Welch. OEM, Industrial & Refrigeration Catalog. High Vacuum Rotary Vane Pumps. Dry (oil-free) Vacuum Pumps. Refrigeration Vacuum Pumps

Similar documents
Laboratory Vacuum Catalog

Vacuum Pump and Systems Catalog 2011/2012 WELCH-ILMVAC APPLIED VACUUM TECHNOLOGY

Oil-Sealed Rotary Vane Pumps

OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2581

Dry, oilfree Diaphragm Pumps

Dry, oilfree Diaphragm Pumps. Highlight NEW MPC 302 Z. 3 Diaphragm Pumps

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

2011/2012 Lab Catalog WELCH. Vacuum Pump and Systems Catalog WELCH-ILMVAC. APPLIED VACUUM TECHNOLOGY

WHAT ARE THE SPECIFICATIONS FOR THE VACUUM

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111

Thermo Scientific Air Cadet

APPLIED VACUUM TECHNOLOGY VACUUM PUMPS & SYSTEMS

WELCH WELCH-ILMVAC. Vacuum Pump and Systems Catalog PROVIDING VACUUM INNOVATION WORLDWIDE. APPLIED VACUUM TECHNOLOGY

High Output Vacuum/Pressure Pump

OWNER S MANUAL FOR DRY VACUUM PUMP MODELS: 2567B-01, 2567B-50, 2567C-02, 2567C-50

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS: / / / 2047

OWNER S MANUAL FOR WOB L PISTON VACUUM PUMP MODELS: 2561B B C C C C-25

OWNER S MANUAL FOR DRY VACUUM PUMP MODELS 2585B-01, 2585B-50, 2585B-55 & 2585Z-50

Freeze Dry Systems and Accessories

transport handle gas ballast valve robust design for long life easy to clean integrated oil level window quiet running, minimized vibrations

Freeze Dry Systems and Accessories

CentriVap. Centrifugal Vacuum Concentrators and Cold Traps

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS: 2014 / 2032 / 2042 / 2034 / 2044 / 2037 / 2047

OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2019

User Manual. Twin Piston Vacuum Pumps: Oil-less WVP Series: WVP12, WVP10, WVP5, WVP4, WVP3, and WVP2

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

CENTRIVAP CENTRIFUGAL CONCENTRATORS & COLD TRAPS

ISO-9001:2008 DESICCATORS CATALOG. Phone: Fax: Web:

Chemistry diaphragm pumps

1 and 2.5 Liter Freeze Dry Systems

Fuji Electronic VFC 084P-5T

APPLIED VACUUM TECHNOLOGY Vacuum Pumps and Systems

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

Blowers Vacuum Pumps Compressors INNOVATION DESIGN SOLUTIONS

Freeze Dry Systems and Accessories

CFH Series High Efficiency Filters

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

Tramp Oil. Removal Equipment Equipment designed for removing oil from water based fluids ERIEZ. ...Only from Eriez. Tramp Oil. Removal Equipment:

FreeZone 2.5 Liter Benchtop Freeze Dryers

Scientific vapor pumps

EM Oil Sealed Rotary Pumps

Vacuum Equipment. Manifolds. Traps. Pumps. Adapters. Easy to assemble Ace-Safe connector versions. O-Ring connections. Added safety and versatility

Vacuum Pumping process for Large Camera Dewars supplied by PixelVision of Oregon

Limited floor space. Removes 4 liters of water Available with Stoppering in 24 hours* Tray Dryer

General. Applications and Accessories for Oil Diffusion Pumps. leybold. Application. Accessories LEYBOJET 630 DIP DIP DIP DIP 30000

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

ROTARY EVAPORATORS EVAPORATION SOLUTIONS

R 5 Central Vacuum Systems

Thermo Scientific Modulyo Freeze Dryers

APPLIED VACUUM TECHNOLOGY. Vacuum Pumps and Systems

2016 Ideal Vacuum (505) V 1.1

KINNEY OIL MIST ELIMINATORS

Product Data. Features/Benefits. 19XB Positive Pressure Storage System

Custom Products Gallery

APPLIED VACUUM TECHNOLOGY. Vacuum Pumps and Systems

Vacuum Pumps America Inc. Dry Screw Vacuum Pump VSS Series

USER MANUAL UN-200V / UN-200VH

Vacuum Oil Purifier (VOP) (5 Pages. June 2017)

REFRIGERANT RECOVERY SYSTEMS

ROTATORY EVAPORATOR AND PUMPS

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

Roots TM Blowers, Compressors & Controls

Oil burners fuel unit with solenoid valve

Stokes Microvac Model 212J

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

Vacuum in the laboratory. products and solutions

Caresaver Universal Refrigerant Recovery Unit

OWNER S MANUAL FOR CHEMSTAR DRY MODELS: 2070, 2080

Using the DewTrak II Dew Point/ Humidity Transmitter

Order by phone Order on-line Order by fax Website

REFRIGERATED AIR DRYERS

Portable Purification zf04 Systems Models PVS 185, 600, 1200, 1800, 2700

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

vwr.com. L a b o r a t o r y P u m p s + S y s t e m s

Tel: Fax: Website:

SYNRAD Technical Bulletin # 0015d

Condensate Drain Valves

Centrifugal Vacuum Concentrators and Cold Traps

Owner s Manual. Terpene Trap CF 1000

Cool IR. Model C104 - Cooling System. Instruction Manual

QSV Series Vacuums an EnPro Industries company QUINCY QSV SERIES ROTARY SCREW VACUUM PUMPS 7.5 HP TO 200 HP

Varian, Inc. Vacuum Technologies. Diffusion Pumps. Features and Benefits 2-3. Typical Applications 4-5. Pump Models Fluids

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Equipment Designed for Industrial Applications

HYDROPONICS INDOOR GARDENING PRODUCTS

Used Fluid Handling Portable Used Oil Gravity Drains

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

PILOT-15 CENTRIFUGAL MOLECULAR DISTILLATION SYSTEM

SECTION AIR COMPRESSORS AND ACCESSORIES

Owner s Manual Therma-Stor II Heat Recovery System

CNC Series Refrigerated Air Dryer CFM

Refrigerant Recovery Unit, Model RRU134

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

S-Series Screw. The nnovation. leader

Using the Model 1500 Portable Chilled Mirror Hygrometer

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

Waveguide Dehydrators

Portable Vacuum Systems and Accessories Developed with Innovative Features for Ease of Use High Quality Electric and Pneumatic Models

Transcription:

005/006 Catalog Welch OEM, Industrial & Refrigeration Catalog High Vacuum Rotary Vane Pumps Dry (oil-free) Vacuum Pumps Refrigeration Vacuum Pumps Components, Traps & Gauges

OEM, Refrigeration & Industrial Catalog Welch Application Certified The business of Welch Rietschle Thomas is serving your vacuum application needs. For over 00 years, Welch has been supplying pumps for your vacuum applications. Welch has developed an in-depth knowledge from these years of experience on selecting the correct vacuum pump mechanism and modifying the vacuum mechanism to meet particular application needs. Our reasons for doing this are as follows: ) most cost effective solution; ) built-in health and safety considerations; ) extended service interval with correct pumping mechanism; 4) complete solution with necessary accessories and instructions and 5) provides peace of mind when selecting the correct pump since each is application certified. To learn more about our application specific pumps and systems, please see pages 6 to of this catalog or visit our web site at. We are proud to offer these products to serve your vacuum needs. CONTENTS Vacuum Pumps Compact Direct-Drive High Vacuum Pumps, & 8 DUOSEAL Rugged Belt-Drive Vacuum Pumps 4, 5 & 9 CHEMSTAR Pumps & Accessories for Corrosive Gases 6 & 7 OEM Dry (Oil-Free) Vacuum Pumps 0 & Standard Duty Dry Vacuum Pumps & Chemical Duty Dry Vacuum Pumps 4 & 5 Dry Rotary Vane Low Vacuum Pumps & Systems 8 Application Specific Information Summary Chart of Common Pump Applications Aspiration/Filtration Systems 6 LCMS Vacuum Pump 7 Low Pressure Refrigerant Recovery 9 Commercial & Industrial Refrigeration Service 0 Refrigeration & Air Conditioning Manufacturing Vacuum Components & Service Kits Vacuum System Connectors & Accessories 4 Exhaust Filters & On/Off Foot Switch 5 Foreline Traps & Hose Adapter Kits 6, 7 Vacuum Pump Oils 8 QUICKCHANGE Oil Change System 8 Vacuum Regulators, Vacuum Gauges 9 Service Kits 9-0 Pumping Speed Curves Index of Catalog Numbers Ordering, Service & Trademarks See our online catalog for additional information, U.S.A. list prices, and repair part information. Welch Rietschle Thomas, 005. All rights reserved. Printed in U.S.A.

Common Applications for Welch Vacuum Pumps & Systems Degassing Heat Treating Freeze Drying Lighting Picture Tube Refrigeration Manufacturing Refrigeration Service Crystallizers Optical Coating Metallizing Evaporators Vacuum Holding Vacuum Distillation Oil Purification Vacuum Coating Pharmaceutical Packaging Altitude Chambers Vacuum Chamber Glove Boxes Laser Technology Semiconductor Automotive Manufacturing Scientific Instrumentation Physics/Materials Research Food Processing Sterilization Vacuum Ovens Aspiration Filtration Gel Drying Concentrator Cell Harvester Vacuum Manifold Tissue Culture Aspiration Rotary Evaporation Transfer Line Glove Box Turbo Backing Diffusion Pump Backing Annular Space Schlenk Line Vacuum Oven Rice Porosity Neon Tube Manufacturing Aluminizer Laboratory Automation Transfer Chambers Vacuum Chucking Water Aspirator Replacement

Compact Direct Welch Vacuum Pumps Lightweight, Compact, High Performance Pumps Suited For: General Vacuum Work Heat Treating OEM Instrumentation Replacement Pumps for Instruments and Equipment 8890A 8905A 8907A/89A/897A (see note ) Specifications TWO-STAGE VACUUM PUMPS. Welch Model 8890 8905 8907 89 897 890 Free Air Displacement CFM (L/min) @ 60Hz.().8(5).6(7).8(08) 6.(7) 7.7(8) m /hr (L/min) @ 50Hz.6(6).6(4).7(6) 5.4(90) 8.6(44) 0.9(8) Ult. Pressure, Torr (mbar). x 0 (0.) x 0 (0.007) x0-4 (0.000) x0-4 (0.000) x0-4 (0.000) x 0 4 (0.0004) Ult. Pressure, microns Hg 00.0 0. 0. 0. 0. Sound Level, dba 58 5 50 50 50 54 Motor/Pump Speed (60Hz) 450 450 75 75 75 75 Motor Horsepower (watts) /4(90) /4(90) /(70) /(70) /(70) /(70) Oil Capacity, qt. (liters) 0.48(0.45) 0.4(0.4).0(0.95) 0.9(0.86) 0.9(0.86).(.) Tubing Needed, I.D. in. (mm) /8 /6, 7/6 7/6, /6 7/6, /6 7/6, /6 9/6, /6 (0) (5, ) (, 0) (, 0) (, 0) (4, 0) Intake Connection. (thread) Barb (/4 in NPT) UNIBARB (/4-0) UNIBARB ( /8-0) UNIBARB ( /8-0) UNIBARB ( /8-0) UNIBARB ( /8-0) Exhaust Connection. /4-0 /4-0 -0-0 -0-0 Weight, lbs (kg) 4.5(.) 4.5(.) 40(8) 4(8) 4(9.5) 58.5(6.6) Overall Dimensions L in. (cm) 4.5(6.8) 4.(5.9) 8.5(47.) 8.5(47.) 8.5(47.) 0.5(5.) W in. (cm) 5.() 5.() 6.5(6.5) 6.5(6.5) 6.5(6.5) 7.(7.9) H in. (cm) 8.4(.) 8.4(.) 9.6(4.) 9.6(4.) 9.6(4.) 0.7(7.) Ship Weight, lbs (kg) (5) (5) 55(5) 55(5) 60(7.) 7(.) Shipping Carton Dimensions.5 x.5 x 6.5 x.5 x 6 4 x 5.8 x 4 4 x 5.8 x 4 4 x 5.8 x 4 4 x 5.8 x 4 L x W x H in. (cm) (54.6 x.8 x 40.6) (54.6 x.8 x 40.6) (6 x 40. x 5.6) (6 x 40. x 5.6) (6 x 40. x 5.6) (6 x 40. x 5.6) 4, 5, 6. Ordering Information Catalog Number Wired for 5V, 60Hz, Ph 8890A 7,8. 8905A 8907A 89A 897A 890A with N. American 5V Plug Wired for 0V, 50Hz, Ph 8890C-0 7,8. 8905C-0 8907C-0 89C-0 897C-0 890C-0 with Cont. Euro. (Schuko) Plug Wired for 0V, 60Hz 8. 89C-0 897C-0 with N. American 0V Plug Wired for 5V, 60Hz, Ph 8905B-4 8907B-4 89B-4 897B-4 890B-4 with N. American 5V Plug & ISO NW inlet flange 5 Notes:. Models 8905, 8907, 89, 897, 890, and 895 should not be operated continuously at pressures above 0 Torr. Ultimate pressure measured with a trapped McCleod gauge.. UNIBARB : Convenient inlet barb connection accepts two sets of tubing ID (see page ).. Cat. nos. 8890A & 8890C-0 includes an exhaust filter; not included with any other model. 4. All single phase motors have overload protection. 5V, 60Hz models are CSA approved. 5. NW inlet flange replaces UNIBARB on these Cat Nos. Cat. No. 8905B-4 comes w/nw 6 inlet flange. Cat. Nos. 8907B-4, 89B-4, 897B-4 & 890B-4 comes w/nw 5.

