GFD. GVD V-shape coil condenser. Güntner Info. 8 additional basic models for container transport!w. V-shape coil drycooler

Similar documents
Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

Compact VERTICAL FLAT. Compact. Condensers GCHC/GCVC for HFCs, NH 3

GHF CXGHF GGHF. The all-in-one solution for commercial refrigeration! Güntner Info. High efficiency wall/ceiling-mounted air cooler. 0.

Güntner Info GHN. Vario Cubic for all refrigerants kw. Variable aircooler for industrial refrigerationw

Vario V-SHAPE. GVD condenser for HFC and propane, AGVD condenser for NH 3 GGD gas cooler for CO 2 GFD fluid cooler for water/glycol and other fluids

Güntner Info. finoox technology. fin and tube heat exchangers. Tailor-made solutions!

Vario VERTICAL FLAT. Vario. Condensers GCHV/GCVV for HFC, NH 3

Condensers / Dry coolers

Güntner Info GVH GVV. Condensers GFH GFV. Drycoolers. 8 kw 1,300 kw. Robust and flexible!

INFO. Compact V-SHAPE. Condenser GCDC for HFCs and propane Gas cooler GGDC for CO 2 Fluid cooler GFDC for water/glycol and other fluids.

INFO. Evaporative Condenser Stainless Steel MW. The Best Choice In Evaporative Cooling

INFO. Stainless Steel Evaporative Cooler. The New Choice In Evaporative Cooling

GMM Güntner Motor Management

IntrCooll. Cool large buildings at 80% lower running costs

Compact SLIM. Air cooler GASC. Air coolers in a flat design with forced draught fans Optimal for commercial cooling. HFCs, CO 2 0.

QUANTUM. Series and features of the energy-efficient chiller series

INFO. Compact DUAL. GADC Air Cooler for HFC and CO 2. Dual discharge air cooler with and without integrated condensation water pump.

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

Discover ebm-papst in commercial kitchen equipment. Durable and reliable products for constant use.

Compact CUBIC. Air cooler GSF. Highly efficient compact air cooler Optimal for commercial refrigeration. HFCs 1 55 kw

Evaporators 60HZ version

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp)

Innovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

Data Centre Cooling Solutions

PRODUCT GUIDE

Data Centre Cooling Solutions

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

LZT High efficiency air to water heat pumps with E.V.I. compressors

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

Contact-Cooled Rotary Screw Air Compressors. R-Series kw ( hp)

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Powerful and reliable. Also for high ambient temperatures. weco Compact chillers

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

ErP. ErP READY. The Eco-Design Directive ErP for refrigerator systems and heat pumps. READY

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Leadership, Innovation, Advanced Technology Synergise Here!

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design

Innovation for a Better & Greener Future

Main technical datas:

COMPRESSOR SYSTEMS MADE IN GERMANY G-DRIVE & V-DRIVE SCREW COMPRESSORS

Atlas Copco. Heat-of-compression rotary drum dryers ND series ( l/s, cfm)

Remote Air Cooled Condensers C2 Series

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

TOPAZ ADIABATIC COOLER

LTG High Pressure Humidifier and Airwasher

Water (R718) The Safe & Natural Refrigerant. echiller Future Proof Refrigeration

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

AIR COOLED CONDENSERS

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

Spiralair SPR 2-30 TECHNOLOGY YOU CAN TRUST

High Speed Turbo: the new benchmark for oil-free compressed air

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

Galletti Water chillers and heat pumps catalogue

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Product Family Overview

air handling units AT THE LEADING EDGE OF AIR FLOW

DRYVAC SERIES A new idea for smart pumping

Compact. Efficient. TROX.

Energy-efficient heat source provides comfort in large rooms

AMONUM chillers. Eco-friendly cooling in compact packaging, easy maintenance and safe. Optimal use of energies. engie-refrigeration.


Be sustainable while protecting your business

SIMPLICITY OR FULL MODULARITY?

Dry-Running Rotary Screw Compressors

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

FILLING TECHNOLOGY FROM THE EXPERTS SAFE, CLEAN, POWERFUL

New Bitzer factory: Higher precision with air conditioning

A cast iron case for our modular motors: High-voltage motors H-compact PLUS

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Refrigerant air dryers. FD series ( l/s, cfm)

Masters in energy efficiency

Performance Data ADSORPTION CHILLER AGGREGATES & SYSTEM COMPONENTS

INDUSTRIAL APPLICATIONS THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

HEAT RECOVERY WITH AERZEN TURBOS, BLOWERS AND COMPRESSORS. Reduce costs for compressed air generation

alpha.line FIRST CHOICE FOR SMALL AND MEDIUM FORMATS Member of the technotrans group

IMMERSIBLE PUMPS FOR INDUSTRY

VARIABLE SPEED DIRECT DRIVE CENTRIFUGAL AIR BLOWERS

THERMAL SOLUTIONS FINNED TUBES AND HEAT EXCHANGERS FOR GREATER EFFICIENCY

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

Oil-Less Rotary Screw Compressors

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

Energy consumption storage facilities examined in ICE-E

Efficient Motor Technology for the Home Appliance Industry

Advance Split

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

OGA / OGV Nordbaden eg Bruchsal relies on Güntner cooling components

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

RENNER SCREW COMPRESSORS WATER-INJECTED 100% OIL-FREE COMPRESSED AIR Made in Germany

Transcription:

Güntner Info GFD V-shape coil drycooler GVD V-shape coil condenser also available with HydroSpray system 75 kw 2 MW 8 additional basic models for container transport!w

Customized solutions for every application Optimal High efficiency transportation fans Maximum capacity range - Capacity range from 75 kw to 2 MW - More than 5,700 unit variants available - 8-basic Fans models with optimal for truck ventilation shipment and sound characteristics - 8-basic Available models in AC for or container EC technology shipment - Optional - Maintenance-free guide rails for fans container with long loading service life - Excellent energy efficiency class Various Transportation combinations by crane possible without cross beams - Various material combinations - Different materials by andcrane tube with geometries selectable - Simple tube transportation Different pipe circuiting possible two movable crane lugs Different fin spacings available - Quick and easy positioning - Optimal load distribution - High torsional stiffness Suitable for all fan control types - Step control (GMM step) Phase cut controller (GMM phase cut) Frequency converter (GMM sincon ) EC fans with Güntner Motor Management (GMM EC) - Wired at factory Minimum footprint - High power density due to maximum unit height - Reduced costs for transport - Reduced amount of fans Cleaning orifice - Cleaning drain as standard Minimum amount of feet - Easy to open, no tools needed - Water cleaning can drain unimpededly - Highfrom static stability - Reduced expense for substructure, to be provided on-site by customer - Optional: with vibration dampers High air operational Optimal supply reliability enhanced leakage - Fanand separation sheets as standard protection - Performance control floating via stopping of individual fans possible - Proven Güntner coil principle - High operational due to distribution: one fan - Coil rests on reliability floating bearing per-chamber No contact to separation or front plates - No strain on fluid-carrying tubes

Optimal transportation - 8 basic models for truck shipment - 8 basic models for container shipment - Optional guide rails for container loading Various combinations possible - Various material combinations - Different tube materials and tube geometries selectable - Different pipe circuiting possible - Different fin spacings available Competence for unique system solutions The GFD/GVD series consists of modules, so that the units can be used for low as well as for high capacities. The units are available as drycoolers or condensers. Due to the different models, the units can be precisely adapted to specific requirements. The result is a ready-to-operate solution that will more than satisfy your expectations concerning material combination, performance, sound requirements or controllers pre-wired at factory. Güntner HydroSpray -System The Güntner HydroSpray system is available in Basic and Professional versions. Cleaning orifice - Cleaning drain as standard - Easy to open, no tools needed - Water from cleaning can drain unimpededly High operational reliability and enhanced leakage protection - Proven Güntner floating coil principle - Coil rests on floating bearing - No contact to separation or front plates - No strain on fluid-carrying tubes

