Air conditioning. VRF systems

Similar documents
Air Conditioning. Air Conditioning. VRF systems

Air Conditioning. Air conditioning. Overview

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Air Conditioning. Air Conditioning. Light Commercial, Commercial and Industrial. March 2018

HHCompact. Standard units even better

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

DAIKIN Air Handling Unit Modular

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

2017 LINE UP MINI SPLITS CATALOG

Product Line Introduction. Karl Zhang Technical support engineer

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

LG VRF Systems. Air Conditioning Technologies

DC Inverter Smart VRF Products(R410A)

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. ERV-RT Series. Rooftop Units.

Ultimate VRF System R410A, 50Hz

Flexline NG. Air Handling Unit

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

VRF 50Hz. Commercial Air Conditioners V1510. V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF. Commercial Air Conditioner Division Midea Group

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Healthcare

Modular Air Cooled Scroll Chillers

Variable Refrigerant Flow

Green Ventilation Jet Fan Systems for Car Parks

Midea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15

Systemair product news - Fans NEWS

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Business. The business range. The most advanced solutions for larger buildings.

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

recooler HP EQKR HEAT PUMP

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Office

Air Cooled Scroll Chiller

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Lennox Mini-Split Systems Year-Round Comfort and Performance

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

VARIABLE REFRIGERANT FLOW SYSTEMS

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

Conditioning your ambient, maximising your comfort.

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

LG HVAC SOLUTION. LG Electronics Distributed by. Copyright 2016 LG Electronics. All rights reserved.

Product overview. Marine Applications

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

A more comfortable, safe and sustainable world

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL

SMC DUCTED. High Performance AIR CONDITIONING SYSTEMS

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

ClimaMaster Series. Rooftop Package Unit 50Hz 1311-R1211. D e a l e r i n f o r m a t i o n

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

DC inverter VRF presentation

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

DVU-HP. Integrated Reversible Heat Pump System

All DC Inverter Multi VRF

2017 LINE UP MINI SPLITS CATALOG

PRODUCT GUIDE

SIMPLICITY FULL MODULARITY?

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Water systems. Providing indoor climate comfort

Heat Pump Air Conditioning Systems

Integrated VarIable refrigerant flow ahu/pau (r410a)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

Inventor of the Inverter Digital Inverter System

3 rd Generation of VRV. The professional solution for your professional project

Blending Commercial and Residential. MiNi VRF

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

MRVIII-S. 007 Features & Benefits 017 MRVIII-S Outdoor

AHU Plus. DX Air Handling Units

SysAer. An efficient rooftop unit. Chillers & Heat Pumps Water terminals Rooftops Close control Water source heat pumps Direct expansion.

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

Inverter Wall Mounted Series

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

VANJSKE JEDINICE. Variable Refrigerant Flow Systems. *Preliminary data

PANASONIC INDUSTRIAL VRF SYSTEMS

Product Brochure Smart Power. Low Profile Ducted

Trust Systemair. Product overview. One partner a million possibilities.

Air to water Heat Pump System

AQUASNAP JUNIOR 30RHV

VRV IV heat recovery Best efficiency and comfort solution

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

Do you want a versatile solution

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

PROCESS AND CLIMATE COOLING

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

Transcription:

Fans Air Handling Units Air Distribution Products Air Conditioning Fire Safety Air Curtains and Heating Products Tunnel Fans Air conditioning VRF systems

Systemair Trust We consider your trust in us as a supplier an important goal. It is always included in our work on all levels and in all areas whether it is a question of cooperation, quality, deliveries or documentation. This catalogue is of course a part of this work. With this catalogue, which features products of air conditioning, we want to give you as a customer a general overview of what Systemair can offer within this field. More detailed information is available in our Online catalogue at www.systemair.com and as downloadable software. Systemair s range of fans, air distribution products and accessories also appears in our printed main catalogue. Our product development leads the field - latest technologies in unitdesign, fans, motors, heat recovery, chillers, fan coils,... interact to give high efficiency and with that low power consumption. Systemair has grown each year since the start and we aim to continue with this trend. Systemair strives to be a reliable supplier of quality products. We help our customers to focus on their own business. Reliable deliveres give the customers greater possibilities to quickly complete a job, and move on to the next project. At Systemair we call this Trust. Systemair 2017. Systemair reserves the right to make technical changes. For updated documentation, please refer to www.systemair.com

Content 3 Content Systemair 4 Product Range 6 Application 8 VRF systems 10 Mini VRF SYSVRF AIR EVO HP 14 VRF Heat Pump SYSVRF AIR EVO HP 16 VRF Heat Recovery SYSVRF AIR EVO HR 20 VRF Heat Recovery switch module SYSVRF BOX HR 22 VRF Heat Recovery combination 24 VRF Heat Pump water-cooled SYSVRF WATER EVO HP 26 VRF water-cooled combination 28 VRF Wall Indoor units SYSVRF WALL 30 VRF Compact Cassette indoor units SYSVRF MINI 32 VRF Cassette indoor units SYSVRF 34 VRF Cassette 1way indoor units SYSVRF 1W 36 VRF Cassette 2way indoor units SYSVRF 2W 38 VRF Ceiling/Floor indoor units SYSVRF CEILING 40 VRF Duct indoor units SYSVRF DUCT 42 VRF Duct HP indoor units SYSVRF DUCT HP 44 Exposed floor indoor unit SYSVRF FLOOR EB 46 Concealed floor indoor unit SYSVRF FLOOR CB 48 VRF Heat Recovery Ventilation SYSVRF HRV 50 VRF connection to AHU SYSVRF AHU 52 VRF control systems 54

4 Systemair Manufacturing around the world Skinnskatteberg, Sweden The Group headquarters, distribution center and largest production site. Production of compact air handling units, a wide range of fans and accessories, air curtains and fan heaters. Hässleholm, Sweden Production of heating products for air handling units, fan heaters and dehumidifiers. Windischbuch, Germany Production facility and distribution center, specializing in engineered products. Langenfeld, Germany Production of air curtains. Mühlheim an der Ruhr, Germany Production of air handling units for swimming pool halls and comfort ventilation. Ukmergé, Lithuania Production of residential units and large air handling units. Maribor, Slovenia Production of high-temperature fans for smoke extract ventilation. Aarhus, Denmark Production of large air handling units. Bratislava, Slovakia Production of air distribution products and fire dampers. Hyderabad, India Production of air distribution products. Greater Noida, New Delhi, India Production of duct, axial and box fans, air handling units and air distribution products. Kuala Lumpur, Malaysia Production of duct and axial fans. Johannesburg, South Africa Production of axial fans. Lenexa, USA Manufacturing and distribution center of ventilation products.

Systemair 5 Our commitment to quality Systemair is certified in accordance with ISO 9001, ISO 14001, ATEX and European fire safety standard EN 12101-3. Our research and development laboratories are among the most modern in Europe. Our measurements are made in accordance with international standards such as AMCA and ISO. Save energy and lower running costs! Our Green Ventilation label highlights products that combine energy economy with energy efficiency, offering end users high energy-saving potential. The ErP symbol indicates that the product fulfills EU demands on energy consumption. Kansas City, USA Bouctouche, Canada Tillsonburg, Canada Eidsvoll, Norway Skinnskatteberg, Sweden Hässleholm, Sweden Aarhus, Denmark Ukmergé, Lithuania Windischbuch, Helmstadt, Langenfeld, Waalwijk, The Netherlands Mühlheim a.d.r., Winterbach, Germany Pardubice, Czech Bratislava, Slovakia Tillières, France Maribor, Slovenia Milan, Italy Istanbul, Turkey Madrid, Spain New Delhi, India Wujiang, China Hyderabad, India Kuala Lumpur, Malaysia São Paulo, Brazil Johannesburg, South Africa Milan, Italy Production of liquid and air-cooled chillers and heat pumps for comfort cooling. Tilliéres, France Production of air conditioning products for the commercial market. Madrid, Spain Production of large air handling units and box fans. Bouctouche, Canada Production of air handling units. Tillsonburg, Canada Production of air handling units. Eidsvoll, Norway Production of air handling units. Istanbul, Turkey Production of air handling units and fan coils. Waalwijk, The Netherlands Production of air handling units. Pardubice, Czech Rep. Development and manufacturing of air handling units and air curtains Winterbach, Germany Development and production of high end air air curtains. Helmstadt, Germany Manufacturing of rotary heat exchangers. Sau Paolo, Brasil Manufacturing of air handling units and accessories. Wujiang, China Production of air handling units

6 Product range Product range Systemair has an extensive range of ventilation products: fans including smoke extract, tunnel and car park fans, explosion proof fans, air handling units from large central units to small residential units with energy recovery, air distribution products and fire dampers. These products are installed in a variety of locations, including homes, offices, healthcare premises, shops, industrial buildings, tunnels, parking garages, training facilities, sports centres etc. Fans Systemair has the wider range of fans for use in different applications. Our range includes any type of fans, from circular ducts hystorical product boxed up to those of extraction, axial, and explosion-proof for the extraction of fumes. All products listed above are made in different dimensions from 100 mm in diameter to fans of large size for tunnel. All our fans are designed to meet the strict requirements, easy to use, high quality and durability. Duct fans Duct fans for circular duct installation. Centrifugal fans Centrifugal supply single fans. Rectangular duct fans Duct fans with rectangular connection. Square duct fans For different applications, there are models for ambient with high temperature. Axial fans Axial fans for duct or wall application. Roof fans Roof fans with circular or square connection. Explosion proof fans Explosion proof fans in duct, roof or wall design. Jet Axial Fans Jet Axial Fans for car park, tunnels and air overpression. High temperature fans Systemair provides high fire resistance fans till 600 C/2 hours.

Product range 7 Air handling units Systemair produces a wide range of air handling units for several applications, from small office to large industrial building. All range is been developped to satisfy strict needs of low energy consumption. Fire and smoke dampers Smoke extract fans High efficient fans to extract the combustion smoke. Fire & smoke dampers Dampers that reduce the spread of smoke and fire. Residential ventilation Complete energy-efficient air handling units with heat recovery and built in control systems. Designed to be mounted over the cooker, on walls or horizontally in attics. Residential units For homes with living areas of 60-320 m 2. Cooker hoods Ideal for capturing odours even at low airflows. Air distribution products The range also includes a wide selection of air distribution products and accessories. Supply, extract & transfer devices For mounting in ceilings or walls. Nozzle diffusers Optimum flexibility and comfort in air distribution for rooms. Air Conditioning The strengh point of Systemair Air Conditioning products is a wide range with several options and accessories: chiller, water terminal, close control, roof top, water source heat pump etc.

Applications Schools In buildings for school, the load to be disposed is variable during the day due to the presence of people only for some periods, thus it is mandatory to control the users requirements during daily plant use. Systemair offers a wide range of equipment suitable for this purpose, the fan coils with EC motors allow to obtain the required flexibility. Offices In buildings for tertiary application, the air conditioning and the ventilation are necessary during the day. The heat loads to be removed are generally generated by people present, from the lighting system, from solar radiation and by machines. Normally it is necessary the use of chillers, Heat Pump to produce cold and/or hot water to be sent to hydronic (fan coils, cassettes, ducted) to obtain an optimum air conditioning of offices.

Commercial buildings Normally the number of people varies continuously; the optimal solution would be to use machinery for the conditioning with variable flow and with constant monitoring of concentration of pollutants (VOC and CO2). Systemair products can easily meet the plantʼs requirement. Industry Industrial plants generate a large amount of heat that must be dissipated in the appropriate way. Systemair offers a wide range of products (chillers from 20 kw to 1.680 kw) that can be readily integrated industrial installation. The chiller can be used both for air conditioning and for the cooling equipment process (production of chilled water up to -10 C). Hotels In the hotel rooms, it is needed a high level of comfort with the minimum impact with respect to the noise level. Systemair ducted products equipped with EC motors fully comply with requirements efficiency, cooling capacity and sound impact, required by this type of installations.

