Protec. Protec Algo-Tec TM 6400 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Similar documents
Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Protec Algo-Tec Protec Algo-Tec 6400 ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE FIRE CONTROL SYSTEM. Protec Fire Detection plc

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections.

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

Algo-Tec 6500/6600 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

The supplier and installer of the system should be approved by the local civil defence authority.

ZXSe Range Data Sheet

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

HERCULES 6 GRAPHICS SYSTEM

PROPOINTPLUS ASPIRATING SMOKE DETECTION SYSTEM

System 800 Addressable Fire Detection & Alarm System

Intelligent Security & Fire Ltd

Excel-EN Conventional Fire Control Panel

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

Intelligent Security & Fire Ltd

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Advanced FireAlarm Panel 1-4Loop

user manual Document No , Revision 03 November 2015

Solution F2. Fire Alarm Control Panels one step ahead.

HART XL High Sensitivity Smoke Detection

Installation, Operating and Maintenance Manual

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

Xenex Conventional Fire Detection & Alarm System

MINERVA MZX125 Digital Addressable Fire Detection System

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

intelligent fire alarm ID60series panels

The EN54 Part 2, 4 and 13 Fire System

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

Conventional Fire Detection

Operating instructions Vigilon panel and Network node Fire detection and alarm system

Intelligent addressable fire alarm control panel

ID50series. intelligent fire alarm panels

ID3000 intelligent. fire alarm panel

ID3000 intelligent. fire alarm panel

Saxon Range 1-8 Zone Convertional Control Panels

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

HART XL High Sensitivity Smoke Detection

CIRRUS PRO. User Manual and Responsibilities ASPIRATING FIRE DETECTOR

Product Catalogue. Intelligent Control Equipment for Life Safety. Issue 1

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Written by: A.C. Amended by G.G. Checked by: JBJ/PB Approved by:jbj

MINERVA MZX125. Digital Addressable Fire Detection System

DS7400Xi Addressable Control/ Communicator

Product Data Sheet. Remote Terminals. Features:

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Document No Issue 4 user manual

Vigilant MX4428 Fire Alarm System

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

The EN54 Part 2 & 4 Fire System

IGD.CO.UK

Touch Screen 1 loop Addressable Fire Alarm Panel

ID2000. intelligent fire alarm panel

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

ACP10 & ACP50 Security Systems

CODESEC FIRE ALARM SYSTEMS. security technologies

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Sita200plus. 200detectors. Single loop analogue addressable System

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Different types of Fire Alarm System

General Alarm System. User Manual. Protec Fire Detection plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT, ENGLAND

FC700A Fire detection control unit

Intelligent Security & Fire Ltd

Conventional Fire Alarm System 2014 V1.2

Security Alarm Systems

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

Evolution Analogue Addressable Fire System

Wireless Fire & Security Solutions. Fire Product Showcase

Intelligent Addressable Fire Alarm System

Fire control panels FC360

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Building Technologies

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Fire detection and alarm system Operating instructions

SOLO Single Loop Addressable Fire Control Panel

Consultant Specification AGILE Wireless Fire Detection System

The new detector from Rafiki

Transcription:

Protec Protec Algo-Tec TM 6400 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE

CAUTION Protec Protec Algo-Tec 6400 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM The Protec Algo-Tec 6400 Interactive Digital Addressable System unwrapped: The Protec Algo-Tec protocol developed by Protec s in-house Research and Development team is utilised by the Protec Algo-Tec 6400 interactive digital addressable fire control system. Immunity to false alarms, more responsive fire detection, and ease of use has all been achieved to develop one of the most reliable systems available. Protec Algo-Tec 6400 The name Algo-Tec is a derivative of Protec algorithms. Algorithms are logical mathematical procedures for solving problems. Protec have developed fire detection algorithms coupled with fuzzy logic specifically designed to reduce unwanted fire alarms and to enhance the sensitivity of the system to true fire phenomenon. The Algo-Tec algorithms are exclusively utilised by the Protec Algo-Tec 6400 and 6300 Interactive Digital Addressable Fire Control Systems. Interactive Algo-Tec evaluates the data of each fire sensor and is able to learn from the information received. This may simply be to recognise that a sensor is becoming contaminated or in a dirty environment and to automatically adjust the alarm threshold to compensate for the background levels (Threshold Compensation). More complex Algo-Tec functions include the ability to discriminate between certain fire and non-fire conditions, filtering out certain environmental stimuli, such as steam from a hotel bathroom, and increasing the sensitivity of a sensor when an increase in temperature is detected. The net effect of the interaction between the sensors and the Algo-Tec decision making is enhanced performance, through immunity to false alarms and more responsive fire detection. Digital Addressable The data communication between the sensors and the control equipment is Digital. The Algo-Tec protocol utilised by the 6400 system enables high levels of data to be transferred, providing far more detailed information than was previously achievable with analogue addressable systems. It should however be noted that some analogue addressable systems use digital communication but do not transfer the high levels of data associated with the Algo-Tec protocol. Speed, stability, excellent EMC and security all serve to enhance the Algo-Tec Digital signalling. Why select analogue addressable when you can now choose Algo- Tec Digital Addressable? Algo-Tec 6000PLUS Interactive Decision Making Algorithms - Typical Applications Office Mode (High Performance) Computer Fire Day/Night Mode Offices DISCRIMINATING ALGORITHM Cigarette Smoke Day Mode: Office mode (high performance) Offices Night Mode: Clean mode (Extra high performance) Bin Fire Factory Loading Bay Clean Mode (Extra High Performance) Printer Paper Fire Day Mode: Heat detection only (6000PLUS/OPHT) Factory Loading Bay Night Mode: Smoke & Heat detection Bedroom Mode Computer Room Fire Chemical Fire DISCRIMINATING ALGORITHM Steam From Bathroom DISCRIMINATING ALGORITHM Aerosols in Bedroom Smoldering Fire NOTE: The above examples give an indication of system reaction to intermittent contaminants and typical fire sources in a correctly designed BS5839 system. They by no means detail the full complexity of the systems decision making algorithms. Examples are for 6000PLUS/OPHT. A D D R E S S I N G S A F E T Y S Y S T

Typical 6400 Network System FEATURES & BENEFITS Cost Effective - Distributed network of Display and Control Nodes (DCN s) and Loop Processing Nodes (LPN s) providing a cost effective solution for medium and large sized buildings and sites. Secure Network - Wired as a loop, the network s dual channel RS485 link ensures that no single fault will affect the system. Easy To Install - Alarm Sounders, Visual Alarm Devices, Interfaces, Manual Call Points and Sensors can all be loop powered. BUILDING 3 BUILDING 4 Reduced False Alarms - The Protec Algo-Tec TM 6000 interactive fire sensors utilise advanced discriminating algorithms for maximum reliability and immunity to false alarms. Up to 99 panels on a network Enhanced Performance - The Protec Algo-Tec TM 6000 sensors learn from their environment, applying interactive decision making algorithms to provide stability, threshold compensation and optimised performance. BUILDING 5A Secure Detection Loops - Many Protec Algo-Tec TM 6000 devices incorporate built-in short circuit isolator units. These can be located as required. Easy to Address - FAST TM (Firmware Addressed Secure Technology) ELIMINATES troublesome and time consuming setting of address cards and DIL switches. BUILDING 2 2 Core RS485 Secure Network Devices Display Address Number - RVAV Remote Visual Address Verification. Confirmation of the correct location of each device can be easily identified, using the devices in-built LED to indicate the device address number. BUILDING 1 BUILDING 5B Accurate Location of Fire Incidents - 16 characters of loop location text plus 60 characters of device location text ensure pinpoint accuracy of the location of an incident. A further 60 characters of alarm message text provide additional details of possible hazards and /or means of access. Full Site Control - All system controls and menus can be accessed from any Display and Control Node (DCN) location, including device isolation. On Site Flexibility - Configuration of all system functions is fully site programmable. Reduced Maintenance Costs - Early indication and reporting of sensors approaching contamination level, reduce false alarms and enable dirty sensors to be cleaned. Colour Graphics System True System Management - As each device incorporates a unique FAST TM serial number encoded during manufacture, TRUE SYSTEM MANAGEMENT is achievable, providing precise DEVICE history in addition to LOCATION history for a specific site system and total traceability of all devices manufactured from our commissioning files for quality management, using optional PC package. Designed to EN 54-2 & 4 E M S W I T H I N T E L L I G E N C E

