Bulletin ZC05 ZEPHYR CABINET FANS. Models: ZC, ZCC Single and Twin Unit Belt Drive Cabinet Fans

Similar documents
Bulletin FH05 FUME EXHAUST

Selecting the Correct Fan

MXI Mixed Flow Inline Fan

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

Fans: Features and Analysis

Understanding Fan System Effects

Introduction to Fans. The Basics of Fan Principles and Terminology

Glossary of Terms Laboratory & Fume Exhaust Fans

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Product Handbook. Moving Your Way. Our Complete Product Offering. PennBarry Manufacturer of Ventilation Products

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Fan Selection. and Energy Savings

ENGINEERING LETTER 4

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Indirect Gas-Fired Make-Up Air

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

A. Codes and Standards that are Standard at the University:

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

M Series Fan Filter Units

SECTION AXIAL FANS

DBF 4XL Dryer Booster Fans

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

SECTION (15833) - HVAC POWER VENTILATORS

Plenum Fans. Model HPA. Direct Drive

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

PRODUCT HANDBOOK A Complete Product Overview

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Twin City Fan & Blower

e Bath Fan with Light User s Guide

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

Modular Supply Make-Up Air Unit

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

RP, GP, XP Pro Series Installation Instructions

Product Specifications. Vertical Floor Consoles By First Co.

Direct Gas-Fired Make-Up Air

5 year fan housing and motor warranty

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

INFRARED RADIANT HEATERS

Easy installation in both new construction and retrofit

KIC Air Curtains. Technical Guide

F116 (Series 16000) Self-Contained Ductable Commercial Air Cleaner

ZEPHYR Ceiling Exhaust Fans

CML Northem Blower Inc. Air Movement Equipment

FAN WALL Technology. Product

e Bath Fan with Light User s Guide

ZEPHYR Ceiling Exhaust Fans

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

Submittal Data Performance Data Electrical Data

City of Duluth Festival Center 04/25

Installation & Maintenance Instructions

User s Manual and Operating Instructions

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

Twin City Fan & Blower

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

e Bath Fan with Light User s Guide

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Fuji Electronic VFC 084P-5T

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Direct Fired Heater Model AD Specification

Easy installation in both new construction and retrofit

Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07

IN020 Rev F Page 1 of 8

PDH & Professional Training

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

MODEL CDB8 INSTALLATION INSTRUCTIONS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Bathroom Exhaust Fan

GreenJet Transfer Fans

Insulated Ventilators. Operating Instructions & Parts Manual

Industrial Fans & Blowers

INDOOR, SUSPENDED, STEAM OR HOT WATER HYDRONIC UNIT HEATER FOR VERTICAL OR HORIZONTAL CONFIGURATION

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

User s Manual and Operating Instructions

CVS Model Inline Multi-Port Ventilators

MPA Modular Plenum Array Installation, Operation, and Maintenance Manual

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Electric Radiator. A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw

Evaluation Report 509

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

READ AND SAVE THESE INSTRUCTIONS

Static Pressure Alarm For Hazardous Location Fume Hoods

Installation & Maintenance Instructions

MH70230AS MH70236AS MH70248AS

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

Design Criteria. Installation

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

Fan Array Systems WHITE PAPER. Rad Ganesh, PhD, P.E. Director, R&D / Applications Twin City Fan Companies, Ltd. Minneapolis, MN, United States

Fan Arrays. White Paper. Energy Labs White Paper Series Volume 0412 Issue 001 April 2012 Rev. 0. Series

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Transcription:

Bulletin ZC05 ZEPHYR CABINET FANS Models: ZC, ZCC Single and Twin Unit Belt Drive Cabinet Fans

ZC & ZCC Introduction CERTIFIED RATINGS PennBarry certifies that the Zephyr ZC and ZCC models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Standard 211 and comply with the requirements of the AMCA Certified Ratings Program. Visit Our Web Site Point your internet web browser to www.pennbarry.com for up-to-the-minute information including: On-line catalog List of nearest PennBarry representatives What s New HVAC Hot Links Table of Contents Introduction..................................1 Features and Benefits......................... 2 Options and Accessories.......................3 Performance Data............................5 Engineering Notes............................9 Sample Specifications...................... 13 Limited Warranty............................ 14 FANSIZER Product Selection Software FanSizer software allows you to select the best centrifugal or axial unit for your application. Input and static pressure, and FanSizer will make the optimum selection. It allows you to complete job schedules which you can store, modify and print in seconds. Features include: on-line help, on-screen product drawings and dimensions, and complete text specifications. In addition, you can convert job schedules to ASCII code for use with other programs like word processing. FANCAD Library of CAD Drawings FanCad is a library of drawings for use with computer-aided design (CAD) systems. FanCad s pre-drawn details can save hours of drafting time. Included are all popular PennBarry fans and related items. FanSizer and FanCad are registered trademarks. 2005 PennBarry All rights reserved. Following publication of this catalog changes may have been made in standard equipment, options and the like that would not be included. We reserve the right to make changes at any time, without notice, to models, specifications, options, availability, etc. This bulletin illustrates the appearance of PennBarry products at the time of publication and we reserve the right to make changes in design and construction at anytime without notice. Your local sales representative is the best source for current information. PENNBARRY 1

