FIRE PROTECTION, NATURALLY AQUASONIC Water-Atomizing Fire Suppression System

Similar documents
I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

SUPERIOR THINKING. DEEPER DIGGING. Underground Mining Fire Suppression Systems

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems

CUTTING-EDGE PROTECTION Forestry Equipment Fire Suppression Solutions

Water Mist Fire Suppression

TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

Typical Applications: Excavators Haul Trucks Wheeled Loaders Drag Lines Large Dozers Drills

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers

What provides highly reliable fire protection?

SECURITY BLANKET Foam Fire Protection Products

TRUSTED PERFORMANCE. Carbon Dioxide Fire Suppression Systems

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

ANSUL TO-ANSUL. For more information... Check your local Yellow Pages for your authorized Ansul Restaurant Systems Distributor.

What is HI-FOG? The natural enemy of fire

A Guide for Meeting NFPA 10 Subsection

Hospitals and Major Medical Centers

THE WORLD LEADER. in special hazard fire suppression solutions

Safer. Smarter. Tyco. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker.

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

PREVENT SYSTEMS WHEN SAFETY IS TAKEN SERIOUSLY

Watermist Fire Protection of Plant Rooms

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

How can I protect invaluable assets and the environment from the effects of a fire?

XC10 combined fire detection and extinguishing control

Superior by Design The Kidde ADS TM FM-200 System

MORE THAN JUST FIRE PROTECTION

Water Mist in Care Homes & Hospitals in the Nordic Territory. Henrik Johansson

Protection on the move Vehicle Automatic Fire Suppression System (AFSS)

XC10 combined fire detection and extinguishing control

JET-X HIGH-EXPANSION FOAM GENERATORS Data/Specifications

How can you minimize consequential damages in case of a fire?

Twin-Agent Fire Fighting/Securing Systems Specifications

Fire fighting excellence. HI-FOG water mist fire protection

TECHNICAL NOTES. Literature Review on Hybrid Fire Suppression Systems. Peter Raia Michael J. Gollner University of Maryland

Fire fighting excellence. HI-FOG water mist fire protection

Fire Suppression Investor Overview

FEMA Recommendations for Protection of Curtained Limited Finishing Workstations using UL 1254 Listed Pre engineered Dry Chemical Systems

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

Engineering Simulation in Built Environment and Civil Engineering Projects

Fire suppression systems for server rooms and data centres

MORE THAN JUST FIRE PROTECTION

FEMA RECOMMENDATIONS FOR PROTECTION OF CURTAINED LIMITED FINISHING WORKSTATIONS USING UL 1254 LISTED PRE-ENGINEERED DRY CHEMICAL SYSTEMS

Nessie High Pressure Water Mist Components for Fire Fighting

WATER MIST CONVENTION AND EXHIBITION

High flying fire protection HI-FOG for aircraft hangars

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

Connected: Global protection, all together

Explosion Protection of an Armoured Vehicle Crew Compartment with Water Mist. Andrew Kim and George Crampton

WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO

Performance Based Fire Protection With Water Mist

Report on First Revision June 2014 NFPA 5000

Fire fighting excellence. HI-FOG water mist fire protection

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

SAPPHIRE. Gaseous Fire Suppression Systems. Delivering 3M Novec 1230 Fire Protection Fluid

MINIMAX FIRE PRODUCTS WHITE PAPER THE COST-BENEFIT ADVANTAGES OF REPLACING HALON WITH 725 PSI MX 1230 CLEAN AGENT FIRE SUPPRESSION SYSTEMS

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

SECTION FM-200 FIRE SUPPRESSION SYSTEM

Types of Detection. Fusible Link Detection - Most Common

WATER MIST SYSTEMS. Table of Contents

Fire protection solutions for ships and offshore facilities

Fire and Extinguishing Tests on Computer Equipment

Report on First Revision November 2013 NFPA 750

The Science Behind Water Mist Protection of Typical Building Hazards

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

Water Mist System. Principle of Water mist evolves from combination of 3 main effects:

Australian Standard. Water mist fire protection systems System design, installation and commissioning AS

Machinery Space Fire Protection System from an Approved Product Portfolio

AQUAMIST Mist Control Center (MCC) Pump Skid Unit. General Description. Technical Data. Page 1 of 8 JANUARY 2016 TFP2270. Worldwide Contacts

What extinguishes fires without pressure peaks?

SEMICONDUCTOR FABRICATION FACILITIES

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

FIRE SUPPRESSION SYSTEM

ODS & SGG Alternatives for the Fire Protection Industry 2018

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

Update on European Standardization Work

FIre Extinguishers. K-GUARD Wet Chemical Fire Extinguishers Manual INSTALLATION 2014-DEC-29 REV. 03 PAGE 1 EXTINGUISHERS

Intelligent Security and Fire Solutions. Southern Africa

Premium Efficient OIL-FREE Compressors

SEMICONDUCTOR FABRICATION FACILITIES

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

KD Innovative extinguishing with Novec TM 1230 by 3M TM

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

Rick Seidel Fike Corporation Regional Sales Manager

ISO INTERNATIONAL STANDARD. Fire protection Automatic sprinkler system Part 9: Requirements and test methods for water mist nozzles

R-102 RESTAURANT FIRE SUPPRESSION SYSTEM

MODULE 2. Water-Based Suppression System Basics

CHANGING THE WORLD OF INDUSTRIAL FIRE PROTECTION

FOREFRONT AT THE OF PROTECTION

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

SHIPBUILDING FIRE PROTECTION WATER MIST SYSTEM SAID. DONE!

