Rocket Quick Guide. Rocket PSU Portable Suction Unit

Similar documents
OPERATORS GUIDE Rocket R54569 PSU

SEPTIC FLUID ASPIRATOR MEDAP-VENTA SP 26 N MEDAP-VENTA SP 26 A

Thorametrix TM Chest Drainage Systems

Read Only Document Not For Distribution

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

Physician s order will specify the level of underwater seal, typically -10 to 20 centimetres (cm) and will identify if suction is to be applied.

Suction Pump F-30.xx

The new mains-operated ATMOS respiratory tract suction devices in the reliable 26 l and 16 l class

VENTURI Compact 300 NPWT Systems Choice of Therapy Modes Advanced Predictive Low Vacuum Alarm

Clinician Information

Technical Datasheet. Suction Controllers, Flow Meters & Accessories

THORAMETRIX. Chest Drainage Program

Thoracic drainage. Helping improve patient outcomes

MODEL 7000 SUCTION UNIT

Description of the CADD-Prizm VIP Pump

Alaris Syringe Module v9

Special Requirements For Health Care Facilities

Thoracic drainage upgrade:

HANDS-ON MODULE 5. CLEANING FLOW-i V3.0

Administration of AMBISOME Using the GemStar Pump

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

FOR VETERINARY USE ONLY

HOMEPUMP ECLIPSE* Ambulatory Infusion System PATIENT INFORMATION

VARIABLE RATE INFUSION PUMP

1. What does the 3T Heater-Cooler Vacuum & Sealing Upgrade ( 3T V&S Upgrade ) consist of?

STANDARD OPERATING PROCEDURES

Cleaning the internal optics surfaces

VIVA ace Quick Operation Guide

Section. 3: CADD Pump. Updated: June 20, Section Author(s): sstafford & jhval

Alaris Syringe Module v9

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

Post-operative wound drainage High-vacuum drainage Low-vacuum drainage Gravity drainage

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

WARNING: Product view. Cleaning fluid. Carry Handle. Power Button Formula & Clean Water Tank. Dirty Water Tank. Power Cord. Quick Release Cord Wrap

Hemovac Wound Drainage Family. The Time-Tested System for Reliable Wound Drainage and Auto-Transfusion

ASPIRE Laboratory Aspirator

Instructions for use Vacuum regulation valve with water trap

EkoSonic Control Unit Instructions for Use

SUCTION UNIT SUCTION UNIT

Autoclaves. Steam Autoclaves

Cl inician Training Packet

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Thopaz+ Quick Reference Guide. Precious life Progressive care

Basic suction pump - Technical Information

air conditioner/dehumidifier 9000btu/hr

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

PREASSEMBLED SURGICAL WASH SET FOR DIDECO ELECTA

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

Connectors. Right Angled Y-Connectors, swivelling autoclavable up to 134 C, Material: PSU

Thank you for choosing the Motif Duo Double Electric Breast Pump. Motif Duo Operation Manual

CAL. YM22 ANALOGUE ALARM

T-Series Air Conditioner T53 Model

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

T-Series Air Conditioner T20 Model

kéìíê~=iqd=qìåöëíéå=dêáåçéê= lééê~íáçåë=j~åì~ä=

T-Series Air Conditioner T15 Model

Powerful universal suction devices for gynaecology and obstetrics. ATMOS S 351 Natal ATMOS C 451

BARD WOUND DRAINAGE. Products to meet your different procedural needs CLOSED WOUND SUCTION GRAVITY DRAINS SUMP DRAINS

Designed in the UK. Rapide Ultimate. User Guide Vax Rapide Ultimate

Home Choice cycler for Peritoneal Dialysis: Set up, Disconnect, & Disposal Updated 2015

Standard Operating Procedure M.I.C.E.

Caring for your Drain Tube at Home

VET /2018-E VETPUMP 2. Precision Suction & Irrigation System

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

FAULT FINDING. Water Gas Cassette Toilet FAULT FINDING

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

A-dec 300 Support Systems

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

CAL. 7T62, YM62 ALARM & CHRONOGRAPH

Glovebox Usage Manual v1.4. When you enter the lab walk straight to the log book. Enter all information including N2 and O2/H2O levels.

