(EN) RevC AS610-AS630 Outdoor Siren Installation Sheet.pdf. Remark: Rev. Date: Modif. no.

Similar documents
TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

IFS Fiber Module Installation & Operation Instructions

Advisor Advanced User Guide

KFP-CF Series Operation Manual

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

KM300 Carbon Monoxide Detection System Installation Manual

IFS SFP Tranceivers User Manual

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

1X-F Series Installation Manual

SIGA-CC1 Single Input Signal Module Installation Sheet

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation

ZP2 Series Operation Manual

FEC403EN Installation Manual

NX-181xx NetworX Voice keypad with touch buttons User Manual

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

TruVision Bullet IR Camera Pocket Guide

ATS125x/1260 Four- Door/Four-Lift DGP Programming Guide

Installation Manual. Wiegand Interface Unit Four-State (WIU-4) North America T F Asia T F

TruVision Bullet IR Camera Pocket Guide

DI601AM Outdoor PIR/AM Detector Installation Sheet

Premier External TD. Installation Manual INS352-3

900 Series Protocol Guide for 2X Series Control Panels

Temporary wireless battery operated fire system from Channel Safety Systems

TX7110. Intelligent Heat Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. External Sounder & Strobe Unit

Installation Manual. Premier IXP-W INS538

R Series Remote Annunciators and Expander Installation and Operation Guide

Transition 500-PIV Series Multi-Technology Readers Installation Manual

Installation Manual Premier Elite IXP-W

FTP-1000 Touchpad/Display Installation Manual

IR Speed Dome. Quick Guide UD.6L0201B1357A01

R-Series Remote Annunciators and Expanders Installation and Operation Guide

KFP-AF Series Fire Alarm Control Panel Installation Manual

NetworX NX-548E Receiver Installation Instructions

Installation Manual. Odyssey X Series INS627-2

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

VS-AXESS-4DLX Installation Manual

GE Security. ATS1250/ door DGP / 4-lift DGP. Installation guide

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

Field Configurable Horns and Strobes

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

Installation Manual. Wiegand Interface Unit Two-State (WIU-2) North America T F Asia T F

FW-SIREN2EXT -8/9F FW-SIREN2CP -8/9F

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

STEP-HEAR Activator (SH-220)

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

DS-K2600 Series. Access Controller. Quick Start Guide UD01216B-A

14300 MAINS SEPARATOR ALARM MANUAL

Field Configurable Horns and Strobes

UC-331-UCX Dual Path Communication Module. Quick Start Guide

Installation and Operation Manual

Certificate of constancy of performance,

AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

ELECTRONIC SOUNDER STROBE Model : AVD-C407

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

INSTRUCTION MANUAL FOR: WIRELESS SECURITY STARTER KIT MODEL NO: SWSKIT

C e r t i f i c a t e

Apollo Intelligent Auto Aligning Beam Detector. User Guide

TX24-10A. Intelligent PSU Installation and Operation Manual. TANDA UK Technology Copyright 2016, All right reserved.

INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX

Fire Signalling. Signalling Solutions

Installation Instructions

FiRe mobile-2 Operation Manual

TX7100. Intelligent Addressable Optical Smoke Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13

Diamond Cut 2 Slice Toaster Cool Touch Plastic

SMART Electronic control for towel radiators

Universal Tank Alarm Type Installation, Operation & Maintenance

Alarm Tone Generator Model AG17

Certificate of constancy of performance,

Fire Signalling. Signalling Solutions

Xenex Conventional Fire Detection & Alarm System

Advisor Advanced Mobile Application User Manual

Undercounter Refrigerator Operation Manual i.series and Horizon Series

Print Specification. Publication. Instructions. Specific requirements. General requirements

Fire Signalling. Signalling Solutions

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

SDR-WEXT Wired Siren Installation Guide

WIRELESS MEASUREMENT SYSTEM OF GAS BOTTLES FILLING LEVEL WITH GAS LEAK DETECTION GMS 300. User Manual

Professional HEPA Air Cleaner

62 MAX/62 MAX + Infrared Thermometer

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Concord 5 TouchScreen Installation Sheet

Imperial Electric Fires

HYTEK ATEX APPROVED BUND ALARM

Remote Booster Power Supply Technical Reference Manual

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Conventional Fire Detection

FIRE AND SAFETY. Manual Call Points p15-1 Magnetic Door Holders p15-3 Detection Cables p15-4 Portable Signals p15-7 Solar Powered Signals p

WIRELESS DOOR/WINDOW CONTACT ACCESSORY (WHA3)

Transcription:

44989999-3 (EN) RevC AS60-AS630 Outdoor Siren Installation Sheet.pdf. Form: A5 double sided printing 2. Fold to fit in box Remark: Rev. Date: Modif. no. Scale: White paper: 75 gr/m, progresso; overprint black. A 7-04- 0 Proj.Am AS60-AS630 Installation Sheet B 8-03-'03 02 C 7-04-'03 235 44989999-3 2 C 5-2- 09 3 A 5-2- 0 Name: Mikhail Sleptsov Date: 4-2-202 Supers: C 4-2- 2 Size: A4 Property Sh. : 0-0 UTC Fire & Security of:

AS60/AS630 Outdoor Siren Installation Sheet EN AS60 AS630 2 TOP 202 UTC Fire & Security Americas Corporation, Inc. / 4 P/N 44989999-3 (EN) REV C ISS 4DEC2 All rights reserved.

