50A Integrated Furnace Control

Similar documents
50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

50A Integrated Furnace Control

Operator: Save these instructions for future use!

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

50M TYPICAL WIRING DIAGRAM 24 VAC CLASS II TRANSFORMER 24 VAC 50M COOL PARK HEAT LO HEAT HI LINE XFMR EAC HUM

WARNING CAUTION 50T INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS. Integrated Furnace Control

A-1106 ACCESSORY KIT INSTALLATION INSTRUCTIONS IGNITION CONTROL P/N S , S , S

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

40 Residential Gas Furnace Operation

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

BGH Series Hot Surface Ignition Control

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Hot Surface Ignition (HSI) System Booklet

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

Emerson Blue Easy Set 1H/1C

24 VAC Direct Spark Gas Ignition

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

59MN7A Series 100 TROUBLESHOOTING GUIDE

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

Quick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features

Installation and Operating Instructions

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Interrupted Ignition Series Oil Primary Control

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

*9MAC TROUBLESHOOTING GUIDE

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

24 VAC Intermittent Pilot Gas Ignition Control

Troubleshooting Guide

Model 60200FR Gas Primary Control Data Sheet

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Operator: Save these instructions for future use!

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

Model Universal Oil Primary Control

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

Operator: Save these instructions for future use!

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

SV9520H SmartValve System Control Line Voltage Polarity Sense Models

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Technical Information

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Technical Manual MAY 2008 Edition

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

Troubleshooting Guide

PRODUCT SPECIFICATIONS 1 *UH2B080A942VA

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

TECHNICAL MANUAL. GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

Operator: Save these instructions for future use!

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

1F98EZ-1421, Easy Install

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

I/O ZONE 560/583 AND OPERATION MANUAL

Upflow/ Horizontal Left/Right, Downflow Single and 2 Stage Non-Condensing Gas Fired Furnace

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215)

Heat Pump Defrost Board Replacement Kit

Operator: SaVe these instructions forfuture use

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

USER S INFORMATION, MAINTENANCE AND SERVICE MANUAL

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

*DD2B060A9V3VA *DD2B080A9V3VA *DD2C100A9V5VA *DD2D120A9V5VA

CSD-1 COMMERCIAL BOILER CONTROLS

Service and Maintenance Instructions For Sizes , Series B & C

SV9540; SV9640 SmartValve System Controls

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

Service Guide. 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. PG9MAB Series A

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

4-Way Multipoise Fixed-Capacity Dual-Vent Condensing Gas Furnace

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

COMMERCIAL GAS WATER HEATERS

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

GAS UNITS KITS AND ACCESSORIES 505,172M 08/06

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

service and maintenance procedures

EG & PEG Series 5 EGH Series 5

Statement of Responsibilities

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

Technical

Transcription:

50A56-956 Integrated Furnace Control INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION The 50A56-956 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. Signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shut-off during normal operation. These controls incorporate system fault analysis for quick gas flow shut-off, coupled with automatic ignition retry upon sensing a fault correction. Kit includes: 1) Ignition Control 3) Install Sheet 2) Metal Control Box 50A56-956 Cross Reference Information York White-Rodgers S1-33102956000 S1-03101266000 50A56-242 S1-03109167000 S1-03101284000 50A56-243 S1-03101933000 S1-03101973000 S1-03101267000 S1-03101972000 S1-03101267001 265901 S1-03100662000 265902 S1-03101250000 539617 S1-33103010000 PRECAUTIONS Installation should be done by a qualified heating and air conditioning contractor or licensed electrician. If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or licensed electrician. Do not exceed the specification ratings. All wiring must conform to local and national electrical codes and ordinances. This control is a precision instrument, and should be handled carefully. Rough handling or distorting components could cause the control to malfunction. Following installation or replacement, follow manufacturer s recommended installation/service instructions to ensure proper operation. CAUTION! Do not short out terminals on gas valve or primary control. Short or incorrect wiring may damage the thermostat. CONTENTS Description... 1 Precautions... 1 Specifications... 2 Installation... 3 Mounting & Wiring Operation... 6 Troubleshooting... 8! WARNING Failure to comply with the following warnings could result in personal injury or property damage. FIRE HAZARD Do not exceed the specified voltage. Replace existing control with exact model and dash number. Protect the control from direct contact with water (dripping, spraying, rain, etc.). If the control has been in direct contact with water, replace the control. Label all wires before disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Route and secure wiring away from flame. SHOCK HAZARD Disconnect electric power before servicing. Ensure proper earth grounding of appliance. Ensure proper connection of line neutral and line hot wires. EXPLOSION HAZARD Shut off main gas to appliance until installation is complete. www.white-rodgers.com www.emersonclimate.com PART NO. 37-7475B Replaces 37-7475A 1419

