BANGALORE ELECTRICITYSUPPLY COMP. LIMITED (Wholly owned by Government of Karnataka Undertaking) OFFICIAL MEMORANDUM

Similar documents
Particulars 415V Class :>3A, OOA,160A, 200A & 250A TP Moulded Case Circuit Breakers (AHFrame)

Em-powering the nation!!!

SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD., CIRCLE OFFICE, BHOPAL PART B : PRICE BID

Consumer guidelines for availing Grid connectivity of Solar Rooftop PV systems in HESCOM (on net-metering basis)

SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD.

VERIFICATION OF FIRE ALARM SYSTEMS

Commercial Waste. Rules and Regulations

BUREAU OF ENERGY EFFICIENCY

(Wholly owned Government of Karnataka. (f>' J+.

FIRE FIGHTER II APPLICATION PENNSYLVANIA VOLUNTARY FIRE SERVICE CERTIFICATION PROGRAM NFPA Edition

SUB: Circulation of integrated seniority list of UDC (HR) of MSETCL as on

DEPARTMENT OF FIRE & EMERGENCY SERVICES DNH.

Key Personnel. CORPORATE PROFILE! Introduction! OUR PRODUCTS! DG AMF and Automatic Synchronising panels

KTDC HOTELS & RESORTS LIMITED MASCOT SQUARE, TRIVANDRUM - 33

DC INDUSTRIAL PLANT SERVICES

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate.

STANDARD TECHNICAL SPECIFICATION FOR LEVEL SWITCH (FLOAT/DISPALCER TYPE) VOLUME - IIB. SPECIFICATION No: PES

Purchase: (Fire Fighting) May 26, Sub: Quotation for AMC of Fire Fighting Systems

(date) except for the departures, if any, detailed as follows: Name (CAPITALS) N/A. Name (CAPITALS) N/A

GATEWAY BUILDING ELEVATOR AND ESCALATOR SERVICES

NOTICE INVITING TENDER

Velammal Engineering College Department of Civil Engineering

STANDARD TECHNICAL SPECIFICATION FOR PRESSURE SWITCH, DIFFERENTIAL PRESSURE SWITCH VOLUME - IIB. SPECIFICATION No: PES

EMPANELMENT DOCUMENT NOTICE FOR EMPANELMENT OF SUPPLIERS AND SERVICE PROVIDERS.

Regency Hampstead API. at Hayes Road. a space for.. ..every mood.. crafted by. Pride in Excellence since 1988

LAUNDRY AND DRY CLEANING

Taking Action on Fire and Life Safety

PRE-QUALIFICATION OF FIRE SAFETY AUDITORS

TOUBRO LIMITED ELECTRICAL & ELECTRONICS DIVISION - ELECTRONIC PRODUCTS 510(K) SUMMARY. (Per section )

CORPORATION OF THE CITY OF KINGSTON. Ontario. By-Law Number A By-Law To Impose Fees For Automatic Alarms (False) False Alarm By-law

COMPANY PROFILE Electrical & Instrumentation Contractor

February 23, Skanray Technologies Private Limited Yolanda Smith, Consultant Smith Associates 1468 Harwell Ave Crofton, Maryland 21114

TENDER DOCUMENT FOR SUPPLY OF EPOXY MIXING & POURING PLANT

SOLAR POWER PLANT AUTOMATIO

KS PARK ELECTRICALS COMPANY PROFILE

INTERNAL COMMISSION FOR CONTRACTS A WARD.f- UNIVERSITY OF DSCHANG (UDs) ******************* OPEN NATIONAL CALL FOR TENDERS

DISTRICT OF PORT HARDY BYLAW A BYLAW TO ESTABLISH AND REGULATE THE DISTRICT OF PORT HARDY FIRE DEPARTMENT

Test Report issued under the responsibility of:

Co.

FIXED ASSETS. Drafe-&Scull. QHSE Manual FIXED ASSETS. DocumentName: QHSE Ref. No. IMS/CS/FAl03Rev. 01. Date: 16thMarch Rev Date Revision Record

THE SCHOOL BOARD OF SARASOTA COUNTY, FLORIDA MEMORANDUM

Creating a Comprehensive Physical Security System

AS/NZS :2009. Performance of household electrical appliances Refrigerating appliances AS/NZS :2009

WESTERN ZONAL OFFICE ENGINEERING DEPTT. WEST WING, FIRST FLOOR, "YOGEKSHEMA, NARIMAN POINT MUMBAI

Title: Fire Sprinkler System Permit Requirements

Table of Contents. Consolidated Version, revised and verified January 24, (Original) August 21, 2017