Drive Vacuum Pumps Accessories and Oil Exhaust Filter A replaceable filter element captures oil mist from the exhaust port of the pump and reduces pump noise. Pump Model Cat. No. 8890, 8905 47 8907, 89, 897 47P-7 890, 895 47P-0 890A 895A Exhaust Oil Recycler Use when pumping continuously above Torr. Captures oil mist from the pump, and returns collected oil to the pump via a gas ballast connection. SPECIAL APPLICATION SYSTEMS 895 GEM System 8. For Harsh Chemicals 9..(0).() 6.(7) 6(67).6(6) 8.6(44) 4 x 0 4 (0.0005) x0 - (0.) x0 - (0.0) 0.4 00 0. 55 58 50 75 450 75 /4(560) /4(90) /(70).(.) 0.48(0.45).4(.) 9/6, /6 /8 7/6, /6 (4, 0) (0) (, 0) UNIBARB ( /8-0) Barb (/4 in NPT) UNIBARB ( /8-0) -0 /4-0 -0 69(.) 7.5(.5) 55(5).(5.8) 4.5(6.8) 8.6(47.) 7.(7.9) 5.().5(9.) 0.7(7.) 4.(6.) 9.6(4.4) 74(.6) 7(6.8) 70(.8) 4 x 5.8 x 4.5 x.5 x 6 5 x 8.5 x 4 (6 x 40. x 5.6) (54.6 x.8 x 40.6) (6.5 x 47 x 5.6) Pump Model Cat. No. 8890 (GEM) 46B 8905 46H 8907, 89, 897, 46C 890, 895 Dry Ice/Liquid Nitrogen Trap Recommended to protect pump from condensable vapors. Use either dry ice slurry or LN in the quart center well. Accepts 7/6 I.D. hose. See pg. 7. Pump Model Cat. No. 8890, 8905, 8907, 40H-4 89, 897, 890, 890 Premium Vacuum Pump Oil Higher viscosity formula that resists breakdown at higher RPM and temperatures of direct drive vacuum pumps. Size Cat. No. Liter 8995P- Gallon 8995P-5 5 Gallon 8995P-0 55 Gallon 8995P-5 895A 8890A-70 897A-80 0. 895C-0 8890C-7 897C-80 Gold Vacuum Pump Oil Specially formulated oil for challenging applications. This highly saturated synthetic oil is resistant to breakdown at higher temperature and is highly stable in chemical environments. Size Cat. No. Liter 8995G- Gallon 8995G-5 5 Gallon 8995G-0 55 Gallon 8995G-5 6. 0V, 50 Hz models which are provided with CE mark. 7. Cat No. 46B Exhaust Oil Recycler is recommended when operating the GEM at pressures of Torr or higher. 8. GEM System includes 46B Exhaust Oil Recycler & 4 Vacuum Regulator. 9. System comes with integral oil filtration system. See page 8 for more details. 0. Order 897C-80 and cord set 8906M for 0V, 60Hz, Ph.

DUOSEAL Vacuum Pumps Rugged Belt Drive Long Service Life Due To Low Pump RPM In Demanding Applications Such As: Freeze Drying Refrigeration Service Heat Treating Degassing Vacuum Distillations Vacuum Drying 99N-0 400B-0 405B-0/40B-0 Specifications TWO-STAGE VACUUM PUMPS. Welch Model 400 405 40 76 97 Free Air Displacement CFM 0.9. 5.6 0.6 7.7 L/min 5 90 60 00 500 Ult. Pressure, Torr(mbar). x 0 4 (0.000) x 0 4 (0.000) x 0 4 (0.000) x 0 4 (0.000) x 0 4 (0.000) Ult. Pressure, microns Hg 0. 0. 0. 0. 0. Gas Ballast Yes Yes Yes Yes Yes Pump RPM 580 55 55 55 400 Motor Horsepower (watts) /(50) /(70) /(70) (750) (750) Oil Capacity, qt. (liters) 0.6(0.59).5(.).5(.).5(.4).5(.) Tubing Needed, I.D. in. 7/6() 7/6() /6() /6() -5/8(4) Intake, Nipple Thread /4-0 -0-0 -0.75-0 Exhaust, Thread Type /4-0 -0-0 -0.75-0 Weight, lbs (kg) 58(6) (5) (5) 56(7) 05(9) Overall Dimensions L in. (cm) 7.8(45.) 0(5) 0(5) 0(5) 6(66) W in. (cm) 9(.9) (0.5) (0.5) 4.(5.9).7(4.8) H in. (cm).6(.) 5(8.) 5(8.) 5.4(9) 8.8(47.6) Ship Weight, lbs (kg) 70(.8) (60) (60) 80(8.8) (96.8) Shipping Carton Dimensions 0.5 x.8 x 4.5.5 x 5.5 x 9.5.5 x 5.5 x 9.5 x 8 x 9 7. x 8 x L x W x H in. (cm) (5. x 5. x 6.8) (57. x 9.4 x 49.5) (57. x 9.4 x 49.5) (55.9 x 45 7x 48.) (69. x 45.7 x 55.9) Ordering Information,4. Catalog Number Wired for 5V, 60Hz, Ph 400B-0 6. 405B-0 6. 40B-0 6. 76B-0 97B-0 with N. American 5V Plug Wired for 0V, 60Hz, Ph 400C-0 405C-0 40C-0 with N. American 0V Plug Wired for 0V, 50Hz, Ph 400C-0 405C-0 40C-0 76C-0 97C-0 w/cont. Euro. (Schuko) Plug Explosion Proof Motor, 400W-0 5. 405W-0 5. 40W-0 5. 5V, 60Hz 4 -Phase Motor 0V, 40M-0 76M-0 97M-0 460V, 60Hz Notes:. Two-stage pumps should not be operated continuously at pressures above 0 Torr. Ultimate pressure measured with a trapped McCleod gauge.. One-stage pumps should not be operated continuously at pressures above 50 Torr.. All 5V and 0V single phase motors include thermal overload protection. 4. Models 400C-0, 405C-0 and 40C-0 provided with CE marking.

V acuum Pumps Accessories and Oil Exhaust Filter A replaceable filter element captures oil mist from the exhaust port of the pump and reduces pump noise. Pump Model Cat. No. 99, 400 47 76, 40, 405 47P-0 97, 74 47P-0 76B-0 97B-0/74B-0 ONE-STAGE VACUUM PUMPS. w/o plate w/bell jar plate 74 99 99N.. 650 5 5 x 0 4 (0.000).5 x 0 (0.09).5 x 0 (0.09) 0. 5 5 Yes No No 50 750 750 -/(0) /(50) /(50).5(.) 0.5(0.47) 0.5(0.47) -5/8(4) 7/6() 7/6().75-0 /4-0 /4-0.75-0 /4-0 /4-0 Exhaust Oil Recycler Use when pumping continuously above Torr. Captures oil mist from the pump and returns it to the pump via a gas ballast connection. Pump Model Cat. No. 400 46H-0 76, 40, 405 46C-0 Dry Ice/Liquid Nitrogen Trap Recommended to protect pump from condensable vapors. Use either dry ice slurry or LN in the quart center well. Accepts 7/6 I.D. hose. See pg. 7. Pump Model Cat. No. 400, 405, 40, 40H-4 76, 99 0(00) 5() 6(8.6) 6(66) 7(4.) 7(4.).7(4.8) 9(.9) 9(.9) 8.8(47.6) 0(5.4) 0(5.4) 5(97.7) 6(8.) 74(.6) 7. x 8 x 0.5 x.8 x 4.5 0.5 x.8 x 4.5 (69. x 45.7 x 55.9) (5. x 5. x 6.8) (5. x 5. x 6.8) DUOSEAL Vacuum Pump Oil Tested to high vacuum levels, this oil meets rigid requirements for vapor pressure, stability, and viscosity. Size Cat. No. Quart 407K- Gallon 407K-5 5 Gallon 407K-0 55 Gallon 407K-5 74B-0 5. 99B-0 99N-0 74C-0 5. 99C-0 74M-0 5. Conduit wiring installation required. No cord, plug or switch provided. See page 9 for more details. 6. CSA approved models are 400B-80, 405B-80 and 40B-80. Gold Vacuum Pump Oil Specially formulated oil for challenging applications. This highly saturated hydrocarbon oil is resistant to breakdown at higher temperature and is highly stable in chemical environments. Size Cat. No. Liter 8995G- Gallon 8995G-5 5 Gallon 8995G-0 55 Gallon 8995G-5 5

CHEMSTAR Pumps For Corrosive Gases CHEMSTAR Vacuum Pumps For Pumping Corrosive Gases HCl O H SO 4 HBr HOAC SO x Br F CCO H H S Cl CH O HNO SF 6, CF 4 Fragments and other gases 40N-0 The Five Defining Features Needed For Pumping Corrosive Gases. High Contamination Tolerance Contaminants diluted Fewer moving parts Top oil feed for cleaner oil. Vital Parts Corrosion Resistant Fluoroelastomer seals and gaskets Metal vanes Stainless steel valves, etc. Teflon coated oil case Specifications.. Reduced Frictional Wear Less than 580 RPM vs. typical 750 RPM direct drive 4. Nitrogen Purge Standard Degases and cools oil 5. Easy Attachment of Accessories Complete accessory package for corrosive gases Welch Model 400N 40N 76N Free Air Displacement CFM 0.9 5.6 0.6 L/min 5 60 00 Ultimate Pressure, Torr(mbar). x0 4 (0.000) x 0 4 (0.000) x 0 4 (0.000) Gas Ballast Yes Yes Yes Pump RPM 580 55 55 Motor Horsepower (watts) /(50) /(70) (750) Oil Capacity, qt. (liters) 0.6(0.59).5(.).5(.7) Tubing Needed, I.D. in. 7/6() /6() /6() ISO Exhaust & Intake Flange NW 6 NW 5 NW 5 Dimensions L x W x H in. (cm) 7.8 x 9 x.6 9. x 4. x 5.4 9. x. x 5.6 (45. x.9 x ) (49 x 5. x 9.) (49 x. x 9.6) Weight, lbs (kg) 58(6) (5) 56(7) Ship Weight, lbs (kg) 7(.) (60.5) 8(8.) Shipping Carton Dimensions 0.5 x.8 x 4.5.5 x 5.5 x 9.5 x 8 x 9 L x W x H in. (cm) (5. x 5. x 6.8) (57. x 9.4 x 49.5) (59.5 x 45 x 48) Ordering Information,,5. Catalog Number Wired for 5V, 60Hz, Ph 400N-0 40N-0 76N-0 with N. American 5V Plug Explosion Proof Motor 400N-90 4. 40N-90 4. 5V, 60Hz, Ph Wired for 0V, 60Hz, Ph 40N-60 76N-60 with N. American Plug Wired for 0V, 50Hz, Ph 400N-50 6 40N-50 6 76N-49 with Cont. Euro. (Schuko) Plug. 6 Wired for 00V 50/60Hz, Ph 400N-5 40N-5 76N-5 for Japan Notes:. CHEMSTAR pump should not be operated continuously at pressures above 0 Torr. Ultimate pressure measured with a trapped McCleod gauge.. All single phase motors have overload protection.. Conduit wiring installation required. No cord, plug or switch provided. 4. Hinged clamp, centering ring assembly and hose adapter are included with all CHEMSTAR Pumps. 5. Standard filter option possible if the exhaust flange is removed, but not chemically resistant. 6. Units supplied with CE marking.