Features and Benefits Belt Drive Units offered with belt drive motors to allow maximum adjustability. Internal Motor and Drive Assembly The motor and drive assembly are located inside of the unit for safety. This design also cools the motor so the unit will run more efficiently. Ball Bearing Motor Zephyr Cabinet fans utilize ball bearing motors for durability and long life. Blower Shaft Ball Bearings The blower shaft rides on ball bearings for quiet operation. PennBarry Zephyr series ZC belt drive cabinet fans are general purpose duct blowers. These versatile, quiet operating air movers provide economical, convenient and effective ventilation in ducted systems. They are also used extensively in heating and cooling systems. Four sizes cover an air capacity range up to 6350. ZC units are sized with space saving in mind and furnished with inlet and outlet connecting flanges and side access panels as standard. Optional accessories include a duct mounted filter assembly. Easy Access Side Panels Zephyr Cabinet fans come with dual side panels. These panels are easily removable which allows for installation flexibility. Application Versatility Zephyr Cabinet fans are available in supply or exhaust. Typical Applications Zephyr ZC and ZCC Cabinet fan units are versatile in application. They may be used in ventilation, recirculation, and air conditioning systems as typified by the illustrations on page 12. Dampers, inlet/outlet air diffusers/grilles, cooking appliances, air conditioning coils and ducting shown are typically furnished by others but in part may be available from PennBarry. Models ZCC are Dual Units The twin assembly doubles the capacity of a single unit for the same static pressure with identical. Two similar motors are used which enables the flexibility of independent operation when desired. 2 PENNBARRY

Options and Accessories Acoustically Insulated Housing Optional insulation to line housing for acoustic sensitive applications. Guards Zephyr Cabinet fans can be supplied with inlet and outlet guards for safety. Vibration Isolation Zephyr Cabinets fans can be supplied with vibration hangers. Vibration hangers allow the fan to be isolated from the building structure which prevents any building resonance from being transmitted to the fan housing. Safety Disconnect Switch Standard safety disconnect switches include a wiring harness connected to the motor and terminating at a junction box under the motor dome. Final wiring to the switch is by field electrician. This on/off type switch is available for all ODP single and three phase motors. Outdoor and explosion proof DS are generally too large to install under the motor dome, and will be shipped loose for field mounting and wiring. Internal Wiring NEMA 3R wiring is available for both direct and belt drive models. ZF Filter Series ZF filters are designed for compatibility with Zephyr series ZC cabinet fans. ZF filters can be close-coupled to ZC unit inlets or installed remote to the ZC in the system ductwork. The compact design and ease of maintenance also make ZF filters an ideal choice as a standard duct filter. The filter media can be easily cleaned and is washable with plain soap and water. The pull-out drawer action provides quick and easy access. One filter is required for Model ZC and two filters for Model ZCC. D ZF Filter Dimensions E C A SIZE A B C D E ZF1 22 1/4 20 20 1/8 17 7/8 5 3/4 ZF2 27 23 24 7/8 20 7/8 5 3/4 ZF3 33 1/2 28 30 1/4 24 3/4 5 3/4 ZF4 42 34 38 5/8 30 5/8 5 3/4 C B D ALL DIMENSIONS IN INCHES. PENNBARRY 3

ZC - Dimensional Data Zephyr Cabinet Fan K L F E M Top G G INLET END A 1 1 TOP ACCESS PANEL P J F C D Q R B OUTLET END H SIDE Dimensions OUTLET INLET ACCESS OPENING MODEL A B C D E F G H J K L M P Q R ZC10 24 3/4 22 1/4 20 11 3/8 13 3/8 18 1/8 20 3/8 17 1/4 18 1 5/8 13 3/8 17 1/2 11 1/8 7 3/8 1 5/ 8 ZC12 27 1/2 27 23 13 1/2 15 5/8 21 1/8 25 1/8 20 21 1 5/8 16 1/8 21 13 1/2 8 1/8 1 3/ 8 ZC15 32 33 1/2 28 15 7/8 18 5/8 25 30 1/2 24 1/2 26 1 1/2 19 1/2 23 16 3/4 10 5/8 2 5/ 8 ZC18 43 42 34 18 7/8 21 7/8 31 39 35 1/2 30 1 7/8 24 37 21 13 3 5/ 8 Dimensions are approximate and may vary slightly due to manufacturing tolerances. All dimensions in inches. 4 PENNBARRY

