Efficient energy recovery in AHU. DOHA, Qatar Timo Schreck Enventus AB, Sweden

Similar documents
FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

Standards and Guidelines. Presented by: Aric Murray December 12, 2014

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

TDSHS Air Change Requirements and the Basics of Psychrometrics. Presented by: Aric Murray December 06, 2013

» WITH REGASORP ROTARY HEAT EXCHANGER

To Keep Docs Cool, Dry and Happy

Section 4 of 6 DOAS Core Technologies

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

Basic Principals of Air conditioning By Dr. Esam Mejbil Abed

ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes

Chapter 14, Problem 27.

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Air is our element. energy recovery our passion. Rotors overview. Quick guide GOST VDI 6022

YMA Air Handling Units

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

Munters Heat Exchangers

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

H O B O K E N R E S I D E N T I A L

Humidity Control & Psychrometrics


Pressure Enthalpy Charts

AHRI 920 & ASHRAE 90.1

Humidity Control Design Tips. R. Mark Nunnelly, PE, CxA, LEED AP President

Desiccant Cooling Analysis Simulation software, energy, cost and environmental analysis of desiccant cooling system

Designing Energy Efficient Outdoor Air Systems

Temperature. In the HVAC area, we talk about two kinds of temperatures.

ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit

100% Outdoor Air Dehumidification Methods

Psychrometrics. Outline. Psychrometrics. What is psychrometrics? Psychrometrics in daily life and food industry Psychrometric chart

Rotors overview. Quick guide GOST VDI 6022

Heat pump and energy recovery systems

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

Next Generation Passivhaus Archives

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Trane CDQ Desiccant Dehumidification

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

The New Sorption Rotary Heat Exchanger

Energy Saving of Inverter Air Conditioner and R32 Refrigerant DAIKIN VIETNAM. 13 th May 2017

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Dehumidifying with Dedicated Outdoor Air

Principles of Active Desiccant Operation. Presented by Tom Peterson, CEO and Founder. Climate by Design International

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Desiccant Cooling with Solar Energy

AiCARR Journal. 2015, 343, 52-58bis. Research paper ABSTRACT

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Why should you opt for ENTHALPY. Wheels for your. AHUs. ERVs. (Energy Recovery Ventilators) (Air Handling Units) from

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Achieving Dry Outside Air in an Energy-Efficient Manner

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

Optimizing the use of Chilled Beams for health and comfort GUNNAR SVENSSON

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

Adding More Fan Power Can Be a Good Thing

A New Dedicated Outdoor Air System with Exhaust Air heat recovery

Chapter 8 Balances on Nonreactive Processes PSYCHROMETRIC CHART

Heat Recovery Units. Heat Recovery 1

The Clivet Enhanced Hydronic System March 20th Inserire immagine

HCU Systems for Industrial Applications. Rob Smith National Accounts Manager March 7, 2011

Recent Advances in Energy, Environment and Economic Development

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

High Efficiency Dehumidification System (HEDS)

Air Conditioning for and-humid Climates:

In Search of Indoor Comfort

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Dehumidification System Enhancements

THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

R07. Answer any FIVE Questions All Questions carry equal marks *****

A/C Cooling Load calculation and measurement

Existing Mechanical System Operation

Rotary heat exchangers Product catalogue

AHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU

recooler HP EQKR HEAT PUMP

Psychrometric Engineering Applications

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

CONDENSATION/HUMIDITY PROBLEMS IN BREWERIES

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

Summary Comparison of Simulation Program Features

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

Evaporative-Cooled vs. Air-Cooled Chillers: Kirtland AFB Case Study

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

Dedicated Outdoor Air Systems: AHRI 920, ISMRE & ASHRAE 90.1

Hawaii Energy and Environmental Technologies (HEET) Initiative

CHAPTER 4. HVAC DELIVERY SYSTEMS

Daikin Blueprint: Delivering Hot Water with a Chiller

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

Refrigeration Basics from a Brewery Perspective

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

LATENT COOLING LEAD. Kecha Thirakomen EEC Engineering Network

Rotary heat exchangers

2. CURRICULUM. Sl. No.

Available online at ScienceDirect. Energy Procedia 52 (2014 ) Vishal Vadabhat, Rangan Banerjee