Simple to Set Timer (SST) Frequently Asked Questions

Apex E Quick Installation Guide

PORTABLE AIR CONDITIONER

A3G Green Rotary Laser SPECIAL EDITION INSTRUCTION MANUAL

Suction unit Victoria

Sapphire TM. Bring Home The Future Of Infusion Care. Ambulatory Infusion System. > Intuitive, easy-to-use touch screen design

Ohio Medical is the only name you need to know for your medical suction and oxygen therapy and medgas equipment needs.

INSTALLATION & OPERATION MANUAL

Portable Air-conditioner

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

Torrent irrigation pump Reorder No Operating and Maintenance Manual

Table of Contents. English

740 SELECT. Multi-Parameter Monitor

AVAC9000W Portable Air Conditioner with 24 hour timer Installation Instructions and User Guide

MEDIST s.r.o., Petrusovskeho 4, Humenne, Slovakia Tel.: , Fax: ,

Short Instruction for Use for in-home care ASSKEA procuff M and ASSKEA procuff S

Syringe Pump. Syringe Pump. Product Model: ZD-50C6 Syringe Pump. ZD-50C6-H Syringe Pump

APC BC300 Series 40kW 208/450/480V User Guide

FIREPLACE INSTALLATION

QUARTZ YACHT TIMER WITH DATE AND ALARM

Operating Instructions. Transair Alternating Pressure Care Mattress Replacement System

Gomco Suction Equipment

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Trouble Shooting and Help Guide TT / TTB 1840

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

HERCULES (110V) (220V) USER S MANUAL

Instructions. Portable Absorb Phlegm. Apparatus

KEEP FOR FUTURE REFERENCE 1 SCFM NOMINAL AIRFLOW SINGLE VACUUM SYSTEM DC-VOLTAGE POWER SYSTEM WITH MANUAL VALVE

ALLERGEN MIXING ASSISTANT

Thermo 230 / 231 / 300 / 301 / Troubleshooting

Transcription:

Rocket Quick Guide Rocket PSU Portable Suction Unit

Contents Changing the PSU and changing the clock time...3 Attaching the suction unit to the chest drain bottle...4-5 Operating instructions...6-8 Changing suction levels...9 Information screens...10 Switching the unit off...11 Disconnecting the suction unit from the chest drain bottle...11 2

Rocket Quick Guide Rocket PSU Portable Suction Unit IMPORTANT: The suction unit battery is not charged. DO NOT CONNECT TO A PATIENT IMMEDIATELY UPON OPENING. 1. Remove all packaging for the device and the power supply. 2. Connect the correct mains lead to the supplied 18V power supply module and connect to an electrical supply. 3. Connect the power supply to the PSU, the power supply connection port is on the back of the device. It is protected, and is behind the door marked 4. Charge the device for approximately, 3hrs until the battery display is full. Changing the clock time Please check the time on the device and if required change to local time. The clock time can be changed in 2 ways: 1. On the new patient screen press button 1 and while holding button 1 press button 3. New Patient Press 1st and hold. Then press. 2. By using the software program see full operators guide for instructions on how to do this. 3

Attaching the suction unit to the chest drain bottle 1. Remove red bayonet sealing cap by rotating anti-clockwise from CLOSE to OPEN position. 2. Prime the bottle with 500mls of sterile water attach tubing set to bottle by inserting straw and cap into aperture and twisting clockwise until clicked shut. Take care not to touch the straw. Remove 3. Once underwater seal has been established, place bottle on the floor and connect drainage catheter to tubing connector. 4. Remove the blue handle and the green venting cap from the chest drain. 5. Unwrap the filter from packaging. 6. Place filter on to the suction port of the R54500 or R54509 Chest Drainage bottle. 7. Ensure when placing the filter the location peg is placed in the aperture which the green venting cap was in. The PSU can now be attached to the chest drain bottle. Suction Port Filter location aperture CAUTION: If the filter is contaminated by fluid, the level of suction could be compromised. The filter is designed to protect the pump mechanism from fluid ingress. If contaminated, the filter set MUST be replaced immediately. 4