Protective Accessories For Corrosive Gases Protective Accessories For CHEMSTAR PUMPS Acid Neutralization Trap Hermetically Sealed Oil Mist Eliminator Make The Clear Choice Heavy Corrosive Gas Loads Contaminated Exhaust Oil Mist Particulates In Gas Streams Acid Neutralization Traps The Acid Neutralization Trap contains a large alkaline element cartridge to neutralize hydrous acids before they enter the vacuum pump. The element changes from white to bluish-transparent when spent and can be observed through the transparent trap body. Dimensions: 40H-, 8 W x 9 H; 40H-0, 8 W x H. (See CHEMSTAR application booklet for specific recommendations for use.) CATALOG NUMBER PUMP CONNECTOR REPLACEMENT ISO SIZE CAPACITY TRAP KIT FOR TRAP. ELEMENT NW 6 To CFM 40H- 40K-6 40E-0 NW 5 To CFM 40H-0 40K-5 40E-0. Includes hinge clamp, centering ring and elbow. Use with CHEMSTAR vacuum pumps. Hermetically Sealed Oil Mist Eliminators Make The Clear Choice When attached to an effective exhaust line, the hermetically sealed oil mist eliminator prevents corrosive vacuum pump exhaust gases from escaping into the room. It also coalesces oil mist from the pump exhaust and allows it to drain back into the pump. Coalescing the oil mist prevents loss of oil and the frequent need to add expensive vacuum fluids. Stainless steel construction with borosilicate microfiber element and flouroelastomer gaskets. Requires but does not include pump adapter kit. Dimensions of cat no. 46D: 5 W x 7-/4 H; 46F, 5 W x -/8 H. 46D exhaust port accepts /6 I.D. hose. CATALOG NUMBER USE WITH MIST PUMP REPLACEMENT PUMP MODEL ELIMINATOR ADAPTER KIT ELEMENT 400N 46D 46E-0 47Y-05 40N, 76N 46D 46E-0 47Y-05 8995G- 7

Special Configuration Direct Drive Pumps Pump With Explosion Proof Motor Explosion proof motor, Class I Group D, Class II Groups E,F,G Conduit wiring installation required. No Cord, plug or switch provided 895W UNIBARB Inlet Connection Cat. No. Description. 897W 7L/min, x0-4 Torr(. x 0-4 mbar), 5/0V, 60Hz, Ph 895W 0L/min, 4x0-4 Torr(5. x 0-4 mbar), 5/0V, 60Hz, Ph Note: See pages & for more details. Pump With ISO Inlet Flange NW 5 inlet connection Isolation & anti-oilsuckback solenoid valve 890B-4 Gas ballast Cat. No. Description. 8905B-4 5L/min, x0 - Torr(.7 x 0 - mbar), 5/0V, 60Hz, Ph 897B-4 7L/min, x0-4 Torr(. x 0-4 mbar), 5/0V, 60Hz, Ph 890B-4 8L/min, x0-4 Torr(4 x 0-4 mbar), 5/0V, 60Hz, Ph Note: See pages & for more models and details. Pump With Integral Oil Filtration System Continuous neutralization of acids in oil 897B-80 Gold oil resistant to chemical attack Mist eliminator included Cat. No. Description. 897B-80 7L/min, x0 - Torr(. x 0 - mbar), 5/0V, 60Hz, Ph 897C-80 Same as 897A-80 except 4L/min @50Hz, 0V with universal IEC connector and detachable Schuko line cord, CE Note: See page for more details. GEM Pump With Vacuum Regulation Inner Gear Outer Gear Vacuum regulation with dial vacuum gauge Pump operates from 0. Torr to 760 Torr 8890A-70 Gear pumping mechanism very tolerant of vapors Cat. No. Description. 8890A-70 L/min, 0.Torr(0. mbar), 5V, 60Hz, Ph with N. American 5V plug, CSA 8890C-7 Same as 8890A-70, except 6L/min, wired for 0V, 50Hz with cont. European(Schuko) plug, CE Note: See page for more details. 8

Special Configuration Belt Drive Pumps Pump With Explosion Proof Motor Explosion proof motor, Class I Group D, Class II Groups E,F,G* Conduit wiring installation required. No Cord, plug or switch provided 40W-0 Large oil reservoir dilutes contaminants *Cat. no. 40W-0 is Class I Group C,D, Class II Groups F,G Cat. No. Description. 400W-0 5L/min, x0-4 Torr(. x 0-4 mbar), 5/0V, 60Hz, Ph 405W-0 90L/min, x0-4 Torr(. x 0-4 mbar), 5/0V, 60Hz, Ph 40W-0 60L/min, x0-4 Torr(. x 0-4 mbar), 5/0V, 60Hz, Ph Note: See page 4 for more details. Pump With Bell Jar Plate Includes bell jar plate Delivers pressure of 5 PSIG 99N-0 One stage vacuum pump Cat. No. Description. 99N-0 5L/min,.5x0 - Torr(.9 x 0 - mbar), 5/0V, 60Hz, Ph Note: See page 5 for more details. DUOSEAL Pump Only Low pump RPM for long service life High contamination tolerance 400 Pump only, no motor, base or belt guard Cat. No. Description. 400 5L/min, x0-4 Torr(. x 0-4 mbar), pump only 40 60L/min, x0-4 Torr(. x 0-4 mbar), pump only Note: See pages 4 & 5 for more details. Additional pump only, cat. nos. 405(90L/min), 76(00L/min), 97(500L/min), 74(650L/min) & 99(5L/min). CHEMSTAR Pump Only, For Corrosive Gases Vital parts corrosion resistant Nitrogen purge standard Pump only, no motor, base or belt guard 400N Cat. No. Description. 400N 5L/min, x0-4 Torr(. x 0-4 mbar), pump only 40N 60L/min, x0-4 Torr(. x 0-4 mbar), pump only Note: See page 6 for more details. Additional pump only, cat. no. 76N, 00L/min, x0-4 Torr(. x 0-4 mbar). 9

OEM Dry(Oil-Free) Dry Diaphragm and WOB-L Piston Vacuum Pumps,,. Compact, Economical Oil-Free Pumps Suited For: Gas Analyzers Backing Hybrid Turbos Centrifuges Drying Degassing Distillation 85B-0 04B-0 06B-0 Specifications Welch Model 85. 04. 06. 090. 085. Free Air Displacement CFM (L/min) @ 60Hz.().(4).4(68).(88) 6.(76) m /hr (L/min) @ 50Hz.6(7).7(8).4(57) 4.4(7) 8.8(47) Ultimate Pressure, Torr (mbar) (.7) 9() 50(67) 5() 00() Maximum Vacuum, in. Hg 9.85 9.6 8.0 9.0 6.0 Mechanism Diaphragm Diaphragm Diaphragm Diaphragm Diaphragm Type of Duty. Chemical Chemical Chemical Chemical Chemical Motor Horsepower (watts) /5(50) /5(50) /5(50) /(70) /(70) Tubing Needed, I.D. in. (mm) /4(7) /4(7) /4(7) 7/6() 7/6() Intake/Exhaust Thread NPT /4 /4 /4 /8 /8 Weight (lbs.) (5.9) (5.9).9(5.9) (4.5) (4.5) Overall Dimensions L in. (cm) 0.5(6) 0.5(6) (79) 5.(89) 5.(89) W in. (cm) 5(7) 5(7) 4.8().(8).(8) H in. (cm) 7.5(89) 7.5(89) 6.8(7) 6.6(68) 6.6(68) Ship Weight, lbs (kg) 7(7.7) 7(7.7) 7(7.7) 7(6.8) 7(6.8) Shipping Carton Dimensions 4 x 4 x 4 4 x 4 x 4 4 x 4 x 4 4 x 5.5 x 4.5 4 x 5.5 x 4.5 L x W x H in. (cm) (5.6 x 5.6 x 5.6) (5.6 x 5.6 x 5.6) (5.6 x 5.6 x 5.6) (6 x 9.4 x 6.8) (6 x 9.4 x 6.8) Ordering Information,,. Wired for 5V, 60Hz, Ph with N. American 5V Plug 85B-0 04B-0 06B-0 090B-0 085B-0 Wired for 0V, 50Hz, Ph with IEC connection includes UK & Schuko Line Cords 85C-0 04C-0 06C-0 090C-0 085C-0 Wired for 00V, 50/60Hz, Ph with a plug 85C-05 04C-05 -------- -------- -------- Notes:. Models 85, 04, 06 and 8 are designed for placement within a system enclosure. Models 85, 04 and 06 handle harsh chemical vapors since designed with heads, diaphragms and valves made of fluorinated plastics.. Models 090 and 085 are designed with PTFE coated head, stainless steel valves and a PTFE liner over diaphragm.. Standard duty WOB-L piston vacuum pumps handle vapors of aqueous solutions including buffers, but are not recommended for pumping organic, acidic, and basic vapors. 0

V acuum Pumps 090B-0/ 085B-0 8B-0 56B-4 56B-0/ 580B-0/ 58B-4 567B-0 585B-0 8. 56. 56. 567. 580. 58. 585..(6).(60).(65).5(00).5(99).5(00) 7.(0).8(0) 6(50).4(57) 4.9(8) 4.9(8) 5.0(8) 0(68).5() 4(5) 9() 60(80) 9() 4(5) 60(80) 9.9 9.8 9.6 7.6 9.6 9.8 7.6 Diaphragm Piston Piston Piston Piston Piston Piston Standard Standard Standard Standard Standard Standard Standard /5(50) /(50) /(50) /(50) /(50) /(50) /(50) NW6 Flange /4(7) 4. /4(7) /4(7) /8(0) /8(0) 5. /8(0) /6 /4 /4 /4 /8 /8 /8 (5.9) 6.5(7.5) 6.5(7.5) 6.5(7.5).5(0.).5(0.).5(0.) 0.5(6).7(97).7(97).7(97).5(6).5(6).5(6) 5(7) 7.(8) 7.(8) 7.(8) 7.6(9) 7.6(9) 7.6(9) 7.5(89) 9.5(4) 9.5(4) 9.5(4).7(97).7(97).7(97) 7(7.7) 8(8.) 8(8.) 8(8.) 8(.7) 0(.6) 8(.7) 4 x 4 x 4.5 x.5 x 6.5 x.5 x 6.5 x.5 x 6 7 x 0.5 x.5 x 6. x 7.5 7 x 0.5 x (5.6 x 5.6 x 5.6) (54.6 x.8 x 40.6) (8. x 6.7 x 0.5) (8. x 6.7 x 0.5) (4. x 6.7 x ) (54.6 x 4.4 x 44.5) (4. x 6.7 x.) 8B-4 56B-4 56B-0 567B-0 580B-0 58B-4 585B-0 8C-4 56C-4 56C-0 567C-0 580C-0 58C-4 585C-0 -------- 56C-5 56C-05 567C-05 580C-05 58C-5 585C-05 4. Dual inlet flange ISO NW6 with /4 in.(7mm) hose barb supplied which will thread into NW6. 5. Dual inlet flange ISO NW5 with /4 in.(7mm) hose barb supplied which will thread into NW5.