3 4 Pb maintenance free aucun entretien onderhoudsvrij sin mantenimiento wartungsfrei nessuna manutenzione BS 2 N 2 V - 7.2 Ah Max. Charge Temp. 5 2 2 / 4 P/N 44989999-3 (EN) REV C ISS 4DEC2

6 BLACK - SPEAKER RED CUT-OFF TIMER - J J2 J3 HOLD OFF PROGRAMMING J7 J6 J5 J4 - - BEACON RED BLACK - 2 3 3.0-4 5 6 Siren 2 4.2 VDC 0 V Tamper Tamper K UK / IRL only K 39 53 52 57 33 34 CD95 52 54 58 57 N/A 34 CD95 UK / IRL 66 70 72 73 33 34 CD9502S3 39 2 3 8 30 3 CD72 / CD44 3 26 25 28 4 5 CS24 / CD34 7 9 8 2 20 2 - - N/A CS50 STRB STRB EXT EXT WIRED TO () (-) (S-) K (S) "A" ZONE ATS SERIES J7 Siren J5 7 EN: Installation Sheet S3 S4 S5 S C S2 C T C LC-OUTPUTS HC-OUTPUTS SIR TMP 3.0 to Siren 4.2 VDC 0 V Tamper Tamper 2 3 4 5 6 Description AS6x series is a high quality installer-friendly self activating outdoor siren with a sound output of 20 db at metre and a single beacon, which meet today's security and environmental requirements. The housing is made of tough UV proof and impact resistant 3.5 mm polycarbonate and has a foamresistant steel inner cover for the ultimate in protection. AS630 is a high quality installer-friendly self activating outdoor siren with a sound output of 20 db at metre and a single amber beacon, which meet today's security and environmental requirements. The cover is made of highly polished stainless steel and has a foam-resistant steel inner cover for the ultimate in protection. P/N 44989999-3 (EN) REV C ISS 4DEC2 3 / 4

Wiring procedure First, wire the control panel (power down) to the siren as shown above, before connecting the battery. When the battery is connected for the first time, the siren will give a short beep. The siren cannot be activated until all inputs (input power and hold-off voltages) are correct. The siren will be activated if the input power is removed or drops significantly or if the siren hold-off voltage is removed. Siren cut-off time is controlled by J and J2. For use without a battery, cut jumper J3. Note: J3 is not available in the AS69 but the AS69 can be used with or without battery. Figure 7 shows an example connection between the siren and an Advisor Advanced control panel. WARNING: The beacon uses high voltage. To avoid personal injury or death from electrocution, do not touch bare wires and beacon electronics before the energy discharges. Table : Timer programming J J2 Time (min) J J2 Time (min) Default 3 0 5 20 Table 2: Hold-off programming Siren J4 J5 Terminal 2 J6 J7 Terminal Default Floating Default Floating 2 V or floating 2 V or floating 0 V or floating 0 V or floating [] To be connected to an external current limited power supply (advised 5 A) [2] Sound output for AS69: 85 db at 3 m When on the AS69, the siren hold off voltage is removed the siren output is activated in a one minute on one minute off sequence. Regulatory information Manufacturer Certification UTC Fire & Security Americas Corporation, Inc. 275 Red Fox Rd., Arden Hills, MN 552-6943, USA Authorized EU manufacturing representative: UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, Netherlands EN The AS60, AS69 and AS630 are EN 503-4 Security grade 3, Environmental class III. All mounting screws have to be fitted as that they form a part of the tamper device. Tested and certified by the Norwegian testing and certification body DNV. The AS60, AS69 and AS630 are certified for EN 503-4 only if used without a battery. 2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info. Contact information www.utcfireandsecurity.com or www.interlogix.com. For customer support, see www.utcfssecurityproducts.eu Specifications Supply [] 3.0 to 4.2 V Standby current 25 ma (closed line) Operating current 0.6 A Sound output [2] 8 db at m; 09 db at 3 m Frequency.8 to 2.8 khz Cut off timer Preset at 3 min, adjustable 5, 0, 20 min Working temperature 25 to 70 C (without battery) EN 503: 25 to 55 C (without battery) 0 to 40 C (with battery) Relative humidity EN 503: 93% max. Weight 2.5 kg Dimensions 305 x 220 x 87 mm Recommended battery BS27 or BS2 Supply 3.8 V Operating current 0 ma Light output 00.000 peak lumens Life time.000.000 flashes Flash rate Hz Spike suppression Standard fitted network 4 / 4 P/N 44989999-3 (EN) REV C ISS 4DEC2