Protec Protec Algo-Tec 6400 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM System Features Overview The Protec Algo-Tec 6400 is a fully distributed, networked interactive digital addressable fire detection and alarm system, ideally suited for medium and large sized buildings such as hotels, offices, universities, hospitals and complex industrial and commercial sites. Designed and manufactured by Protec, to comply with EN 54-2 & 4, the system architecture has been developed to provide a seamless network of Display and Control Nodes (6400/DCN s) and Loop Processing Nodes (6400/LPN s). The nodes can be located to suit the site structure and for convenience of wiring, enabling the loop and sounder circuit cabling to be wired locally to the nearest 6400/LPN and displayed at any 6400/DCN around the network. This eliminates the problem of routing all the system wiring to one central location, usually in the reception of a building or a security lodge with restricted space or access. The integrity of the system is also increased as the network is secure and an isolated incident cannot render the entire system inoperative. Secure Network A secure network interconnects all 6400 node options. The network is seamless with all system status and activities communicated around the network and accessible from any 6400/DCN location. The system cause and effect programming is stored within each 6400/DCN and 6400/LPN node for added security. Wired as a loop the network s dual channel fault tolerant RS485 ensures that no single fault can disable the system. In the unlikely event of multiple faults, each node will continue to function independently. Up to 99 nodes can be connected to the network. As all 6400/DCN s display and control the entire system network there is no need for a master panel as they all perform this function. This further enhances the integrity of the system. The network can be wired using copper or fibre optic cables. Loops The distributed nature of the 6400 system enables expansion by adding 6400/LPN Loop Processing Nodes to the system network. 6400/LPN s can be 2 or 4 loops. Each loop can accommodate up to 127 Protec Algo-Tec 6000 interactive addressable devices, totalling 508 addressable devices per 6400/LPN and a total network capacity of over 50,000 addressable devices. In addition to sensors, interfaces and manual call points, the loop can also support loop powered SOUNDERS, VISUAL DEVICE and OPTICAL BEAM DETECTORS. Loop powered sounder bases adopt the sensor address to increase the capacity of the loops still further. Node Options: 6400/DCN - Display and Control Node 6400/LPN - Loop Processing Node 6400/DCN/LPN - Combined DCN and LPN (2 nodes) 6400/RDN - Repeat Display Node 6400/RDN/LPN - Combined RDN and LPN (2 Nodes) 6400/MIMIC - Illuminated Mimic Node 6400/LPN 9000/BC8/24 6400/LPN The 6400/LPN nodes process the loop data from the field devices, communicate with other network nodes, and implement the cause and effects program for local and network fire signals. Sounder circuits and auxiliary change-over contacts are also controlled from the 6400/LPN. 6400/DCN/LPN The 6400/DCN and 6400/LPN are combined within a common enclosure. The appearance is the same as the 6400/DCN and uses the 6400/LPN back box to accommodate the cabling. 6400/MIMIC The Protec 6400 customised illuminated mimic can be connected to the network in the same way as other nodes. The LED indicators can be activated by the appropriate zone or specific device activation as defined and the mimic is available in a range of styles and finishes to suit the application. The 6400/MIMIC is a node on the network. 9000/BC8/24 The 9000/BC8/24 power supply is housed in a similar enclosure to the 6400/LPN and is finished in storm grey. The unit incorporates an 8 amp charger and 24Ah sealed lead acid cells. The charger provides a dual path 24V dc output for parallel supplies to the 6400/LPN or 6400/DCN nodes. A short circuit fault on one path is isolated and the load is provided via the second supply path. Power on and charger fault indications are displayed on the power supply secret until lit display and are also relayed to the 6400 network via the node being powered. A range of Protec 9000/BC power supplies are available with an extensive range of battery and charger sizes. A D D R E S S I N G S A F E T Y S Y S T

