MultiFix Central unit

Similar documents
MultiFix Central unit

Portable central unit for several parameters

Dissolved Oxygen Measurement liquisys M COM 223 / 253

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0)

COBRIX3 multibev. Online Beverage Analyzer. ::: Unique Density & Concentration Meters

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Series 5000 Hydrazine Analyzer Model 60002

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Chlorine gas leak detector

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

Concise catalogue Water-Industry

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Product waste disposal - Protection of the environment:

RES-210 (-211, -220, -221) / RES-420

1 4 DIN Dissolved Oxygen Controller

RESISTRON. Replacing RES-102/RES-420. Replacement Instructions. Comparison of RES-102 / RES-420. Dimensions. Temperature indication (actual value)

stationary dose rate measuring systems

Inductive. Range. S410/IND Electrodeless Conductivity Sensors

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Dräger Polytron 8310 IR Detection of flammable gases and vapour

OPTISENS TUR 2000 Technical Datasheet

LIQUIDATOR Electronic Ionization System

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Emerson Blue Easy Set 1H/1C

RPM1600 Series Room Pressure Monitors

WASTEWATER Online UV%Transmission Analyzer

Dräger Polytron 8700 IR Detection of flammable gases and vapors

RS Pro Infrared Temperature Sensor

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

ExStik DO600 USER GUIDE. Dissolved Oxygen Meter. 99 Washington Street Melrose, MA Phone Toll Free

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

THX-DL Data Logger USER & INSTALLATION MANUAL V

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Dissolved Oxygen Measurement liquisys S COM 223 / 253

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

Pioneer-R16 Gas Monitor Operator s Manual

MC 31 Speed Controller Technical User Guide Code no GB

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

Halton SAFE / 7.14 user guide and installation instructions

Operating Manual UV Monitor UVT 18

FIRERAY 5000 range USER GUIDE

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

User Manual. Dryer Controller M720

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Universal Gas Detector

DOL 31 Speed Controller Technical User Guide

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

Dräger Polytron 8100 EC Detection of toxic gases and vapors

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

Toxic Gas Detection. Model F12. Toxic Gas Detection

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

Analog Room Pressure Monitor RPC Series

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

The A-series Eletta Flow Monitor with local indication and analog output

Dräger Polytron 5720 IR Detection of carbon dioxide

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Dryer Controller M720

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Low Temperature Zirconia Oxygen Analyzer

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

SCHMIDT LED Measured Value Display MD Instructions for Use

WIO200 Water In Oil measuring instrument

Beacon 800 Gas Monitor Operator s Manual

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

Color Touch Heating Thermostat WARMTEC WTS

ETO 2 - Controller for ice and snow melting

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

SECTION Fluorescent Dissolved Oxygen Measuring System

Owner s Manual RD432-0 Chemical Controller

Rosemount 3490 Series

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

User's Guide. CO 2 Monitor. Model CO200

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Carbon Monoxide Transmitter

Product Manual SZ1145

Mark 25 Ultrapure Water Conductivity Analyzer

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Greentrol Automation, Inc.

Transcription:

MultiFix Manual MultiFix Central unit 2015-12- 01 C85C5EN16

Contents CONTENTS... 2 GENERAL INFORMATION... 4 SAFETY INFORMATION... 4 DESCRIPTION OF OPERATION... 4 FUNCTIONS FOR MEASUREMENT... 4 UNPACKING... 4 STARTING MULTIFIX... 5 HANDLING AND INTERFACES... 6 DESCRIPTION OF DISPLAY... 6 MAIN MENU... 7 SETTINGS... 7 PREFERENCES... 7 SETUP... 8 Language... 8 Time and date... 8 Temperature units... 9 MEASURING UNITS (CONCENTRATION)... 9 OUTPUTS... 9 4-20 MA OUTPUTS... 10 ACTIVE OR PASSIVE OUTPUT... 10 RELAY OUTPUTS... 11 MAINTENANCE... 11 TROUBLESHOOTING... 11 CONTACT INFORMATION... 12 WARRANTY... 12 TECHNICAL SPECIFICATION, MULTIFIX... 12 APPENDIX 1, OXYDUO (DISSOLVED OXYGEN SENSOR)... 13 DESCRIPTION OF FUNCTION... 14 MEASURING CELLS... 14 CONFIGURATION... 14 MAINTENANCE... 14 Inspection of the sensor... 14 TROUBLESHOOTING... 14 CALIBRATION... 14 Zeroing... 15 Air calibration... 15 SPECIFICATION, OXYDUO... 15 APPENDIX 2, SOLIDO (SUSPENDED SOLIDS SENSOR)... 16 DESCRIPTION OF FUNCTION... 17 SENSOR... 17 CONFIGURATION... 17 MAINTENANCE... 17 Inspection of the sensor... 17 2