THE CORPORATION OF THE CITY OF BELLEVILLE BY-LAW NUMBER BEING A BY-LAW TO ESTABLISH AND REGULATE A FIRE DEPARTMENT AND EMERGENCY SERVICES

The Corporation of the City of Kenora. By-law Number

Thomasville Municipal Code Chapter 12 PUBLIC SAFETY

Intention to Designate under Part IV, Section 29 of the Ontario Heritage Act 844 Don Mills Road and 1150 Eglinton Avenue East

RISK ASSESSMENT, DISASTER MANAGEMENT AND SAFETY MEASURES (ONSITE & OFFSITE)

Automation Access Control

Household and similar electrical appliances Safety

Chapter ALARM SYSTEMS

Underwood Heater Installation Manual

New School Construction: Safe School Opening. OAR and IOR Joint Training February 17, 2005

MEMORANDUM. Pat Black, CPPB, Director of Materials Management APPROVAL TO AWARD BID #7095 FOR PLUMBING SERVICES TIME AND MATERIALS

soc_09may BANK OF BARODA DETAILS OF CONTRACTS CONCLUDED DURING THE MONTH OF MAY 2009 Last date of BCC Estate Management

INTRODUCTION TAQQAT Global Co. Abdulla Fouad Group

5 Eireann Quay Site Plan Control Application

Updated 04/07/2017 Page 1/8

BYLAW NO (CONSOLIDATED)

We, Newtech Trading Corporation, are ISO 9001:2008 certified importer, Supplier, Trader &

ORDINANCE NO, 5907 AN ORDINANCE AMENDING ALBANY MUNICIPAL CODE CHAPTER , UNIFORM FIRE CODE

Chapter 16 FIRE PREVENTION AND PROTECTION* Article I. In General. Article II. Fire Department. Article III. Hazardous Material Emergencies

CITY OF KELOWNA MEMORANDUM. Date: June 20, 2001 File No.: Z City Manager Planning and Development Services Department

NATIONAL BANKING GROUP WEST-1

Australian/New Zealand Standard

THE CORPORATION OF THE VILLAGE OF FRUITVALE BY-LAW NO. 749

TOTAL OF GROUP A ESTIMATE PROPOSED AIR CONDITIONING WORKS FOR STATE BANK OF IND. SR. Description QTY UNIT GROUP A AIRCONDITIONING

IND: MFF - North Karnataka Urban Sector Investment Program - Tranche 2

District of Sicamous. Fire Department Bylaw No. 126, Effective Date February 26, 1996

Unitech Scales And Measurements Pvt. Ltd

ORBITTAL GROUP. ORBITTAL Electromech Engineering Projects Pvt. Ltd. ORBITTAL Panels. Your Reliable Partner ISO 9001:2008 COMPANY

INDUSTRIAL EXTENSION BUREAU

Green Electricals Pvt. Ltd.

Specification of (COC) Automatic Open Cup Flash Point Tester with accessories

Overview of standardization and mandatory technical regulation systems of Turkmenistan. (gas and electricity)

AWARDED CONTRACTS BASED ON PNOC S 2015 and 2016 APP (covering transactions from November 16, 2015 to November 15, 2016)

Queries raised by the representatives. 4 Sl. No.( iv) 31 Refer Sl. No. 2 It should be Windows 10 professional as it is the latest one

National conference on pumps 20th November,09-Coimbatore. Creati ng connecti ons

Application for Registration of Fire Protection Consultant on Record

Credit Suisse AG RULEBOOK OF THE ORGANIZED TRADING SYSTEM INTERNAL MARKET MAKING. 01 September 2018

COMMERCIAL PLAN SUBMITTAL CHECK LIST Mercantile / Business / Educational / Storage / Factory Industrial / Hazardous / Institutional

DETAILS OF CONTRACTS CONCLUDED DURING THE MONTH OF "JANUARY" 2018 ABOVE THRESHOLD LIMIT

PMFY-P20VBM-E. City Multi Indoor Product Information. Indoor Unit

Suzuki Motorcycle India Pvt. Ltd., Gurgaon

AS/NZS :2009

BULLETIN BU/EL Revised August 11, 2015

Code of Practice // For the installation, inspection and testing of electrical installations tel/fax:

DumpsValid. Download a free sample of any of our exam questions and answers

Electrical Safety Policy

DEPARTMENT OF PUBLIC SAFETY. Division of Fire Prevention and Control 8 CCR

CITY OF VAUGHAN EXTRACT FROM COUNCIL MEETING MINUTES OF SEPTEMBER 26, 2017

38-SDMS-01 SPECIFICATIONS FOR FAULT INDICATORS FOR UNDERGROUND DISTRIBUTION NETWORKS

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

'+8 ===========================================================

IRRAD - PHASE II RADIANT COOLING - DESIGNING FOR FLEXIBLE PARTITION OF SPACE

BANK OF BARODA BARODA CORPORATE CENTRE MUMBAI

SINGLE-PHASE STANDARD

Transcription:

