Technical Application Guide for UP-SHINE LED Frameless Panel Light UP-PL66-45W-P
Introduction Frameless panel is an improved version compared to regular panels.they are of high lumen output, high CRI>8, top branded driver with stable working performance. Dimmable version comes with triac dim, -1V dim, DALI dim, it shares great popularity by perfect dimming range and great compatibility with worldwide dimmers. The Frameless structural design makes it special and elegant. 5mm thickness diffuser with extremely even light output provides high quality lighting effect. Up to 8% energy saving compared to standard CFL Long lifetime of 4, hours Dimmable when using triac dimmer 12 wide beam angle CCT: 3K 4K 5K 57K No UV/IR light Environment friendly, without Mercury or any other hazardous substances Application notes IP4 for indoor use Professional electrician for installation only Switch off before installation Do not touch when in use Keep away from hot steam and corrosive gas Application Areas Widely used for various commercial lighting and residential lighting applications, such as office, shopping mall, hotel, restaurant, hospital, home lighting etc. Certificates SAA
Product Information Technical Specifications Model Voltage Power Power Factor Lumen (±5%) Beam angle CCT Lifespan CRI Dimmable Dimension UP-PL66-45W-P AC1-24V 45W.9 37 12 o 3K 4h 8 No 595*595*16mm UP-PL66-45W-P AC1-24V 45W.9 38 12 o 4K 4h 8 No 595*595*16mm UP-PL66-45W-P AC1-24V 45W.9 385 12 o 5K 4h 8 No 595*595*16mm UP-PL66-45W-P AC1-24V 45W.9 395 12 o 57K 4h 8 No 595*595*16mm UP-PL66-45W-P-D AC23V 45W.9 355 12 o 3K 4h 8 Yes 595*595*16mm UP-PL66-45W-P-D AC23V 45W.9 36 12 o 4K 4h 8 Yes 595*595*16mm UP-PL66-45W-P-D AC23V 45W.9 368 12 o 5K 4h 8 Yes 595*595*16mm UP-PL66-45W-P-D AC23V 45W.9 375 12 o 57K 4h 8 Yes 595*595*16mm Driver data Sheet Driver data DIM Non-dim Input rated Voltage AC23V AC1-24V Frequency 5Hz 5/6Hz Input Voltage AC2-24V AC85-265V Efficiency 83% 86% Total load Wattage 45W±5% 45W±5% Power Factor.9.9 Rated input current.25a.5a Full load output Voltage DC35-38V DC35-38V Rated output current 1mA 15mA Output current range 1mA±5% 15mA±5% Power tolerance ±5% ±5% Current output tolerance ±5% ±5% Dimming range 8%-1% Dimmer Triac dimmers Short circuit protection PASS PASS Over voltage protection PASS PASS Over temperature protection PASS PASS Withstand voltage AC375V AC375V Fixture Compatibility Rated Wattage Electrical Classification Ingress Protection Operating Temp Operating Humidity Storage Temp 45W II IP4-2 o C~45 o C ~9% -2 o C~65 o C
Spectral Distribution 3K 4K.8 Max=6783 [1.=2] 2.83SDCM F3K.8 Max=6384 [1.=2] 3.86SDCM F4K.7.7.6.6.5.4.3 x=.4456 y=.464.5.4.3 x=.4472 y=.417.2.2.1.1. 38 5 6 7 8. 38 5 6 7 8 5K 57K.8.7.6 Max=5311 [1.=2] 3.24SDCM F5K.8 Max=5721 [1.=2].7.6 3.6SDCM F57K.5.4.3 x=.354 y=.3684.5.4.3 x=.3523 y=.3684.2.2.1.1.. 38 5 6 7 8 38 5 6 7 8 Photometric Diagram 3K 4K -12-9 -/+18 3 12 9 15. 12. MH=1m C/18 C9/27 Flux out: 2787 lm 3.281ft 34.76,121.9fc 1m 374.2,1312lx 6.562ft 8.691,3.46fc 2m 93.55,327.9lx 9.997ft 34.7cm 19.99ft 69.4cm -12-9 -/+18 9 12 9 15. 12. MH=1m C/18 C9/27 Flux out: 2857 lm 3.281ft 35.63,124.6fc 1m 383.5,1341lx 6.562ft 8.97,31.16fc 2m 95.88,335.4lx 1.1ft 37.85cm 2.2ft 615.7cm 6 9. 3.863,4fc 48,145.7lx 29.99ft 914.9cm 18 9. 3.959,13.85fc 42.61,149.lx 3.3ft 923.55cm 9 6. 27 6. 12 2.173,7.616fc 23.39,81.98lx 39.99ft 1218.79cm 36 2.227,7.789fc 23.97,83.84lx 4.4ft 1231.4cm 15-3 3 AVERAGE BEAM ANGLE(5%): 113.6 DEG 3. -25-2 -15-1 -5 5 1 15 2 25 16.4ft 1.391,4.874fc 49.98ft 5m 14.97,52.47lx 1523.49cm Height Eavg, Emax Angle: 113.44deg Diameter 45-3 3 AVERAGE BEAM ANGLE(5%): 114. DEG 3. -25-2 -15-1 -5 5 1 15 2 25 16.4ft 1.425,4.985fc 5.5ft 5m 15.34,53.66lx 1539.25cm Height Eavg, Emax Angle: 113.98deg Diameter 5K 57K -12-9 -/+18 9 12 9 15. 12. MH=1m C/18 C9/27 Flux out: 2788 lm 3.281ft 34.77,122.1fc 1m 374.3,1315lx 6.562ft 8.693,3.53fc 2m 93.57,328.6lx 1.1ft 34.99cm 2.1ft 69.98cm -12-9 -/+18 9 12 9 15. 12. MH=1m C/18 C9/27 Flux out: 2918 lm 3.281ft 36.39,127.6fc 1m 391.7,1374lx 6.562ft 9.98,31.91fc 2m 97.93,343.4lx 1ft 34.87cm 2ft 69.74cm 18 9. 3.863,7fc 49,146.1lx 3.2ft 914.96cm 18 9. 4.43,14.18fc 43.52,152.6lx 3.1ft 914.61cm 27 6. 27 6. 36 2.173,7.633fc 23.39,82.16lx 4.2ft 1219.95cm 36 2.274,7.977fc 24.48,85.86lx 4.1ft 1219.49cm 45-3 3 AVERAGE BEAM ANGLE(5%): 113.3 DEG 3. -25-2 -15-1 -5 5 1 15 2 25 16.4ft 1.391,4.885fc 5.3ft 5m 14.97,52.58lx 1524.94cm Height Eavg, Emax Angle: 113.49deg Diameter 45-3 3 AVERAGE BEAM ANGLE(5%): 113.6 DEG 3. -25-2 -15-1 -5 5 1 15 2 25 16.4ft 1.456,5.15fc 5.1ft 5m 15.67,54.95lx 1524.36cm Height Eavg, Emax Angle: 113.47deg Diameter
Polar Diagram Comparison -15 O +/-18 O 15 O -12 O 12 O -9 O 9 O 3 6-6 O 9 6 O 12-3 O 15 3 O O AVERAGE BEAM ANGLE (5%): 113.6DEG C/18, 1 deg C3/21, 113.2 deg C6/24, 113.6 deg C9/27, 114. deg Driver lifetime & LED light decay rate Driver Lifetime LED Light Decay Rate 9 11%.4 Lifetime (hours) 8 7 6 5 4 3 2 1 65 o C 75 o C 85 o C 95 o C 15 o C Capacitor Tc ( o C) % Luminous Flux 15% 1% 95% 9% 85%.35.3.25.2.15 8% 75% FLUX.1.5 U'V' 7%. 1 2 3 4 5 6 7 8 9 1 LifeTime (hours) Temperature The testing is operated at 25 C The lifetime of capacitor, minimum of 5, hours if operated at 15 C, will be doubled whenever the temperature drops 1 C The highest withstand temperature of IC, MOS could be 12 C The highest withstand temperature of LED junction temperature is 15 C 8 Temperature ( o C) 7 6 5 4 3 2 1 16:36:53 17:27:51 18:18:51 19:9:51 2::51 2:51:51 21:42:51 22:33:51 23:24:51 :15:51 1:6:51 1:57:51 2:48:51 3:39:51 4:3:51 5:21:51 6:12:51 7:3:51 7:54:51 8:45:51 Time The driver lifespan is based on capacitor working temperature. IC Capacitor MOS PCB LED Fitting Environmental temperature
Installation 1.Recessed into ceiling 1. Remove ceiling plaster slab. 2. Connect power supply. 3. Fix the panel light into right place. 4. Stabilize the panel. 2. Suspending 1. Fastening the bracket on the ceiling with plastic anchor and screw. 2. Put the DC line through the mounting box and connect the power supply. 3. Connect one end of steel wire with panel, another end with mounting box. 4. Hang the mounting box back to the bracket.
3. Suspending 1. Fix the plastic anchoring into suitable place on the ceiling 2. Use the tapping screw fix the installation mount with the plastic anchoring on the ceiling 3. Let the steel wire with knot end through clips s hole on panel. Fix the wire s another side with the installation mount. 4. Adjust the steel wire to a suitable length. Connect with power supply. Turn on the LED panel light. Packaging Information SIZE(CM) N.W/pc (KGS) G.W.(KGS) Q'TY(PCS) Carton 66.5*21*73 5.1 2 4 CTNS Q'TY(PCS) VOLUME(CBM) 2'' standard container 4'' standard container 25 1 28 5 2 56 Phone: +86 755 2919 7332 Add: 2nd building Dingfeng High-Tech Zone, Fuyuan 1st road, Fu Yong Sub-district, Bao'an, Shenzhen China