Bulletin An application for inspection not required Rule 2-005

Similar documents
Please make yourselves familiar with the changes and start implementing them immediately so you can be better prepared for June 30 th, 2018.

Electrical Tech Note 107

Electrical Program. Electrical Laws & Rules. Electrical RCW WAC B. Permits Inspections Access Description Directions Comments.

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

Spring Test 6 due 04/26/2013

TOM BURNS, PLANNING DIRECTOR

Troy's Home Inspection Services LLC

Electrical Safety Program

2011 and 2014 National Electrical Code Changes Residential Only

Dwelling unit feeder/service conductor calculations

ELECTRICAL INSTALLATION PERMIT HOMEOWNER

WIRING AND PROTECTION

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

2009 ELECTRICAL CODE REQUIREMENTS

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

CHAPTER 14 ELECTRICAL CODE

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

Residential Wiring According to the 2011 NEC

Bay Wide Commercial and Home Inspection Thackeray Avenue/ Mail address Hayward, Calif TH AVENUE SAN LEANDRO, CALIFORNIA

CONTINUING EDUCATION FOR OREGON ELECTRICIANS. AMERICAN ELECTRICAL INSTITUTE PO Box Spokane, WA

Inspection Report. Mr. Happy Homeowner. Property Address: Focal Point Home Inspection Ltd.

Portable Generator Safety

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

Building & Safety PERMIT APPLICATION

Inspection Summary. Canyon State Property Inspections 3114 South 98th Street Mesa, AZ (480)

Residential Wiring According to 2011 NEC (Homestudy)

Chapter 1 General... 5

National Electrical Code

CHAPTER 15 PART IV NATIONAL ELECTRICAL CODE, 2017

Electrical Essentials corrected calculation slides only

It should be done through a connection authorization - Should be consistent for all LDCs, to avoid interpretation, public safety risk and liability

ll. Consistency Questions

Axiom Property Inspections

Habitability Guidelines

2017 NEC Presented by: Russ LeBlanc

District 1. 1 Tony Tadysak Craig Mulder

COMMERCIAL PERMIT APPLICATION AND CHECKLIST. Depending on the scope of your project, the following submittal requirements will apply:

breeze easytm model # F100-1W

Inspector FX Field Forms

SDEC 2017 Questions, Group 1

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

Second Revision No. 321 NFPA [ Detail ] Submitter Information Verification. Committee Statement. Make the following changes to 210.

NEC Study Guide CORRECT: C NEC (A)(1)

Residential Wiring (2014 NEC) (Homestudy)

Division of Fire Safety

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

HOME INSPECTION REPORT

Steve Ramsey Home Inspections

Construction Codes Advisory Council

Canadian Property Inspections

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...

RESIDENTIAL OVER. 4. Would it be permissible to hard- wire the dishwasher in question 3? If so, under what conditions?

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

Certificate of Inspection CHECKLIST

TABLE OF CONTENTS. Part I Administrative... 1

Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

Inspector Gadget Homes

Watson Home Inspection Services, LLC.

AFCI. RECEPTACLEFAQs. What is an arc fault? What causes arc faults?

Schedule of Approved Fees

Residential Wiring (2017 NEC) (Homestudy)

TABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19

Mechanical Systems Submittal Guide

This fee schedule is for Building Inspection Fees only.

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

Inspection Report. Inspection Date: 1/1/2011. MultiFamily Sample. Property Address: Street Address. City NJ Zip. All In One Home Inspection LLC

Ceiling Fan Installation Instructions

Excellent Home Inspection Services, LLC

INSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK

THE CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD, NORTH RIDGEVILLE, OHIO TELEPHONE: (440) FAX: (440) Building Department

PROTECTION PLAN CONSUMER GUIDE. Heating + Cooling + Plumbing + Appliance + Electrical. Home protection just got simple.

CADDY CORPORATION. Utility Distribution Systems

FAIRA TRANSPARENCY REPORTS Greenwood Ave N, N304, Seattle, WA March 21, 2018

An examination of electrical fire risks in 16 older houses by Brian Cook (FSR Electrical), March 5, 2014

Revisions for the 2011 National Electrical Code - Part 1

SECTION LIGHTING CONTROLS

Query: Do water heater installations and replacements require a plumbing license, permit, and inspection in the state of Colorado?