BANGALORE ELECTRICITYSUPPLY COMP. LIMITED (Wholly owned by Government of Karnataka Undertaking) Telephone 080-22342121. Fax 080-22342128. E-Mail gmgs.work@gmail.com No: GM(QS&SjDGM(EI. )-3)IBC-IIIF-852114_151 CYS-50 Enc!: OFFICIAL MEMORANDUM 010 GM( S&S) Office Corporat Office, K.R. Circle B~a1ore 56() 001 Date: c)_ - 1>-( ~ Sub: Vendor approval for supply of BEE 3 Star Rated 63 conventional type Distribution Transformers of M/s Kama Transformers Pvt Ltd., Bangalore. Ref: CPRI/I&P/6/ 1/BESCOM/2014 dated: 14.07.2014 ****** 3' Approval is hereby accorded to M/s Kamath Transformers Ltd.,No:A-155, 3rd cross, 1st stage, Peenya Industrial Estate, Bangalore-560 058 as approv d vendor for supply of BEE 3 Star Rated 63kVA and 250KVA conventional type Distribu on Transformers to prospective consumers in BESCOM area for Electrification of layouts, Mis. Buildings, Action plan works, Turnkey works / Partial Turnkey works etc., I S1. Period ofv alidity upto 63kVA BEE 3 Star Rated Distribution Transformers, 1. 50Hz, ONAN Cooled, complete with first filling EHV 31.03.201~ (Subject to Grade Transformer Oil with all accessories and revalidation every year) confinnin_gto latest versions of IS - 1180 & IS - 2026 2. 250kVA Conventional type Distribution Transformers, 50Hz, ONAN Cooled, complete with first filling EHV Grade Transformer Oil with 31.12.20H (Subject to all accessories and confirming to latest versions revalidatioi every year) of IS - 1180 & IS - 2026 The approval is subject to the following conditions:- I 1. The prospective consumers who purchase the BEE 3 Star Rated &3kVA and 250KV A conventional type Distribution Transformers shall stand guarantee for the materials for a period of one year. 2. The materials shall confirm to the specification as prescribed in the relevant IS/IEC & its amendment from time to time. 3. The BEE 3 Star Rated 63kVA and 250KV A conventional type Distribution Transformers shall be got inspected by (QS&S) or the concerned jurisdictional Engineers, BESCOM before they are put into service. 4. BESCOM reserves the right to withdraw the approval issued, in case of any violation of the approved drawing and specification at any time. Copy to- Approved by Director (Technical) ~~\"" (G.~Vela) General Manager (El.) QS&S,BES OM, Bangalore. 1. The Chief General Manager (El.,) CA / Operations, BESCOM, Bang 2. All the Chief Engineer (Electy.,) O&M ZONES, BESCOM. 3. The General Managers (Ele.,) Procurement /Projects / DAS, BESCO. 4. All the Superintending Engineers (Ele), O&M circles, BESCOM, 5. All the Executive Engineers (Ele.) O&M Divisions, BESCOM. 6. All the Assistant Executive Engineers (Ele.) O&M Sub-Divisions, BE VendorO.M 103

7. PS to D(T) to place it before Hon'ble Director (Technical), BESeOM. 8. Mis Kamath Transformers Pvt Ltd.,No:A-155,3rd cross, 1st stage, Peenya Industrial Estate, Bangalore-560 058. 9. Officecopy I M.F. VenclorO.M 104

