INSPECTION REPORT Nr IDD/S-09/922

Similar documents
Declaration of performance ( DoP ) :

GASTEC QA. Approval Requirements 15. for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas. KE 15 January 2012

Inspection and Test Plan for Switchgear

Leadax B.V. Covenant K93792/02. Leadax

EN transition from BS 1387 Structural & Conveyance Business

GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD

NATIONAL TECHNICAL SYSTEMS

GASTEC QA. Approval Requirements 31-2

Slip Resistance Tests on Coated Panels. Duram. for. Date: 4th August Your Reference Number: Document Reference Number:

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment

GASTEC QA. Approval Requirements 136

GASTEC QA. Approval Requirements 69-1

PIP PCTPA001 Testing of Process Analyzer Systems

Pre-shipment Inspection Report

FORM ACCL-PC1 ACCL WITNESS TEST PROCEDURE AND CHECKLIST

GASTEC QA. Approval Requirements 200. for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE)

Technical-Report for SL Lamp 5 W

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

GASTEC QA. Approval Requirements 6

GASTEC QA. Approval Requirements 31-1

Standard Specification for Hardened Steel Washers [Metric] 1

EC Type Examination Certificate

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

At least 10 calendar days prior to project start date Within the last 30 days of a project that will extend beyond 12 months

MGN 453 (M) Maritime and Coastguard Agency Logo MARINE GUIDANCE NOTE

Technical Specification For Design and supply of Water Mist cum CAFS (Compressed Air Foam System) Backpack Fire Fighting System

Test Report. Appliance EMF Testing

FIRE ALARM APPLICATION CITY OF MADISON HEIGHTS

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF PORTABLE FIRE EXTINGUISHER- PERFORMANCE AND CONSTRUCTION AS PER IS 15683: 2006

Aenor Mark Specific Rules for polyethylene compounds (PE) for the manufacturing of pipes for gaseous fuels

STANDARD TECHNICAL SPECIFICATION FOR PRESSURE SWITCH, DIFFERENTIAL PRESSURE SWITCH VOLUME - IIB. SPECIFICATION No: PES

BRL-K774/ Evaluation guideline. for the Kiwa product certificate for Compression fittings to tighten with matching clamping device

Listing Constructional Data Report (CDR)

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

PQS Independent type-testing protocol

Standard Specification for Hardened Steel Washers [Metric] 1

BRL-K14008/ Evaluation guideline. for the Kiwa product certificate for Cartridges to be used for sanitary tapware: Mechanical mixers

SIGMADEK, LTD. FIRE TEST REPORT

GLASS FIBRE REINFORCEMENTS

CE TYPE EXAMINATION CERTIFICATE

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

CEPE guidance to a quality control fire test regime for intumescent coatings Date of issue: 24 May 2011

BUILDING INSPECTION SAFETY PROGRAM MANUAL CHAPTER 5, REFERENCE # 1.4 August 1, 2009 OUT OF SERVICE (OOS) SPRINKLER AND STANDPIPE SYSTEMS

BRL-K618/ Evaluation Guideline. for the Kiwa product certificate for Water meters

AASHTO s National Transportation Product Evaluation Program (NTPEP) Evaluation Program for Plants Producing Geotextiles. Pre-Audit Application Form

Loss Prevention Standard

BRL-K14026/ Evaluation Guideline. for the Kiwa product certificate for Extractable shower hoses for sanitary tapware

for Walmart suppliers. About Bureauu Veritas laboratories in building and Phase 1: Pre- Assessment until the factory Phase 2: Initial Assessment

EN Медь и медные сплавы Бесшовные круглые медные трубы для воды и газа для применения в санитарных целях и отоплении.

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

STANDARD TECHNICAL SPECIFICATION FOR LEVEL SWITCH (FLOAT/DISPALCER TYPE) VOLUME - IIB. SPECIFICATION No: PES

Construction Products Directive

38-SDMS-01 SPECIFICATIONS FOR FAULT INDICATORS FOR UNDERGROUND DISTRIBUTION NETWORKS

Fire Protection Essentials QA/QC Plan Sample

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Impermeable Liner

SPECIAL SPECIFICATION 3687 Impermeable Liner

Electrical test. Determining resistance of conductors by means of using DC four-wire connection measurement

Loss Prevention Standard

BRL-K762. Datum Concept design. Evaluation Guideline. for the Kiwa product certificate for steel pipes for the transport of drinking water

PQS Independent type-testing protocol

Waste fittings for sanitary appliances

CLASSIFICATION Constructional Data Report (CDR)

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

Quick Release mooring Hooks

/Oct/2014 Rev B

Product Specification CAT 6 UNSHIELDED PATCH CORDS

EIA STANDARD TP-38B EIA B. Cable Pull-Out Test Procedure for Electrical Connectors. EIA/ECA B (Revision of EIA A)

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. FCC MPE REPORT

COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER

EC TYPE EXAMINATION CERTIFICATE

Technical Note. Noise emission from Dehumidifier Type C65E TC Project no.: I Page 1 of July 2016

/Mar/2014 Rev A

The Participant will select one of the two Approval Categories (below) and submit the appropriate documentation.

