CERTIFICATE OF APPROVAL No CF 391 UNION ARCHITECTURAL HARDWARE

Similar documents
CERTIFICATE OF APPROVAL No CF 5263 KCC ARCHITECTURAL

CERTIFICATE OF APPROVAL No CF 118 DORMA UK LTD

CERTIFICATE OF APPROVAL No CF 738 ALLEGION (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 388. Allegion (UK) LTD

CERTIFICATE OF APPROVAL No CF 114 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

CERTIFICATE OF APPROVAL No CF 145 GEZE UK LIMITED

CERTIFICATE OF APPROVAL No CF 5507 CONSORT ARCHITECTURAL HARDWARE LTD

CERTIFICATE OF APPROVAL No CF 5657 UNION ARCHITECTURAL HARDWARE

CERTIFICATE OF APPROVAL No CF 5038 FREEMAN & PARDOE T/A ARROW ARCHITECTURAL

CERTIFICATE OF APPROVAL No CF 252 GEZE UK LIMITED

CERTIFICATE OF APPROVAL No CF 117 DORMA UK LTD

CERTIFICATE OF APPROVAL No CF 5530 TALLERES DE ESCORIAZA S.A.U.

CERTIFICATE OF APPROVAL No CF 494 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 5350 TAIWAN DAEDALUS DOOR CONTROL CO. LTD

CERTIFICATE OF APPROVAL No CF 5118 ASSA ABLOY LTD

CERTIFICATE OF APPROVAL No CF 392 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 5516 ALLGOOD PLC

CERTIFICATE OF APPROVAL No CF 388 INGERSOLL RAND SECURITY TECHNOLOGIES - BRITON

CERTIFICATE OF APPROVAL No CF 646 EUROSPEC ARCHITECTURAL HARDWARE LIMITED

CERTIFICATE OF APPROVAL No CF 689 BOSS DOOR CONTROLS

CERTIFICATE OF APPROVAL No CF 5494 ASSA ABLOY AB

CERTIFICATE OF APPROVAL No CF 5075 EXIDOR LIMITED

CERTIFICATE OF APPROVAL No CF 5506 ALLEGION (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 5542 ASSA ABLOY SECURITY SOLUTIONS

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED

TECHNICA DORMA. Controlled. d Door Closing. Closerss. appended hereto:

CERTIFICATE OF APPROVAL No CF 267. DORMA UK LIMITED Wilbury Way, Hitchin, Hertfordshire SG4 0AB Tel: Fax:

CERTIFICATE OF APPROVAL No CF 5527 TALLERES DE ESCORIAZA S.A.U.

CERTIFICATE OF APPROVAL No CF 111 INGERSOLL RAND SECURITY TECHNOLOGIES - BRITON

CERTIFICATE OF APPROVAL No CF 810 HOPPE (UK) LIMITED

CERTIFICATE OF APPROVAL No CF 850 ZOO HARDWARE LIMITED

CERTIFICATE OF APPROVAL No CF 145 GEZE LIMITED

CERTIFICATE OF APPROVAL No CF 530 HOPPE (UK) LIMITED

F O C U S D O O R C L O S E R S

CERTIFICATE OF APPROVAL No CF 520 ASSA ABLOY LTD T/A ASSA ABLOY SECURITY DOORS

Easy-action Door Closer DORMA TS83

CERTIFICATE OF APPROVAL No CF 5179 LORIENT POLYPRODUCTS LIMITED

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

CERTIFICATE OF APPROVAL No CF 418 PROMAT UK LTD

CERTIFICATE OF APPROVAL No CF 136

CERTIFICATE OF APPROVAL No CF 5635 P3 SRL

CERTIFICATE OF APPROVAL No CF 5236 EMVER PAINTS INDUSTRIES LLC

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges

Updated to. include Declaration of Performance Certificates WHICH DOOR CONTROL? Meeting the requirements of the Equality Act & Fire regulations

Meeting the requirements of the Equality Act & Fire regulations. Which Door Control?

