In data sheets and application notes which still contain NXP or Philips Semiconductors references, use the references to Nexperia, as shown below.

Similar documents
AN10943 Decoding DTMF tones using M3 DSP library FFT function

AN FXPS7xxx series pressure sensor self-test features. Document information

UM Store and transport requirements. Document information

MaxLite LED MICRO-T PANEL

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Duct Mount. Installation Instructions

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

CD6102 / CD6102 OC / CD6102-2

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

INSTRUCTION MANUAL HS-229G

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

APPLICATION NOTES for LED DISPLAYs

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

INSTRUCTIONS PARTS LIST For President, Monark, Standard, and Fast-Flo Pumps, and Agitator

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

Installation and Maintenance "L" and "LS" Series

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

Installation Manual Universal Side-of-Pole Mount UNI-SP/01A

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

ADT Security Website Terms of Use

MaxLite LED Vapor Tight Linear Fixture

SolarPRO CURVE HEATER OWNER S MANUAL

Installation Manual Universal Side-of-Pole Mount UNI-SP/02A

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

COOPER POWER SERIES. Types R, W, WV and RV reclosers, KA869R and KA835W series trip coils replacement instructions. Reclosers MN280020EN

2-Port alarmcharge Hub - Manual

Thanks for shopping with Improvements! Solar Pool Heater XF Item #

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions

Easy installation in both new construction and retrofit

Owner s Manual. PIR-1 IR Learner

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

View the expanded manual: GEN5

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

Air Pump Up to 800 gallons

COOPER POWER SERIES. QD3 Quik-Drive Tap-Changer Position Indicator Drive Gear Kit Number B11. Voltage Regulators MN225056EN

COOPER POWER SERIES. S.T.A.R. TM Fiber optic cable installation instructions. Fault Indicators MN320004EN. Fiber optic fitting (To led display)

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

SolarPRO XD3 HEATER OWNER S MANUAL

C L E A N I N G / M A I N T E N A N C E WA R R A N T Y I N F O R M AT I O N CLEANING/MAINTENANCE FAN STORAGE 3 YEAR LIMITED WARRANTY INSTRUCTIONS

Design Criteria. Installation

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Low Temperature Stainless Steel Panel Series Installation and Commissioning Guide

- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

Flat Line Spray Systems Kits

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

Installation/Operation Instructions COMP-COOL50/COMP-COOL50P 50 CFM COMPONENT COOLERS

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

Dolphin 9900 Mobile Computer

Pressurized Filter Up to 1250 gallons

3820, 3820i, 4820, 4820i

The Series LFII (TY3596) Residential

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

installation instructions Fan Tray System FTA-3/FTA-6

Corrosion Resistant Fluid and Air Handling Systems.

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

MaxLite LED Round Pendant Highbay Series

Gas Connector Installation Instructions

User s Guide Wireless Doorbell for IWATCHALARM (Add-On) Model: SM-105DB

SolarPRO CONTOUR HEATER OWNER S MANUAL

EQUIPMENT Operation Manual

Easy installation in both new construction and retrofit

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

KETTLE. Customer Assistance (US) Model Number: UPC:

Thermometer model 02059

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

FiRe mobile-2 Operation Manual

WDB2 Series Bearing Temperature Sensor

Effective May 2017 Supersedes October 1998 (S )

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

BTA. (Bulb Thermal Actuator) Data Sheet

VS2000V Veterinary Vital Signs Monitor Operation Manual

ALL-WEATHER LANDSCAPE BURIAL SUBWOOFERS Burial Subwoofers: 10 & 12 (250mm & 300mm)

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

Operation & Installation Guide

Apex MediTech ALC109 ALARM SYSTEM

INSTRUCTION MANUAL P Heating and 1 Cooling

5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

Installation Manual February Opticom Infrared System. Model 575 Confirmation Light Kit

Viessmann B1HA Boiler Series

RR-PM1200 OPERATING AND PROGRAMMING GUIDE

VX SERIES Wireless Thermostat with Occupancy Sensor

FloorHeat Installation Manual

Dimensions of the Optional Mounting Box (BB-400R/W)

Compact Equipment Warranty Policy

LETTER FROM THE FOUNDERS

Thermometer with Wired Sensor

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

ERGO BACKPACK VACUUM OWNER S MANUAL

Embedded Linux with VAR-SOM-MX6 Course

COOPER POWER SERIES. CT Protector Retrofit Kit. Voltage Regulators MN225057EN. Effective March 2017 Supersedes March 2010 (S )

