Service Manual. Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM

Similar documents
Ceiling & Floor type Unit

1. Features Specification Dimensions Refrigeration cycle diagram Operation limits

Floor-Standing Type(E Series)

High static Pressure Duct Type Air-conditioner

Four-way Cassette Type

Multi Inverter Air Conditioning Condensing Units - Summary

MANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30

Technical & service manual 2005

Window Y9USC/E 09 / 12 / 18 B5R

Blanc ON-OFF Series. Service Manual 2016

Corona Plus varmepumper

Cover. Service Manual PAC9037 PAC12037 PAC13037 PAC18037

Installation, Operation & Maintenance

MODEL: CCT 301 INV CCT 501 INV CCT 70 INV-S CCT 100 INV-S CCT 140 INV-S CCT 170 INV-S

Floor-Standing Type(S2 Series)

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

WALL MOUNTED UNITS SDH W SDH W SDH W SDH W

TECHNICAL & SERVICE MANUAL

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

PRODIGY 3D Inverter. Technical Manual

[U] Serie MHB / MHA Manual de Ingeniería

[U] Serie MOV. Manual de Ingeniería

Service Manual. Room Air Conditioner Split Wall-Mounted Type. Applies to: HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1

Cassette SERVICE MANUAL. YKHC 18 to 48 YKHC 18 YKHC 24 YKHC 30 YKHC 36 YKHC 48 SM-YKHC-18-48GB 03-07

Service manual. MIV V4+ Mini

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

SERVICE MANUAL UNI ON/OFF ASC-60A

Mobile Type Air Conditioner

KSIM20912-H216 KSIM30912-H216 KSIM40912-H216

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall SERVICE MANUAL. TLCA-TLHA 07 to 18 FSAAAR TLCA-07 / TLHA-07 TLCA-09 / TLHA-09 TLCA-12 / TLHA-12 TLCA-18 / TLHA-18 SM-TLCA-TLHA-07-18GB 06-08

Content Precaution...2 Function...3 Dimension...5 Refrigerant cycle diagram...7 Operation limits...8 Wiring diagram...9 Installation details...

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

SERVICE MANUAL INVEST HEAT PUMP DC INVERTER SPLIT WALL-MOUNTED TYPE MSC-24/QD FP MSH-24/QD FP

R410 a. Air Conditioners. Residential and commercial. R410 a

Submittal Data Sheet

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.

VMI-1102-A SERVICE MANUAL AIRCONDITIONER DC INVERTER MULTI TYPE MSV1I-09HRDN1-M TAS-09MVHN TAS-12MVHN INDOOR VERTU DC INVERTER MULTI SERIES

SERVICE MANUAL CONDENSING UNIT ASE-18AH, ASE-24AH, ASE-36AH, ASE-48AH, ASE-60AH

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

AIR HANDLER UNIT R410A 60HZ ON-OFF CONTROL

CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS

Product Data FEATURES AND BENEFITS. QHF 50Hz Heat Pump Inverter Single Phase 2.5kW to 8.0kW

The latest innovation in cool 7 YEAR 1 YEAR WARRANTY ON PARTS WARRANTY ON COMPRESSORS

SERVICE MANUAL SPLIT WALL-MOUNTED TYPE MODELS MWCOHC30S/MRCOHC30AS MWCOHC36S/MRCOHC36AS

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Operating Functions Temperature Parameters

SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Westinghouse. Split System Inverter Series. Service Manual

NORTH AMERICAN HVAC PRODUCTS LTD. Tel: Fax: DC Inverter Single Zone Split Wall-Mounted Type

Service Manual AIR CONDITIONER

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

COLDWAVE. Portable Air Conditioner. Model MPPD-12CRN BTU/h 110V/1Ph/60Hz R410A

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Mono DC. VERTU MONO Split DC Inverter Air Conditioner SERVICE MANUAL MSV1-18HRDN1-MQ0W. Revision A: , Content updated.

Hi - Wall Split Systems 12K - 18K - 24K

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

SPLIT TYPE AIR CONDITIONER WAS-09HSTD WINTAIR

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

NORTH AMERICAN HVAC PRODUCTS LTD 3208 BETA AVE, BURNABY BC V5G 4K4 CSNA-1305-A SERVICE MANUAL AIR CONDITIONER SPLIT WALL-MOUNTED TYPE.