EFFECTIVE DECEMBER 28, 2010 SECTION 610 CARBON MONOXIDE ALARMS

SOUTHERN NEVADA PROPOSED AMENDMENTS TO THE 2011 NATIONAL ELECTRICAL CODE

An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010

WIRING FOR APPLIANCES

TECHNICAL ARTICLE. Inspecting Existing Dwelling Electrical Systems Using NFPA 73 by Skip Walker September 2009

Understanding Your Options: AFCI Protection and the 2015 CE Code

Incident Summary (Reference # )

Graded Project. National Electrical Code

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

Inside Out Home Inspections

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

Commercial, Manufacturing and Industrial: Office Areas.18/total sq. ft. Agricultural buildings, detached garages, and accessory.15/total sq. ft.

BUILDING DEPARTMENT FEE SCHEDULE

Pre-Delivery Orientation (PDO)

Smoke Alarm Legislation

Closing Checklist. Mstr Hall/Clo. Mstr Bath. Guest Bath 1/2 Bath Kitchen Nook. Guest Hall. Utility Rm Garage Yard. Right Side Left Side Rear

Hearth and Homes Inspections, llc

Kitchen south wall, living room north and south wall outlets 3. not working properly; no GFCI.

HOME PROTECTION PLAN GUIDE

Inspection Report. Eagle Eye Home Inspectors. John R. Dixon 24GI McKinley Court Princeton, NJ

Exhibit A. Mechnical, Plumbing, and Electrical Plan Check and Inspection Fees. Total Cost Per Unit FEE TYPES MECHANICAL PERMIT FEES

CITY OF DANIA BEACH Local Business Tax Receipt Division 100 W Dania Beach Blvd. Dania Beach, FL Phone: ext 3644 / Fax

Transcription:

Bulletin 2-3-16 An application for inspection not required Rule 2-005 Scope Issued May 2016 Supersedes Bulletin 2-3-15 (1) Rule 2-005 - An application for inspection not required (Basic exemption) (a) Replacement of utilization equipment, receptacles or switches (b) Replacement of luminaires and general use switches (c) Installation of wiring and equipment connected to a Class 2 supply (d) Connection or replacement of appliances (e) Repairs on existing utilization equipment (1) Rule 2-005 - An application for inspection not required (Basic exemption) The definition of utilization equipment has been revised to electrical equipment that utilizes electrical energy for mechanical, chemical, heating, lighting or similar useful purposes. Examples of equipment which do not utilize/consume electrical energy are transformers, capacitors, circuit breakers, etc. All new installations will still require an application for inspection to be filed regardless of the worker designation. Refer to Table B1 summarizing Rule 2-005 (basic exemption) requirements. Electrical Safety Authority Page 1 of 6

Table B1 - An application for inspection not required for specific electrical work in an owner occupied dwelling unit Licensed Electrical Contractor Single Dwelling Unit Owner Original Equipment Manufacturer Installer Fuel Industry Certificate Holder (O.Reg. 215/01 Under TSSA 2000) Plumber authorized under OCAT 2009 Refrigeration & A/C Mechanic authorized under OCAT 2009 Replacement of utilization equipment & receptacles (incl. GFCI receptacles) Note 4 Subrule (a) Replacement of luminaires See Note 5 Replacement of General use switch (incl. dimmer, motion sensor or a timer switch) See Note 5 Wiring and associated equipment connected to the load side of an approved Class 2 power supply Note 6 Subrule (c) Subrule (c) Subrule (d) Subrule (d) Connection or replacement of specific appliances (excluding Air Conditioners) Note 7 Subrule (d) Subrule (d) Subrule (e) Subrule (e) Subrule (e) Repairs on existing installed utilization equipment Note 8 Meter-base Plug-in Transfer Device Subrule (e) Subrule (f) Subrule (e) Bonding of interior metal gas piping or tubing Subrule (g) Notes: 1. All equipment must be approved in accordance with Rule 2-024. 2. The basic exemption does not include installing, extending, altering or repairing of any electrical wiring. An application for inspection will be required to be filed. 3. As per Trade certification regulations, each worker can only perform work that is within his/her designation. 4. Refer to Rule 2-005(a). The equipment being replaced must be installed in the same location and interchangeable with one being replaced, is not supplied by a branch circuit exceeding 30 A and 130 V, does not include work in a service box or panelboard, and any installation within the scope of Sections 24, 38, 64, 68 and 84. 5. Refer to Rule 2-005(b). The equipment being replaced must be installed in the same location, interchangeable with one being replaced and installed in a branch circuit not exceeding 15 A and 130 V. This exemption is limited Electrical Safety Authority Page 2 of 6

