LOSBAY800. BAY SENSOR Installation Manual. LOSBAY800 Specifications

Similar documents
LOS SUPER CEILING SENSOR Installation Manual

SLIM 37 INSTALLATION INSTRUCTIONS

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Versatility. Maximum Energy Savings

WPLED 26W INSTALLATION INSTRUCTIONS

GOTCHA! PLUS INSTALLATION INSTRUCTIONS

Installation Instructions

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

STLDIM10 INSTALLATION INSTRUCTIONS

MaxLite LED Vapor Tight Linear Fixture

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

GLED INSTALLATION INSTRUCTIONS

Motion Sensor. Specifications

IMPORTANT SAFETY INFORMATION:

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

Talking Wireless Detection System. Installation Manual. Tells you where & when someone s been detected RAB

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

MaxLite LED MICRO-T PANEL

Installation Instructions

MaxLite LED High Bay Fixtures

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

Installation Instructions

Retro Flip Alarm Clock MODEL: CH1200/1/2

PMCSF6 OCCUPANCY SENSOR

e Bath Fan with Light User s Guide

Installation Instructions

ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

BALLAST SOURCE EB- Electronic ballast BALLAST QUANTITY. 1-(1) 4-light ballast LAMP SPECIFICATIONS SPECIFICATIONS

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

e Bath Fan with Light User s Guide

BOLLARD EMERGENCY INSTALLATION INSTRUCTIONS

LPCMPIRM65 & LPCMPIRDSI65

GLED INSTALLATION INSTRUCTIONS

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

52 BARSTOW CEILING FAN

52 BAYTOWNE CEILING FAN

Installation Instructions

SYSTEM CONTROL KIT Model: CK-41P

3M Overhead Ionizing Blower 991A

ST. KITTS CEILING FAN

SERVICE BY QUALIFIED PERSONNEL ONLY

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Inside. Wall Gasket. Fixture Wall. Certifications. Year Warranty. -40 C C Operating

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

MaxLite LED Round Pendant Highbay Series

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

Installation Manual. Models 99168, 99169, 99170

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

DHL-LP-LED Low Profile LED Linear High/Low Bay

52 SAN LUCAS CEILING FAN

52 STRATHMERE CEILING FAN

52 BERKSHIRE CEILING FAN

LIMITED LIFETIME WARRANTY

e Heater/Exhaust Fan/Light User s Guide

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

Decorative Low Profile Integrated Kit

Installation & Operation Manual for WarmlyYours Riviera Towel Warmers

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

User s Manual and Operating Instructions

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

30W LED PIR FLOODLIGHT. Model: LEDX30PIRB Model: LEDX30PIRWH

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

Compact Movement Activated Sensor Installation Instructions

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

Here is what comes in your box:

18 INCHES, OSCILLATING STAND FAN

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

DHL-LP-LED Low Profile LED Linear High/Low Bay

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

Mini Product Guide.

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

THE VALOR CEILING FAN INSTALLATION INSTRUCTIONS

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

INSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES AND WD-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

Infrared Wall Mount Occupancy Sensor

ELSTON 52 CEILING FAN

Innovative Lighting R-Series Vertical Refrigeration

A2Z Ozone, Inc. PRODUCT MANUAL

120 VAC SYSTEM CONTROL KIT Model: CK-63

Hardwired Electric Garage Heater

Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller

THE CHATEAUX 52"/60" UNI PACK CEILING FAN INSTALLATION INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS

Transcription:

LOSBAY800 BAY SENSOR Installation Manual LOSBAY800 Specifications Coverage Area: 50-60 diameter @ 40 height Time Delay: 30 seconds to 30 minutes Photocell Adjustment: 3.7 fc to185 fc (40-2000 Lux) Operating Temperature: -10 C to 70 C (14 F to 160 F) Relative Humidity: 20-85% Power Consumption: 2W@120V, 1W@277V, 0.8W @347V Switching Capacity: 120VAC: 800VA - 6.67A, 50/60 Hz 277VAC: 1200VA - 4.33A, 50/60 Hz 347VAC: 1500VA - 4.32A, 50/60 Hz