Direct Digital Temperature, Humidity, and Condensate Control for a Dedicated Outdoor Air-Ceiling Radiant Cooling Panel System

Fans Air handling units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Air Humidifiers For DV Air Handling Units

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Transcription:

Efficient energy recovery in AHU DOHA, Qatar 11.04.2010 Timo Schreck Enventus AB, Sweden

Main principles for cooling and dehumidification process in AHU 1. With cooling coil and reheater 2. Energy recovery with sensible or sorption rotor 60 kj/kg Enthalpy Rel. humidity 100% 80% 60% 50% Summer outdoor design 46.1 C, 31% 1 40% 30% Water 24 g/kg 22 g/kg 20 g/kg 18 g/kg 16 g/kg 1.20 kg/m3 20% 14 g/kg 1. With cooling coil and reheater 2. + With horse shoe heat pipe 2 Exhaust air 24.0 C 50% Incoming Fresh Air 20.6 C, 61% 15% 10% 12 g/kg 10 g/kg 8 g/kg 6 g/kg 5% 4 g/kg 3. With double wheel system and cooling coil 10 15 20 25 30 1.15 kg/m3 35 40 45 1.10 kg/m3 2 g/kg -0 g/kg Temperature Carrier psychrometric chart for air humid - Pressure 1.013 bar (0.000 m / 20.000 C / 50.000 % rh)

CASE STUDY Location: Dubai / Doha Summer out door 46.1 C, Rh 31%, 19.9 g/kg Inlet fresh air 20.6 C, Rh 61%, 9.2 g/kg Exhaust air 24.0 C Rh 50%, 9.2 g/kg Calculation done for 1m 3 /s, 3600 m 3 /h Temp / humidity efficiency of HR units 65-70% Exhaust air 90% of supply air COP of cooling units 3 Cooling capacity cost 300-400 /kw, 300 /kw used Electric capacity cost 800-1000 /kw, 800 /kw used (price of power plant, actual for peak load case)

The process Enthalpy Rel. humidity 100% 80% 60% 50% Summer outdoor design 46.1 C, 31% 1 40% 30% Water 24 g/kg 22 g/kg 20 g/kg 60 kj/kg 18 g/kg 16 g/kg 1.20 kg/m3 20% 14 g/kg 12 g/kg 2 Exhaust air 24.0 C 50% Incoming Fresh Air 20.6 C, 61% 15% 10% 10 g/kg 8 g/kg 6 g/kg 5% 4 g/kg Process load: 64 kw/m 3 /s 1.15 kg/m3 1.10 kg/m3 2 g/kg -0 g/kg 10 15 20 25 30 35 40 45 Temperature Carrier psychrometric chart for air humid - Pressure 1.013 bar (0.000 m / 20.000 C / 50.000 % rh)

The challenge Investor: - Minimum investments - Energy efficient solution Society: -Sustainable development - Green building, LEEDS etc. - Regulations Engineer: - Minimum service - Minimum amount of partners - No problems - Fast to design - Easy to commission - Peace of mind - Good engineering work

No energy recovery

Basic traditional process w/o recovery Enthalpy Rel. humidity 100% 80% 60% 50% Summer outdoor design 46.1 C, 31% 1 40% 30% Water 24 g/kg 22 g/kg 20 g/kg 60 kj/kg Cooling down to 12.8 C Dehumidification -10.2 g/kg 1.20 kg/m3 20% 18 g/kg 16 g/kg 14 g/kg 12 g/kg 15% 10 g/kg Reheating to 20.6 C 2 Incoming Fresh Air 20.6 C, 61% 10% 8 g/kg 6 g/kg 10 15 20 25 Cooling 75 kw/m 3 /s 30 Carrier psychrometric chart for air humid - Pressure 1.013 bar (0.000 m / 20.000 C / 50.000 % rh) 1.15 kg/m3 35 40 45 1.10 kg/m3 5% 4 g/kg 2 g/kg equals 25 kw/m 3 /s electric power -0 g/kg Reheating 10 kw/m 3 /s Temperature

Without energy recovery Pros Low initial cost in AHU Cons Very high running cost Higher initial cost in cooling, electric installation etc. Summary Should be avoided as total economically bad solution Not sustainable design

