Branching and Connection Box AAB. Operating manual AAB EN11. GTE Industrieelektronik GmbH

Similar documents
GSME Tester GTL-2. Operating manual GTL EN10. GTE Industrieelektronik GmbH

HOTSPOT-1000 HOTSPOT Thermographic Surface Temperature Detector. Installation - Operation - Maintenance EN11

GSME. Industrial-suited fire gas detectors with multiple semiconductor gas-sensors, integrated signal evaluation and M-Bus interface

HOTSPOT

Industrial Fire Detection

Industrial fire alarm systems

Gas Sensor Fire Detector GSME-Ex

HOTSPOT. Industrial-suited parametrizable Infrared heat detectors with integrated signal processing and evaluation

Test Unit GTL 100 for Fire Detectors

Original operating instructions Safety switch with guard locking AC901S AC902S

Snifter ATEX22 VERSION. User Manual. Distributor

FDBZ290 Air sampling smoke detection kit Technical Manual

Remote alarm indicator and test combination MK2430

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

Operating Manual MS220DA

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

OPTISENS TUR 2000 Technical Datasheet

AM1 alarm module. RESOL AM1 alarm module * * Mounting Connection Function. Manual

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

3-way switching valve

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Katherm NE - Natural convection with electric heating element 2.45

Mounting Instructions Adapter for ventilation duct BWP-143A-SS, Stainless Steel version

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

BL 200 Strobes. Page F.01U A1.en/ 6/2/2004 ST / PMF1 / zab

FDCL221 Line separator

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Fire PROtec. Manual for automatic Fire Curtains. copyright by SIMON RWA Systeme GmbH Passau

Explosion Protection Enclosure with integrated measuring system

Building Technologies SIGMASYS M Multifunctional danger alarm control and indicating panel

Operating Manual MS220KA and MSR220KA

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

Fire & Security Products. Cerberus D100 Multifunctional process control for company security

FDBZ290 Air sampling smoke detection kit

Installation and user manual for the BiWire / Conventional Repeater Panel

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Operating Manual RCM420

Anti-condensation Heater

Installation manual plugs and connectors QUICK-CONNECT (63 A)

Installation Instruction. Fire Alarm Control Panel IQ8Control C/M GB0 G G Technical changes reserved!

Operating Instructions

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

READ AND SAVE THESE INSTRUCTIONS

Installation and operating instructions. DK energy storage and DK energy buffer

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

BES M30EP-PFC12F-S04G-D12 BES Q40ZU-PFC15B-S04G-D12 BES Q40ZU-PFC20F-S04G-D12 Inductive Safety Sensors User's Manual

INSTRUCTION MANUAL (ATEX / IECEx)

UV Flame Supervision System

Installer manual AG-WL10

Flameproof Manual Call Points

Engineering Guideline. pac- Carriers Type Universal

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

TTV 4500 / TTV 4500 HP / TTV 7000

SINAMICS G130. Cabinet design and EMC. Operating instructions 03/2011 SINAMICS

PROTECT SRB 200EXi-1A

OOH740, OOHC740 Automatic fire detectors

SINAMICS G130. Cabinet design and EMC. Operating Instructions 05/2010 SINAMICS

Control and Indicating Equipment

VIESMANN. Installation instructions VITODENS 200-W. for contractors

1.7. Insulation fault evaluators EDS460/490 EDS461/491

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Translation of the assembly instructions with operating instructions and technical appendix

GMA Panels with double busbar

TRENCH HEATING LIMITED

Overload Relay EMT6 Overload monitoring system for machines operating in the EEx e area

Procedure for the Approval of New Fire Detection and Alarm Technologies

MBZ300. Emergency power control unit. GB Installation instructions MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 PME PME. Reset.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

FDBZ290 Air sampling smoke detection kit

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

Table of Content LT 5165-UL

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Installation, operating and servicing instructions

Operating instructions Electric agitator RE80Ex. T-Dok-520-GB-Rev.5 Article no Translation of the original operating instructions

Insulation fault evaluator EDS460-DG

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

ATM Lighting sp. z o.o

FC2020 Fire control panel

1592P01. for liquids in piping DN

ISIS SAFETY SYSTEM Installation guide

Manual call point SM 210 LSN RW

* * EC1. Variable controller for circulation systems Mounting and operation manual

