Condensing Boilers. Floor Mounted - Evomod, Imax Xtra & Imax Plus III. Commercial Heating Solutions.

Similar documents
Evomod. Floor Standing Condensing Boilers. Commercial Boiler Solutions.

range W, Plus Condensing boilers kW Commercial & Industrial Boilers

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges

superrange Super Series 4, Super Plus High efficiency modular boilers kW Commercial & Industrial Boilers

INSTALLATION AND SERVICING

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

IMAX XTRA EL FLOOR STANDING CONDENSING BOILERS kW IDEALCOMMERCIALBOILERS.COM

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Pressure Jet Boilers. Pressure Jet Range. Commercial Heating Solutions.

pressurejetrange Buccaneer GTE, Falcon GTE, Harrier GTE, Viceroy GT, Viscount GTE, Vanguard L Pressure jet boilers kW

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

IDEAL LOGIC HEAT INTERFACE UNITS (HIUs) PRODUCT GUIDE.

pressurejetrange Buccaneer GTE, Falcon GTS, Harrier GTS, Viceroy GTS, Viscount GTS, Vanguard L Pressure jet boilers kW

INSTALLATION AND SERVICING

Sirius FS. Working towards a cleaner future

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

EVOMAX CONDENSING BOILER

Hamworthy Fleet Horizontal Floor Standing. Condensing Boilers Natural Gas Outputs 40kW to 350kW 5 YEAR HEAT EXCHANGER WARRANTY

INDEPENDENT COMBINATION & SYSTEM BOILERS.

EVOMAX CONDENSING BOILER

EVO S CONDENSING BOILER

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

EVOMAX CONDENSING. PRODUCT & FLUE GUIDE IDEALCOMMERCIALBOILERS.COM

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Hamworthy Fleet Vertical Floor Standing. Condensing Boilers Natural Gas Outputs 80kW to 1050kW 5 YEAR HEAT EXCHANGER WARRANTY

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

ENERGY TOP. Condensing boiler solutions

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Hamworthy. Fleet Wall Hung. Condensing Boilers Natural Gas Outputs 40kW to 150kW 5 YEAR HEAT EXCHANGER WARRANTY

Sirius WH. Working towards a cleaner future

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Compact HE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

CP+ Gas & Oil Cabinet Heater Range

S-AF Floor Standing Condensing Boiler kW

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

GENERAL. Table 2 General Data Boiler W45 W45P W60 W60P W80 W80P 2H - G20-20mbar / 3P - G31-37mbar

INSTALLATION AND SERVICING

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

CBX 24, 32 & 38 SBX 30

Assessment Schedule - TS.6

HALSTEAD Ace INSTALLATION & SERVICING INSTRUCTIONS FOR THE

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW

GB24 & GB30. User Manual

GENERAL. Note. To obtain gas consumption in l/s, divide gross heat input in (kw) by a calorific value of 37.8 (MJ/m 3 ).

Finest. HALSTEAD Finest Finest Gold INSTALLATION & SERVICING INSTRUCTIONS FOR THE

The iqe Boiler Range. Combination and System T Boilers.

Hamworthy. Purewell VariHeat

VORTEX BLUE OIL RANGE

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

VORTEX BLUE OIL RANGE

GRANT. Euroflame Condensing Oil Boilers. USER, INSTALLATION and SERVICING INSTRUCTIONS

INSTALLATION AND SERVICING

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

thermocompact High performance system boiler range

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

Light commercial products. High output boilers Cascade systems

Concord Super Series 4

IDEAL. Concord CXA INSTALLATION & SERVICING MANUAL. Installers guide to commercial central heating boilers

Osprey 2 CFL

VPC Gas Cabinet Heater Range

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

ecomax pro High efficiency condensing boiler range for traditional systems

turbomax plus High performance combination boiler range

Ace and Ace High. Installation and Servicing Instructions To be left with user adjacent to gas meter. Wall Mounted Gas Combination Boiler

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

Hamworthy. Wessex Modumax. High Efficiency, Fully Modulating Boilers Condensing & Non Condensing, Pre-mix, Gas Fired. Outputs 100kW to 750kW

Natural Gas Models Only Minimiser G.C. Appliance No. FF FF FF

Logic+ Combi

NEW BUILD YOUR COMPLETE SOLUTION.

Installation and Servicing Instructions. Alpha CD24C/32C

Flue & Chimney Systems

ARES Tec HIGH OUTPUT MODULAR CONDENSING BOILER RANGE

USER S INFORMATION MANUAL

CNTENTS. 1Introduction

Installation and Servicing Instructions. Alpha CD50

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

aquaplus High performance combination boiler with integrated power store

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

Compact. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

WHE 2.24 / WHE 2.24 FF

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

TopGas Wall Hung Condensing Gas Boiler

INSTALLATION AND SERVICING

VBX 18 & 30. Eden X Type INSTALLATION AND SERVICING INSTRUCTIONS OPEN VENT CONDENSING BOILER. SINGLE PAGES 20/9/10 09:58 Page 1

2 Concord CX - Installation

ecotec plus New high efficiency condensing combination and system boiler ranges

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Transcription:

Condensing Boilers Floor Mounted - Evomod, Imax Xtra & Imax Plus III www.idealcommercialheating.com Commercial Heating Solutions

Introduction - Ideal Commercial & Industrial Pioneering heating solutions since 1905 Here at Ideal, we understand that you want a reliable, long term partner that has the skills and expertise to deliver you a wide range of reliable and pragmatic solutions. As well as being able to help you rise to the challenge of the UK building regulations, we also provide a dedicated support service throughout the design, planning and after sales stages, giving you total peace of mind that we will provide you with the complete one-stop solution, all from one manufacturer. With over 100 years of manufacturing experience, you can be confident to know that our capabilities stretch beyond traditional boiler technologies Ideal Commercial Heating provides a range of condensing solutions both wall hung or floor mounted, all perfectly designed to meet your individual building requirements. When you choose to partner with Ideal you can be confident to know that you re partnering with a British manufacturer that s supported by a dedicated national service team, delivering help and advice to you and your customers throughout the year. We have been keeping British buildings warm for over a century and believe in making products which are reliable, energy efficient and easy to use, combining the latest technology with common sense engineering that make our products easy to specify, simple to install & maintain and most importantly are reliable.