Performance Data - ZC 10, 12, 15, 18 Approximate Sone Level Ranges Up to 9. 9.1 to 13. 13.1 to 18. 18.1 to 50. ZC 10 Inlet Area (FT 2 )=2.56 Outlet Area (FT 2 )=1.04 Outlet Velocity (FPM)=/1.04 Tip Speed (FPM)=2.78x Wheel Dia.=10 5/8" 750 950 1150 1350 1550 1750 1950 0.125 S.P. 396 431 473 519 568 620 677 0.04 0.06 0.10 0.14 0.19 0.27 0.36 0.250 S.P. 523 545 573 611 652 697 743 0.07 0.10 0.14 0.19 0.25 0.32 0.41 0.375 S.P. 627 643 665 694 728 768 810 0.11 0.14 0.18 0.23 0.30 0.38 0.48 0.500 S.P. 731 747 772 800 833 873 0.18 0.22 0.28 0.35 0.44 0.55 0.625 S.P. 796 824 841 868 897 930 0.20 0.28 0.32 0.41 0.5 0.61 0.750 S.P. 863 882 905 931 959 987 0.23 0.29 0.37 0.46 0.57 0.68 1.000 S.P. 1002 1021 1044 1069 1097 0.38 0.46 0.57 0.68 0.82 1.250 S.P. 1126 1146 1176 1195 0.57 0.67 0.84 0.95 1.500 S.P. 1221 1240 1262 1291 0.67 0.78 0.92 1.12 ZC 12 Inlet Area (FT 2 )=3.69 Outlet Area (FT 2 )=1.47 Outlet Velocity (FPM)=/1.47 Tip Speed (FPM)=3.31x Wheel Dia.=12 5/8" 1150 1350 1550 1750 1950 2150 2350 2550 2750 0.125 S.P. 339 359 381 406 432 459 486 516 547 0.08 0.10 0.13 0.18 0.23 0.28 0.35 0.43 0.52 0.250 S.P. 443 456 472 492 511 533 559 584 611 0.13 0.16 0.2 0.25 0.30 0.36 0.45 0.54 0.64 0.375 S.P. 529 538 552 565 583 603 623 643 668 0.19 0.22 0.27 0.32 0.38 0.46 0.54 0.62 0.74 0.500 S.P. 612 621 634 648 664 683 703 7 23 0.30 0.34 0.40 0.47 0.54 0.63 0.74 0.85 0.625 S.P. 680 685 695 709 722 737 756 776 0.38 0.42 0.49 0.56 0.64 0.73 0.84 0.96 0.750 S.P. 747 752 764 777 791 806 825 0.52 0.57 0.65 0.74 0.84 0.95 1.08 1.000 S.P. 853 866 876 889 902 916 0.75 0.86 0.95 1.07 1.19 1.32 1.250 S.P. 954 964 975 989 1002 1.01 1.16 1.29 1.43 1.58 1.500 S.P. 1045 1056 1067 1080 1.38 1.52 1.67 1.84 ZC 15 Inlet Area (FT 2 )=5.30 Outlet Area (FT 2 )=2.05 Outlet Velocity (FPM)=/2.05 Tip Speed (FPM)=3.93x Wheel Dia.=15" 1950 2350 2750 3150 3550 3950 4350 4750 0.125 S.P. 303 331 361 393 425 465 505 547 0.13 0.19 0.26 0.37 0.51 0.68 0.89 1.14 0.250 S.P. 385 406 428 455 485 515 547 580 0.19 0.27 0.35 0.47 0.61 0.77 0.99 1.25 0.375 S.P. 452 470 490 512 536 565 594 625 0.26 0.35 0.45 0.57 0.72 0.91 1.12 1.37 0.500 S.P. 512 526 544 565 587 610 637 666 0.34 0.43 0.55 0.69 0.85 1.04 1.26 1.52 0.625 S.P. 575 594 612 633 655 678 704 0.51 0.64 0.79 0.97 1.18 1.41 1.68 0.750 S.P. 622 639 657 675 697 719 742 0.59 0.74 0.91 1.09 1.31 1.56 1.84 1.000 S.P. 724 736 754 773 793 815 0.96 1.12 1.34 1.59 1.86 2.17 1.250 S.P. 810 824 843 861 881 1.36 1.59 1.87 2.16 2.50 1.500 S.P. 888 906 924 943 1.83 2.14 2.47 2.83 ZC 18 Inlet Area (FT 2 )=8.40 Outlet Area (FT 2 )=2.87 Outlet Velocity (FPM)= / 2.87 Tip Speed (FPM)=4.75x Wheel Dia.=18 1/8" 3150 3550 3950 4350 4750 5150 5550 5950 6350 0.125 S.P. 369 391 415 440 466 0.63 0.77 0.94 1.14 1.37 0.250 S.P. 402 420 439 458 479 501 0.65 0.79 0.95 1.12 1.32 1.55 0.375 S.P. 436 452 468 484 502 521 540 0.65 0.79 0.94 1.11 1.30 1.53 1.77 0.500 S.P. 462 478 495 511 527 543 559 577 0.66 0.78 0.92 1.09 1.28 1.49 1.71 1.97 0.625 S.P. 503 516 532 549 565 581 597 613 0.79 0.92 1.07 1.24 1.43 1.66 1.91 2.18 0.750 S.P. 552 567 583 599 616 631 647 1.05 1.22 1.40 1.60 1.83 2.09 2.38 1.000 S.P. 629 643 659 675 692 708 1.51 1.71 1.95 2.19 2.47 2.75 1.250 S.P. 700 713 729 745 761 2.05 2.29 2.57 2.87 3.19 1.500 S.P. 765 778 793 809 2.65 2.94 3.26 3.61 PENNBARRY 5

ZCC - Dimensional Data Zephyr Cabinet Fan ZCC Belt Drive Twin Assembly Models ZCC are dual units. The twin assembly doubles the capacity of a single unit for the same static pressure with identical. Two similar motors are used which enables the flexibility of independent operation when desired. X ACCESS PANEL Y C ACCESS PANEL SUPPORT CHANNELS B D JOINER ANGLE E W OPTIONAL VIBRATION ISOLATORS (4 REQ D) E Y V G C S U T G HANGER RODS (BY OTHERS) F INLET DUCT FLANGE B W B OUTLET DUCT FLANGE B A ACCESS DOOR (EACH SIDE) INLET END - DUAL UNIT Dimensions OUTLET INLET Model A B C W D E Z F G U Y V S T X ZCC10 24 3/4 22 1/4 20 45 11 3/8 13 1/8 9 5/8 18 1/8 20 1/8 2 3/8 50 1/2 48 1/2 1 5/8 13 3/8 1 ZCC12 27 1/2 27 23 54 1/2 13 1/2 15 5/8 11 7/8 21 1/8 25 1/8 2 3/8 60 58 1 5/8 16 1/8 1 ZCC15 32 33 1/2 28 67 1/2 15 7/8 18 5/8 15 3/8 25 30 1/2 3 1/2 73 71 1 1/2 19 1/2 1 ZCC18 43 42 34 84 1/2 18 7/8 21 7/8 20 5/8 31 39 3 1/2 90 88 1 7/8 24 1 6 PENNBARRY

