Item No. Part No. B B B B B B B B B0 B B0 B0 B Front panel assy. Case/Left Case/Right Power switch Fuse/0V-A Fuse/0V-A Fuse/0V-A HEAD OFFICE TEL:+--- FAX:+--- http://www.hakko.com E-mail:sales@hakko.com 00V 0V 0V 0V 0V 0V 00-0V 0V 0-0V Please access to the following address for the other Sales affiliates. http://www.hakko.com 00-0 HAKKO Corporation. All Rights Reserved. Item No. Part No. B B B B B B B B0 B0 B B B Power cord, -wire cord & American plug Power cord, -wire cord but no plug Power cord, -wire cord & BS plug Power cord, -wire cord & European plug Power cord, -wire cord & BS plug Power cord, -wire cord & Chinese plug Power cord, -wire cord & Australian plug Power cord, -wire cord & American plug Power cord, -wire cord & SI plug Power cord, -wire cord & BR plug Control card Connecting cable 0V USA India 0V KTL 0V CE 0V CE China 0. MA0XZ00
HAKKO FM-0 Item No.,, Part No. FM0-0 FM0-0 B B B B B Conversion kit Connector assembly Connector cover Tip B00 Heat resistant pad is yellow Yellow Orange Blue Green See back page: 'TIP STYLES' Iron Holder Item No. Part No. - FH00-0 Iron holder With B Iron Holder Parts Item No. Part No. B00 B B B B B0 B B-0-0 Iron receptacle Tip fixing spring Holder for iron receptacle Iron holder base Cleaner base Stay Switch case assembly Tip cleaner Cleaning wire With screws Tip tray Item No. Part No. B Tip tray. PARAMETER SETTINGS The HAKKO FX- comes from the factory with the following values preset. Temperature scale Power save Low temperature alarm setting Resetting the supervisor or operator control setting Setting temperature Buzzer setting (C-E sound, S-E sound) Buzzer setting (Set temperature alert) Fahrenheit 0 min. 00 F 0 0 F ON ON The HAKKO FX- has the following six parameters: ) C or F temperature display selection ) Power save ) Low temperature alarm setting ) Resetting the supervisor/operator control setting ) Buzzer setting (C-E sound, S-E sound) ) Buzzer setting (Set temperature alert) Once the station enters parameter mode, set the parameters in the order shown below. After all the parameters have been set, normal operation will be resumed. Entering the parameter C or F temperature display. Turn power OFF.. Insert the control card into the card slot in the front of the unit.. Press and hold down the and buttons simultaneously, and then turn power ON.. Hold and buttons down until the display shows (Celsius) or (Fahrenheit). When either the display shows either or, the station is in parameter input mode. Pressing either the and button will cause the display to alternate between or. When the desired scale is displayed, select by pressing the sequence to power save mode. button. The system will automatically
Power save setting Set the time from the placement of the soldering iron on the iron holder to the activation of the sleep function. NOTE: When not using the power save function, do not connect the iron holder and the soldering station with the connecting cable. Power save example: 0 Sleep (immediately after the soldering iron is placed on the iron holder) 0 Sleep (0 minutes after the soldering iron is placed on the iron holder) 0 Auto-power shutoff (0 minutes after the soldering iron is placed on the iron holder) NOTE: The power save time can be set in steps of one minute (0 minutes max.) When the sleep function is activated, the temperature of the tip begins to drop. When the display shows, pressing any button When the station enters the parameter input mode, the procedure is as follows. (0 times). (0 times). button button button once. button once. button once. The power save function works immediately after the soldering iron is placed on the iron holder. When 0 minutes have elapsed since the soldering iron was placed on the iron holder, the temperature drops to 00 C/00 F automatically and the station enters the power save mode. When 0 minutes have elapsed since the soldering iron was placed on the iron holder, power to the heater will be automatically shut off (auto power shutoff). the power will be turned on again. NOTE: The sleep function does not work in case the setting temperature is less than 00 C/0 F. When the auto-power shutoff function is activated and power to the heater is shut off, the buzzer sounds three times. When the display shows, and to begin soldering, cycle the power switch OFF, then ON. Resetting the low temperature alarm tolerance setting The unique function alerts the operator when the sensed temperature drops below a set limit. Should this occur, an error message will be displayed, and the buzzer will sound continuously. When the temperature returns within the allowable range, the buzzer will stop. Range of allowable low temperature alarm tolerance for : 0-0 for : 0-00. When the station enters low-temperature alarm tolerance setting mode, the hundreds digit begins flashing. Enter and store the value in the same manner as described in Changing the temperature setting.. If you enter a value exceeding the allowable range shown to the left, you will be brought back to entering a value in the hundreds digit. If this occurs, reenter a correct value.. Once the value is stored, the system will automatically sequence to resetting the supervisor/operator control setting mode. Example: When the setting temperature is 0 C and the low temperature alarm tolerance is 00 C, buzzer will sound when the tip temperature will drop over 0 C.. Resetting the supervisor/operator control setteing To change the supervisor/operator control settings, the procedure is as follows. The display will show or when this mode is entered. : No offset value can be entered without inserting the card. : An offset value can be entered without inserting the card. Pressing the or button will change and. When the desired setting is displayed, select by pressing button.. Buzzer setting (C-E sound, S-E sound) In the buzzer sound setteing mode, which sets whether to sound the buzzer when a sensor error or soldering iron error occurs, or is displayed. : The buzzer does not sound. : The buzzer sound Select or and press the button.. Buzzer setting (Set temperature alert) In the buzzer sound setteing mode, which sets whether to sound the buzzer when a sensor error or soldering iron error occurs, or is displayed. : The buzzer does not sound. : The buzzer sound Select or and press the button. The system will exit the parameter setting mode and begin heater control. It is now ready for normal operation.