Transcription:

AAB 430-2410-001 EN11 EN Operating manual Branching and Connection Box AAB GTE Industrieelektronik GmbH Helmholtzstr. 21, 38-40 D-41747 Viersen, GERMANY info@gte.de +49(0)2162 / 3703-0 www.gte.de

Branching and Connection Box AAB Document version: 430-2410-001 EN11 Translation Manufacturer: GTE Industrieelektronik GmbH Helmholtzstr. 21, 38-40 41747 Viersen GERMANY Support hotline: +49 (0)2162 / 3703-29 E-Mail: service@adicos.de 2016 GTE Industrieelektronik GmbH This document and all figures contained may not be copied, changed, or distributed without explicit approval by the manufacturer! Subject to technical changes!

ABSTRACT Abstract The Advanced Discovery System (in short: ADICOS) is used for early detection of fire scenarios in the industrial environment. It comprises different, independent detector units that enable interference-resistant fulfillment of the detection objective defined during planning via suitable layout and parameterization. The detector units are connected using the ADICOS M-bus to a central unit, which enables voltage supply and parameterization of every individual detector, and which stores all sensor data for statistical analyses. ADICOS branching and connection boxes are used as a wiring accessory. 430-2410-001 EN11 I

CONTENTS Contents 1 About this manual... 3 1.1 Objective... 3 1.2 Explanation of symbols... 3 1.3 Abbreviations.... 4 1.4 Storing the manual... 4 2 Safety instructions.... 5 2.1 Intended use... 5 2.2 Standards and regulations... 5 2.3 Personnel qualification... 6 2.4 Modification... 6 3 Scope of delivery....6 4 Structure... 7 4.1 Overview... 7 4.2 Connections... 8 4.3 Cable glands.... 10 4.4 Display elements.... 10 5 Installation... 11 5.1 Selecting the mounting location... 11 5.2 Opening the enclosure cover... 11 5.3 Wall mounting... 12 5.4 Wiring... 13 6 Commissioning... 20 7 Operation... 20 8 Fault...20 9 Maintenance.... 21 9.1 Replacing the fuse.... 21 10 Disposal....21 11 Technical data... 22 II 430-2410-001 EN11

About this manual 1 About this manual 1.1 Objective This manual describes the proper assembly, wiring, commissioning, and operation of ADICOS branching and connection boxes. After commissioning, they are used as reference work in the case of faults. It is exclusively addressed to knowledgeable specialist personnel ( Chap. 2, Safety instructions). 1.2 Explanation of symbols This manual features a continuous structure for best possible comprehension. The following labels are used. Action objectives Action objectives describe the result to be achieved by the subsequent instructions. Action objectives are presented in bolt font. Action instructions Action instructions describe the activities to be performed in order to achieve the action objective previously mentioned. Action instructions are presented as follows. Individual action instruction 1 First of several sequential action instructions 2 Second of several sequential action instructions 3 etc. Intermediate states In case of describable intermediate states or results, which are the result of action steps (e.g. displays, internal function steps, etc.), they are presented as follows. ZZ Intermediate state Warning signs This manual uses the following information types. NOTE! This information type provides information directly important for further system operation. 430-2410-001 EN11 3

About this manual WARNING! This information type signals a danger that can lead to fatal or severe injuries. DANGER! This information type signals a danger that directly leads to fatal or severe injuries. 1.3 Abbreviations This manual uses the following abbreviations. Abbr. Meaning ADICOS Advanced Discovery System AAB ADICOS Branching and Connection Box BMZ ADICOS Central Fire Alarm Panel BMZ-30 M-BM ADICOS M-Busmaster NT ADICOS Power Supply NT V40-A3 FDnet Field Device Network (fire alarm bus of SIEMENS fire alarm systems) LSN Local Security Network (fire alarm bus of BOSCH fire alarm systems) FAS Fire Alarm System 1.4 Storing the manual Store this manual easily reachable and in direct vicinity of the system to enable use as needed. 4 430-2410-001 EN11