SPECIFICATIONS ELECTRICAL RATINGS [@ 77 F (25 C)]: Input Voltage: 25 VAC 50/60 Hz Max. Input Current @ 25 VAC: 0.45 amp Relay Load Ratings: Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf Ignitor Relay: 6.0 amp @ 120 VAC 50/60 Hz (resistive) Inducer Relay: 2.2 FLA 3.5 LRA @ 120 VAC Circulator Relay: 14.5 FLA 25.0 LRA @ 120 VAC Flame Current Requirements: Minimum current to insure flame detection: 1 µa DC* Maximum current for non-detection: 0.1 µa DC* Maximum allowable leakage resistance: 100 M ohms *Measured with a DC microammeter in the flame probe lead OPERATING TEMPERATURE RANGE: -40 to 176 F (-40 to 80 C) HUMIDITY RANGE: 5% to 93% relative humidity (non-condensing) MOUNTING: Surface mount multipoise Timing Specs: (@ 60 Hz**) Flame Establishing Time: Flame Failure Response Time: maximum 0.8 sec 2.0 sec Gases Approved: Natural, Manufactured, Mixed, Liquified Petroleum, and LP Gas Air Mixtures are all approved for use. **At 50% Hz, all timing specifications should be increased by 20% 2 Pre-Purge Trial for Ignition Period (TFI) Ignition Activation Period (IAP) Retries Recycles Valve Sequence Period Interpurge Post-Purge TIMING SPECIFICATIONS (All times are in seconds, unless noted otherwise) Event Definition 50A56-956 The period of time intended to allow for the dissipation of any unburned gas or residual products of combustion at the beginning of a furnace operating cycle prior to initiating ignition The period of time between initiation of gas flow and the action to shut off the gas flow in the event of failure to establish proof of the supervised ignition source or the supervised main burner flame. The period of time between energizing the main gas valve and deactivation of the ignition means prior to the end of TFI The additional attempts within the same thermostat cycle for ignition when the supervised main burner flame is not proven within the first trial for ignition period. The additional attempts within the same thermostat cycle for ignition after loss of the supervised ignition source or the supervised main burner flame. Valve sequence period equals 7 seconds trial for ignition period x (1 initial try + 2 retries) + 12 seconds. The period of time intended to allow for the dissipation of any unburned gas or residual products of combustion between the failed trial for ignition and the retry period. The period of time intended to allow for the dissipation of any unburned gas or residual products of combustion at the end of a furnace burner operating cycle. Post-purge begins at the loss of flame sense. 0 7 5 2 times Lockout Time ANSI standard rated module timing. 140 Heat Delay-To-Fan-On The period of time between proof of the supervised main burner flame 30 and the activation of the blower motor at Heat speed. Heat Delay-To-Fan-Off* The period of time between the loss of a call for heat and the 60/90/120*/180 deactivation of the blower motor at Heat speed. Cool Delay-To-Fan-On The period of time after a thermostat demand for cool before energizing 0 the circulator blower motor at Cool speed. Cool Delay-To-Fan-Off* The period of time between the loss of a call for cool and the 60 deactivation of the blower motor at Cool speed. Initial Ignitor Warm-up The length of time allowed for the igniter to heat up prior to the initiation 17 of gas flow. Ignitor Warm-up Retries In the event of a retry, the warm-up time will be increased by one 27 second, up to a maximum of 27 seconds, and locked at that duration Auto Reset After one (1) hour of internal or external lockout, the control will 60 minutes automatically reset itself and go into an auto restart purge for 60 seconds. Electronic Air Cleaner Yes Humidifier *This time will vary depending on option switch position. The control is factory set at 120 seconds HEAT delay-to-fan-off. See OPERATION section for further information 4 21 15 15 Yes