Contents Condensing boilers 4-19 Evomod (250-1000 kw) 20-29 Imax xtra (80-560 kw) 30-37 Imax plus III (95-330 kw) 38-39 Imax range system requirements 40 Evomod system requirements Ideal Service & Support 42 Ideal Service & Support 03

Floor Mounted Condensing Boilers Evomod Evomod 250-1000 kw With premix burner technology and a stainless steel heat exchanger, the Evomod range of boilers are capable of high operating efficiencies and low emissions that contribute to reducing running costs and are certified to meet the requirements of the Boiler Efficiency Directive. The Evomod range introduces fully condensing modular benefits to higher outputs in a steel frame of up to 3 high stacking, providing minimum floor area that makes access through a standard (700mm frame width) doorway possible. When required in a difficult area of installation, the modular construction of the frame can be broken down into individual heat exchanger modules. Each module provides a maximum of 250 kw heat output and will modulate down through a sophisticated control system. In this way a decreasing load is continuously matched for optimum efficiency, by modulating one module at a time. Available in 250, 500, 750 and 1000 kw, the Evomod will achieve an output up to 1MW from a single unit solution together with a minimum footprint that enables the product to be installed where space is limited. 04

The Evomod is not only simple to operate with its simple controls interface with large backlight display, it is also an extremely compact unit making design easier as the boiler uses minimum floor area. Installation of the range is made easier as the Evomod has smaller parts and is lighter in weight than many other floor mounted boilers. The option of assembled, or on site assembly also adds to this. Maintenance is also made simple through the boilers valved header kits. The Evomod range comes complete with two years parts and labour warranty as standard and as with all products from Ideal Commercial is completely manufactured and built in the UK. Features and Benefits Made in the UK 2 Year Warranty Floor Standing NOx Class 5 - Heat maintained during service - Easier installation as lighter, smaller parts 05 Condensing

Commercial Heating Solutions Evomod 250-1000 kw Performance data Model 250 500 750 1000 Mean 70 C Mean 40 C Boiler Input Max Rate Boiler Input Min Rate Gas Rate Max Min Max Min Gross Gross Max Rate kw 232.5 465 697.5 930 793,378 1,586,774 2,350,184 3,173,512 kw 46.7 46.7 46.7 46.7 159,325 159,325 159,325 159,325 kw 252.5 505 757.5 1010 861,530 1,723,060 2,584,590 3,446,120 kw 51.4 51.4 51.4 51.4 175,404 175,404 175,404 175,404 kw 238 476 714 952 812,056 1,624,112 2,486,168 3,248,224 264.1 kw 264.1 523.2 792.3 1056.4 901,109 1,802,218 2,703,327 3,604,436 kw 47.6 47.6 47.6 47.6 162,411 162,411 162,411 162,411 kw 52.8 52.8 52.8 52.8 180,256 180,256 180,256 180,256 m 3 25.2 50.4 75.6 100.8 ft 3 889.9 1779.8 2,669.7 3,559.6 Approx. flue gas Max Rate i.e. noncondensing m 3 391 783 1174 1566 volume (@80 C) ft 3 13,808 27,615 41,459 55,303 Max. Flue Resistance Pa 105 105 105 105 2 Max Rate % 9.1 ±0.2 9.1 ±0.2 9.1 ±0.2 9.1 ±0.2 Min Rate % 8.4 ±0.2 8.4 ±0.2 8.4 ±0.2 8.4 ±0.2 39.7 39.7 39.7 39.7 ppm 22.5 22.5 22.5 22.5 Seasonal Boiler Efficiency % 95.9 95.9 95.9 95.9 Optional kits Included as standard Boiler Evomod Boiler Evomod Water & gas header assembly packaged Remote indication (run & alarm) standard Hours run standard Water connection kit (250) BMS (0-10v) operation standard Air inlet collar Pump overrun standard including 5 line plain text display standard 06

General data Model 250 500 750 1000 Gas Supply 2H - G20-20mbar Gas Supply Connection (in. BSP) R1¼ R2 R2 R2 ½ Flow Connection (in. BSP) Return Connection (in. BSP) Hydraulic Resistance @ 20 C (with optional water header pack fitted) mbar 100 105 110 120 Max Press (sealed system) bar (psi) 6 (87) Maximum Static Head m (ft) 61 (200) Boiler Electricity Supply Boiler Fuse Rating 1 x 5A Internal 2 x 5A Internal 3 x 5A Internal 4 x 5A Internal Power Consumption (boiler only) W 350 680 1020 1350 Air Inlet (optional) 300 300 300 300 x 2 mm 150 250 250 300 Condensate drain mm 21.5 2 x 21.5 3 x 21.5 4 x 21.5 Boiler dry weight (unpacked exc. headers) kg 229 420 611 845 Water Content l (gal) 14.8 (3.26) 29.6 (6.52) 44.4 (9.78) 59.2 (13.0) IP Rating IP20 Electricity supply and Fuse rating for pumps etc. refer to manufacturer's instructions. 3 3 3 3 ) nett at 15 C and 1013.25 mbar. 3 ) 3 3 ) c. For M 3 Boiler Clearances The minimum dimensions as indicated must be respected to ensure good access around the boiler. Recommended minimum clearances are as follows. Rear: 750mm or adequate space from the rear of the jacket to make the flue connections, drain connection, flue and any safety or control devices. Left Side: 400mm Right Side: 450mm Front: 600mm for normal service and replacement of components. However, it is noted that 1.2m is required in the event of heat exchanger replacement. Top: 300mm (clearance above boiler casing). 07 Condensing

Commercial Heating Solutions Boiler assembly - exploded view Key 1 Fan 4 Burner Sequence Controller 5 Mains Connection Box 6 Heat exchanger 7 Thermistor (flow) 8 Thermistor (return) 9 Condensate Blockage Pressure Switch 10 Ignition Electrode 11 Detection electrode 13 Flue Sampling Point 14 Water Pressure Switch 15 Condensate Debris Collector 08

Evomod 250 - Dimensions All dimensions shown in mm Back View Side View Front View EVOMOD 250 09 Condensing

