Gas cooler series RC 1.1

Similar documents
Gas cooler series RC 1.1

Gas cooler series TC-Standard+

Gas cooler series TC-Standard+ X2

Portable sample gas conditioning PCS.smart

Peristaltic condensate pumps CPsingle, CPdouble X2 (Versions with ATEX 2, IECEx and Cl.1 Div.2 approval)

Portable sample gas conditioning PCS.smart+

Sample Gas Probes Series GAS 222

System Components and Accessories for Sample Gas Conditioning. Data Sheet 10/ EN June 2004

HYGROPHIL H process hygrometer

Portable sample gas conditioning. PCS.smart (+) Installation and Operation Instructions. Original instructions. Analysentechnik BE /2017

VC-1, VC-1-SL, VC-2-L, VC-2-SL

REFRIGERANT AIR DRYERS

REFRIGERANT AIR DRYERS

2 OZONFILT And Bono Zon Ozone Plants

Compact Gas Conditioning MAK10

Company profile. ANKERSMID is a privileged partner of several companies like Siemens, BASF, Bayer, Umicore, Dräger and many more.

The Safest Connections...

Portable sample gas conditioning. PCS.smart (+) Installation and Operation Instructions. Original instructions. Analysentechnik BE /2018

NEOTeCHA Reactor Sampling Type PV

Heated Gas Sampling Probe PSG Basic

Safety vacuum drying oven for flammable solvents

Micro/Ultra Filtration System StamoClean CAT 430

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Emission Monitoring System

Operating Temperature/Pressure Graphs: Flow Sensors

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

M7100 Pressure Transducer

gas monitoring system

Control unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr

Introduction to Flow Switch

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

Chemical Pumps Vertical Chemical Pump Type TNP

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Date: Bid Date: Model: i200 i200p. Project Name: Project #: Location: Fuel Type: Natural Gas Propane. Engineer: Contractor: Key Features.

A-DRY Heatless adsorption compressed air dryers

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

Infrared Detectors. Special-Sensors for. Automation

KMF Environmental test chamber for constant climate

Technical data sheet. Lyovapor L-300

VD 53 - Vacuum drying oven for non-flammable solvents

Filters & Centrifugal Separators

Vacuum drying oven for non-flammable solvents

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar abs) Press. (bar g) (kg)

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

TDS Conductivity Probe In-Line conductivity measurement

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

iq1001, Gen II Submittal Data

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

portable gas analyser

Duct Temperature Sensors

Recirculating Coolers

Measurement Solutions for Refrigeration Technology.

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

OPTISENS TUR 2000 Technical Datasheet

VERSO Air Handling Units

Compressed air treatment. Condensate drains OMEGA AIR

OIL FREE WATER INJECTED SCREW COMPRESSOR WIS 40-75

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Ultra Low Gas Cooler Series EC EC30 and EC-30/FD

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Constant climate chambers

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

EC Ultra Low Gas Cooler EC-30C Instruction Manual Version Software Version 1.00

BC-R10 Series. Burner Controllers

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

Thermo Scientific Air Cadet

2 OZONFILT And Bono Zon Ozone Plants

New Generation KBF 240 series

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Users Manual Pury 250e Gas Purification System

Constant climate chambers

Chemistry diaphragm pumps

AirCel. AG Aluminum. SH Steel. Industrial Filter Housings

Installation plan: PG Mat. no Version 00 US

ZERO AIR GENERATOR MODEL 7000 INSTRUCTION MANUAL

i200, Gen II i250, Gen II Submittal Data

Dust Concentration Meter

Cabinet Cooler Systems

OEM Sensors for HVAC manufacturers Heat recovery Chiller

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

Measurement Solutions for Refrigeration Technology.