Safety instructions 2 Safety instructions ADICOS branching and connection boxes (in short: AAB) ensure operational safety assuming proper installation, commissioning, operation, and maintenance. For this purpose, it is absolutely required to completely read, understand, and follow this manual and the safety instructions contained. WARNING! Installation and operating errors can lead to fatal and severe injuries and damage to the industrial system. Read and follow this manual carefully! 2.1 Intended use s are distribution boxes for the electrical connection of ADICOS detectors with the fire alarm cable of ADICOS systems. They additionally enable feeding-in an external voltage supply using the ADICOS power supply NT V40-A3. In this context, the operating parameters described in Chap. 11,»Technical data«must be met. Any deviating use requires prior consultation with the manufacturer. Compliance with this manual as well as all applicable country-specific provisions is also part of the intended use. 2.2 Standards and regulations The safety and accident prevention regulations applicable for the specific application must be observed during AAB installation, commissioning, maintenance, and test. The following standards and directives are of particular importance when handling fire alarm systems: Regulation VDE 0100 VDE 0800 VDE 0833 VDE 0845 VdS 2095 DIN 14675 Description Erection Of Power Installations With Rated Voltages Below 100 Telecommunications - General Concepts - Requirements And Tests For The Safety Of Facilities And Apparatus Alarm Systems for Fire Protection Of Telecommunication Systems Against Lighting, Electrostatic Discharges and Overvoltages From Electric Power Installations; Measures Against Overvoltages Guidelines For Automatic Fire Detection And Fire Alarm Systems - Planning And Installation Fire Detection And Fire Alarm Systems - Design And Operation 430-2410-001 EN11 5

Safety instructions 2.3 Personnel qualification Any work on ADICOS systems may only be performed by qualified personnel. Persons, who can perform work on electrical systems and recognize possible dangers based on their professional education, knowledge, and experience as well as knowledge of the applicable provisions, are considered qualified personnel. WARNING! Installation, commissioning, and maintenance may only be performed by respectively trained personnel 2.4 Modification Any form of unauthorized modifications or extensions are expressively prohibited! In case of doubt, contact the manufacturer. 3 Scope of delivery The following components are included in the scope of delivery of the : Quantity Description 1 with 3 cable glands and 2 dummy cable glands 2 M20* cable glands * Are located inside the enclosure at the time of delivery 6 430-2410-001 EN11

Structure 4 Structure 4.1 Overview No. Description Enclosure screws (4x) Enclosure cover Enclosure base AAB circuit board with connection terminals Blind cable glands (2x) Cable glands (3x) 430-2410-001 EN11 7

Structure 4.2 Connections 4.2.1 Connection terminals LOOP IN Input for fire alarm loop +24V Voltage supply (+) 0V Voltage supply ( ) X7 (fault) X6out (alarm) X6in (alarm) MBus A MBus B Normally closed contact, fault Normally open contact, alarm Normally open contact, alarm External fire alarm in SIEMENS FDnet-A ( ) BOSCH LSN b1 in External fire alarm in SIEMENS FDnet + BOSCH LSN a in ADICOS M-Bus ADICOS M-Bus 8 430-2410-001 EN11

Structure LOOP OUT Output for fire alarm loop +24V Voltage supply (+) 0V Voltage supply ( ) X7 (fault) X6out (alarm) X6in (alarm) MBus A MBus B Normally closed contact, fault Normally open contact, alarm Normally open contact, alarm External fire alarm out SIEMENS FDnet-B ( ) BOSCH LSN b2 out External fire alarm out SIEMENS FDnet + BOSCH LSN a out ADICOS M-Bus ADICOS M-Bus GSME Detector connection +24V Voltage supply DC (red) 0V MBus A MBus B B1 A1 B2 A2 X6e X7e X6a X7a Voltage supply (black) ADICOS M-Bus (blue/red) ADICOS M-Bus (gray/pink) Coupling module B - in (pink) Coupling module A - in (blue) Coupling module B - out (purple) Coupling module A - out (gray) Normally open contact, alarm (yellow) Normally closed contact, fault (green) Normally open contact, alarm (white) Normally closed contact, fault (brown) GSME Power supply Coupling of external power supply 0V External power supply +24V External power supply DC PE Protective conductor PE Protective conductor 430-2410-001 EN11 9

vv Structure 4.3 Cable glands 1 2 3 4 5 The following assignment is an example only and varies by system configuration. No. Description ADICOS primary line (ADICOS M-Bus / power supply / limit value- detection line) ADICOS primary line (ADICOS M-Bus / power supply / limit value- detection line) FAS loop External power supply (optional) (External fire alarm LOOP) (optional) FAS loop (External fire alarm LOOP) (optional) ADICOS connection cable for ADICOS detector 4.4 Display elements Power LED The power LED is located on the upper edge of the AAB board, centered between the connection terminals for the fire alarm loop. It lights up green, if power supply is connected to the. 10 430-2410-001 EN11