Commercial Heating Solutions Evomod 500 - Dimensions All dimensions shown in mm Back View Side View Front View EVOMOD 500 10

Evomod 750 - Dimensions All dimensions shown in mm Back View Side View Front View EVOMOD 750 11 Condensing

Commercial Heating Solutions Evomod 1000 - Dimensions All dimensions shown in mm Back View Side View Front View EVOMOD 1000 12

Header kits - Evomod 500 All dimensions shown in mm EVOMOD 500 KW HEADER ASSY (Note: Optional header includes valves shown. Dimensions for optional header without valves also provided.) 13 Condensing

Commercial Heating Solutions Header kits - Evomod 750 All dimensions shown in mm EVOMOD 750 KW HEADER ASSY (Note: Optional header includes valves shown. Dimensions for optional header without valves also provided.) 14

Header kits - Evomod 1000 All dimensions shown in mm EVOMOD 1000 KW HEADER ASSY (Note: Optional header includes valves shown. Dimensions for optional header without valves also provided.) 15 Condensing

Commercial Heating Solutions System application Ideal Evomod boilers are designed for central heating of large domestic and commercial premises and also for supplying domestic hot water via a domestic hot water systems. Boiler Evomod 61 metres (200 feet) 6 bar (87psi) Maximum design flow temperature is 80 C (180F) Pump overrun is provided as standard, and a period of 2 minutes must be allowed for in system design. Frost protection is built into the boiler control, if the boiler sensor falls below 5 C, this will result in the appliance firing. This will protect the boiler only, not exposed system elements. Range packaging Evomod 250, 500, 750 The boiler is delivered on a wooden pallet with protective cardboard packing pieces at the front. The side panels & bottom side panels are contained within cardboard packs strapped to the sides of the boilers. The footer is contained in a cardboard box, strapped to the boiler, or placed on the flue header pallet. All condensate traps are individually boxed & stored within the footer box. A protective plastic wrap protects the contents of the pallet. The flue components are in a cardboard box on a separate pallet. The water connection kit (250) comes in a separate box, the header kits (500, 750, 1000) come on a separate pallet. Evomod 1000 This boiler comes packed as above except the boiler is split onto 2 pallets. The header assembly comes split across 2 pallets + a gas manifold. 1. Boiler on pallet(s) 2. Side panel pack(s) 3. Footer pack(s) inc. condensate traps 4. Flue components boxes, store in a safe place safe place boxes from within the footer box, store in a safe place. packing from the front. wooden pallet & disassemble the pallet. A full commissioning service is available at an extra charge. 16

Minimum water flow Due to the compact nature of the boiler the heat stored within the heat exchanger at the point of shutdown of the burner must be dissipated into the water circuit in order to avoid overheating. In order to allow pump operation after burner shutdown the boiler control box incorporates a 2 minute pump overrun facility. In order to make use of this, a pump must be controlled via the terminals inside the boiler. System design must allow for adequate internal circulation and sufficient heat release from the boiler body whenever the burner is firing or during pump overrun. (See flow rate table below for details). Additionally, the system must be controlled so that part of the load is available during the pump overrun period to dissipate heat. Pump Choice: The choice of pump should take into account the hydraulic resistance given in the table below. Flow rates for common systems using a 20 C temperature differential are given in the table below. Model 250 500 750 1000 Hydraulic resistance at 20 C Water flow rate temperature difference 20 C (36 F) mb 410 410 410 410 in. w.g. 164 164 164 164 3.0 6.0 9.0 12.0 m 3 10.7 21.5 32.2 43 differentials will lead to poor system performance. because the water in the flue gases starts to condense, releasing its latent heat. In installations where all radiators have been provided with thermostatic radiator valves, it is essential that water circulation through the boiler is guaranteed. A mixing header will perform this task. Alternatively this can be best achieved by means of a differential pressure valve, which is installed in a bypass between the flow and return pipes. The bypass should be fitted at least 6m from the boiler, and should be capable of allowing a minimum flow rate to achieve a temperature differential of no greater than 35 C at minimum rate. 17 Condensing

Commercial Heating Solutions Ventilation The ventilation requirements of these boilers are dependant on the type of flue system used, and their heat input. All vents must be permanent with no means of closing, and positioned to avoid accidental obstructions by blocking or flooding. Detail reference should be made to BS. 6644 for inputs between 70kW and 1.8MW (net). Dust contamination in the combustion air may cause blockage of the burner slots. Unless the boiler room provides a dust free environment then direct connection of the air intake via ducting to clean outside air should be used. IMPORTANT NOTE: If combustion air is drawn from within the boiler room, ensure no dust or airborne debris can be ingested into the appliance. Dusty concrete flooring should be sealed to reduce the presence of dust. The temperature within a boiler room shall not exceed 25 C within 100 mm of the floor, 32 C at mid height and 40 C within 100 mm of the ceiling. Open Flued Installations below. For other ventilation options refer to BS. 6644. In IE refer to the current edition of I.S.820. Required area (cm2) per kw of total rated input (net) Boiler Room Enclosure 4 10 High level (outlet) 2 5 of time (refer to BS6644). Water Treatment must be used in accordance with the manufacturers' instructions. Telephone: Telephone: 0800 389 4670. www.sentinel-solutions.net 1. It is most important that the correct concentration of the water treatment products is maintained in accordance with the manufacturers' instructions. 2. If the boiler is installed in an existing system any unsuitable additives MUST be removed by thorough cleansing. 3. In hard water areas, treatment to prevent limescale may be necessary. 4. Under no circumstances should the boiler be fired before the system has been thoroughly flushed. 18

