ATOMIC ABSORPTION SPECTROMETER AAS 3500 EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

Similar documents
Affordable Lab Technology

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

Atomic Absorption Spectrometer

PG 990 Atomic Absorption

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

CENTRAL STERILE SUPPLY DEPARTMENT

Blowers - HIGH PRESSURE BLOWER - HIGH VACUUM BLOWER

Analytical Technologies Autoclave (3420BT)

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

AAnalyst 700 Atomic Absorption Spectrometer

Analytical Technologies XRF 3005

SP-3800AA Atomic Absorption Spectrophotometer

INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

AAnalyst 600/800 atomic absorption spectrometers

ice 3000 Series Atomic Absorption Spectrometers

detectors UltiMate 3000 Variable Wavelength Detectors

The New Digital BWB Flame Photometer Range

t. +44 (0) f. +44 (0) e. w.

The New Digital BWB Flame Photometer Range

Technical specifications of FT-IR Spectrometer

Model S FT-IR SPECTROMETER

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

Forked Pyrolytic Platforms

Variable Temperature Options for Optical Experiments

CS744 Series: Carbon/Sulfur by Combustion

Mercury Vapor Monitor VM-3000

Specifications Wavelength Range: 190 nm to 800 nm continuous

An FT-NIR Primer. NR800-A-006

Who is GBC Scientific Equipment?

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

HPLC Column Ovens and Temperature Controllers

VM-3000 Mercury Vapor Monitor

Nexera-i Specifications Prominence-i Specifications

HYDROCARBONENGINEERING June June 2015

Measuring Stokes shift. Easy, fast and reliable

VM-3000 Mercury Vapor Monitor

M&S Series Atomic Absorption Systems

C122-E058C. AA-7000 Series. Shimadzu Atomic Absorption Spectrophotometers

Nicolet Evolution 300. UV-Visible Spectrophotometer

Labtronics.

Precision Temperature Control. Pulse Free Pump. Column Oven. Superb Performance Ion Chromatography. Leak Detector. Modular Flexibility

BENEFITS. QUATERNARY HPLC SYSTEMS Quaternary and Other Gradients. The Complete Range of HPLC. Convenience of Maintenance. Systems Configuration

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

Atomic Absorption Spectrophotometers. AA Series C122-E058E

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Common Features of DX-600 Modules

Corporate Overview. April

Series 9000 Total Hydrocarbon Analyzer

Chemistry Instrumental Analysis Lecture 4. Chem 4631

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications


16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

PSA Series. Particle Size Analyzer

A Platform for the Future ULTIMA 2 ICP OPTICAL E MISSION S PECTROMETER

NanoReady. Micro UV-Vis Spectrophotometer

Customised HPLC Systems for Highest Performance

Customers should provide all necessary operating supplies upon request of the engineer.

Lighting Measurement Solutions

FPD - Flame Photometric Detector

CombustionONE. Improving and Sustaining the Combustion Asset. Driven by the New Standards. Bulletin 53A90A01-01E-A

Thermo Scientific Dionex UltiMate 3000 Fluorescence Detectors

HISTORY OF VARIAN CAPILLARY INJECTORS

HFID Heated Total Hydrocarbon Analyzer Module

Agilent 1290 Infinity II Vialsampler Data Sheet

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Multiple Gas Analyser 3000 Series

IC Professional Detector

Tekmar-DOHRMANN The 3100 Sample Concentrator From ManualLib.com

UV CURING SYSTEMS OmniCure UV Curing Lamp & LED Systems TO ORDER, PLEASE CALL

Soil and Plant Methods List for Automated Ion Analyzers. Flow Injection Analysis

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

NOTICE INVITING TENDERS FOR THE PURCHASE OF 1. FLASH CHROMATOGRAPHY 2. ION CHROMATOGRAPH 3. MICROWAVE MUFFLE FURNACE

Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples

Variable Temperature Microprobe Systems

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

Laser Particle Size Analyzer

Introduction to the Fusion TOC Analyzer

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

Datalogging as standard

FPI Detectors Pyroelectric Detectors with Spectrometer Functionality

MicroRay IR-100 NEW. Inspection MicroRay IR-100

CALIBRATION HOW IT WORKS

o Clear instruction for operation o Measurement and control of o Stationary sensor for o Programming capabilities of o Countdown timer selectable

FIXED GAS ANALYZER (FGA)

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

intrinsically safe detector for hydrocarbon gases

LSM Quadrant Source and Measure Unit for LED Production Tests. Two Global Leaders. One Complete Solution.