KSIN INVERTER SERIES Service Manual 2013

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

Technical Guide. Split Air-Conditioners Equipment Residential COS Series

6. DUCT TYPE AR 60FUAK, AR 60UUAK

CEILING CONCEALED DUCT R410A 60HZ 3D INVERTER CONTROL 2017 TECHNICAL MANUAL

Service Manual. Air Conditional

SUPER DC INVERTER MULTI TYPE INSTRUKCJA SERWISOWA

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

FLUYE CON TU ESTILO DE VIDA

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

DESIGN & TECHNICAL MANUAL

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type Version. R410A50Hz Universal Outdoor Series Technical Manual LCAC/1.

SEER 15 DC INVERTER SERIES

AIR CONDITIONERS SPLIT TROPICAL RANGE. FLAT SPLIT - Heat & Cool T1 R410a AMD K BTU EAN: AMD K BTU EAN:

SERVICE MANUAL Room Air Conditioner DC Inverter Multi Split Outdoor units

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

FROZEN SERIE SERVICE MANUAL. DC Inverter R32. Sistemi per la climatizzazione

F SERIES ON-OFF SERIES. Service Manual 2016

NORTH AMERICAN HVAC PRODUCTS LTD. Tel: Fax: DC Inverter Single Zone Split Wall-Mounted Type

Multi zone. MULTI OUTDOOR UNITsS. CONDENsSING UNITsS. Revision V1.0: Table of Contents

50A KP 70A KP 90A KP 120A KP 150A KP 210A

R410A50Hz Universal Outdoor Series Technical Manual

Light Commercial SUPER INVERTER SERIES MULTI TYPE

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

PRODUCT LINE-UP Residential & Light Commercial air conditioners

American Brand with Global Reach. Heat Pump Decorative Wall Mount Split Unit

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

Mini Split Air Conditioners and Heat Pump

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

Room Air Conditioner CONTENTS CS-E9BKP CU-E9BKP5 CS-E12BKP CU-E12BKP5. Order No: MAC C2

Calor Top 300D(S) Air-source Heat Pump Water Heater

YC ON-OFF SERIES. Service Manual

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

Transcription:

Service Manual Multi Split Type Heat Pump Air Conditioners Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM

CONTENT 1. Product features 2. Specification 3. Dimensions 4. Refrigeration cycle diagram 5. Operation limits 6. Indoor unit combination 7. Wiring diagram 8. Electric control functions 9. Troubleshooting 10. Exploded view Annex 1 Characteristic of temp. sensor Annex 2 Reference data

1 Product Features 1.1 Powerful at cooling/heating. 1.2 Low voltage start-up function. 1.3 Anti-icing function at cooling mode. 1.4 Anti-cold air function at heating mode. 1.5 Auto-defrosting. 1.6 Outdoor electric current protection 1.7 Temperature protection of the outdoor compressor top. 1.8 Error self diagnosis function. 1.9 Free connection between indoor and outdoor unit -1-

2 Specification 2.1 Alfa series Power supply Cooling Heating Indoor fan motor Indoor coil Capacity Input Model Rated current Capacity Input Rated current Model Brand Input Capacitor Indoor air flow (Hi/Mi/Lo) Speed(hi/mi/lo) a.number of rows b.tube pitch(a)x row pitch(b) c.fin spacing d.fin type (code) Indoor noise level (Hi/Mi/Lo) Indoor unit e.tube outside dia.and type f.coil length x height x width g.number of circuits Dimension (W*H*D) Ph-V-Hz Btu/h W A Btu/h W A W uf r/min mm mm mm mm m3/h db(a) mm Packing (W*H*D) mm Liquid side/ Gas side Net/Gross weight mm kg HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_ MSHI-09HRIN1 HOS-21U11IM MSHI-12HRIN1 1Ph,220-240V~,50Hz 1Ph,220-240V~,50Hz 9000 12000 38 42 0.16 0.2 11000 14000 39.5 42 0.16 0.2 RPG13H RPG20D WEILING WEILING 36 38 1.2 1.5 1200/950/850 1250/1000/800 2 2 21 13.37 21 13.37 1.3 1.3 Hydrophilic aluminium Hydrophilic aluminium φ7, innergroove tube φ7, innergroove tube 578X252X26.74 635 315 27.34 2 2 500/460/410 680/520/420 36/34/32 39/33/28 750*250*205 815*280*215 830*285*336 915*290*360 Ф6.35/Ф9.53 Ф6.35/Ф12.7 8.5/10 10/12-2-