Standard Duty Dry Compact, Economical Oil-Free Pumps WOB-L Piston Dry Vacuum Pumps. Suited For: Vacuum Drying Desiccating Aspiration Degassing Chamber Roughing 5B-0 5B-0/54B-0 546B-0 567B-50/56B-50 Specifications Welch Model 5 5 54 546 56 567 58 Free Air Displacement CFM (L/min) @ 60Hz 0.9() 0.76().(4).6(45).(60)).5(00).5(00) m /hr (L/min) @ 50Hz 0.55(9.).(8).7(8).(8).0(50) 4.9(8) 4.9(8) Ultimate Pressure, Torr (mbar) 9(9) 00() 70(9) 60(80) 5(6.7) 60(80) 5(6.7) Max Pressure PSIG (pascal) (. x 0 5 ) 00(0 6 ) 50(5 x 0 5 ) 00(0 6 ) Maximum Vacuum, in. Hg. 6 7. 7.6 9.8 7.6 9.8 Motor Horsepower (watts) /0(5) /8(9) /8(9) /4(90) /(50) /(50) /(50) Tubing Needed, I.D. in. (mm) /6(5) /4(7) /4(7) /4(7) /8(0) /8(0) /8(0) Intake/Exhaust Thread NPT /6 in. Hose /4 /4 /4 /4 /4 /4 Weight (lbs.) 5.7.7.8 6.5 6.5 4.5 Overall Dimensions L in. (cm) 7.6(9.4) 8.(0.6) 8.(0.6) 0(5.4) 7.(4.9) 5.0(8.) 7(4.) W in. (cm) 4.5(.4) 8.8(.4) 8.8(.4) 7.5(9.) 6.5(6.5) 0(5.4) 7.5(9.) H in. (cm) 7.5(9.) 0(5.4) 0(5.4) 9(.9) 0.5(6.7) 0(5.4) (0.5) Ship Weight, lbs (kg) 6(.7) 7(7.7) 7(7.7) 7(7.7) 4(0.9) 4(0.9) (4.5) Shipping Carton Dimensions x 9 x 9.5 5 x 0.5 x 5 x 0.5 x 5 x 0.5 x.5 x.5 x 6.5 x.5 x 6.5 x.5 x 6 L x W x H in. (cm) ( x.8 x 4.) (8. x 6.7 x 0.5) (8. x 6.7 x 0.5) (8. x 6.7 x 0.5) (54.6 x.8 x 40.6) (54.6 x.8 x 40.6) (54.6 x.8 x 40.6) Ordering Information,. Wired for 5V, 60Hz, Ph with N. American 5V Plug 5B-0. 5B-0 4. 54B-0 4. 546B-0 4. 56B-50 567B-50 58B-50 Wired for 0V, 60Hz, Ph with N. American 0V Plug 5C-0 4. 54C-0 4. 546C-0 4. Wired for 0V, 50Hz, Ph. with Cont. Euro.(Schuko) Plug 5C-0. 5C-0 4. 54C-0 4. 546C-0 4. 56C-50 567C-50 58C-50 Wired for 00V, 50/60Hz, Ph with a plug 5C-05. 5C-05 4. 56C-56 58C-56 Notes:. All models are recommended for pumping vapors of aqueous solutions including buffers, but not for acidic, basic or organic vapors or gases.. 50Hz units supplied with CE marking.

V acuum Pumps Accessories Vacuum Hose Thick walled hose for vacuum or pressure applications. Hose clamp information available on page. Pump Model Cat. No. 5, 54, 545, 56, 00-5 565, 58, 585 5 00-5 585B-50/58B-50 5B-75 55B-75 Aspiration/Filtration Systems include 6Ft. of tubing and two hydrophobic filters Aspiration/Filtration Systems 585 5 55 7.(0) 0.9().(4) 0(68) 0.55(9.).7(8) 60(80) 9(9) 70(9) (. x 0 5 ) Exhaust Silencer Exhaust silencers are installed in the exhaust port of the pump to reduce pump noise. Pump Model Cat. No. 565, 585 4C 56 4D 58 4E 0, 0, 00, 4B 05, 07 4B 4C 4D/4E 7.6. 7. /(50) /0(5) /8(9) /8(0) /6(5) /4(7) /4 /6 in. Hose /4 4.5 5.7. 7(4.).0(8) 4.8(7.5) 7.5(9.) 8.() 8.() (0.5) 0.0(5.5) 0.0(5.5) (4.5) (5) 4.8(6.7).5 x.5 x 6.5 x.5 x 6.5 x.5 x 6 (54.6 x.8 x 40.6) (54.6 x.8 x 40.6) (54.6 x.8 x 40.6) Replacement Jars Plastic (45C) or glass jar (45B) to replace the collection jar included with the pumps. Spare receiver kit (475K-0) includes a. L autoclaveable jar, 6Ft. of tubing and two hydrophobic filters. Pump Model Cat. No. 5, 546, 54 45C 56, 565, 58, 585 45B 050, 060, 070 5B-75, 5C-75 475K-0 55B-75, 55C-75 45B 475K-0 45C 585B-50 5B-75 55B-75 585C-50 5C-75 55C-75 5C-76 55C-76. Model 5 can deliver PSIG (. x 0 5 pascal). 4. Models 5, 54 and 546 come with vacuum (and pressure) regulator, vacuum (and pressure) gauge, silencer and water trap. Models 5 and 546 can deliver 00 PSIG (0 6 pascal). Model 54 can deliver 50 PSIG (5 x 0 5 pascal). Particulate, Hydrophobic In-line Filters The filters are an economical solution to protect your piston vacuum pump from fine particulates and aerosols to 0. microns in diameter. Made of Polypropylene housing, cat. no. 475K- fits /4 to /8 I.D. hose and cat. no. 475K- fit /4 I.D. hose. Made of SBS resin housing, model 475K- fits /8 to 7/6 I.D. hose. Pump Model Cat. No. Pore Size 5, 55, 5, 475K- 0.8 micron 54,546 56, 58, 56, 567 475K- 0.8 micron 56, 567 475K- 0. micron 475K- 475K- 475K-

Dry Diaphragm PTFE Vacuum Pumps. Chemical Duty Dry Compact, Corrosion-Resistant, Oil-Free Pumps Suited For: Distillation Desiccation Vacuum Filtration Aspiration Degassing 00B-0 0B-0 0B-0/00B-0 DRYFAST Specifications Welch Model 00 0 0 0 00 Free Air Displacement CFM(L/min) @ 60Hz 0.45(.7) 0.78() 0.78() 0.78().() m /hr(l/min) @ 50Hz 0.6(0.6).(8).(8).(8).6(7) Ultimate Pressure, Torr(mbar) 0(46) 00() 9() (.7) 9() Maximum Vacuum, in. Hg 5.5 6 9.6 9.85 9.6 Motor Horsepower (watts) /(6) /5(50) /5(50) /5(50) /5(50) Gas Ballast No No Yes Yes Yes Tubing Needed, I.D. in. (mm) /4(7) /4(7) /4(7) /4(7) /4(7) Intake/Exhaust Thread NPT /4 /4 /4 /4 /4 Weight (lbs.) 5.5(.4) 6.(7.4) 0(9.) 0(9.) 0(9.) Overall Dimensions L in. (cm) 6.(5) 0(5.4) 0(5.4) 0(5.4) 0(5.4) W in. (cm) 5.5(40) 7(7.8) 0(5.4) 0(5.4) 0(5.4) H in. (cm) 7.5(88) 6.9(7.5) 6.9(7.5) 6.9(7.5) 6.9(7.5) Ship Weight, lbs (kg) 8(.6) 0(9.) (0) (0) (0) Shipping Carton Dimensions 6 x.5 x 6 x.5 x 6 x.5 x 6 x.5 x 6 x.5 x L x W x H in. (cm) (40.6 x.8 x ) (40.6 x.8 x ) (40.6 x.8 x ) (40.6 x.8 x ) (40.6 x.8 x ) Ordering Information,4. Wired for 5V, 60Hz, Ph 00B-0 0B-0 0B-0 0B-0 00B-0 with N. Amer. 5V Plug Wired for 0V, 50Hz, Ph 00C-0. 0C-0. 0C-0. 0C-0. 00C-0. w/cont. Euro. (Schuko) Plug Wired for 00V 50/60Hz 0C-05 0C-05 0C-05 00C-05 for Japan Notes:. Corrosion resistant construction using flourinated plastics for handling aggressive vapors and gases.. 50Hz models supplied with CE marking.. Models 00, 0, 0, 0, 05, 05, 00, 0, 05 & 07. are constructed of PTFE heads, Kalrez /Chemraz valves and a PTFE coated, molded diaphragm. 4

V acuum Pumps Accessories Vacuum Regulator Connects to pump intake for easy regulation of vacuum level. Includes an easy to read dial gauge. All stainless steel. Pump Model Cat. No. 0, 0, 00, 05, 4D 07, 00, 0, 0 0B-0/0B-0 DRYFAST ULTRA 05B-0/07B-0 Inlet/Exhaust Separator Glass jar assembly that attaches to the pump intake or exhaust. Captures accidentally ingested liquids before they move into the pump. Capacity 0 ml. Pump Model Cat. No. 00, 0, 0, 4B 00, 05, 07, 05, 0, 0 0 05 07.().8(50).(64).6(7).5(4).(5) (.7) 80(06) 80(06) 9.85 6.7 6.7 /5(50) /5(50) /5(50) Yes No No /4(7) /4(7) /4(7) /4 /4 /4 0(9.) 0(9.) 0(9.) 0(5.4) 0(5.4) 0(5.4) 0(5.4) 0(5.4) 0(5.4) 6.9(7.5) 6.9(7.5) 6.9(7.5) (0) (0) (0) 6 x.5 x 6 x.5 x 6 x.5 x (40.6 x.8 x ) (40.6 x.8 x ) (40.6 x.8 x ) 0B-0 05B-0 07B-0 Vacuum Hose Thick walled hose for vacuum or pressure applications. Hose clamp information available on page. Pump Model Cat. No. 00, 0, 0, 00-5 00, 05, 07, 0, 0 On/Off Foot Switch Hands free on/off pump operation No adaptors or special connection needed Plug directly into the power source outlet All maintained models feature Push On-Push Off action Pump Model Cat. No. 00, 0, 0, 40A, (maintained on/off) 00, 05, 07, 40B, (momentary on/off) 0, 0, 5, 40C, (momentary on/off 55, 5, 54, with IEC connections for 546, 56, 567, 90-0V, 50/60Hz pumps) 58,585 40A-5V only 40B-5V only 40C-0V, 50/60Hz 0C-0. 05C-0. 07C-0. 0C-05 05C-05 07C-05 Pocket Torr Vacuum Gauge Gauges a range of vacuum in Torr from to 760. Easy calibration via the touch panel. Vaccum connection is /4 in. I.D. hose barb. Sensor type is capacitance. 4. All stand-alone pumps supplied with an exhaust silencer, loose hose barb for exhaust port and an installed intake hose barb. Range(Torr) Cat. No. to 760 540 5

Aspiration/Filtration Stations Compact Station for Aspiration & Pressure Transfer "Did you know that the most common reason for vacuum pump failure is ingestion of liquid into the pump mechanism? Pumping capacity L/min, vacuum to. Hg(9 mbar) Aspiration/Pressure Transfer Station Standard duty, oil-free station is an economical, portable solution for aspirating or filtering. Added accessories include. L autoclaveable collection receiver, hydrophobic inline filter, automatic shutoff and vacuum regulator to simplify use. All wetted parts are treated for corrosion protection from moisture. Recommended for aspirating aqueous solutions including buffers, but not for acidic, basic or organic vapors and gases. Cat. No. Description. 5B-75 L/min,. in. Hg (9 Torr), PSIG(.x0 5 pascal) 5V, 60Hz Ph with carrying handles, accepts /6 in. (5 mm) I.D. hose 5C-75 Same as 5B-75 except 9. L/min, 9 mbar, 0V, 50Hz, Ph, supplied with CE mark. Note:. See pages for more details. 5B-75 High Flow For Cell Culture Aspiration 5 Automatic shutoff when. L collection receiver full Pressure capability to PSIG(.x0 5 pascal) Pumping capacity 4 L/min, vacuum to 7. Hg(9 mbar) Automatic shutoff when. L collection receiver full Bleach resistant construction extends service life 4 55B-75 Cell Culture Aspiration Station Cell culture station, cat. no. 55B-75 (5V, 60Hz), 55C-75 (0V, 50Hz), is an economical, portable solution for aspirating tissue culture samples. A high flow, (4 L/min) WOB-L piston pump is the heart of this cell cultures aspiration station. Added accessories include a. L autoclaveable collection receiver, a hydrophobic inline filter, automatic shutoff and vacuum regulator to simplify use. All wetted parts are treated for corrosion protection from moisture. Recommended for aspirating aqueous and bleach solutions, but not for acidic, basic or organic vapors and gases. Cat. No. Description. 55B-75 4 L/min, 7. in. Hg (70 Torr), 5V, 60Hz Ph with carrying handles, accepts /4 in. (7 mm) I.D. hose 55C-75 Same as 55B-75 except 8 L/min, 9 mbar, 0V, 50Hz, Ph, supplied with CE mark. Note:. See pages for more details. Accessories For Aspiration/Filtration Stations Handheld pipette with various style tips available Spare autoclaveable collection receiver kit Variable on/off foot switch Model Description 475K-0 Handheld pipette, channel, stainless steel aspiration adapter 40mm, includes rubber for Pasteur pipette 475K-0 Spare receiver kit - Includes: 6 Ft tubing,. L autoclaveable receiver, and two hydrophobic filters 40B Variable on/off foot switch, 5V 60Hz 40C Variable on/off foot switch with IEC plug connection, 90-0V 50/60Hz Note:. See for full line of accessories and more information. 6

