CHECKFIRE 110 DETECTION AND ACTUATION SYSTEM

Similar documents
CHECKFIRE 210 Detection and Actuation System

CHECKFIRE 110 DETECTION AND ACTUATION SYSTEM

User Operation Manual

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

REPEATER FS5200R OPERATION MANUAL

Installation, Operating and Maintenance Manual

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

Intelligent Security & Fire Ltd

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

CSP-204 CSP-208 CSP-104 CSP-108

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Conventional Fire Alarm System 2014 V1.2

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

Racal-Guardall. Countess. User Instructions. Countess

SECURIT 700L USER MANUAL

Tomorrow s technology for today s security needs.

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual

Excel-EN Conventional Fire Control Panel

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

GAS SUPRESSION CONTROL PANEL:

Fire Command Keypad. XR5 User s Guide

NetworX NX-8V2. LED Keypad User Manual

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Operation & Maintenance Manual

EXTINGUISHING AGENT RELEASE MODULE

NX-148 LCD CODE PAD TABLE OF CONTENTS

Temporary wireless battery operated fire system from Channel Safety Systems

HILLS Series LED Code Pad User Manual

U ser's Guide PC6010

SFC-200 SERIES LED FIRE ALARM PANEL

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Safewatch Pro 3000 System Manual

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

ZSC100 Gas Detection and Alarm System Controller

MOBILE CALL GSM Alarm System User s Manual

SECURIT 703 USER MANUAL

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

ID2000. operating manual

HILLS Series LCD Code Pad User Manual

Control Panel Engineering and Commissioning Instructions

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

SALES SUPPORT DOCUMENT

Doc. No Part No Rev. U * T*

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Functional Performance Test

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Control/Communicator Installation Manual

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

5 Sounds and Indications

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Intruder alarm system Operating Instructions

Typical Applications: Excavators Haul Trucks Wheeled Loaders Drag Lines Large Dozers Drills

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

NETWORX TM. User manual NX-4

Simon XTi Quick Operation Guide

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

Service manual. Type: TD25. Contents

SUPERIOR THINKING. DEEPER DIGGING. Underground Mining Fire Suppression Systems

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Remote NAC Power Supply D7038

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Quick Reference Guide

Installation Instructions

Specification/ Data Sheet

Note: The buttons on the wireless key fob are sensitive. Kindly handle the fobs with care to avoid false alarms.

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

MR-2602 Two Zone Fire Alarm Control Panel

NetworX Series NX-1500E LED Keypad

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Service Bulletin No. 2930

Accenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

**** **** A B ARMED FIRE FIRE C D READY OFF AWAY STAY 2 3 MAXIMUM TEST BYPASS PULL INSTANT CODE CHIME. First Alert READY. * 0 # Professional

SECURITY SYSTEM NOTES

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

MODEL B2 INSTALLATION MANUAL

FA-300 Series. LED Fire Alarm Control Panel. User Guide. FA-300 SERIES Fire Alarm Control Panel. FA-300 SERIES Fire Alarm Control Panel

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax:

VISTA-32FBPT. Commercial Fire and Burglary Partitioned Security Systems with Scheduling. User Guide /12 Rev. B

Property of Monitronics Inc

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

Fire Alarm Control Panel. System Maintenance and Log Book

Sigma XT. Extinguishant Control Panel. User Manual Man-1091 Issue 03 October 2009 (K11031M2, K11031F2)

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Document No Issue 4 user manual

Remote Chexit Module (RCM) System. General Information

VISTA-50P VISTA-50PUL

Michigan State University Construction Standards FIRE DETECTION AND ALARM PAGE

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

Installation Manual Premier 412/816/832. Issue 10

D1265. User's Guide. Touchscreen Keypad

Transcription:

CHECKFIRE 110 DETECTION AND ACTUATION SYSTEM OWNERS GUIDE 2017 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Part No. 442044-03

CHECKFIRE 110 Detection and Actuation System Owners Guide CONTROL MODULE DELAY/RESET/ SILENCE BUTTON VISUAL SEAL 009151 PUSH TO ACTIVATE/ ALARM WHEN LIT BUTTON AND LED This vehicle/equipment is monitored with a CHECKFIRE 110 Detection and Actuation System which is typically connected to an ANSUL A-101 or LVS Fire Suppression System for 24-hour fire suppression. The operator of the equipment should be provided with hands-on training by Authorized ANSUL Distributors or the end user. This handbook is a quick-reference guide for basic operation of the CHECKFIRE 110 system. Two buttons on the control module and manual actuators provide operator control. Fill-In System Information (as installed) External Power Supply (vehicle battery, power panel, etc.): Note: Internal backup power provides approximately 72 hours of power during normal operating conditions. Selected Time Delay Period (seconds): h 5 h 15 Pressure Switch Auxiliary Operation: PAGE 1