10 VRF systems SYSVRF

VRF systems 11 SYSVRF multi-zone solutions: light commercial and commercial VRF systems The SYSVRF modular systems are most valuable for room space from 100 to 1000 sq.m. with large independence of climatic zones - hotels, restaurants, retail, office buildings, etc. Up to 4 modular outdoor units can be combined in one single refrigerant system thus reaching up to 246kW of cooling capacity and connecting up to indoor units. In the same system they are able to fulfill the increasing demands of air comfort still having low operating costs. All SYSVRF systems are equipped with DC Inverter compressors and DC Inverter fans which gives enhanced system performance and very low operating noise. The new generation of 3-pipe systems are equipped with all DC Inverter compressor which delivers outstanding comfort pleasure and reduces tremendously the electricity consumption. SYSVRF of Systemair are available with different configurations: the typical heat pump Mini and Modular 2-pipe outdoor units Air-cooled or Water-cooled and the superior Modular heat recovery 3-pipe units. SYSVRF Mini and SYSVRF Modular systems SYSVRF AIR EVO HP Mini 14 SYSVRF DUCT 42 SYSVRF AIR EVO HP 16 SYSVRF DUCT HP 44 SYSVRF AIR EVO HR 20 SYSVRF FLOOR EB 46 SYSVRF WATER EVO HP 26 SYSVRF FLOOR CB 48 SYSVRF WALL 30 SYSVRF HRV 50 SYSVRF MINI 32 SYSVRF AHU 52 SYSVRF 34 SYSVRF selection software 53 SYSVRF 1 WAY 36 SYSVRFsystems 54 SYSVRF 2 WAY 38 accessories 60 SYSVRF CEILING 40

12 VRF systems VRF Systemair- SYSVRF Multi-zone air conditioning system VRF systems are most beneficial for space up to 15002000 sq.m. with large independence of climatic zones hotels, restaurants, retail space, office buildings, etc. In the same system they are able to fulfill the increasing demands of the parameters of air in each room and still have low operating costs. The most comfortable temperature An important advantage of the multi-zone air-conditioning is a smooth and rapid achievement of a comfortable temperature, as well as maintaining the specified parameters accurate to ± 0,5 C. Such high performance was achieved thanks to an accurate control of the refrigerant flow and the mechanism of redistribution of refrigerant between the several units, implemented with the help of electronic expansion valves. High energy efficiency The efficiency of multi-zone systems is very high, because each time the electric power is consumed as much as necessary to carry out user requirements. If the indoor units work only in a few areas of the building, then the power consumption is reduced proportionally by changing the refrigerant flow. Low noise Low noise of both outdoor and indoor units makes the job a multizone system virtually inconspicuous. A balanced lineup The lineup of multizone VRF series are continuously optimized. In response to market demands Systemair offers several types and sizes of indoor units: wallmounted, cassette, floor-ceiling and duct. Outdoor units Mini, despite the compact dimensions, solve different tasks of air conditioning on small objects. Four modular outdoor units can be combined in one refrigerant system thus reaching a total cooling capacity of up to 246 kw. Separately, to highlight the 3 Pipe heat recovery system for indipendent and simultaneous cooling and heating operation. Continuous development in the field of management In modern air-conditioning systems the demand for automation and control systems integrated with other infrastructure building systems is continuously increasing. These are exactly the principles on the basic of the development of the control systems of Systemair. In addition to the traditional control systems of air conditioning, the user deals with different possibilities of control that can solve the various needs of the building management such as the possibility of control via personal computer and Internet network connection. Simplicity of design Systemair provides full integration and coordination of all elements of a multizone system, greatly simplifies the task of the designer. The selection process can be performed in maximum short period of time by using a simple and complete selection and designing software.

VRF systems 13 SYSVRF lineup In 2014 Systemair launched a new generation of VRF multi-zone systems - the SYSVRF series. The basis principle of work lies on the advantages of the DC Inverter technology and scroll compressors and the achieved results far exceed the high standards set by the industry. Through the use of modern technologies and implementation of their own development has significantly improved energy efficiency and decreased the noise level, with compact dimensions, increased ease of installation and maintenance, greatly expanded the range of application from light commercial to large commercial spaces. SYSVRF outdoor units SYSVRF mini 2 Pipe Heat Pump SYSVRF AIR EVO HR Modular 3 Pipe Heat Recovery SYSVRF AIR EVO HP Modular 2 Pipe Heat Pump SYSVRF WATER EVO HP Modular 2 Pipe Heat Pump 8,0-22,4 kw 25,0-180,0 kw 25,0-246,0 kw 25,0-100,0 kw SYSVRF WALL SYSVRF CEILING SYSVRF MINI 2,2-8,0 kw 3,6-14,0 kw 1,5-5,6 kw SYSVRF Indoor units SYSVRF 2,8-14,0 kw SYSVRF 1 WAY 1,8-7,1 kw SYSVRF 2 WAY 2,2-5,6 kw SYSVRF DUCT SYSVRF DUCT HP SYSVRF HRV 1,5-14,0 kw 7,1-28,0 kw 500-2.000 m 3 /h SYSVRF FLOOR EB SYSVRF FLOOR CB SYSVRF AHU 2,2-8,0 kw 2,2-8,0 kw 9,0-56 kw Compatible outdoor and indoor series Outdoor units of the SYSVRF Mini, Heat Pump and Heat Recovery series are compatible with all types of SYSVRF indoor units. There are 10 different types of indoor units available with capacity from 1,5 kw to 28,0 kw, making the total number of indoor units equal to 69 different types and capacities. The ventilation function can be provided through the SYSVRF HRV units or through the combination of a Systemair air handling unit with the control module SYSVRF AHU.

14 Mini VRF Mini VRF Heat Pump Outdoor Units SYSVRF AIR EVO HP Features Full DC Inverter Mini VRF with DC Inverter compressor and DC fan motor. Compact size and long piping system. High efficiency at partial load. Inverter Rotary compressor providing wide capacity output from 10% to 100% evenly. Centralized control, BMS connection and web access potential. Hydrophilic Blue Fin coil enhances durability and protection against corrosion. Piping connection in four different directions makes simple the installation of outdoor unit. Maximum 11 indoor units connection. Indoor unit combination total capacity index from 45% to 130%. With the branch SYSVRF BRANCH 04 MINI (Art. no. 314803) the installation is easy and safe, all connections from outdoor unit and indoor units are flanged, which greatly simplifies field installations. Dimensions SYSVRF 120 to 180 and 224 SYSVRF 080 H 1075 A Model 080 120 to 180 224 A 990 900 1.120 B B 624 600 874 C 354 348 440 D 336 320 400 C D F E E 396 400 528 F 366 360 494 H 966 1.327 1.558

Mini VRF 15 Technical features Model Outdoor unit SYSVRF 080 AIR EVO HP Q 120 AIR EVO HP Q 140 AIR EVO HP R 160 AIR EVO HP R 180 AIR EVO HP R 224 AIR EVO HP R Art. no. 314392 314089 314092 314094 314777 314778 Power supply V/Ph/Hz 220-240/1/50 380-415/3+N/50 Cooling capacity Nom / Eurovent kw 8,0 / 7,2 12,3 / 12,3 14,0 / 14,0 15,5 / 15,5 17,5 / 17,5 22,4 / - Power input Nom / Eurovent kw 2,05 / 1,85 3,25 / 3,25 3,95 / 3,95 4,52 / 4,52 5,30 / 5,30 6,80 / - EER Nom / Eurovent kw/ kw 3,9 / 3,9 3,78 / 3,78 3,54 / 3,54 3,43 / 3,43 3,30 / 3,30 3,29 / - SEER/SCOP 5,1 / 3,8 7,1 / 4,11 6,68 / 3,96 6,42 / 3,83 6,21 / 3,92 6,21 / - Heating capacity Nom / Eurovent kw 9,0 / 7,2 13,2 / 13,2 15,4 / 15,4 17,0 / 17,0 19,0 / 19,0 24,5 / - Power input Nom / Eurovent kw 2,24 / 1,79 3,47 / 3,47 4,16 / 4,16 4,77 / 4,78 5,0 / 5,0 5,90 / - COP Nom / Eurovent kw/ kw 4,02 / 4,02 3,80 / 3,80 3,70 / 3,70 3,56 / 3,56 3,80 / 3,80 4,15 / - Max. current A 18,5 24,4 11,0 12,0 12,5 17,2 Compressor Fan Quantity pcs 1 DC Inverter/ Rotary Start-up method Soft start Refrigerant oil ml 670+200 870+630 870+630 1.400+250 1.400+250 1.700+1.500 Type/motor 1 Axial / 1 DC motor 2 Axial / DC motor Air flow m3/h 5.500 6.000 6.800 10.500 Sound power level db(a) 67 70 71 72 74 74 Sound pressure level db(a) 56 57 57 57 59 59 Refrigerant Type R410A Factory charge kg 2,95 3,3 3,9 3,9 4,5 6,2 Dimension (LxWxH) mm 1.075x396x966 900x400x1.327 1.120x528x1.558 Packing (LxWxH) mm 1.120x435x1100 1.030x435x1.456 1.270x565x1.720 Net/gross weight kg 62/67 95/106 95/106 100/111 107/118 147/163 Piping dimension Liquid pipe mm (in) 9,5 (3/8") 9,5 (3/8") Gas pipe mm (in) 15,9 (5/8") 19,1 (3/4") Max quantity indoor units connection pcs 4 6 6 7 9 11 Operating ambient temperature range C Cooling -15 +46 / Heating -15 +27 Eurovent data are defined for combination ratio equals to 100% and for Duct indoor units. Operating conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB, 24 C WB 5 m 0 m Heating mode 20 C DB, 15 C WB 7 C DB, 6 C WB 5 m 0 m The sound pressure value may vary depending on ambient conditions. Piping Lenght Maximum piping equivalent lenght. Maximum piping (the farthest IDU from the first indoor unit branch) equivalent lenght. 100 m Maximum outdoor unit-indoor unit drop height. 30 m 8 m Maximum indoor unit to indoor unit drop height. 20 m Outdoor units SYSVRF AIR EVO HP Piping lenght Drop height Total piping lenght (actual) Maximum piping Piping (the farthest IDU from the first indoor unit branch) equivalent lenght Outdoor unit-indoor unit drop height Indoor unit to indoor unit drop height Permitted value 100 m Actual lenght 60 m (45 m SYSVRF 080) Equivavent lenght 70 m (50 m SYSVRF 080) Outdoor unit up Outdoor unit down 20 m 30 m 20 m 8 m

16 VRF Heat Pump Modular VRF Heat Pump Outdoor Units SYSVRF AIR EVO HP Features Wide application area due to incredible piping length and wide operating temperature range. Free modular combination of 4 basic units, up to a total capacity of maximum 246 kw. Top class energy efficiency. DC Inverter Scroll compressor provinding wide capacity output from 10% to 100% evenly. All DC fan motor. High performance of the new designed heat exchanger. External static pressure up to 60 Pa (factory option, 20 Pa standard). Maximum indoor unit connection. Indoor unit combination total capacity index from 50% to 130%. Centralized control, BMS connection and web access potential. SYSVRF 252-280-335 AIR EVO HP R SYSVRF 400-450-500-560-615 AIR EVO HP R Dimensions SYSVRF 252/280/335 AIR EVO HP R SYSVRF 400/450/500/560/615 AIR EVO HP R 1250 1635 990 790 765 1615

VRF Heat Pump 17 Technical features Model Outdoor unit SYSVRF 252 AIR EVO HP R 280 AIR EVO HP R 335 AIR EVO HP R 400 AIR EVO HP R 450 AIR EVO HP R 500 AIR EVO HP R 560 AIR EVO HP R 615 AIR EVO HP R Art. no. 314744 314745 314746 314747 314749 314750 314775 314776 Power supply V/Ph/Hz 380-415/3+N/50 or 60 Cooling capacity Nom/Eurovent kw 25,2 / 25,2 28 / 28 33,5 / 33,5 40 / 40 45 / 45 50 / 50 56 / 56 61,5 / 61,5 Power input Nom/Eurovent kw 5,36 / 6,25 6,22 / 7,49 7,79 / 8,91 9,3 / 11,7 10,98 / 13,6 12,82 / 14,7 14,51 / 16,5 16,44 / 19,8 EER Nom/Eurovent kw/ kw 4,7 / 4,03 4,5 / 3,74 4,3 / 3,76 4,3 / 3,43 4,1 / 3,30 3,9 / 3,40 3,86 / 3,40 3,74 / 3,10 SEER/SCOP 8,25 / 6,52 7,90 / 6,35 7,54 / 6,13 7,54 / 6,03 7,20 / 5,82 7,36 / 5,67 7,28 / 5,50 7,04 / 5,25 Heating capacity Nom/Eurovent kw 27 / 27 31,5 / 31,5 37,5 / 37,5 45 / 40 50 / 45 56 / 50 63 / 56 69 / 61,5 Power input Nom/Eurovent kw 4,82 / 5,30 5,94 / 6,89 7,65 / 8,91 9,38 / 9,83 10,87 / 11,69 13,18 / 12,5 15,29 / 14,0 17,12 / 16,2 COP Nom/Eurovent kw/ kw 5,6 / 5,09 5,3 / 4,57 4,9 / 4,21 4,8 / 4,07 4,6 / 3,85 4,25 / 4,00 4,12 / 4,00 4,03 / 3,80 Max. current A 25,6 25,6 27,5 35,2 35,2 42,4 53,4 53,4 Compressor Fan Quantity pcs 1 DC Inverter/ Scroll 2 DC Inverter/ Scroll Start-up method Soft start Refrigerant oil ml 500 2x500 Type/motor 1 Axial / DC motor 2 Axial / DC motor Static pressure Pa 0-20 (20-60 factory option) 0-20 (20-60 factory option) Air flow m3/h 12.000 12.000 12.000 14.000 14.000 16.000 16.000 16.000 Sound power level db(a) 79 83 82 88 88 88 88 88 Sound pressure level db(a) 59 63 62 66 66 66 66 66 Refrigerant Type/ motor Factory charge kg 9 9 11 13 13 13 16 16 R410A Dimension (LxWxH) mm 990x790x1635 1340x790x1635 Packing (LxWxH) mm 1055x855x1805 1405x855x1805 Net/gross weight kg 219/234 219/234 237/252 297/315 297/315 305/323 340/358 340/358 Piping dimension Liquid pipe mm (in) 12,7 (1/2") 15,9 (5/8") Gas pipe mm (in) 25,4 (1") 31,8 (1 1/4") Max quantity indoor units connection pcs 13 16 20 23 26 29 33 36 Operating ambient temperature range C Cooling -15 +48 / Heating -20 +24 Eurovent data are defined for combination ratio equals to 100% and for Duct indoor units. Operating conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB, 24 C WB 5 m 0 m Heating mode 20 C DB, 15 C WB 7 C DB, 6 C WB 5 m 0 m The sound pressure value may vary depending on ambient conditions. Piping Lenght Maximum piping equivalent lenght. Maximum piping (the farthest IDU from the first indoor unit branch) equivalent lenght. Maximum outdoor unit-indoor unit drop height. Maximum indoor unit to indoor unit drop height. Outdoor units SYSVRF 252 to 2000 AIR EVO HP R Piping lenght Drop height Total piping lenght (actual) Maximum piping Actual lenght Equivavent lenght Piping (the farthest IDU from the first indoor unit branch) equivalent lenght Outdoor unit-indoor unit drop height Indoor unit to indoor unit drop height Outdoor unit down Outdoor unit up Permitted value 1.000 m 175 m 200 m 40 m/90 m* 110 m 90 m 30 m * When the farthest pipe length is more than 40m, it needs to meet specific conditions according to the installation part of the technical manual.