Cell Harvesting & Aeration Pumps High Flow for Cell Harvesting Vacuum to 7.6 Hg(80 mbar) Vacuum regulator for continuous vacuum level control and monitoring 567B-70 PTFE hydrophobic filter inhibits ingestion of aerosol or fluids into pump Standard Duty Dry Cell Harvesting System Standard duty, oil-free pumps provide continuous high throughput flow for cell harvesters. Pump comes with a vacauum gauge to monitor vacuum level, bleed valve to regulate vacuum level, hydrophobic filter (cat. no. 475K-) with 0. m PTFE membrane to prevent accidental ingestion of liquids/aerosol,a.5 ft.(70 cm) of /4 in. (7 mm) ID silicon tubing. Recommended for aspirating aqueous solutions including buffers, but not for acidic, basic or organic vapors and gases. Cat. No. Description. 567B-70 00 L/min, 7.6 in. Hg (60 Torr), 5V, 60Hz Ph 567C-70 8 L/min, 80 mbar, 0V, 50/60Hz Ph supplied with CE mark. Economical Source of Air for Aeration Quiet, linear diaphragm mechanism Continuous pressure to 4 PSI Oil-less 40B-0 Linear Diaphragm Compressor Linear diaphragm compressors employ a linear/vibrating armature to move a diaphragm to generate compressed air for aeration in life science and environmental applications. The unit is low in vibration, generates little heat, low power consumption, and is low in noise. The mechanism is continuous duty. Specifications Welch Model 40 40 460 478 Free Air Displacement CFM(L/min) @ 60Hz.4(5).0(56).(9).6(0) m /hr(l/min) @ 50Hz.45(9).4(47).8(76) 4.4(85) Max Pressure, PSIG (pascal) (x0 4 ) (x0 4 ) 4(4x0 4 ) (x0 4 ) Inlet thread NPT /8 /8 /8 /6 Tubing, I.D. in.(mm) /8(0) /8(0) /8(0) /8(0) Weight, pump only, lbs.(kg) 5.. 8. Dimensions of pump only LxWxH, in. 5.8x5.04x4.8 4.8x6.8x7.79 4.8x6.8x7.79 0.0x8.94x8.59,cm 4.8x.80x..7x7.5x9.79.7x7.5x9.79 5.4x.7x.8 Shipping weight, pump only lbs.(kg) 7(.) (5.9) 6(7.).(9.5) Ordering Information Wired for 5V, 60Hz, Ph with N. American 5V Plug 40B-0 40B-0 460B-0 478B-0 Wired for 0V, 50Hz, Ph 40C-0 40C-0 460C-0 478C-0 with cont. Euro.(Schuko) Plug Notes:. Supplied with CE marking 7

Dry Rotary Vane Low Vacuum Pumps & Systems (Oil-Free) Economical, lightweight design Extended Life Graphite Vane Design Suited For: Parts Handling Pick and Place Conveyor Lines Vacuum Chucking Case Set-Up Palletizers 80B-0/840B-0 Stand-alone Pump 840B-0/870B-0 Tank Mounted Pump Two Options Available: Option A: Stand-alone pump comes ready to use out of the box with handle, hose barb, inlet trap, external exhaust muffler, line cord and switch. Free Air Flow (SCFM) @ in. Hg, 60 Hz Cat. No. HP 0 5 0 5 0 5 8B-0 /..6.4 0.8 0. 840B-0 / 4.6.8.9. 0. 870B-0 /4 0 8. 6. 4.4.5 0.8 Option B: Simplex tank mounted pump comes with ASME code receiver, vacuum gauge, exhaust muffler, built-in inlet and exhaust filter and manual shut-off valve. A three position switch allows for on/off continuous duty or automatic on/off at a set vacuum level. Dimensions, in. (cm) Cat. No. A B C D F Wt., Lbs (kg) 840B-0 0(76.) 0.8(7.4) 0.5(5.) 6.75(7.).5(.8) 79(5.9) 870B-0 0(76.) 0.8(7.4).5(54.6) 6.75(7.).5(.8) 00(45.5) Specifications Welch Model 80 840 870 Free Air Displacement, CFM(L/min).(9) 4.6(0) 0.0(8) Ultimate Pressure, Torr (mbar) 5(67) 00() 00() Maximum Vacuum, in. Hg 5 6 6 Motor HP / / /4 Tubing, I.D. inch /4 /4 7/6 Inlet Connection, in. FNPT /4 /4 /8 Outlet Connection, in. FNPT /4 /4 /8 Tank on Simplex, gal. N/A 0 0 Weight, pump only, lbs.(kg) 4(5.4) 4(5.5) 54(4.5) Dimensions of pump only LxWxH, in..5 x 6.5 x 7.5 x 6.5 x 7 9. x 6.75 x 8.5,cm 54.6 x 6.5 x 7.8 54.6 x 6.5 x 7.8 49 x 7. x.6 Shipping weight, pump only lbs.(kg) 4(9.) 4(9.) 60(7.) Ordering Information. Stand-alone Pump, 5V, 60Hz, Ph 80B-0 840B-0 870B-0 Tank Mounted Pump, 5V, 60Hz, Ph 840B-0 870B-0 Notes:. Supplied with 5V N. American plug. 8

Refrigeration Recovery Pump Refrigerant Recovery Efficiency Of 99.8% Continuous discharge pressure to 0 PSIG (. x 05 Pascal) Pump shell rated to 00 PSIG (7.9 x 05 Pascal) Minimal loss of pumping efficiency below 9.9 inches Hg, (,000 microns Hg, Torr, mbar) CRR-A CAPTURE Pump The CAPTURE pump has been specifically designed for recovery and recycling systems that evacuate refrigerant systems to greater than 9.9 inches Hg( Torr, mbar) and boost refrigerant vapor to a holding tank. The recovery and recycling systems employing a CAPTURE pump are built for evacuation of R-, R- and R- chillers. The pump design has been in use in recovery and recycling systems for over 5 years. Pump oil separation and return is accomplished by attaching a standard float actuated oil return found in refrigerators. The oil separator is a proven technology that minimizes pump oil loss even for very large refrigerant systems. DUOSEAL pump oil, cat. no. 407K-, is recommended fluid to operate the CAPTURE pump. Specifications Welch Model CRR- Vapor Pumping Rate at atmospheric pressure CFM 0.6 L/min 00 Ultimate Pressure microns Hg 0 inch of Hg 9.9+ Torr(mbar) 0.0(0.04) Maximum Discharge Pressure, PSIG(Pascal) 0(7.9 x 0 5 ) Pressure Rating of Pump Shell, PSIG(Pascal) 00(0 6 ) Suction Connection, Female NPT Discharge Connection, Female NPT Oil Return Connection, in. 45 o Flare Fitting Size /4 Minimum Size of System Piping, NPT Oil Capacity, qts(l).5(.4) Motor RPM 75 Pump RPM 55 Full Load(amps, 5/0V).8/6.9 Locked Rotor(amps, 5/0V) 70/5 Overall Dimensions, LxWxH in.(cm) 9.5 x. x. (48.9 x. x 8.) Weight, lbs.(kg) (55.4) Shipping Weight, lbs.(kg) 6(6.8) Shipping Carton Dimensions x 4.8 x 8 L x W x H in.(cm) (55.9 x 7.6 x 45.7) Ordering Information Wired for 5V, 60Hz, Ph with N. Amer. 5V Plug Wired for 0V, 50Hz, Ph w/cont. Euro. (Schuko) Plug CRR-A CRR-B Notes:. For pump only, use cat. no. CRR-. 9

Commercial & Industrial Refrigeration Service Handles Harsh Absorption Chiller Servicing Low pump RPM High contamination tolerance Seals and gaskets for newest refrigerants DUOSEAL High Vacuum Pump DUOSEAL belt-drive high vacuum pumps are known worldwide for ruggedness and dependability. These pumps have large oil reservoirs for their pumping capacity to dilute contaminates coupled with low pump RPM to reduce friction and wear. Cat. No. Description. 40B-46 5.6 CFM (60 L/min), 0. micron Hg ( x 0-4 Torr, x 0-4 mbar) 5V, 60Hz Ph with carrying handles, /4 in. flare inlet fitting 76B-46 0.6 CFM (00 L/min), 0. micron Hg ( x 0-4 Torr,. x 0-4 mbar) 5V, 60Hz Ph, /4 in. flare inlet fitting 97B-46 7.7 CFM (500 L/min), 0. micron Hg ( x 0-4 Torr,. x 0-4 mbar) 5V, 60Hz Ph, -/ in. female NPT inlet fitting Note:. See pages 4-5 for more details. Lightweight For Rooftop Jobs Compact & lightweight High pumping capacity Seals and gaskets for newest refrigerants Welch Direct-Drive Vacuum Pump Welch direct-drive high vacuum pumps are lightweight with high capacity to get you on and off your rooftop job fast. Cat. No. Description. 890A-46 7.7 CFM (8 L/min), 0. micron Hg ( x 0-4 Torr, 4 x 0-4 mbar) 5V, 60Hz Ph, 58.5 lbs. (6.6 kg), /4 in. flare inlet fitting 895A-46. CFM (0 L/min), 0.4 micron Hg (4 x 0-4 Torr, 5. x 0-4 mbar) 5V, 60Hz Ph, 69 lbs. (. kg), /4 in. flare inlet fitting Note:. See pages - for more details. Pump Selection Guide For Refrigeration Service Application Tonnage Cat. No. Pump Capabilities Lithium Bromide 00-500 40B-46 Handles harsh salt-laden water vapor. Absorption Chiller 500-000 40B-46, 76B-46 Withstands accidental ingestion of liquid. 000-500 76B-46 Recirculates clean fraction of pump oil. Cold Storage 0-50 40B-46 Handles long pumpdown time effectively. 50-500 40B-46, 76B-46 Handles high water vapor loads. 890A-46, 895A-46 Draws a very deep vacuum. 500-000 97B-46, 895A-46 HCFC, CFC or 0-50 40B-46 Seals & gaskets won t break down in the Ammonia Chillers 50-500 40B-46, 76B-46 presence of R-, R-, R-, R-, 890A-46, 895A-46 R-, R-, R-4, R-50, R-50 or 500-000 97B-46, 895A-46 ammonia. Draws a very deep vacuum. Handles high water vapor loads. 0

Refrigeration & Air Conditioning Manufacturing Durability At The Deepest Vacuum Low pump RPM ensures long service life High efficiency pumping below 00 millitorr Few moving parts increase pump durability DUOSEAL High Vacuum Pump DUOSEAL belt-drive high vacuum pumps are known worldwide for durability and a long service. The key reason for the long life and high efficiency in pumping below 00 millitorr is the low pump RPM. Note:. See pages 4-5 for more details. Cat. No. Description. 400B-0 0.9 CFM (5 L/min), 0. micron Hg ( x 0-4 Torr,. x 0-4 mbar) 5V, 60Hz, Ph, accepts 7/6 in. tubing 40B-0 5.6 CFM (60 L/min), 0. micron Hg ( x 0-4 Torr,. x 0-4 mbar) 5V, 60Hz, Ph, accepts /6 in. tubing 76B-0 0.6 CFM (00 L/min), 0. micron Hg ( x 0-4 Torr,. x 0-4 mbar) 5V, 60Hz, Ph, accepts /6 in. tubing 97B-0 7.7 CFM (500 L/min), 0. micron Hg ( x 0-4 Torr,. x 0-4 mbar) 5V, 60Hz, Ph, accepts -5/8 in. tubing Note:. See pages 4-5 for more details. Small footprint Built-in isolation device ISO NW 5 inlet connection Welch Direct-Drive Vacuum Pump Welch direct-drive high vacuum pumps are compact with high capacity to occupy small floor space. These pumps come with isolation devices integral to the pump to prevent oil and air contamination in the event of a power failure. Cat. No. Description. 897B-4 6. CFM (7 L/min), 0. micron Hg ( x 0-4 Torr,. x 0-4 mbar) 5, 60Hz, Ph, ISO NW 5 inlet fitting 890B-4 7.7 CFM (8 L/min), 0. micron Hg ( x 0-4 Torr, 4 x 0-4 mbar) 5V, 60Hz Ph, ISO NW 5 inlet fitting 895B-4. CFM (0 L/min), 0.4 micron Hg (4 x 0-4 Torr, 5. x 0-4 mbar) 5V, 60Hz Ph, ISO NW 5 inlet fitting Note:. See pages - for more details. The A,B,C s of Vacuum Pump Selection A + B = C Coil Size Desired Flow Vacuum Needed Units Ton micron Hg(mbar) L/min Residential AC.5 50(0.07) 60 to 450 50(0.07) 50 to 40 Commercial Air Handling 5-0 500(0.7) 5 to 40 Appliance 0.5 00(0.4) 65 to 0 Leak Testing.5 500(0.7) 0 to 70

