LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

Similar documents
LS Condensate Removal Pump Installation, Operation and Service Instructions

INSTRUCTION MANUAL A REVISION A. Series e 3-4/e 3-6 Instant Hot Water Recirculating Systems

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Dehumidifier. Instruction Manual. Model DH-320/A

Threaded. Flanged. Model PSH. Primary Secondary Header A-451

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Hoffman Specialty Watchman Series WC & WCS Condensate Units Replacement Parts PART LISTS DN0436C

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

GDDEM10 DEHUMIDIFIER

Removing shipping locks

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

EN Z Subject to change due to technical improvements! Operating instructions

WASHING MACHINE SERVICE MANUAL CAUTION READ THIS MANUAL CAREFULLY TO DIAGNOSE PROBLEMS CORRECTLY BEFORE SERVICING THE UNIT.

INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE (GB)

Unpacking and removing shipping bolts. Connecting the drain line Leveling the washer Connecting to the power supply

TECHNICAL INFORMATION Touchtronic Clothes Dryers

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

Hand Dryer Installation & User Manual

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

Operating instructions

Installation Instructions for. OmniFount

Moisture inside the drum is due to final testing.

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Glass and Dishwashers AMX / AUX Series

SAVE. Features. Excellent drying laundry function. Powerful dehumidifying capability. Quiet operation

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

JT-SB116JH-G-NA JT-SB116JH-W-NA

INSTALLATION GUIDE NZ AU C

INSTALLATION INSTRUCTIONS

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

DEHUMIDIFIER MODELS: SD-30E / SD-40E / SD-65E INSTRUCTION MANUAL

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

OPERATION & MAINTENANCE INSTRUCTIONS

Operating instructions

MODEL: DC10RCDH / DC12RCDH

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

PORTABLE DEHUMIDIFIER

PORTABLE AIR CONDITIONER

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

INSTALLATION GUIDE NZ AU

Tornado Operations & Maintenance Manual

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

SUBMERSIBLE WATER PUMPS

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

Greenleaf 100 Toilet Macerator Waste Pump Instruction Manual

Viking Installation Guide

AIR CONDITIONING UNIT

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Virtu 60 and 80 series. Coffee machine

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

OWNERS GUIDE TO INSTALLATION AND OPERATION

Glass and Dishwashers AMX / AUX Series

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

ICE MAKER. Model: IM-101 INSTRUCTION MANUAL

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Coffee Machine Zia series

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

QUICK CONNECT INSTALLATION MANUAL DUCTLESS MINI-SPLIT SYSTEM FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36

Operation Manual. Trash Water Pump ARTICLE Image similar

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

Automatic Water System Pump SERIES

Two Tier Illumifalls Patio Pond

MODEL 7000 SUCTION UNIT

A few simple steps to ensure perfect water, every time.

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

SERVICE MANUAL WASHING MACHINE MODEL: WM3431H*/WM3434H* WD-14312RD/WD-14316RD CAUTION

Instruction Manual Item No.: V~, 60Hz

Inverter Swimming Pool Heat Pump

INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP

Installation, Operation, and Maintenance Manual. NRF -25,36,45/NBF -25,36, and 45 Circulator

Coffee Machine Siro Touch 600 series

SERVICE MANUAL WASHING MACHINE

Dishwasher Installation Manual

Fundamental safety warnings

SUBMERSIBLE DIRTY WATER PUMP

Models: RP-10, RP-15, RP-20. User Manual

GARDENA. F 3000 Art F 6000 Art F 9000 Art F Art. 7929

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

Virtu 40 series. Coffee machine

Model S-530 Coin Sorter / Value Counter Operating Manual

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

ISTRUZIONI PER L USO. Climatizzatore CT300 - CT300H

hp Dust Collector With Vacuum Attachment

Transcription:

LS Condensate Removal Pump INSTRUCTION MANUAL 6-71-075-115 REVISION A

CAUTION: Combustible liquids may not be pumped! The condensate pump may not be run dry, as this can destroy the bearings in a very short period. Applications The LS is designed for condensate from: Gas or oil condensing boiler (maximum heating capacity 682,000 BTU/h) with ph of 2.7 or higher Air conditioning systems, cooling, and refrigeration systems. Air dehumidifiers and evaporators Specifications Supply voltage 100-240 V Frequency 50 / 60 Hz P1 power supply capacity 20 Watt Current consumption 0.2 0.1 A Degree of protection IP 44 / Class F Max. delivery head 45 kpa Max. pump capacity 450 l/h Noise level (L w ) 46 db(a) Acid resistance ph 2 or higher Max. media temperature + 140 F (60 C) Min. ambient temperature Not freezing 50 F (10 C) Floating contact Break contact, switching capacity 250 VA Tank volume 0.7 l (usable volume 0.5 l) Packaging dimensions 8.5 x 8.5 x 7.1 (215x215x180 mm) Packaging weight 3.52 lbs (1.6 kg) Subject to technical changes due to product modifications Fig.2 Dimensional Drawings Fig.3 4.65 (118) 5.83 (148) 3.54 (90) 6.61 (168)

Included Items Your LS Condensate Pump should include the following items. See Fig.4 below. (a) (b) (c) (d) a. LS Condensate Pump unit b. Mounting bracket (designed for rear wall or left side wall mounting) c. Pressure hose connection kit d. Pressure hose (19ft.) Optional items that may be needed for pump installation: Hose clamps Safety Requirements Prior to starting the installation process, please observe and understand the following safety requirements. Failure to understand these instructions could result in personal injury, death, and/or property damage. Mechanical Safety WARNING: - Excessive System Pressure Hazard - The maximum working pressure of the pump is listed on the nameplate - Do Not Exceed This Pressure. Failure to follow these instructions could result in serious personal injury, death and/or property damage. WARNING: - Excessive Pressure Hazard Volumetric Expansion - The heating of water and other fluids causes volumetric expansion. The associated forces may cause failure of system components and the release of high temperature fluids. This can be prevented by installing property sized and located compression tanks and pressure relief valves. Failure to follow these instructions could result in serious personal injury, death and/or property damage. Thermal Safety WARNING: - Extreme Temperature Hazard - If the pump, motor or piping are operating at extremely high or low temperature, guarding or insulation is required. Failure to follow these instructions could result in serious personal injury, death and/or property damage. Electrical Safety WARNING: - Electrical Shock Hazard - Electrical connections are to be made by a qualified electrician in accordance with all applicable codes, ordinances and good practices. Failure to follow these instructions could result in serious personal injury, death and/or property damage. WARNING: - Electrical Grounding Hazard - Adequate electrical grounding is required for the safe operation of B&G Pumps. Connect the ground wire to the ground terminal in the wiring compartment. Failure to follow these instructions could result in serious personal injury, death and/or property damage. WARNING: - Risk of Electric Shock - Do not install this pump in swimming pool or marine areas. Failure to follow these instructions could result in serious personal injury, death and/or property damage. Installation The LS Condensate Pump must be installed in dry rooms (frost proof and where the air temperature does not exceed 140 F (60 C) using the installation bracket provided. It is mounted to the wall below the condensate supply outlet. Ensure that the pump is mounted horizontally. If floor-mounted, ensure that it is in a stable position We recommend that you also secure it to the nearest wall. WARNING: The unit may not be installed in areas where there is a danger of explosion! After a suitable location for installation has been determined. Follow these steps and pre-cautions continued on the next page:

