WALL MOUNTED UNITS SDH W SDH W SDH W SDH W

Similar documents
1. Features Specification Dimensions Refrigeration cycle diagram Operation limits

Content Precaution...2 Function...3 Dimension...5 Refrigerant cycle diagram...7 Operation limits...8 Wiring diagram...9 Installation details...

High Wall SERVICE MANUAL. TLCA-TLHA 07 to 18 FSAAAR TLCA-07 / TLHA-07 TLCA-09 / TLHA-09 TLCA-12 / TLHA-12 TLCA-18 / TLHA-18 SM-TLCA-TLHA-07-18GB 06-08

Cover. Service Manual PAC9037 PAC12037 PAC13037 PAC18037

Service Manual. Room Air Conditioner Split Wall-Mounted Type. Applies to: HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1

Service Manual. Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM

Technical & service manual 2005

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Operating Functions Temperature Parameters

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series

Pure Efficiency Meets Healthy Living NEW 2013

Ceiling & Floor type Unit

F SERIES ON-OFF SERIES. Service Manual 2016

BTU Units WORKING PROGRAM MANUAL

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

Room Air Conditioner CONTENTS CS-E9BKP CU-E9BKP5 CS-E12BKP CU-E12BKP5. Order No: MAC C2

Light Commercial SUPER INVERTER SERIES MULTI TYPE

Service Manual AIR CONDITIONER

Product Data FEATURES AND BENEFITS. QHF 50Hz Heat Pump Inverter Single Phase 2.5kW to 8.0kW

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

Floor-Standing Type(E Series)

YC ON-OFF SERIES. Service Manual

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

Westinghouse. Split System Inverter Series. Service Manual

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Ducted inverter reverse cycle air conditioning

Wired Controller XK60

Before using your air conditioner, please read this manual carefully and keep it for future reference. ACDC12B

Air to air heat pump range. Why Vaillant? because there is something in the air.

Hi - Wall Split Systems 12K - 18K - 24K

American Brand with Global Reach. Heat Pump Decorative Wall Mount Split Unit

VMI-1102-A SERVICE MANUAL AIRCONDITIONER DC INVERTER MULTI TYPE MSV1I-09HRDN1-M TAS-09MVHN TAS-12MVHN INDOOR VERTU DC INVERTER MULTI SERIES

SERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

Installation, Operation & Maintenance

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

SERVICE MANUAL SPLIT WALL-MOUNTED TYPE MODELS MWCOHC30S/MRCOHC30AS MWCOHC36S/MRCOHC36AS

SPLIT TYPE AIR CONDITIONER WAS-09HSTD WINTAIR

WORKING PROGRAM. Heating dehumidifying cooling T 27

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Inverter Wall Mounted Series

50A KP 70A KP 90A KP 120A KP 150A KP 210A

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

3. INDOOR UNIT OPERATION

TAC-09CHSA/*** TAC-12CHSA/*** TAC-18CHSA/*** TAC-24CHSA/*** SERVICE MANUAL WALL MOUNTED SPLIT-TYPEAIR CONDITIONERS. No.TE1307.

Service Manual for TAS-18EHN, TAS-24EHN

SERVICE MANUAL INVEST HEAT PUMP DC INVERTER SPLIT WALL-MOUNTED TYPE MSC-24/QD FP MSH-24/QD FP

C&H NORDIC Commercial 4 SERVICE MANUAL

CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS

KSIM20912-H216 KSIM30912-H216 KSIM40912-H216

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

MULTI INVERTER SERIE H6M

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Cassette type Duct type Ceiling type INVERTER AO* G45LETL AO* G54LETL

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

SEMTIC HEATING

FROZEN SERIE SERVICE MANUAL. DC Inverter R32. Sistemi per la climatizzazione

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

COLDWAVE. Portable Air Conditioner. Model MPPD-12CRN BTU/h 110V/1Ph/60Hz R410A

ENGINEERING MANUAL FOUR FUNCTION

Hot Water Heating Systems

AIR CONDITIONING SYSTEMS WALL MOUNTED UNIT

Corona Plus varmepumper

ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO

NORTH AMERICAN HVAC PRODUCTS LTD. Tel: Fax: DC Inverter Single Zone Split Wall-Mounted Type