Vacuum System Connectors & Tubing ISO NW Inlet Connectors For High Vacuum Pumps Stainless steel with o-ring No sealant required for installation For pumps above listed serial number B PUMP ISO THREAD SIZE MODEL SERIAL NO. B CAT. NO. NW 6 /4-0 99 >646. 9F NW 6 /4-0 400, 400N >8069. 9F NW 5-0 405 >7770. 9G NW 5-0 80 >4. 9G NW 5-0 40, 40N >8. 9G NW 5-0 76, 76N >4594. 9G NW 40-0 74 >759.4 9H NW 40.75-0 97 >57.4 9H NW 6 /4-0 8905 All. 8905K-05 NW 5 /8-0 8907, 89, 897, All.4 8907K-05 890, 895 Exhaust Connectors For High Vacuum Pumps For adding an exhaust line to a pump Connectors for vacuum hose and ISO NW Hose Connector ISO Connector A HOSE CONNECTOR ISO CONNECTOR PUMP MODELS HOSE I.D. CAT. NO. THREAD SIZE ISO NW A CAT. NO. 99, 400, 8905, 8890 7/6 9J /4-0 NW 6. 9F 40, 80, 76, 890, /6 9K -0 NW 5. 9G 895, 8907, 89, 897, 405 74, 97-5/8 9L /4-0 NW 40.4 9H 405, 40 7/6 9M -0 NW 5. 9G UNIBARB Inlet Connectors For High Vacuum Pumps Accepts two sets of tubing ID Aluminum With inlet screen THREAD SIZE PUMP MODEL Hose I.D. CAT. NO. /4-0 400, 99, 8905 /6 & 7/6 8905K-06 /8-0 8907, 89, 897 7/6 & /6 8907K-06 /8-0 890, 895, 897 9/6 & /6 890K-06 Brass Hose Barb Brass For use with ISO to female pipe adaptors HOSE BARB THREAD HOSE. I.D. CAT. NO. /4 /4 NPT /6 and /8 9X 9X Dimensions are in inches

Vacuum System Connectors & Tubing Male NPT Pipe Inlet And Exhaust Adapters Black Pipe Adapt inlet and exhaust to NPT Thread PUMP MODEL MACHINE THREAD NPT MALE THREAD CAT. NO. 400, 99 /4-0 / 9N 80, 40, 76, 405-0 /4 9P Red Vacuum Hose Hose Clamps Very thick walled hose for vacuum or pressure applications Quick-acting clamp tightened by a thumbscrew actuated worm screw Hose comes in 5 ft. lengths(.5m) SPECIFICATIONS HOSE KIT CAT. NO. CLAMPS CAT. NO. I.D. WALL O.D. THICKNESS 5ft only 0ft only 5ft only 0ft only 5ft only 0/pkg. /6 5/6 /6 00-5 00-0 - - - 050 /4* /4 /4 00-5 - - - - 050 7/6 5/6 -/6 040-5 040-0 - - - 0540 5/8 /8 -/8 050-5 050-0 - - 050-5 0550 /6 /8-9/6 060-5 060-0 060-5 0560-0 - 0560 5/8 /6 080-5 080-0 - - - 0580 *Hose works with pumps that accept /8 in. I.D. hose. Hinged Clamps Aluminum Closure by wing and nut bolt B A ISO A B CLAMP WIDTH CAT. NO. NW 6.6.65 0.6 00 NW 5.965.950 0.6 00 NW 40.75.600 0.65 00 Centering Assemblies Replacement O-Rings A Centering Ring Assembly C O-Ring B Stainless steel centering ring with o-ring Replaceable Viton o-ring seal CENTERING RING ASSEMBLY REPLACEMENT O-RING ISO A CAT. NO. B C CAT. NO. NW 6 0.60 00 0.0 0.75 0480 NW 5 0.984 00 0.0.00 0480 NW 40.575 00 0.0.600 0480 Rubber Hose Adapters ISO NW to rubber vacuum hose Aluminum B A ISO HOSE I.D. A B CAT. NO. NW 6 7/6 0.65.65 504 NW 6 5/8 0.750.65 505 NW 5 /6 0.875.7 506 NW 40-5/8.6.7 508 Dimensions are in inches

Vacuum System Connectors & Tubing Female Pipe Adapters Flat Female stubs have /8 in. to /4 in. NPT Stainless steel Can be used with many gauge probes including Welch No. 55A and 56A (see page ) Can be used with brass hose barbs (see page 5) B A ISO NPT A B CAT. NO. NW 6 /8 0.6 0.50 506 NW 6 /4 0.6 0.50 506 NW 5 /8 0.88 0.50 506 NW 5 /4 0.88 0.50 506 NW 5 / 0.88 0.50 5064 Male Pipe Adapters Male stubs have /8 in. to /4 in. NPT Hex shank Stainless steel A B ISO NPT A B CAT. NO. NW 6 /4 0.8.6 505 NW 5 /8 0.88.6 505 NW 5 /4 0.8.6 505 NW 5 / 0.496.6 5054 NW 5 /4 5056 Blank-Off Flanges Stainless steel To close off unused parts B ISO B CAT. NO. NW 6 0.0 880 NW 5 0.0 880 90º Elbows Stainless steel Same size flange on both ports A ISO A CAT. NO. NW 6.50 80 NW 5.04 80 A Tees Stainless steel Same size flanges on all ports A ISO A CAT. NO. NW 6.50 840 NW 5.04 840 A Reducers F.57 F A Makes differing sizes of ISO flanges Stainless steel ISO F ISO F A CAT. NO. NW 5 NW 6 0.555 87 NW 40 NW 6 0.555 87 NW 40 NW 5 0.900 87 Dimensions are in inches 4

Exhaust Filters & On/Off Foot Switch Standard Exhaust Filters & Directional Exhaust Filters Filters oil mist from pump exhaust Easy replacement of element Reduces pump noise Filters to 0. micron particle size Screw-in type 47 STANDARD EXHAUST FILTERS DIMENSIONS CATALOG NUMBER REPLACEMENT USE WITH PUMP MODEL DIAMETER HEIGHT FILTER ELEMENT 8890., 8905, 99,.5.5 47 47L 400, 400N 8907, 89, 897.5 4.5 47P-7 47R 890, 895, 76, 40 5.0 6.5 47P-0 47G 405, 40N, 76N 97, 74 5.0 9.0 47P-0 47H-0 897A-80, 8947C-80.5 4.5 47P-7 47R. GEM (8890) includes 47 as standard equipment. Large, high capacity 60 Swivel outlet with tubing connector Screw-in type Continuously separates oil mist from the vacuum pump exhaust and by gravity returns the oil to the pump. 47A DIRECTIONAL EXHAUST FILTERS DIMENSIONS CATALOG NUMBER USE WITH OUTLET GASKET PUMP MODEL DIAMETER HEIGHT TUBE O.D. FILTER ELEMENT REPLACEMENT 8907, 89, 897, 890, 5.0 7.5.0 47A 47G 47A-0 895,76,80, 40, 405, 40N, 76N 74, 97 6.5 0.0.0 47B 47H 47B-0 400 47C-0 Exhaust Oil Recycler Exhaust oil recyclers are recommended for vacuum systems with continuous pressure of Torr ( mm Hg) or higher.. At these pressures, conventional exhaust filters quickly saturate. The Mist Eliminator System continuously separates oil mist from the vacuum pump exhaust and actively returns the oil to the pump. CAT. NO. VACUUM PUMP MODEL NO. 46B 8890 (GEM) 46H 8905 46C 8907, 89, 897, 890, 895 46H-0 400, 400N Exhaust Mist Eliminator shown 46C-0 76, 76N, 40, 40N, 405 installed on pump with oil return line.. CAUTION: Two stage vane vacuum pumps such as models 8905, 8907, 89, 890, 897, 895, 400, 40, 76, 405, 400N, 40N and 76N should not be operated continuously at pressures above 0 Torr. On/Off Foot Switch 40A Hands free On/Off pump operations No adapters or special connections needed Plugs directly into the power source outlet On/Off foot switches are compatible with selected dry vacuum pump models. Switches handle up to 5 amps. Cat. No. 40A & 40B come with a -prong U.S. Standard plug with 8 Ft. Cord, CSA, NEMA & UL Enclosure Type. Cat. No. 40C comes with a male and female IEC connections, 8 Ft. Cord, CE and plugs directly into the IEC connection on the pump. 40B PUMP MODEL CAT. NO. 00, 0, 0, 00, 05, 07, 40A (5V/60 Hz only, maintained On/Off) 0, 0, 5, 55, 5, 54, 40B (5V/60 Hz only, momentary On/Off) 546, 56, 567, 58, 585 40C (90-0V with IEC connections, momentary On/Off) 40C Dimensions are in inches 5

Foreline Trap Selection Foreline Traps For protection against contaminants in vacuum systems Foreline traps are used to prevent harmful substances generated or resident in vacuum systems from damaging vacuum pumps. Particulates can become lodged in a pump mechanism causing physical damage. Vapors can condense to liquids within the vacuum pump as a natural result of gas compression. Liquid water, solvents and acids can cause serious damage to a vacuum pump mechanism. (Refer to CHEMSTAR, pages 6 and 7 for work with corrosive gases). Foreline traps are also used to prevent oil backstreaming, the migration of oil molecules from vacuum pumps back into vacuum systems causing contamination of those systems. This is more likely to occur at vacuum levels of x 0 Torr (. x 0 mbar) or deeper that are maintained continuously over long periods of time. TRAP SELECTION TABLE Effectiveness Rating: *** Very Good ** Good * Fair N/R Not Recommended COAXIAL ACID NEUTRALIZATION COLD TRAP TRAPS TRAPS Stainless Steel Calcium Hydroxide Dry Ice Liquid Element Slurry Nitrogen TRAP APPLICATIONS Prevent Oil Backstreaming ** N/R *** *** Trap Water Vapor N/R N/R *** *** Trap Organics. N/R N/R *** *** Trap Acidic Vapors N/R *** * *** TRAP MAINTENANCE Time Interval To Replace Six Depends on Acid Element Months Vapor Load Need Only Clean Trap No No Yes Yes Refrigerant Hold Time 4 to 4 (Hours with no load) TRAP CHARACTERISTICS Trapping Mechanism Room Room Operating Temperature Temp Temp -79ºC -98ºC Limiting Pressure (Torr) 0-4 0-0 -4 0-5 Can Lower Pump Base Pressure Yes Yes Note:. Examples: paraffins, solvents, organic acids, alcohols. Application Note for Cold Traps Cold traps employing a dry ice slurry or liquid nitrogen are effective as long as the refrigerant level is maintained. If the trap warms up while the pump is running, all of the trapped condensables will be ingested by the vacuum pump, contaminating the oil. Cold traps must be cleaned out at the end of each day. If the pump is run overnight, the trapped condensables will ultimately be ingested by the pump as the trap warms up. Cleaning a Dry Ice Slurry/Liquid Nitrogen trap is easy. The steps are:. Turn off the pump;. Leak air into the trap;. Remove the center well and plexiglass ring to a hood. The center well can be washed off into a beaker or the condensables can be allowed to evaporate in the hood. 6