18 VRF Heat Pump combination Outdoor unit combination SYSVRF AIR EVO HP Design Cooling/ Heating capacity kw Model Recommended combination Outdoor branch Max. indoor unit qty 25,2/27 SYSVRF 252 AIR EVO HP R SYSVRF 252 AIR EVO HP R - 13 28/31,5 SYSVRF 280 AIR EVO HP R SYSVRF 280 AIR EVO HP R - 16 33,5/37,5 SYSVRF 335 AIR EVO HP R SYSVRF 335 AIR EVO HP R - 20 40/45 SYSVRF 400 AIR EVO HP R SYSVRF 400 AIR EVO HP R - 23 45/50 SYSVRF 450 AIR EVO HP R SYSVRF 450 AIR EVO HP R - 26 50/56 SYSVRF 500 AIR EVO HP R SYSVRF 500 AIR EVO HP R - 29 56/63 SYSVRF 560 AIR EVO HP R SYSVRF 560 AIR EVO HP R - 33 61,5/69 SYSVRF 615 AIR EVO HP R SYSVRF 615 AIR EVO HP R - 36 67/75 SYSVRF 670 AIR EVO HP R SYSVRF 335 AIR EVO HP R x2 OUT 02 HP 39 73/81,5 SYSVRF 730 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 450 AIR EVO HP R OUT 02 HP 43 78/87,5 SYSVRF 780 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 500 AIR EVO HP R OUT 02 HP 46 84/94,5 SYSVRF 840 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 560 AIR EVO HP R OUT 02 HP 50 89,5/100,5 SYSVRF 895 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 615 AIR EVO HP R OUT 02 HP 53 95/106 SYSVRF 950 AIR EVO HP R SYSVRF 335 AIR EVO HP R + SYSVRF 615 AIR EVO HP R OUT 02 HP 56 100/112 SYSVRF 1000 AIR EVO HP R SYSVRF 500 AIR EVO HP R x2 OUT 02 HP 59 106,5/119 SYSVRF 1065 AIR EVO HP R SYSVRF 450 AIR EVO HP R + SYSVRF 615 AIR EVO HP R OUT 02 HP 63 111,5/125 SYSVRF 1115 AIR EVO HP R SYSVRF 500 AIR EVO HP R + SYSVRF 615 AIR EVO HP R OUT 02 HP 117,5/132 SYSVRF 1175 AIR EVO HP R SYSVRF 560 AIR EVO HP R + SYSVRF 615 AIR EVO HP R OUT 02 HP 123/138 SYSVRF 1230 AIR EVO HP R SYSVRF 615 AIR EVO HP R x2 OUT 02 HP

VRF Heat Pump combination 19 Design Cooling/ Heating capacity kw Model Recommended combination Outdoor branch Max. indoor unit qty 128,5/144 SYSVRF 1285 AIR EVO HP R SYSVRF 335 AIR EVO HP R x2 + SYSVRF 615 AIR EVO HP R OUT 03 HP 134,5/150,5 SYSVRF 1345 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 450 AIR EVO HP R + SYSVRF 615 AIR EVO HP R OUT 03 HP 139,5/156,5 SYSVRF 1395 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 500 AIR EVO HP R + SYSVRF 615 AIR EVO HP R OUT 03 HP 145,5/163,5 SYSVRF 1455 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 560 AIR EVO HP R + SYSVRF 615 AIR EVO HP R OUT 03 HP 151/169,5 SYSVRF 1510 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 615 AIR EVO HP R x2 OUT 03 HP 156,5/175,5 SYSVRF 1565 AIR EVO HP R SYSVRF 335 AIR EVO HP R + SYSVRF 615 AIR EVO HP R x2 OUT 03 HP 161,5/181 SYSVRF 1615 AIR EVO HP R SYSVRF 500 AIR EVO HP R x2 + SYSVRF 615 AIR EVO HP R OUT 03 HP 168/188 SYSVRF 1680 AIR EVO HP R SYSVRF 450 AIR EVO HP R + SYSVRF 615 AIR EVO HP R x2 OUT 03 HP 173/194 SYSVRF 1730 AIR EVO HP R SYSVRF 500 AIR EVO HP R + SYSVRF 615 AIR EVO HP R x2 OUT 03 HP 179/201 SYSVRF 1790 AIR EVO HP R SYSVRF 560 AIR EVO HP R + SYSVRF 615 AIR EVO HP R x2 OUT 03 HP 184,5/207 SYSVRF 1845 AIR EVO HP R SYSVRF 615 AIR EVO HP R x3 OUT 03 HP 190/213 SYSVRF 1900 AIR EVO HP R SYSVRF 335 AIR EVO HP R x 2 + SYSVRF 615 AIR EVO HP R x 2 OUT 04 HP 196/219,5 SYSVRF 1960 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 450 AIR EVO HP R + SYSVRF 615 AIR EVO HP R x 2 OUT 04 HP 201/219,5 SYSVRF 2010 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 500 AIR EVO HP R + SYSVRF 615 AIR EVO HP R x 2 OUT 04 HP 207/232,5 SYSVRF 2070 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 560 AIR EVO HP R + SYSVRF 615 AIR EVO HP R x 2 OUT 04 HP 212,5/238,5 SYSVRF 2125 AIR EVO HP R SYSVRF 280 AIR EVO HP R + SYSVRF 615 AIR EVO HP R x 3 OUT 04 HP 218/244,5 SYSVRF 2180 AIR EVO HP R SYSVRF 335 AIR EVO HP R + SYSVRF 615 AIR EVO HP R x 3 OUT 04 HP 223/250 SYSVRF 2230 AIR EVO HP R SYSVRF 500 AIR EVO HP R x 2 + SYSVRF 615 AIR EVO HP R x 2 OUT 04 HP 229,5/257 SYSVRF 2295 AIR EVO HP R SYSVRF 450 AIR EVO HP R + SYSVRF 615 AIR EVO HP R x 3 OUT 04 HP 234,5/263 SYSVRF 2345 AIR EVO HP R SYSVRF 500 AIR EVO HP R + SYSVRF 615 AIR EVO HP R x 3 OUT 04 HP 240,5/270 SYSVRF 2405 AIR EVO HP R SYSVRF 560 AIR EVO HP R + SYSVRF 615 AIR EVO HP R x 3 OUT 04 HP 246/276 SYSVRF 2460 AIR EVO HP R SYSVRF 615 AIR EVO HP R x 4 OUT 04 HP

20 VRF Heat Recovery Modular VRF Heat Recovery Outdoor Units SYSVRF AIR EVO HR Features Simultaneous operation in cooling and heating mode provides more comfort and reduces power consumption. Wide application area due to incredible piping lenght and wide operating temperature range. Free modular combination of 5 basic units, up to a total capacity of maximum 180 kw. Top class energy efficiency. All DC Inverter Scroll compressors providing wide capacity output from 10% to 100% evenly. DC fan motor. High performance of the new designed heat exchanger with double refrigerant circuit. External static pressure up to 40 Pa (20 Pa standard). Maximum indoor unit connection. Indoor unit combination total capacity index from 50% to 130%. Centralized control, BMS connection and web access potential. Continuous heating output during defrost operation thanks to the innovative double heat exchanger. 1250 Dimensions SYSVRF 252/280/335/400/450 AIR EVO HR R 1250 1615 765 1615

VRF Heat Recovery 21 Technical features Model Outdoor unit SYSVRF 252 AIR EVO HR R 280 AIR EVO HR R 335 AIR EVO HR R 400 AIR EVO HR R 450 AIR EVO HR R Art. no. 314084 314085 314086 314087 314088 Power Supply V/Ph/Hz 380-415/3+N/50 or 60 Cooling capacity Nom/Eurovent kw 25,2 /25,2 28,0 / 28,0 33,5 / 33,5 40,0 / 40,0 45,0 / 45,0 Power Input Nom/Eurovent kw 5,73 / 5,97 6,67 / 6,75 8,07 / 9,28 11,30 / 11,5 13,24 / 14,2 EER Nom/Eurovent kw/ kw 4,40 / 4,42 4,20 / 4,15 4,15 / 3,61 3,54 / 3,48 3,40 / 3,17 SEER/SCOP 7,53 / 6,23 7,43 / 6,05 7,40 / 6,02 6,68 / 5,67 6,38 / 5,45 Heating capacity Nom/Eurovent kw 27,0 / 27,0 31,5 / 31,5 37,5 / 37,5 45 / 40 50 / 45 Power Input Nom/Eurovent kw 6,0 / 5,02 7,33 / 6,21 8,72 / 9,24 11,19 / 9,76 12,79 / 11,9 COP Nom/Eurovent kw/ kw 4,50 / 5,38 4,30 / 5,07 4,30 / 4,06 4,02 / 4,10 3,91 / 3,78 Max. current A 20,8 22,1 22,8 31,8 32,8 Compressor Fan Quantity pcs 1 DC Inverter / Scroll 2 DC Inverter / Scroll Start-up method Soft start Refrigerant oil ml 500 2X500 Type/motor 2 Axial / DC motor Static pressure Pa 0-20 (0-40 factory option) Air flow m 3 /h 12.000 12.000 13.000 15.000 15.000 Sound power level db(a) 79 83 84 88 88 Sound pressure level db(a) 57 57 58 60 60 Refrigerant Type/motor R410A Factory charge kg 10 10 10 13 13 Dimension (LxWxH) mm 1.250x765x1.615 1.250x765x1.615 Packing (LxWxH) mm 1.305x825x1.790 1.350x825x1.790 Net/gross weight kg 255/273 303/322 Piping dimension Liquid pipe mm (in) 12,7 (1/2 ) 15,9 (5/8 ) Low pressure gas pipe mm (in) 22,2 (7/8 ) 25,4 (1 ) 28,6 (1 1/8 ) High pressure gas pipe mm (in) 19,1 (3/4 ) 22,2 (7/8 ) Oil balance pipe mm (in) 6,35 (1/4 ) Gas balance pipe mm (in) 19,1 (3/4") Max quantity indoor units connection pcs 13 16 20 23 26 Operating ambient temp. range C Cooling -5...+48 / Heating -20...+24 / Simultaneous Cooling and Heating -5...+24 Eurovent data are defined for combination ratio equals to 100% and for Duct indoor units. Operating conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB,24 C WB 7,5 m 0 m Heating mode 20 C DB, 15 C WB 7 C 7,5 m 0 m The sound pressure value may vary depending on ambient conditions. Piping Lenght Maximum piping equivalent lenght. Maximum piping (the farthest IDU from the first indoor unit branch) equivalent lenght. Maximum outdoor unit-indoor unit drop height. Maximum indoor unit to indoor unit drop height. Outdoor units SYSVRF 252 to 1800 AIR EVO HR R Piping lenght Drop height Total piping lenght (actual) Maximum piping Actual lenght Aquivavent lenght Piping (the farthest IDU from the first indoor unit branch) equivalent lenght Outdoor unit-indoor unit drop height Indoor unit to indoor unit drop height Outdoor unit up Outdoor unit down Permitted value 1.000 m 175 m 200 m 40 m/90 m* 110 m 70 m 30 m * When the farthest pipe length is more than 40m, it needs to meet specific conditions according to the installation part of the technical manual.