NORTH AMERICAN HVAC PRODUCTS LTD. Tel: Fax: DC Inverter Single Zone Split Wall-Mounted Type

KMIR218-H221 / KMIR327-H217 / KMIR436-H217 / KMIR545-H219

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

TROUBLESHOOTING TROUBLESHOOTING. Indoor unit EEPROM parameter error. Indoor / outdoor units communication error. Zero-crossing signal detection error

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

MODEL: CCT 301 INV CCT 501 INV CCT 70 INV-S CCT 100 INV-S CCT 140 INV-S CCT 170 INV-S

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

1. Dimensions Service Space Piping Diagrams Wiring Diagrams Electric Characteristics...

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

TECHNICAL GUIDE MODELS: DCPM/DHPM PREMIUM SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 22 SEER 1 PHASE 3/4 THRU 3 NOMINAL TONS

CONTROL PANEL INSTRUCTIONS RSQ-4

Brief exposure to greenery in urban environments can relieve stress levels and your well-being.

Air Conditioner CONTENTS

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

Remote Controller Manual

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

HI-WALL SPLIT SYSTEMS

Wired Remote Controller XK19 and Wireless Remote Controller YT1F

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

2 &3-4 Head Multi System

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

Q Series. Inverter Split Systems

SERVICE MANUAL Room Air Conditioner DC Inverter Multi Split Outdoor units

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Ductless Split Systems Ceiling Cassette Heat Pumps

Blanc ON-OFF Series. Service Manual 2016

ART الرفاهية تكنولوچيا بلمسة فنية

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

Transcription:

WALL MOUNTED UNITS Technical Dossier WALL MOUNTED UNITS SDH 14-026 W SDH 14-036 W SDH 14-051 W SDH 14-065 W 2010

1- CONTENTS 1- Contents... 2 2- Technical specifications... 3 3- Temperature by capacities... 5 3.1- SDH 14-026 W...5 3.2- SDH 14-036 W...6 3.3- SDH 14-051 W...7 3.4- SDH 14-065 W...8 4- Wiring diagrams... 9 5- Error codes... 11 6- Flow chart of diagnosis and solutions...12 6.1-026-036-051... 12 6.2-065... 15 7- PCB Explanation...18 7.1- Proper symbols and their meaning...18 7.2- Function...18 7.3- Protection... 19 7.4- Fan-only mode... 19 7.5- Cooling mode...20 7.6- Dehumidifying mode... 21 7.7- Heating mode... 21 7.8- Defrosting mode...23 7.9- Auto mode...24 7.10- Force cooling function...25 7.11- Sleep mode...25 7.12- Auto restart function...25 7.13- Turbo mode...25

2- TECHNICAL SPECIFICATIONS Model SDH 14-026 W SDH 14-036 W SDH 14-051 W SDH 14-065 W Indoor unit 14-026 HWI 14-036 HWI 14-051 HWI 14-065 HWI Outdoor unit 14-026 HWO 14-036 HWO 14-051 HWO 14-065 HWO Power supply V/Ph/Hz 230/1/50 kw 2,65 3,25 5,15 7,03 Cooling capacity BTU 9.044 11.092 17.576 23.992 Fg/h 2.279 2.795 4.429 6.046 Power input kw 0,82 1,01 1,71 2,45 Nominal capacity (UK condit) kw 2,53 3,06 4,63 6,93 Power input (UK conditions) kw 0,66 0,83 1,38 1,96 Operating current A 3,70 4,40 7,70 11,50 EER 3,23 3,22 3,01 2,87 Energy level class A A B C Annual consumption kwh 415 520 860 1.225 kw 2,80 3,30 5,40 7,91 Heating capacity BTU 9.556 11.262 18.429 26.995 Kcal/h 2.408 2.838 4.644 6.803 Power input kw 0,77 0,91 1,67 2,46 Nominal capacity (UK condit) kw 2,21 2,83 4,27 6,57 Power input (UK conditions) kw 0,72 0,90 1,52 2,14 Operating current A 3,50 3,90 7,20 11,50 COP 3,64 3,63 3,23 3,22 Energy level class A A C C Max power input kw 1,10 1,40 2,60 3,50 Max operating current A 5,50 7,50 13,00 18,00 INDOOR UNIT Air flow volume m3/h 320 / 380 / 450 420 / 500 / 580 600 / 730 / 800 960 / 1020 / 1080 Remote control type Wireless - Infrared Wireless - Infrared Wireless - Infrared Wireless - Infrared Remote control reference R19 A/E R19 A/E R19 A/E R19 A/E Sound pressure db(a) 28 / 34 / 40 30 / 37 / 42 32 / 39 / 43 33 / 40 / 44 Testing conditions for sound pressure Microphone directivity, distance 1.0m Dimensions HxLxD mm 275 x 790 x 190 275 x 790 x 190 275 x 940 x 198 313 x 1030 x 221 Net weight Kg 9 9 10 14 Packaged dimensions HxLxD mm 350 x 865 x 265 350 x 865 x 265 350 x 1015 x 270 435 x 1135 x 315 Volume 0,080 0,080 0,096 0,156 Packaged weigth 11,0 11 13,5 20,0 3