EMC Regulatory Requirements: What you need to know for the EU, EAEU & Australia. Dr Alex Martin

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

Irish Standard I.S. EN :2009

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

CERTIFICATION SAFETY & BEYOND

in accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) ULTRA PROFLEX SP+ES GREY

Part 3: Reference test blocks

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies

File E Project 08ME October 7, 2008 REPORT. UNLISTED COMPONENT - Attachment Plugs, Fuseless. For Use Only In

AUGUST 2016 CONTENTS:

SCHMIDT BRAZED PLATE HEAT EXCHANGERS. ...world leaders in heat transfer technology

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

Technical Data Sheet 3mm Phototransistor T-1

How E+H instrumentation can improve process safety

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

Product catalogue. Hot-rolled small diameter seamless steel tubes

Integrated Process Solutions. Series 46 Heaters HEATER JACKETS FOR STAINLESS STEEL PIPING SIZES 1 1/2 TO 4 (NW 40 TO NW 100)

Vibration tests on a TNAML Luminaire

IECEx Certificate of Conformity

Listing Constructional Data Report (CDR)

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Transcription:

Page: 1/7 PROJECT: TPI For Sheet Pile BV Client: Manufacturer: Nanjing Grand Steel Piling Co., Ltd. Inspection requested by: Ref: P/o nr: (client to BV) P/o nr: GP09111101 (client to Manufacturer) SUPPLY / SUBJECT OF INSPECTION ITEM / TAG Nr QTY (pcs) EN10249 Sheet Pile N.A 346 EN10249 Corner Sheet Pile N.A 2 DOCUMENTS OF REFERENCE : See continuation sheet for additional documents: Yes No Title Reference n Rev. Approved by Date Cold Formed sheet piling of non alloy steels EN10249 EN 1996 INSPECTIONS : Results of inspection : Satisfactory Unsatisfactory Inspection place & Date or Period: No. 9, Shiyang Road, Jiangning District, Nanjing, Jiangsu Province, China & Nov. 12 th, 13 th, 2009 Non Conformities Reports (NCR): N. A NCR s issued during reported period : No Stage of inspection : Before manufacturing During manufacturing Final Packing Kind of inspection: Pre-inspection meeting Witnessing tests Final inspection Document review Expediting & vendor assessment Packing (for details see continuation sheet) List of outstanding NCR s : No Main Conclusions & Remarks: (for details see continuation sheet) Piles listed above were randomly inspected and tested, the results were acceptable. Refer to the inspection details as hereinafter. Next visit scheduled: N/A Stamping : No INSP 002 En 1/7 Copyright Bureau Veritas 09/2006

Page: 2/7 Description of the inspections carried out: Introduction (Attendees, BV scope of work) Third Party Inspection for the sheet piles listed in page 1 was carried out by Mr. David Qiao, the inspector from Bureau Veritas Consulting (Shanghai) Company from Nov. 12 th, 13 th, 2009 at mill s plant, China. Details were as follows: Scope of Inspection Visual Inspection 10% at random; Quantity Check; Dimensional Check 10% at random; Samples taken as per heat no; Documents Review. Applicable Documents & Status of Approval (Type of documents reviewed & endorsed) The inspector reviewed the following documents during the inspection and found the results were acceptable: Raw material certificates Mechanical test and Chemical analysis reports Manufacturing Progress Status The manufacturing for the sheet piles were completed and ready for third party inspection. Details of inspection activities carried out with respect to scope of work. Surveillance with reference to ITP (Each activity elaborated in detail) Visual Inspection The inspector did 10% visual inspection for the surface quality of the sheet piles. During the inspection, one surface dent was found from the corner pile, and then the supplier repaired it by welding and grinding. No other unacceptable defects were found. So the result was acceptable. Please refer the photos for more details. At the same time, the marking was also checked. One label showing the heat no. was found one each pile. So the result was acceptable. And the quantity was also counted by the inspector. The result was acceptable. Dimension Check INSP 002 En 2/7 Copyright Bureau Veritas 09/2006