Installation 5 Installation 5.1 Selecting the mounting location The following aspects must be considered when selecting the installation location. The installation floor must be sufficiently firm and as vibration-free as possible. The installation environment must meet the climate conditions specified in the technical data. Install the in close proximity to the connected detector and well accessibly. 5.2 Opening the enclosure cover NOTE! The protection class of the enclosure specified in the technical data is only given with the closed enclosure cover and cable glands. Close enclosure cover and cable glands prior to commissioning! 1 Loosen the enclosure screws using a sufficiently large slotted screwdriver (4x) 2 Lift off the enclosure cover 430-2410-001 EN11 11

Installation 5.3 Wall mounting Mounting the to a wall 95 1 Depending on the underground, drill mounting holes for sufficiently dimensioned screws and/or wall plugs (4x) (see drilling plan) 2 Press in wall plugs 3 Open enclosure cover 4 Insert sufficiently dimensioned mounting screws through the tightening channels of the enclosure screws in the enclosure base so that the screws protrude from the rear side of the enclosure (4x) 5 Place the enclosure base with the screws onto the mounting holes with wall plugs 6 Tighten the screws (4x) 7 If wiring is not completed immediately, close the enclosure cover 95 12 430-2410-001 EN11

Installation 5.4 Wiring WARNING! Improper installation of the s can lead to faults and failures of the detector system. Wiring may only be performed by specialist personnel! ( Chap. 2.3, Personnel qualification) Use ADICOS connection cables for detector wiring only! Only use suitable fire alarm cables for the ADICOS primary line and FSA loop! NOTE! The protection class of the specified in the technical data is only given if all cables are routed into the enclosure through the cable glands and the glands are then securely tightened. A A The wiring plan of the varies depending on system configuration and topology. The following procedure applies for all wiring variants. Wiring the 1 Open enclosure cover 2 Open cable glands 3 Route cables through the cable glands into the enclosure according to Chap. 4.3 4 Connect the wires to the connection terminals according the wiring diagram 5 Close cable glands 6 Close enclosure cover 430-2410-001 EN11 13

Installation In the case of wiring variants with more than 3 cables: Installing additional cable glands 1 Open enclosure cover 2 Take the loose additional cable glands from the enclosure 3 Unscrew the blind plugs and ( Chap. 4.3) using the large slotted screwdriver 4 Screw in the additional glands to the M20 threads using a 25 mm torque wrench (6.0 Nm tightening torque) 5.4.1 ADICOS BMZ / M-BM (voltage supply via M-Bus) ADICOS BMZ-30 M-Busmaster M-Bus M-Bus + (24 V) (24 V) X7 (Stoer) X6aus (Al) X6ein (Al) ADICOS-AAB X7 (Stoer) X6aus (Al) X6ein (Al) next ADICOS-AAB PE PE red black yellow green white brown pink blue violet grey blue/red grey/pink B1 A1 B2 A2 X6e X7e X6a X7a ADICOS connection cable / detector 14 430-2410-001 EN11

Installation 5.4.2 ADICOS BMZ / M-BM and external power supply ADICOS BMZ-30 M-Busmaster + (24 V) (24 V) M-Bus M-Bus ADICOS ext. power supply NT V40-A3 X7 (Stoer) X6aus (Al) X6ein (Al) PE PE ADICOS-AAB X7 (Stoer) X6aus (Al) X6ein (Al) next ADICOS-AAB +4 red black yellow green white brown pink blue violet grey blue/red grey/pink B1 A1 B2 A2 X6e X7e X6a X7a ADICOS connection cable / detector 430-2410-001 EN11 15