Foreline Traps & Hose Adapter Kits Dry Ice/Liquid Nitrogen Trap Hose barb connection accepts 7/6 in. ( mm) I.D. hose Removable quart center well for dry ice/isopropyl alcohol slurry (do not use acetone) or liquid nitrogen Visible trapping surface Cold temperature up to hours depending on vapor load with dry ice slurry Cold temperature up to hours depending on vapor load with liquid nitrogen TUBING IN/OUT TRAP REPL. SEAL NEEDED DIAM. HEIGHT DIAMETER OFFSET CAT. NO. CAT. NO. 7/6 I.D. 0 8.5 0.75.5 40H-4 5450 Tubing cat. no. 040-5 Coaxial Traps ISO NW flange connection Reduces oil backstreaming Stainless steel construction Easy replacement of elements Element must be ordered separate from trap ISO SIZE CAPACITY DIAM. HEIGHT. CAT. NO. NW 6 To 4 CFM (40 L/min).75 8.5 5400 NW 5 To CFM (40 L/min) 5.50 8.5 5400 Stainless steel element for ISO NW 6 Trap 549 Stainless steel element for ISO NW 5 549. Distance between ISO NW inlet and outlet connections. Acid Neutralization Trap ISO NW flange connection Calcium Hydroxide element Element changes from white to bluish-transparent when spent CATALOG NUMBER ISO REPLACEMENT PUMP CONNECTOR SIZE CAPACITY TRAP ELEMENT KIT FOR TRAP. NW 6 To CFM (57L/min) 40H- 40E-0 40K-6 NW 5 To CFM (40L/min) 40H-0 40E-0 40K-5. Includes hinge clamp, centering ring and elbow. Use with CHEMSTAR vacuum pumps. Hose Adapter Kits Hose Adapters Hose Valves Kits ensure proper sized tubing adaptors, and clamps for vacuum tight connections Kits include at least 5 ft(.5m) of thick walled rubber vacuum hose ADAPTER KITS APPLIANCE FOR PUMP MODELS PUMP INLET O.D. CONNECTOR O.D. CAT. NO. 8890 (GEM) /8 /4 and /8 40H- 8890 (GEM) /8 7/6 and / 40H-0 400, 405, 99, 8905 7/6 /4 and /8 40H-0 40, 80, 8907, 89, 897, 890, 895 /6 /4 and /8 40H-0 40H-0 Dimensions are in inches 7

Vacuum Pump Oils & Oil Change System Gold Vacuum Pump Oil Exceptionally low vapor pressure High stability in chemical environments No additives or inhibitors Recommended for Welch belt-drive and direct-drive pumps A double distilled synthetic hydrocarbon oil designed for excellent resistance when pumping corrosive gases or vapors. A synthetic base stock that has no aromatic compounds or sulfur which accelerate varnishing, sludging and carbon build-up when pumps are used to pump corrosives. Gold oil will give a longer service life and superior protection for the internal metal components of a pump in corrosive pumping applications compared to DUOSEAL and Premium Oil. Gold Oil offers excellent vacuum pressure in both belt-driven and direct-driven vacuum pumps over time. Gold Oil is miscible with conventional hydrocarbon oils and can be used without rebuilding the pump. The oil is clear and colorless. CAT. NO. 8995G- 8995G-5 8995G-0 8995G-5 SIZE Liter Gallon 5 Gallon 55 Gallon Premium Vacuum Pump Oil Low vapor pressure Designated for high RPM direct drive vacuum pumps No additives or inhibitors Recommended for Welch direct-drive vacuum pumps A triple-distilled hydrocarbon oil using severely hydrotreated base stock is designed to resist breakdown at higher RPMs and operating temperatures of direct-drive vacuum pumps. The hydrotreating virtually eliminates aromatics and sulfur to give good resistance to sludge and varnish formation overtime in corrosive environments. Premium enables direct-drive vacuum pumps to maintain the highest vacuum performance over time. The oil is light yellow. CAT. NO. 8995P- 8995P-5 8995P-0 8995P-5 SIZE Liter Gallon 5 Gallon 55 Gallon DUOSEAL Vacuum Oil Low vapor pressure Ideal viscosity for belt-drive vacuum pumps High consistency Recommended for DUOSEAL belt-drive pumps A specially fractionated oil for DUOSEAL belt-driven pumps is designed to ensure the highest vacuum performance. The oil is tested to high vacuum levels to meet rigid requirements for vapor pressure, vacuum level stability, and viscosity. DUOSEAL oil is famous for its quality and consistency. CAT. NO. 407K- 407K-5 407K-0 407K-5 SIZE Quart Gallon 5 Gallon 55 Gallon QUICKCHANGE Oil Change System Easy to use Pumps into container for easy disposal Eliminates spillage Drains pump oil in seconds A complete oil change system. Includes suction pump and two containers, an all in one convenient package. Saves time and eliminates mess during a pump oil drain and is easy to use. Insert the suction hose into the vacuum pump s oil fill port (Models 8890, 8905, 890 and 895 require a drain valve kit, cat. no. 575, not supplied), turn on the suction pump, and in seconds all of the pump s oil is transferred to a collection reservoir for easy disposal. A check valve closes when the collection reservoir is full. Includes two L containers and ft ( m) of connecting hose, in a sturdy plastic case with carrying handle. Overall dimensions: W x 0 L x H in. (0.5 x 76. x 0.5 cm). Weight: 0 lbs(4.5 kg). CAT. NO. VOLTAGE Drain valve kit needed for models 8905, 890, 895 480 5V, 60Hz, Ph 575 8

Vacuum Regulators, Vacuum Gauges & Service Kits Vacuum Regulators 4A Bench Mount PUMP MODEL CAT. NO. 00, 0, 0, 00, 05, 07 4A 0, 0, 56, 567, 58, 585 0, 0, 00, 05 4D 07, 00, 0, 0 8890 4 Model 4A connects to pump intake via hose for easy regulation of vacuum level. Position on bench top. Corrosion resistant construction. Requires /4 in. (7 mm) ID hose (cat. no. 00-5). 4 & 4D Pump Mount Dial Pressure & Vacuum Gauge Thermocouple Vacuum Gauges Model 4 & 4D replaces inlet barb and allows easy regulation of vacuum level. Includes an easy to read dial gauge. Cat. No. 4D-All stainless steel construction. Cat. No. 4-Brass Construction. CAUTION: Do not use with DUOSEAL, CHEMSTAR or Direct-Drive pumps. Dial Diameter Units of Measure Connection CAT. NO. in. O.D. in. Hg, cm Hg (Brass) /8 male NPT 760 in. O.D. Pascal (Brass) /8 male NPT 760.5 in. O.D. in. Hg, mm Hg (Brass) /4 male NPT 7600 in. O.D. in. Hg, kpa (Stainless) /8 male NPT 760 in. O.D. mbar/kpa (Brass) /8 male NPT 7604 in. O.D. psi/kgsm /8 male NPT 7605 in. O.D. kpa/psi /8 male NPT 7606 Inexpensive gauge for measuring vacuum level. Not an absolute pressure gauge. Gauge uses atmospheric pressure as reference. Vacuum measurement to low millitorr (micron) range Rugged, reliable thermocouple gauge sensor tube Gauges provide an accurate, reliable measurement of vacuum. Self-contained gauges with solid-state electronics for rapid response time, long life and low maintenance. Come with 0 to 0 VDC recorder output. The gauge sensor tubes are designed to assure maximum sensitivity over the entire vacuum range. Gauge sensor tube connected to system via /8" NPT thread. Each gauge comes with one sensor tube and one cable. Dimensions of 7 L x 5 D x 5.6 H (7.8 x.7 x 4.); Weight lbs(0.9 kg). Gauge Protective Trap Replacement Sensor Tube CAT. NO. Range(millitorr) Voltage CAT. NO. CAT. NO. 55 0 to 5000 5V, 60Hz Ph 55B 55A Standard Duty Dry Piston Pump Kits Pump Model Kit No. Description 5 5K-0 Service Kit 5K-0 One Head Service Kit, 5 54 54K-0 Service Kit 54K-0 One Head Service Kit, 54 546 546K-0 Service Kit 546K-0 One Head Service Kit, 545 5, 54, 545, 546 5K-04 Seal Service Kit 5K-05 Vacuum Reg Kit, in. Hg/cm Hg 5K-06 Pressure Reg Kit, kpa/psi 5K-07 Vacuum Reg Kit, kpa/mbar 5K-08 Vacuum Reg Kit, kpa/in. Hg 5K-09 Pressure Reg Kit, psi/cm Hg 580, 585 585K-0 Connecting Rod Assembly 585K-0 Valve Plate Assembly 585K-0 Two Head Service Kit, 585 585K-04 Seal Service Kit, 585 56/567 567K-0 Two Head Service Kit, 56 567K-04 Seal Service Kit, 56 56 56K-0 Two Head Service Kit, 56 56K-04 Seal Service Kit, 56 58 58K-0 Two Head Service Kit, 58 58K-04 Seal Service Kit, 58 All Models WOB-L Dry Pump 500K-04 Service Kit for Feet 9

Service Kits Chemical Duty Dry PTFE Diaphragm Pumps Pump Model Kit. No. Description 00 00K-0 One head service kit 0, 05, 0 0K-0 One head service kit, S/N <EG040000 05K-0 One head service kit, S/N >EG050000 06, 04, 00 05K-0 One head service kit 050 05K-0 One head service kit 05K-0 Tubing service kit for 050, S/N <EC0999 05K-06 Tubing service kit for 050, S/N >EC0900 0, 0 07K-0 One head service kit 060, 070 07K-0 One head service kit 05K-06 Tubing service kit Diaphragm Pumps Pump Model Kit No. Description 8 8K-0 Two head diaphragm and valve kit 085, 090 090K-0 One head diaphragm kit 090K-0 Valve plate service kit DUOSEAL Vacuum Pumps Pump Model Kit No. Description 400 400K-0 Minor repair kit, 400 400K-04 Major repair kit, 400 40 40K-05 Minor repair kit, 40 40K-06 Major repair kit, 40 405 405K-05 Minor repair kit, 405 405K-06 Major repair kit, 405 76 76K-05 Minor repair kit, 76 76K-06 Major repair kit, 76 97, 74 97K-07 Minor repair kit, 97 & 74 97K-08 Major repair kit, 97 & 74 99 99K-0 Minor repair kit, 99 99K-04 Major repair kit, 99 7 7K-05 Minor repair kit, 7 7K-06 Major repair kit, 7 CHEMSTAR Vacuum Pumps Pump Model Kit No. Description 400N 400K-09 Minor repair kit, Chemstar 400N 400K-0 Major repair kit, Chemstar 400N 40N 40K-09 Minor repair kit, Chemstar 40N 40K-0 Major repair kit, Chemstar 40N 76N 76K-09 Minor repair kit, Chemstar 76N 76K-0 Major repair kit, Chemstar 76N Direct-Drive Vacuum Pumps Pump Model Kit No. Description 8890 8890K-0 Minor repair kit, 8890 8905 8905K-0 Minor repair kit, 8905 8905K-0 Shaft seal repair kit, 8905 8907, 89, 897 897K-04 Minor repair kit, 8907, 89, 897 897K-05 Shaft seal repair kit, 897 890 895K-0 Minor repair kit, 890 895 895K-0 Minor repair kit 895 0

Pumping Speed Curves 8890, 8905, 890, 895 8907, 89, 897 Pumping Speed, Liters Per Minute 0 0 0 @ 60Hz 8905 895 890 8890 5 0.5 0.5 0. Cubic Feet Per Minute Pumping Speed, Liters Per Minute 0 0 0 @ 60Hz 8907 897 89 5 0.5 0.5 0. Cubic Feet Per Minute 0-4 0-0 - 0-0 -0 0 Pressure, Torr 0-5 0-4 0-0 - 0-0 Pressure, Torr 400, 400N,405,40,40N 76, 76N,97, 74 0 @ 50 & 60Hz 5 0 4 @ 50 & 60Hz 50 Pumping Speed, Liters Per Minute 0 0 40 & 40N 405 400 & 400N 0.5 0.5 0. Cubic Feet Per Minute Pumping Speed, Liters Per Minute 0 0 74 97 76 & 76N 00 5 0.5 Cubic Feet Per Minute 0-5 0-4 0-0 - 0-0 Pressure, Torr 0-5 0-4 0-0 - 0-0 0 0 0 Pressure, Torr 0, 0, 00, 0 56, 567, 58, 585 Pumping Speed, Liters Per Minute 0 0 0 0 @ 60Hz 00 0 0 0.5 0.5 0. 0.05 0.0 Cubic Feet Per Minute Pumping Speed, Liters Per Minute 0 0 0 0 0 58 56 567 585 5 0.5 0.5 0. 0.05 0.0 Cubic Feet Per Minute 0 0 0 0 0 Pressure, Torr 0 0 0 Pressure, Torr