CERTIFICATE OF APPROVAL No ME 5085

fire doors the burning issues From specification to maintenance the life cycle of a fire door explained guide

25 th November Title:

BWF-Certifire Fire Doors and Doorsets. Best Practice Guide

Regulatory Reform (Fire Safety) Order 2005

Strebord 35 FD30 Strebord 44 FD30 Strebord 54 FD60

BWF-Certifire Fire Doors and Doorsets. Best Practice Guide

DORMA. Free Swing and Hold-open Solutions for Fire Doors. An alternative to Fire door keep shut

Fire doors are a lifeline. When properly fitted and properly cared for they give vital minutes for people to safely escape from fire and smoke.

Maintenance. Why Maintain Fire Doors? Regulations

The Association for Specialist Fire Protection

Newstar Door Closing Devices & Accessories

Cl/SfB (32.5) Xt7 (K2) Acoustic, Smoke and Fire Seals for Door Assemblies

Code of Practice: Hardware for Fire and Escape Doors. Issue No.2 June 2006 THE GUILD OF ARCHITECTURAL IRONMONGERS

Section 2 - Applications - General. Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames

C/S Fire Rated Door Edge Protection Product Range FD60

Cl/SfB (32.5) Ro8 (K2) Fire Resistant Glazing Systems

A Guide to the Selection of Smoke Seals for Doorsets. Information Sheet No. 5. Intumescent Fire Seals Association

Practice Guidee No.1. of the

Product Guide. The highest possible standards. The best possible solutions. Manufactured in the UK. Cert No 5893 ISO 9001

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

Guide to the use of Smoke Seals in Doorsets

30 Minute Firedoor. 30 minute firedoor

Code of Practice: Hardware for Fire and Escape Doors

The new way to replace Briton door closers and keep your existing door fire safe.

Agrément Certificate 92/2841 website: Product Sheet 1

Guide to Fire and Escape Doors: Part 1 - What are they? Produced by the Guild of Architectural Ironmongers Sponsored by Abloy UK

Guidance Note No 19/1. CE Marking windows and doorsets

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

BS 476: Part 6: 1989+A1:2009

Product. Regulations. Agrément Certificate No 92/2841 Third issue* Designated by Government to issue European Technical Approvals

Best practice guide. Door coordinator devices to BS EN in association with. Association of Building Hardware Manufacturers

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

Introduction of MSBC Secure India Pvt Ltd. Manufacturer & Installer of Fire Resistance Timber Doorsets

Hardware for Sliding Doors & Folding Doors

Fire Door Maintenance Guide.

Guide to interpreting Markings for Single Axis Fire Doors Hinges

BS 476: Part 6: 1989+A1:2009

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Panic and Emergency Exit Devices

Best practice guide. Electrically powered hold-open devices to BS EN in association with. Association of Building Hardware Manufacturers

best practice guide BS EN 14846: 2008 Electromechanically operated locks & striking plates to in association with

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

Controlled Door Closing Devices

Managing Fire Safety in your building: Fire Doors Inspections. Part of the KCC Architectural Group

MECHANICAL FIRE STOPPING SOLUTIONS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

The DDA Explained ARROW ARCHITECTURAL

FIRE SAFETY MANAGEMENT PROTOCOL FIRE DOORS & FIRE DOOR ASSEMBLIES

EN 1155:1997 TESTS OF : PERKO R106 FS CONCEALED FIXED ELECTRICALLY POWERED FREE SWING DEVICES FOR SWING DOORS. Leopold Street, Birmingham.

Loss Prevention Standard

Loss Prevention Standard

Transcription:

CERTIFICATE OF APPROVAL No CF 391 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of School Street, Willenhall, West Midlands WV13 3DU Tel: 01902 364625 Fax: 01902 603523 Have been assessed against the requirements of the Technical Schedule(s) denoted below and are approved for use subject to the conditions appended hereto: CERTIFIED PRODUCT UNION J-N8834 Overhead Door Closing Device TECHNICAL SCHEDULE TS34 The Contribution of Controlled Door Closing Devices and Accessories to Fire Resisting Doorsets Signed and sealed for and on behalf of Exova (UK) Limited trading as Warrington Certification Paul Duggan Certification Manager Page 1 of 5