TrueClean ToteCleaner

Transcription:

Important notice Dear Customer, On 7 February 2017 the former NXP Standard Product business became a new company with the tradename Nexperia. Nexperia is an industry leading supplier of Discrete, Logic and PowerMOS semiconductors with its focus on the automotive, industrial, computing, consumer and wearable application markets In data sheets and application notes which still contain NXP or Philips Semiconductors references, use the references to Nexperia, as shown below. Instead of http://www.nxp.com, http://www.philips.com/ or http://www.semiconductors.philips.com/, use http://www.nexperia.com Instead of sales.addresses@www.nxp.com or sales.addresses@www.semiconductors.philips.com, use salesaddresses@nexperia.com (email) Replace the copyright notice at the bottom of each page or elsewhere in the document, depending on the version, as shown below: - NXP N.V. (year). All rights reserved or Koninklijke Philips Electronics N.V. (year). All rights reserved Should be replaced with: - Nexperia B.V. (year). All rights reserved. If you have any questions related to the data sheet, please contact our nearest sales office via e-mail or telephone (details via salesaddresses@nexperia.com). Thank you for your cooperation and understanding, Kind regards, Team Nexperia

Mounting instructions for SOT78 (TO-220AB); SOT186A (TO-220F) Rev. 1 29 May 2012 Application note Document information Info Keywords Abstract Content SOT78; SOT186A; TO-220AB; TO-220F This application note provides mounting instructions for SOT78 (TO-220AB) and SOT186A (TO-220F) packages

Revision history Rev Date Description v.1 20120529 initial version Contact information For more information, please visit: http://www.nxp.com For sales office addresses, please send an email to: salesaddresses@nxp.com All information provided in this document is subject to legal disclaimers. NXP B.V. 2012. All rights reserved. Application note Rev. 1 29 May 2012 2 of 11

1. Introduction This application note provides mounting instructions for SOT78 (TO-220AB) and SOT186A (TO-220F) packages. 2. General data and instructions 2.1 General rules 1. Fasten the device to the heatsink before soldering the leads 2. Avoid stress to the leads 3. Keep mounting tool (for example, screwdriver) clear of the plastic body 4. When screw mounting, the washer must not exert any force on the plastic part of the body. 2.2 Mounting methods 2.2.1 Clip mounting Mounting with a spring clip gives: A good thermal contact under the crystal area, and slightly lower thermal resistance than screw mounting Safe insulation for mains operation. Minimum force for good heat transfer is 10 N. Maximum force to avoid damaging the device is 80 N. 2.2.2 M3 screw mounting It is recommended that a metal washer is inserted between screw head and mounting tab. Do not use self-tapping screws. Mounting torque for screw mounting (for thread-forming screws the values are final values): Minimum torque for good heat transfer is 0.55 Nm Maximum torque to avoid damaging the device is 0.80 Nm. When a nut or screw is driven directly against the tab, the torques are as follows: Minimum torque for good heat transfer is 0.40 Nm Maximum torque to avoid damaging the device is 0.60 Nm. 2.2.3 Rivet mounting non-insulated Do not pop-rivet the device to the heatsink. It is permissible to press-rivet the metal tab providing that eyelet rivets of soft material are used, and the press forces are slowly and carefully controlled. This method is not permitted for full-pack packages (SOT186A) because it damages the plastic encapsulation insulation properties. All information provided in this document is subject to legal disclaimers. NXP B.V. 2012. All rights reserved. Application note Rev. 1 29 May 2012 3 of 11

