The Eco Hot Water heat pump The EMMETI heating pumps have a square form factor for better installation in all spaces. To install the device you only need to link the intake and exit water tubes, the condensation dump and the home electric system. The EQ 2014 and EQ 3014 ES water pumps take the heat from the surrounding air and cede it to the water inside the tank, reducing costs for heating of water which means a great economic saving, up to 70% in comparison with traditional electric water heaters. Moreover, the Eco Hot Water heating pump, coupled with the FEBOS accessory (not included), can be remotely activated through smartphone/tablet; free app downloadable from the pple Store and Google Play. The Range EQ 3014 ES EQ 2014 L B C D E F G 54 db 1020 983 936 kwh/annum GJ/annum B C D E F G XL EQ 3014 ES 57 db 1393 54 db 1345 1283 kwh/annum GJ/annum 2015 812/2013 57 db EQ 2014 2015 812/2013 Model EQ 2014 EQ 3014 ES Tank capacity 200 l 300 l verage heating capacity 1,8 kw 1,8 kw
Constructional characteristics EQ 2014 model Capacity 200 liters. S235 JR steel boiler with internal inorganic coating. EQ 3014 ES model Capacity 300 liters. ISI 316-L stainless steel boiler with internal pickling coating. Exchanger for solar integration with a surface of 1 m 2. Both models Insulation in rigid polyurethane foam (PU) of high thickness and without CFC and HCFC, average thickness 50 mm. nticorrosion electronic anode (2 on model EQ 3014 ES). External painted sheet metal with epoxy powders (silver gray color). Hydraulic fittings placed on the left side. 1.5 kw 230 V~ electric heater integration. Manually activable through control panel or automatically as heating pump integration or anti-legionella treatment. R134a ecological refrigerant fluid. Rotary compressor for the maximum quiet operation. Centrifugal fan. Condenser wrapped around the steel boiler (not immersed in the water). Touch screen control panel, backlit to allow the different working parameters settings within 24 hours. TEMP Energy saving gets Economic saving On the basis of the European data it is clear that the annual energy consumption for domestic hot water production of an average family composed by 3 persons is equal to 1.840 kwh/year. Electric heat pump heaters EQ 2014 EQ 3014 ES EQ 3014 ES + Thermal solar EQ 2014 - EQ 3014 ES + Emmeti Sun + + Electrical energy consumption 1840 kwh/year 620 kwh/year 320 kwh/year 0 kwh/year nnual energy cost 408 /year 136 /year 70 /year 0 /year NB: Data refer to the following conditions: annual average temperature of the inlet air equal to 20 C - Electricity cost 0.22 /kwh
Installation example for EQ 2014 with FEBOS accessory Photovoltaic Fotovoltaico Rete Electrical elettrica network FEBOS Inverter Main Contatore Exchange Meter di scambio (ENEL) Contatore Generation di produzione Meter (GSE) (GSE) Ingresso Inlet aria air Uscita Outlet air aria 2 3 Outlet Uscita sanitary acqua calda hot sanitaria water Ingresso Inlet acqua cold water fredda Works with iphone EPE pipe Ø internal 160 mm 2 PVC pipe Ø 160 mm 3 Tee BS with diverter valve - Ø internal 160 mm
Installation example for EQ 3014 ES with FEBOS accessory Photovoltaic Electrical network FEBOS Inverter Main Exchange Meter (ENEL) Generation Meter (GSE) Inlet air Outlet air Solare Thermal termico solar 2 3 Outlet sanitary hot water Condenser Inlet cold water Solar exchanger Insulation Works with iphone EPE pipe Ø internal 160 mm 2 PVC pipe Ø 160 mm 3 Tee BS with diverter valve - Ø internal 160 mm