22 VRF Heat Recovery switch module Mode Switch module for VRF Heat Recovery systems SYSVRF BOX HR Features Simultaneous heating and cooling in a single refrigerant system thanks to the combination of SYSVRF HR outdoor units and the SYSVRF BOX modules. SYSVRF BOX HR is available in 3 different modules with 2, 4 or 6 outlets and combination up to 24 indoor units from a single module. Compact and light design, it can be installed in narrow space. Independent sub-cooling circuit for each SYSVRF BOX HR module. SYSVRF BOX 02 HR SYSVRF BOX 04 HR SYSVRF BOX 06 HR Heating Heating Heating Off Cooling Cooling Dimensions SYSVRF BOX SYSVRF BOX 02 HR SYSVRF BOX 04 HR SYSVRF BOX 06 HR A 630 960 960 B 600 600 600 C 225 225 225 D 490 820 820 E 300 300 300

VRF Heat Recovery switch module 23 Technical features Model SYSVRF BOX 02 HR SYSVRF BOX 04 HR SYSVRF BOX 06 HR Art. no. 314161 314162 314186 Power Supply V/Ph/Hz 220-240/1/50 or 60 Max indoor unit groups 2 4 6 Max number of each group indoor units 4 4 4 Max number of all downstream indoor units 4x2=8 4x4=16 4x6=24 Max capacity of each group indoor units kw 16 16 16 Total capacity of all downstream indoor units kw <28 <45 <45 Piping connections Connect to outdoor unit Connect to indoor unit Liquid pipe mm (in) 12,7 (1/2 ) 15,9 (5/8 ) 15,9 (5/8 ) High pressureg gas pipe mm (in) 19,1 (3/4 ) 22,2 (7/8 ) 22,2 (7/8 ) Low pressure gas pipe mm (in) 25,4 (1 ) 31,8 (1 1/4 ) 31,8 (1 1/4 ) Liquid pipe mm (in) 9,5 (3/8 ) 9,5 (3/8 ) 9,5 (3/8 ) Gas pipe mm (in) 15,9 (5/8 ) 15,9 (5/8 ) 15,9 (5/8 ) Dimension (LxWxH) mm 630x225x600 960x225x600 960x225x600 Packing (LxWxH) mm 725x325x685 1.055x325x685 1.055x325x685 Net/gross weight kg 19,5/27 31/40 35/44,5 Model SYSVRF BOX 02-1 HR SYSVRF BOX 04-1 HR Art. no. 313550 313551 Power Supply V/Ph/Hz 220-240/1/50 or 60 Max number of indoor unit 1 1 Max capacity of indoor unit kw 20-28 40-56 Piping connections Connect to outdoor unit Connect to indoor unit Liquid pipe mm (in) 12,7 (1/2 ) 15,9 (5/8 ) High pressure gas pipe mm (in) 19,1 (3/4 ) 22,2 (5/8 ) Low pressure gas pipe mm (in) 25,4 (1 ) 31,8 (1 1/4 ) Liquid pipe mm (in) 9,5 (3/8 ) 9,5 (3/8 ) Gas pipe mm (in) 15,9 (5/8 ) 15,9 (5/8 ) Dimension (LxWxH) mm 630x225x600 960x225x600 Packing (LxWxH) mm 725x325x685 1.055x325x685 Net/gross weight kg 19,5/27 31/40 Piping connections SYSVRF BOX SYSVRF BOX 02 HR SYSVRF BOX 04 HR SYSVRF BOX 06 HR Outdoor unit Indoor unit Liquid pipe 12,7 (1/2 ) 15,9 (5/8 ) 15,9 (5/8 ) High pressure pipe 19,1 (3/4 ) 22,2 (7/8 ) 22,2 (7/8 ) Low pressure pipe 25,4 (1 ) 31,8 (1 1/4 ) 31,8 (1 1/4 ) Liquid pipe 9,5 (3/8 ) 9,5 (3/8 ) 9,5 (3/8 ) Gas pipe 15,9 (5/8 ) 15,9 (5/8 ) 15,9 (5/8 )

24 VRF Heat Recovery combination Outdoor unit combination SYSVRF AIR EVO HR Design Cooling/ Heating capacity kw Model Recommended combination Outdoor branch Max. indoor unit qty 25,2/27 SYSVRF 252 AIR EVO HR R SYSVRF 252 AIR EVO HR R - 13 28/31,5 SYSVRF 280 AIR EVO HR R SYSVRF 280 AIR EVO HR R - 16 33,5/37,5 SYSVRF 335 AIR EVO HR R SYSVRF 335 AIR EVO HR R - 20 40/45 SYSVRF 400 AIR EVO HR R SYSVRF 400 AIR EVO HR R - 23 45/50 SYSVRF 450 AIR EVO HR R SYSVRF 450 AIR EVO HR R - 26 53,2/58,5 SYSVRF 532 AIR EVO HR R SYSVRF 252 AIR EVO HR R + SYSVRF 280 AIR EVO HR R OUT 02 HR 29 56/63 SYSVRF 560 AIR EVO HR R SYSVRF 280 AIR EVO HR R x2 OUT 02 HR 33 61,5/69 SYSVRF 615 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 335 AIR EVO HR R OUT 02 HR 36 68/76,5 SYSVRF 680 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 400 AIR EVO HR R OUT 02 HR 39 73/81,5 SYSVRF 730 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 450 AIR EVO HR R OUT 02 HR 43 80/90 SYSVRF 800 AIR EVO HR R SYSVRF 400 AIR EVO HR R x2 OUT 02 HR 46 85/95 SYSVRF 850 AIR EVO HR R SYSVRF 400 AIR EVO HR R + SYSVRF 450 AIR EVO HR R OUT 02 HR 50 90/100 SYSVRF 900 AIR EVO HR R SYSVRF 450 AIR EVO HR R x2 OUT 02 HR 53

VRF Heat Recovery combination 25 Design Cooling/ Heating capacity kw Model Recommended combination Outdoor branch Max. indoor unit qty 96/108 SYSVRF 960 AIR EVO HR R SYSVRF 280 AIR EVO HR R x2 + SYSVRF 400 AIR EVO HR R OUT 03 HR 56 101/113 SYSVRF 1010 AIR EVO HR R SYSVRF 280 AIR EVO HR R x2 + SYSVRF 450 AIR EVO HR R OUT 03 HR 59 106,5/119 SYSVRF 1065 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 335 AIR EVO HR R + SYSVRF 450 AIR EVO HR R OUT 03 HR 63 113/126,5 SYSVRF 1130 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 400 AIR EVO HR R + SYSVRF 450 AIR EVO HR R OUT 03 HR 120/135 SYSVRF 1200 AIR EVO HR R SYSVRF 400 AIR EVO HR R x3 OUT 03 HR 125/140 SYSVRF 1250 AIR EVO HR R SYSVRF 400 AIR EVO HR R x2 + SYSVRF 450 AIR EVO HR R OUT 03 HR 130/145 SYSVRF 1300 AIR EVO HR R SYSVRF 400 AIR EVO HR R + SYSVRF 450 AIR EVO HR R x2 OUT 03 HR 135/150 SYSVRF 1350 AIR EVO HR R SYSVRF 450 AIR EVO HR R x3 OUT 03 HR 143,2/158,5 SYSVRF 1432 AIR EVO HR R SYSVRF 252 AIR EVO HR R+ SYSVRF 280 AIR EVO HR R + SYSVRF 450 AIR EVO HR R x2 OUT 04 HR 146/163 SYSVRF 1460 AIR EVO HR R SYSVRF 280 AIR EVO HR R x2 + SYSVRF 450 AIR EVO HR R x2 OUT 04 HR 151,5/169 SYSVRF 1515 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 335 AIR EVO HR R + SYSVRF 450 AIR EVO HR R x2 OUT 04 HR 158/176,5 SYSVRF 1580 AIR EVO HR R SYSVRF 280 AIR EVO HR R + SYSVRF 400 AIR EVO HR R + SYSVRF 450 AIR EVO HR R x2 OUT 04 HR 165/185 SYSVRF 1650 AIR EVO HR R SYSVRF 400 AIR EVO HR R x3 + SYSVRF 450 AIR EVO HR R OUT 04 HR 170/190 SYSVRF 1700 AIR EVO HR R SYSVRF 400 AIR EVO HR R x2 + SYSVRF 450 AIR EVO HR R x2 OUT 04 HR 175/195 SYSVRF 1750 AIR EVO HR R SYSVRF 400 AIR EVO HR R + SYSVRF 450 AIR EVO HR R x3 OUT 04 HR 180/200 SYSVRF 1800 AIR EVO HR R SYSVRF 450 AIR EVO HR R x4 OUT 04 HR

26 VRF Heat Pump water-cooled Modular VRF Heat Pump Units SYSVRF WATER EVO HP Features Water-cooled VRF with DC Inverter compressor and pipe-in-pipe heat exchanger. Compact size and long piping system. High efficiency at partial load. Inverter Scroll compressor providing wide capacity output from 10% to 100% evenly. Centralized control, BMS connection and web access potential. Pipe-in-pipe heat exchanger assures excellent performance in heat trasfer and outstanding reliability. Piping connection in four different directions makes simple the installation of outdoor unit. Maximum 59 indoor units connection (100 kw modules). Indoor unit combination total capacity index from 50% to 130%. Dimensions 780 550 1000 52 198 45 32 152 95 176.5 55 50 30 620 20 52 444 52 112 70 326.5 61.5

VRF Heat Pump water-cooled 27 Technical features Model Outdoor unit SYSVRF 252 WATER EVO HP R 280 WATER EVO HP R 335 WATER EVO HP R Art. no. 314247 314248 314249 Power Supply V/Ph/Hz 380-415/3+N/50 Cooling capacity kw 25,2 28,0 33,5 Power Input kw 4,80 6,10 8,00 EER 5,25 4,59 4,19 Heating capacity kw 27,0 31,5 37,5 Power Input kw 4,45 5,83 7,80 COP 6,07 5,40 4,81 Compressor Inverter Scroll Quantity pcs 1 Crankcase heater W 40-80 40-80 40-80 Refrigerant oil ml 500 500 500 Water flow m 3 /h 5,4 6,0 7,2 Pressure drop kpa 35 40 48 Sound pressure level db(a) 51 52 52 Refrigerant Type R410A Refrigerant charge kg 2,0 2,0 2,0 Dimension LxWxH mm 780x1.000x550 Packing LxWxH mm 845x1.170x600 Net/gross weight kg 146/155 140/155 147/156 Piping dimension Liquid pipe mm (in) 9,53 (3/8 ) 9,53 (3/8 ) 12,7 (1/2 ) Gas pipe mm (in) 22,2 (7/8 ) 22,2 (7/8 ) 25,4 (1 ) Oil balance pipe mm (in) 6,35 (1/4 ) Water side pipe mm 31,8 Max qty. indoor units connection pcs 13 16 20 Operating conditions Indoor unit Module water inlet Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 30 C DB 5 m 0 m Heating mode 20 C DB, 15 C WB 20 C DB 5 m 0 m The sound pressure value may vary depending on ambient conditions. Piping Lenght Maximum piping equivalent lenght. Maximum piping (the farthest IDU from the first indoor unit branch) equivalent lenght. 100 m Maximum outdoor unit-indoor unit drop height. 30 m 8 m Maximum indoor unit to indoor unit drop height. 20 m Modules SYSVRF WATER EVO HP Piping lenght Drop height Total piping lenght (actual) Maximum piping Actual lenght Equivavent lenght Piping (the farthest IDU from the first indoor unit branch) equivalent lenght Module indoor unit drop height Indoor unit to indoor unit drop height Module up Module down Permitted value 300 m 120 m 150 m 40 m 50 m 40 m 30 m

28 VRF water-cooled combination Unit combination SYSVRF WATER EVO HP Design Cooling/ Heating capacity kw Model Recommended combination Outdoor branch Max. indoor unit qty 25,2/27 28/31,5 33,5/37,5 SYSVRF 252 WATER EVO HP R SYSVRF 280 WATER EVO HP R SYSVRF 335 WATER EVO HP R SYSVRF 252 WATER EVO HP R - 13 SYSVRF 280 WATER EVO HP R - 16 SYSVRF 335 WATER EVO HP R - 20 50,4/54 SYSVRF 504 WATER EVO HP R SYSVRF 252 WATER EVO HP R x2 OUT 02 HP 26 53,2/58,5 SYSVRF 532 WATER EVO HP R SYSVRF 252 WATER EVO HP R + SYSVRF 280 WATER EVO HP R OUT 02 HP 29 56/63 SYSVRF 560 WATER EVO HP R SYSVRF 280 WATER EVO HP R x2 OUT 02 HP 33 61,5/69 SYSVRF 615 WATER EVO HP R SYSVRF 280 WATER EVO HP R + SYSVRF 335 WATER EVO HP R OUT 02 HP 36 67/75 SYSVRF 670 WATER EVO HP R SYSVRF 335 WATER EVO HP R x2 OUT 02 HP 39