Flue Installation The flue header for 500-1000 boilers is supplied. IMPORTANT. It is the responsibility of the installer to ensure, in practice, that products of combustion discharging from the terminal cannot re-enter the If this should occur the appliance MUST be isolated from the gas supply and labelled as 'unsafe' until corrective action can be taken. Terminal Position Due to the high efficiency of the boilers pluming will occur. Particular care should be taken in the case of large output boiler installations, and complying with the requirements of the Clean Air Act. The flue must be installed in accordance with the appropriate Building Regulations and standards and in compliance with BS6644. Flue system design Due to the high efficiency of these boilers, the flue gas temperatures are low and the buoyancy in the stack will be relatively small. The boiler is supplied with an integral fan which is fully matched to the boiler in each case to provide correct combustion air flow and overcome the flue resistance. The power of this fan is such that there is a large reserve of pressure available to overcome a significant length of flue without affecting the combustion performance of the boiler. The maximum pressure available at the base of the flue to overcome flue resistance is 105Pa. This includes the resistance of any air ducts used to connect the air inlet direct to outside air. Care should be taken with tall flue systems to ensure excess buoyancy is not created. A negative pressure must not be created at the boiler flue outlet. See table below for approximate maximum straight flue length. Boiler 250 500 750 1000 Ø150 Ø250 Ø250 Ø300 Approx. max. Straight Flue 28 80 32 56 The addition of elbows and their positions in the flue will have a significant effect on the maximum allowable flue and air duct lengths. Consult with your flue supplier for detailed design work. IMPORTANT NOTE. If combustion air is drawn from within the boiler room, ensure no dust or airborne debris can be ingested into the appliance. Dusty concrete flooring should be sealed to reduce the presence of dust. Ideally where possible duct the air supply Material With no requirement for buoyancy to discharge flue products and with low flue gas temperatures, single wall flues are suitable for most installations. Care should still be taken to maintain compliance with building regulations and relevant standards. The flue used should be a suitably approved flue for use on a pressurised condensing flue system. The boiler is not suitable for use on plastic flue systems. Condensate produced in the flue should be drained separately before entering the boiler. A Drain point at the bottom of the Header Kit (500, 750 and 1,000) is provided for this purpose. Advice regarding the availability of proprietary types of flue system can be obtained by contacting Ideal Stelrad Group. All joints or connections in the flue system must be impervious to using pipe of material resistant to condensate corrosion. All drains in the flue should incorporate a water trap. Care should also be taken in the selection of flue terminals as these tend to accentuate Care should be taken to ensure the specification of the chimney is suitable for the application by reference to the manufacturers literature. NOTE:- Long Flues It is recommended that a support bracket is fitted at least every 1m of flue length and a bracket must be fitted at every flue joint to ensure flue seal and alignment of flue. 19 Condensing

Floor Mounted Condensing Boilers Imax xtra Imax xtra 80-560 kw The Imax xtra range of condensing boilers is offered in ten models with outputs from 80 to 560 kw suitable for floor standing application in either single or multiple applications. The Imax Xtra range utilises cast aluminium - silicon alloy heat exchangers incorporating a premix burner with gas and air control for excellent efficiency and emission performance. High efficiencies are achieved 95%. Heat exchangers are of sectional build front to back ensuring that all models have the same width, e.g. 600mm (80-280) and 1200mm (320-560). All models are capable of being transported through standard 600mm doorways as 320-560 models are supplied as two modules. The fully modulating burner operation ensures that the boiler operates as efficiently as possible throughout its firing cycle even down to 20% of the maximum rating. This enables the unit to match its output to all system requirements no matter of a microprocessor readily accessible on the boiler front. Commissioning and full fault diagnostics are provided whilst remote indication of boiler run and alarm is standard. A wide range of control options ensures easy application of BMS systems, sequencing and sensor control. The Imax xtra range meets the requirements of the 20

F320-560 models comprise two modules within a single boiler, each being of similar construction to smaller Imax xtra units. The modules operate together to provide the required load with a designated master and slave operation sequence. Flue and air dampers fitted to each module are linked to enhance efficiency and control. This arrangement allows one module to maintain heat under adverse circumstances. Features and Benefits Made in the UK 1 Year Warranty Floor Standing NOx Class 5 21 Condensing

Commercial Heating Solutions Imax xtra 80-280 kw Performance data Model 80 120 160 200 240 280 Mean 70 C Mean 40 C Boiler Input Max Rate Boiler Input Min Rate Gas Rate Max Min Max Min Gross Gross Max Rate kw 77.9 116.9 155.8 195.4 234.5 273.6 265,800 398,900 531,600 666,700 800,100 933,500 kw 23.3 23.3 29.1 43.1 47.0 51.0 79,500 79,500 99,300 147,050 160,350 174,000 kw 82.2 123.4 164.5 207.8 249.4 290.9 280,450 421,050 561,250 709,000 850,950 992,550 kw 25.8 25.8 32.3 47.3 51.6 55.9 88,000 88,000 110,200 161,400 176,050 190,750 kw 80 120 160 200 240 280 272,950 409,450 545,900 682,400 818,900 955,350 kw 88.8 133.3 177.7 222.1 266.5 310.9 303,000 454,800 606,300 757,800 909,300 1,060,800 kw 24 24 30 44 48 52 81,900 81,900 102,350 150,150 163,800 177,400 kw 26.6 26.6 33.3 48.9 53.3 57.7 90,750 90,750 113,600 166,850 181,850 196,850 m 3 8.1 12.1 16.1 20.1 24.2 28.2 ft 3 286 427 569 710 855 996 Approx. flue gas Max Rate i.e. noncondensing m 3 121 182 242 302 363 423 volume (@80 C) ft 3 4,270 6,410 8,550 10,690 12,820 14,960 Max. Flue Resistance Pa 100 100 150 150 150 150 2 Max Rate % Min Rate % 26 26 35 26 26 26 ppm 15 15 20 15 15 15 Seasonal Boiler Efficiency % 95.1 95.1 95.1 95.2 95.2 95.2 General data Model 80 120 160 200 240 280 Gas Supply 2H - G20-20mbar Gas Supply Connection R (in. BSP) 1 1 1 1 1 1 Flow Connection R (in. BSP) 2 2 2 2 2 2 Return Connection R (in. BSP) 2 2 2 2 2 2 Hydraulic Resistance @ 20 C mbar 80 85 90 95 100 105 Max Press (sealed system) bar (psi) 6 (87) 6 (87) 6 (87) 6 (87) 6 (87) 6 (87) Maximum Static Head m (ft) 61 (200) 61 (200) 61 (200) 61 (200) 61 (200) 61 (200) Boiler Electricity Supply Boiler Fuse Rating Power Consumption (boiler only) W 250 250 400 400 400 400 Air Inlet (optional) 110 110 110 110 110 110 mm 150 150 150 200 200 200 Condensate drain mm 21.5 21.5 21.5 21.5 21.5 21.5 Boiler dry weight (unpacked) kg (lb) 132 (291) 150 (331) 168 (370) 198 (437) 215 (474) 233 (514) Water Content l (gal) 11.0 (2.4) 14.3 (3.2) 17.5 (3.9) 18.4 (4.1) 24.0 (5.3) 27.2 (6.0) 22