Technical Data Model EQ 2014 EQ 3014 ES Nominal power consumption by compressor W 460 460 Installation with heat source: Indoor air DB 20 C ( Outdoor air DB 7 C ), according the Regulations EU n 812-814/2013 and Standard EN 16147:2011 Declared load profile L XL Energy efficiency class (*) + (+*) Thermostat temperature setting C 55 55 Heating up time h:min 5:15 (6:45*) 7:15 (11:15*) Heating up energy input kwh 2,55 (3,05*) 3,50 (4,90*) Total energy consumption during tapping cycle WEL-TC kwh 4,29 (4,68*) 5,79 (6,30*) COPDHW 2,71 (2,49*) 3,29 (3,03*) Standby power input W 36 32 Maximum volume of usable hot water (40 C) l 239 343 Sound power level LW, indoors db() 59 (54*) 59 (54*) Sound power level LW, outdoors -(57*) -(57*) Refrigerant load R134a / CO 2 eq. (GWP = 1430) kg / t 0,95 / 1,36 0,95 / 1,36 Max working pressure refrigerant circuit (HP/LP) Mpa 2,1 / 1,3 2,1 / 1,3 Power supply V~ / Hz 230V~ 50Hz 230V~ 50Hz Maximum power consumption W 2050 2050 Maximum current consumption 8,92 8,92 N. of electrical heaters x power consumption W 1 x 1500 1 x 1500 ir flow m 3 /h 400 400 Static pressure Pa 40 40 Storage capacity l 200 300 Water fittings Ø G 3/4" F G 3/4" F Max working pressure bar 7 7 Dimensions (WxDxH) mm 590x565x1750 664x642x1820 Grade of protection IPX1B IPX1B Dimensions of air connections (Ø / max length) mm/m 160 / 10 160 / 10 Weight (net / with water) kg 115 / 315 122 / 422 * Outdoor air DB 7 C Working range Model EQ 2014 EQ 3014 ES Inlet air temperature -5 43 C -5 43 C Water temperature (heat pump) 9 60 C 9 60 C Installation room temperature 5 35 C 5 35 C Minimum volume of room installation 30 m 3 30 m 3
Components and dimensions Model EQ 2014 Inlet air Outlet air 590 1730 190 575 220 884 420 1050 950 370 380 150 590 16,5 92,5 275 460 80 Model EQ 3014 ES Inlet air Outlet air 664 1804 733 563 253 1112 962 16,5 733 107,5 563 370 353 253 410 190 642 290 150 664 1 uxiliary electric heater 1.5 kw B Electronic anode protection C Storage water discharge D Inlet sanitary cold water E Output sanitary hot water F Condensation discharge G Safety valve pressure & temperature (P&T) H Inlet for solar panel I Output for solar panel J Inlet water recirculation K Inlet air Ø 160 mm L Outlet air Ø 160 mm M Passage of electric cables N Control panel
ccessories (supplied separately) EPE gray pipe Internal Ø 160 mm L = 2 m Elbow 90 EPE gray Internal Ø 160 mm Elbow 45 EPE gray Internal Ø 160 mm BS black tee int. Ø 160 mm with diverter valve PP coupling for EPE pipe Internal Ø 160 mm PP fixing collar for EPE pipe Internal Ø 160 mm Wall-mounted external grids assembly for air inlet and outlet, including springs and chains 230 V - 30 active energy meter for DIN 1M tracks PVC ivory pipe Ø 160 mm L = 1 m FEBOS, Single-phase and Three-phase versions (*) (*) To use with single-phase heat pump and three-phase electrical system Tablet touchscreen 7 Operating System ndroid Respect the environment! For a correct disposal, the different materials must be divided and collected according to the regulations in force. Emmeti copyright ll rights are reserved. This publication nor any of its contents can be reproduced or publicized without Emmeti s written authorization. The data contained in this publication are subject to change in every time, for technical and commercial requirements. Emmeti are not responsible for eventual errors or inexactitudes. Rev. - 09.2017 - Ufficio Pubblicità & Immagine - BT EMMETI spa - Via Brigata Osoppo, 166-33074 Vigonovo frazione di Fontanafredda (PN) - Italia Tel. 0434.567911 - Fax 0434.567901 - www.emmeti.com - info@emmeti.com 9900595800001