Special features of the GFD / GVD 40 % higher performance - Up to 2 MW per unit - Increased power density due to larger heat exchangers - Certified by Eurovent Certified performance reliability Knowledge, experience & know-how provided by a competent supplier 20 % higher fan efficiency - Larger bare coil per fan - Motor Management for EC fans - High fan efficiency due to optimal air supply 30 % less footprint - Less space required - Minimum amount of feet - Less effort on-site for substructure As member of the Eurovent certification program, we guarantee the performance of our products. For the certification, all series of the participating companies are tested and approved by specifically authorized laboratories. With units certified by Eurovent you can rely upon the fact that the indicated performance will effectively be achieved. For certain. The GFD/GVD is a V-shape heat exchanger that is available as drycooler or as condenser. The GFD/GVD consists of 8 + 8 basic models for a large variety of units, thus an optimized solution can be provided for every application situation and every kind of shipment. For satisfying the high demands of our customers. GFD GVD Variants Application range Power spectrum in kw 2x2 2x9 fans Heat dissipation into the air; outdoor installation 75 1700 2x2 2x9 fans Refrigerant condensation with air; outdoor installation 125 2000 Refrigerant Water glycol mixture For all refrigerants, except NH 3 * Air flow direction Quality standard Dimensions (in mm) Weight in kg Horizontal air aspiration (from two sides); vertical air discharge ISO 9001 from L 3284, B 2300, H 2850 to L 12139, B 2300, H 2850 1774 6098 Horizontal air aspiration (from two sides); vertical air discharge ISO 9001 from L 3284, B 2300, H 2850 to L 12139, B 2300, H 2850 1672 5690 *as special equipment with stainless steel tubes also for NH 3

Special features of the GFD/GVD container version Additional 8 basic models for container transport High power density Large range of unit variants Dimensions optimised for container transport When it comes to international projects, it is important that the transport be as cost-efficient and uncomplicated as possible. For this reason, the units of the GFD/GVD series are now also available as serial products with dimensions optimised for the transportation in containers. These variants offer the same broad range of unit types as the GFD/GVD versions for transportation by truck. The V-coil units offer a high power density with a minimum footprint. Although the number of legs is minimal, the units have high static stability. Due to the impressive torsional stiffness, the units can be transported by crane without using a cross-beam. Two factory-mounted crane lugs ensure that lifting and positioning the unit by crane is easy and safe. All units of the container version have the exact width and height to fit perfectly into a container. In their basic version, they are designed for fork lift transport; optionally, however, they can be fitted with a factory-mounted guide rail for perfectly easy loading and unloading into and out of the container. GFD/GVD for container transport Crane transport without cross beam with only two crane lugs Broad power range Variants 2 x 2 2 x 9 fans Application range Heat dissipation into the air; outdoor installation Power spectrum in kw 70 1930 Refrigerant/Fluid Water / glycol mixture; all refrigerants except NH 3 * Air flow direction Horizontal air aspiration (from two sides); vertical air discharge Optional guide rail, factory mounted Quality standard Dimensions (in mm) Weight in kg ISO 9001 From L 2634, B 2300, H 2532 To L 11489, B 2300, H 2532 1116 6315 * as special equipment with stainless steel tubes also for NH 3

Fans and fan control ErP-ready even today! Use of AC and EC fans The GFD / GVD is equipped with high efficiency, direct drive axial fans. Motor, impeller, nozzle and protection guard form an entity with optimal ventilation and sound insulation characteristics. These fans are available as axial fans in two technologies: with AC motors or optionally with EC motors. All fans are wired at factory. The parameters of the EC fans are set at factory, so that they are ready for operation. The ErP Directive forms part of the Ecodesign Directive. It is relevant for fans insofar that the Directive stipulates minimum efficiency requirements that have to be met as of January 1st, 2013. These requirements will become even more strict in 2015. Güntner has already replaced the majority of fans so that even today, we are ErP-ready. AC (alternating current) EC (electronically commutated) EC motors technology of the future! Compared to conventional systems, it is possible to save energy by using EC fans with the GMM. EC motors are equipped with optimized power electronics, especially developed and designed for these motors. Compared to AC motors, the motors of EC fans have no winding in the rotor, but a permanent magnet instead. Due to this fact, there are no induction losses or slip losses in the rotor. Especially for speed controlled applications, the EC technology offers a larger variety of benefits. Diameter Protection class Type Continuous control 800 mm, 900 mm IP 54, wired at factory Three phase current 50 or 60 Hz - Phase cut controller GMM phase cut - Frequency converter with all-pole sine filter GMM sincon 800 mm, 900 mm IP 54, wired at factory Alternating current and three phase current, pre-set parameters, ready for operation, 50 and 60 Hz Güntner Motor Management GMM Step control Standard: Step controller GMM step EC fans + GMM = optimized energy efficiency Controllers of other manufacturers can also be used. For frequency control, an all-pole sine filter has to be installed. Switch cabinets and control concepts: Each GVD / GFD can be supplied with the corresponding switch cabinet, the switch cabinet can be delivered with or without Güntner controller. You can choose between standard switch cabinets and customized switch cabinets. All switch cabinets are designed, built and tested at Güntner. Together with you, we design and provide a switch cabinet and control concept that is precisely adapted to your specific application. These switch cabinet concepts are optimally adjusted to the requirements. Depending on their size, they can be mounted directly to the heat exchanger. If direct mounting is not possible, the switch cabinets are delivered separately with the unit. On request, Güntner provides connection and startup of the switch cabinets on-site by our service personnel. Güntner Controls developed the Güntner Motor Management system GMM especially for EC fans. Only the combination EC fan with GMM creates an intelligent control system for an energetically optimal operation. The Communication effort for installation of switch cabinets to main system and wiring is reduced considerably. With the optional bus interface, main systems can be integrated (e.g. energy management, remote maintenance, etc.). You would like to know more about the Güntner Motor Management? Ask for our GMM knowledge brochure! Contact: sales@guentner.de P GMM T Pressure sensor Temperature sensor BUS system Management Control BUS system