6400/DCN Overview Display and controls of the Algo-Tec 6400 system are via 6400/DCN s. All the functions of the 6400/DCN are accessed via a modern styled hinged lockable door, moulded from polycarbonate, finished in storm grey with a clear display viewing window, optional polished solid brass or brushed stainless steel finishes for recess mounting only. When opened, the door allows access to the system controls. These controls are SOUND S, SILENCE, ACCEPT and RESET push buttons plus a qwerty membrane keypad and arrow keys to enable access to the user menu facilities. The display consists of a quarter VGA graphics LCD with backlight, common FIRE indicator, 100 separate zonal fire LED s, power on, pre-alarm, supply fault, alarms silenced, system fault, print, alarms on, outputs disabled, fire link disabled, test, fault, alarm fault, fire link active, fire link fault, fire link delay, output delay & a print on demand 40 column low noise thermal printer. Two full duplex RS232 ports that are site configurable for baud rate/handshaking are available for site programming and interfacing to BMS, Colour Graphics or Pager systems. Liquid Crystal Display The 6400/DCN incorporates a quarter VGA backlit graphics LCD. In normal conditions the date and time is displayed and system status: normal. During a fire event the LCD will display the following:- Zone Number in Fire Loop Location Text (16 Characters) The Device Number in Alarm Date and Time of Incident Device Location Text (60 Characters) Device Alarm Message Text (60 characters) Number of devices in alarm The LCD also displays all faults, disablements, prealarms, user menus, past events and analogue values graphically in a bar graph. Zones The 6400/DCN has 100 separate secret until lit zonal fire LED indicators. Each addressable device can be allocated to any one of the 100 zones. Expansion panels are available to expand the zonal capacity to a maximum of 800 zones. Printer The integral printer is a 40 column low noise thermal printer. In operation the printer will print all system activities on demand detailing the date and time of event; the loop location text, and address number; 60 character device location text; and in alarm conditions, the alarm message text. By accessing the appropriate function from the user menu facility, reports can be printed detailing current faults, current disablements, past events, analogue values, loop devices, fire events or all events from the internal 2000 event historical log. 6400/MIMIC 6400 Hercules Colour Graphics System 6400/RDN The 6400/RDN node has all the functions detailed for the 6400/LCD and additionally has silence & reset push buttons to silence and reset active system fire events. All controls are housed behind a hinged lockable door, moulded from polycarbonate finished in storm grey. The 6400/RDN has an optional printer to print current fire events, fault events or disablements. The 6400/RDN is a node on the network. The 6400/RDN can also be combined with a 6400/ LPN in a common enclosure. 6400 Loop Powered LCD Repeat Display The 6400/LOOP/LCD can be connected directly to the local Algo-Tec TM digital addressable data loop and takes up just one address. The facia displays power, fire, fault, disablement and more alarms. Fire and fault events are displayed on the 4 x 40 character LCD display and automatically scroll. A backlight ensures that the events can be read in all lighting situations. Fire events have highest priority and inhibit the display of fault events. A new event initiates the internal buzzer and a mute button allows the internal buzzer to be muted. Loop standby/alarm load 75mA. Protec Colour Graphics System The Protec Colour Graphics System is a Windows based PC package providing a graphical representation of large sites enabling the precise location of an incident to be readily identified enabling a prompt response. Using a touch screen or mouse, the operator can track an incident and zoom from a site plan to intermediate plan listing floor levels, then zoom to a specific floor plan and if necessary then zoom to a specific detailed area within the floor plan showing the device in question. Colour prints of the maps can also be printed automatically or on demand. User Menu The user menu functions available include:- set time and date, display events, printer menu, disablement menu, test options, text editor menu, clear system fault and access codes. 32 access codes can be configured by entering a master user code. The access codes can be configured to restrict access to certain user menu functions. The disablement menu enables the user to disable any loop driven device on the 6400 network. When disabled the device is prevented from producing a fire condition on the system. Devices can be isolated by address number, address location text or by zone. Qwerty Keyboard The text editor menu function within the user menu, enables the user to edit the 60 character device location text and 60 character alarm text. The text is entered using the in-built qwerty membrane keypad on the front of the 6400/DCN. On Site Programming Recognising the problems associated with commissioning and maintaining a complex site, the 6400 system is site programmed using dedicated PC based programs. The entire system configuration can be downloaded from any 6400/DCN via the integral RS232 port and distributed using the 6400 network. The programming method not only reduces on site commissioning, but also provides copies of site data as a backup, stored remotely. Hard copies of the programming data can be provided via the PC software. E M S W I T H I N T E L L I G E N C E