2- TECHNICAL SPECIFICATIONS SDH 14-026 W SDH 14-036 W SDH 14-051 W SDH 14-065 W OUTDOOR UNIT Air flow volume m3/h 1.500 1.800 2.200 2.500 Sound pressure db(a) 50 50 52 53 Number of fans 1 1 1 1 Refrigerant R410A R410A R410A R410A Refrigerant charge heat pump gr 620 790 1.230 2.000 Compressor type Rotary Rotary Rotary Rotary Compressor Model PA103M1C-4DZDE2 PA118M1C-4FZ2 PA200X2CS-4KU1 PA290X3CS-4MU1 Compressor Brand Toshiba Toshiba Toshiba Toshiba Expansion system Capillary Capillary Capillary Capillary Electric_electronic protections Voltage protection; current protection; communication protection Dimensions HxLxD mm 550 x 700 x 230 540 x 780 x 250 590 x 760 x 285 695 x 845 x 335 Dimensions Valves A/B/C mm 60 / 60 / 145 60 / 60 / 145 60 / 60 / 145 85 / 85 / 160 Dimensions Installation I/J mm 240 / 460 280 / 550 290 / 530 275 / 554 Net weight Kg 24,5 26 39 62 Packaged dimensions HxLxD mm 580 x 815 x 325 575 x 910 x 335 655 x 887 x 355 655 x 887 x 355 Volume 0,154 0,175 0,206 0,206 Packaged weight heat pump Kg 26,5 28 42 65 INSTALLATION Pipe connection liq/gas inches 1/4-3/8 1/4-3/8 1/4-1/2 3/8-5/8 PM (Max pressure) bar 42 42 42 42 pm (min pressure) bar 15 15 15 15 Max. Piping length m 20 20 25 25 Max. Height IU under OU m 10 10 10 10 Max. Height OU under IU m 10 10 10 10 Chargeless length m 5 5 5 5 Additional charge per meter gr 30 30 30 40 4