for single dwelling unit owners. For home owners replacing a luminaire or switch, the work does not include recessed lighting, aluminum or ungrounded wiring such as knob and tube, or work within Section 68. High-rise condominiums are not to be considered as a single dwelling unit therefore will require an application for inspection to be filed. 6. Refer to Rule 2-005(c). The installation does not include electrical equipment identified in Subrule 2-022(3), or any installation within the scope of Sections 68 and 32. 7. Refer to Rule 2-005(d). Appliances include dishwashers, cook tops, garburators, trash compactors, ovens, exhaust fans, baseboard heaters, furnaces and hot water tanks installed in an existing branch circuit not exceeding 30 A and 240 V. Replacing furnaces/boilers includes all associated equipment such as condensate pumps, humidifiers and air cleaners connected on the load side of the furnace disconnect switch. 8. Refer to Rule 2-005(e). The repair does not include equipment installed on a branch circuit exceeding 30 A and 130 V, or 50 A and 240 V, any repair work that invalidates the original certification mark, or that alters the equipment electrical rating or characteristics. Also, the repair does not include detaching any electrical wiring connected to that equipment. (a) Replacement of utilization equipment, receptacles or switches in a dwelling unit Rule 2-005(a) Question 1 Does replacing of a circuit breaker in an electrical panel require an application for inspection? Answer 1 Yes. Subrule (a)(vii) does not exempt replacement of a breaker in a service box or panelboard. An application for inspection is required to be filed. Question 2 Is replacing a duplex receptacle with a Ground Fault Circuit Interrupter (GFCI) Class A receptacle exempted from an application for inspection if the work is done by a LEC? Answer 2 Yes. A receptacle is defined as one or more female contact devices on the same yoke installed at an outlet for the connection of one or more attachment plugs. A GFCI receptacle Class A is a ground fault circuit interrupter that will interrupt the circuit to the load within a predetermined time and a specific ground fault current. The replacement is not considered as a like for like application as stated in Subrule (a)(iii), The replacement is permitted without filing an application for inspection provided the work is performed by a LEC. Question 3 Can a LEC replace utilization equipment (such as hot water tank) in a dwelling unit (such as a rental condo, time share unit or apartments) which is not occupied by the owner without application for inspection? Answer 3 No. The exemption indicated in Subrule (a)(i) only applies to an owner occupied dwelling unit and will require the LEC to file an application for inspection. Rule 2-005 does not apply to dwelling units where the units are intended to be rented to the public, or exchanged to others, on a short term basis or other structures not included in the definition of dwelling unit. Question 4 Does the replacement of receptacles or general-use switches connected to knob and tube, un-grounded cables or aluminum wiring in an owner occupied dwelling unit require an application for inspection? Electrical Safety Authority Page 3 of 6