Protec Protec Algo-Tec 6400 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM Loop Devices The Protec Algo-Tec 6000PLUS protocol utilises FAST addressing (Firmware Addressed Secure Technology). Every FAST device is manufactured with a unique serial number. FAST addressing ELIMINATES troublesome and time consuming address cards and DIL switching whilst being far more secure than soft addressing. The Protec Algo-Tec 6000PLUS sensor range has been developed to incorporate advanced fire sensing technology, electronic sounders, high intensity visual alarm and speech enhanced talking sounder capability, all integrated within the sensor head and powered from the loop. Typical Sensor Variants 6000PLUS/OPHT/S = c/w Sounder 6000PLUS/OPHT/VAD = c/w Visual Alarm Device 6000PLUS/OPHT/S VAD = c/w Sounder and Visual Alarm Device 6000PLUS/OPHT/TS = c/w Talking Sounder 6000PLUS/OPHT/TS VAD = c/w Talking Sounder and Visual Alarm Device 6000PLUS/HT FAST TM Interactive Heat Sensor - Interactive addressable heat sensor with low thermal mass thermistor, giving fast response to temperature increases. Other Heat Sensor variants include: 6000PLUS/HT/S, 6000PLUS/HT/SVAD 6000PLUS/HT/TSVAD Plant shutdown interface 6000/MICCO Heavy duty plant shutdown signal (Rated at 240V 5A) Zone circuit Single 2 wire loop cable LOOP 1 LOOP 2 EOL Monitored fire station Fire output & C/O contact Monitored fire station Fault output & C/O contact Bomb alert input Optional RS232 port: hercules colour graphics pager or BMS interface EOL 6400 Loop repeater Alarm circuit 6000/LPZA Loop powered zone alarm interface Sprinkler delay interface 6000/MICCO 2c Zone circuit 6000/LCM Local Control Module 9000/ BC6/24 4c supply EOL } } EOL Plant shutdown output (Rated at 240V 5A) Alarm circuit 8 Programmable monitored alarm outputs 6 Auxiliary fire C/O contacts } 4 x 24V Aux output } 4 x Software input switches 6000PLUS/OP FAST TM Interactive Optical Smoke Sensor - Interactive addressable high performance optical smoke sensor provide efficient reliable detection using the light scatter sensing principle with rapid response to a fire signal. Other Optical Sensor variants include: 6000PLUS/OP/S 6000PLUS/OPHT FAST TM Interactive Optical Heat Sensor - Interactive addressable high performance optical smoke and heat multi-sensor. Other Optical Heat Sensor variants include: 6000PLUS/OPHT/S, 6000PLUS/OPHT/VAD, 6000PLUS/OPHT/SVAD, 6000PLUS/OPHT/TS, 6000PLUS/OPHT/TSVAD 6000PLUS/OPHTCO FAST TM Interactive Optical Heat CO Sensor - Interactive addressable high performance optical smoke heat and carbon monoxide multi-sensor. Other Optical Heat Sensor variants include: 6000PLUS/OPHTCO/S, 6000PLUS/OPHTCO/L, 6000PLUS/OPHTCO/SL, 6000PLUS/OPHTCO/TSL KEY: 2 core secure network (RS485) 6000PLUS/BASE Low Profile Common Mounting Base - Compatible with the above range of Algo-Tec TM 6000PLUS Sensors. Heat Sensor Optical Smoke and Heat Sensor Optical Smoke, Heat and CO Sensor Monitored Input CC Output Interface Electronic Sounder Electronic Sounder VAD 6000PLUS/FFBASE Fast Fixed Base - Fast fixed recessed base is designed to recess the sensor into a false ceiling to give a lower profile view of the sensor. Duct Probe Unit c/w Smoke Sensor Manual Call Point Visual Alarm Device (VAD) 6400 Loop LCD Display 6400/LOOP/LCD Repeater - Connected directly to the local data loop and takes up just one address. The 2 x 40 character LCD Display provides clear text location of fire and fault events. Beam Detector Loop Powered Zone Alarm Interface Local Control Module 6400/DCN 6400/LPN 6400/RDN A D D R E S S I N G S A F E T Y S Y S T