CAUTION: For your own safety and to prevent damage to the unit, turn off ALL power by removing the power fuse or turning off the circuit breaker. Please read the entire Installation Manual before proceeding. All wiring should comply with local electrical codes and requires a qualified electrician. Use this device with copper or copper clad wire only. With aluminium wire use devices marked CO/ALR or CU/AL only. Be sure the total lighting load connected to the LOSBAY800 does not exceed the following ratings: 120VAC: 800VA - 6.67A, 50/60 Hz 277VAC: 1200VA - 4.33A, 50/60 Hz 347VAC: 1500VA - 4.32A, 50/60 Hz Instant Start fluorescent ballasts may not be rated for use with any kind of occupancy sensor. The LOSBAY800 cannot be used with dimmers. Operating Temperature: -10 C to 70 C (14 F to 160 F) Relative Humidity:20-85% Warmup: After the power is turned ON, allow 2 minutes for warm up. The controlled lights will be on for the entire 2 minutes. After warm up is complete the unit will operate according to set time delay and lux settings. LED: The sensor has an internal green LED, visible through the lens, which activates when motion is detected. Time: This Time knob controls the amount of time lights stay ON after the last detected motion. Settings varying from 30 seconds to 30 minutes. Photocell: The Lux knob controls the light level at which the sensor will switch on the lights when movement is detected. If set to the maximum ( sun ) it will switch during most lighting conditions. If set to minimum ( moon ) the sensor will only operate at dusk or light conditions darker than dusk. This is the ideal position for general early evening and night operation. 25 LUX Lux 30MIN. 30SEC. 15 TIME Time 5 How Do RAB Occupancy Sensors Work? The L0SBAY800 sensor sees infrared heat changes caused by movement within the detection zone and turns on lights automatically. How long do the lights stay on? Lights stay on as long as motion is detected. The controlled lights ( on the same circuit) will remain ON until no more motion is detected and the pre-set time-delay has expired. You can adjust the delay from 30 seconds to 30 minutes. How much motion is necessary to keep lights on? In order to activate the sensor, the source of heat must move from one zone of detection to another. It is recommended to mount the sensor at least 6 away from heating, cooling and ventilation perpendicular to the direction of movement. How large an area does the LOSBAY800 cover? The Bay Lens and Aisle Lens are designed for 20 to 40 mounting heights with a symmetrical coverage pattern of 50 to 60 in diameter. 40 360 top View Aisle top View Power Consumption: 2W@120V, 1W@277V, 0.8W @347V 40 20 20 LOSBAY800-IN-1012 2 3

Selecting A Location Lens Installation Locate the LOSBAY800 where it has an unobstructed view of the area, particularly the areas normally occupied by people. 1. The sensor is supplied with two lenses, a factory installed 360 Bay Lens and an optional un-installed Aisle Lens (black color trim ring). Dots If people can not see the sensor lens from their normal positions in the area, the sensor will not detect their presence. High shelving, pallet racks, walls, columns, doors and other obstructions may limit the sensors view. If obstructions can be moved, the sensor will have a better view. If the obstructed areas are not normally occupied, the sensor will still see sufficient activity to operate properly. Several sensors may be needed to cover large or oddly shaped areas. incorrect Sensor mounted too high Outer beams are obstructed Field-of-view is limited 2. To change lens, turn the trim ring so that the two indented dots line up and pull out by the finger tabs. 3. To insert the black aisle lens, line up the indented dots and the tabs on underside of lens and insert into key openings and turn clockwise. 4. Turn the lens clockwise further to orient the aisle direction from 0 to 90. Location of dots for respective positions is illustrated below. Line up the dots and pull up tab to remove 360 lens Warehouses can have ambient temperature variations that may affect sensor detection and coverage location. High temperatures at the covered area (above 89-92 F) reduce the detection zone of the sensor. Consider adding more sensors if ambient temperatures are expected to be high. High floor level temperature may require larger movement for detection. In some cases, sensors mounted above 40 may only detect large heat signatures such as forklift trucks. correct Sensor mounted 1 off bottom No obstruction Optimum field-of-view 0 Aisle Dots Insert aisle lens with dots lined up When Heating, Ventilating or Air Conditioning (HVAC) registers turn on they create turbulence which can cause the sensor to activate. It is important that the sensor and HVAC register be separated by at least 6. 90 Aisle Turn clockwise to change aisle direction Dots LOSBAY800-IN-1012 4 5