Imax xtra 320-560 kw Performance data Model 320 400 480 560 Mean 70 C Mean 40 C Boiler Input Max Rate Boiler Input Min Rate Gas Rate Max Min Max Min Gross Gross Max Rate kw 311.6 390.8 469.0 547.2 1,063,200 1,333,400 1,600,200 1,867,000 kw 67.8 97.7 105.5 107.7 231,300 333,400 360,000 367,500 kw 329.0 415.6 498.8 581.8 1,122,500 1,418,000 1,701,900 1,985,100 kw 75.3 107.5 116.1 118.3 256,900 366,800 396,100 403,600 kw 320 400 480 560 1,091,800 1,364,800 1,637,800 1,910,700 kw 355.4 444.2 533.0 621.8 1,212,600 1,515,600 1,818,600 2,121,600 kw 70 100 108 110 238,800 341,200 368,500 375,300 kw 77.6 110.9 119.8 122.0 264,800 378,400 408,800 416,300 m 3 32.2 40.2 48.4 56.4 ft 3 1138 1420 1710 1992 Approx. flue gas Max Rate i.e. noncondensing m 3 484 604 726 846 volume (@80 C) ft 3 17,100 21,380 25,640 29,920 Max. Flue Resistance Pa 145 145 145 145 2 Max Rate % Min Rate % 35 26 26 26 ppm 20 15 15 15 Seasonal Boiler Efficiency % 95.1 95.2 95.2 95.2 General data Model 320 400 480 560 Gas Supply 2H - G20-20mbar Gas Supply Connection (in. BSP) 2 x R1 2 x R1 2 x R1 2 x R1 Flow Connection (in. BSP) 2 x R2 2 x R2 2 x R2 2 x R2 Return Connection (in. BSP) 2 x R2 2 x R2 2 x R2 2 x R2 Hydraulic Resistance @ 20 C (with optional water header pack fitted) mbar 100 105 110 120 Max Press (sealed system) bar (psi) 6 (87) 6 (87) 6 (87) 6 (87) Maximum Static Head m (ft) 61 (200) 61 (200) 61 (200) 61 (200) Boiler Electricity Supply Boiler Fuse Rating 2 x External 5A supplies Internal 2AT.4AT (x2) Power Consumption (boiler only) W 800 800 800 800 110x2 Air Inlet (optional) 110x2 110x2 110x2 110x2 mm 200 250 250 250 Condensate drain mm 2x21.5 2x21.5 2x21.5 2x21.5 Boiler dry weight (unpacked) kg (lb) 336 (740) 396 (874) 430 (948) 466 (1028) Water Content l (gal) 35 (7.8) 36.8 (8.2) 48.0 (10.6) 54.4 (12.0) Electricity supply and Fuse rating for pumps etc. refer to manufacturer's instructions. 23 Condensing

Commercial Heating Solutions Imax xtra 80-280 kw - Dimensions All dimensions shown in mm 110 1150 SIDE VIEW Flue Centre Line High Level Air Inlet Kit (If Fitted) FRONT VIEW 510 A 51 B 600 R2" Flow Connection 125 232 R1" Gas Connection PLAN VIEW Flue OD REAR VIEW 678 Electrical Conduit R2" Return Connection 382 30 333 869 Electrical Conduit Air Inlet O110 C Boiler A B C D 80-160 796 888 1024 150 200-280 1048 1165 1327 200 Recommended minimum clearances are as follows. 125 200 24

Imax xtra 320-560 kw - Dimensions Horizontal Flue Connection Kit Fitted All dimensions shown in mm 110 SIDE VIEW High Level Air Inlet Kit (If Fitted) FRONT VIEW 17 (Condensate Drain) G (Flow & Return) Slave Module Master Module 113 (Air Inlet) 91 (Gas) Flow Connections R2" REAR VIEW Gas R1" PLAN VIEW im9615 Boiler A B C D E F G 320 796 888 1642 411 200 1051 157 Return Connection R2" Air Inlet Ducts O110 400-560 1048 1165 1684 527 250 1352 227 25 Condensing

Commercial Heating Solutions Imax xtra 320-560 kw - Dimensions Vertical Flue Connection Kit Fitted All dimensions shown in mm 110 SIDE VIEW High Level Air Inlet Kit (If Fitted) FRONT VIEW Condensate Drain Slave Module Master Module PLAN VIEW REAR VIEW Return Connection R2" Air Inlet Ducts O110 Boiler A B C D E F G 320 796 888 1732 1632 200 1056 157 400-560 1048 1165 1524 1424 250 1353 227 26

Imax xtra 320-560 kw - Dimensions Optional water and gas header kit and rs air duct connector (F320 & F400 only) fitted All dimensions shown in mm SIDE VIEW REAR VIEW Flow connection Return connection im9159 Note. F320 Model shown Boiler clearances (320-560) Recommended minimum clearances are as follows. any safety or control devices. 27 Condensing

Commercial Heating Solutions Imax xtra Optional kits Boiler Imax xtra 80-280 320-560 Modulating sequence control for controlling multiple boiler installations Programmable room thermostat Tank sensor kit standard Room sensor kit Boiler Imax xtra 80-280 320-560 Sequencer DHW sensor kit Control interface kit standard Flow, return & gas header kit RS air duct connector only Boiler assembly - exploded view 6 49 7 22 24 8 11 38 9 12 2 3 1 19 F280 shown 47 27 33 14 25 37 20 Data plate Key 1. Control fascia panel 2. Burner switch 3. Pressure gauge 5. Casing front panel 6. Casing top panel 7. Casing side panel 8. Fan 12. Control Module 19. Union Gas cock 22. Heat exchanger 24. Sightglass 25. Air inlet 7 27. Burner manifold 33. Air pressure switch 37. Relay 38. Cable conduit 49. Manifold - Flow 5 28