2.3 Heatsink requirements Flatness in the mounting area: 0.02 mm maximum per 10 mm. Deburr the mounting holes. For further information, see Section 3 Instructions for clip mounting and Section 4 Instructions for screw mounting 2.4 Heatsink compound The thermal resistance from mounting base to heatsink R th(mb-h) can be reduced by applying a smear of aluminium oxide compound between the contact surfaces. Values given are of thermal resistance using this type of compound. Dow Corning 340 Heat sink compound is recommended. For insulated mounting, apply the compound to the bottom of both device and insulator. Avoid applying excess compound as the thermal resistance that results can be higher than if no compound is applied. 2.5 Thermal data for TO-220 packages with various heatsink mounting methods The mounting base-to-heatsink thermal resistance R th(mb-h) is package-dependent, not device dependent. It applies to all devices in a given package. The figures given in Table 1 assume optimum mounting conditions (that is flat heatsink, spring clip mounted, optimum quantity of heatsink compound where applicable). However the junction-to-mounting base thermal resistance R th(j-mb) is device-dependent; figures are quoted separately in each data sheet. For full-pack (SOT186A) devices, junction-to-heatsink thermal resistance R th(j-h) with and without heatsink compound are quoted separately in each data sheet. Table 1. Thermal resistance from mounting base to heatsink; R th(mb-h) Mounting method clip screw (K/W) Direct with heatsink compound 0.3 0.5 Direct without heatsink compound 1.4 1.4 With heatsink compound and 0.1 mm maximum mica insulator 2.2 - With heatsink compound and 0.25 mm maximum alumina insulator 0.8 - With heatsink compound and 0.05 mm mica insulator 0.8 - insulated up to 500 V - 1.4 insulated up to 800 V / 1000 V - 1.6 Without heatsink compound and 0.05 mm mica insulator 0.8 - insulated up to 500 V - 3.0 insulated up to 800 V / 1000 V - 4.5 Additional insulators are generally not required when mounting the full-pack (SOT186A) package. 2.6 Soldering Recommendations for devices with a maximum storage temperature rating 175 C: All information provided in this document is subject to legal disclaimers. NXP B.V. 2012. All rights reserved. Application note Rev. 1 29 May 2012 4 of 11

2.6.1 Dip or wave soldering Maximum permissible solder temperature is 260 C at a distance from the body of > 5 mm and for a total contact time with soldering bath or waves of < 7 s. 2.6.2 Hand soldering Maximum permissible temperature is 275 C at a distance from the body of > 3 mm and for a total contact time with the soldering iron of < 5 s. The body of the device must not touch anything with a temperature > 200 C. It is not permitted to solder the metal tab of the device to a heatsink. Avoid any force on body and leads during or after soldering; do not correct the position of the device or of its leads after soldering. 2.7 Lead bending Maximum permissible tensile force on the body for 5 seconds is 20 N. The leads can be bent, twisted or straightened. To keep forces within the above mentioned limits, always clamp the leads rigidly near the body during bending. This prevents damage to the seal of the leads within the plastic body. Leads can be bent as near to the body as required, but allow an adequate length of minimum 1.75 mm from the body to the start of a bend radius for clamping. The internal radius of bend must never be less than the thickness of the lead. A minimum radius of at least 1.5 lead thickness is preferred; see Figure 1. Surface cracks in the plating on the lead are common when a radius less than 1.5 lead thickness is used. Although exposing the copper material, these cracks do not affect the mechanical strength of the lead. clamp area 1.75 min plastic body R> L L aaa-002752 Fig 1. Minimum lead bend radius All information provided in this document is subject to legal disclaimers. NXP B.V. 2012. All rights reserved. Application note Rev. 1 29 May 2012 5 of 11

2.8 Additional guidelines It is recommended that, where a device is rigidly secured to a heatsink which is in turn rigidly secured to a PCB, a bend is formed into the leads to act as an expansion loop. This prevents differential expansion of the mounting parts transferring stress to the soldering joint, as shown in Figure 2. It is only necessary where the device is mounted so rigidly that expansion forces are transmitted through the assembly. rigid rigid secure not rigid rigid solder joint rigid solder joint secure not rigid solder joint PCB PCB PCB (a) incorrect (b) correct (c) correct aaa-002753 Fig 2. Printed-circuit board and heatsink mounting 3. Instructions for clip mounting 3.1 Direct mounting with spring clip 1. Apply heatsink compound to the mounting base, then place the device on the heatsink 2. Push the short end of the clip into the narrow slot in the heatsink with the clip at an angle of 10 to 30 to the vertical; see Figure 3 and Figure 4. 3. Push down the clip over the device until the long end of the clip snaps into the wide slot in the heatsink. The clip must bear on the plastic body, not on the tab; see Figure 5. 4.0 3.8 1 1.6 1.4 12.0 11.5 1.8 min 2.0 1.0 aaa-002754 aaa-002755 aaa-002756 (1) Spring clip. Fig 3. Heatsink requirements Fig 4. Mounting Fig 5. Position of device (top view) All information provided in this document is subject to legal disclaimers. NXP B.V. 2012. All rights reserved. Application note Rev. 1 29 May 2012 6 of 11