. CHECKING PROCEDURE FM-0 FM-0. ERROR MESSAGES Sensor Error Low-temperature alarm tolerance error EXAMPLE: 0 C (00 C 0 C) Set temperature Low-temperature alarm tolerance OR F (0 F 00 F) Set temperature Low-temperature alarm tolerance Heater terminal short-circuit error When there is the possibility that a failure has occurred in the sensor or heater (including the sensor circuit), is displayed and the power is shut down. CAUTION The sensor error also occurs if the tip is not inserted properly. If the sensor temperature falls below the difference between the current temperature setting and the low-temperature alarm tolerance, is displayed and the warning buzzer sounds. When the tip temperature rises to a value within the set tolerance, the buzzer will stop sounding. EXAMPLE: Assume that the temperature setting is 00 C/0 F and the tolerance 0 C/00 F. If the temperature continues to decrease and finally falls below the value indicated below while the heating element is on, the displayed value starts blinking to indicate that the tip temperature has dropped. will flash, and the buzzer will sound continuously, when the tip is inserted wrong way round, an incompatible tip is inserted, or a foreign object has found its way into the connector. Soldering iron error will be displayed if the connector cord is not attached to the station OR the wrong soldering iron is connected.
. TIP STYLES ø. (ø0.) (.) (.) Unit: mm (in.) T-B SHAPE-B T-B SHAPE-0.B T-B SHAPE-0.B T-B SHAPE-0.B T-BL SHAPE-BL SHAPE B R0.. (0.0) T-BLL SHAPE-BL LONG R0. (R0.0) 0 (0.) R0. (R0.0) (0.0) R0. (R0.0) (0.0) R0. (0.) R0. (0.) T-BC SHAPE-BC T-BCF* T-BC SHAPE-BC T-BCF* T-BC SHAPE-BC T-BCF* T-BC SHAPE-.BC T-BC SHAPE-.BC ø (ø0.0) ø ø (ø0.) ø. (ø0.0) ø. SHAPE BC SHAPE C. (0.0). (0.) T-BC SHAPE-.BC ø. (ø0.).. (0.) T-C SHAPE-C ø (ø0.0). (0.) 0 (0.) T-CF* SHAPE-C ø. (0.0) (0.) T-CF* SHAPE-C ø (ø0.). (0.0) ø (ø0.) (0.) T-C SHAPE-C T-CF*. (0.). (0.) (0.0) (0.) (0.) (0.) (0.). (0.) T-D0 SHAPE-0.D T-D SHAPE-.D T-D SHAPE-.D T-D SHAPE-D T-D SHAPE-.D ø0. (ø0.0) ø. (ø0.0) ø. ø ø. (ø0.0) 0. (0.0). (0.) 0. (0.0) (0.) 0 (0.) 0. (0.0). (0.) 0 (0.) 0.. (0.0) (0.0) (0.0) 0. (0.0) (0.) 0 (0.) T-D SHAPE-.D T-D SHAPE-D T-D SHAPE-.D T-DL SHAPE-.D LONG T-DL SHAPE-D LONG SHAPE D ø. (ø0.) 0.. (0.0) (0.0) (0.0) ø (ø0.) 0. (0.0) (0.). (0.) ø. (ø0.0). (0.0) (0.) (0.) ø. (ø0.) 0. (0.0) (0.) 0 (0.) ø (ø0.) (0.0). (0.) (0.) T-DL SHAPE-.D LONG T-XD SHAPE-.XD ø. (ø0.0) ø.. (0.0) (0.) (0.) 0. (0.0) (0.) T-I SHAPE-I T-IL SHAPE-IL T-ILS SHAPE-ILS SHAPE I R0. R0.. (0.0) R0. (R0.00). (0.) SHAPE J 0 T-J0 SHAPE-0.J R0.. (0.) (0.) 0 T-JD SHAPE-.JD 0. (0.0) ø. (0.) (0.) 0 T-JD SHAPE-.JD ø. (0.). (0.). (0.) 0 T-JL0 SHAPE-0.JL R0.. (0.0). 0 T-JS0 SHAPE-0.JS R0.. (0.0). (0.) R0. (R0.0) 0. (0.0)