TROUBLESHOOTING... 17 CALIBRATION... 18 Calibration with sludge... 18 Lab test... 18 Zeroing... 18 SPECIFICATION, SOLIDO... 19 3

General information It is important to read this manual before starting to use the instrument. If MultiFix is not used as described in the manual, the lifetime of the instrument may be reduced and warranties will cease to apply. Safety information It is important that only authorised and trained staff use the equipment. Be sure to follow local safety procedures when taking samples beside and in basins. Within the EU, it is prohibited to dispose of electrical and electronic waste in the rubbish. Electrical and electronic waste may contain hazardous substances, and must be sorted and left for recycling. The products concerned are marked with a crossed- out dustbin. It is important for everyone to play their part in recovering electrical and electronic waste. If this waste is not recovered in accordance with the regulations (EU Directive 2002/96/EC), both the environment and human health may be endangered. Description of operation The MultiFix central unit can be used with several different types of Cerlic sensors in the Multi series. Up to two sensors can be connected to the central unit via M12 contacts on the bottom of the housing. There are four 4-20 ma signal outputs and two alarm relays for connection to an external control system. Functions for measurement Up to two sensors included in the Multi series can be connected to a MultiFix central unit. Each sensor presents the measured value and temperature on the display on the central unit. Unpacking Open the instrument housing and check that no damage has occurred during transport. The instrument housing should contain the following parts, and the manual; see Figure 1 Fig. 1 4

Starting MultiFix First switch on the central unit and check that it is working properly. Also check that the analogue outputs are connected correctly. At start- up without any sensors connected, the following display appears; see Figure 2. Fig. 2 Connect one sensor at a time to facilitate configuration and minimize the risk of error. When a sensor is connected, the MultiFix unit asks what position the sensor should be installed in. If a sensor has already been installed in this position, MultiFix asks whether the previous sensor should be replaced; see Fig. 3. Fig. 3 The configuration of the sensors is automatically saved in the central unit. After a power outage, the unit restarts and starts measuring again as soon as the power supply has been restored. The measurements are shown as text on the display. The appearance of the display may vary according to the parameters being measured. 5

Handling and interfaces The icons below represent the buttons on the keypad and describe their functions. Opens the menu structure and confirms a selection from a menu. Completes the present menu selection without changing any value, or goes back a step in the menu hierarchy (escape function). Navigates up the menu hierarchy, or increases the value of the selected entry in a menu. Navigates down the menu hierarchy, or decreases the value of the selected entry in a menu. Graph button, toggles between measuring units. Turns on backlighting of the display. The light stays on for two minutes, but the time can be adjusted under Preferences Light time. Description of display In the standard version, at start- up, the display looks like the Figure below. It shows the type of sensor, the measuring unit and the temperature on the left side of the display. The current measurement is shown on the right, and the signals from the four ma outputs can be read at the bottom. If either of the two alarm contacts is in an alarm state, this is shown on the display as R1 or R2 at the bottom right. General information such as time and date is always shown at the top left of the screen. The information shown on the display will vary according to the sensor that is connected. The screenshot below is for an Oxyduo dissolved oxygen sensor. Date, time High alarm Type of sensor Measurement Temperature Signals from the four ma outputs Relay output 2 in alarm state 6