Installation 5.4.3 Limit value detection lines "Fault" and "Alarm" Non-ADICOS fire alarm panel Störung Alarm 1 Alarm 2 X7 (Stoer) X6aus (Al) X6ein (Al) ADICOS-AAB X7 (Stoer) X6aus (Al) X6ein (Al) next ADICOS-AAB PE PE B1 A1 B2 A2 X6e X7e X6a X7a At the end of the line: 3k3 Terminating resistor wire break detection red black yellow green white brown pink blue violet grey blue/red grey/pink ADICOS connection cable / detector 16 430-2410-001 EN11

Installation 5.4.4 Fire alarm LOOP with LSN / FDnet (internal coupling module) NOTE! For integration in BOSCH or SIEMENS fire alarm systems, ADICOS detectors must be equipped with a coupling module by the manufacturer! FDnet/LSN fire alarm panel X7 (Stoer) X6aus (Al) X6ein (Al) ADICOS-AAB X7 (Stoer) X6aus (Al) X6ein (Al) next ADICOS-AAB PE PE red black yellow green white brown pink blue violet grey blue/red grey/pink B1 A1 B2 A2 X6e X7e X6a X7a ADICOS connection cable / detector * Detector with integrated FDnet- or LSN-Module 430-2410-001 EN11 17

Installation 5.4.5 Fire alarm LOOP with other bus (external coupling module) NOTE! For integration in other Non-ADICOS fire alarm systems suitable external coupling modules are required. Non-ADICOS fire alarm bus External connection module Störung 1 Störung 2 Alarm 1 Alarm 2 next ADICOS-AAB X7 (Stoer) X6aus (Al) X6ein (Al) PE PE ADICOS-AAB X7 (Stoer) X6aus (Al) X6ein (Al) B1 A1 B2 A2 X6e X7e X6a X7a red black yellow green white brown pink blue violet grey blue/red grey/pink ADICOS connection cable / detector 18 430-2410-001 EN11

Installation 5.4.6 Primary cable shielding Primary cable X7 (Stoer) X6aus (Al) X6ein (Al) ADICOS-AAB X7 (Stoer) X6aus (Al) X6ein (Al) Primary cable PE PE B1 A1 B2 A2 X6e X7e X6a X7a 430-2410-001 EN11 19

Commissioning 6 Commissioning WARNING! The Advanced Discovery System works with electrical current, which can lead to system damage in the case of improper installation. Prior to system commissioning, make sure that all ADICOS components are properly mounted and wired! Commissioning may only be performed by specialist personnel! NOTE! The ADICOS-AAB is a passive component. Separate commissioning is not required. ZZ ADICOS system commissioning is to be performed according to the instructions of the central unit (ADICOS BMZ-30 / M-Busmaster) used. The green power LED lights up, when the ADICOS system is switched on ( Chap. 4.4) 7 Operation NOTE! The ADICOS-AAB is a passive component. Its operating state depends on the superordinate central unit. The green power LED ( Chap. 4.4) lights up during operation. 8 Fault If the green power LED does not light up, although the system is switched on: Check wiring ( Chap. 5.4) Check fuse and replace as needed ( Chap. 9.1) 20 430-2410-001 EN11

Maintenance 9 Maintenance In genereal the does not require special maintenance. 9.1 Replacing the fuse The features an internal fuse to prevent system destruction and/or ignition caused by too high currents in the case of electrical short circuits. The fuse is located in the upper left area of the circuit board. Replacing the fuse 1 Disconnect the ADICOS system from the mains 2 Open enclosure cover 3 Pull fuse vertically from bracket 4 Insert new fuse (4A, slow-blowing) into the bracket 5 Close enclosure cover 6 Switch on ADICOS system 4AT Loop 10 Disposal Return the product to the manufacturer after the end of the useful life. The manufacturer ensures environmental-friendly disposal of all components. 430-2410-001 EN11 21

Technical data 11 Technical data General information Dimensions: mm 110 x 110 x 60 (W x H x D) Weight: kg 0.38 Enclosure: Polystyrene (corrosion-resistant) Installation: Surface-mounted Cable gland tightening torque: Nm 6.0 Electrical properties Voltage range: V 20... 40 Max. power loss (LED): mw 330 Internal fuse: A (slow-blowing) 4 Max. cable cross-section: mm² 2.5 Environmental conditions Temperature range: C -10... +50 Humidity range: % 0... 95 (non-condensing) Installation environment: Vibration-free Protection class: IP 65 22 430-2410-001 EN11