Performance Data - ZCC 10, 12, 15, 18 Approximate Sone Level Ranges 1500 1900 2300 2700 3100 3500 3900 Up to 9. 9.1 to 13. 13.1 to 18. 18.1 to 50. 50+. ZCC 10 Inlet Area (FT 2 )=5.12 Outlet Area (FT 2 )=2.08 Outlet Velocity (FPM)= / 2.08 Tip Speed (FPM)=2.78x Wheel Dia.=10 5/8" 0.125 S.P. 396 431 473 519 568 620 677 0.08 0.13 0.19 0.28 0.39 0.53 0.71 0.250 S.P. 523 545 573 611 652 697 743 0.14 0.20 0.27 0.37 0.49 0.65 0.83 0.375 S.P. 627 643 665 694 728 768 810 0.22 0.27 0.35 0.46 0.60 0.77 0.96 0.500 S.P. 731 747 772 800 833 873 0.37 0.44 0.56 0.71 0.88 1.10 0.625 S.P. 796 824 841 868 897 930 0.40 0.55 0.65 0.81 1.01 1.23 0.750 S.P. 863 882 905 931 959 987 0.47 0.59 0.74 0.92 1.13 1.36 1.000 S.P. 1002 1021 1044 1069 1097 0.76 0.93 1.13 1.36 1.63 1.250 S.P. 1126 1146 1176 1195 1.13 1.34 1.67 1.89 1.500 S.P. 1221 1240 1262 1291 1.34 1.57 1.84 2.24 ZCC 12 Inlet Area (FT 2 )=7.38 Outlet Area (FT 2 )=2.94 Outlet Velocity(FPM)= / 2.94 Tip Speed (FPM)=3.31x Wheel Dia.=12 5/8" 2300 2700 3100 3500 3900 4300 4700 5100 5500 0.125 S.P. 339 359 381 406 432 459 486 516 547 0.15 0.20 0.27 0.35 0.45 0.57 0.70 0.86 1.05 0.250 S.P. 443 456 472 492 512 533 559 585 611 0.26 0.32 0.40 0.49 0.60 0.73 0.89 1.08 1.28 0.375 S.P. 529 538 552 565 584 603 623 643 668 0.38 0.45 0.54 0.64 0.77 0.91 1.07 1.25 1.48 0.500 S.P. 612 621 634 648 664 683 703 723 0.60 0.69 0.81 0.94 1.09 1.27 1.47 1.69 0.625 S.P. 680 685 696 709 723 738 757 776 0.76 0.85 0.98 1.12 1.29 1.47 1.69 1.93 0.750 S.P. 747 752 764 778 791 806 825 1.04 1.15 1.31 1.49 1.68 1.89 2.16 1.000 S.P. 854 866 876 889 903 916 1.51 1.71 1.90 2.13 2.38 2.64 1.250 S.P. 954 964 976 989 1002 2.10 2.33 2.58 2.87 3.17 1.500 S.P. 1046 1056 1067 1081 2.78 3.05 3.35 3.70 ZCC 15 Inlet Area (FT 2 )=10.60 Outlet Area (FT 2 )=4.10 Outlet Velocity(FPM)= / 4.10 Tip Speed (FPM)=3.93x Wheel Dia.=15" 3900 4700 5500 6300 7100 7900 8700 9500 0.125 S.P. 303 331 361 393 425 465 505 547 0.44 0.52 0.54 0.75 1.01 1.36 1.77 2.28 0.250 S.P. 385 406 429 456 485 516 547 580 0.39 0.74 1.26 1.46 1.49 1.56 1.98 2.50 0.375 S.P. 452 470 490 513 536 565 594 625 0.52 0.70 1.13 1.86 2.64 2.70 2.74 2.79 0.500 S.P. 512 526 544 565 587 610 637 666 0.68 0.86 1.09 1.69 2.64 3.72 4.12 4.19 0.625 S.P. 562 575 594 612 633 655 678 704 0.81 1.01 1.29 1.59 2.44 3.62 4.96 5.72 0.750 S.P. 623 639 657 675 697 719 742 1.19 1.48 1.81 2.18 3.42 4.85 6.46 1.000 S.P. 724 736 754 773 793 815 1.91 2.24 2.69 3.17 4.32 6.13 1.250 S.P. 795 810 824 843 861 881 2.27 2.72 3.17 3.74 4.33 5.44 1.500 S.P. 875 888 906 924 943 3.15 3.65 4.28 4.94 5.67 ZCC 18 Inlet Area (FT 2 )=16.80 Outlet Area(FT 2 )=5.74 Outlet Velocity(FPM)= / 5.74 Tip Speed (FPM)=4.75x Wheel Dia.=18 1/8" 6300 7100 7900 8700 9550 10300 11100 11900 12700 0.125 S.P. 370 391 415 440 466 1.28 1.55 1.88 2.28 2.74 0.250 S.P. 402 421 439 458 479 501 1.31 1.60 1.89 2.24 2.64 3.11 0.375 S.P. 436 452 469 484 502 521 540 1.30 1.58 1.91 2.23 2.62 3.06 3.54 0.500 S.P. 462 479 495 512 527 543 559 577 1.32 1.58 1.85 2.20 2.56 2.98 3.44 3.95 0.625 S.P. 503 516 532 550 565 581 597 613 1.58 1.83 2.14 2.51 2.86 3.33 3.83 4.37 0.750 S.P. 552 567 584 599 616 631 647 2.11 2.44 2.83 3.21 3.65 4.18 4.77 1.000 S.P. 629 644 659 675 692 709 3.02 3.45 3.89 4.39 4.94 5.53 1.250 S.P. 701 713 729 745 761 4.12 4.57 5.14 5.74 6.39 1.500 S.P. 765 778 793 809 5.30 5.87 6.52 7.23 Performance shown is for installation Type B free inlet Ducted Outlet. Performance ratings do not include the effects of appurtenances in the airstream. Power rating () includes drive losses. PENNBARRY 7