Main menu Press to open the main menu. See Fig. 5. Use or to reach the right sub- menu and open this with. Fig. 5 Settings Under SETTINGS in the menu (Fig. 5), you can configure alarm limits for the two relays in the central unit. In the menu, the alarm limits are called Threshold 1 and Threshold 2. The relays are independent of each other and can be used as Min and Max alarms, for example. The settings depend on the sensor that is connected. The screenshot below shows an example of a lower alarm limit and an upper alarm limit for a sensor. (Fig. 6) These settings are needed for controlling the relays. Fig. 6 Preferences In the Preferences menu (Fig. 7) you can select the light time in minutes for backlighting of the display with a single keystroke. Fig. 7 7

Setup The Setup menu (Fig. 8) is used to select the language, date format, temperature units and units for displaying the measurement. Fig. 8 Language The following languages are installed on the instrument: Swedish, English, German and French. To change the language, proceed as follows: Press to open the menu. Step down with and select SETUP using. Select Language and confirm with. Step up in the menu using or down using until your desired language is shown and confirm with until it closes.. Then back out of the menu with Time and date To set the time and date: Press to open the menu, Fig. 12. Step down in the menu with and select SETUP using. Step down with and select Time and Date. Confirm with. Step up with or down with until the right time and date format is selected. Step up with or down with and enter today's date and the current time. Confirm and step further through the menu with. If all settings are complete, back out of the menu with until the menu closes. Fig. 12 8

Temperature units The following temperature units are available: C, F, or K. Press to open the menu. Step down with and select Setup using. Step down in the menu with. Select Temp. unit and confirm your selection with. Step up with or down with and select the desired unit (C, F, K). Confirm with. If all settings are complete, back out of the menu with until the menu closes. Measuring units (concentration) The following units are available to display the measurements: g/l, mg/l, %, and ppm. Press to open the menu. Step down with and select Setup using. Step down in the menu with and select Conc. unit. Confirm with. Step up with or down with and select the desired unit (g/l, mg/l, %, ppm). Confirm with. If all settings are complete, back out of the menu with until the menu closes. Outputs The output menu can be used to configure connected sensors. There are four 4-20 ma signal outputs available in total. Normally, two outputs are used per sensor, one for the measurement and one for the temperature. (Fig. 9). Fig. 9 9

4-20 ma outputs When ma output 1 is selected, the following display text is shown Source sensor. Select the type of sensor that should be linked to this analogue signal output. Parameter is used to select whether the output signal should relate to the measurement or the temperature. Under Scaling 4 ma and Scaling 20 ma you can set the Min and Max values for the measuring range in correspondence to the output signal. Outputs 2-4 are configured in the same way. The values for Calibration 4 ma and Calibration 20 ma must not be changed. Fig. 10 Active or passive output Above the terminal block for the output signals is a small jumper that can be switched between the active and passive signal outputs. Fig. 15 10

Relay outputs The two relay outputs can be configured for Max or Min alarms for one sensor or for several sensors at the same time. Min and Max values are linked to the alarm limits (thresholds) set for the different sensors. The relays (with changeover contacts) open or close (depending on the connection) when the measurement exceeds or drops below an alarm limit. (Fig. 11) Fig. 11 Maintenance The instrument is designed for minimum maintenance. The instrument housing is IP54 (NEMA3). The sensor cable is specially made in PUR with a strong shield and extra strands for long life. The sensor and the cable clamps are of the MatchClamp type to guarantee no leaky contacts or distorted cables. Troubleshooting Screen on the central unit is blank - Check the fuses in and to the central unit and that the unit has a power supply. No measurement or sensor found on the central unit - Check that the sensors are connected correctly by the M12 contact. If the instrument shows divergent values, it should be re- calibrated. See section on Calibration under the relevant sensor for instructions. If an error occurs that cannot be rectified by troubleshooting or calibration, contact Cerlic Controls for further information. Contact Cerlic Controls AB before returning the instrument and fill in the service form on our website (www.cerlic.se) to simplify processing. 11