VRF water-cooled combination 29 Design Cooling/ Heating capacity kw Model Recommended combination Outdoor branch Max. indoor unit qty 78,4/85,5 SYSVRF 784 WATER EVO HP R SYSVRF 232 WATER EVO HP R x2 + SYSVRF 280 WATER EVO HR R OUT 03 HP 43 81,2/90 SYSVRF 812 WATER EVO HP R SYSVRF 252 WATER EVO HP R + SYSVRF 280 WATER EVO HP R x2 OUT 03 HP 46 84/94,5 SYSVRF 840 WATER EVO HP R SYSVRF 280 WATER EVO HP R x3 OUT 03 HP 50 89,5/100,5 SYSVRF 895 WATER EVO HP R SYSVRF 280 WATER EVO HP R x2 + SYSVRF 335 WATER EVO HP R OUT 03 HP 53 95/106,5 SYSVRF 950 WATER EVO HP R SYSVRF 280 WATER EVO HP R + SYSVRF 335 WATER EVO HP R x2 OUT 03 HP 56 100,5/112,5 SYSVRF 1005 WATER EVO HP R SYSVRF 335 WATER EVO HP R x3 OUT 03 HP 59

30 VRF Wall indoor units Wall-Mounted Indoor Units SYSVRF WALL Features Front panel of modern design that fits into any interior decor. All models are equipped with high efficient DC fan motor. Even and smooth air distribution due to auto swing function. Multi-refrigerant outlet pipe method: left/right/rear, more flexible for installation. Washable air filter, easy for insertion and removal. Built-in electronic expansion valve (EXV) ensuring precise flow control. Infrared receiver and remote SYS RM 02 with address setting function as standard equipment. Power supply 50Hz or 60Hz. Infrared remote control SYS RM 02 (standard) Wired controller SYS WC 29 Art. no. 314772 (optional) Accessories/option Wired controller SYS WC 29 with address setting function for heat pump system. Wired controller SYS WC 120 for heat recovery system. Wired controller SYS WC 120 Art. no. 314774 (optional) Dimensions SYSVRF WALL 22/28 Q SYSVRF WALL 71/80 Q 54 343 280 203 50 9 835 262 56 12 1194 SYSVRF WALL 36/45/56 Q 60 315 223 45 15 990

VRF Wall indoor units 31 Technical features Model Indoor unit SYSVRF WALL 22 Q WALL 28 Q WALL 36 Q WALL 45 Q WALL 56 Q WALL 71 Q WALL 80 Q Art. no. 314767 314768 314769 314770 314771 314785 314786 Power Supply V/Ph/Hz 220-240/1/50 or 60 Cooling capacity kw 2,2 2,8 3,6 4,5 5,6 7,1 8,0 Power input kw 8 9 19 19 27 49 53 Current 0,27 0,31 0,43 0,44 0,58 0,60 0,60 Heating capacity kw 2,4 3,2 4,0 5,0 6,3 8,0 9,0 Power input kw 8 9 19 19 27 49 53 Current 0,27 0,31 0,43 0,44 0,58 0,60 0,60 Indoor fan motor DC motor DC motor Air flow (H/M/L) m 3 /h 420/390/360 420/370/320 660/570/490 590/510/420 750/650/550 1.200/1.000/810 Sound pressure level (H/M/L) db(a) 31/30/29 31/30/29 33/32/30 35/33/31 38/36/34 44/39/36 Dimension LxWxH mm 835x203x280 990x223x315 1.194x262x343 Packing LxWxH mm 935x320x385 1.085x335x420 1.290x375x460 Net/gross weight kg 8,4/12,1 9,5/13,1 11,4/15,5 12,8/16,9 12,8/16,9 17,0/22,4 Refrigerant R410A R410A Piping dimension Liquid pipe mm (in) 6,4 (1/4") 9,5 (3/8") Gas pipe mm (in) 12,7 (1/2") 15,9 (5/8") Drain piping mm 16,5 16,5 Operating ambient temp. range C Cooling +17 +32 / Heating +10 +28 Operating conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 8 m 0 m Heating mode 20 C DB, 15 C WB 7 C 8 m 0 m The sound pressure value may vary depending on ambient conditions.

32 VRF Compact Cassette indoor units Compact Cassette Indoor Units SYSVRF MINI Features New grille SYSPANEL MINI VRF with 360 air discharge providing strong circulating air flow to cool or heat every corner of the room. Compact casing making it match perfectly with ambient decoration. Advanced 3D spiral fan design reducing the air resistance and operation noise. All models are equipped with high efficient DC fan motor. Integrated drain pump with a head of 500 mm. Fresh air hole and reserved ports for duct connection. Built-in electronic expansion valve (EXV) ensuring precise flow control. Infrared receiver and remote SYS RM 02 with address setting function as standard equipment. Power supply 50Hz or 60Hz. Accessories/option Wired controller SYS WC 29 with address setting function for heat pump system. Wired controller SYS WC 120 for heat recovery system. Dimensions Drain point Connecting points of refrigerant pipe (gas/liquid side) Infrared remote control SYS RM 02 (standard) 60 Wired controller SYS WC 120 Art. no. 314774 (optional) 545 570 523 Wired controller SYS WC 29 Art. no. 314772 (optional) 570 7 (panel) Drain point Connecting points of refrigerant pipe (gas/liquid side) 7 (panel) 523 570 7 (panel) 60 Main body Nut Hook 260 545 Ceiling 50 600 Panel 570 7 (panel)

VRF Compact Cassette indoor units 33 Technical features Model Indoor unit Model Panel unit SYSVRF SYSPANEL MINI 15 Q MINI VRF MINI 22 Q MINI VRF MINI 28 Q MINI VRF MINI 36 Q MINI VRF MINI 45 Q MINI VRF MINI 56 Q MINI VRF Art. no. Indoor unit 314779 314751 314752 314753 314754 314755 Art. no. Panel unit 313324 313324 313324 313324 313324 313324 Power Supply V/Ph/Hz 220-240/1/50 or 60 Cooling capacity kw 1,5 2,2 2,8 3,6 4,5 5,6 Power Input W 14 15 16 21 Current A 0,23 0,26 0,28 Indoor fan motor DC motor Heating capacity kw 1,7 2,4 3,2 4,0 5,0 6,0 Power Input W 11 13 18 Current A 0,23 0,26 0,28 Air flow (H/M/L) m 3 /h 526/449/3 576/503/405 604/516/400 Sound pressure level (H/M/L) db(a) 34/33/22 35/32/22 35/32/22 41,5/35,6/28,8 Unit Panel Refrigerant Piping dimension Dimension (LxWxH) mm 570x570x260 Packing (LxWxH) mm 675x675x285 Net/gross weight kg 16/22 17,5/23,5 Dimension (LxWxH) mm 7x7x50 Packing (LxWxH) mm 715x715x113 Net/gross weight kg 3/5 R410A Liquid pipe mm (in) 6,4 (1/4 ) 9,5 (3,8 ) Gas pipe mm (in) 12,7 (1/2 ) 15,9 (5/8 ) Drain piping mm 25 Operating ambient temp. range C Cooling +17...+32 / Heating +10...+28 Operating conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 8 m 0 m Heating mode 20 C DB, 15 C WB 7 C 8 m 0 m The sound pressure value may vary depending on ambient conditions.

34 VRF Cassette indoor units Standard Cassette Indoor Units SYSVRF Features New grille SYSPANEL EVO with 360 air discharge providing strong circulating air flow to cool or heat every corner of the room. Ultra-thin casing for easy installation into a shallow ceiling. Advanced 3D spiral fan design reducing the air resistance and operation noise. All models are equipped with high efficient DC fan motor. Integrated drain pump with a head of 750 mm. Fresh air hole and reserved ports for duct connection. Built-in electronic expansion valve (EXV) ensuring precise flow control. Infrared receiver and remote SYS RM 02 with address setting function as standard equipment. Power supply 50Hz or 60Hz. Accessories/option Wired controller SYS WC 29 with address setting function for heat pump system. Wired controller SYS WC 120 for heat recovery system. Infrared remote control SYS RM 02 (standard) Wired controller SYS WC 120 Art. no. 314774 (optional) Wired controller SYS WC 29 Art. no. 314772 (optional) Dimensions 950 780 A 105 Φ32 Drain pipe outter diameter 70 950 680 55 840 20 146 B Φ75 New air supply orifice 840 904 Ceiling Panel Main body 46 Indoor unit SYSVRF 28 Q 36 Q 45 Q 56 Q 71 Q 90 Q 112 Q A mm 230 230 300 B mm 170 170 190 140 Q

VRF Cassette indoor units 35 Technical features Model Indoor unit Model Panel unit SYSVRF SYSPANEL 28 Q EVO VRF 36 Q EVO VRF 45 Q EVO VRF 56 Q EVO VRF 71 Q EVO VRF 90 Q EVO VRF 112 Q EVO VRF 140 Q EVO VRF Art. no. Indoor unit 314756 314757 314758 314759 314760 314255 314256 314257 Art. no. Panel unit 313728 313728 313728 313728 313728 313728 313728 313728 Power Supply V/Ph/Hz 220-240/1/50 or 60 Cooling capacity kw 2,8 3,6 4,5 5,6 7,1 9,0 11,2 14,0 Power Input W 25 31 46 75 94 Current A 0,32 0,34 0,36 0,82 0,98 Indoor fan motor DC motor Heating capacity kw 3,2 4,0 5,0 6,3 8,0 10,0 12,5 15,0 Power Input W 25 31 46 75 94 Current A 0,32 0,34 0,36 0,82 0,98 Air flow (H/M/L) m 3 /h 982/832/677 1029/857/704 1200/996/ 748 1596/1239/1034 1727/1426/ 1224 Sound pressure level (H/M/L) db(a) 42/37/32 43/38/34 45/39/34 47/41/36 50/45/35 Dimension (LxWxH) mm 840x840x230 840x840x300 Unit Packing (LxWxH) mm 955x955x247 955x955x317 Net/gross weight kg 24/28 26/30 32/37 Dimension (LxWxH) mm 950x950x46 Panel Packing (LxWxH) mm 1.000x1.000x60 Net/gross weight kg 6/8 Refrigerant R410A Piping dimension Liquid pipe mm (in) 6,4 (1/4 ) 9,5 (3/8 ) Gas pipe mm (in) 12,7 (1/2 ) 15,9 (5/8 ) Drain piping mm 32 Operating ambient temp. range C Cooling +17...+32 / Heating +10...+28 Operating conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 8 m 0 m Heating mode 20 C DB, 15 C WB 7 C 8 m 0 m The sound pressure value may vary depending on ambient conditions.

36 VRF Cassette 1way indoor units Cassette 1Way Indoor Unit SYSVRF 1W Features Stylish look with new decorative panel. Ultra-thin chassis for easy installation in false ceiling. Integrated drain pump with a head of 750mm. Built-in electronic expansion valve (EXV) ensuring precise flow control. Infrared receiver and remote controller SYS RM 02. With address setting function as standard equipment. Power supply 50Hz. Accessories/option Wired controller SYS WC 29 with address setting function for heat pump system. Wired controller SYS WC 120 for heat recovery system. Infrared remote control SYS RM 02 (standard) Wired controller SYS WC 120 Art. no. 314774 (optional) Wired controller SYS WC 29 Art. no. 314772 (optional) Dimensions 1015 290

VRF Cassette 1way indoor units 37 Technical features Model Indoor unit Model Panel unit SYSVRF SYSPANEL 1W 18 Q 1W VRF 1W 22 Q 1W VRF 1W 28 Q 1W VRF 1W 36 Q 1W VRF 1W 45 Q 1W VRF L 1W 56 Q 1W VRF L 1W 71 Q 1W VRF L Art. no. Indoor unit 314213 314214 314215 314216 314780 314781 314782 Art. no. Panel unit 314217 314783 Power Supply V/Ph/Hz 220-240/1/50 Cooling capacity kw 1,8 2,2 2,8 3,6 4,5 5,6 7,1 Power Input W 41 48 48 60 Current A 0,24 0,25 0,27 0,32 0,36 Heating capacity kw 2,2 2,6 3,2 4,0 5,0 6,3 8,0 Power Input W 41 43 44 55 Current A 0,24 0,25 0,27 0,32 0,36 Indoor fan motor AC motor Air flow (H/M/L) m 3 /h 523/404/275 573/456/315 693/600/476 792/688/549 933/749/592 Sound pressure level (H/M/L) db(a) 37/34/30 38/34/30 39/37/34 40/38/34 41/39/35 42/40/36 44/41/37 Unit Panel Refrigerant Piping dimension Dimension (LxWxH) mm 1.054 425 153 1.204x443x189 Packing (LxWxH) mm 1.155x490x245 1.370x505x295 Net/gross weight kg 12,5/16 13/16,5 18,5/23,2 18,8/23,5/19,5/24,2 Dimension (LxWxH) mm 1.180x465x25 1.350x505x25 Packing (LxWxH) mm 1.232 517 107 1410x560x95 Net/gross weight kg 3,5/5,2 3,5/5,2 4/5,4 4/5,4 R410A Liquid pipe mm (in) 6,4 (1/4 ) 9,5 (3/8 ) Gas pipe mm (in) 12,7 (1/2 ) 15,9 (5/8 ) Drain piping mm 25 Operating ambient temp. range C Cooling +17...+32 / Heating +10...+28 Operating conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 8 m 0 m Heating mode 20 C DB, 15 C WB 7 C 8 m 0 m The sound pressure value may vary depending on ambient conditions.