Sound Data Notes SOUND POWER LEVELS Since any mechanical device generates some sound energy into the air, fans will create some noise. Because of the great number of factors influencing sound output it is invalid to compare fans based on, tip speed or outlet velocity. The only accurate basis of comparison is the sound power level generated by the fan at the required point of operation. Having sound power levels for a specific fan at a specific operating point allows the system designer to determine the theoretical sound pressure level at any point in the occupied space. AMCA Publication 303 and the ASHRAE Guides provide more information on this process. Another typical application of sound power levels is to compare similar fans. Generally differences of 6 db in the 63 Hz band and 3 db in all other bands are considered insignificant. System designers use many methods to predict acoustic acceptability of an occupied space. The A-weighted sound pressure level provides a single number that corresponds well to the human judgement of relative loudness. OSHA bases their requirements regarding exposure to noise on A-weighted sound pressure levels. The disadvantage of this method is that A-weighted sound pressure levels do not provide information as to the quality of the sound. Noise Criteria (NC) curves are also widely used. To determine the NC level, the sound power spectrum is compared to defined limits. Other methods include RC curves, Sones, SIL and Noise Rating Curves. Each method relies on sound pressure level information because the human ear hears sound pressure fluctuations, not sound power (watts). Sound pressure is a function of the Sound Classification Guide attenuation of the space and the distance from the source. Consider a 100 watt light bulb. It provides adequate light for a closet, but not for a classroom, and in a stadium it would be imperceptible. While the light source was the same power (100 watts), the brightness level changed dramatically. Similarly, the same sound power level (acoustical energy) produces greatly different sound pressure levels (noise). Sone Ratings PennBarry has provided sone ratings to allow designers to make an educated judgment as to the noise level a fan will develop in a space. Sone ratings are a loudness index developed from sound power level data. The calculation is at 5' from the fan inlet and in front of a reflecting plane (hard wall). Sones are weighted similarly to the A-weighting scale in that more weight is given to frequencies that people can hear well and less weight to frequencies that people do not hear well. A significant feature of the sone scale is that it is linear rather than logarithmic. This means that 40 sones is 33% louder than 30 sones, as opposed to 40 db being twice as loud as 30 db. Since the sone rating is determined from well defined assumptions and is linear in nature, it is ideal for comparing different fans moving air at the same and SP. When using sones for this purpose, differences of 3 sones are considered negligible. The suggested loudness level chart below is a practical guideline for acceptable installed performance. The sone values shown in this catalog are based on the sound power levels determined above, and calculated in accordance with AMCA Standard 301 Methods for Calculating Fan Sound Ratings from Laboratory Test Data. SUGGESTED LOUDNESS LEVEL AREA SONE LEVEL NOISE CRITERIA NC dba (1) TYPES OF AREAS Up to 9 32 to 54 35 to 60 9.1 to 13 55 to 59 61 to 65 13.1 to 18 60 to 64 66 to 70 18.1 to 50 65 to 78 71 to 84 Bingo Hall, Auction Room, Hotel Ballroom, Social Club, Reception Room, Apartment House, Professional Office, Supervisor Office, Courtroom, School and Classroom, Hospital Ward, Operating Room, Correction Facility. Lobby/Corridor, Spectator Area, Chicken House, Greenhouse, General Open Office, Restaurant, Night Club, Department Store, Ticket Sales Office, Casino, Spa, Control Room, Rail, Bus, Plane, Bowling Alley, Print Shop, Drafting Office, Convention Hall Washroom & Toilet, Retail Shop, Bus Terminal Lounge, Foreman's Office, Cocktail Lounge, Office Hall & Corridor, Tabulation & Computation Office, Kitchen Cafeteria, Hotel Garage, Computer Room, Warehouse, Battery Charging Room General Storage Area, Restaurant Banquet Room, Swimming Pool, Supermarket, Hotel Kitchen and Laundry, Welding Booth, Department Store Main Floor, Paint Booth, Heat Treating Plant, Tool Maintenance Area Moderately Quiet Sound Average Commercial High Sound 50.1 Plus 78.1 to 85+ 84.1 to 90+ (2) Manufacturing Area, Heavy Machine Foundry, Assembly Line, Machine Shops, Punch Press Shop, Light Machine Area, Boiler Room, Emergency Generator Room, Pump House, Power Plant, Transformer, Steel Mill, Engine Test Room, Compressor Room, Steel Stamping Extremely Heavy Industrial Notes: (1) dba range of A-weighted sound levels, in decibels. (2) Sound levels this high are subject to OSHA Standards for safety, as well as state and local ordinances. Sound attenuation provisions should be considered. Source: ASHRAE, AMCA Publications. 8 PENNBARRY