Key Features. General Description

Tubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

ELD500 PRECISION LEAK DETECTOR

CALIBRATION HOW IT WORKS

Equipment specifications (D6)

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

WHAT IS LASER ULTRASONIC TESTING?

SEC Signature Process Gas Analyzer

Transcription:

Turnkey Laboratories Solutions ATOMIC ABSORPTION SPECTROMETER AAS 3500 EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES Analytical Technologies Limited An ISO 9001 Certified Company www.analyticalgroup.net

The AAS 3500 Atomic Absorption Spectrometer is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications including: Agricultural Food Geological Clinical Metal Petrochemical Environmental Mining Pharmaceutical The versatile instrument is available in three configurations: AAS 3500 The instrument is equipped with a flame atomiser only. The positioning of which is fully controlled by the embedded computer system and AA win software. Three flame options are available to the user with Air/Acetylene being the standard configuration. This flame can be used for nearly all standard elements while the N2O/Acetylene and the Air/LPG (Natural gas) are available as an option for the more demanding of elements. All threee flame configurations offer coded burner for full safety protection. The instrument is equipped with a graphite Furnace Atomiser only. The graphite head is fixed into the optical path to maximise performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tube are supplied as standard to improve the performance. The instrument is equipped with both Flame Atomiser and Graphite Atomiser as described above. Both configurations are installed into the instrument and can be changed over by a simple selection in the versatile AA Win software

FEATURES & FUNCTIONS Embedded PC system built into the instruments as standard on all configurations, Pre-installed AAWin3 software, user manuals, cook book and windows operating system. AAWin3 software provides full control of the instrument and autosampler with easy method change for each technique. Now GLP compliant. Automatic 8 Hollow Cathode lamp turret controlled and optimised by the AAWin3 software. Operating lamp current and warm-up lamp current can be individually controlled to eliminate drift commonly associated with lamp warming. D2 lamp background correction system fitted as standard to all configurations. High energy D2 lamp and adjustable beam splitter mirror are optimised by the AAWin3 software. Self Reversal background correction system fitted as standard to all configurations. The high performance background system uses the same hollow cathode lamp as installed for the analysis. Minimum extra components are required and used for any element at any wavelength making it extremely versatile. High precision minimal optics ensures maximum light throughput to the computer controlled Czerny-Turner mono-chromator. A universal autosampler is available as an optional accessory which is conveniently mounted on the front of the instrument. Optional XYZ autosampler provides high sample volume for multi element analysis along with scalable sample capacity for high sample throughput Absorption and Emission modes are standard features in the AAWin2 software as well as peak height, peak area, sequential and manual integration modes.

FLAME ATOMISER FEATURES The flame atomiser offers three flame options: Air/acetylene is the standard configuration with the N2O/acetylene and Air/LPG as options. Air/acetylesne The Air/Acetylene flame uses a 100mm single slot burner for the standard configuration. The high sensitivity (Cu 2ppm >0.280abs) is due to the effeciency of the fixed position glass nebuliser fitted as standard. An acid resistant replacement is available as an option. The flame can be easily set from blue lean flame through stoichiometric to fuel rich by means of computer control. N20/Acetylene The N2O/Acetylene flame uses a 50mm single slot burner and is available as an optional extra. This Flame configuration is used to measure elements less prone to ionization such as: Aluminium, Tin, Titanium, Calcium, Vanadium and Molybdenum. Switching from Air/Acetylene to NZO/Acetylene to Flame Off is fully controlled by the AAWinPro software.

AIR/PROPONO (LPG) This flame uses a 3 slot burner and with the low pressure requirement it is also much safer to operate. Due to the low temperature of the flame it is ideal for analysing alkali metals such as: Potassium, Sodium and Lithium, especially when used in the emission mode. Some remote areas of the word have difficulty obtainig Acetylene gas of a high enough purity to operate the flame correctly, LPG can give a real alternative and offer comoaeable results for most elements througthout the wavelength range. SAFETY FEATURE: Pressure monitoring for all gases Burner identification Flame sensor Drain Trap level Sensor Gas Leak Detector Over Pressure in Premix Safety Cut off Switch Graphite Atomiser Features The integrated Graphite Furnace Atomiser is available in two instrument configurations. In the AAS3500 instruments the graphite furnace head is fixed into the ligh path so alignment with the optical path is simple and accurate. In the AAS3500 instrument the graphite furnace head is fixed behind the flame atomiser assembly and is motorised into position by a simple operation in the AAWinPro software. The positions for the flame and graphite are saved making it easy to swap between modes for different analysis. The temperature of the transversely heated graphite tube is accuratelly controlled by means of to reduce feedback system and has been designed to reduce analytical problems normally associated with this type of technique. (Max Temperature is 3000 degrees C)