Energy recovery with sensible wheel

With sensible wheel: Enthalpy Rel. humidity 100% Cool recovery down to 30.9 C no dehumidification 3 80% 60% 50% Summer outdoor design 46.1 C, 31% 1 40% 30% Water 24 g/kg 22 g/kg 20 g/kg 60 kj/kg 18 g/kg cooling down to 12.8 C 1.20 kg/m3 20% 16 g/kg 14 g/kg 4 Exhaust air 24.0 C 50% Incoming Fresh Air 20.6 C, 61% 2 10% 15% 12 g/kg 10 g/kg 8 g/kg 6 g/kg 10 15 20 25 Cool recovery 19 kw/m 3 /s Cooling 55 kw/m 3 /s 30 1.15 kg/m3 equals 18kW/m 3 /s electric power 35 Reheating 10 kw/m 3 /s Carrier psychrometric chart for air humid - Pressure 1.013 bar (0.000 m / 20.000 C / 50.000 % rh) 40 45 1.10 kg/m3 5% 4 g/kg 2 g/kg -0 g/kg Temperature

Sensible wheel Pros 25% of cooling load is recovered Smaller cooling unit and cooling coil Cons No humidity recovered Electric heating still needed Could be much better with little extra investment Summary Solution that should be avoided if dehumidification needed First step towards energy recovery

Sorption / Total Energy wheel

With sorption/total energy wheel 60 kj/kg 1.20 kg/m3 Cooling down to 12.8 C 4 Enthalpy Rel. humidity 100% 80% Cool recovery down to 31.2 C dehumidification -7.4 g/kg 2 Incoming Fresh Air 20.6 C, 61% 3 60% 50% Summer outdoor design 46.1 C, 31% Exhaust air 24.0 C 50% 1 40% 10% 15% 20% 30% Water 24 g/kg 22 g/kg 20 g/kg 18 g/kg 16 g/kg 14 g/kg 12 g/kg 10 g/kg 8 g/kg 6 g/kg 10 15 20 Cool recovery 41 kw/m 3 /s Cooling 35 kw/m 3 /s 25 30 1.15 kg/m3 equals 12 kw/m 3 /s electric power Carrier psychrometric chart for air humid - Pressure 1.013 bar (0.000 m / 20.000 C / 50.000 % rh) 35 Reheating 10 kw/m 3 /s 40 45 1.10 kg/m3 5% 4 g/kg 2 g/kg -0 g/kg Temperature

Sorption/total Energy wheel Pros 55% of cooling load, 63% of latent load is recovered Smaller cooling coil Cons Still more to recover Electric heating still needed 10 kw/m 3 /s Summary A good established solution towards good energy recovery

Sorption wheel + horse shoe heat pipe

With Sorption wheel +heat pipe 60 kj/kg Enthalpy 1.18 kg/m3 Rel. humidity 100% 80% 70% 60% 50% Summer outdoor design 46.1 C, 31% 1 40% 30% Water 24 g/kg 22 g/kg 20 g/kg 18 g/kg 1.22 kg/m3 Cooling down to 12.8 C 1.20 kg/m3 5 6 Heat pipe heating up to 18.1 Heat pipe cooling down 25.2 4 2 3 Exhaust air 24.0 C 50% Incoming Fresh Air 20.6 C, 61% Cool recovery down to 31.2 C dehumidification -7.4 g/kg 20% 10% 15% 16 g/kg 14 g/kg 12 g/kg 10 g/kg 8 g/kg 6 g/kg 5% 4 g/kg 10 12 14 16 18 20 22 24 26 28 30 1.16 kg/m3 32 34 1.14 kg/m3 36 38 40 1.12 kg/m3 Cool recovery 49 kw/m 3 /s Cooling 27 kw/m 3 /s Carrier psychrometric chart for air humid - Pressure 1.013 bar (0.000 m / 20.000 C / 50.000 % rh) 42 44 46 1.10 kg/m3 48 equals 9 kw/m 3 /s electricity Reheating 3 (7)kW/m 3 /s 2 g/kg -0 g/kg Temperature

Sorption wheel + heat pipe Pros 65% of cooling load, 63% latent load recovered. Reduced electric heating capacity Smaller cooling coil Cons Still electric reheating needed, horse shoe heat pipe doesn t heat in winter Freon installation with leakage risk What happens in long run? Summary Good step into right direction Still electric heating needed in winter Freon coils are doubtful for green design