Engineering Data Fan Laws The following section includes engineering and technical data, guidelines and system explanations related to air moving and control devices. Fan laws and system descriptions are consistent with industry standards, definitions and accepted practices. This information is provided to assist system designers in sizing, selecting and defining their air moving and control systems as well as explaining variables inherent in system design. There are nine fan laws, three are of prime importance to the understanding of ventilation systems. These, together with an appreciation of fan types, should help avoid most problems with poor airflow performance. These three laws assume the same fan operating with air at a constant density. 1. Airflow and fan speed are directly proportional. 2 = 1 2 1 1 is the original flow rate in cu. ft. per minute. 2 is the desired flow rate in cu. ft. per minute. 1 is the original rotational speed of the fan. 2 is the desired rotational speed of the fan. 2. Pressure varies as the square of the fan speed or airflow. P P 2 1 2 = 1 P 1 is the original static pressure. P 2 is the desired static pressure. 3. Power varies as the cube of fan speed. 2 1 2 2 = 1 3 P2 2 = P1 1 1 is the original brake horsepower 2 is the desired brake horsepower 2 Interaction of Fan Curves & System Curves A ventilation system using a Zephyr Cabinet may consist of a fan with duct connected to the inlet side. Control dampers, grilles, registers and duct fittings may also be part of the system. The fan is the component in the system which provides energy to the airstream to overcome the resistance to flow off the other components. The determination of the pressure loss or resistance to flow, for the individual components can be obtained from the component manufacturers. The determination of pressure losses for ductwork and branch ductwork design is well documented in standard handbooks, such as the ASHRAE Handbook of Fundamentals. The fan curve shown in Figure 1 is a typical fan performance curve, developed through the actual testing of a fan in an air tunnel. The fan is run at constant speed and constant air density. When the fan is installed in the field, then it becomes part of the system. System curves are developed by using field tested data and applying fan laws. The point of intersection of the system curve and the fan performance curve determines the actual flow volume. If the system resistance has been accurately determined, and the fan properly s elected, the performance curves will intersect at the system design point (point A). Figure 1: Static Pressure - Inches W.G. 1.500 1.375 1.125 1.000 0.875 0.750 0.625 0.500 0.375 0.125 0 Interaction of System Curves and Fan Curves UNDER ESTIMATED S.P. RESULTS IN HIGH STATIC LOW C.F.M. FAN CURVE DUCT SYSTEM A SYSTEM DESIGN POINT OVER ESTIMATED S.P. RESULTS IN LOW STATIC HIGH C.F.M. 0 200 400 600 800 1000 1200 1400 1600 1800 2000 Reprinted from AMCA publication 201, Fans and Systems, with the express written permission from the Air Movement and Control Association International, Inc., 30 West University Drive, Arlington Heights, IL 60004-1893. PENNBARRY 9

Engineering Notes If the system resistance has been underestimated, then fan curves and system curves will not intersect at the system design point. They will intersect at lower (point B). If the system resistance has been overestimated, then the fan curve system curve will intersect at a higher than the system design point (point C) (see Figure 1). Effect of Change in Density, Altitude and Temperature Correction Factors The resistance of a duct system is dependent upon the density of the gas flowing through the system. A gas density of 0.075 lb/ft 3 is standard in the fan industry. Pressure and horsepower vary directly as the ratio of the gas density at the fan inlet to standard density. This density ratio must always be considered when selecting fans. To select a fan, pressure should be corrected to standard air density, 0.075 lb/ft 3, 70ºF. at sea level. Static pressure at operating condition x correction factor=static pressure at standard. Refer to Table 1. Table 1 Correction Factors Unity Basis = Standard Air Density of 0.075 lb/ft 3 At sea level (29.92 in. Hg barometric pressure) this is equivalent to dry air at 70 F. ALTITUDE (FEET) WITH BAROMETRIC PRESSURE (Inches Hg) TEMP 0 500 1000 1500 2000 2500 3000 3500' 4000 4500 5000 F 29.92 29.38 28.86 28.33 27.82 27.31 26.82 26.32 25.84 25.36 24.9-40 0.79 0.81 0.82 0.84 0.85 0.87 0.88 0.9 0.92 0.93 0.95 0 0.87 0.88 0.9 0.92 0.93 0.95 0.97 0.99 1 1.02 1.04 40 0.94 0.96 0.98 1 1.01 1.03 1.05 1.07 1.09 1.11 1.13 70 1 1.02 1.04 1.06 1.08 1.1 1.12 1.14 1.16 1.18 1.2 80 1.02 1.04 1.06 1.08 1.1 1.12 1.14 1.16 1.18 1.2 1.22 100 1.06 1.08 1.1 1.12 1.14 1.16 1.18 1.2 1.22 1.25 1.27 Horsepower at standard correction factor = horsepower at operating condition. Motors should be sized for highest density conditions at which it is expected to operate. Inlet System Effect For roof mounted exhaust fans, the most common installation problem is ductwork connection to the inlet side of the fan. Here are several design criteria for connecting ductwork to the fan. Keep a straight duct run twice the diameter of the inlet size immediately before the inlet of the fan. This will give the air a chance to straighten out before entering the fan. Fan inlet swirl and non-uniform inlet flow can often be corrected by inlet straightening vanes or guide vanes. Restricted fan inlets located too close to walls, obstructions or restrictions caused by a plenum or cabinet, will decrease the useable performance of a fan. Cabinet clearance effect or plenum effect must be considered a component part of the entire system; the pressure losses through the cabinet or plenum effect is considered as a System Effect when determining system characteristics. The backdraft damper is part of external static pressure, and should be accounted for when estimating system static pressure. Use a motorized backdraft damper when the fan has a variable speed controller. System Effect A System Effect Factor is a pressure loss which recognizes the effect of fan inlet restrictions, fan outlet restrictions or other conditions influencing fan performance when installed in the system. Figure 2 illustrates deficient fan/system performance resulting from one or more undesirable flow conditions. It is assumed that the system pressure losses, shown in system curve A, have been accurately determined, and a suitable fan selected for operation at Point 1. However, no allowance has been made for the effect of the system connections on the fan s performance. To compensate for this System Effect, it will be necessary to add a System Effect Factor (SEF) to the calculated system pressure losses to determine the actual system curve. The SEF for any given configuration is velocity dependent and will, therefore, vary across the range of flow volumes for the fan. In Figure 2, the point of intersection between the fan performance curve and the actual system curve B is Point 4. The actual flow volume will, therefore, be deficient by the difference from 1-4. To achieve design flow volume, an SEF equal to the pressure difference between Point 1 and 2 should have been added to the calculated system pressure losses and the fan selected to operate at Point 2. Note that because the System Effect is velocity related, the difference represented between Points 1 and 2 is greater than the difference between Points 3 and 4. The SEF includes only the effect of the system configuration on the fan s performance. Figure 2 DESIGN PRESSURE SYSTEM EFFECT AT ACTUAL FLOW VOLUME DEFICIENT PERFORMANCE DESIGN VOLUME Deficient Fan/Duct System Performance System Effect Ignored CURVE B ACTUAL DUCT SYSTEM WITH SYSTEM EFFECT CURVE A CALCULATED DUCT SYSTEM WITH NO ALLOWANCE FOR SYSTEM EFFECT SYSTEM EFFECT LOSS AT DESIGN VOLUME FAN CATALOG PRESSURE- VOLUME CURVE Reprinted from AMCA publication 201, Fans and Systems, with the express written permission from the Air Movement and Control Association International, Inc., 30 West University Drive, Arlington Heights, IL 60004-1893. 10 PENNBARRY