Answer 4 No, provided the work is performed by a LEC as per Subrule (a). The following shall be included in the scope of work in relation to Subrule (a): Replacement of the existing receptacles with GFCI receptacles as part of knob and tube or ungrounded branch circuits inside residential installations. For more information refer to the Flash notice, Knob and tube wiring in residential installations. Replacement of existing receptacles or general-use switches in residential homes connected to aluminum branch circuit wiring will require: o the device to be approved and marked for copper and aluminum conductors only. Note: devices with push-on terminations shall not be used with aluminum wiring. o installing copper pigtails using approved wire connectors marked for copper to aluminum connections. For more information refer to the Flash notice, Aluminum wiring in residential installations. (b) Replacement of luminaires and general use switches in a single dwelling unit Rule 2-005(b) Question 5 Does the basic exemption include replacing a surface mounted luminaire with a recessed luminaire if a LEC performs the work? Answer 5 No. Replacing a surface mounted luminaire with a recessed luminaire is not considered as a like for like installation i.e. interchangeable as stated in (iii) and will require the LEC to file an application for inspection. Question 6 Can a home owner replace an existing surface mounted luminaire with a recessed luminaire in their single dwelling unit without filing an application for inspection? Answer 6 No. ( iii) does not allow replacing the existing luminaire with a recessed luminaire unless an application for inspection is filed. Question 7 Can a single dwelling owner replace a general-use switch with a dimmer, timer or a motion sensor light switch in his/her own single dwelling without filing an application for inspection? Answer 7 Yes. allows the single dwelling owner to replace the general-use switch without filing an application for inspection. Question 8 Does the basic exemption in allow an occupant leasing a single dwelling to replace a luminaire or general-use switch without filing an application for inspection? Answer 8 No. does not include the occupant leasing the single dwelling to replace a luminaire or general-use switch without filing an application. Note: The occupant may perform the work in accordance with Ontario Regulation 570/05 (Licensing Of Electrical Contractors and Master Electricians) but will be required to file an application for inspection. Question 9 Is an owner of a duplex dwelling unit who occupies one unit and rents out the other dwelling unit allowed to replace a general-use switch or luminaire in the rental unit without application for inspection? Answer 9 No. (i) only applies to the owner occupying their dwelling unit. Electrical Safety Authority Page 4 of 6

Note: The owner is allowed to perform the work in accordance to Ontario Regulation 570/05, but will be required to obtain an application for inspection since he/she does not occupy the rental unit. Question 10 Is an owner who occupies a dwelling unit in a high-rise condominium allowed to replace a general-use switch or luminaire without application for inspection? Answer 10 No. only applies to a single dwelling. The definition of a single dwelling does not include multi units such as a high- rise condominium. Notes: 1. The owner is allowed to perform the work in accordance to Ontario Regulation 570/05, but will be required to obtain an application for inspection 2. Condominium rules may not allow electrical work to be performed unless authorized by the Condominium Corporation. (c) Installation of wiring and equipment connected to a Class 2 power supply in a dwelling unit Rule 2-005(c) Question 11 Does a LEC require an application for inspection when replacing the wiring for a door chime connected to the load side of a Class 2 power supply? Answer 11 No. Subrule (c) allows the installation of the wiring as long as the power supply does not exceed 42.4 V and 100 VA. (d) Connection or replacement of appliances in a dwelling unit Rule 2-005(d) Question 12 Can a professional who holds a fuel industry certificate extend, replace or install a branch circuit when replacing a furnace? Answer 12 No. The installation of a branch circuit is required to be installed by a LEC since the wiring falls outside the scope of the fuel industry certificate license. Subrule (d)(iv) does not include installing, extending, altering or repairing the wiring connected to the equipment. Question 13 Can a person holding a refrigeration and air conditioning license (air conditioner mechanic) replace an air conditioning unit without an application for inspection? Answer 13 No. An air conditioning unit is not an appliance exempted in Subrule (d). An application for inspection is required to be filed. Electrical Safety Authority Page 5 of 6

(e) Repairs on existing utilization equipment in a dwelling unit Rule 2-005(e) Question 14 Does Rule 2-005(e) allow the detaching of the wiring of the utilization equipment when performing a repair on the equipment? Answer 14 No. Subrule (e)(iii) does not include detaching of electrical wiring to the equipment. The exemption only allows the repair of the utilization equipment. Removing and replacing the equipment will require an application for inspection to be filed (except for work performed on appliances listed and in compliance with in Subrule (d)). Electrical Safety Authority Page 6 of 6