. TIP STYLES T-K SHAPE-K T-KF SHAPE-KF T-KL SHAPE-KL T-KU SHAPE-KU SHAPE K ø. (ø0.) (0.) ø. (ø0.) (0.) ø. (ø0.). (0.0) (0.) ø (ø0.). (0.0) (0.) T-R0 SHAPE-.0R T-R SHAPE-.R T-R SHAPE-.R T-R SHAPE-.R T-R SHAPE-.R SHAPE R ø. (ø0.).0.. (0.0) (0.0). (0.0) ø. (ø0.). (0.0).. (0.0) (0.0). (0.). (0.). (0.) (0.0) ø. (ø0.). (0.).. (0.0) (0.0). (0.) ø. (ø0.). (0.).. (0.0) (0.0). (0.) SHAPE SB T-SB0 R0. T-SBS0 SHAPE-0.SB. (0.) (0.) SHAPE-0.SBS. (0.) T-SB0 R0. SHAPE-0.SB. (0.). (R0.0)(0.) T-SBS0 SHAPE-0.SBS (0.) T-SB0 R0. (R0.0) SHAPE-0.SB. (0.0) 0. (0.) T-SB0 R0. (R0.0) SHAPE-0.SB 0. (0.) T-SBC0 SHAPE-0.SBC 0. ø0. (ø0.0) (0.0) (0.) R0. (R0.0) (0.) R0. (R0.0) (0.) T-00** TUNNEL. x. T-00** TUNNEL. x 0. T-00** TUNNEL x. T-00** TUNNEL x. T-00** TUNNEL x.. (0.). (0.0).. (0.) (0.0). (0.). (0.). (0.0) 0.. (0.) (0.0). (0.). (0.).. (0.) (0.). (0.). (0.).. (0.) (0.). (0.). (0.).. (0.) (0.). (0.) TUNNEL T-00** TUNNEL. x. T-00** TUNNEL. x. T-00** TUNNEL x 0. T-00** TUNNEL. x 0. T-00** TUNNEL x. (0.). (0.).. (0.) (0.0). (0.).. (0.).. (0.) (0.). (0.) 0. (0.) (0.) 0. (0.0) (0.) (0.). (0.). (0.) 0. (0.). (0.) (0.) 0. (0.) (0.) (0.) (0.) (0.) T-0** QUAD. x. T-0** QUAD 0. x 0. T-0** QUAD. x. T-0** QUAD. x. T-0** QUAD. x. QUAD. (0.). (0.). (0.). (0.). (0.) T-0** QUAD. x. 0. (0.). (0.) 0. (0.). (0.). (0.) T-0** QUAD. x.. (0.0) (0.). (0.0) (0.). (0.) T-0** QUAD. x.. (0.0) (0.). (0.0) (0.) (0.) T-0** QUAD. x.. (0.). (0.). (0.). (0.). (0.) T-0** QUAD. x.. (0.). (0.). (0.). (0.0). (0.). (0.). (0.). (0.). (0.). (0.). (0.) (0.). (0.) (0.) (0.). (0.). (0.). (0.). (0.). (0.). (0.). (0.). (0.0) (0.) (0.) T-0** SPATULA 0. T-0** SPATULA. T-0** SPATULA. T-0** SPATULA 0 SPATULA 0. (0.). (0.). (0.). (0.). (0.). (0.) 0 (.). (0.) 0. (0.) SPECIAL APPLICA- TIONS TYPE T-0** SHAPE-.MM LONG REACH CHISEL ø.. (0.0) (0.) (0.) 0 T-0** SHAPE-LONG REACH BENT CHISEL (0.0) (0.) (0.) (0.) T-BCM SHAPE-BC Bevel with indent**. 0. (0.0). (0.0) ø. (0.) T-BCM SHAPE-BC Bevel with indent**. (0.).. (0.) ø (ø0.) 0 (0.) R0. (R0.0) * Tinned on the soldering surface only. ** The iron tips marked with double asterisks (**) have a temperature accuracy of ± C (±F), when used with the default offset. Others have a temperature accuracy of ± C (± F), when used with the default offset.