Contact information The correct return address can always be obtained from the Cerlic website. www.cerlic.se Europe Cerlic Controls AB Mälarvägen 3, 141 71 SEGELTORP Tel.: 08-50 169 400, E- mail: info@cerlic.com Postal address: P.O. Box 5084, 141 05 KUNGENS KURVA Internet: www.cerlic.com US & Canada Cerlic Environmental Controls, Inc. 200 Burdette Road Atlanta, GA 30327 Tel.: 404-256- 3097 Warranty All instruments from Cerlic Controls AB are thoroughly checked and tested before delivery. Cerlic offers a warranty and will repair the instrument if it is found that the problem is traceable to our production or equipment. The warranty applies within a specified period Technical specification, MultiFix Number of sensor connections Measuring units Display Backlighting Languages ma 4-20 outputs 4 RS232 outputs 1 Relay outputs 2 Supply voltage Material, housing Temperature range Keypad Weight, Multifix central unit Weight of sensor Dimensions, Multifix central unit Two g/l, mg/l, %, ppm Graphical, 128 x 64 pixels, LCD Yes, and time adjustment for summertime Swedish, English, German, French 110/220/240 VAC 50-60 Hz 12-24 VDC optional Aluminium - 10 - +50 C 6 membrane keys 1.5 kg 0.5 kg each 200x110x60 mm (W x H x D) IP class IP54 (NEMA 3) 12

Appendix 1, Oxyduo (Dissolved Oxygen Sensor) Oxyduo Dissolved Oxygen Sensor for liquids 13

Description of function Oxyduo has been developed to constantly measure the oxygen level in the treatment plant like aeration basins, waterworks, groundwater, lakes etc. The measurement is shown in text form on the central unit display and presented externally via a 4-20 ma output signal. Measuring cells The sensor is fitted with an electro- chemical Clark electrode. The sensor body contains electronics and mechanical parts that must not be subjected to impact. In the event of damage to the sensor body, water may penetrate and damage the optics/electronics. There is no way of replacing components; see Maintenance for more information. Configuration See section describing the MultiFix central unit. Maintenance The Oxyduo is designed for minimum maintenance. All metal parts are acid- resistant stainless steel (SS 2343/SS316). The sensor cable is specially made in PUR with a strong shield and extra strands for long life. The sensor and the cable clamps are of the MatchClamp type to guarantee a watertight sensor. Inspection of the sensor The sensor head should be cleaned if a deposit has accumulated on the cell. If not, it could affect the measurements. Use water and a soft sponge. To verify that the measuring cell is working properly, an air calibration can be performed. See section on Calibration. Troubleshooting In the event of malfunctions that cannot be fixed by calibration, contact Cerlic for further information. Contact Cerlic Controls AB before returning the instrument and fill in the service form on our website (www.cerlic.se) to simplify processing. Calibration The electro- chemical measuring cell (Clark electrode) is supplied fitted in the sensor. Two point calibration (Zero & air) has been performed in factory. The procedure, described below, can be used to check the functioning of the measuring cell. Fig. 13 14

Zeroing Disconnect the electrode from the sensor. Press to open the menu and step down using. Select Calibration using. Step down with and select Zero. Confirm with. Wait until stable values are shown and confirm with. When the zeroing is complete, back out of the menu with all the way to the main menu and the measurement display. Air calibration Press to open the menu and step down using. Select Calibration using. Step down with and select Sample. Confirm with. Hold the sensor vertical in the air (best result in high humidity air) and wait until the temperature reading is stable. Confirm with complete, back out of the menu with the measurement display.. When air calibration is all the way to the main menu and Specification, Oxyduo Parameter Dissolved oxygen concentration Measuring principle Electro- chemical, Clark Measuring range 0 to 20 mg/l (ppm) Accuracy 1% FS (full scale) Repeatability < 2% of measured value Type of measurement Continuous Measuring units g/l, mg/l, ppm Max. depth 10m Temperature range - sample 0 +50 C Sensor body Stainless steel Cable PUR, shielded Cable clamp MatchClamp Weight, sensor 450 g Dimensions, sensor body 145mm x 32 mm Ø Cable length 4 m, 8 m, or 12 m IP class, sensor body IP68 (NEMA 7) 15