38 VRF Cassette 2way indoor units Cassette 2Way Indoor Unit SYSVRF 2W Features Stylish look with new decorative panel. Slim casing for easy installation in narrow ceiling. Integrated drain pump with a head of 750mm. Built-in electronic expansion valve (EXV) ensuring precise flow control. Infrared receiver and remote controller SYS RM 02. With address setting function as standard equipment. Power supply 50Hz. Accessories/option Wired controller SYS WC 29 with address setting function for heat pump system. Wired controller SYS WC 120 for heat recovery system. Infrared remote control SYS RM 02 (standard) Wired controller SYS WC 120 Art. no. 314774 (optional) Wired controller SYS WC 29 Art. no. 314772 (optional) Dimensions Fresh air connector 257 Φ 32 57 1172 701 129 129 44 51 591 436 241 185 120 104 44 91 Φ160 Φ125 117 45 151 192 299 299 176 171 91 Φ 32 1430 42~45 680 The ceiling opening (1390*0) 20 20 The panel contour dimension 1430 The ceiling opening dimension 1390 Hanging screw bolts distance 1207 Machine body size 1172 20 The panel contour dimension 680 The ceiling opening dimension 0 20 Machine body size 591 Hanging screw bolts distance 520 701 129 44 151

VRF Cassette 2way indoor units 39 Technical features Model Indoor unit Model Panel unit SYSVRF SYSPANEL 2W 22 Q 2W VRF 2W 28 Q 2W VRF 2W 36 Q 2W VRF 2W 45 Q 2W VRF 2W 56 Q 2W VRF Art. no. Indoor unit 314218 314219 314220 314221 314222 Art. no. Panel unit 314224 Power Supply V/Ph/Hz 220-240/1/50 Cooling capacity kw 2,2 2,8 3,6 4,5 5,6 Power Input W 57 60 92 108 Current A 0,35 0,45 0,55 Heating capacity kw 2,6 3,2 4,0 5,0 6,3 Power Input W 57 60 92 108 Current A 0,35 0,45 0,55 Indoor fan motor AC motor Air flow (H/M/L) m 3 /h 654/530/410 725/591/458 850/670/550 980/800/670 Sound pressure level (H/M/L) db(a) 33/29/24 36/32/29 39/35/30 Unit Panel Refrigerant Piping dimension Dimension (LxWxH) mm 1.172 591 299 Packing (LxWxH) mm 1.355 675 400 Net/gross weight kg 34/42,5 36/44,5 Dimension (LxWxH) mm 1.430x680x53 Packing (LxWxH) mm 1.525x765x130 Net/gross weight kg 10,5/15 R410A Liquid pipe mm (in) 6,4 (1/4 ) 9,5 (3/8 ) Gas pipe mm (in) 12,7 (1/2 ) 15,9 (5/8 ) Drain piping mm 32 Operating ambient temp. range C Cooling +17...+32 / Heating +10...+28 Operating conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 8 m 0 m Heating mode 20 C DB, 15 C WB 7 C 8 m 0 m The sound pressure value may vary depending on ambient conditions.

40 VRF Ceiling/Floor indoor units Ceiling and Floor Indoor Units SYSVRF CEILING Features Flexible vertical or horizontal installation, even into a corner of the ceiling. Even and smooth air distribution due to auto horizontal and auto vertical swing function. Models 90,112 and 140 equipped with high efficient DC fan motor. Wide angle air flow. Low noise operation. Washable air filter, easy for insertion and removal. Built-in electronic expansion valve (EXV) ensuring precise flow control. Infrared receiver and remote SYS RM 02 with address setting function as standard equipment. Power supply 50Hz or 60Hz (only 90, 112 and 140). Accessories/option Wired controller SYS WC 29 with address setting function for heat pump system. Wired controller SYS WC 120 for heat Dimensions SYSVRF CEILING 36/45/56/71 Q recovery system. SYSVRF CEILING 112/140 Q Infrared remote control SYS RM 02 (standard) Wired controller SYS WC 29 Art. no. 314772 (optional) Wired controller SYS WC 120 Art. no. 314774 (optional) 995 906,5 401 371 35 39,5 198,2 1670 1542,3 724,5 630,5 235 112,5 69,5 200 655 675 207 98 133,5 175 144 184,5 255,2 SYSVRF CEILING 90 Q 1284,5 1194,5 547 515 39,5 37 198,2 200 655 98 133,5 175 1670 1542,3 724,5 630,5

VRF Ceiling/Floor indoor units 41 Technical features Model Indoor unit SYSVRF CEILING 36 Q CEILING 45 Q CEILING 56 Q CEILING 71 Q CEILING 90 Q CEILING 112 Q CEILING 140 Q Art. no. 314116 314117 314118 314119 314282 314283 314284 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 or 60 Cooling capacity kw 3,6 4,5 5,6 7,1 9,0 11,2 14,0 Power Input W 49 120 122 125 126 65x2 Current A 0,55 0,57 0,60 0,83 Heating capacity kw 4,0 5,0 6,3 8,0 10,0 12,5 15,5 Power Input W 49 120 122 125 126 65x2 Current A 0,55 0,57 0,60 0,83 Indoor fan motor AC motor DC motor Air flow (H/M/L) m 3 /h 650/ 570/500 800/600/500 1.200/ 900/700 1.980/1.860/1.730 Sound pressure level (H/M/L) db(a) 40/38/36 43/41/38 45/43/40 47/45/42 Dimension (LxWxH) mm 990x206x660 Packing (LxWxH) mm 1.089x296x744 1.280x 206x660 1.379x 296x744 1.670x244x680 1.7x329x760 Net/gross weight kg 26/32 28/34 34,5/41 54/59 Refrigerant Piping dimension R410A Liquid pipe mm (in) 6,4 (1/4 ) 9,5 (3/8 ) Gas pipe mm (in) 12,7 (1/2 ) 15,9 (5/8 ) Drain piping mm 16 Operating ambient temp. range C Cooling +17...+32 / Heating +10...+28 Operating conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 8 m 0 m Heating mode 20 C DB, 15 C WB 7 C 8 m 0 m The sound pressure value may vary depending on ambient conditions.

42 VRF Duct indoor units I Medium Static Pressure Duct Indoor Units SYSVRF DUCT Features External static pressure up to 100 Pa. All models are equipped with high efficient DC fan motor. Washable air filter placed in an aluminum frame which is removable downward from the bottom. Fresh air hole, air inlet/outlet flange are standard for easy duct connection. Air inlet from back as standard and from bottom as optional with the same flange plate. Integrated drain pump with a head of 750 mm. Electronic expansion valve (EXV) fixed inside of the indoor unit. Std functional port such as remote on/off free contact. Display board with infrared receiver as standard equipment. Unit available with wired controller SYS WC 29 or with infrared controller SYS RM 02 Power supply 50Hz or 60Hz. Wired controller SYS WC 29 (standard) Wired controller SYS WC 120 Art. no. 314774 (optional) Infrared remote control SYS RM 02 (standard) Accessories/option Wired controller SYS WC 120 for heat recovery system. Dimensions Indoor unit SYSVRF DUCT 15/22 Q DUCT 28 Q DUCT 36 Q DUCT 45 Q DUCT 56 Q A mm 700 700 700 920 920 H B mm 210 210 210 210 210 C mm 500 500 500 500 500 B D mm 450 450 450 450 450 E mm 780 780 780 1.000 1.000 F mm 45 45 45 45 45 F G G mm 512 512 512 732 732 A E H mm 17 17 17 17 17 Indoor unit SYSVRF DUCT 71 Q DUCT 90 Q DUCT 112 Q DUCT 140 Q A mm 1.140 1.140 1.140 1.200 B mm 210 270 270 300 C mm 500 775 775 865 D mm 450 710 710 800 D C E mm 1.220 1.230 1.230 1.290 F mm 45 65 65 80 G mm 732 933 933 969 H mm 17 35 35 40

VRF Duct indoor units 43 Technical features Model Indoor unit SYSVRF DUCT 15 Q DUCT 22 Q DUCT 28 Q Art. no. with SYS WC 29 314784 314761 314762 314763 3147 314765 314766 314261 314262 314258 Art. no. with SYS RM 02 314846 314847 314848 314849 314850 314851 314852 314853 314854 314855 DUCT 36 Q DUCT 45 Q DUCT 56 Q Power Supply V/Ph/Hz 220-240/1/50 or 60 Cooling capacity kw 1,5 2,2 2,8 3,6 4,5 5,6 7,1 9,0 11,2 14,0 Power Input W 39 39 39 45 58 89-108 178 204 Current A 0,31 0,31 0,31 0,33 0,36 0,36 0,47 1,0 1,8 1,55 Heating capacity kw 1,7 2,6 3,2 4,0 5,0 6,3 8,0 10,0 12,5 15,5 Power Input W 39 39 39 45 58 89-108 178 204 Current A 0,31 0,31 0,31 0,33 0,36 0,36 0,47 1,0 1,8 1,55 Indoor fan motor Air flow (H/M/L) m 3 /h 460/ 420/360 460/ 420/360 460/ 420/360 540/ 469/480 740/ 0/550 DC motor 860/ 760/630 DUCT 71 Q 1.100/ 940/790 Sound pressure level (H/M/L) db(a) 35/33/31 35/34/31 36/34/31 37/36/33 38/37/33 38/37/33 40/38/34 44/38/37 47/41/37 47/42/38 DUCT 90 Q 1.400/ 1.050/ 880 External static pressure Rated/Range Pa 10 / 0-50 20 / 0-100 Dimension (LxHxW) mm 780x210x500 1.000x210x500 Packing (LxHxW) mm 870 285 525 1.115x285x525 DUCT 112 Q 1.800/ 1.600/ 1.400 DUCT 140 Q 2.250/ 1.900/ 1.460 40 / 25-150 1.220x 210x500 1.230 270 775 1.290 300 865 1.335x 285x525 1.355 350 795 1.400 375 925 Net/gross weight kg 17,5 / 20,5 23/26 28/32 40/48 49/58 Refrigerant Piping dimension R410A Liquid pipe mm (in) 6,4 (1/4 ) 9,5 (3/8 ) Gas pipe mm (in) 12,7 (1/2 ) 15,9 (5/8 ) Drain piping mm OD 25 Operating ambient temp. range C Cooling +17 +32 / Heating +10 +28 Operating conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 8 m 0 m Heating mode 20 C DB, 15 C WB 7 C 8 m 0 m The sound pressure value may vary depending on ambient conditions.