2.2 Outdoor unit Outdoor Model HOS-18U2IM M2OA-18HRDN1 AND HOS-21U11IM Indoor Units Combination Single Double Power supply Ph-V-Hz 1Ph,220-240V~,50Hz Capacity Btu/h 700012000 18000 Capacity W 5275 Cooling Input W 1000~1300 1644 Rated current A 4.6~6.0 8.5 EER Btu/w.h 10.95 EER w/w 3.21 Capacity Btu/h 10000~14000 21000 Capacity W 6155 Heating Input W 1150~1450 1866 Rated current A 5.3~6.7 9.0 EER Btu/w.h 11.2 EER w/w 3.30 Energy Classification A Max. input consumption W 3100 Max. current A 16 Compressor Model JU1015D1 Type Rotary inverter Brand HITACH Capacity Btu/h 16000(60Hz) Input W 1650 Rated current(rla) A 9.7 Locked rotor Amp(LRA) A 28 Thermal protector Internal Refrigerant oil ml HAF68D1 480 ml Model YDK53-6M Brand Welling Outdoor fan motor Input W 148 Capacitor uf 3.0 Speed r/min 775 a.number of rows 1.5 b.tube pitch(a)x row pitch(b) mm 25.4 22 c.fin spacing mm 1.7 Outdoor coil d.fin type (code) Hydrophilic aluminium e.tube outside dia.and type mm φ9.53 innergroove trube f.coil length x height x width mm 776 660 22 g.number of circuits 2 Outdoor air flow m3/h 2500 Outdoor noise level db(a) 55-3-

Dimension(W*H*D) mm 845X695X335 Outdoor unit Packing (W*H*D) mm 975X772X405 Net/Gross weight Kg 68/72 Refrigerant type R410A g 2150 Design pressure(hi/lo) MPa 4.2/2.5 Liquid side/ Gas side mm(inch) Ф6.35/Ф9.53 Ф6.35/Ф9.53 Transfer Connector(9.53 mm(inch) 2 12.7) Refrigerant piping Max. refrigerant pipe length m 15 15 Max. difference in level m 10 10 Connection wiring Plug type Thermostat type Electronic control Operation temp 17-30 Ambient temp 17~43(cooling); -7~21(heating) Qty per 20 /40 /40'HQ set / / / Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27 CDB, 19 CWB; Outdoor temp: 35 CDB; Equivalent ref. Piping: 8m(horizontal) 2. Nominal heating capacities are based on the following conditions: Indoor temp: 20 CDB; Outdoor temp: 7 CDB, 6 CWB; Equivalent ref. Piping: 8m(horizontal) 3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room. -4-

3 Dimensions 3.1 Alfa Series a) Indoor unit 7/9K b) Indoor Unit 12K -5-

3.2 Outdoor unit -6-

4 Refrigeration Cycle Diagram 4.2 Refrigeration circuit drawing of inverter binary type outdoor unit heat exchanger filter capillary capillary up part down part condenser high-pressure switch 1 oil separator discharge sensor filter inverter compressor capillary low-pressure switch 2 4-way valve low-pressure oil tank heat exchanger filter 5 Operation Limits Cooling mode Heating mode Dry mode Indoor temperature 1732 Outdoor temperature 1050 Indoor temperature <=30 Outdoor temperature -1533 Indoor temperature 1032 Outdoor temperature 050 6. Indoor units combination 6.1 Indoor unit combination for M2OA-18HRDN1 HOS-18U2IM AND HOS-21U11IM One unit Two unit 7 7+7 9+9 9 7+9 9+12 12 7+12 Instruction: The total indoor units nominal capacity should not exceed 5.8kw for M2OA-18HRDN1; -7-