fi BANGALORE ELECTRICITY SUPPLY CO ~ (Wholly owned by Government of Karnataka Underta l'e-repfo~ 080-22342121, Fax 080-22342128, % M(QS&S)Office E-Mail gmqs!@.bescom.co.in.j Co orate Office, K.R. Circle No: GM(QS&SJDGM(EI.,J-3JIBC-llIJ4-J51/C"l S :-4% Ban alore-560 001 Encl: Dat~: I ~ - g -~olj..t OFFICIAL MEMORANDUM I ' Sub: Vendor approval for supply of BEE 3 Star Rated 25kYA, 63kVA, 100kVA and 250kVA Conventional Distribution Transformers qf M/s Cauvery Power controls, Bangalore. I Ref: CPRl/I&P/6/1/BESCOM/2014 Dated 17.07.2014. ****** Approval is hereby accorded to M/s Cauvery Power control, y No: 32/2, Chennaiah Badavane, Anibescent School road, Gollarahatti, Magadi Main Ro d, Vishwaneedam Post, Bangalore-560 091 as approved vendor for supply of the following B E 3 Star Rated 25kVA, 63kVA, 100kVA and 250 kva Conventional Distribution Tran formers to prospective consumers in BESCOM area for Electrification of layouts, M S Buildings, Action plan works, Turnkey works / Partial Turnkey works etc., S1. 1. 2. 3. 4....1 25kVA BEE 3 Star Rated Distribution Transformers, 50 ~z, ONAN Cooled, complete with first filling EHV Gra de Transformer 'Oil with all accessories and confirming to latest versions of IS - 1180 & IS - 2026. 63kVA BEE 3 Star Rated Distribution Transformers, 50tiz, ONAN Cooled, complete with first filling EHV Grade Transformer Oil with all accessories and confirming to latest versions of IS - 1180 & IS - 2026 100kVA BEE-3 Star Rated Distribution Transformers, 50 Hz, ONAN Cooled, complete with first filling EHV Grs de Transformer Oil with all accessories and confirming to latest versions of IS - 1180 & IS - 2026 250kVA Conventional type Distribution Transformers, 50 Hz, ONAN Cooled, complete with first filling EHV Grs de Transformer Oil with all accessories and confirming to latest versions of IS - 1180 & IS - 2026 The approval is subject to the following conditions:- Period of validity upto 30.12.2018 (Subject to Re Validatation every year) 30.04.2018 (Subject to Re Validatation every year) 1. The prospective consumers who purchase the BEE 3 Sta Rated 25kVA, 63kVA, 100kVA and 250 kva Conventional Distribution Transformers shall stand guarantee for the materials for a period of one year. 2. The materials shall confirm to the specification as prescribed in the relevant IS/IEC & Its amendment from time to time. I 3. The BEE 3 Star Rated 25kVA, 63kVA, 100kVA and :250 kva Conventional Distribution Transformers shall be got inspected by (Q~&S) or the concerned jurisdictional Engineers, BESCOM before they are put into service. 4. BESCOM reserves the right to withdraw the approval issue,in case of any violation of the approved drawing and specification at any time. (i(.wr,\\m ---*1Qw\~----'---..-- (G. sheela) Ge eral Manager (E1.) Quali,Standard and Safety, B SCOM, Bangalore. VendorO.M 140

Copy to- 1. All the Chief Engineer (Electy.,) O&MZONES, BESCOM. 2. The Chief General Manager CAjOperations, BESCOM,Bangalore 3. 4. The General Managers (Ele.,) Procurement j Projects & DAS, BESCOM. The Superintending Engineer(Ele), C O&MCircles,BESCOM 5. All Executive Engineer (Ele.) O&MDivisions, BESCOM. 6. DGM-1j2j3j4,QS&S,BESCOM & DGM-CTAZ,QS&S,BESCOM 7. 8. AllAssistant Executive Engineer (Ele.) C O&MDivisions, BESCOM PS to D(T)to place it before D(T),BESCOM,Bangalore. 9. Mis Cauvery Power control, Sy No: 32/2, Chennaiah Badavane, Anibescent School Road, Gollarahatti, Magadi Main Road, Vishwaneedam Post, Bangalore-560 091 10. Officecopy j M.F VendorO.M 141