Total Loop Load in Alarm (ma) Guide to loop cable conductor sizing for the Protec 6400 system. 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 Loop Length (Metres) 500 550 600 650 700 750 800 850 900 950 1000 6000/MCP FAST TM Addressable Manual Call Point - Key operated test facility, a loop short circuit isolator is incorporated. 6000PLUS/UG4DP Ventilation Duct Smoke Sensor Assembly - Single pipe air sampling unit for air speeds from 0.5 to 20m per sec. supplied with 6000PLUS/ BASE suitable for use with 6000PLUS/OP FAST TM interactive optical smoke sensor. 6000/FIREBEAM FAST TM Addressable Loop Powered Beam Detector - Combined transmitter/receiver unit and separate low level controller. With a beam range of 5-100 metres. 6000/SSR FAST TM Addressable Loop Powered High Output Electronic Sounder - utilises a Piezo driver unit to enable high sound output and very low current consumption. Total Loop Load in Alarm (ma) 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 Loop Length (Metres) 1050 1100 1150 1200 1250 1300 1350 1400 1450 1500 Table detailing the loop standby and alarm load for typical Algo-tec 6000 devices. Product Description The conductor size required as follows: 1.0mm 2 1.5mm 2 2.5mm 2 MAXIMUM LOOP RESISTANCE 16 OHMS PER CONDUCTOR No of Addresses Note: The following Loop Parameters should be observed 1) The total number of addressable devices should not exceed 127 per loop. 2) Add 20mA to total loop alarm load to allow for fire indicator LED s on devices 3) The total loop alarm load should not exceed 600mA per loop. Loop Standby Load ma Loop Alarm Load ma 6000/MCP Manual Call Point 1 0.45 0.85 6000/FIREBEAM Loop Beam 1 3.65 7 6000PLUS/HT Heat Sensor 1 0.2 0.2 6000PLUS/HT/S Heat Sensor c/w Sounder 1 0.4 5.4 6000PLUS/OPHT Optical Smoke and Heat Sensor 1 0.2 0.2 6000PLUS/OPHT/S 6000PLUS/OPHT/SVAD 6000PLUS/OPHT/TSVAD Optical Smoke and Heat Sensor c/w Sounder Optical Smoke and Heat Sensor c/w Sounder and Visual Alarm Device Optical Smoke and Heat Sensor c/w Talking Sounder and Visual Alarm Device 1 0.4 5.4 1 0.55 24 1 0.55 25 6000PLUS/OPHTCO Optical Smoke, Heat, and CO Sensor 1 0.45 0.45 6000PLUS/OPHTCO/S Optical Smoke, Heat, and CO Sensor c/w Sounder 1 0.45 5.45 6000/VAD/W Loop Visual Alarm Device 1 0.8 19 6000/SSR Loop Sounder 1 0.7 5 6000/SSR/VAD Loop Sounder Visual Alarm Device 1 0.7 24 6000/LCM Local Control Module 1 0.7 5 6000/MICCO Monitored Input CC Output 1 0.55 5 6000/VAD/W/RED FAST TM Addressable Loop Powered High Intensity VAD - Approved to EN54-23 the wall mounted VAD has a unique lens that distributes the white light in a cuboid pattern to achieve 7.5m x 7.5m coverage @ 2.4m high. 6000/VAD/C/RED FAST TM Addressable Loop Powered High Intensity VAD - Approved to EN54-23 the ceiling mounted VAD has a unique lens that distributes the white light in a cylindrical pattern to achieve 7.5m dia coverage @ 3m high. 6000/SSR/VAD 6000PLUS/TSR2 6000/FIU Flush Mounted Short Circuit Isolator Unit - To isolate a short circuit fault on either the incoming or outgoing loop cables. Suitable for a 30mm deep electrical mounting box. 6000/LPZA FAST TM Addressable Flush Mounted Loop Powered Zone Alarm Interface Unit - With a monitored detection circuit suitable for use with Protec 3000 series detection devices. Line continuity maintained. Monitored alarm output circuit rated at 24Vdc 50mA max. Suitable for a 45mm deep electrical mounting box. A loop short circuit isolator is included. 6000/LCM FAST TM Addressable Loop Powered High Output Electronic Sounder with VAD - Approved to EN54-3, 17 & 23 the wall mounted combined sounder/vad has a sound output of 100dB(A) @ 1m plus VAD light output of 7m x 7m coverage @ 2.4m high. FAST TM Addressable Loop Powered Talking Sounder - The 6000PLUS/TSR2 voice enhanced talking sounder is available with seven voice messages plus bell sound in addition to the three fire alarm tones compatible with the Protec range of electronic sounders. FAST TM Addressable Flush Mounted Local Control Module - Allows easy integration of Protec addressable fire detection systems into houses of multiple occupany and offers novel features to reduce false alarms. The interface drives a zone of 3000 series detection devices and provides a supply to a local alarm circuit. 6000/MICCO FAST TM Addressable Flush Mounted Loop Powered Monitored Input, Clean Contact Output Interface Unit - With a monitored input circuit suitable for use with simple switch devices and the output is a clean changeover contact 5amp rated at 240V ac. A link can be cut to provide a 7-second delay to the input. Suitable for a 45mm deep electrical mounting box. A loop short circuit isolator is incorporated. Multi-way Input/Output Interfaces - A range of 16 way input/ output interfaces are available with monitored alarm outputs or clean changeover contacts. All interfaces are FAST TM addressable. E M S W I T H I N T E L L I G E N C E