Index of Catalog Numbers Cat. No. Page No. Cat. No. Page No. Cat. No. Page No. Cat. No. Page No. 74 5 405W-0 4, 9 07C-05 4 567K-04 9 74B-0 5 407K- 5, 8 0B-0 4 580B-0 74C-0 5 407K-5 5, 8 0C-0 4 580C-0 74M-0 5 407K-0 5, 8 0C-05 4 580C-05 76 4 407K-5 5, 8 0B-0 4 58B-4 76B-0 4, 4B 0C-0 4 58B-50 76B-46 0 4C 0C-05 4 58C-4 76C-0 4 4D 0K-0 0 58C-5 76K-05 0 4E 04B-0 0 58C-50 76K-06 0 45B 04C-0 0 58C-56 76K-09 0 45C 00B-0 4 58K-0 9 76K-0 0 46B 5 00C-0 4 58K-04 9 76M-0 4 46C 5 00C-05 4 585B-0 76N 6 46C-0 5 0B-0 5 585B-50 76N-0 6 46D 7 0C-0 5 585C-0 76N-49 6 46E-0 7 0C-05 5 585C-50 76N-5 6 46E-0 7 085B-0 0 585K-0 9 9F 46H 5 085C-0 0 585K-0 9 9G 46H-0 5 090B-0 0 585K-0 9 9H 47 5 090C-0 0 585K-04 9 9J 47A 5 40B-0 7 00 9K 47A-0 5 40C-0 7 00 9L 47B 5 40B-0 7 00 9N 47B-0 5 40C-0 7 0480 9P 47G 5 40C-0 7 0480 9X 47H 5 460B-0 7 0480 97 4 47H-0 5 460C-0 7 050 97B-0 4, 47L 5 478B-0 7 0540 97B-46 0 47P-0 5 478C-0 7 0550 97C-0 4 47P-0 5 500K-04 9 0560 97K-07 0 47P-7 5 5B-0 0580 97K-08 0 47R 5 5B-75,6 00-0 97M-0 4 47Y-05 7 5C-0 00-5 99 5 480 8 5C-05 00-5 99B-0 5 40E-0 7, 7 5C-75,6 040-0 99C-0 5 40E-0 7, 7 5C-76 040-5 99K-0 0 40H-0 7, 7 55B-75,6 050-0 99K-04 0 40H-0 7, 7 55C-75,6 050-5 99N-0 5, 9 40H- 7, 7 55C-76 050-5 400 4, 9 40H-4 7, 7 5B-0 060-0 400B-0 4 40H-0 7, 7 5C-0 060-5 400B-80 4,5 40H- 7, 7 5C-0 060-0 400C-0 4 40K-6 7 5C-05 060-5 400C-0 4 40K-5 7 5K-0 9 080-0 400K-0 0 4 9 5K-0 9 080-5 400K-04 0 4D 5, 9 5K-04 9 80 4 400K-09 0 4A 9 5K-05 9 80 4 400K-0 0 4B 5 5K-06 9 840 4 400N 6, 9 40A 5,5 54B-0 840 4 400N-0 6 40B 5,6,5 54C-0 87 4 400N-50 6 40C 5,6,5 54C-0 87 4 400N-5 6 475K-0 6 54K-0 9 87 4 400N-90 6 475K-0 6 54K-0 9 880 4 400W-0 4, 9 475K-0 546B-0 880 4 40 4, 9 475K-0 6 546C-0 504 40B-0 4, 9, 475K- 546C-0 505 40B-46 0 475K- 546K-0 9 506 40B-80 4, 5 475K- 546K-0 9 508 40C-0 4 475K- 56B-4 505 4 40C-0 4 475K- 56B-50 505 4 40K-05 0 475K- 56C-4 505 4 40K-06 0 55 9 56C-5 5054 4 40K-09 0 540 5 56C-50 5056 4 40K-0 0 55A 9 56C-56 506 4 40M-0 4 55B 9 56K-0 9 506 4 40N 6, 9 00B-0 4 56K-04 9 506 4 40N-0 6 00C-0 4 56B-0 506 4 40N-50 6 00K-0 0 56C-0 5064 4 40N-5 6 0B-0 4 56C-05 5400 7 40N-90 6 0C-0 4 567B-0 5400 7 40W-0 6, 9 05B-0 4 567B-50 549 7 405 4 05C-0 4 567B-70 7 549 7 405B-0 4 05C-05 4 567C-0 5450 7 405B-80 4, 5 06B-0 0 567C-05 575 8 405C-0 4 06C-0 0 567C-50 7600 9 405K-05 0 07B-0 4 567C-70 7 760 9 405K-06 0 07C-0 4 567K-0 9 760 9 Cat. No. Page No. 760 9 7604 9 7605 9 7606 9 8B-0 8C-0 85B-0 0 85C-0 0 85C-05 0 80B-0 8 840B-0 8 840B-0 8 870B-0 8 870B-0 8 8890A 8890A-70 8 8890C-0 8890C-7 8 8890K-0 0 8905A 8905B-4,8 8905C-0 8905K-0 0 8905K-0 0 8907A 8907B-4 8907C-0 89A 89B-4 89C-0 895K-0 0 897A 897A-80, 8 897B-4, 9, 897C-0 897C-80, 8 897K-04 0 897K-05 0 897W 8 890A 890A-46 8 890B-4, 9, 890C-0 895A 895A-46 0 895B-4, 9, 895C-0 895K-0 0 895W 8 8995G- 8 8995G-5 8 8995G-0 8 8995G-5 8 8995P- 8 8995P-5 8 8995P-0 8 8995P-5 8 CRR-A 9 CRR-B 9

Ordering, Service & Trademarks HOW TO ORDER From Welch Dealers: Welch Rietschle Thomas products can be ordered from authorized laboratory dealers. Please check the Welch web site at or call (847-676-8800) or fax for a list of Welch dealers in the United States, Canada, and other locations. Mail: Welch Rietschle Thomas 49 Illinois Ave. P.O. Box 9 Sheboygan, WI 508-009 Payment Terms: Net 0 days with approved credit; Mastercard, Visa or American Express are accepted for your convenience. Minimum Order: $50.00 From Welch in the U.S.A and Canada: To order your vacuum pumps, parts and accessories: Order: Online @ E-mail: welchvacuum@thomasind.com Fax: 90-45-497 Technical Assistance: Call: (847) 676-889 Fax: (847) 677-8606 Repair & Warranty Service: E-mail: serviceusa@rtpumps.com Fax: 40-74-448 Call: 40-7-400 8:00 a.m. to 4:0 p.m. Eastern Time WELCH REPAIR SERVICE For warranty or non-warranty repairs, a RA number is needed prior to returning product for inspection. All paid repairs come with a new pump warranty. All returns must come with a P.O. with approved credit or credit card number. An RA number is obtained by filling out a safety service form located on the Welch web site,. A Welch customer service representative will then call or fax you with the RA number and shipping instructions. The reason for the safety service form is that it contains information on what chemicals may have been ingested into the pump during its use. Worker safety rules require this information prior to a repairman examining the pump. WARRANTY This Welch Vacuum product is warranted to be free from defects in material and workmanship. The liability of Welch Rietschle Thomas under this warranty is limited to servicing, adjusting, repairing or replacing any unit or component part which in the judgment of Welch Rietschle Thomas has not been misused, abused or altered in any way causing impaired performance or rendering it inoperative. No other warranties are expressed or implied. The method of executing this warranty: servicing, adjusting, repairing or replacing shall be at the discretion of Welch Rietschle Thomas. Vacuum pumps that have been used for any period, however short, will be repaired under this warranty rather than replaced. The warranty is effective for one year from the date of original purchase when:. The warranty card has been completed and returned.. The product is returned to the factory or other designated service centers, freight prepaid.. The product in our judgment is defective through no action or fault of the user. If the product has become defective through misuse, abuse, or alteration, repairs will be billed regardless of the age of the product. In this event, an estimate of the repair costs will be submitted and authorization of these charges will be required before the product is repaired and returned. To reduce additional charges and delays either within or outside of the warranty period, contact Welch Rietschle Thomas @ (40) 7-400 for a return authorization number. Products without a return authorization number will be refused by our receiving department. Before shipping, properly pack the pump, insure it against loss or damage, and on the outside of the pump packaging and the packing slip write in the return authorization number. Pumps damaged due to improper packaging are the customer s responsibility. For Repair Service Inquiry: Email: serviceusa@rtpumps.com Fax: 40-7-448 Call: 40-7-400 8:00 a.m. to 4:0 p.m. Eastern Time TRADEMARKS The following are registered trademarks of Welch Rietschle Thomas: WELCH, DUOSEAL, GEM, CHEMSTAR, DRYFAST, DRYFAST ULTRA, CAPTURE. The following are trademarks: SELF-CLEANING DRY VACUUM SYSTEM, UNIBARB & GELMASTER WOB-L is a registered trademark of Rietschle Thomas. For service outside the U.S.A and Canada, contact your closest Rietschle Thomas sales office. See country directory on back cover. The following are registered trademarks of other companies: Teflon E.I. DuPont de Nemours & Co. Chemraz Greene, Tweed & Co.

Sales and Service Offices For Welch Rietschle Thomas USA, Canada, Latin America Welch Rietschle Thomas P.O. Box 8 Skokie, IL 60076-08 USA Phone: 847-676-8800 Fax (Technical): 847-677-8606 Fax (Orders): 90-45-497 Email: welchvacuum@thomasind.com Australia Rietschle Thomas Australia, Pty. Ltd. 0 Bearing Road, Seven Hills New South Wales Australia 47 Phone: 6 () 96 0 70 00 Fax: 6 () 96 0 79 55 Email: tiap@rtpumps.com Hong Kong/PRC Rietschle Thomas Hong Kong Units -5, 5th Floor, Metropole Square No. On Yiu St., Siu Lek Yuen Shatin, New Territories, Hong Kong, P.R.C. Phone: 85 690 50 Fax: 85 79 4598 Email: tiap@rtpumps.com Italy Rietschle Thomas Italia, S.p.A Via Brodolini, 7 00 Cormano (Milano), Italy Phone: +9 0 64 5 Fax: +9 0 66 50 99 Email: info.it@rtpumps.com New Zealand Rietschle Thomas New Zealand P.O. Box 45 40 Anvil Road, Silverdale Auckland, New Zealand 0 Tel: 64 9 46 070 Fax: 64 9 46 07 Email: tiap@rtpumps.com Sweden Rietschle Thomas Sweden AB Götlundagatan SE-47 Bandhagen, Sweden Phone: 46 8 447 80 Fax: 46 8 447 89 Email: infosweden@rtpumps.com Brazil Rietschle Thomas Brasilien Comérico Ltda. Rua Shigeru Hayashi, 49 CIC 870-640 CURITIBA - PR Brazil Tel: 55 4 47 049 Fax: 55 4 47 090 Email: mschmidt@rtpumps.com Denmark Rietschle Thomas Denmark, A/S TåstruphØj P O BOX 85 400 Holbæk, Denmark Phone: 45 59444050 Fax: 45 59444006 Email: rtpumpsdk@rtpumps.com France Rietschle Thomas France, S.A.S. Zone Industrielle Liesbach 8, rue des Champs 680 Hesingue, France Phone: + 89 70 6 76 Fax: + 89 70 9 0 Email: service.commercial@rietschle.fr Japan Rietschle Thomas Japan 794 Nippa-cho Kohoku-ku Yokohama-shi, Kanagawa -0057 Japan Phone: 8 45 5-090 Fax: 8 45 5-09 Email: tiap@rtpumps.com Korea Rietschle Thomas Korea Room 50, Joong Ang Induspia Building 57-, Sang Dae Won Dong, Joong Won Ku Sung Nam City, Kyung Ki Do Korea 46-7 Tel: 8 740 95 Fax: 8 740 958 Email: tiap@rtpumps.com Netherlands Rietschle Thomas Netherlands B.V. Bloemendalerweg 5 8 KC WEESP, Netherlands Phone: + 94 48686 Fax: + 94 4706 Email: verkoop@rtpumps.com Switzerland/Liechtenstein Rietschle Thomas Switzerland Lindacherstr. CH-54 Birmenstorf AG Switzerland Phone: 4 0 56 0 46 4 Fax: 4 0 56 0 46 6 Email: info@rtpumps.ch Taiwan Rietschle Thomas Taiwan F., No.0, Wugong rd Rd., Wugu Shiang, Taipei County 4889, Taiwan Phone: 886 9955 Fax: 886 9959 Email: tiap@rtpumps.com United Kingdom Rietschle Thomas UK Unit, Alton Business Centre Omega Park, Alton Hants Hampshire GU4 YU United Kingdom Phone: 040 544 84 fax: 040 544 8 E-mail: ukinfo@rtpumps.com Germany Rietschle Thomas Puchheim GmbH Siemensstraße 4 Gewerbegebiet Nord 878 Puchheim Germany Phone: +49 89 80 900 6 Fax: +49 89 80 900 7 Email: mgraham@rtpumps.com ISO900: 000 Registered Company Welch Vacuum Technology products are manufactured at ISO900 registered plants in Sheboygan, WI and Monroe, LA. 6/005 Cat. No. MB-99