTILE & PPE TEST CAPABILITY LEA2::0 =, Lab Report: LECFIOO 346398 Page 1 of 3 ITS Testing Services (UK) Limited Registered in England & Wales. Company Number: 1408264. Registered Office: Academy Place, 1-9 Brook Street, Brentwood, Essex CM14 SNQ

lntertek Centre Court Meridian Business Park, Leicester LE19 1WD, United Kingdom Tel: -+44 (0) 116 263 0330 Fax: -+44 (0) 116 263 0311/12 Web: www.intertek.com 0991 *ABRASION RESISTANCE Based on BS EN 388: 2003 Clause 6.1 SAMPLE RESULTS REQUIREMENT Load:9kPa Number of Head 1 Head 2 Revs 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 TPU Footwear scuff cap - Black 24000 26000 28000 30000 32000 34000 36000 Breakdown 38000 -- 40000 -- 42000 -- 44000 -- 46000 -- Comment: Tested Using P180 Grit Paper Head 3 Head 4 req The test was continued for a further 10000 revs. The test was stopped after this point as the samples became too thin to produce good contact with the abradant. Average Score of 43,000 Revs Lab Report: LECFIOO 346398 Page 2 of 3 ITS Testing Services (UK) Limited Registered in England & Wales. Company Number: 1408264. Registered Office: Academy Place, 1-9 Brook Street, Brentwood, Essex CM14 SNQ

lntertek Centre Court Meridian Business Park, Leicester LE19 1WD, United Kingdom Tel: -+44 (0) 116 263 0330 Fax: -+44 (0) 116 263 0311/12 Web: www.intertek.com End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. lntertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing lntertek's provision of services to you. lntertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct Lab Report: LECFIOO 346398 Page 3 of 3 ITS Testing Services (UK) Limited Registered in England & Wales. Company Number: 1408264. Registered Office: Academy Place, 1-9 Brook Street, Brentwood, Essex CM14 SNQ

lntertek Test Report Applicant: Number: Date:,,,,11 1 11,,,, ' '-' '/ :i',, $.. /, I.a ; ye...,,,, :,..,',,1.,,,,, TESTING,,,,,1.,\, CNAS L0220 GZHT90499545 Apr 20, 2015. Sample Description: One (1) piece of submitted sample said to be Cemented lace up low cut shoe in Brown. Standard EN ISO 20347: 2012 Size 42 Sole 2147# RB Date Received/Date Test Started: Feb. 15, 2015 Date Final Information Confirmed: Apr. 20, 2015 Test Result Please Refer To Attached Page(S). Should you have any query on this report, you may contact at qzfootwear@intertek.com Authorized By: For Intertek Testing Services Shenzhen Ltd. Guangzhou Branch 7' Huang Ning, Andy Assistant General Manager wx / tiffanydeng 111111111111111111111111111 IIIII 111111111111111 IIIII IIIII IIIII IIII IIII lntertek Testing Services Shenzhen Limited, Guangzhou Branch Block E,. 7-2, Cai pin Road, Guangzhou Science City, Getdd Guangzhou. 1*:fJll*t1 l1d::s:ti*mhf(cf 0 AJ r-1'1ht0 AJ rffl * ** M 7 =E Tel: +86 20 8213 9001 Fax: +86 20 8208 9909 Postcode: 510663 Page 1 Of 3