7. Wiring Diagram 7.1 Indoor unit (7k/9k/12k) -8-

7.2 Outdoor unit M2OA-18HRDN1 HOS-18U2IM AND HOS-21U11IM -9-

8 Electronic control function 8.1 Electric Control working environment. 8.1.1 Input voltage: 175~253V. 8.1.2 Input power frequency:50hz. 8.1.3 Indoor fan normal working amp. is less than 1A. 8.1.4 Outdoor fan. Normal working amp. is less than 1.5A. 8.1.5 Four-way valve normal working amp. is less than 1A. 8.1.6 Swing motor: DC12V. 8.2 Indoor unit s display board Infrared Signal Receiver 1 2 3 4 5 6 8.2.1 AUTO indicator This indicator illuminates when the air conditioner is in AUTO operation. 8.2.2 TIMER indicator This indicator illuminates when TIMER is set ON/OFF. 8.2.3 PRE.-DEF. Indicator (For Cooling & Heating models only) This indicator illuminates when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating mode. 8.2.4 TEMPERATURE indicator a) Usually it displays the temperature settings. When change the setting temperature, this indicator begins to flash, and stops 20 seconds later. b) It displays the room temperature when the air conditioner is in FAN only operation. c) When the unit stops operation, it returns to original factory settings. d) Displays the malfunction code or protection code. 8.2.5 OPERATION indicator This indicator flashes after power is on and illuminates when the unit is in operation. 8.2.6 SLEEP indicator This indicator appears when the unit is in Energy-saving operation. 8.3 Digital display in outdoor PCB There is a digital display tube in outdoor PCB. 8.3.1 Digital display tube display function In standby, The LED displays, In compressor operation, the LED display the frequency, In defrosting mode, The LED displays df -10-

In compressor pre-heating, The LED displays 1 1 In protection or malfunction, the LEC displays error code or protection code. 8.4 Outdoor unit point check function There is a check switch in outdoor PCB. Push the switch SW1 to check the states of unit when the unit is running. The digital display tube will display the follow procedure when push SW1 each time: Frequency of compressor Running mode Capacity demand Number of indoor unit Outdoor temp. outdoor pipe temp. current of outdoor unit No. 1 opening degree of electronic expansion valve No. 2 opening degree of electronic expansion valve No. 3 opening degree of electronic expansion valve Frequency of compressor 8.4.1 Frequency of compressor: Display 30 30 -- Stand by 60 60 Frequency of compressor (Hz) 8.4.2 Running mode: Display Corresponding mode 0 Off 1 Cooling mode 2 Heating mode 8.4.3 Capacity demand: Cooling mode Capacity 2000-2500 2000-2500 3000-3800 4500-5000 5000-5500 5500-6100 6100-7000 7000-7500 7500-8000 7500-8000 Correspon ding Code 1 2 3 4 5 6 7 8 9 >=10 Heating mode Capacity 2000-2500 2000-2500 3000-3800 4500-5000 5500-6100 6100-7000 6100-7000 7000-7500 7500-8000 8000-8900 Correspond 1 2 3 4 5 6 7 8 9-10 >=11 ing Code Note: The capacity is just for reference. 8.4.4Number of indoor unit Display Number of indoor unit 1 1 2 2 3 3-11-

8.4.5Outdoor ambient temp: Display Corresponding temp. Display Corresponding Corresponding Display temp. temp. 15-7.5 50 10 80 25 16-7 51 10.5 81 25.5 17-6.5 52 11 82 26 18-6 53 11.5 83 26.5 19-5.5 53 11.5 84 27 20-5 54 12 85 27.5 21-4.5 55 12.5 86 28 22-4 56 13 87 28.5 23-3.5 57 13.5 88 29 24-3 58 14 89 29.5 26-2 59 14.5 90 30 27-1.5 60 15 91 30.5 28-1 61 15.5 92 31 29-0.5 62 16 93 31.5 30 0 63 16.5 93 31.5 31 0.5 63 16.5 94 32 32 1 64 17 95 32.5 33 1.5 65 17.5 96 33 34 2 65 17.5 97 33.5 35 2.5 66 18 98 34 36 3 67 18.5 99 34.5 37 3.5 68 19 10. 35~40 38 4 69 19.5 11. 40~45 39 4.5 70 20 12. 45~50 40 5 71 20.5 13. 50~55 41 5.5 72 21 14. 55~60 42 6 73 21.5 15. 60~65 43 6.5 74 22 16. 65~70 44 7 75 22.5 45 7.5 75 22.5 46 8 76 23 47 8.5 77 23.5 48 9 78 24 49 9.5 79 24.5 8.4.6 Outdoor pipe temp. Refers to 8.3.5-12-