Rocket Quick Guide Rocket PSU Portable Suction Unit 8. Place the PSU over the filter unit, so the filter will fit into the filter recess under the suction unit. 9. Place the PSU onto the chest drain unit. With slight downward pressure rotate the locking ring clockwise (when facing the unit) so that it locks into position. Lock Unlock 5

Operating instructions Setting Decision Buttons 1. Press for longer than 2 seconds to turn the device on. The unit will begin a self-test. If the self-test is unsuccessful see the trouble shooting instructions on page 24 in the Operators guide. During set up you can confirm or cancel your decisions using the three buttons at the side of the screen. 2. Verify if the PSU is connected to a new patient. THIS INFORMATION IS IMPORTANT FOR THE DATA READING & RECORDING. YES New patient number is issued. NO Patient number is unchanged: New Patient Recommended for continued treatment of the same patient. Data recording is continued. 6

Rocket Quick Guide Rocket PSU Portable Suction Unit If you press you will progress to the next screen. Please verify that you have changed the filter, by pressing or to confirm your decision. If you press you will be taken to the next set up screen. If you press you will be asked to change the filter and the unit will shut down. Remove the suction unit and change the filter as per the instructions, re-fit the PSU to the chest drain bottle and switch on the unit again to restart the set up process. If you press you will be asked to confirm if you need to change the filter. If you have changed the filter press and you will then be taken to the next set up screen. If the filter requires replacing press you will be asked to change the filter and the unit will be shut down. Remove the suction unit and change the filter as per the instructions, re-fit the PSU to the chest drain bottle and switch on the unit again to restart the set up process. 7

Operating instructions 3. Confirm your unit of measurement. The PSU can measure ve pressure in KPa, cmh2o and mmhg. Select units of measure KPa cmh 2 O mmhg 4. You will be asked to confirm your decision. 5. Set the amount of suction required. Using increase or decrease buttons until you are at a level you deem satisfactory. The levels of suction applied increase in -0.5KPa, -5cmH2O and 3.75mmHg increments. There is a gravity drainage setting of 0.25KPa. When you are happy with the set level of suction press Confirm Units of measure -0.5 KPa Set level of suction 6. You will be asked to confirm your decision. If you press you will be taken back to the previous screen where you can confirm your preferred unit of measurement. Confirm level of suction Pressing AND holding for over 2 seconds will commence the application of suction to the chest drain unit and to the patient. 8

Rocket Quick Guide Rocket PSU Portable Suction Unit Changing suction levels If at any time the level of suction required needs changing then press buttons 2 & 3 together for longer than 2 seconds. This will return you to the suction level setting screen. Repeat instruction number 5 to change the level of suction required and instruction 6 to confirm. When the suction unit is in situ and suction is applied 4 different display modes are available to view. Scroll through the 4 screens by pressing button number 1. Press together Press 9

Information Screens Screen 1 Suction level and flow rate. The flow rate, is the volume of air being removed by the pump in L/min. -0.5 KPa 0.5 Suction Flow/Rate L/min 1 Screen 2 Suction level and time of suction applied. -0.5 KPa -1Hr 30m Suction Time 2 Screen 3 Flow vs Time Graph. The graph shows the flow and pressure progression as a function of time. The screen shows 24 hours of use and is updated every 12 minutes. 4 hours are necessary to have a representative graph. Flow Time 3 Screen 4 Air leak indicator, if the patient has a 4 hour period where the suction pump is not engaged, this is classed as the patient having no air leak, the indicator will change colour. This will scroll through as each 4 hour block passes. This is an indication only, further clinical checks should be performed; such as an x-ray prior to chest drain removal. No Air-Leak Indicator 4 8 12 16 20 24 4 10

Rocket Quick Guide Rocket PSU Portable Suction Unit Switching the unit off When this has been completed turn the device off by pressing and holding for longer than 2 seconds. Press to shut down device. Shutdown Device? Disconnecting the suction unit from the chest drain bottle With slight downward pressure rotate the locking ring anti-clockwise. 1. Lift for chest drainage bottle. 2. Remove filter from bottle and dispose of. 3. Recharge PSU in preparation for next use. Lock Unlock 11

Rocket Medical plc. Sedling Road Washington Tyne & Wear NE38 9BZ England Customer Services: 0191 419 6988 www.rocketmedical.com ZDOCK293 Rev.01 03/2017