Mounting Wiring Troubleshooting BAYLED Mounting 1. The LOSBAY800 sensor threads into a 1/2 NPS hole on the end of a housing or junction box. To mount to BAYLED use stem as shown. LOSBAYMK can be ordered separately if needed. 2. Thread locknuts onto to each side of 6 minimum 1/2 NPS Stem. 3. Place adaptor on stem and use third lock nut to secure the back piece of the Adaptor to the stem. 4. Mount sensor to front piece of the Adaptor in the Non-Keyed Hole and tighten it with lock nut. 5. Feed the wires from the sensor through the Stem and into the fixture. 6. Snap front and back Adaptor pieces together. 7. Mount Stem to housing and tighten all locknuts. 8. Connect wires according to wiring diagram. Adaptor Stem R-Bay Mounting 1. The included adaptor may be used as shown, to expand the sensor s field of view if it is obstructed by the RBAY. As long as sensor is mounted within 1 from the bottom of the fixture, the field of view will not be affected. 2. Threaded snap-in nipple attaches to 1/2 luminaire or electrical box trade size Knockout Holes. 3. Adaptor has alternate Keyholes for height adjustment. 4. Sensor mounts at the Non-Keyed Hole. 5. Wires from sensor to luminaire or electrical box are fed through Adaptor. Adaptor Bracket allows sensor to be mounted to achieve optimum field-of view Knockout Holes Wiring Diagram Live(Black) Line 120-347VAC 50-60Hz Neutral(White) Black White Red Black Load White Lights do Not Turn On 1. Circuit breaker or fuse is OFF: Turn the breaker ON. Ensure lights being controlled are in working order. 2. Sensor is wired incorrectly or may be defective: Confirm that the sensor wiring is correct. 3. Lens is dirty or obstructed: Inspect the lens visually and clean, if necessary, or remove the obstruction. Lights Do Not Turn Off 1. Sensor is wired incorrectly or may be defective: Confirm that the sensor wiring is correct and inspect visually for problems. 2. Sensor may be mounted too closely to an air conditioning or heating vent: Move the sensor or close the vent. 3. The line voltage has dropped: Perform the necessary tests to ensure the line voltage does not drop below 100V. Lights Turn OFF and ON too quickly: 1. Sensor may be mounted too closely to an air conditioning or heating vent: Move the sensor or close the vent. Keyholes 2. Time set improperly: Adjust the TIME control knob. Non-Keyed Hole (for sensor mounting) Adaptor LOSBAY800-IN-1012 6 7

Limited Warranty Your LOSBAY800 will be replaced or repaired at our option if it proves to be defective in workmanship or materials within five year from the date of original purchase. For repair or replacement return the product (freight prepaid and insured) to the address on back after packing it carefully. Please include your sales receipt and a description of the problem. If your unit is out of warranty or the damage is unrelated to the original manufacture, return your unit directly to us with a check for $20 (made payable to RAB Lighting Inc.) for repair or replacement of the unit. Maintenance & Repair LOSBAY800 requires no maintenance other than keeping the lens area clean and free of obstructions. Clean outer surface with a damp cloth only. Do not attempt to open or repair the sensor. There are dangerous voltages inside the case, and no user serviceable parts. Opening the sensor voids the warranty. For repair service, follow your warranty instructions. Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance. Under no circumstances is RAB Lighting liable for any incidental or consequential damage arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property or revenue or cost of installation, removal or re-installation. This warranty gives you specific legal rights which vary from state to state. Easy Installation & Product Help 2012 RAB LIGHTING Inc. Northvale, New Jersey 07647 USA Tech Help Line Call our experts 888 RAB-1000 rabweb.com Visit our website for product info email Answered promptly sales@rabweb.com

GDBAYLEDW WIRE GUARD Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We d like to hear your comments. Call the Marketing Department at 888-RAB-1000, or email: marketing@rabweb.com IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. WARNING: Make certain power is OFF before installing or maintaining fixture. Installation Wire Guard mounts with four stainless steel Screws to door as shown. Hardware is provided with guard. Guard and shield may be used together. Wire Guard Screws (4) CLEANING Clean glass lens with nonabrasive glass cleaning solution. CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized. Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance. Easy Installation & Product Help 2012 RAB LIGHTING Inc. Northvale, New Jersey 07647 USA Tech Help Line Call our experts 888 RAB-1000 rabweb.com Visit our website for product info email Answered promptly sales@rabweb.com GDBAYLEDW IN 1112

GDBAYLEDP POLY SHIELD Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We d like to hear your comments. Call the Marketing Department at 888-RAB-1000, or email: marketing@rabweb.com IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. WARNING: Make certain power is OFF before installing or maintaining fixture. Installation Polyshield mounts with four stainless steel Screws to door as shown. Hardware is provided with guard. Guard and shield may be used together. Polyshield Screws (4) CLEANING Clean glass lens with nonabrasive glass cleaning solution. CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized. Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance. Easy Installation & Product Help 2012 RAB LIGHTING Inc. Northvale, New Jersey 07647 USA Tech Help Line Call our experts 888 RAB-1000 rabweb.com Visit our website for product info email Answered promptly sales@rabweb.com GDBAYLEDP IN 1112

GDBAYLED78FP FROSTED POLY SHIELD Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We d like to hear your comments. Call the Marketing Department at 888-RAB-1000, or email: marketing@rabweb.com IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. WARNING: Make certain power is OFF before installing or maintaining fixture. INSTALLATION Frosted Polyshield mounts with (4) Spacers and (4) stainless steel Screws to door as shown. Hardware is provided with shield. Spacers (4) Frosted Polyshield Screws (4) CLEANING Clean glass lens with nonabrasive cleaning solution. CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized. Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance. Easy Installation & Product Help Tech Help Line 2014 RAB LIGHTING Inc. Northvale, New Jersey 07647 USA Call our experts 888 RAB-1000 GDBAYLEDFP IN 0814 rabweb.com Visit our website for product info email Answered promptly sales@rabweb.com