Double wheel concept

Double wheel concept 60 kj/kg Enthalpy 1.18 kg/m3 Rel. humidity 100% 80% 70% 60% 50% Summer outdoor design 46.1 C, 31% 3 40% 30% Water 24 g/kg 22 g/kg 20 g/kg 18 g/kg Cool recovery down to 23.9 C dehumidification -8.3 g/kg 1.20 kg/m3 20% 16 g/kg 14 g/kg 1.22 kg/m3 Cooling down to 12.8 C Reheat recovery to 20.6 C 1 4 2 1 Exhaust air 24.0 C 50% Incoming Fresh Air 20.6 C, 61% 10 12 14 16 18 20 22 24 26 28 1.16 kg/m3 30 Carrier psychrometric chart for air humid - Pressure 1.013 bar (0.000 m / 20.000 C / 50.000 % rh) 32 34 1.14 kg/m3 1.12 kg/m3 36 38 40 42 44 46 1.10 kg/m3 48 10% 15% 5% 12 g/kg 10 g/kg 8 g/kg 6 g/kg Cool recovery 53 kw/m 3 /s Cooling 22 kw/m 3 /s equals 7 kw/m 3 /s electricity Reheating 0 kw/m 3 /s 4 g/kg 2 g/kg -0 g/kg Temperature

Double wheel concept Pros 71% of cooling load, 77% latent load recovered No electric heating Even smaller cooling coil Cons Some increase in AHU costs(in total installation cost savings) Summary Perfect energy saving concept Should be used when reheating is needed due to dehumidification Heat and cool recovery in one

Comparison of different solutions per m 3 /s System w/o energy recovery Sensible wheel Sorption/to tal energy wheel Sorption wheel + heat pipe Double wheel Cooling load kw/m 3 /s % Heating load kw/m 3 /s Other extra power: additional fan, drive motor Total electric power load kw/m 3 /s COP = 3 % Total cost of the loads Electric 800 /kw Cooling 300 /kw 75 0% 10 0 35 0% 50500 0% 55-27% 10 0.2 29-17% 39400-22% 35-53% 10 0.3 22-37% 28100-44% 27-64% 3(7) 0.5 16-54% 21300-58% 22-71% 0 0.5 8-77% 12800-75% %

Summary of double wheel concept Excellent concept from energy saving perspective Sustainable green design Major savings in investments of Cooling capacity, chillers, cooling towers etc. No electric heating Electric installation no switches for electric hester Electric capacity fees Cooling piping installations. Major Energy savigns In all conditions and seasons When reheating is required after dehumidification

Thank you for your interest! Any Questions?

Design Dimensioning: 1. Sensible wheel 1. Exhaust air conditions 2. Air after cooling coil 3. Expected fresh air temperature 4. About 70% temperature efficiency. 2. Sorption / Total Wheel 1. Out door air 2. Exhaust air after Sensible wheel 3. Max capacity with 1.7 or 2.0 mm well height 70-85% temperature and humidity efficiency 3. Cooling coil 1. Supply air after Sorption /total wheel 2. Supply air to expected dew point Controls: 1. Sensible rotor. 1. Max capacity or temperature controller rotation speed 2. Sorption/ Total energy rotor 1. Max recovery capacity all the time. Can be constant speed. 10 12 60 kj/kg 1.22 kg/m3 14 3 1 16 1.20 kg/m3 2 18 20 Enthalpy 1.18 kg/m3 1 22 4 1 24 Rel. humidity 26 28 1.16 kg/m3 30 100% 32 34 80% Exhaust air 24.0 C 50% Incoming Fresh Air 20.6 C, 61% 1.14 kg/m3 36 70% 38 60% 40 1.12 kg/m3 42 50% Summer outdoor design 46.1 C, 31% Carrier psychrometric chart for air humid - Pressure 1.013 bar (0.000 m / 20.000 C / 50.000 % rh) 2 44 46 3 1.10 kg/m3 40% 48 5% 10% 15% 20% 30% Water 24 g/kg 22 g/kg 20 g/kg 18 g/kg 16 g/kg 14 g/kg 12 g/kg 10 g/kg 8 g/kg 6 g/kg 4 g/kg 2 g/kg -0 g/kg Temperature