GENERAL BULLETIN NO. 5397

Transcription:

FIRE PROTECTION, NATURALLY AQUASONIC Water-Atomizing Fire Suppression System

A LOOK INSIDE THE INNOVATION The ANSUL AQUASONIC TM Water-Atomizing Fire Suppression System is a revolution in Class B fire protection. Compared to typical water mist systems, the AQUASONIC system produces a higher volume of smaller water droplets and projects them further. The highperformance fire suppression system is specifically engineered to cover a wide range of industrial, commercial, and institutional special hazard applications. The AQUASONIC Fire Suppression System utilizes non-toxic and readily available extinguishing media (water and nitrogen). AQUASONIC twin-fluid technology is safe for people, environment friendly, and inexpensive to recharge. The dependable system has few moving parts and uses tested technology with decades of proven service. Plus, there s no need for enclosure integrity tests, because the AQUASONIC system has been tested and approved with the door open. FM APPROVED ENVIRONMENTALLY SAFE FULLY SELF-CONTAINED MINIMAL WATER DISCHARGE EFFECTIVE ON CLASS B FIRES FLEXIBLE SYSTEM PIPING AND ATOMIZER LOCATION OPTIMIZED, PROTECTED VOLUME WITH MINIMAL PIPING AND SYSTEM DISCHARGE DEVICES

YOU VE NEVER SEEN WATER DO THIS Class B flammable liquid hazards can be protected by the total flooding abilities of the AQUASONIC system. Two supersonic atomizers create 1.5 trillion superfine water droplets per second, producing a combined surface area of 1302 ft 2 (121 m 2 ) per second. This is equivalent to the surface of an Olympic-size soccer field in one minute. Plus, the atomizers propel the droplets at high velocity throughout the combustion zone. PRINCIPLES OF OPERATION The atomizer is the key to the effectiveness of the AQUASONIC system.* Patented supersonic technology generates a high-velocity, low-pressure zone that draws a thin sheet of water into a primary atomization region. A conical supersonic wave then creates a zone of extreme acceleration and high shear-rate, breaking the sheet into atomized droplets. Fire suppression is achieved once the droplets reach the target, extracting heat from the fire. *This system should not be used for direct application to materials that react violently with water or produce hazardous products. AQUASONIC PRINCIPLES OF OPERATION Water expelled as thin sheet Nitrogen Contraction: High-velocity, low-pressure zone draws water into primary atomization region Characteristic conical supersonic wave creates zone of extreme acceleration and high shear-rate, breaking the thin sheet of water into atomized droplets Water **

THIS SYSTEM HAS WHAT IT TAKES The AQUASONIC atomizer features 100% machined stainless steel construction for superior strength, no internal moving parts for extreme dependability, and multiple mounting options and configurations for ease of installation. The self-contained AQUASONIC system is constructed of industry-recognized, proven ANSUL components. Capable of automatic detection and actuation and/or remote manual actuation, the system is installed and serviced by authorized ANSUL distributors. THE AQUASONIC FIRE SUPPRESSION SYSTEM IS: Fast high-volume, high-velocity discharge quickly fills spaces Smart uses one-third the water of comparable high-pressure water mist systems Lower Pressure less than 10% of the pressure required of high-pressure water mist systems A SMART ALTERNATIVE Other fire suppression systems can t do what the AQUASONIC system does. Traditional CO 2 systems haven t proven to be people-friendly and single-fluid water mist systems may have reached the limits of their capabilities. The AQUASONIC system knocks down fires better and is safe for people and the environment. FM APPROVED The AQUASONIC system extinguished all fire scenarios in the FM protocol in less than 5 minutes, including scenarios in which extinguishment was not required in order to pass. Water flow rate through two atomizers was a total of 3 gallons per minute (11.4 liters per minute) with atomizers mounted in the ceiling or on sidewalls.

THE AQUASONIC FIRE SUPPRESSION SYSTEM GIVES YOU OPTIONS In terms of placement, AQUASONIC atomizers offer maximum flexibility. A total of two atomizers can be mounted to... the ceiling 4.0 to 11.0 feet (1.2 to 3.4 meters) from adjacent walls and up to 22 feet (6.7 meters) apart the walls at least 3.4 feet (1.0 meter) from the nearest corner and 12.5 to 39.3 feet (3.8 to 12.0 meters) from the opposite wall APPLICATIONS: MACHINERY AREAS The supply unit can be placed anywhere with these considerations: water pipe volume less than 13 gallons (50 liters), nitrogen pipe volume less than 7.1 cubic feet (0.201 cubic meters), and relative elevation change between supply unit and atomizers of +105 feet (+32 meters) or -70 feet (-21 meters). IF ANYONE WAS GOING TO DEVELOP A NEW WAY TO USE WATER, IT WAS ANSUL Ansul continues to lead the fire suppression industry with a full range of quality solutions and specialized products backed by a worldwide network of factory-trained distributors the largest and most qualified in the industry. The AQUASONIC Fire Suppression System is another exclusive innovation in the ANSUL fire protection line. Choose to protect people and assets with the name you know. Ansul. INSULATED AND NON-INSULATED COMBUSTION TURBINE ENCLOSURES PUMP ROOMS FLAMMABLE LIQUID STORAGE GENERATORS TRANSFORMER VAULTS GEAR BOXES OIL PUMPS AND TANKS

Ansul Incorporated One Stanton Street Marinette, WI 54143-2542 800-862-6785 (United States, Canada) 715-735-7411 (International) www.ansul.com Copyright 2008 Ansul Incorporated ANSUL and AQUASONIC are trademarks of Ansul Incorporated or its affiliates. **Image used with permission. Form No. F-2008080