FIPA Vacuum Components

VACUUM HEATING AND DRYING OVENS Gentle and safe

ThermoDual Domestic hot water charging system

Signet V(D) to V(D) PVDF Conductivity Electrodes

Hand Held Welding Guns

Oil burners fuel unit with solenoid valve

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

portable gas analyser

Sintrol Snifter A1+ Manual. Version 1.2.2

INTRODUCTION / TABLE OF CONTENTS

FluidAqua Mobil FAM 5

VERSO Air Handling Units

Advantages / Characteristics

hinge right B 1 85 cm + 6,5-7 cm max. height of the device feet B cm B 3 85 cm D 2 75 cm (with a maximum opening angle of 170 )

SIHI Dry GD S Sizes S450, S650

Shop. Item Information. Interface I-100 For V-100/V-7x0. Send item information. Show item in shop. Add item to cart.

Transcription:

Gas Analysis Gas cooler series RC 1.1 In the chemical industry, petrochemistry or biochemistry, reliable process control relies on prompt and exact determination of the operating parameters. Here, gas analysis is the key for safe and efficient control of process flows, environmental protection and quality assurance. This benefits controlling flue gas emission in power stations or exhaust gas analysis in automotive engineering, as well as the efficient control of air separators or sterile production and packaging in the food industry. Many of the analysis processes used in these fields require extracting the sample gas. This inevitably also extracts process-related contamination such as particles or moisture. These in turn can impact the measurement results or damage the measuring cells. The sample gas must therefore be conditioned before entering the analyser. The RC 1.1 is a compressor sample gas cooler for up to 2 gas paths and is an essential component for sophisticated analysis systems. Compact design: Pre-installed and ready to connect One or two gas paths Heat exchanger made from stainless steel, Duran glass and PVDF Bühler constant control system Self-monitoring Cooling block temperature display Status alarm Rated cooling power 341 Btu/h Dew point stability 0.2 F CFC-free Moisture detector, analogue output, filter and condensate pump optional Successor to the EGK 1/2 and EGK 1SD DA450028 11/2018 page 1 / 6 Buhler Technologies LLC, 1030 West Hamlin Road, Rochester Hills, MI 48309 Phone: 248.652.1546, Fax: 248.652.1598 e-mail: sales@buhlertech.com Internet: www.buhlertech.com

Gas cooler technical data Gas Cooler Technical Data Ready for operation Rated cooling capacity (at 77 F) after max. 15 minutes 360 kj/h Ambient temperature 41 F to 122 F Gas outlet dew temperature, preset approx. 41 F Dew point fluctuations static: in the entire specification range: ± 0.1 K ± 1.5 K IP rating IP 20 Housing Packaging dimensions Weight incl. heat exchanger Stainless steel approx. 16.5 x 17.3 x 13.8 in approx. 33.1 lb Electric supply 115 V, 60 Hz or 230 V, 50/60 Hz ± 5% Plug per DIN EN 175301-803 Electrical data 230 V 115 V Alarm output switching connection Installation Technical Data - Options Technical Data Peristaltic Pumps CPsingle / CPdouble Flow rate Vacuum inlet Pressure inlet Outlet pressure Hose Condensate outlet Typical power input: 296 VA 302 VA max. operating current: 2 A 3.5 A max. 250 V, 2 A, 50 VA Connector per DIN EN 175301-803 stand-alone or wall-mounted 0.005 lpm (50 Hz) / 0.006 lpm (60 Hz) with standard hose max. 11.6 psi max. 14.5 psi 14.5 psi Protection class IP 40 Materials Hose: Connections: 4 x 1.6 mm (0.04 in) Analogue Output Cooler Temperature Technical Data Signal Hose nipple Ø6 mm (0.24 in) Screw connection 4/6 (metric), 1/6-1/4 (US) Norprene (Standard), Marprene, Fluran PVDF 4-20 ma or 2-10 V corresponds to -4 F to 140 F cooler temperature Connection M12x1 plug, DIN EN 61076-2-101 Technical Data Filter AGF-PV-30-F2-L Ambient temperature 37 F to 212 F max. operating pressure with filter 29 psi Filter surface 19.4 in 2 Filter mesh 2 µm Dead volume Materials Filter: Seal: Filter element: 6.59 cu. in. PVDF, Duran glass (parts in contact with media) Viton sintered PTFE 2 Buhler Technologies LLC We reserve the right to amend specification. DA450028 11/2018