Engineering Notes Inlet Duct Elbows Non-uniform flow into a fan inlet is the most common cause of deficient fan performance. An elbow located at, or in close proximity to the fan inlet will not allow the air to enter the impeller uniformly. The result is less than cataloged air performance. (See Figure 3). Figure 3 NON-UNIFORM FLOW INDUCED INTO FAN INLET BY A RECTANGULAR INLET DUCT Inlet Vortex (Spin or Swirl) Another major cause of reduced performance is an inlet duct condition that produces a vortex or spin in the airstream entering a fan inlet. The ideal inlet condition is one which allows the air to enter axially and uniformly without spin in either direction. A spin in the same direction as the impeller rotation (pre-rotation) reduces the pressure volume curve by an amount dependent upon the intensity of the vortex. The effect is similar to the change in the pressure volume curve achieved by inlet vanes installed in a fan inlet; the vanes induce a controlled spin in the direction of impeller rotation reducing the volume flow rate. A counter-rotating vortex at the inlet may result in a slight increase in the pressure-volume curve but the horsepower will increase substantially. Inlet Turning Vanes LENGTH OF DUCT NON-UNIFORM FLOW INTO A FAN INLET INDUCED BY A 9O 3 - PIECE SECTION ELBOW. NO TURNING VANES Reprinted from AMCA publication 201, Fans and Systems, with the express written permission from the Air Movement and Control Association International, Inc., 30 West University Drive, Arlington Heights, IL 60004-1893. Where space limitations prevent the use of optimum fan inlet connections, more uniform flow can be achieved by the use Figure 4 of turning vanes in the inlet elbow (see Figure 4). Numerous variations of turning vanes are available from a single curved sheet metal vane to multibladed airfoil vanes. The pressure drop through TURNING these devices must be VANES added to the system pressure losses. Reprinted from AMCA publication 201, Fans and Systems, with the express written permission from the Air Movement and Control Association International, Inc., 30 West University Drive, Arlington Heights, IL 60004-1893. Spark Resistant Construction AMCA standards offer the following definitions and notes concerning spark resistant construction: C - The fan shall be so constructed that a shift in the impeller or shaft will not permit two ferrous parts of the fan to rub or strike. B - The fan shall have a non-ferrous impeller and non-ferrous ring about the opening through which the shaft passes. Ferrous hubs, shafts and hardware are allowed, provided construction is such that a shift in impeller or shaft will not permit two ferrous parts of the fan to rub or strike. Steps must also be taken to insure that the impeller, bearings, and shaft are adequately attached and/or restrained to prevent a lateral or axial shift in these components. Zephyr Cabinet units are available with AMCA B construction as an option. Notes: 1. No bearings, drive components or electrical components shall be placed in the air or gas stream unless they are constructed or enclosed in such a manner that failure of the component cannot ignite the surrounding gas stream. 2. The user shall electrically ground on all fan parts. 3. For this standard, non-ferrous shall be any material with less than 5% iron or any other material with demonstrated ability to be spark resistant. 4. The use of aluminum or aluminum alloys in the presence of steel which has been allowed to rust requires special consideration. Research by the U.S. Bureau of Mines and others has shown that aluminum impellers rubbing on rusty steel may cause high-intensity sparking. The use of the above standard in no way implies a guarantee of safety for any level of spark resistance. Spark resistant construction does not protect against ignition of explosive gases caused by catastrophic failure or from any airstream material that may be present in a system. Metric Equivalents For your convenience, the table below provides conversion factors from English to Metric. CATEGORY AMCA STANDARD / x CONVERSION ENGLISH UNIT FACTOR = METRIC (SI) UNIT VOLUME FLOW 0.00047195 cu. meter per sec. (m 3 /s) PRESSURE Inches (wg) 248.36 pascal (Pa or N/m 2 ) POWER H.P. 745.7 watt (W or J/s) TEMPERATURE Fahrenheit ( F) ( F + 459.67)/1.8 kelvin HEAT Btu 1.055 kilojoules (kj) TIP SPEED ft/m 0.00508 meter per second (m/s) SPEED 0.016 rev. per second (rps) VELOCITY Ft/M 0.00508 meter per second (m/s) DIMENSIONS Inches 25.4 millimeter (mm) Feet 0.3048 meter (m) Square Feet 0.0929 square meter (m 2 ) Cubic Feet 0.0283 cubic meter (m 3 ) PENNBARRY 11