8.4.7Current of outdoor unit Display Corresponding mode 44 6.0 A 46 6.2 A 54 7.4 A 55 7.6 A 58 7.6 A 62 8.0 A 66 8.6 A 67 8.8 A 68 9.0 A 70 9.2 A 72 9.5 A 76 10.0 A 78 10.2 A 80 10.4 A 82 10.6 A 84 11.0 A 88 11.6 A 92 12.0 A 94 12.2 A 8.4.8 No. 1 opening degree of electronic expansion valve: Opening degree equals the display data times 8 8.4.9No. 2 opening degree of electronic expansion valve: Opening degree equals the display data times 8 8.4.10No. 3 opening degree of electronic expansion valve: Opening degree equals the display data times 8 8.5 Protection 8.5.1 3 minutes delay at restart for compressor. 8.5.2 Discharge temperature protection of compressor, compressor stops when the temp. of discharge is more than 115 and last out 5 s. compressor runs when the temp. of discharge is less than 90. 8.5.3 Temperature protection of compressor top, compressor stops when the temp. of top of compressor is more than 120, compressor runs when the temp. of top of compressor is less than 105. 8.5.4When AC voltage 265V for 30 seconds, Outdoor Unit stops operation and alarms. When AC voltage 265V for 30 seconds, Outdoor Unit resumes operation. 8.3.5Inverter module Protection, Inverter module Protection itself has a protection function against current, voltage and temperature. 8.5.6Sensor protection at open circuit and breaking disconnection 8.5.7 Fan Speed is out of control. When Indoor Fan Speed is too high(higher than High Fan+300RPM)or too low(lower than 400RPM), the unit stops and LED displays failure -13-

information and can t return to normal operation automatically. 8.5.8Cross Zero signal error warning. If there is no Cross Zero signals in 4 minutes, the unit stops and LED displays failure information and can t return to normal operation automatically. 8.5.9Current protection: When the current is more than 16A, the compressor stops. 8.5.10Outdoor condenser high temperature protection: Under cooling mode, if T3>65 for 3 minutes, the compressor will stop. When T3<52, the protection is not valid. 8.5.11Outdoor low temperature protection: If the outdoor temperature is lower than -15 for 1 hour, the compressor and fan motor will stop. If the outdoor temperature is higher than -12 for 10 minutes and the compressor stops operation for 1h, or the outdoor temperature is higher than 5 for 10 minutes, then restart and enter into the prior operation mode. 8.5.12Compressor pre-heating function: When the outdoor temperature is lower than 3 and the compressor stops operation for more than 3 hours, or the outdoor temperature is lower than 3 and the power is just put on, the compressor enters into pre-heating condition. When outdoor temp. is more than 5 or user operate it, pre-heating condition will finish. 8. 6 Fan-only mode Fan speed is high/mid/low/ Auto 8.7 Cooling mode 8.7.1 Indoor fan keeps running, fan speed can be set in high/mid/low/ Auto: 8.7.2Auto fan at cooling mode: (T=Indoor Temp.-Setting Temp.) Room temp. up Room temp. down Condition T<1.5 1.5<T<4 T>4 Indoor fan speed Low Mid. High T> 3 High 1 <T<3 Mid. T<1 Low 8.7.3Anti-freezing control to indoor evaporator at cooling mode( T: evaporator temp. ) Evaporator Temp. Compressor T< 4 Off T > 8 On 8.8 Dehumidifying mode 8.8.1the indoor fan is fixed in low speed 8.8.2Low room temperature protection: When room temperature decreases to below 10, indoor fan stop, when room temperature restores to over 12, indoor fan start. 8.8.3At dehumidifying mode, the anti-freezing function of the indoor heat exchanger is the same as that of cooling mode. 8.9Heating mode 8.9.1Indoor Fan actions at heating mode Indoor Fan can be set at HIGH/MID/LOW/AUTO by using a remote controller, but -14-