3.2 Insulated mounting with spring clip 1. Apply heatsink compound to the bottom of both device and insulator, then place the device with the insulator on the heatsink. 2. Push the short end of the clip into the narrow slot in the heatsink with the clip at an angle of 10 to 30 to the vertical; see Figure 6, Figure 7 and Figure 8. 3. Push down the clip over the device until the long end of the clip snaps into the wide slot in the heatsink. The clip must bear on the plastic body, not on the tab. Ensure that the device is centered on the mica insulator to prevent unwanted movement. 1 4.0 3.8 1.6 1.4 16.8 16.3 1.8 min 2 2.0 1.0 aaa-002757 aaa-002758 aaa-002759 (1) Spring clip. (2) Insulator. Fig 6. Heatsink requirements Fig 7. Mounting Fig 8. Position of device (top view) 4. Instructions for screw mounting 4.1 Direct mounting with screw and spacing washer 4.1.1 Through heatsink with nut M3 bolt washer device Ø 3.5 max heatsink metal plain washer lock washer nut aaa-002760 Ø 3.3 3.1 1.5 min aaa-002761 Fig 9. Assembly Fig 10. Heatsink requirements All information provided in this document is subject to legal disclaimers. NXP B.V. 2012. All rights reserved. Application note Rev. 1 29 May 2012 7 of 11

4.1.2 Into tapped heatsink M3 bolt Ø 3.5 max washer device 4 min tapped heatsink M3 aaa-002762 aaa-002763 Fig 11. Assembly Fig 12. Heatsink requirements 4.2 Insulated mounting with screw and spacing washer Not recommended where mounting tab is at mains voltage. Not applicable to full-pack packages (SOT186A). 4.2.1 Through heatsink with nut M3 bolt washer device insulating washer 15 mm x 19 mm heatsink insulating bush metal plain washer lock washer nut aaa-002764 Fig 13. Insulated screw mounting with washer All information provided in this document is subject to legal disclaimers. NXP B.V. 2012. All rights reserved. Application note Rev. 1 29 May 2012 8 of 11

2.0 ± 0.1 180 120 Ø 4.7 ± 0.1 0.7 ± 0.1 2.0 ± 0.1 Ø 5.5 ± 0.1 1.0 ± 0.1 + 0.2 Ø 3.6 0 + 0.2 Ø 3.6 0 aaa-002765 aaa-002766 Fig 14. Heatsink requirements for 500 V insulation Fig 15. Heatsink requirements for 800 V insulation 4.2.2 Into tapped heatsink M3 bolt washer insulating bush device insulating washer 15 mm x 19 mm tapped heatsink aaa-002767 Fig 16. Insulated screw mounting with washer into tapped heatsink 180 120 4.7 ± 0.1 180 120 5.5 ± 0.1 2.0 ± 0.1 2.0 ± 0.1 5 min 6 min M3 aaa-002768 M3 aaa-002769 Fig 17. Heatsink requirements for 500 V insulation Fig 18. Heatsink requirements for 1000 V insulation All information provided in this document is subject to legal disclaimers. NXP B.V. 2012. All rights reserved. Application note Rev. 1 29 May 2012 9 of 11