Imax xtra System application Ideal Imax xtra boilers are designed for central heating of large domestic and commercial premises and also for supplying domestic hot water via a domestic hot water systems. Boiler Imax xtra 61 metres (200 feet) 6 bar (87psi) Maximum design flow temperature is 82 C (180F) (This is adjustable to 90 C if required at the control panel). Pump overrun is provided as standard, and a period of 5 minutes must be allowed for in system design. Frost protection is built into the boiler control, if the boiler sensor falls below 7 C, this will result in the appliance firing. This will protect the boiler only, not exposed system elements. Range packing The Ideal Imax xtra 80-280 is dispatched from works as one pack as follows. (readily removed to allow passage through standard doors) A full commissioning service is available at an extra charge. Minimum water flow System design must allow for adequate internal circulation and sufficient heat release from the boiler body whenever the burner is firing or during pump overrun. (See flow rate table below for details). Additionally, the system must be controlled so that part of the load is available during the pump overrun period to dissipate heat. Pump Choice: The choice of pump should take into account the hydraulic resistance given in the table below. Model 80 120 160 200 240 280 Hydraulic resistance at 20 C 11 K (20 F) Minimum water flow rate temperature difference 20 K (36 F) mb 75 100 110 125 140 150 in. w.g. 30 40 44 50 56 60 1.78 2.68 3.57 4.51 5.42 6.32 m 3 6.41 9.65 12.85 16.24 19.51 22.75 0.98 1.47 1.96 2.48 2.98 3.47 m 3 3.53 5.3 7.06 8.93 10.73 12.49 Model 320 400 480 560 Hydraulic resistance at 20 C 11 K (20 F) Minimum water flow rate temperature difference 20 K (36 F) mb 90 95 100 105 in. w.g. 36 38 40 42 7.14 9.02 10.83 12.63 m 3 25.7 32.47 38.99 45.47 3.93 4.96 5.96 6.95 m 3 14.15 17.86 21.46 25.02 29 Condensing

Floor Mounted Condensing Boilers Imax plus III Imax plus III 95-330 kw The Imax plus III offers greater flexibility of installation and operation with outputs from 95kW to 330kW in a range of six compact floor standing boilers. The range can be installed in multiple formation to provide even larger outputs if the system requires. efficiency is maintained down to as low as 11.2kW output, achieved even with the largest model as the unique design optimises load matching. Each boiler comprises of several sections, each flueway or module having its own burner, fan, gas valve, ignition and safety controls. As system load decreases the boiler modulates down to the combined minimum. As load further decreases modules are switched off to further match the reducing load. Wasteful boiler cycling is minimised whilst stand-by back up is built into the design. The range is designed for ease of installation ensuring boiler house siting is as simple and as fast as possible. The Imax plus III is also 30

Advanced microprocessor based controls are used to operate all electrical functions and provide full commissioning and fault diagnostic displays. The units also include Hours Run Meters and BMS control built-in, along with an outside sensor for weather compensation supplied as standard. Features and Benefits 1 Year Warranty Floor Standing NOx Class 5 31 Condensing

Commercial Heating Solutions Imax plus III 95-330 kw Performance data Model 95 145 190 235 285 330 Boiler output (non-condensing) Boiler Input Max Rate Boiler Input Min Rate Gas Rate Max Min Max Min Gross Gross kw 93.2 140 197 234.7 282.2 329.5 317,998 477,680 672,164 800,796 962,866 1,124,254 kw 11.2 38,214 kw 95.9 144.1 192.4 241 289.9 339.4 327,211 491,669 656,469 822,292 989,139 1,158,033 kw 12.7 43,332 kw 96 144 192 240 288 336 327,552 491,328 655,104 818,880 982,656 1,146,432 kw 106.5 159.8 213.1 266.4 319.6 372.9 363,543 545,314 727,085 908,857 1,090,628 1,272,400 kw 12 40,950 kw 13.3 45,400 m 3 10.15 15.23 20.3 25.38 30.45 35.53 ft 3 358 538 717 896 1,075 1,255 Approx. flue gas volume m 3 0.044 0.066 0.087 0.108 0.129 0.150 (non condensing) max rate ft 3 93.1 138.8 183.8 228.6 272.8 317.2 Max. Flue Resistance Pa 100 ppm Seasonal Boiler Efficiency % 94.57 94.6 94.65 94.69 94.72 94.73 General data Model 95 145 190 235 285 330 Flow connection BSP R2 Return connection BSP R2 m 61 Maximum static water head ft 200 Bar 6 Maximum pressure psi 87 Gas inlet connection BSP R1½ Pressure required at the boiler inlet for mbar 15.0 in. w.g. 6.0 Electricity supply mm 150 150 150 200 200 200 mm 150 Condensate drain mm 40 Water content l 10.1 14.2 18.3 22.4 26.5 30.6 gal 2.22 3.13 4.03 4.93 5.84 6.74 kg 156 191 230 272 312 357 Weight lb 344 421 507 600 688 787 Power consumption W 146 210 290 362 435 507 32

Imax plus III 95-330 kw - Dimensions Warning: Flow/return connections change their position whether they are on the R.H. or on the L.H. side of the boiler (see views above). Flue connection shown on RH side, options shown dotted at rear or left. Model 95 145 190 235 285 330 2 3 4 5 6 7 A 695 695 832 968 1102 1236 B 150 150 150 150 200 200 Weight kg 153 182 223 261 301 345 Connections Gas Flow Return Condensate Drain Boiler house clearances service across the full width of the boiler. between boilers. 33 Condensing

Commercial Heating Solutions Imax plus III Boiler construction The construction of the Imax plus III sectional heat exchanger design is of cast aluminium. Individual downfiring burners, fans, gas valves and ignition safety controls for each flueway or module are provided. A non-return valve ensures no reverse circulation of flue products through modules not operating. A stainless steel sump collects the flue products and diverts them to the flue, whilst allowing drainage of condensate products. Multiple Boiler Installations Imax plus III boilers are suitable for installations where the load requires more than one boiler. The flexibility of flue connection position (left, right or rear) and system and gas connections (left or right) allows multiple boilers to be sited more easily in confined boiler homes. Imax plus III boilers can be laid out for example with rear sides facing each other and flues at the same end. Many more options are possible to minimise plant room area. 34