Anti-cold wind function prevails. Anti-cold wind control function at heating mode Condition Indoor fan speed T= Indoor exchanger temp. Indoor exchanger temp. T<34 Off up 34<T<37 Breeze 37<T<44 Low speed T> 44 Setting fan speed Indoor exchanger temp. T> 38 Setting fan speed down 33<T<38 Low speed 24<T<33 Breeze T<24 Off 8.9.2Auto wind at heating mode Condition T=Indoor Temp.-Setting Temp. Room temp. up T<1.5 1.5<T<2.5 T>2.5 Room temp. down T<1.0 1.0<T<2.0 T>2.0 Indoor fan speed High Mid. Low High Mid. Low 8.9.3Indoor evaporator high-temperature protection at heating mode Condition Compressor T= Indoor exchanger temp. T<48 On 53<T<63 Decrease frequency of compressor T>63 Off Defrosting operation (Available for heating only). 8.10 Defrost 8.10.1Defrosting condition: The temperature of outdoor heat exchanger remains consecutively lower than -2 c for more than 40 minutes, 8.10.2Ending condition of defrosting If one of following conditions is satisfied, end the defrost and turn into heating mode: a. The defrost time has reached to 10 minutes. b. When the temperature of outdoor heat exchanger rises up to 15 C 8.10.3Defrosting Actions: a. Compressor runs. b. 4 way valve switches off, c. Outdoor fan switches off 20-15-

d. Indoor fan running according to anti-cold wind function in heating mode. 8.11Automatic operation mode The air conditioner automatically selects one of the following operation modes: cooling, heating or fan only according to the temp. difference between room temp. (TA) and set temp. (TS). TA TS Operation mode TA TS>2 Cooling -1 TA-TS +2 Fan-only TA-TS<-1 Heating (air-only for cooling only type) 8.12Manual switch 8.12.1Mode changes when push this button. Cooing mode Auto modeunit off Cooing mode 8.12.2At Cooing mode, after 30 minutes cooling operation whose fan speed is set as low, the A/C operates with a setting temp. of 24. 8.12.3At auto mode, the A/C operates with a set temp. of 24 8.13Timer Function 8.13.1The maximum length of timer is 24 hours and the minimum resolving power is 15 minutes. 8.13.2Timer on: first turn off the A/C, the A/C will be automatically on at the set time. 8.13.3Timer off: first turn on the A/C, the A/C will be automatically off at the set time 8.13.4Timer on/off function( on time is earlier than off time): first turn off the A/C, it will be automatically on at set time, and later be off at the set time, then unit turns on at set time. 8.13.5Timer off/on function( off time is earlier than on time): first turn on the A/C, it will be automatically off at set time, and later be on at the set time, then unit turns off at set time. 8.14Sleep mode 8.14.1It is available at cooling, heating or auto mode. 8.14.2 Cooling: The set temperature rise 1 per hour. Two hours later, the set temperature will maintain as a constant and the fan speed is kept at low speed. 8.14.3 Heating: The set temperature decrease 1 per hour. Two hours later, the set temperature will maintain as a constant and the air circulation is kept at low speed (Cold air proof function takes precedence over all). 8.14.4 Auto: The Sleep Mode running function operates in accordance with selected running mode by auto mode. 8.14.5 After 7 hours, unit cancels this mode automatically. J2 On On Off Off J3 On Off On Off Stop time 7 hours 8 hours 6 hours 7 hours 8.14.6 Auto restart function -16-

In case of a sudden power failure, this function automatically sets the unit to previous settings before the power failure when power returns. 8.15 Plasma Plasma turns on when the indoor fan runs. Plasma turns off automatically when front panel is opened. 8.16 Mode conflict The indoor units can not work cooling mode and heating at same time. Heating mode has a priority. 8.16.1Definition Cooling mode Heating Mode Fan Off Cooling mode No Yes No No Heating Mode Yes No Yes No Fan No Yes No No Off No No No No No: No mode conflict; Yes: Mode conflict 8.16.2 Unit action In case of one Indoor unit working in cooling mode or fan mode, and another indoor unit is set to heating mode, the indoor unit working in cooling mode or fan mode will change to stand by. The outdoor unit will work in heating mode. In case of one Indoor unit working in heating mode, and another indoor unit is set to cooling mode or fan mode, the indoor unit setting to cooling mode or fan mode will change to stand by. 9.Troubleshooting 9.1 Safety Because of there are capacitors in PCB and relative circuit in outdoor unit, even shut down the power supply, electricity power still are kept in capacitors, do not forget to discharge the electricity power in capacitor. The value of resistance is about 1500 ohms to 2000 ohms -17-