lntertek Test Report Tests Conducted (As Requested By The Applicant) Number:,,,.. 1..,,,,, \., 'J,, :::'-._ _,.,,,,..,, 1.a- -. JC,,,,,._,, -:.,,,,;.,, :-,.,, TESTING '1/11111\'' CNAS L0220 GZHT90499545 1 Slip Resistance (EN ISO 20344:2011(5.11) & ISO 13287:2012, SRC, Temperature: 23'C) Requirement Pass/Fail Size 42 Right On Eurotile 2 With NaLS Forward Heel Slip (#1): 0.45 Min. 0.28 Pass Forward Flat Slip (#2): 0.43 Min. 0.32 Pass On Steel Floor With Glycerine Forward Heel Slip (#1): 0.14 Min. 0.13 Pass Forward Flat Slip (#2): 0.19 Min. 0.18 Pass te: It Must Be ted That The Slip Resistance Test carried Out In This Report Denotes An Indication Of Slip Of This Particular Footwear/Component On The Surface Mentioned In The Test Item. It Is Important To te That Footwear Is Subject To Many Different Conditions Encountered In Everyday Use And That It Is Impossible To Make Footwear Resistant To Slip In All Conditions. Nevertheless, It Is Generally Accepted That Problems Are Minimized If The Guideline Coefficients Of Friction Are Achieved. Remark: #1 = Using Standard Shoemaking Last #2 = Using Mechanical Foot Expanded Uncertainty: 0.01, With K = 2.03 At 95% Confidence Level. 2 Abrasion Resistance (Outsole) (EN ISO 20344:2011(8.3), ISO 4649:2010, Method A) Requirement Pass/Fail Size 42 Density 1.2 g/cm 3 Relative Volume Loss 80.5 mm 3 * Pass Remark: * = Density: > 0.9 g/cm 3, Max. 150 mm 3 Expanded Uncertainty: 1.76 mm 3, With k= 1.96 At 95% Confidence Level. This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. wx / tiffanydeng lntertek Testing Services Shenzhen Limited, Guangzhou Branch Block E,. 7-2, Cai pin Road, Guangzhou Science City, Getdd Guangzhou. 1*:!Jll tfjjti:tt# * i0 1,+l:5t0 rffi m *Ha tt 1 2=E Tel: +86 20 8213 9001 Fax: +86 20 8208 9909 Postcode: 510663 Page 2 Of 3

GRIP Rating of Footwear for Rock Fall UK, 2016 Author: Graeme Hunwin Report Number: EPSU/FAL/16/032 HSL: HSE s Health and Safety Laboratory Enabling a Better Working World

GRIP Rating of Footwear for Rock Fall UK, 2016 EXECUTIVE SUMMARY The following soling unit was submitted for rating under the Health and Safety Laboratory (HSL) GRIP Rating Scheme by Rock Fall UK. Soling Unit Identifier Type of Rating FORCE 10 sole Full Page 1 of 8 GRIP Rating Achieved

CONTENTS 1 INTRODUCTION... 3 2 METHODOLOGY... 4 3 RESULTS... 7 4 REFERENCES... 8 Page 2 of 8

1 INTRODUCTION The European Directive 89/686/EEC on Personal Protective Equipment (PPE) recognises the need for slip resistance as a protective property of footwear. Demonstration of compliance with the Directive is usually made through the standards for safety, protective and occupational footwear (BS EN ISO 20345:2011, BS EN ISO 20346:2014 and BS EN ISO 20347:2012). However, these standards only provide a minimum level of compliance with the Directive. The Health & Safety Laboratory (HSL) has developed a rating scheme for the slip resistance of footwear, known as GRIP (HSL, 2014). The GRIP scheme aims to disseminate slip resistance information on footwear, measured according to the HSL Ramp test procedure, through the use of easy to understand ratings. It is intended that the GRIP ratings will allow businesses to identify suitable slip resistant footwear as a control measure to reduce their risk of slipping accidents. This report presents the results of GRIP testing for full rating of the FORCE 10 soling unit, at the request of Rock Fall UK. Testing was co-ordinated by Mr Graeme Hunwin, Falls Prevention Team, Health & Safety Laboratory, during June 2016. Page 3 of 8

2 METHODOLOGY Three sample pairs of Tomcat TC3000A Rhyolite safety boots supplied by Rock Fall UK were tested. The soling unit assessed is listed below in Table 1. Table 1 Soling units supplied for testing HSL ID Soling Unit Identifier FAL/16/024 FORCE 10 sole FAL/16/072 FORCE 10 sole FAL/16/073 FORCE 10 sole Testing was undertaken in accordance with section 6.2 of the GRIP Handbook (HSL, 2014), which is reproduced below: a. Footwear will be tested using the HSL ramp test b. The ramp (Figure 1) consists of an adjustable platform (1), upon which the test flooring material is positioned. A fall arrest device (2) is attached to an overhead frame (3) to prevent injury to the operator during a test. Figure 1 The ramp test c. Test operators will be trained and verification will be undertaken prior to testing. Page 4 of 8