Technical Specification 6400 Series Common Specifications Temperature Range 0-40 C. Maximum Humidity 85% Non-Condensing. Working Voltage 21.5-30V dc. Secure Network Dual channel RS485 fault tolerant communications network for up to 100 nodes. 3 wire loop (2 Data & 0V), maximum 1km between nodes. Node Power Supply Fault monitored dual path 24V dc from 6400/BC range PSU 4 wire plus 2 wire (2 Primary Power, 2 signals) (2 Sec. Power). Total Node Load Maximum load to a 6400/LPN or 6400/DCN/LPN is 6A. 6400/DCN 210mA. 390mA. Display Quarter VGA Backlit Graphics LCD. Zones 100 Zone Fire indicators, plus common FIRE indicator. Expandable to 800. Printer 40 column low noise thermal printer. Nodes The 6400/DCN counts as one node on the network. RS232 Ports Two full duplex RS232 ports for site programming, BMS, Colour Graphics or pager system interfacing. Auxiliary Output Supply Two sets of 24V dc output terminals. Total load 1A. Common Fire Output (fire station) 24V dc fully monitored output rated at 20mA. 1K EOL. Common Fault Output (fire station) 24V dc fully monitored output rated at 20mA. 1K EOL. 440(W) x 385(H) x 104(D). Approvals LPCB Certificate No: 201ad/01, EC Certificate No: 0832-CPD-1434, Relevant Standard: EN 54-2. MANAGEMENT SYSTEMS LPCB ref. no. 201ad 6400/LPN 250mA (2 loop) 310mA (4 loop). 480mA (2 loop) 540mA (4 loop). Analogue Addressable Loops 2 to 4 loops, each with 127 address capacity per loop. Total 6400/LPN capacity 4 loops, 508 addresses. Total Loop Load 600mA per loop including all loop connected devices. Nodes The 6400/LPN counts as one node on the network. Programmable Alarm Outputs 8 monitored 24V dc sounder circuits 1A rated. 47K EOL. 6 non monitored - clean changeover contacts (1A rated @24V). Expansion modules available to increase alarm output capability. Up to 127 programmable alarm outputs per loop using loop output devices. Total node load 6A. Auxiliary Output Supply Four sets of 24V dc output terminals. Total load 1A. Common Fire Output (fire station) 24V dc fully monitored output rated at 20mA. 1K EOL. Dedicated Clean Changeover contacts (1A rated @24V). Common Fault Output (fire station) 24V dc fully monitored output rated at 20mA. 1K EOL. Dedicated Clean Changeover contacts (1A rated @24V). Software Input Switches Class change, bomb alert. Plus four additional non-dedicated inputs for day/night mode, etc. 440(W) x 385(H) x 144(D). Approvals (2 loop) LPCB Certificate No: 201ad/02, EC Certificate No: 0832-CPD-1435, Relevant Standard: EN 54-2 & 4. (4 loop) LPCB Certificate No: 201ad/03, EC Certificate No: 0832-CPD-1436, Relevant Standard: EN 54-2 & 4. 