Appendix 2, Solido (Suspended Solids Sensor) Solido Suspended Solids Sensor 16

Description of function Solido is an optical suspended solids sensor developed to measure the suspended solid in basins and tanks in purification plants and outdoor waterworks with sludge concentrations up to 35,000 mg/l depending on the type of sludge. Sensor The sensor body contains optics and electronics that must not be subjected to mechanical impact. In the event of damage to the sensor body, water may penetrate and damage the optics/electronics. See section on Maintenance for more information. Configuration See section describing the MultiFix central unit. Maintenance Solido is designed for minimum maintenance. All metal parts are acid- resistant stainless steel (SS 2343/SS316). The sensor cable is specially made in PUR with a strong shield and extra strands for long life. The sensor and the cable clamps are of the MatchClamp type to guarantee a watertight sensor. Inspection of the sensor The sensor should be cleaned if a deposit has accumulated on the lenses in the measuring gap. To check whether cleaning is needed, the sensor should be dipped in clean de- aerated water. The measurement on the display should not differ by more than ±10mg/l from zero. If the measured result differ by more, the sensor should be cleaned. Strong accumulated dirt: Clean by dipping the sensor into a weak acid solution, about 3 % hydrochloric acid in water, for 10-15 minutes. (Just water and a sponge will not normally be enough). After cleaning, perform a further check in clean de- aerated water. In case of lighter dirt, it may be sufficient to clean the sensor carefully with a sponge and water with some dish soap. Rinse the sensor with clean water. Make sure that the lenses are not scratched. If the measurement still differs from zero, a zero calibration should be performed in the clean de- aerated water. See section on Calibration. Troubleshooting In the event of malfunctions that cannot be fixed by calibration, contact Cerlic for further information. Contact Cerlic Controls AB before returning the instrument and fill in the service form on our website (www.cerlic.se) to simplify processing. 17

Calibration The sensor is factory- calibrated before delivery. After commissioning, we recommend calibrating the sensor once more, but this time in the relevant sludge. Calibration with sludge Press to open the menu and step down using. Select Calibration using. Step down with and select Sample. Dip the sensor in a sludge sample and stir the sample gently with the sensor to prevent sedimentation, confirm with. When the calibration is complete, back out of the menu with all the way to the main menu and the measurement display. Fig. 14 Lab test Run a lab analysis on the sludge sample and determine the correct sludge concentration. Press to open the menu and step down using. Then select Calibration with. Step down with and select Lab. test. Confirm with. Change the old value to the new one, obtained from the lab analysis, using or. Confirm with. Press all the way to the main menu and the measurement display. Zeroing The zeroing carried out at the factory does not need to be repeated and normally should not be. If the sensor does not show zero in completely clean de- aerated water despite cleaning in a weak acid solution, zeroing can be carried out according to the procedure below. Press to open the menu and step down using. Select Calibration using. Step down with and select Zero. Confirm with. Dip the sensor into clean water and confirm with back out of the menu with measurement display.. When the zeroing is complete, all the way to the main menu and the 18

. Specification, Solido Parameter Measuring principle Wavelength Measuring range Accuracy, sludge Repeatability Type of measurement Measuring units Max. depth Temperature range - sample Sensor body Cable Cable clamp Weight, sensor Dimensions, sensor body Cable length Suspended Solids Optical, transmission NIR 850 nm Up to 35,000 mg/l (ppm) depending on sludge type 1% FS (full scale) < 2% of measured value Continuous g/l, mg/l, %, ppm 19m 0 +50 C Stainless steel, BK7 glass PUR, shielded MatchClamp 450g 145mm x 32 mm Ø 4 m, 8 m, 12 m, 20 m IP class, sensor body IP68 (NEMA 7) 19