Technical Data FF-3-N Moisture Detector Ambient temperature 37 F to 122 F max. operating pressure with FF-3-N 29 psi Material PVDF, PTFE, epoxy resin, stainless steel 1.4571, 1.4576 Performance data Cooling capacity (Btu/h) Ambient temperature ( F) Note: The limit curves for the heat exchangers exchanger apply to a dew point of 149 F. Diagram typical installation Sample gas/calibrating gas Cooler Sample gas 1 Sample gas probe 2 Sample gas line 3 Reversing tap 4 Sample gas cooler 5 Automatic condensate drain or peristaltic pump 6 Fine mesh filter 7 Moisture detector 8 Sample gas pump 9 Flow meter 10 Analyser See data sheets for individual component types and data. Heat exchanger description The energy content of the sample gas and the required cooling capacity of the gas cooler is determined by three parameters: gas temperature ϑ G, (inlet) dew point τ e (moisture content) and volume flow v. The outlet dew point rises with increasing energy content of the gas. The approved energy load from the gas is therefore determined by the tolerated rise in the dew point. The following limits are specified for a normal standard operating point of τ e = 149 F and ϑ G = 194 F. The maximum volume flow v max in Nl/h of cooled air is indicated, so after moisture has condensed. If the values fall below τ e and ϑ G, the flow v max may be increased. For example, on the TG heat exchanger the parameter triple τ e = 149 F, ϑ G = 194 F and v = 4.7 lpm may also be used in place of τ e = 122 F, ϑ G = 176 F and v = 6.3 lpm. Please contact our experts for clarification or refer to our design program. DA450028 11/2018 We reserve the right to amend specification. Buhler Technologies LLC 3

Heat exchanger overview Heat exchanger TS TS-I 2) TG TG TV-SS DTS (DTS-6 3) ) TV-SS-I 2) DTS-I (DTS-6-I 3) ) 2) DTG DTG DTV 3) 2) 3) DTV-I Version / Material Stainless steel Glass PVDF Stainless steel Glass PVDF Flow rate v max 1) 8.9 lpm 4.7 lpm 2.6 lpm 2 x 4.2 lpm 2 x 2.3 lpm 2 x 2 lpm Inlet dew point τ e,max 1) 175 F 175 F 149 F 175 F 149 F 149 F Gas inlet temperature ϑ G,max 1) 356 F 284 F 284 F 356 F 284 F 284 F Max. Cooling capacity Q max 427 Btu/h 218 Btu/h 114 Btu/h 427 Btu/h 218 Btu/h 175 Btu/h Gas pressure p max 2321 psi 44 psi 44 psi 363 psi 44 psi 29 psi Pressure drop Δp (v=2.5 lpm) 0.12 psi 0.12 psi 0.12 psi 0.1 psi each 0.1 psi each 0.22 psi each Dead volume V tot 4.2 cu. in. 2.9 cu. in. 7.9 cu. in. 1.7 / 1.5 cu. in. 1.7 / 1.5 cu. in. 1.3 / 1.3 cu. in. Gas connections (metric) G1/4 GL 14 (6 mm) 4) DN 4/6 6 mm tube GL14 (6 mm) 4) DN 4/6 Gas connections (US) NPT 1/4" GL 14 (1/4") 4) 1/4"-1/6" 1/4" tube GL14 (1/4") 4) 1/4"-1/6" Condensate out connections (metric) Condensate out connections (US) 1) Max. cooling capacity of the cooler must be considered 2) Models marked I have NPT threads or US tubes, respectively. 3) Condensate drain only possible with condensate pump 4) Gasket inside diameter G3/8 GL 25 (12 mm) 4) G3/8 Tube 10 mm (6 mm) GL18 (10 mm) 4) DN 5/8 NPT 3/8" GL 25 (1/2") 4) NPT 3/8" Tube 3/8" (1/4") GL18 (3/8") 4) 3/16"-5/16" Dimensions 4.05" Filter (optional) Filter (optional) 6.3" 0.83" 7.97" 1.57" 12.2" 0.59-2.56" Ø7x0.39" 13.43" 3.43" 12.95" 3.72" 9.17" S1 S2 S3 S1 = electric supply S2 = alarm contact S3 = analogue output 4 Buhler Technologies LLC We reserve the right to amend specification. DA450028 11/2018