6400/DCN/LPN Overview Combined 6400/DCN and 6400/LPN nodes within a common enclosure. The full specification for a 6400/LPN applies plus DCN controls. Standby load (Mains Fail Condition) 380mA (2 loop) 440mA (4 loop). 770mA (2 loop) 830mA (4 loop). Nodes The 6400/DCN/LPN counts as TWO nodes on the network. 440(W) x 385(H) x 144(D). Approvals (2 loop) LPCB Certificate No: 201ad/04, EC Certificate No: 0832-CPD-1437, Relevant Standard: EN 54-2 & 4. (4 loop) LPCB Certificate No: 201ad/05, EC Certificate No: 0832-CPD-1438, Relevant Standard: EN 54-2 & 4. 6400/RDN or 6400/MIMIC Working Voltage Nodes Outputs 150mA. 220mA. 21.5-30V dc from LPN,DCN or local PSU. The 6400/RDN or 6400/MIMIC each counts as one node on the network. Local fault clean changeover contacts (1A rated @ 24V). 440(W) x 385(H) x 104(D). 6400/LOOP/LCD 75mA. 75mA. Working Voltage Loop powered. Loop Addresses 1. 360(W) x 215(H) x 47(D). 9000/BC8/24 Complies with EN 54-4. 90mA. Power Supply Mains nominal +/- 10%. Integral Charger 8A. Integral Battery 24Ah 24V Sealed lead acid. Dual path output O/P1-24V dc Primary supply. O/P2-24V dc secondary supply. Output path is automatically switched if a S/C fault is detected. Supply fault signal Communicated to nearest connected 6400 node. Charger inhibit input From 6400 node during fire conditions to increase output to 8A. Wiring to 6400 Node 4 wire plus 2 wire (2 primary power, 2 signals) (2 sec. power). 440(W) x 385(H) x 200(D). Approvals LPCB Certificate No: 201ad/06, EC Certificate No: 0832-CPD-1439, Relevant Standard: EN 54-4. Protec: Scotland Tel: 0845 456 5390 Fax: 0845 456 5391 Protec: North East Tel: 0845 456 5396 Fax: 0845 456 5397 Protec: Yorkshire Tel: 0845 456 5388 Fax: 0845 456 5389 Protec: Midlands Tel: 0845 456 5398 Fax: 0845 456 5399 Protec: South East Tel: 0845 456 5394 Fax: 0845 456 5395 Protec: South West Tel: 0845 456 5392 Fax: 0845 456 5393 Company Policy is one of continuous improvement, we reserve the right to change specification without prior notice Protec Fire Detection Plc, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT Tel: 01282 717171 Fax: 01282 717273 Web: www.protec.co.uk Email: sales@protec.co.uk MED1510 Issue 3 N 92-049-63C