3- TEMPERATURE BY CAPACITIES 3.1 sdh 14-026 w Cooling OUTDOOR TEMPERATURE DRY Indoor Conditions 21ºC 25ºC 30ºC 35ºC 40ºC 45ºC 21ºC D 15ºC W 24ºC D 17ºC W 27ºC D 19ºC W 32ºC D 23ºC W Total capacity kw 2,45 2,43 2,41 2,36 1,89 1,77 Sensitive capacity kw 1,96 1,94 1,92 1,89 1,51 1,42 Input kw. 2,76 2,74 2,72 2,67 2,75 2,86 Total capacity kw 2,51 2,48 2,46 2,41 1,93 1,81 Sensitive capacity kw 2,01 1,99 1,97 1,93 1,54 1,45 Input kw. 0,83 0,82 0,82 0,80 0,82 0,86 Total capacity kw 2,76 2,73 2,70 2,65 2,12 1,99 Sensitive capacity kw 2,20 2,18 2,16 2,12 1,70 1,59 Input kw. 0,85 0,84 0,84 0,82 0,84 0,88 Total capacity kw 3,09 3,06 3,03 2,97 2,37 2,23 Sensitive capacity kw 2,47 2,45 2,42 2,37 1,90 1,78 Input kw. 0,95 0,94 0,94 0,92 0,95 0,98 HEATING Indoor Conditions 15ºC 18ºC 20ºC 22ºC 27ºC OUTDOOR CONDITIONS 24ºC D 18ºC W 12ºC D 11ºC W 7ºC D 6ºC W 4ºC D 3ºC W 0ºC D -1ºC W -5ºC D -6ºC W -7ºC D -8ºC W Capacity kw 3,59 3,55 3,11 2,55 2,18 1,71 1,59 Input kw. 0,99 0,97 0,85 0,79 0,77 0,68 0,66 Capacity kw 3,43 3,39 2,97 2,43 2,08 1,63 1,51 Input kw. 0,94 0,93 0,81 0,75 0,74 0,65 0,63 Capacity kw 3,23 3,20 2,80 2,30 1,96 1,54 1,43 Input kw. 0,89 0,88 0,77 0,71 0,70 0,61 0,60 Capacity kw 2,75 2,72 2,38 1,95 1,67 1,31 1,21 Input kw. 0,82 0,81 0,71 0,66 0,64 0,57 0,55 Capacity kw 2,75 2,72 2,38 1,95 1,67 1,31 1,21 Input kw. 0,83 0,82 0,72 0,66 0,65 0,57 0,56 ENG 5

3- TEMPERATURE BY CAPACITIES 3.2 sdh 14-036 w Cooling OUTDOOR TEMPERATURE DRY Indoor Conditions 21ºC 25ºC 30ºC 35ºC 40ºC 45ºC 21ºC D 15ºC W 24ºC D 17ºC W 27ºC D 19ºC W 32ºC D 23ºC W Total capacity kw 3,01 2,98 2,95 2,89 2,31 2,17 Sensitive capacity kw 2,41 2,38 2,36 2,31 1,85 1,74 Input kw. 3,30 3,28 3,25 3,19 3,28 3,41 Total capacity kw 3,08 3,05 3,02 2,96 2,37 2,22 Sensitive capacity kw 2,46 2,44 2,41 2,37 1,89 1,77 Input kw. 1,02 1,01 1,00 0,99 1,01 1,05 Total capacity kw 3,38 3,35 3,32 3,25 2,60 2,44 Sensitive capacity kw 2,70 2,68 2,65 2,60 2,08 1,95 Input kw. 1,05 1,04 1,03 1,01 1,04 1,08 Total capacity kw 3,79 3,75 3,71 3,64 2,91 2,73 Sensitive capacity kw 3,03 3,00 2,97 2,91 2,33 2,18 Input kw. 1,17 1,16 1,15 1,13 1,17 1,21 ENG HEATING Indoor Conditions 15ºC 18ºC 20ºC 22ºC 27ºC OUTDOOR CONDITIONS 24ºC D 18ºC W 12ºC D 11ºC W 7ºC D 6ºC W 4ºC D 3ºC W 0ºC D -1ºC W -5ºC D -6ºC W -7ºC D -8ºC W Capacity kw 4,23 4,18 3,66 3,00 2,56 2,01 1,87 Input kw. 1,16 1,15 1,01 0,93 0,91 0,80 0,78 Capacity kw 4,04 3,99 3,50 2,87 2,45 1,92 1,78 Input kw. 1,11 1,10 0,96 0,89 0,87 0,77 0,75 Capacity kw 3,81 3,77 3,30 2,71 2,31 1,82 1,68 Input kw. 1,05 1,04 0,91 0,84 0,82 0,72 0,71 Capacity kw 3,24 3,20 2,81 2,30 1,96 1,54 1,43 Input kw. 0,97 0,96 0,84 0,78 0,76 0,67 0,65 Capacity kw 3,24 3,20 2,81 2,30 1,96 1,54 1,43 Input kw. 0,98 0,97 0,85 0,78 0,77 0,67 0,66 6