Imax plus III Flue systems To ensure safe and satisfactory operation, the boiler must be connected to a chimney system capable at all times of adequately evacuating the combustion products. Ideal Imax plus III boilers are suitable for use in both room sealed and open flue fan assisted operation. A vertical flue outlet can be positioned to left, right or rear. The air inlet is at the left or right. If installing a room sealed air inlet arrangement, optional air inlet blanking plate kits will be required. The boiler is suitable for use in either single or multiple flue configurations and can be fitted with a wide variety of flue systems. any condensate formed can be discharged through the boiler. All joints or connections in the flue system must be impervious to condensate leakage and also any low points in the flue system should be drained using pipe of material resistant to condensate corrosion. The flue duct termination point must be positioned so that it will not be affected by adverse wind conditions and be free from any obstructions. Therefore where possible terminal positions which could cause problems due to pluming should be avoided. the chimney system without prior consultation with Ideal Stelrad Group. Flues and terminal positions should be designed with strict regard to these for multiple boiler installations and if required, the Clean Air Act. Proprietary flue systems are available for use with this range. A pressure of 100Pa is available at the flue outlet. Optional kits Boiler DHW sensor Mixing circuit sensor Remote indication Hours run meter(s) BMS (0-10v) Air inlet socket and blanking plate kit Cascade control Cascade control wall mounting kit Imax plus III standard standard standard standard standard standard Minimum water flow System design must allow for adequate internal circulation and sufficient heat release from the boiler body whenever the burner is firing or during pump overrun. (See flow rate table below for details). Additionally, the system must be controlled so that part of the load is available during the pump overrun period to dissipate heat. Pump Choice: The choice of pump should take into account hydraulic resistance given in the table below. Model 95 145 190 235 285 330 Hydraulic resistance at 20 C 11 K (20 F) Minimum water flow rate temperature difference 20 K (36 F) mb 110 135 170 250 280 330 in. w.g. 44 54 68 100 112 132 2.02 3.04 4.07 5.18 6.13 7.16 m 3 7.27 10.94 14.65 18.65 22.1 25.8 1.11 1.67 2.24 2.85 3.37 3.94 m 3 4.01 6.03 8.06 10.27 12.14 14.17 35 Condensing

Commercial Heating Solutions System design The efficiency of this range of boilers is higher than conventional boilers because of the increased heat exchange area. At return temperatures of 55 C and below, the differences become more marked because the water in the flue gases starts to condense releasing its latent heat. In general, the lower the return temperature, the better the efficiency. In new systems it is best to design for the lowest flow and return temperatures that are practical (subject to the lower limit mentioned above). For optimum operation it is advised that the system be designed on a temperature differential of 20 C. 36

Imax plus III System application Ideal Imax plus III boilers are designed for central heating of large domestic and commercial premises and also for supplying domestic hot water via domestic hot water systems. Boiler Imax plus III 61 metres (200 feet) 6 bar (87psi) Maximum design flow temperature is 82 C (180F) (This is adjustable to 90 C if required at the control panel). Pump overrun is provided as standard, and a period of 5 minutes must be allowed for in system design. Frost protection is built into the boiler control, if the boiler sensor falls below 7 C, this will result in the appliance firing. This will protect the boiler only, not exposed system elements. Condensate drain Ideal Imax plus III boilers will produce condensate whenever the temperature of the return water from the system is below approximately 55 C (the dew point of the combustion products). Pipework is supplied for fitting beneath the boiler and includes a filling point for initial charging of a condensate siphon (not supplied). The pipe should be installed with an adequate slope (eg 1 in 50) and consideration should be given to frost protection. 37 Condensing

Commercial Heating Solutions Imax Range Ventilation Open flued application Safe, efficient, and trouble-free operation of conventionally flued gas boilers is vitally dependent on the provision of an adequate supply of fresh air to the room in which the appliance is installed. The Imax plus III range is also fitted with air inlet filters for such applications. be according to the scale below. The use of an extractor fan in the same room as the boiler (or in an adjacent room in communication) can, in certain conditions, adversely affect the safe operation of the boiler. Where such a fan is already fitted, or if an extractor fan is likely to be installed at a later date, then the advice of the gas supplier should be obtained. BS 6644 - Inputs greater than 70kW (nett) Total gross input rating of boilers Position of air vents Air vent areas* (cm2) (air direct from outside) 70kW to 1.8MW 70kW to 1.8MW High level Boiler room Enclosure 2 5 Boiler room Enclosure 4 10 requirements are stated. If operating for more than 50% of time refer to BS 6644. Balanced flue applications However, air may be required to ventilate the boiler house and remove any excess heat generated by the boiler (2cm2 free area per kw nett heat input at both high and low level BS 6644). Imax xtra & Imax plus III boilers have an air inlet connection which may be used with proprietary ducting if required. A separate flue connection is still required. Water Treatment the mains is treated. For these reasons Ideal Boilers strongly recommends that when necessary the system be thoroughly cleaned prior to the use of a stable inhibitor which does not require continual topping up to combat the effects of hardness, salts and corrosion on the heat exchanger and its associated systems. The Ideal Imax xtra & Imax plus III boilers have an aluminium alloy heat exchanger. Therefore it is important that if water treatment is used it is suitable for Telephone: 0800 389 4670 or Fernox Telephone: 01799 521133 for technical information. 38