1. The UNION J-N8834 is an overhead mounted door closing device complying with EN 1154. This approval relates to the following overhead mounted door closing devices and configurations: Projecting arm (Fig. 1) Link-arms Projecting arm (Fig. 61) Body Parallel arm (Fig. 6) Body Slide arms Body J-N8834 Key: - approved - Not approved Note: Where alternative arms for non-fire applications are included within the packaging, the use of these components on fire resisting door assemblies will invalidate the certification. 2. This certification is designed to demonstrate compliance of the product or system specifically with Approved Document B (England and Wales), Section D of the Technical Standards (Scotland), Technical Booklet E (N. Ireland). If compliance is required to other regulatory or guidance documents there may be additional considerations or conflict to be taken into account. 3. This approval relates to its use with the following door assemblies:- Latched and unlatched, intumescent sealed door assemblies consisting of timber faced and edged leaves with timber, cellulosic or mineral cores in timber frames having a fire resistance up to 120 minutes (Code ITT). The closer is approved on the basis of: i) Initial type testing to EN1154 and BS EN 1634-1. ii) An appraisal against TS34 iii) Inspection of quality management system iv) Inspection and surveillance of factory production control v) Ongoing audit testing in accordance with EN 1154 requirements 4. The closers shall be fixed with screws supplied by the closer manufacturer. Bolt-through fixings shall not be used. Page 2 of 5 Signed

5. Where the closers are fitted to door leaves or frames that are manufactured from mineral composite-based materials, or low-density cellulosic- based material, the door assembly shall have previously been shown capable of accommodating the installation of closers at the head of the doorset, without detriment to the door assembly s performance. 6. This approval is applicable only to the specified closers when mounted in the applications stated above and under the classification codes section of this certificate and used with door assemblies of proven fire resistance (as defined in BS EN 1634-1 or BS 476: Part 22: 1987) and having power ratings appropriate to the leaf sizes subject to a minimum size 3 (as specified in BS EN 1154). 7. The approval relates to on-going production. The product and/or its immediate packaging are identified with the manufacturer s name, the product name or number, the CERTIFIRE name or name and mark, together with the CERTIFIRE certificate number and application where appropriate. Page 3 of 5 Signed

8. The following tables show acceptable doorset types and fire resistance periods: Key: Approved Door Type Class MM IMM ITT ITM ITC FD20 FD30 FD60 FD120 FD240 E 20 EI 20 E 30 EI 30 E 60 EI 60 E 90 EI 90 E 120 EI 120 E 240 EI 240 - approved - Not approved Page 4 of 5 Signed

OVERHEAD DOOR CLOSER MODELS 9151A, 9156A, 9161, 9166, 9451 and 9461 9. Doors are classified as the following types: Type IMM - 20 minute to 240 minute doorsets that consist of metallic leaves in metallic frames that contain intumescent materials in the frame to leaf gap. Type ITT - 20 minute to 120 minute doorsets containing intumescent seals and consisting of non-metallic faced and edged leaves hung in timber frames Type ITM - 20 minute to 120 minute doorsets containing intumescent seals and consisting of non-metallic faced and edged leaves hung in metal frames. Type ITC - 20 minute to 120 minute doorsets containing intumescent seals and consisting of non-metallic faced and edged leaves hung in proprietary composite frames, of which the principal material is other than timber or metal but which may include any other materials. Scope of Approval: Doors may not include uninsulated glass above 20% of their total area. All closer models are only approved in the fitting applications detailed with their classification codes. The closer may not be fitted to timber doorsets without leaf/frame edge intumescent protection. Mechanical Hold open option is not approved. Classification code The above approval provides the following classifications: UNION J-N8834 4 8 Further Information 3 4 1 1 3 Further information regarding the details contained in this data sheet may be obtained from UNION Architectural Hardware (Tel: 01902 364625). Further information regarding CERTIFIRE certification and other approved products can be obtained from CERTIFIRE (Tel: 01925 646777). Page 5 of 5 Signed