Engineering Notes ZC and ZCC Belt Drive Losses The AMCA Review Committee has developed the chart shown here for the purpose of estimating belt drive losses. To calculate total (including drive losses): Find the of your operating point on the X-Axis of the chart. Follow the vertical line to the lines indicating the range of drive losses. Look at the Y-Axis on the left and find the drive loss percentage. Calculate the total by adding the drive losses to the operating point. For s below 1/3, use 30%. Typical Applications Zephyr ZC and ZCC Cabinet fan units are versatile in application. They may be used in ventilation, recirculation, and air conditioning systems as typified by the illustrations below. Dampers, inlet/outlet air diffusers/grilles, cooking appliances, air conditioning coils and ducting shown are typically furnished by others but in part may be available from PennBarry. Caution: For totally enclosed, explosion proof, multi-speed and all 1.0 Service Factor motors, fan plus drive losses should not exceed motor rated HP. EXHAUST AIR Range of drive loss for standard belts. Higher fan speeds tend to have higher losses than lower fan speeds at the same horsepower. SUPPLY AIR (COOLING/HEATING) RETURN AIR / RECIRCULATION Note: FanSizer software incorporates a drive loss allowance when selecting a required nominal horsepower. Reprinted from AMCA publication 203, with the express written permission from the Air Movement and Control Association, Inc., 30 West University Drive, Arlington Heights, IL 60004-1983 SUPPLY AIR (VENTILATION) CEILING PLENUM AIR / RECIRCULATION SUPPLY AIR (VENTILATION) 12 PENNBARRY

Sample Specifications ZC Units Belt drive Cabinet Inline Duct fan shall be Zephyr ZC, manufactured by PennBarry, Richardson, TX 75081. Fan housing shall be galvanized steel, shall enclose the motor/fan assembly, & include removable side panels to allow access to the motor/fan assembly. Fans shall have a forward curved centrifugal wheel. Fan motors shall be continuous duty, ball bearing design, permanently lubricated, positively cooled, & furnished at the specified voltage, phase, & enclosure. Each fan shall bear the AMCA Licensed Ratings Seal for Air Performance. ZCC Units Belt drive Dual Cabinet Inline Duct fan shall be Zephyr ZCC, manufactured by PennBarry, Richardson, TX 75081. Fan housing shall be galvanized steel, shall enclose two motor/fan assemblies, & include removable side panels to allow access to the motor/fan assemblies. Fans shall have a forward curved centrifugal wheels. Fan motors shall be continuous duty, ball bearing design, permanently lubricated, positively cooled, & furnished at the specified voltage, phase, & enclosure. Each fan shall bear the AMCA Licensed Ratings Seal for Air Performance. PENNBARRY 13

One Year Limited Warranty What Products Are Covered PennBarry Fans and Ventilators (each, a "PennBarry Product") One Year Limited Warranty For PennBarry Products PennBarry warrants to the original commercial purchaser that the PennBarry Products will be free from defects in material and workmanship for a period of one (1) year from the date of shipment. Exclusive Remedy PennBarry will, at its option, repair or replace (without removal or installation) the affected components of any defective PennBarry Product; repair or replace (without removal or installation) the entire defective PennBarry Product; or refund the invoice price of the PennBarry Product. In all cases, a reasonable time period must be allowed for warranty repairs to be completed. What You Must Do In order to make a claim under these warranties: 1. You must be the original commercial purchaser of the PennBarry Product. 2. You must promptly notify us, within the warranty period, of any defect and provide us with any substantiation that we may reasonably request. 3. The PennBarry Product must have been installed and maintained in accordance with good industry practice and any specific PennBarry recommendations. Exclusions These warranties do not cover defects caused by: 1. Improper design or operation of the system into which the PennBarry Product is incorporated. 2. Improper installation. 3. Accident, abuse or misuse. 4. Unreasonable use (including any use for non-commercial purposes, failure to provide reasonable and necessary maintenance as specified by PennBarry, misapplication and operation in excess of stated performance characteristics). 5. Components not manufactured by PennBarry. Limitations 1. In all cases, PennBarry reserves the right to fully satisfy its obligations under the Limited Warranties by refunding the invoice price of the defective PennBarry Product (or, if the PennBarry Product has been discontinued, of the most nearly comparable current product). 2. PennBarry reserves the right to furnish a substitute or replacement component or product in the event a PennBarry Product or any component of the product is discontinued or otherwise unavailable. 3. PennBarry's only obligation with respect to components not manufactured by PennBarry shall be to pass through the warranty made by the manufacturer of the defective component. General The foregoing warranties are exclusive and in lieu of all other warranties except that of title, whether written, oral or implied, in fact or in law (including any warranty of merchantability or fitness for a particular purpose). PennBarry hereby disclaims any liability for special, punitive, indirect, incidental or consequential damages, including without limitation lost profits or revenues, loss of use of equipment, cost of capital, cost of substitute products, facilities or services, downtime, shutdown or slowdown costs. The remedies of the original commercial purchaser set forth herein are exclusive and the liability of PennBarry with respect to the PennBarry Products, whether in contract, tort, warranty, strict liability or other legal theory shall not exceed the invoice price charged by PennBarry to its customer for the affected PennBarry Product at the time the claim is made. Inquiries regarding these warranties should be sent to: PennBarry, 1401 North Plano Road, Richardson, TX 75081 14 PENNBARRY

OTHER PENNBARRY PRODUCTS CENTRIFUGAL PRODUCTS Domex Centrifugal Roof Exhausters Fumex Fatrap Kitchen Hood Centrifugal Roof Exhausters Zephyr Ceiling and Inline Fans Dynamo Centrifugal Blowers Centrex Inliner Centrifugal Inline Fans LC Dynafan Low Contour Centrifugal Roof Exhausters ESI Efficient Silent Inline Fan Fume Exhaust Curb Mounted Centrifugal Fans AXIAL / GRAVITY PRODUCTS Breezeway Propeller Wall Fans HI-EX Power Roof Ventilator Tubeaxial Inline Fans Vaneaxial Inline Fans Powered Airette Axial Roof Ventilators Airette Gravity Intake/Relief Hood Domex Axial Axial Roof Ventilators Axcentrix Bifurcator Fan For more information contact your local PennBarry Sales Manufacturer Representative or visit us at www.pennbarry.com 2005 PennBarry All Rights Reserved. February 2005