44 VRF Duct HP indoor units High Static Pressure Duct Indoor Units SYSVRF DUCT HP Features External static pressure up to 200 Pa. Washable air filter placed in an aluminum frame which is removable downward from the bottom. Easy access both in rear and bottom. Fresh air hole, air inlet/outlet flange are standard for easy duct connection. All models are equipped with high efficient DC fan motor Electronic expansion valve (EXV) fixed inside of the indoor unit (not for model 200 and 280). Display board with infrared receiver as standard equipment. Wired controller SYS WC 90 with address setting function as standard equipment. Power supply 50Hz or 60Hz. Accessories/option Infrared remote SYS RM 02 with address setting function for heat pump system. Wired controller SYS WC 120 for heat recovery system. Wired controller SYS WC 90 (standard) Wired controller SYS WC 120 Art. no. 314774 (optional) Infrared remote control SYS RM 02 Art. no. 314138 (optional) Dimensions SYSVRF DUCT HP 71/112 Q SYSVRF DUCT HP 140 Q Plastic cover 420 85 214 952 856 86 Electrical control box Plastic cover 82 68 135 930 88 249 29 82 24 46 56 270 420 Electrical control box SYSVRF DUCT HP 200/280 Q 1121 75 936 200 50 343 378 60 96

VRF Duct HP indoor units 45 Technical features Model Indoor unit SYSVRF DUCT HP 71 Q DUCT HP 112 Q DUCT HP 140 Q DUCT HP 200 Q DUCT HP 280 Q Art. no. 314560 314561 314562 314563 3145 Power Supply V/Ph/Hz 220-240/1/50 or 60 Cooling capacity kw 7,1 11,2 14,0 20,0 28,0 Power Input W 180 380 420 800 800 Current A 1,4 2,9 4,5 6,0 6,0 Heating capacity kw 8,0 12,5 16,0 22,5 31,5 Power Input W 180 380 420 800 800 Current A 1,4 2,9 4,5 6,0 6,0 Indoor fan motor Air flow (H/M/L) m 3 /h 1.500/ 1.390/1.250 2.080/ 1.930/1.710 DC fan motor 2.860/ 2.440/2.010 4.820/ 4.660/4.620 4.870/ 4.760/4.690 Sound pressure level (H/M/L) db(a) 46/41/42 50/47/45 53/50/48 57/53/50 57/53/50 External static pressure Rated/Range Pa 25 / 0~196 37 / 0~196 50 / 0~196 62 / 40~200 62 / 40~200 Dimension (LxWxH) mm 856x690x420 856x690x420 1.200x600x400 1.356x763x470 1.356x763x470 Packing (LxWxH) mm 1.090x768x440 1.090x768x440 1.436x768x450 1.509x9x570 1.509x9x570 Net/gross weight kg 41/47 47/53 68/70 108/120 108/120 Refrigerant Piping dimension R410A Liquid pipe mm (in) 9,5 (3/8 ) 9,5 (3/8 ) 9,5 (3/8 ) 9,5 (3/8 ) (x2) 9,5 (3/8 ) (x2) Gas pipe mm (in) 15,9 (5/8 ) 15,9 (5/8 ) 15,9 (5/8 ) 15,9 (5/8 ) (x2) 15,9 (5/8 ) (x2) Drain piping mm 32 32 32 32 32 Operating ambient temp. range C Cooling +17 +32 / Heating +10 +28 Fan performance SYSVRF DUCT HP 71 Q SYSVRF DUCT HP 112 Q SYSVRF DUCT HP 140 Q SYSVRF DUCT HP 200 Q SYSVRF DUCT HP 280 Q Operating conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 8 m 0 m Heating mode 20 C DB, 15 C WB 7 C DB 8 m 0 m The sound pressure value may vary depending on ambient conditions.

46 Exposed floor indoor unit Exposed floor indoor unit SYSVRF FLOOR EB Features With 22cm of depth and 67cm of height, the unit perfectly fits any interior design. Models 71 and 80 are equipped with high efficient DC fan motor. Washable air filter included. Built-in electronic expansion valve (EXV) ensuring precise flow control. Infrared receiver and remote controller SYS RM 02 with address setting function as standard equipment. Power supply 50Hz or 60Hz (only 71 and 80). Accessories/option Wired controller SYS WC 29 with address setting function for heat pump system. Wired controller SYS WC 120 for heat recovery system. Infrared remote control SYS RM 02 (standard) Wired controller SYS WC 120 Art. no. 314774 (optional) Wired controller SYS WC 29 Art. no. 314772 (optional) Dimensions A B Mounting hole, 4 I C D EXV Gas side connector Liquid side connector 4xФ11 4xФ18 H F G E J Air inlet grille Indoor unit SYSVRF FLOOR EB 22 Q FLOOR EB 28 Q FLOOR EB 36 Q FLOOR EB 45 Q FLOOR EB 56 Q FLOOR EB 71 Q FLOOR EB 80 Q A mm 1.000 1.200 1.500 B mm 725 925 1.225 C mm 672 D mm 592 E mm 284 310 F mm 232 258 G mm 345 H mm 94 100 100 I mm 220 J mm 150

Exposed floor indoor unit 47 Technical features Model Indoor unit SYSVRF FLOOR EB 22 Q FLOOR EB 28 Q FLOOR EB 36 Q FLOOR EB 45 Q FLOOR EB 56 Q FLOOR EB 71 Q FLOOR EB 80 Q Art. no. 314225 314226 314227 314228 314229 314285 314286 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 or 60 Cooling capacity kw 2,2 2,8 3,6 4,5 5,6 7,1 8,0 Power Input W 40 46 49 88 130 Current A 0,18 0,21 0,22 0,22 0,4 0,56 0,59 Heating capacity kw 2,6 3,2 4,0 5,0 6,3 8,0 9,0 Power Input W 40 46 49 88 130 Current A 0,18 0,21 0,22 0,22 0,4 0,56 0,59 Indoor fan motor AC fan motor DC fan motor Air flow (H/M/L) m 3 /h 530/ 456/400 569/ 485/421 624/ 522/375 660/ 542/440 1.150/ 970/830 1.380/1.100/870 Sound pressure level (H/M/L) db(a) 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 Dimension (LxWxH) mm 1.000 625 220 Packing (LxWxH) mm 1.182 683 312 1.200 625 220 1.382 683 312 1.200 625 220 1.382 683 312 1.500 625 220 1.682 683 312 1.500 625 220 1.682 683 312 Net/gross weight kg 30/38 35,5/41 35,5/41 42/51 42/51 44/53 Refrigerant Piping dimension R410A Liquid pipe mm (in) 6,35 (1/4 ) 9,5 (3/8 ) Gas pipe mm (in) 12,7 (1/2 ) 15,9 (5/8 ) Drain piping mm 16 Operating ambient temp. range C Cooling +17 +32 / Heating +10 +28 Operating conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 8 m 0 m Heating mode 20 C DB, 15 C WB 7 C DB 8 m 0 m The sound pressure value may vary depending on ambient conditions.

48 Concealed floor indoor unit Concealed floor indoor unit SYSVRF FLOOR CB Features With only 21cm thick, the unit can be easily hidden in narrow space. Models 71 and 80 are equipped with high efficient DC fan motor. Washable air filter included. Built-in electronic expansion valve (EXV) ensuring precise flow control. Infrared receiver and remote controller SYS RM 02 with address setting function as standard equipment. Power supply 50Hz or 60Hz (only 71 and 80). Accessories/option Wired controller SYS WC 29 with address setting function for heat pump system. Wired controller SYS WC 120 for heat recovery system. Infrared remote control SYS RM 02 (standard) Wired controller SYS WC 120 Art. no. 314774 (optional) Wired controller SYS WC 29 Art. no. 314772 (optional) Dimensions Connecting point of refrigerant pipe (Liquid side ΦA) Connecting point of refrigerant pipe 345 544 177 (Gas side ΦB) C 212 MODEL A B C FLOOR CB 22 mm 6,4 12,7 725 FLOOR CB 28 mm 6,4 12,7 725 FLOOR CB 36 mm 6,4 12,7 925 FLOOR CB 45 mm 6,4 12,7 925 FLOOR CB 56 mm 9,5 15,9 1.225

Concealed floor indoor unit 49 Technical features Model Indoor unit SYSVRF FLOOR CB 22 Q FLOOR CB 28 Q FLOOR CB 36 Q FLOOR CB 45 Q FLOOR CB 56 Q FLOOR CB 71 Q FLOOR CB 80 Q Art. no. 314232 314233 314234 314235 314236 314287 314288 Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 or 60 Cooling capacity kw 2,2 2,8 3,6 4,5 5,6 7,1 8,0 Power Input W 40 46 49 88 130 Current A 0,18 0,21 0,22 0,22 0,4 0,56 0,59 Heating capacity kw 2,6 3,2 4,0 5,0 6,3 8,0 9,0 Power Input W 40 46 49 88 130 Current A 0,18 0,21 0,22 0,22 0,4 0,56 0,59 Indoor fan motor AC fan motor DC fan motor Air flow (H/M/L) m 3 /h 530/ 456/400 569/ 485/421 624/ 522/375 660/ 542/440 1.150/ 970/830 1.380/1.100/870 Sound pressure level (H/M/L) db(a) 36/33/29 37/34/30 37/34/30 41/35/31 44/39/33 External static pressure Pa 12 Dimension (LxWxH) mm 840 544 212 Packing (LxWxH) mm 939 639 305 1.036 544 212 1.139 639 305 1.036 544 212 1.139 639 305 1.336 544 212 1.425 639 305 1.336 544 212 1.425 639 305 Net/gross weight kg 25/27 29,5/34 29,5/34 33/39 33/39 36/40 Refrigerant Piping dimension R410A Liquid pipe mm (in) 6,35 (1/4 ) 9,53 (3/8 ) Gas pipe mm (in) 12,7 (1/2 ) 15,9 (5/8 ) Drain piping mm 16 Operating ambient temp. range C Cooling +17 +32 / Heating +10 +28 Operating conditions Indoor unit Outdoor unit Piping lenght Level difference Cooling mode 27 C DB, 19 C WB 35 C DB 8 m 0 m Heating mode 20 C DB, 15 C WB 7 C DB 8 m 0 m The sound pressure value may vary depending on ambient conditions.

50 VRF Heat Recovery Ventilation Heat Recovery Ventilation Units SYSVRF HRV Features Cross flow heat exchanger made of special paper for enhanced heat exchange efficiency. Main structure made of galvanized steel sheet. High efficient DC fan motor assures low power consumption. 3 fan speeds available. Temperature exchange efficiency above 75%. Compact design and flexible installation in the false ceiling. Different operating modes available: heat exchange, bypass, auto, exhaust/supply mode (bypass damper not included in the HRV 2000 Q). Insulation material guarantees quiet operation and thermal insulation. Thanks to the flexible control the HRV unit can be interlocked to the operation of the VRF indoor units. Wired controller SYS WC 27 as standard equipment. Can be connected to centralized controller SYS CWC30, SYS CWC09. Power supply 50Hz or 60Hz. SYSVRF HRV 500/1000 Q SYSVRF HRV 2000 Q Wired controller SYS WC 27 (standard) Dimensions SYSVRF HRV 500/1000 Q SYSVRF HRV 2000 Q N L Door Wire control box N2 H W 75 1550 C W2 Door Wire control box Air exhaust vent By-pass system Air return vent W1 1400 Fresh air inlet Air supply vent L1 G 540 Model SYSVRF HRV 500 Q SYSVRF HRV 1000 Q L 824 1.116 700 L1 754 1.045 W 904 1.134 250 1600 W1 960 1.190 W2 500 678 H 270 388 C 107 85 G 19 19 Air exhaust vent Fresh air inlet 20 50 Air supply vent 1370 Air return vent 50 N Φ194 Φ242 N2 111 170 1650

VRF Heat Recovery Ventilation 51 Technical features Model Indoor unit SYSVRF HRV 500 Q HRV 1000 Q HRV 2000 Q Art. no. 314289 314290 314291 Power supply V/Ph/Hz 220-240/1/50 or 60 Indoor Fan motor DC fan motor Nominal air flow (H) m 3 /h 500 1.000 2.000 External static pressure (H) Pa 80 100 170 Power input W 170 360 1.340 Enthalpy exchange efficiency/ Cooling / Heating Temperature exchange efficiency Cooling / Heating % 78,2/80,4 76,9/78,6 78,7/80,3 % 76,1/76,1 75,8/75,8 77,2/77,2 Sound pressure level (H) db(a) 35 40 53 Dimensions (LxWxH) mm 1.020x1.036x270 1.276x1.269x388 1.650x1.470x540 Packing (LxWxH) mm 1.120x1.120x452 1.390x1.350x570 1.760x1.580x720 Net/gross weight kg 35/60 69/100 165/247 Duct connection dimensions mm 194 242 346x326 Ambient condition C -7 +43/ max 80% RH Fan performance SYSVRF HRV 500 Q Air flow (m 3 /h) 675 650 625 600 575 550 525 500 20 40 60 80 100 120 150 170 External static pressure (Pa) SYSVRF HRV 1000 Q Air flow (m 3 /h) 1300 1250 1200 1150 1100 1050 1000 950 20 40 60 80 100 120 150 170 External static pressure (Pa) SYSVRF HRV 2000 Q Air flow (m 3 /h) 3050 2900 2750 2600 2450 2300 2150 2000 20 40 60 80 100 120 150 170 External static pressure (Pa) Multi-modes for different applications Heat exchange mode When air flow formed by the fans goes through the heat exchanged core in cross way, due to temperature difference between two channels of the core, thermal transmission happens naturally. In summer days, high temperature outdoor air gets cooled by indoor exhaust air; in winter, low temperature outdoor air gets heated by indoor exhaust air. So the energy contained in exhaust air can be reclaimed and energy efficiency gets improved. Heat exchange mode EA OA EA=Exhaust air OA=Outdoor air Element Damper RA EA SA OA Bypass mode RA=Return air SA=Supply air Element Damper RA SA Bypass mode In mild climate areas or seasons, when temperature and humidity level difference between indoor and outdoor is small, the unit works as conventional ventilation fan. Both supply fan and exhaust fan works at the same speed (Hi/ mid/low/auto). Air supply mode It is one kind of bypass mode with air supply fan speed higher than exhaust fan speed. It can be used in mild climate area where large amount fresh air is needed. Operating conditions Exhaust air mode It is also one kind of bypass mode with exhaust fan speed higher than air supply fan speed. It can be used in mild climate area where large amount exhaust air needs to be expelled. Auto mode The controller chooses heat exchange mode or bypass mode according to the temperature difference between outdoor and indoor temperature. Both the two fans work at low speed. Exhaust air Fresh air Cooling mode 27 C DB, 19,5 C WB 35 C DB, 28 C WB Heating mode 21 C DB, 13 C WB 5 C DB, 2 C WB The sound pressure value may vary depending on ambient conditions.

52 VRF connection to AHU Connection to DX coil SYSVRF AHU Features The SYSVRF AHU 5HP, 10HP and 20HP can be used to connect the SYSVRF outdoor units to an external DX coil with capacity from 9 kw to 56 kw. Nominal capacity in cooling 14kW (5HP), 28kW (10HP) and 56kW (20HP). Modulating cooling/heating capacity thanks to the built-in Electronic Expansion Valve (EXV) controlled by the superheat degree of the DX coil. The SYSVRFAHU kit includes four temperature sensors, one for the air intake of the AHU and three for a precise monitoring of the DX evaporator coil. With the 2 nd generation it is possible to connect in pararrel up to 4 AHU boxes with Master-Slave configuration thus reaching a total capacity of 224kW in a single refrigerant circuit. For indoor installation in vertical position. Wired controller SYS WC 29 (standard) Infrared remote control SYS RM 02 Art. no. 314138 (optional) Failure alarm codes on the PCB for quick service checking. Environment friendly R410A refrigerant. Connection to Systemair network monitoring system. Wired controllor SYS WC 29 as standard equipment. Power supply 50Hz or 60Hz. Connection diagram SYSVRF indoor units max 8 m SYSVRF outdoor unit max 175 m SYSVRF AHU FRICO Air Curtain SYSVRF AHU Technical features max 8 m SYSTEMAIR Air Handling Unit Model AHU box (1 st generation) Model AHU box (2 nd generation) SYSVRF AHU 5HP SYSVRF AHU 10HP SYSVRF AHU 20HP SYSVRF AHU 5HP S SYSVRF AHU 10HP S SYSVRF AHU 20HP S Art. no. (1st generation) 314188 314189 314190 Art. no. (2nd generation) 313395 313396 313397 Power supply V/Ph/Hz 220-240/1/50, 208-230/1/60 DX coil capacity kw 9-20 20-36 36-56 Air volume m 3 /h 1.400-2.700 3.000-4.500 5.400-7.500 Dimensions (LxWxH) mm 375x350x150 Packing (LxWxH) mm 490x240x420 Piping diameters in/out mm 8/8 12,7/12,7 '16/16 IP-class IP X0 IP X0 IP X0 Air return temperature range C Cooling +17 +43 / Heating -5 +30 / 80% / humidity

VRF connection to AHU SYSVRF selection and designing software Selection and designing software for all SYSVRF systems, 2-pipe, 3-pipe and Mini-VRF. Main tasks: Calculation of the heat loads and selection of the necessary cooling /heating capacity, type and location of outdoor and indoor units. Calculation of the refrigerant piping diameters and the required additional amount of refrigerant. Selection of an optimal set of piping joints. Building Management System. Correction of the performance of indoor units. Automatic check of the circuit for compliance requirements and limits on the maximum length of refrigerant pipelines and indoor-outdoor elevations. Conclusion of project documentation - specification (Excel), a detailed specification with the drawings (Word), and print out of all documents. Selection of the DX-coil connected to the SYSVRF AHU box. 53

54 VRF control systems Control systems Remote control for indoor units Infrared remote controller SYS RM 02, Art. no. 314138 Turn On/Off Setting mode Cool/Heat/Auto/Dry/Fan Temperature setting Fan speed selection High/Medium/Low/Auto Air swing function 24h On/Off timer Economy mode Turbo function Turn on/off the LCD backlight Setting the address of indoor units Wired controller with touch-key buttons SYS WC 29 (for 2-pipe systems), Art. no. 314772 Wired controller with touch-key buttons SYS WC 120 (for 3-pipe systems), Art. no. 314774 Main functions: Turn On/Off Setting mode Cool/Heat/Auto/Dry/Fan Temperature setting Fan speed selection High/Medium/Low/Auto Air swing function 24h On/Off timer Silent mode operation Locking the controller s buttons Indication of air filter cleaning Follow me function (SYS WC29 only) IR signal receiver for the infrared remote controller (SYS WC 29 only) Setting the address of indoor units (SYS WC 29 only) 2-ways communication (SYS WC 120 only) Group controller for indoor units SYS WC 150, Art. no. 314787 The group controller allows to control up to 16 indoor units from a single local controller. It can be matched to: Infrared remote controller SYS RM 02, Art. no. 314138 Wired controlled SYS WC 29, Art. no. 314772

VRF control systems 55 Centralized controller with touch-key buttons SYS CWC 30, Art. no. 314773 The centralized remote controller is intended to control a group of indoor units (up to indoor units). Main functions: Turn On/Off Setting mode Cool/Heat/Auto/Dry/Fan Temperature setting Fan speed selection High/Medium/Low/Auto Air swing function 24h On/Off timer Silent mode operation Locking the controller buttons Indication of air filter cleaning Turn on/off the LCD backlight The centralized controller allows to set all operating parameters for each indoor unit separately or for a group of indoor units at the same time. It provides the ability to connect to a PC via a converter RS485/RS232. Centralized controller with weekly timer SYS CWC 09, Art. no. 314141 The centralized remote controller is intended to control a group of indoor units (up to indoor units). It performs the same functions of the centralized controller SYS CWC 30, with the possibility of drawing up management programs for the week with up to 4 different modes per day. It doesn t have the R485 port for the connection to a PC. Central controller for outdoor units SYS CWC 02, Art. no. 314142 Remote control designed to monitor the SYSVRF outdoor units (max. 32 outdoor units / 8 systems). This controller greatly simplifies the maintenance of the SYSVRF installation, since it has an error indicator and allows the technician to check the operating status of all major components of the system, monitor temperature, fan speed, operation of electronic expansion devices, operation of compressors, etc... If the outdoor unit is equipped with a power meter, the controller performs an accounting function of the consumed electricity. SYS CWC 02 can communicate with a PC through a RS485/RS232 converter and one PC can connect up to 16 outdoor controllers SYS CWC 02. Data Converter SYS CWC 15, Art. no. 314263 Provides the ability to manage the indoor units from a PC, tablet or smartphone (with Android OS) and other intelligent terminals (up to indoor units). Provides data conversion between the protocols TCP/IP and RS485. Provides a TCP / IP port for accessing WEB/HTTP/TCP/IP. Built-in web server allows you to organize access through the cloud service. The user receives access to the SYSVRF system management through LAN and WAN. The user can check and set the following functions: On/Off, setting temperature, operating mode and fan speed. Allows individual and group control, indicates the status of each indoor unit, setting weekly timer, lock the operating parameters and the remote controller, provides the list of error codes.

56 VRF control systems Central management IMS (Intelligent Manager of Systemair) The system provides full control of the SYSVRF system, as well as monitoring of all relevant operating parameters. It can manage up to 1024 indoor units and up to 256 outdoor units. The main elements of a centralized control system: Interface unit (gateway) SYS M-INTERFACE, Art. no. 313735. The system allows the connection of up to 4 interface blocks. A gateway is designed to operate with 256 indoor units and outdoor units. Software IMS software, Art. no. 313734. The remote control of the SYSVRF installation can be performed from a PC, tablet, mobile phone and other intelligent terminals. The module is compatible with complex building management systems (BMS). Router connection interface units and communication networks (not supplied by SYSTEMAIR). Main functions: Individual control with system blocks: switching modes, setting temperatures, lock local controllers. User can set limits to any parameter of indoor unit, such as cooling/heating temperature set-point, fan speed, operating mode, etc Simple schedule control, automatically performs facility start/stop control, switches the operating mode, sets temperatures and enabling/disabling the remote control according to the present time schedule. Electricity charge apportionment can be performed easily for the power consumed, when billing users for air conditioning power charges, such as tenants in a commercial building, offices in a rental building, or rooms in a hotel. Automatic backup web-gateway to SD-card in the event of failures of the power supply or system fault. Storing data on a hard disk in the last three months. Indication of filter cleaning. Fault and reported them to mobile communications. Emergency stop function and connection to external signals through contacts. Maximum: 1024 indoor units; 256 outdoor units; independent refrigerant circuits.

VRF control systems 57 Connection to an integrated building management system (BMS) SYSVRF systems can be integrated into a comprehensive building management system (BMS) using all most popular protocol: Bacnet, Modbus, LonWorks and KNX. Gateway SYS CWC 08 (Bacnet Protocol), Art. no. 314145 One gateway SYS CWC 08 can connect up to four central controller (SYS CWC 30 or SYS CWC 02). Each group can contain a maximum of indoor units or 32 outdoor units. Bacnet RM 02 WC 29/120 Bacnet BMS CWC 30 Мax. CWC 08 CWC 30 Мax. CWC 30 Мax. Power digital meter Мax. 32 CWC C 02 Gateway SYS CWC 18 (Modbus protocol), Art. no. 314382 One gateway SYS CWC 18 can connect directly up to indoor units or 4 outdoor units. Modbus Modbus BMS RM 02 WC 29/120 Мax. CWC 18 Мax. 4 Gateway SYS CWC (Lonworks protocol), Art. no. 314144 One gateway SYS CWC can connect directly up to indoor units. LonWorks Lonwork BMS RM 02 WC 29/120 CWC Мax. Gateway SYS CWC 01 (KNX protocol), Art. no. 314788 The gateway SYS CWC 01 should be connected directly to a single indoor unit.

58 Controller table VRF Controller matching table - VRF units Infrared controller SYS RM 02 Wired controller SYS WC 29 (1way communic.) Wired controller SYS WC 120 (2ways communic.) Wired controller SYS WC 27 (1way communic.) Remote On/Off Art. no. 314138 314772 314774 314856 standard in the PCB Picture MINI l -- l l -- l DUCT l -- l CEILING l -- l WALL l -- l DUCT HP l -- l 1W l -- l 2W l -- l FLOOR EB l -- l FLOOR CB l -- l HRV -- -- l -- AHU box (1 st generation) l -- l AHU box (2 nd generation) l -- l l= included in the unit; = optional part; - = not available.

Controller table VRF 59 Alarm contact Group control SYS WC 150 Central controller SYS CWC 30 Central controller SYS CWC 09 standard in the PCB 314787 314773 314141 BMS gateway SYS CWC 18, SYS CWC, SYS CWC 08, SYS CWC 01 314382, 314144, 314145, 314788 Data Converter SYS CWC 15 Intelligent Manager of Systemair IMS + SYS M-INTER- FACE 314263 313734 + 313735 l l l l l l l l l l -- -- l l only with SIEMENS controller only with SYSTEMAIR controller only with SYSTEMAIR controller only with SYSTEMAIR controller only with SYSTEMAIR controller only with SYSTEMAIR controller only with SYSTEMAIR controller

60 VRF piping joint Piping joints for 2-pipe refrigerant system Outdoor unit Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use OUT 02 HP 314146 255x150x185 1,5 Connect two outdoor units of SYSVRF AIR EVO HP R series OUT 03 HP 314147 345x160x285 3,4 Connect three outdoor units of SYSVRF AIR EVO HP R series OUT 04 HP 314148 475x165x300 4,8 Connect four outdoor units of SYSVRF AIR EVO HP R series Indoor unit Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use IN 01 2P 314149 290x105x100 0,4 Capacity of connected indoor units < 23 kw IN 02 2P 314150 290x105x100 0,6 Capacity of connected indoor units 23-33 kw IN 03 2P 314151 310x130x125 0,9 Capacity of connected indoor units 33-92 kw IN 04 2P 314152 350x180x170 1,5 Capacity of connected indoor units 92-135 kw IN 05 2P 314153 365x195x215 1,9 Capacity of connected indoor units > 135 kw IN 06 2P 314154 390x230x255 3,1 Capacity of connected indoor units 185 kw and long piping Piping joints for 3-pipe refrigerant system Outdoor unit Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use OUT 02 HR 314155 272 167 232 2,2 Connect two outdoor units of SYSVRF AIR EVO HR R series OUT 03 HR 314156 472 157 312 5,0 Connect three outdoor units of SYSVRF AIR EVO HR R series OUT 04 HR 314184 745 160 335 7,5 Connect four outdoor units of SYSVRF AIR EVO HR R series Indoor unit Model Art. no. Packing LxWxH (mm) Gross weight (kg) Use IN 01 3P 314157 257 127 107 0,8 Capacity of connected indoor units < 16,6kW IN 02 3P 314158 287 137 107 0,9 Capacity of connected indoor units 16,6-33kW IN 03 3P 314159 297 167 177 1,4 Capacity of connected indoor units 33-66kW IN 04 3P 314160 372 197 187 2,3 Capacity of connected indoor units 66-92kW IN 05 3P 314185 432 222 227 3,3 Capacity of connected indoor units > 92kW