Imax Range Open Systems The system should be vented directly off the boiler flow pipe, as close to the boiler as possible. The cold feed entry should be inverted and MUST be positioned between the pump and the vent, and not more than 150mm (6 ) away from the vent connection. There should be a minimum height, 500mm (20 ) of open vent above the cistern water level. The vertical distance between the highest point of the system and the The boiler is at the highest point of the circulation system. Systems designed to raise above the flow tappings will, of course, automatically require a minimum static head higher than shown. given as a guide only. The final position will depend upon particular characteristics of the system. Pumping over of water into the expansion cistern should be avoided. 3000 minimum Feed/expansion cistern Wa ter level (cold) Open vent System return Cold Feed 500mm minimum 3000mm minimum System flow to pump Inverted cold feed entry Cold Feed/Open Vent The independent cold feed and the open vent must comply with Connections to boiler Boiler output (kw) Cold feed Open vent 60-150 1 (25mm) 1 ¼ (32mm) 151-300 1 ¼ (32mm) 1 ½ (38mm) 301-600 1 ½ (38mm) 2 (50mm) must be fitted on the return. This diagram does not show safety valves, water flow switches etc. necessary for the safe operation of the system. Sealed Systems Working pressure 6 bar (87psi) maximum. Subsection 11, Guidance note PM5 Automatically controlled steam and hot water boilers published by the Health and Safety Executive and Water Regulations Guide. Authority, gas or water undertakings. In general, commercial closed pressurised systems are provided with either manual or automatic water make up. In both instances it will be necessary to fit automatic controls intended to protect the boiler circulating system and ancillary equipment by shutting down the Examples of such situations are low water level and operating pressure or excessive pressure within the system. Depending on circumstances, controls will need to be either manually or automatically reset. In the event of shut down, both visual and audible alarms may be necessary. Initial minimum charge pressure should not be less than 0.5 bar (7.2psi) and must take account of static head and specification of the pressurising equipment. When make up water is not provided automatically it will be necessary to fit controls which shut down the plant in the event of the maximum system pressure approaching to within 0.35 bar (5psi) of the safety valve setting. BS 1212 39 Condensing

Commercial Heating Solutions Evomod System requirements - open vented The information and guidance given below is not intended to override any requirements of the above publications or the requirements of the local authority, gas or water undertakings. with the pump manufacturer's minimum requirements, to avoid cavitation. Should these conditions not apply either lower the pump position or raise the cistern above the minimum requirement specified by Ideal Stelrad Group. The isolation valves should be fitted as close to the pump as possible. 1. system flow pipe connection. 2. 3. The maximum flow rate through the boiler is based on a temperature difference of 20 o C at full boiler output. 4. The boiler is at the highest point of circulation in the system. Systems designed to rise above the boiler flow tappings will automatically require a minimum static head higher than that shown. 5. given as a guide only. The final position will depend upon the particular characteristics of the system. Pumping over of water into the expansion cistern must be avoided. 6. Note. This diagram does not show safety valves, safe operation of the system. Open Vent Pipe Sizes Rated output kw Minimum bore mm Nominal Size (DN) in 301 to 600 50 2 601 and above Cold Feed Pipe Sizes Rated output kw Minimum bore mm Nominal Size (DN) in 301 to 600 38 1 ½ 601 and above 50 2 R R 2 ) System requirements - sealed system Working pressure 6 bar maximum. Particular reference should be made to BS. 6644 and Guidance note PM5 "Automatically controlled steam and hot water boilers" published by the Health and Safety Executive. The information and guidance given below is not intended to override any requirements of either of the above publications or the requirements of the local authority, gas or water undertakings. In general commercial closed pressurised systems are provided with either manual or automatic water make up. In both instances it will be necessary to fit automatic controls intended to protect the boiler, circulating system and ancillary equipment by shutting down the boiler plant if a potentially Examples of such situations are low water level and operating pressure or excessive pressure within the system. Depending on circumstances, controls will need to be either manual or automatic reset. In the event of a shutdown both visual and audible alarms may be necessary. charge pressure. Initial minimum charge pressure should not be less than 1.0 bar (14.7psi) and must take account of the static head and specification of the pressurising equipment. The maximum water temperatures permissible at the point of minimum When make up water is not provided automatically it will be necessary to fit controls which shut down the plant in the event of the maximum system pressure approaching to within 0.35bar (5psi) of the safety valve setting. BS. 1212 40

The Ideal Commercial product range Boiler output kw 20 40 100 150 200 600 800 1000 1500 3500 Btu/h (000) 68 136 340 511 682 2047 2729 3412 5118 11942 Atmospheric Boilers Concord CXA/H Concord CXS/H 40-120 40-120 Concord CXSi/H Concord ESi Concord Modular 110-180 140-380 80-720 High Efficiency Boilers Concord Super Series 4 50-600 Concord Super Plus 200-600 Condensing Boilers Evomax 30-150 Evomod 250-1000 Imax plus III Imax xtra 95-330 80-560 Pressure Jet Boilers Buccaneer GTE 21-39 Falcon GTS 40-100 Harrier GTS 105-330 Viceroy GTS 300-780 Viscount GTS Vanguard L 130-3500 754-1450 Approval Ideal Commercial Heating pursues a policy of continuous improvement in design and performance of its products and reserves the right to vary specification without notice. Statutory rights of the consumer are not affected. Please note: The information in this brochure was correct at the time of going to print. Ideal Heating reserve the right to make any modifications to product specifications or any other details, without prior notification. For further clarification, please enquire in writing to the head office address on the reverse of this brochure. 41 Condensing

Ideal Service & Support At Ideal Heating, we are committed towards delivering the highest levels of customer service. With over a century of experience in the heating industry, we know how important confidence and trust is to our customers. partnering with a British manufacturer that s supported by a dedicated national service team, delivering help and advice to you and your customers throughout the year. procedures and manufacturing quality control checks, ensures that all of our products are total comfort and peace of mind. The call centre team, based in Hull, East provide tailored advice. All calls will be answered by trained members of staff who will take ownership of the call. All of our trained staff are on-hand to assist with enquiries or help diagnose and resolve faults over the telephone. Should that not be possible, we will arrange an appointment for one of of engineers are fully trained to exacting standards and are all Gas Safe registered. Ideal Commercial Heating Service Sales Technical Training commercial_services@idealheating.com 42

Style less ordinary Stelrad is the UK s No.1 radiator manufacturer and Europe s favourite radiator brand. Our success has been built on four key commitments: availability, range, reliability and value. www.stelrad.com Telephone: 0870 849 8056

Ideal Commercial Heating Kingston Upon Hull T: 01482 492251 F: 01482 448858 www.idealcommercialheating.com 06.11 203233