1. Condensate supply hose must be routed with a downward slope to the LS Condensate Pump. (See Fig.5) 2. Ensure condensate supply hose is inserted deep enough into the tank inlet so that it cannot slip out unintentionally. A second inlet opening is available for additional hose connections. 3. For installation of the condensate drainage hose ensure hose is inserted as far as possible onto the non-return valve. Tip: We recommend that you also secure the hoses using hose clamps. 4. After securing hose on non-return valve, lock non- return valve by rotating valve one quarter turn clockwise. Electrical Connection The LS has a 6.5 ft (2m) long mains cable with a shock-proof plug. If the cable is not long enough, we recommend that you use an extension lead or connect a distribution box. The mains cable is permanently connected to the pump and cannot be removed and replaced with a longer mains cable. The electrical connection used must comply with the applicable standards. In particular, it must be properly earthed and fused. WARNING: All electrical work done may only be performed by qualified electrical professionals. Alarm connection The LS Condensate Pump is equipped with an alarm connection (switching with a 15 sec delay). This allows the condensing or air conditioning system to be switched off to prevent more condensate being fed and the tank overflowing. If the alarm connection is to be used, the 6.5 ft (2m) alarm connection cable must be connected as shown in the illustration. If the cable is not long enough, we recommend that you connect a distribution box. The alarm cable is permanently connected to the pump and cannot be removed. If the alarm connection is not used, the alarm cable can be cut off directly at the pump. In order to prevent moisture penetrating into the pump electronics, replace the original rubber cap with the hole with the closed rubber cap provided. Functional Testing After installing the condensate pump, we recommend that you test it to ensure that it functions correctly. To test the function, pour water (approx. 0.4 l) into the tank via the secondary inlet opening if possible, until the activation level is reached and the pump starts. If air in the pump causes the integrated dry-run protection to actuate (pump deactivates, green and red operating lamp flash), add a further 0.2 l of water and wait for one minute. The pump restarts automatically after one minute. The LS condensate pump is now functional. Routine Maintenance and Disassembly of LS Condensate Unit Fig.5 Fig.6 4 L N PE max. 4m WARNING: The LS Condensate Pump must be disconnected from the mains power supply before maintenance or disassembly! The LS pump does not require special maintenance. However, we recommend that you remove encrustation and rinse with clear water regularly in accordance with the occurrence of soiling. When you press in the clip, the LS can be removed by pulling it upwards away from the mounting bracket (see exploded view illustration). Disassembly of the condensate pump: Remove the pressure hose and non-return valve from the pump housing by turning them one quarter turn counter-clockwise. Pull the condensate supply hose carefully out of the tank. WARNING: Condensate from condensing systems is aggressive. Avoid contact with residual condensate in the tank, in the condensate supply hose or in the pressure hose!

Operating Lights and Fault Overview Ready for operation = Steady green light Fault = Red light Pump running = Flashing green light The alarm output is opened when a fault occurs. WARNING: Work on electrical parts of the LS Condensate Pump may only be performed by qualified electrical professionals. Operating Green Lamp Red Cause Solution Off Off Mains plug not plugged in Insert plug Power failure Check mains and fuse Flashing Flashing Dry-run (Poss. air in tank) Pump restarts automatically after one minute On Flashing Pump blocked Visual inspection of the pump inlet in the tank and removal or rinsing of dirt or foreign bodies On On Level exceeds alarm level Pressure hose / non-return valve blocked (clean or remove kink if applicable) Off Flashing Pump blocked and alarm level Visual inspection of the pump inlet alarm exceeded level exceeded in the tank and removal or rinsing of dirt or foreign bodies; Warranty WARNING: The LS Condensate Pump must be disconnected from the mains power supply before maintenance or disassembly! Malfunctioning condensate pumps can be returned to the manufacturer s address. The manufacturer will refuse to accept packages with unpaid shipping or invoices for repair. The manufacturer guarantees the LS condensate pump for two years subject to correct installation and proper use of the device. Product Disposal This product and parts thereof must be disposed of in an environmentally friendly way. Corresponding local regulations must be observed. Product Breakdown 1. Condensate inlet (.95 24mm) 2. Additional inlet opening (6.95 24mm) 3. Magnet float 4. Mounting bracket (for rear wall or left side wall) 5. Clip 6. Main cable (6.5ft 2m) with shock-proof plug 7. Alarm connection cable (floating, 6.5ft 2m) 8. Non-contact electronic fill level detection with echo sensors 9. Connection for pressure hose (.55 x.08, 19ft) 10. Non-return valve with bayonet connection 11. Opening for non-return valve 12. Pressure nozzle 13. Tank (0.7l; usable volume 0.5l) 14. Permanent magnetic rotor/impeller 15. Pump sump 16. Operating LEDs 17. Stator of the high-efficiency spherical motor pump

Xylem Inc. 8200 N. Austin Avenue Morton Grove, Illinois 60053 Phone: (847) 966-3700 Fax: (847) 965-8379 www.xyleminc.com/brands/bellgossett Bell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries. 2012 Xylem, Inc. 6-71-075-115A July 2012