5. Legal information 5.1 Definitions Draft The document is a draft version only. The content is still under internal review and subject to formal approval, which may result in modifications or additions. NXP Semiconductors does not give any representations or warranties as to the accuracy or completeness of information included herein and shall have no liability for the consequences of use of such information. 5.2 Disclaimers Limited warranty and liability Information in this document is believed to be accurate and reliable. However, NXP Semiconductors does not give any representations or warranties, expressed or implied, as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information. NXP Semiconductors takes no responsibility for the content in this document if provided by an information source outside of NXP Semiconductors. In no event shall NXP Semiconductors be liable for any indirect, incidental, punitive, special or consequential damages (including - without limitation - lost profits, lost savings, business interruption, costs related to the removal or replacement of any products or rework charges) whether or not such damages are based on tort (including negligence), warranty, breach of contract or any other legal theory. Notwithstanding any damages that customer might incur for any reason whatsoever, NXP Semiconductors aggregate and cumulative liability towards customer for the products described herein shall be limited in accordance with the Terms and conditions of commercial sale of NXP Semiconductors. Right to make changes NXP Semiconductors reserves the right to make changes to information published in this document, including without limitation specifications and product descriptions, at any time and without notice. This document supersedes and replaces all information supplied prior to the publication hereof. Suitability for use NXP Semiconductors products are not designed, authorized or warranted to be suitable for use in life support, life-critical or safety-critical systems or equipment, nor in applications where failure or malfunction of an NXP Semiconductors product can reasonably be expected to result in personal injury, death or severe property or environmental damage. NXP Semiconductors and its suppliers accept no liability for inclusion and/or use of NXP Semiconductors products in such equipment or applications and therefore such inclusion and/or use is at the customer s own risk. Applications Applications that are described herein for any of these products are for illustrative purposes only. NXP Semiconductors makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Customers are responsible for the design and operation of their applications and products using NXP Semiconductors products, and NXP Semiconductors accepts no liability for any assistance with applications or customer product design. It is customer s sole responsibility to determine whether the NXP Semiconductors product is suitable and fit for the customer s applications and products planned, as well as for the planned application and use of customer s third party customer(s). Customers should provide appropriate design and operating safeguards to minimize the risks associated with their applications and products. NXP Semiconductors does not accept any liability related to any default, damage, costs or problem which is based on any weakness or default in the customer s applications or products, or the application or use by customer s third party customer(s). Customer is responsible for doing all necessary testing for the customer s applications and products using NXP Semiconductors products in order to avoid a default of the applications and the products or of the application or use by customer s third party customer(s). NXP does not accept any liability in this respect. Export control This document as well as the item(s) described herein may be subject to export control regulations. Export might require a prior authorization from competent authorities. Evaluation products This product is provided on an as is and with all faults basis for evaluation purposes only. NXP Semiconductors, its affiliates and their suppliers expressly disclaim all warranties, whether express, implied or statutory, including but not limited to the implied warranties of non-infringement, merchantability and fitness for a particular purpose. The entire risk as to the quality, or arising out of the use or performance, of this product remains with customer. In no event shall NXP Semiconductors, its affiliates or their suppliers be liable to customer for any special, indirect, consequential, punitive or incidental damages (including without limitation damages for loss of business, business interruption, loss of use, loss of data or information, and the like) arising out the use of or inability to use the product, whether or not based on tort (including negligence), strict liability, breach of contract, breach of warranty or any other theory, even if advised of the possibility of such damages. Notwithstanding any damages that customer might incur for any reason whatsoever (including without limitation, all damages referenced above and all direct or general damages), the entire liability of NXP Semiconductors, its affiliates and their suppliers and customer s exclusive remedy for all of the foregoing shall be limited to actual damages incurred by customer based on reasonable reliance up to the greater of the amount actually paid by customer for the product or five dollars (US$5.00). The foregoing limitations, exclusions and disclaimers shall apply to the maximum extent permitted by applicable law, even if any remedy fails of its essential purpose. Translations A non-english (translated) version of a document is for reference only. The English version shall prevail in case of any discrepancy between the translated and English versions. 5.3 Trademarks Notice: All referenced brands, product names, service names and trademarks are the property of their respective owners. All information provided in this document is subject to legal disclaimers. NXP B.V. 2012. All rights reserved. Application note Rev. 1 29 May 2012 10 of 11

6. Contents 1 Introduction............................ 3 2 General data and instructions............. 3 2.1 General rules.......................... 3 2.2 Mounting methods...................... 3 2.2.1 Clip mounting.......................... 3 2.2.2 M3 screw mounting..................... 3 2.2.3 Rivet mounting non-insulated.............. 3 2.3 Heatsink requirements................... 4 2.4 Heatsink compound..................... 4 2.5 Thermal data for TO-220 packages with various heatsink mounting methods......... 4 2.6 Soldering............................. 4 2.6.1 Dip or wave soldering.................... 5 2.6.2 Hand soldering......................... 5 2.7 Lead bending.......................... 5 2.8 Additional guidelines..................... 6 3 Instructions for clip mounting............. 6 3.1 Direct mounting with spring clip............ 6 3.2 Insulated mounting with spring clip.......... 7 4 Instructions for screw mounting........... 7 4.1 Direct mounting with screw and spacing washer............................... 7 4.1.1 Through heatsink with nut................. 7 4.1.2 Into tapped heatsink..................... 8 4.2 Insulated mounting with screw and spacing washer............................... 8 4.2.1 Through heatsink with nut................. 8 4.2.2 Into tapped heatsink..................... 9 5 Legal information....................... 10 5.1 Definitions............................ 10 5.2 Disclaimers........................... 10 5.3 Trademarks........................... 10 6 Contents.............................. 11 Please be aware that important notices concerning this document and the product(s) described herein, have been included in section Legal information. NXP B.V. 2012. All rights reserved. For more information, please visit: http://www.nxp.com For sales office addresses, please send an email to: salesaddresses@nxp.com Date of release: 29 May 2012 Document identifier: