Water Mist Fire Suppression

Similar documents
I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Safer. Smarter. Tyco. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker.

AESTHETIC SPRINKLERS.

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

Simple On The Outside...

Making equipment decisions

FIRE PROTECTION, NATURALLY AQUASONIC Water-Atomizing Fire Suppression System

WATER MIST CONVENTION AND EXHIBITION

The Science Behind Water Mist Protection of Typical Building Hazards

What is HI-FOG? The natural enemy of fire

Sprinkler Solutions for Storage Applications

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

FIGHTING FIRE as easy as blowing out a match

Machinery Space Fire Protection System from an Approved Product Portfolio

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

Fire protection for buildings

What provides highly reliable fire protection?

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Performance Based Fire Protection With Water Mist

Solutions at every turn.

AQUAMIST Mist Control Center (MCC) Pump Skid Unit. General Description. Technical Data. Page 1 of 8 JANUARY 2016 TFP2270. Worldwide Contacts

STORAGE FIRE PROTECTION SPRINKLERS

PHIREX AUSTRALIA. FOGEX & MISTEX WATER MIST FIRE PROTECTION

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

How can you minimize consequential damages in case of a fire?

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

High flying fire protection HI-FOG for aircraft hangars

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

The metering orifice is sized according to the type and percentage of concentrate used and is also secured with a stainless steel retaining ring)

Tyco Fire Valves Pure Performance

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

ODS & SGG Alternatives for the Fire Protection Industry 2018

Rick Seidel Fike Corporation Regional Sales Manager

FOREFRONT AT THE OF PROTECTION

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

FIRE SUPPRESSION SYSTEM

Connected: Global protection, all together

TECHNICAL NOTES. Literature Review on Hybrid Fire Suppression Systems. Peter Raia Michael J. Gollner University of Maryland

Ensuring safe passage HI-FOG for underground stations

Superior by Design The Kidde ADS TM FM-200 System

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

Worldwide Contacts.

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Water Mist System. Principle of Water mist evolves from combination of 3 main effects:

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

The History of IWMA. 18th International Water Mist Conference will (IWMC) take place in London on 19th & 20th September 2018

PREVENT SYSTEMS WHEN SAFETY IS TAKEN SERIOUSLY

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

What extinguishes fires without pressure peaks?

Emergency shutdown systems. Procedures for bypassing ESD s

Report on First Revision November 2013 NFPA 750

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

Submittal Packages Detailed with Items and Reviewers

Jonathan Redding Area Sales Manager FOGTEC Fire Protection Cologne, Germany

High-pressure water mist systems and fire testing. Max Lakkonen IFAB Institute for Applied Fire Safety Research

Foam Products ENGLISH

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

The Next Generation of Foam Fire Suppression. Automatic CAF Fire hose reel system FEATURES

Global Marine Solutions and Services From Ship to Shore Single Source Providers for Fire, Security, Life Safety

MINIMAX FIRE PRODUCTS WHITE PAPER THE COST-BENEFIT ADVANTAGES OF REPLACING HALON WITH 725 PSI MX 1230 CLEAN AGENT FIRE SUPPRESSION SYSTEMS

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System

Sinorix Silent Extinguishing Technology protecting the quiet way

MORE THAN JUST FIRE PROTECTION

HFC-227ea FIRE SUPPRESSION SYSTEM

Fixed fire protection solutions

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Gulf Industrial Systems Co. Fire, Safety & Security Systems

automatic FiReFighTing SYSTeMS in PainT booths

Shalaby Institute of Fire Protection Heyrothsberge, Germany.

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

Fire suppression systems for server rooms and data centres

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

XC10 combined fire detection and extinguishing control

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

FIRE PROTECTION SYSTEM FOR INDUSTRIAL KITCHENS

Watermist Systems. Versatile, Affordable Water Mist Fire Suppression. your TRUSTED partner in fire safety

AUTOMATIC FIREFIGHTING SYSTEMS IN KITCHENS

MORE THAN JUST FIRE PROTECTION

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

SECTION FM-200 FIRE SUPPRESSION SYSTEM

XC10 combined fire detection and extinguishing control

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Fire Protection Products Technical Data Book Table of Contents, August 2017

Transcription:

Water Mist Fire Suppression How less water has a big impact.

HELPING PROTECT YOUR BUSINESS AND VALUED ASSETS WITH WATER MIST FIRE PROTECTION SYSTEM INTRODUCTION Many buildings have specific areas that could benefit from using a water mist system. These systems use less water than traditional sprinkler systems, causing less damage to high-value assets. This white paper provides a general overview of water mist technology, the types of water mist systems currently on the market and what to look for when specifying a water mist system. HOW FIRE OCCURS In order to understand how water mist systems work, we need to understand how fires occur. Four things must be present at the same time in order to produce fire: fuel, heat, oxygen and a chemical reaction. The first three elements are frequently referred to as the Fire Triangle. Adding the fourth element (chemical reaction) will result in the Fire Tetrahedron. Removal of any one of these elements will result in fire extinguishment and the disruption or weakening of one of these elements will result in fire control or suppression. Essentially, water mist takes away one or more elements of the Fire Triangle or Tetrahedron. HOW DOES WATER MIST WORK? Water mist systems can control fire by reducing heat, displacing oxygen and controlling the fuel source by wetting and cooling the surrounding fuel surfaces. The key to water mist technology lies in the design of the nozzle along with established pressure criteria to create a mist of small water droplets. Water mist systems will have droplet sizes where 99% of the volumetric diameter is less than 1mm. Smaller droplets absorb heat at a faster rate than larger droplets due to the higher surface area-to-mass ratio. A volume of water that consists of smaller droplets has a comparatively larger cumulative surface area than the same volume of water made up of larger droplets such as those from a standard spray sprinkler. As a result, a rapid absorption of heat and evaporation of the smallest droplets will occur, causing temperatures to decrease while oxygen is displaced. When the water droplets absorb enough heat, they evaporate, rapidly creating steam. Due to this vaporization, oxygen will be displaced in the area of the fire, disrupting the Fire Tetrahedron. Small water droplets tend to remain suspended in the air and fill the entire space. The result being that any air the fire draws in becomes saturated with these droplets and vaporization occurs. Water mist also helps to pre-wet and block the transfer of radiant heat to the adjacent combustibles, reducing the risk of fire to spread and grow. TYPES OF WATER MIST SYSTEMS There are three main categories of water mist systems: low pressure (175 psi or less), intermediate pressure (175 psi-500 psi) and high pressure (500 psi or greater). Within these categories you may have single-fluid systems (water only) or twin-fluid systems (water and an atomizing medium like nitrogen). All these system types are tested and approved for a variety of fire hazards and should be handled as an engineered water mist system, each requiring specific design and calculation criteria. An example of a low to intermediate pressure water mist system is the AquaMist Ultra Low Flow (ULF) which operates at working pressures up to 250 psi (17.2 bar). The AquaMist FOG, which is a high-pressure system, operates at working pressures of 1015 psi to 2900 psi (70 to 200 bar). The high-pressure system typically produces very fine droplets (less than 50 um) and uses even smaller pipe sizes than that of low to intermediate pressure systems. 2 White Paper - AquaMist Fire Protection System

A twin-fluid system is a hybrid water mist system like the AquaMist SONIC System. This system requires water and nitrogen gas to extinguish the fire. Both the water and the nitrogen gas require separate sources towards the nozzle and then the gas is used to shear the water stream into fine water droplets. AquaMist SONIC uses operating pressures of 58.02 psi to 101.52 psi for nitrogen and 29.00 psi to 58.02 psi (4 to 7 bar for nitrogen and 2 to 4 bar for water) at the nozzles before entering the protected area to extinguish the fire. The hybrid water mist system works as described previously; by cooling the surroundings and displacing oxygen, but now the inert nitrogen gas helps to further reduce the overall oxygen level in the space for faster extinguishment of fire. This system uses less inert gas than what is required in a traditional clean agent system because it utilizes the benefits of the local oxygen displacement created by the conversion of water mist to steam. For each water mist system, different configurations can be found. There are automatic systems which utilize nozzles that have a thermal responsive element that hold back water until it operates. When exposed to a certain high temperature (from a fire) for a period of time, this thermal response element operates and allows water to come out of the nozzle. These nozzles can be piped from a wet sprinkler valve or a pre-action valve. Regardless of the system type, wet or pre-action, water only enters the protected area from those nozzles of which the thermal response element has operated. Another type of system is the deluge system. This system utilizes open nozzles (no thermal element). With this system, an independent detection system (smoke or heat) is installed in the same area as the nozzles to control the deluge alarm valve. When smoke or heat is detected, an electronic signal is sent to a control panel which in turn sends a signal to the deluge valve and opens the valve. Water enters the system and provides water to all the nozzles connected to the deluge valve. This provides protection for hazards within the space and is commonly seen in machinery and turbine enclosures. The common name used for these types of water mist systems is a total flooding or total compartment system. When the compartment containing the machinery or turbine enclosure is of such a volume that a total compartment solution is not feasible, it will be decided to just protect the hazard locally with open nozzles and separate detection. This water mist system type is called a local application. BENEFITS OF WATER MIST The main benefit of water mist is that it uses less water compared to a traditional sprinkler system. This minimizes damage to the property and the critical assets. Also, due to the lower water requirements, the system can use smaller diameter piping. This may reduce the material cost as well as the installation cost of the system. A trade-off of using less water is that the water mist system typically needs higher pressure than what a municipal water Digital integrity is a crucial aspect of commercial organizational operations around the world. White Paper - AquaMist Fire Protection System 3

HELPING PROTECT YOUR BUSINESS AND VALUED ASSETS WITH WATER MIST FIRE PROTECTION SYSTEM main can provide. This can be accomplished by using positive displacement pump(s) which provide high-pressure output at lower water volumes, or by using stored nitrogen or air cylinders as a propellant for the water. Since the water demand is lower, water mist systems are suitable for standalone applications where access to water may be limited. In such situations, a water tank or cylinder(s) filled with water and pressurized by stored nitrogen or air cylinders can be used to supply the pump with water. With these standalone solutions, there is a finite discharge duration due to limited amount of water stored. WHAT APPLICATIONS ARE BEST SUITED FOR WATER MIST TECHNOLOGY? Water mist systems can be used as a complete solution for nearly every class of fire. Examples of where water mist systems have been used include, but are not limited to, archives, cable tunnels, data centers, heritage, hotels, industrial fryers, libraries, machinery spaces, offices and turbine enclosures. Machinery spaces are facilities providing process critical services, such as water, electricity, heating and power. Machinery spaces that utilize hydrocarbon fuels and lubricants, as well as flammable and combustible liquids under pressure, can create fast-growing spray and pool fires. This type of fire suppresses quickly when using an applicable water mist solution due to its rapid heat absorption. Large, industrial fryers can also benefit from water mist technology. Food manufacturers using large industrial fryers can suffer significant loss with fires that cause widespread damage and product loss (up to $1 million per day). Water mist nozzles can be installed directly within the hood system of the fryer to prevent fire from spreading. Heritage sites, such as museums, libraries and art galleries contain high-value, irreplaceable assets. While fire poses a tremendous risk to the preservation of these assets, saturation from fire suppression systems can also cause significant damage. The lower water discharge of water mist systems helps reduce collateral damage to these assets without sacrificing fire protection capabilities. SPECIFYING A WATER MIST SOLUTION The following considerations should be taken into account when specifying a water mist system. The first is the on-site water supply. The available water pressure often dictates the required water supply for the water mist system. If there is no adequate water supply, then a standalone system may be required as described previously. Secondly, water mist systems should conform to all local and state codes, where applicable, as well as the requirements of the authority having jurisdiction (AHJ). For example, water mist systems should meet the requirements outlined by NFPA 750, Standard on Water Mist Fire Protection Systems. Systems and/ or components of water mist systems are tested and approved by certifying bodies such as Factory Mutual (FM), Underwriters Laboratory (UL) and VdS, and these listings and approvals are often required by standards and AHJs. Industrial fryers are cookers commonly used in the food industry to produce consumables. 4 White Paper - AquaMist Fire Protection System

MAKE THE RIGHT CHOICE Although water mist systems have been around for many years, they ve only recently gained popularity in the U.S. These systems offer a powerful and economical solution that will help suppress or control the fire with minimal water usage and collateral damage. The innovative, dependable and environmentally safe technology behind AquaMist systems is supported by comprehensive industry approvals as well as independent, third-party testing and verification. The diversity of the AquaMist line, backed by the forward-thinking technology of Johnson Controls, assists in allowing companies to select a water mist solution that fits the unique needs of their business. For more information on AquaMist Water Suppression Systems, submit a contact form at http://tycoaquamist.com AquaMist ULF produces droplets of water through a range of nozzles, which are specifically engineered and approved for a variety of fire hazards. Designed to function as one dedicated fire protection system, it s a complete engineered solution that includes pumps, valves, discharge nozzles, pipes and fittings. Environmentally friendly AquaMist SONIC uses readily available water and nitrogen as extinguishing material. Two supersonic atomizers create 1.5 trillion superfine water droplets per second and propel them at high velocity to provide non-toxic fire suppression protection. This system also provides automatic detection and actuation and/ or remote manual actuation. As a pre-engineered cylinder or engineered pumped system, AquaMist FOG provides fire protection for class A and B fires. Because these systems reduce water consumption and pipe diameters, they are perfect for machinery spaces, as well as fragile infrastructures that requires specialist care, such as in heritage buildings, libraries and archives. This system is not yet available in North America. Contributions By: Ian Jutras, Project Engineer - Water Mist, Johnson Controls, Dennis Visser, Global Product Manager - Water Mist, Johnson Controls, Dennis M. Phillips, Business Development Manager - Johnson Controls, Seth Wood, Business Development Manager - Johnson Controls White Paper - AquaMist Fire Protection System 5

About Johnson Controls Johnson Controls is a global diversified technology and multi-industrial leader serving a wide range of customers in more than 150 countries. Our 120,000 employees create intelligent buildings, efficient energy solutions, integrated infrastructure and next generation transportation systems that work seamlessly together to deliver on the promise of smart cities and communities. Our commitment to sustainability dates back to our roots in 1885, with the invention of the first electric room thermostat. We are committed to helping our customers win and to creating greater value for all of our stakeholders through strategic focus on our buildings and energy growth platforms. For more information, visit www.johnsoncontrols.com or follow @johnsoncontrols on Twitter. About Johnson Controls Building Technologies and Solutions Johnson Controls Building Technologies & Solutions is making the world safer, smarter and more sustainable one building at a time. Our technology portfolio integrates every aspect of a building whether security systems, energy management, fire suppression or HVACR to ensure that we exceed customer expectations at all times. We operate in more than 150 countries through our unmatched network of branches and distribution channels, helping building owners, operators, engineers and contractors enhance the full lifecycle of any facility. Our arsenal of brands includes some of the most trusted names in the industry such as Tyco, YORK, Metasys, Ruskin, Titus, Frick, PENN, Sabroe, Simplex and Grinnell. For more information, visit www.johnsoncontrols.com or follow @JCI_Buildings on Twitter. WORLDWIDE HEADQUARTERS Johnson Controls, 1400 Pennbrook Parkway Lansdale, PA 19446 Tel: +1 215-362-0700 (Toll Free) Tel: +1 800-558-5236 Fax: +1 800-877-1295 www.tyco-fire.com EUROPE Johnson Controls Kopersteden 1 P.O. Box 198 7500 AD Enschede The Netherlands Tel: +31 (0)53-428-4444 www.tfppemea.com ASIA PACIFIC Johnson Controls, 2 Serangoon North Avenue 5 Tel: +65-6577-4360 Fax: +65-6481-8791 www.tyco-fire.com 2018 Johnson Controls. All rights reserved.