_ BANGALORE ELECTRICITY SUPPLY COMPANY LIMITED ~ (Wholly owned by Government of Karnataka Undertaking~ COM % GM(QS&S) Offiee Telephone 080-22342121, Fax 080-22342128, Corporate Office, K.R. Circle E-Mail gmqs.work@gmail.com Bangalote-560 001 No: GM(QS&S)DGM(EI.,)-3)1BC-llIF-852114-15ICYS- 41 Date: 'b { s J I U Enel: OFFICIAL MEMORANDUM Sub: Vendor approval for supply of 11kV 250kVA conveptional Distribution Transformers of MI s Vijay Electric Co., Bangalore. I Ref: CPRI/I&P/61 1/BESCOM/2014 dated: 19.05.2014! ****** Approval is hereby accorded to Mis Vijay Electric Co., No: 22-2~, 12th cross, Vyshnavi Nagar, Babasabpalya, Kengeri, Bangalore-60 as approved vendor for ~upply of the following 11kV 250kVA conventional Distribution Transformers to prospective rnsumers in BESCOM area for Electrification of layouts, M.S. Buildings, Action plan works, rnkey works I Partial Turnkey works etc., I 81. 250kVA Conventional type Distribution Transformers, 50Hz, ONAN Cooled, complete 1. with first filling EHV Grade Transformer Oil with all accessories and confirming to latest versions of IS - 1180 & IS - 2026 Period pf validityupto 30.06.2p19 (Subject to revalidation every year) The approval is subject to the following conditions:- 1. The prospective consumers who purchase the 11kV 250kV A conventional Distribution Transformers shall stand guarantee for the materials for a period of one year. 2. The materials shall confirm to the specification as prescribed in the relevant IS/IEC & its amendment from time to time. i 3. The 11kV 250kVA conventional Distribution Transformers shall be got inspected by (QS&S) or the concerned jurisdictional Engineers, BESCOM before they are put into service. 4. BESCOM reserves the right to withdraw the approval issued, inlcase of any violation of the approved drawing and specification at any time. l, Approved by Director (Technical) I ~{~~. ~! I! ~~v' [G. h ela) General Manager (El.) QS&S, J3ESCOM, Bangalore.! Copy to- 1. The Chief General Manager (El.,) CA I Operations, BESCOM, Bangalore 2. All the Chief Engineer (Electy.,) O&M ZONES, BESCOM. : 3. The General Managers (Ele.,) Procurement /Projects I DAS, BE:j>COM. 4. All the Superintending Engineers (Ele), O&M circles, BESCOM.! 5. All Executive Engineers (Ele.) O&M Divisions, BESCOM. 6. - All Assistant Executive Engineers (Ele.) O&M Sub-Divisions, B~COM 7. PS to D(T) to place it before Hon'ble Director (Technical), BES~lf~' 8. Mis Vijay Electric Co., No: 22-26, 12th cross, Vyshnavi Nagar, Babasabpalya, Kengeri, Bangalore-60. 9. Office copy I M.F. VcndorO.M 102

B BANGALOREELECTRICITYSUPPLYCOMP.. LIMITED - - (Wholly owned by Government of Karnataka Undertaking) fe?epfw"'ite 080-22342121, Fax 080-22342128, % GM( 8&8)Omce E-Mail gmqs.work@gmail.com Corporat Office, K.R. Circle No: GM(Q,S&S)DGM-3IBC-llIF-852114-1 C'IS -htb Bangalor~-560001 Encl: Date: Q5 ~O~ -\~ OFFICIAL MEMORANDUM Sub: Vendor approval for supply of B/9mtrs RCC Pole & Bmtr PCC poles Ref: CPRI/I & P/ 6/1/BESCOM/ 2014 dated 14,07.2 14. ******* Approval is hereby accorded to M/s Maruthi Cement Ud og, KlADB,Plot No: 49, II phase, Antrasanahalli, Tumkur-572 106 as approved v ndor for supply of B/9intrs RCC Poles & Bmtr PCC poles to prospective consumers f1 BESCOM area for Electrification of layouts, M.S. Buildings, Action plan works, Tuqkey works / Partial Turnkey works & Self Execution works etc.,. S1. I Period of validity up to Bmtr/ 115kgf & 9mtr / 145kgf- 1. RCC Poles & BMtr/140kgf 31.01.2019 (subject to Reval dation every year). PCC Poles The approval is subject to the followmgconditions... - _;_ " Approved 1. The prospective consumers who purchase the 8/9mtrs CC Poles & 8mtr PCC poles shall stand guarantee for the materials for a eriod of one year from the date of COmmissioning. 2. The materials shall confirm to the specification as prescri ed in the relevant IS/IEC/BESCOM & its amendments from time to time. j 3. The 8/9mtrs RCC Poles & 8mtr PCC poles shall be got inspected by (QS&S) or the concerned jurisdictional Engineers, BESCOM befort they are put into 4. ~~~~~M reserves the right to withdraw the approval issjed, in case of any violation of the approved Drawing and Specification at any ~e.. by Director (Technical) i~1m (d~e~~) Genenal Manager (E1.) Copy to- QS&S, B SCOM, Bangalore. 1. All the Chief Engineer (Electy.,) C,O&M ZONES, BESCOM. 2. The Chief General Manager (Operations)/CA,Corporate office, BESCOM, B 3. The General Managers (Ele.,) Procurement I Projects & DAS, BESCOM. 4. All the Superintending Engineers (Ele), C,O&M Circles, BESCOM. 5. All Executive Engineers (Ele.) C,O&M Divisions, BESCOM. 6. PS to D(T) to place it before D(T), BESCOM, Bangalore. 7. The Manager (El.,) Q,S&S, Corporate office, BESCOM. 8. 9. Mis Maruthi Cement Udyog, KlADB, Plot No: 49, II phase, Antrasanahalli, Office copy I M.F mkur-572 106