d. The flooring material used for tests shall have the following properties: Floor Type Ceramic tile Pendulum Test Value (UKSRG, 2011) 10 12 Rz Surface Microroughness 5.0 7.0µm e. The test requires the operator to carry out a series of controlled walks over the floor surface. f. Footwear will be prepared by lightly abrading with P400 grit silicon carbide abrasive paper, using an orbital sander, before each operator begins their set of walks. g. The walking method involves the operator taking a series of half steps forward then backward, returning to their start position. h. The walking speed is controlled at 144 steps per minute using a metronome. i. If the operator completes the walk without a slip they increase the angle of inclination of the platform by approximately 1 and repeat the walks. j. The process is repeated until an inclination is reached where a slip occurs; this is defined as the slip angle. k. The slip angle is recorded by an observer, from a display that is hidden from the operator such that knowledge of the slip angle does not influence their walk. l. The platform is returned to an angle of inclination a few degrees below the slip angle and the process is repeated until the operator generates ten slip angles. m. The first two slip angles are discarded, and a mean slip angle is calculated from the remaining eight values, giving the operator result. n. A second operator repeats this process, generating a further 10 slip angles, and a second operator result is calculated. o. The range of the eight slip angles used to calculate the operator result must be no greater than 2.4 for glycerol tests and 3.6 for water tests, otherwise a third operator will generate a third operator result. p. The difference between two operator results must be no greater than 1.8 for glycerol and 2.5 for water, otherwise a third operator will generate a third operator result. q. Where the third operator result fails to meet the acceptance criteria set out in (o) or (p) a fourth operator will generate a fourth operator result. r. The test result is the mean of all the operator results obtained. s. The test result will be converted into the coefficient of friction by taking the tangent of the test result. The test result obtained for footwear supplied for re-rating must fall within the expected range of the three pairs previously tested. The footwear is rated in accordance with the requirements in Table 2. Page 5 of 8

Table 2 The test conditions and GRIP rating requirements Test Condition 1 Test Condition 2 GRIP Rating Measured CoF Test Condition 1 Test Condition 2 Water - 0.19-1 Star Water - 0.27-2 Star Water - 0.36-3 Star Water Glycerol (75% solution) 0.36 0.19 4 Star Water Glycerol (75% solution) 0.36 0.27 5 Star Page 6 of 8

3 RESULTS The test results for the footwear supplied for GRIP rating are presented below. Footwear: Tomcat TC3000A Rhyolite safety boot Soling Unit identifier: FORCE 10 sole Figure 2 The FORCE 10 soling unit Contaminant: Water Sample ID Operator 1 ( ) Operator 2 ( ) Test Result ( ) CoF FAL/16/024 FAL/16/072 FAL/16/073 15.6 14.7 17.7 15.6 13.8 17.9 15.6 14.3 17.8 0.28 0.25 0.32 Mean 15.9 0.28 Contaminant: 75% Glycerol solution Sample ID Operator 1 ( ) Operator 2 ( ) Test Result ( ) CoF FAL/16/024 FAL/16/072 FAL/16/073 4.1 5.2 6.7 3.4 4.0 4.9 3.7 4.6 5.8 0.07 0.08 0.10 Mean 4.7 0.08 Rating: Page 7 of 8

4 REFERENCES British Standards Institution, (2011), BS EN ISO 20345: 2011, Personal protective equipment. Safety footwear, British Standards Institution, London. British Standards Institution, (2014), BS EN ISO 20346: 2014, Personal protective equipment. Protective footwear, British Standards Institution, London. British Standards Institution, (2012), BS EN ISO 20347: 2012, Personal protective equipment. Occupational footwear, British Standards Institution, London. Council Directive 89/686/EEC of 21st December 1989 on the approximation of the laws of the Member States relating to personal protective equipment, 1989, OJ. L 399/18. Health and Safety Laboratory, (2014), The GRIP Scheme, Footwear Slip Resistance Ratings, Handbook for Participants, http://www.hsl.gov.uk/media/435727/the%20grip%20scheme%20handbook%20v1.1.pdf. Health and Safety Laboratory, last accessed: 10/3/2016. UKSRG, (2011), The Assessment of Floor Surface Slipperiness: The UK Slip Resistance Group Guidelines Issue 4, 2011, The United Kingdom Slip Resistance Group (UKSRG). Page 8 of 8

HSL: HSE s Health and Safety Laboratory is one of the world's leading providers of health and safety solutions to industry, government and professional bodies. The main focus of our work is on understanding and reducing health and safety risks. We provide health and safety expert advice and consultancy, research, specialist training and products. At HSL, we have been developing health and safety solutions for over 100 years. Our long history means that we're well placed to understand the changing health and safety landscape, and anticipate future issues. We employ over 450 scientific, medical and technical specialists, including occupational health and risk management experts to help our clients manage a wide range of issues in workplace health and safety. ISO 9001 ISO 14001 OHSAS 18001 Health and Safety Laboratory Harpur Hill Buxton Derbyshire SK17 9JN UK www.hsl.gov.uk T : +44 (0) 1298 218000 E: hslinfo@hsl.gsi.gov.uk Page 9 of 8