Improved performance through spraying Spraying coils with water can significantly improve the performance of finned heat exchangers. Especially in refrigerating plants implementing free-cooling (e.g. for the cooling of server racks) it is possibly to realise considerable energy savings by using a water spray system. It is possible to improve the COP by up to 40 % through using a spraying system in a refrigerating plant when there are high ambient temperatures and the spraying is used to lower the condensing temperature. Your benefits in using a spray system Improving the operational safety of the refrigerating plant Unexpected temperature peaks during summertime are counteracted by the spray system and thus cannot lead to a plant failure. Lowering of the fluid temperature With spraying, the temperature of the cooling fluid can be lowered significantly. Thus, it is possible to prolong the use the operating times for free-cooling. Alternatively, sprayed systems can also be used for processes requiring temperature levels that otherwise can only be reached with compression refrigerating plants. Lowering of investment costs Due to the increased performance effected by the spraying system, it is possible to use smaller drycoolers / condensers while maintaining the same fluid temperature. Alternatively, it is possible to use smaller refrigerating machines while maintaining the original size of the drycoolers / condensers. Saving operating costs If smaller drycoolers / condensers are used, energy costs for the fans actuation may be saved. It is more reasonable, however, to maintain the unit size for the drycoolers / condensers and lower the fluid or condensing temperature through spraying, thus increasing the plant s COP.

Güntner HydroSpray The intelligent system Special features of the HydroSpray system Two versions of the Güntner HydroSpray system are available; Basic and Professional. The appropriate version has to be selected depending on the application case and the installation site. Basic Number of spraying hours Up to 300 h/a Up to 1,000 h/a Section Cycling No Yes Softening Yes Yes Professional Automatic water suction pump Water consumption only 50 % of common systems Scale-resistant flat spray nozzles Up to 1,000 h/a of spraying Demineralization No Yes Pressure boosting Optional Yes UV sterilization Optional Optional Available up to unit size 2 x 9 fans 2 x 9 fans Güntner HydroSpray -System Basic The simple system for a multitude of applications With the Basic system, the spraying is switched on when a defined switching point is exceeded. All fan chambers are sprayed simultaneously. The system is recommended for applications in which the spraying time does not exceed 300 h/a. The Basic spray system is the most appropriate solution to: - cover peak loads occurring during summer - use a smaller unit and thus save investment costs - minimize the footprint Güntner HydroSpray -System Professional The intelligent system with Section Cycling The Section Cycling is an adaptative sectional spraying of the unit. Each fan chamber forms a section; the nozzle for each section is controlled individually by the system. For this reason, there is no abrupt and massive increase of performance when the system is switched on, but the performance is increased in steps as the individual sections are switched on. With this approach, a sharp decline in the condensing pressure is avoided; the maximum saving in the amount of costly treated water is achieved. The Professional spray system is the most appropriate solution to: - lower the medium temperature for extended periods of time - use in sprayed systems in the areas of air conditioning or process cooling where low switching temperatures are used - achieve optimized control and minimize the use of treated water Low operating costs: No chemical additives, no high-pressure pump Hydro Management controller pre-installed and wired at factory: you just connect power and water outlets Calculation based on climate data Due to retractable system, transport dimensions stay unaffected Amount of water adjustable in up to 9 steps

Güntner Hydro Management GHM spray Comparison of systems having the same heat exchanger surface area For our HydroSpray spraying system, we developed a controller that offers unique features and advantages. The controller GHM spray controls the water spraying depending on the performance required of the heat exchanger and the gauged temperatures and pressure. The heat exchanger s performance is thus enhanced. Necessary information, e.g. fan speed, are read out via bus communication or transferred by a digital signal. There are two different systems: Basic System The GHM spray basic offers one step spraying. This system controls the spraying of the heat exchanger depending on different parameters (e.g. pressure or temperature). The system is used to in crease the heat exchanger s performance at peak load times. Professional System The GHM spray professional can cover up to nine sections. This means that the heat exchanger is sprayed according to sections, thus considerably reducing water consumption. Moreover, the service life of the heat exchanger is prolonged by the socalled Section Cycling feature. Dry type cooler HydroSpray Basic without Section Cycling HydroSpray Professional with Section Cycling Performance Heat exchanger surface Number of spraying hours Investment Water consumption Operating costs Water treatment Due to their construction and material combination, aircooled finned heat exchangers are optimized for operation with dry air. During spraying and the evaporation of water, lime scales start to form, leading to incrustations. The minerals dissolved in the water (salts, among other things) may lead to several corrosion effects. The percentages of calcium carbonate and minerals dissolved in the water can be very diverse and depend on the location. For this reason, the untreated water s composition has to be analyzed individually for each location in a project. In order to ensure the undisturbed operation of sprayed drycoolers / condenser in the longterm, we defined the appropriate requirements for the quality of water. For cases in which the duration of the spraying is quite short, in most cases it is sufficient to use a simple water softening plant. If, however, the objective consists in minimizing energy costs and maximizing the duration of the spraying to up to 1,000 hours, it is necessary to also implement a demineralization plant based on the reverse osmosis principle in addition to the softening plant. low very high

Our competence for your benefit! Application-specific consulting Our specialists are at your disposal as contact persons and are ready to give detailed advice anytime. They design the unit according to your requirements for optimal adaptation to your application or develop a complete concept for a ready-to-operate solution. Fans We use high efficiency, direct drive fans for continuous control that are two-plane balanced according to DIN ISO 1940 part 1, i.e. they comply with the balance quality Q 6,3. The fans are maintenance-free and have an extended service life. With Güntner units, you are ErP-ready today! Leakage protection Due to Güntner s tried and tested floating coil principle, the heat exchanger coil can expand without affecting the fluid-carrying tubes; in consequence the tubes are not in direct contact with casing parts (front plates/separation plates). The heat exchanger coil rests on floating bearing and thus is protected from leakages. GPC Güntner Product Calculator For a precise thermodynamic design we recommend to use our calculation software Güntner Product Calculator. The software also allows for precise, simple design of the switch cabinet with control components, corresponding to your application. Güntner Controls Güntner Controls is an individual department at Güntner supplying performant and high quality controllers and switch cabinets. Our experts develop project-specific solutions to satisfy highest requirements in all sectors. We provide a switch cabinet solution for your individual application suitable for EC and AC fans. With us, everything stays under control! Sound requirements Extensive test series in the companyowned laboratory ensure that, already during unit design with the Güntner Product Calculator, fans optimized to the sound requirements of your installation are selected. You do not have the Güntner Product Calculator? Download the GPC from the Güntner Website or request a CD! www.guentner.eu Service After Sales Our Service After Sales supports you in case of problems and answers your questions. If necessary, our colleagues can be promptly on-site to take care of your concerns. Our employees of Service After Sales are not only experts in refrigeration engineering, they are also qualified in further specific fields, i.e. as certified welders for different tube wall thicknesses and materials. Errors excepted. Subject to technical amendments without prior notice. KAT 224.2 / V3 / 13.02.2013 For further information, please contact our sales department: sales@guentner.de Güntner AG & Co. KG Hans-Güntner-Str. 2-6 82256 Fürstenfeldbruck Germany www.guentner.eu