IN CASE OF FIRE: Manual Actuation OPEN GUARD DOOR 009241 PUSH RED BUTTON FOR IMMEDIATE ACTIVATION 1) Safely bring equipment to complete stop, set brake and shut off engine. 2) Break visual seal and open guard door. 3) Push the red PUSH To Activate / Alarm When Lit button. 4) Release circuit immediately activates the connected fire suppression system (if included, pressure switch activates auxiliary operation). See Note below. 5) Safely exit equipment and stand-by with supplemental firefighting equipment. 6) Optional manual actuation: Pull ring pin and strike red button on electric or pneumatic manual actuator. Note: The red PUSH To Activate / Alarm When Lit LED and sounder remain steady-on for 10 sec. during initiation (release) of fire suppression system. Post release: PUSH To Activate/ Alarm When Lit and Release LEDs and sounder continue to pulse 1 x 10 sec. If safe to re-enter equipment, push DELAY/ Reset/Silence button to silence sounder for two hours. Fill-In System Information (as installed) Electric or Pneumatic Manual Actuator Location(s): PAGE 2

IN CASE OF FIRE: Automatic System Operation 1) Detector(s) registers alarm condition in the hazard area and initiates the time delay on the control module. 2) PUSH To Activate / Alarm When Lit LED and sounder: a. Pulse 2 x 1 sec. until last 5 sec. of Time Delay; then pulse 4 x 1 sec. during final 5 sec. To restart time delay press and release DELAY/RESET/SILENCE (Grey) button (see below for more information). b. After time delay, PUSH To Activate / Alarm When Lit LED and sounder are steady-on for 10 sec. during initiation (release) of fire suppression system (if included, pressure switch activates auxiliary functions). 3) As soon as time delay begins: Safely stop equipment, set brake, shut off engine, and exit. Standby with supplemental firefighting equipment. PUSH GREY BUTTON TO RESTART TIME DELAY 009180 DELAY/RESET/SILENCE (Grey) Button 1) Restart Time Delay: Press and release to restart the time delay cycle during alarm condition. a. Must be initiated before release circuit activates. b. Note: Press and hold will not extend time delay period. 2) Silence sounder (post discharge or fault notification) for two hours: Press and release to silence sounder; LED fault indication will continue until fault is cleared. Any new fault or detection event will reactivate sounder. 3) Reset function is for Authorized ANSUL Distributor service technician. PAGE 3

FRONT PANEL INDICATORS POWER LED: GREEN, AMBER OR OFF 009180 RELEASE FAULT LED: OFF OR AMBER DETECTION FAULT LED: OFF OR AMBER 1) Power LED a. Green steady-on indicates normal external power. b. Amber pulsing 1 x 30 sec. indicates external power fault; Sounder auto-silences after 10 min. to conserve power. Amber pulsing 1 x 10 sec. indicates internal power fault; sounder auto-silences after 10 min. to conserve power. Power fault will continue for up to 72 hours as long as fault exists or until unit powers down. Contact Authorized ANSUL Distributor for service. c. Off indicates no system power. 2) Release! and Detection Fault LEDs a. Off indicates normal status. b. Amber pulsing with sounder indicates a fault condition. CAUTION Any fault indication may cause the fire detection and actuation system to not function properly; immediately contact an Authorized ANSUL Distributor for service. PAGE 4

FRONT PANEL INDICATORS (Continued) 3) Red PUSH To Activate / Alarm When Lit LED (sounder matches pulse rate). a. Pulsing 2 x 1 sec. indicates Alarm Condition and time delay starts countdown (last 5 sec. pulsing increases to 4 x 1 sec.). b. Steady-on for 10 sec. indicates Release Activated. c. Pulsing 1 x 10 sec. indicates Post Release Activated. d. LED is also a button, see page 2 for manual activation of fire suppression system. 4) DELAY/Reset/Silence Button a. Icons on button represent options for system control. During Time Delay, press button to restart Time Delay. When sounder is pulsing, press button to silence. Press and hold button for 3 sec. to reset system. PAGE 5

PAGE 6