3- TEMPERATURE BY CAPACITIES 3.3 sdh 14-051 w Cooling OUTDOOR TEMPERATURE DRY Indoor Conditions 21ºC 25ºC 30ºC 35ºC 40ºC 45ºC 21ºC D 15ºC W 24ºC D 17ºC W 27ºC D 19ºC W 32ºC D 23ºC W Total capacity kw 4,67 4,63 4,58 4,49 3,59 3,37 Sensitive capacity kw 3,74 3,70 3,67 3,59 2,88 2,70 Input kw. 5,05 5,02 4,98 4,88 5,03 5,22 Total capacity kw 4,78 4,73 4,69 4,59 3,68 3,45 Sensitive capacity kw 3,82 3,79 3,75 3,68 2,94 2,76 Input kw. 1,73 1,71 1,70 1,67 1,72 1,78 Total capacity kw 5,25 5,20 5,16 5,15 4,04 3,79 Sensitive capacity kw 4,20 4,16 4,12 4,04 3,23 3,03 Input kw. 1,77 1,76 1,74 1,71 1,76 1,83 Total capacity kw 5,88 5,82 5,77 5,65 4,52 4,24 Sensitive capacity kw 4,70 4,66 4,61 4,52 3,62 3,39 Input kw. 1,98 1,97 1,95 1,92 1,97 2,05 HEATING Indoor Conditions 15ºC 18ºC 20ºC 22ºC 27ºC OUTDOOR CONDITIONS 24ºC D 18ºC W 12ºC D 11ºC W 7ºC D 6ºC W 4ºC D 3ºC W 0ºC D -1ºC W -5ºC D -6ºC W -7ºC D -8ºC W Capacity kw 6,92 6,85 5,99 4,92 4,20 3,30 3,06 Input kw. 2,14 2,11 1,85 1,71 1,67 1,47 1,43 Capacity kw 6,61 6,54 5,72 4,69 4,01 3,15 2,92 Input kw. 2,04 2,02 1,77 1,64 1,60 1,41 1,37 Capacity kw 6,24 6,17 5,40 4,43 3,78 2,97 2,75 Input kw. 1,93 1,91 1,67 1,55 1,51 1,33 1,29 Capacity kw 5,30 5,24 4,59 3,76 3,21 2,52 2,34 Input kw. 1,78 1,76 1,54 1,43 1,39 1,23 1,19 Capacity kw 5,30 5,24 4,59 3,76 3,21 2,52 2,34 Input kw. 1,80 1,78 1,55 1,44 1,40 1,24 1,20 ENG 7

3- TEMPERATURE BY CAPACITIES 3.4 sdh 14-065 w Cooling OUTDOOR TEMPERATURE DRY Indoor Conditions 21ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 21ºC D 15ºC W 24ºC D 17ºC W 27ºC D 19ºC W 32ºC D 23ºC W Total capacity kw 6,79 6,50 6,26 5,91 5,67 5,49 5,31 Sensitive capacity kw 5,43 5,20 5,01 4,72 4,54 4,39 4,25 Input kw. 1,54 1,76 1,98 2,21 2,43 2,65 2,87 Total capacity kw 7,44 7,11 6,86 6,47 6,21 6,01 5,82 Sensitive capacity kw 5,95 5,69 5,48 5,17 4,97 4,81 4,66 Input kw. 1,63 1,86 2,09 2,33 2,56 2,79 3,03 Total capacity kw 8,08 7,73 7,45 7,03 6,75 6,54 6,33 Sensitive capacity kw 6,47 6,19 5,96 5,62 5,40 5,23 5,06 Input kw. 1,72 1,96 2,21 2,45 2,70 2,94 3,19 Total capacity kw 9,30 8,89 8,57 8,08 7,76 7,52 7,28 Sensitive capacity kw 7,44 7,11 6,86 6,47 6,21 6,01 5,82 Input kw. 1,97 2,25 2,54 2,82 3,10 3,38 3,66 ENG HEATING Indoor Conditions 15ºC 18ºC 20ºC 22ºC 27ºC OUTDOOR CONDITIONS 24ºC D 18ºC W 12ºC D 11ºC W 7ºC D 6ºC W 4ºC D 3ºC W 0ºC D -1ºC W -5ºC D -6ºC W -7ºC D -8ºC W -15ºC D -16ºC W Capacity kw 13,64 10,92 9,10 8,19 7,73 6,82 6,37 5,91 Input kw. 4,24 3,39 2,83 2,69 2,55 2,40 2,26 1,98 Capacity kw 12,81 10,25 8,54 7,69 7,26 6,41 5,98 5,55 Input kw. 3,99 3,19 2,66 2,52 2,39 2,26 2,13 1,86 Capacity kw 11,87 9,49 7,91 7,12 6,72 5,93 5,54 5,14 Input kw. 3,69 2,95 2,46 2,34 2,21 2,09 1,97 1,72 Capacity kw 10,92 8,73 7,28 6,55 6,19 5,46 5,09 4,73 Input kw. 3,39 2,72 2,26 2,15 2,04 1,92 1,81 1,58 Capacity kw 9,49 7,59 6,33 5,70 5,38 4,75 4,43 4,11 Input kw. 2,95 2,36 1,97 1,87 1,77 1,67 1,57 1,38 8

4- WIRING DIAGRAMS wiring diagram for indoor SDH 14-025 W / SDH 14-035 W / SDH 14-050 W. wiring diagram for indoor SDH 14-065 W 9

4- WIRING DIAGRAMS wiring diagram for outdoor SDH 14-025-035 W wiring diagram for outdoor SDH 14-050 W wiring diagram for outdoor SDH 14-065 W 10

5- ERROR CODES 11

6- FLOW CHART OF DIAGNOSIS AND SOLUTIONS FOR 026-036-051 UNITS 1. After energizing, no indicator is lighted and the air conditioner can t be operated. 12

6- FLOW CHART OF DIAGNOSIS AND SOLUTIONS 2. Resetting phenomenon often occurs during operation. (That is automatically entering to the status when the power is on) The reason is that the instantaneous voltage of main chip is less than 4.5 V. Check according to the following procedure: 3. Operation lamp flashes and Timer lamp off. : 13

6- FLOW CHART OF DIAGNOSIS AND SOLUTIONS 4.Operation lamp flashes and Timer lamp on. : 5.Operation lamp off and Timer lamp flashes. : ENG 6. Operation lamp on and Timer lamp flashes. EEROM error, indoor PCB is defective. : 7. Operation lamp flashes and Timer lamp flashes. This alarm happens when the main chip can t detect zero-sign. When such failure occurs, the main control board is defective.: 14

6- FLOW CHART OF DIAGNOSIS AND SOLUTIONS FOR 065 UNITS 1. After energizing, no indicator is lighted and the air conditioner can t be operated. 15

6- FLOW CHART OF DIAGNOSIS AND SOLUTIONS 2. Resetting phenomenon often occurs during operation. (That is automatically entering to the status when the power is on) The reason is that the instantaneous voltage of main chip is less than 4.5 V. Check according to the following procedure: 3. Over current protection of the compressor occurs 4 times. : 16

6- FLOW CHART OF DIAGNOSIS AND SOLUTIONS 4. Temperature sensor error. Including the indoor room, indoor evaporator and outdooor condenser temperature sensor. 5. Outdoor unit protects. 6. EEROM error. EEROM error, indoor PCB is defective, change indoor PCB or change EEPROM if it s changeable. 7. Indoor unit communication error. 17

7- PCB EXPLANATION 7.1 Proper symbols and their meaning TA Indoor ambient temperature TE Indoor evaporator temperature TS Setting temperature through the remote controller I3sec Self-protection amp of compressor, continue three seconds until turns off the compressor. I5MIN Self-protection amp of compressor, continue five minutes until turns off the compressor. IFAN Self-protection amp of outdoor fan/indoor fans when they change from higher wind to lower wind. IRESTORE Amp self-protection return value THDEFROST High wind, defrosting temperature difference TMDEFROST Middle wind, defrosting temperature difference TLDEFROST Low wind, defrosting temperature difference TE1 Anti-cold wind, from Fan Off to Breeze temperature TE2 Anti-cold wind, from Breeze to Setting Fan Speed temperature TE3 Anti-cold wind, from Setting Fan Speed to Breeze temperature TE4 Anti-cold wind, from Breeze to Fan Off temperature TE5 Evaporator low temperature protection entering temperature TE6 Evaporator low temperature protection restoring temperature TE7 Evaporator high temperature protection, compressor off temperature TE8 Evaporator high temperature protection, fan off temperature TE9 Evaporator high temperature protection, restoring temperature TE10 Condenser high temperature protection, compressor off temperature (only for 065 unit) TE11 Condenser high temperature protection, restoring temperature (only for 065 unit) 7.2 FUNCTION Remote receiving Testing and forced running Position set for indoor unit wind vane LED displaying and alarm On or off Timer Protection for the compressor Current protection High temperature protection of indoor heat exchanger at heating mode Auto defrosting and heating recovery at heating mode Anti cold air at heating mode Anti frozen at cooling mode (only for 026-036-051 units) 18

7- PCB EXPLANATION 7.3 Protection 3 minutes delay at restart for compressor. Sensor protection at open circuit and breaking disconnection Fan Speed is out of control. When Indoor Fan Speed is too high(higher than 2100RPM)or too low(lower than 300RPM) lasting 50 seconds, the unit stops and LED displays failure information and can t returns to normal operation automatically. Cross Zero signal error warning. If there is no Cross Zero signals in 4 minutes, the unit stops and LED displays failure information and can t returns to normal operation automatically. The current protection of the compressor If compressor turns off for continuously 4 times due to current protection in 5 minutes from Compressor On, the unit stops and LED displays failure information and can t return to normal operation automatically. 7.4 Fan-only mode Fan speed is high / mid / low / Auto ENG 19

7- PCB EXPLANATION 7.5 Cooling mode The 4-way valve is closed at cooling mode. The action of the compressor and the outdoor fan:(t=indoor temperature) Auto fan at cooling mode: (4 for 065 unit) Anti-freezing control to indoor evaporator at cooling mode ( T: evaporator temp. ) Condenser high temperature protection (only for 065 unit): 20

7- PCB EXPLANATION 7.6 Dehumidifying mode The 4-way valve is off in dehumidifying mode. For 065 unit, protection is the same as cooling mode. For 026-036-051 units, Compressor and Indoor Fan actions in dehumidifying mode, as follows: Block Indoor Fan Compressor and Outdoor fan A B C LOW BREEZE LOW BREEZE LOW BREEZE ON 6 minutes OFF 4 minutes ON 5 minutes OFF 5 minutes ON 4 minutes OFF 6 minutes Repeat on and off cycle. Low room temperature protection: When room temperature decreases to below 10, compressor and outdoor fan will stop(indoor fan is Breeze). Dehumidifying operation will be resumed when room temperature restores to over 13ºC. At dehumidifying mode, the anti-freezing function of the indoor heat exchanger is the same as that of cooling mode. At dehumidifying mode, the action of fans of indoor is the same as that of air-only mode. 7.7 Heating mode Generally, the 4-way valve is open in heating mode, but it is closed in defrosting mode. 4-way valve must delay 2 minutes compared with compressor if the compressor changed into non-heating mode or turned off. 4-way valve doesn t delay in dehumidifying mode Generally, the outdoor fan is turned off with the on-off action of compressor in heating mode, except for the defrosting mode or the end of defrost Action of compressor and outdoor fan motor at heating mode: compressor must run for 7 minutes after starting and then judge temperature. Meanwhile other protections are still valid. ENG * This parameter can be changed from 0 to 3 21

7- PCB EXPLANATION Indoor Fan actions at heating mode Indoor Fan can be set at HIGH/MID/LOW/AUTO by using a remote controller, but Anti-cold wind function prevails. Anti-cold wind control function at heating mode (T=indoor exchanger temp.) Auto wind at heating mode (T=indoor temp.) Indoor evaporator high-temperature protection at heating mode (T=indoor exchanger temp.) 22

7- PCB EXPLANATION The louver opens to Standard Angle ANGLHEAT when power is on for the first time. 7.8 Defrosting mode FOR 026-036-051 UNITS: Defrosting condition: Defrosting starts when either of the following and : A and B are satisfied: A: The compressor keeps running for 40 minutes or more. B: The temperature difference of evaporator and room temperature meets one of the following: Calculate from the end of latest defrost, evaporator high temp. Protection only closes outdoor fan with the compressor still running. Add up to 90 minutes. Defrosting time: At condition, If item B is satisfied before item A, it would be regarded as severe frosting and the defrosting 1time is 10 minutes. If item B is satisfied after item A, the defrosting time is 7.5minutes. At condition, the defrosting time is 10 minutes.2 After three times continuous 7.5-minute defrost, the fourth defrost time should be 10 minutes. The circulation is as following: Ending condition of defrosting If one of following conditions is satisfied, end the defrost and turn into heating mode: ENG A. The defrost time has reached to 7.5 or 10 minutes. B. The compressor current has reached to IDEFROST or above, IDEROST differs in different models 23

7- PCB EXPLANATION FOR 065 UNIT ONLY: Defrosting condition: Defrosting starts when either of the following: The compressor works under the condition that T3 lower than 0 C add up to more than 40 minutes, and under the condition that T3 is lower than -3 C consecutively reaches 3 minutes. Calculate from the end of latest defrost, that evaporator high temperature protection only closes outdoor fan with the compressor still running add up to 90 minutes Conditions of defrost ending: Defrosting ends when either of the following: The time gets to 10 minutes. T3>20 C. The circulation is as following: Defrosting Actions (valid for all units) 7.9 Auto mode The air conditioner automatically selects one of the following operation modes: cooling, heating or fan only according to the temperature difference between room temperature (TA) and set temperature (TS). ENG The indoor fan blows automatically in corresponding selected mode The motion of indoor fan s blade should accord with the selected operation mode One mode should be carried out for at least 15 minutes once selected. If the compressor cannot start for 15 minutes, reselect the operation mode according to the room temp. and set temp., or reselect when the set temp. varies. 24

7- PCB EXPLANATION 7.10 Force cooling function Select forced cooling function with the forced cooling button or the switch The compressor is unconditionally turned on, after 30 minutes cooling operation whose fan mode is set as low, the A/C operates at the DRY mode with a set temp. of 24ºC All protections of remote control cooling are available at forced cooling operation Forced Auto function Select forced auto function with the forced auto button or the switch. In forced auto status the A/C operates at remote control mode with a set temp. of 24ºC 7.11 Sleep mode The sleep function is available at cooling, heating or auto mode Cooling: The set temperature rise 1 per hour. Two hours later, the set temperature will maintain as a constant and the fan speed is kept at low speed. The total time is 7 hours, after 7 hours the unit stops. Heating: The set temperature decrease 1ºC per hour. Two hours later, the set temperature will maintain as a constant and the air circulation is kept at low speed (Anti-cold function takes precedence over all). The total time is 7 hours, after 7 hours the unit stops. Auto: After an hour running under economic mode, the set temp will rise 1ºC,if it is under cooling mode; the set temp will decrease 1ºC,if it is under heating mode; the set temp will be changeless, if it is under fan -only mode; the condition will be the same after the air conditioner running under economic mode after 2 hours, and during the next time the set temp do not change. The total time is 7 hours, after 7 hours the unit stops. 7.12 auto restart function Auto restart function: In case of a sudden power failure, this function automatically sets the unit to previous settings before the power failure when power returns. 7.13 turbo mode Turbo mode: In cooling mode, when pressing the turbo button on the remote controller, the unit will enter turbo mode with ultra-high speed and reach the set temperature more quickly. After running 20 minutes in turbo mode, the indoor fan will automatically recover the preset speed. ENG 25

NOTES 26

NOTES 27

Saunier Duval reserves the right to modify specifications without prior notice. Spain: Saunier Duval Clima S.A. Polígono Ugaldeguren 3 Parcela 22 48170 Zamudio (Bizkaia) Tel: +34 94 489 62 00 Fax: +34 94 489 62 53 www.saunierduval.es info@saunierduval.es SDH14-W-TD 02/2010