Page: 3/7 The 10% dimension checking was performed on the sheet piles; the inspector measured the length, width, height and the sheet thickness. The inspection result are as follows: Specification EN10249 Sheet Pile EN10249 Corner Sheet Pile Length Required 20000±50mm 20000±50mm Actual 20000mm 20000mm Width Required 697±2% mm 697±2% mm Actual 690-709 mm 705-711 mm Height Required 265±6 mm 265±6mm Actual 268-269 mm 260-268 Thickness Required 9±6% mm 9±6% mm Straightness Actual 8.88-9.02 mm 8.89-9.05 mm Required 0.25%L 0.25%L Actual 25mm 25mm The results were within the tolerance of the standard. So the results of dimension check were acceptable. Samples Taken and Test in third party s lab a) Chemical composition analysis: one piece per heat. b) Mechanical test Tensile test: 1 piece per heat. Cold bending test: 1 piece per heat The inspector took all the samples in the mill s plant. And all the samples were marked by BV die stamp. And the samples have been sent to the Third Party s lab for the chemical and mechanical test. And the result was acceptable according to EN10248. Please refer the attached Annex 2 Chemical and Mechanical test report. Results of Inspection (incl. calibration status of equipment / instruments used for the inspection / testing) The calibration operation of the instruments used for the inspection/testing was satisfied and acceptable. All testing results were found to be acceptable. Problems pending / Areas of Concern N.A Photos at site INSP 002 En 3/7 Copyright Bureau Veritas 09/2006

Page: 4/7 Visual Inspection Visual Inspection Marking Check Quantity Check Height Check Height Check INSP 002 En 4/7 Copyright Bureau Veritas 09/2006

Page: 5/7 Width check Width check Length check Wall Thickness Check ANNEXES Yes (Total number of pages:2 ) No Inspected by: Checked by: Name: David Qiao Signature: BV STAMP Name: Wei Yue Signature: Date of issue: Nov. 20 th, 2009 Inspection centre: BV SHANGHAI Distribution: CLIENT BV SHA FILE 1 copy INSP 002 En 5/7 Copyright Bureau Veritas 09/2006

Page: 6/7 ANNEXES 1 Pipe batch-quantity-certificate no Pipes Sepcification EN10249 Sheet Pile Heat No. Quantity (Pcs) 134710 55 134916 55 EN10249 Corner Sheet Pile 134711 2 Certificate No. BGTMI0811250006400 BGTMI0811270005000 BGTMI0811250003600 BGTMI0811250006400 134706 44 BGTMI0811280004500 134709 44 BGTMI0811250003800 BGTMI0811250006400 134707 22 BGTMI0811270005000 134917 88 BGTMI0811270005000 134920 11 BGTMI0811270005000 134711 27 BGTMI0811250003800 BGTMI0811250004100 INSP 002 En 6/7 Copyright Bureau Veritas 09/2006

Page: 7/7 Annex 2 Chemical and Mechanical Test Report Grade & Size/mm S390GP &1120*9 S390GP 1120*9 Heat No C S P Si Mn Ni Cr Cu Mo V Al CE Required 0.27 0.050 0.050 0.60 1.70 134710 0.13 0.006 0.016 0.20 0.79 0.005 0.011 0.010 0.001 0.002 0.042 0.27 134916 0.13 0.006 0.013 0.20 0.85 0.007 0.010 0.009 0.001 0.002 0.042 0.28 134706 0.10 0.007 0.013 0.21 0.87 0.006 0.010 0.010 0.001 0.002 0.032 0.25 134709 0.10 0.008 0.020 0.20 0.82 0.010 0.020 0.009 0.001 0.003 0.047 0.24 134707 0.10 0.007 0.019 0.20 0.78 0.006 0.010 0.009 0.001 0.003 0.047 0.23 134917 0.11 0.005 0.013 0.21 0.83 0.005 0.011 0.008 0.001 0.002 0.041 0.25 134920 0.12 0.007 0.013 0.20 0.84 0.006 0.010 0.008 0.001 0.002 0.044 0.26 134711 0.10 0.007 0.019 0.21 0.82 0.006 0.010 0.009 0.001 0.003 0.047 0.24 Heat No. Yield Strength R eh (N/mm 2 ) Tensile Strength R m (N/mm 2 ) Mechanical Test Elongation (%) Bend test (180 0, d=2a)α Required 390 490 20 134710 470 560 30.5 Acceptable 134916 430 530 26.5 Acceptable 134706 410 525 31.5 Acceptable 134709 405 515 34.0 Acceptable 134707 410 510 30.5 Acceptable 134917 430 530 29.0 Acceptable 134920 425 535 30.0 Acceptable 134711 425 520 28.0 Acceptable INSP 002 En 7/7 Copyright Bureau Veritas 09/2006