Ordering instructions Gas cooler The item number is a code for the configuration of your unit. Please use the following model key: 4596 2 1 1 0 X X X X X 0 X X X 0 0 0 0 0 Product Characteristics Voltage 1 115 V, 60 Hz 2 230 V, 50 Hz Heat exchanger 1 1 0 1 gas path, stainless steel/ (TS), metric 1 1 5 1 gas path, stainless steel/ (TS-I), US 1 2 0 1 gas path, glass/ (TG), metric 1 2 5 1 gas path, glass/ (TG), US hoses 1 3 0 1 gas path, PVDF/ (TV), metric 1 3 5 1 gas path, PVDF/ (TV-I), US 2 6 0 2 gas paths, stainless steel/ (DTS), metric 2 6 1 2 gas paths, stainless steel/ (DTS-6) 1), metric 2 6 5 2 gas paths, stainless steel/ (DTS-I), US 2 6 6 2 gas paths, stainless steel/ (DTS-6-I) 1), US 2 7 0 2 gas paths, glass/ (DTG), metric 2 7 5 2 gas paths, glass/ (DTG-I), US hoses 2 8 0 2 gas paths, PVDF/ (DTV) 1), metric 2 8 5 2 gas paths, PVDF/ (DTV-I) 1), US Condensate drain 2) 0 0 without condensate drain 1 0 CPsingle with adapter, angled 3) 2 0 CPdouble with adapter, angled 3) 3 0 CPsingle with screw connection, metric/us 3) 4 0 CPdouble with screw connection, metric/us 3) Filter/moisture detector 0 0 without filter, without moisture detector 0 1 without filter, 1 moisture detector 0 2 without filter, 2 moisture detectors 1 0 1 filter, without moisture detector 1 1 1 filter, 1 moisture detector 1 2 1 filter, 2 moisture detectors 2 0 2 filters, without moisture detector 2 1 2 filters, 1 moisture detector 2 2 2 filters, 2 moisture detectors Status outputs 0 0 status output only 1 0 Analog output option, add-on 1) Condensate outlets only suitable for connecting peristaltic pumps. 2) Peristaltic pumps also available for separate installation, see data sheet 450020. 3) Each gas path equipped with a peristaltic pump. The supply voltage corresponds with that of the main unit. DA450028 11/2018 We reserve the right to amend specification. Buhler Technologies LLC 5

Consumables and accessories Item no. Description 44 10 00 1 Automatic condensate drain 11 LD V 38 44 10 00 4 Automatic condensate drain AK 20, PVDF 44 10 00 5 Condensate trap GL 1; glass, 0.4 L 441 00 19 Condensate trap GL 2; glass, 1 L 4492 0035 012 Norprene replacement hose with angled connections for CP peristaltic pump 0.005 lpm 4492 0035 016 Norprene replacement hose with one angled connection and one screw connection (metric) for CP peristaltic pump 0.005 lpm 4492 0035 017 Norprene replacement hose with one angled connection and one screw connection (US) for CP peristaltic pump 0.005 lpm 6 Buhler Technologies LLC We reserve the right to amend specification. DA450028 11/2018