Pyrolytically coated graphite tubes are used as standard and are manufactured preformance as well as increase the analytical life. to improve Platform graphite tubes are supplied as stamdard and will accept volumes up to 20μl. Non platform graphite tubes are also availabl as an optional extra. Up to 10 heat stages are available for the programming of the graphite atomiser. These can be set and stored within the AAWinPro software. The grahite tube is held in position by means of a gas piston. Replacement of the graphite tube is perrformed by a simple command in the AAwin Software. The graphite tube is efficiently cooled by an additional water circulation system (supplied separately). SAFETY FEATURE: Argon Gas pressure Sensor Water flow sensor Over Temperature Sensor Broken graphite tube protection Both configurations are installed into the instrument and can be changed over by a simple selection in the versatile AA-Win software.

Specifications Wavelength range Monochromator Spectral Bandwidth Wavelength Accuracy Wavelength Reproducibility Resolution Baseline Stability Sensitivity (Cu) Detection Limit Repeatability Background Correction Characteristic Concentration Burner Heads Nebuliser - Micron Mist Atomization Chamber Position Adjustment Safety Functions 185nm-910nm Czerny-Turner Configuration (Double Beam Option Available) 0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm, (software selectable). + 0.15nm < 0.05nm 0.2nm + 0.02nm 0.005A/30min 2µg/ml Absorption > 0.28A (flame) Cu <0.004 µg/ml (flame) Cd < 0.4 x 10-12g (graphite furnace) Cu <0.7% (Air/Acetylene flame) Ba <1.0% (Nitrous oxide/acertylene flame) Cu < 2.0% Cd < 2.0% (Graphite Furnace) Deuterium Arc, Self reversal Cu < 0.02 µl/ml, Ba < 0.15 mg/ml (N2O/Acetylene) Titanium alloy (Burner Position- Height and Rotation controlled via software) Inert Adjustable Nebuliser, Flow Rate from 2ml/min, Pt/lr capillary available for high acid concentration Corrosion-resistant material Automatic changeover (AAS3500GF) Manual (AAS3500GF) Automatic Setting of Optimum Height for Flame Burner. Burner Identification, Flame sensor, Gas leak Sensor, Low Gas Pressure Sensor, Drain Trap Sensor, Power Loss Protection, Circulation Water (graphite), Over temperature Sensor (graphite) We reserve the right to modify, revise/upgrade, suspend or discontinue any Product in whote or in partm either temporarily or permanently, with or without notice.

VER.17/11-1 Regulatory compliances Corporate Social Responsibility Analytical Foundation is a Nonprofit Organization (NGO) found for the purpose of: 1.Research & Innovation Scientist s awards / QC Professional Award : Quality life is possible by innovation only and the innovation is possible by research only, hence ANALYTICAL FOUNDATION is committed to identify such personallities for their contributions across various field of Science and Technology and awarding them yearly. To participate for award, send us your details of research / testing / publication at info@analyticalfoundation.org 2. Improving quality of life by offering YOGA Training courses, Work shops / Seminars etc. 3. ANALYTICAL FOUNDATION aims to DETOXIFY human minds, souls and body by means of Yoga, Meditation, Ayurveda, Health Care, Awards, Media, Events, Camps etc. Reach us @ Corporate & Regd. Office: Analytical House, # E67 & E68, Ravi Park, Vasna Road, Baroda, Gujarat 390 015. INDIA HPLC Solutions MultipleLabs Analytical Bio-Med Analytical Distributors Analytical Foundation (Trust) T: +91 265 2253620 +91 265 2252839 +91 265 2252370 F: +91 265 2254395 E: info@hplctechnologies.com info@multiplelabs.com info@analyticalgroup.net info@analyticalbiomed.com W. www.ais-india.com www.analycalgroup.net www.hplctechnologies.com www.multiplelabs.com Sales & Support Offices: across the country : Distributors & Channel partners World Wide Note : Company reserves rights to add/delete/modify the contents / technical specificationsof the catalogue without prior notice.