! WARNING! CAUTION Failure to comply with the following warnings could result in personal injury or property damage. INSTALLATION Do not short out terminals on gas valve or primary control. Short or incorrect wiring may damage the thermostat. FIRE HAZARD Do not exceed the specified voltage. Replace existing control with exact model and dash number. Protect the control from direct contact with water (dripping, spraying, rain, etc.). If the control has been in direct contact with water, replace the control. Label all wires before disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Route and secure wiring away from flame. SHOCK HAZARD Disconnect electric power before servicing. Ensure proper earth grounding of appliance. Ensure proper connection of line neutral and line hot wires. EXPLOSION HAZARD Shut off main gas to appliance until installation is complete. MOUNTING AND WIRING Certain upflow 90% models may require the installation of the provided metal control mounting box. The reuse of the existing door switch and transformer are required. Other models may require new mounting holes. In this case, use the mounting template located in figure 1. Specifically the BGU model furnaces may required not only new mounting holes, but also relocation of the existing transformer. In all cases the wiring connections will remain the same. All wiring should be installed according to local and national electrical codes and ordinances. The control must be secured to an area that will experience a minimum of vibration and remain below the maximum ambient temperature rating of 175 F. The control is approved for minimum ambient temperatures of -40 F. Any orientation is acceptable. Refer to the wiring diagram, page 4 and wiring table, page 5 when connecting the 50A56 control to other components of the system. UL approved, 105 C rated 18 gauge, stranded, 2/64 thick insulation wire is recommended for all low voltage safety circuit connections. UL approved 105 C rated 16 gauge min., stranded, 4/64 thick insulation wire is recommended for all line voltage connections. After installation or replacement, follow appliance manufacturer s recommended installation or service instructions to ensure proper operation. 3

HOT (LINE) TYPICAL SYSTEM WIRING DIAGRAM 120 VAC NEUTRAL (LINE) 24 VAC CLASS II TRANSFORMER TH 24 VAC 50A56 TR HUMIDIFIER LO COOL HI COOL HEAT PARK PARK LINE XFMR EAC HUM IND-N IND IGN IGN-N INDUCER IGNITOR CIRCULATOR BLOWER ELECTRONIC AIR CLEANER CIR N LINE N XFMR N HUM N EAC N Y/Y2 Y/Y2 W G W G COMPRESSOR CONTACTOR 50A56 in other furnace(s) TWINNING APPLICATIONS ONLY TWIN * R C Y1 TWIN R Y1 THERMOSTAT FLAME SENSOR PROBE PS HLI HLO FP ROS GND ROSI MV MV COM TR TH HIGH LIMIT (N. C.) ROLLOUT (N. C.) PRESSURE SWITCH (N. O.) AUX. HIGH LIMIT (N. C.) GAS VALVE LEGEND Low Voltage (24 VAC) Line Voltage (120 VAC) N. C. = Normally closed switch N. O. = Normally open switch *For two stage cooling mode only 4

TYPICAL SYSTEM WIRING TABLE 50A56 TERMINAL W G R Y/Y2 Y1 C HLO (Pin 1) FP (Pin 2) TH (Pin 3) Not Used (Pin 4) ROS (Pin 5) TR (Pin 6) HLI (Pin 7) GND (Pin 8) MV COM (Pin 9) PS (Pin 10) ROSI (Pin 11) MV (Pin 12) IND (Pin 1) IGN (Pin 2) IND-N (Pin 3) IGN-N (Pin 4) LO COOL HI COOL HEAT PARK (2 terminals) LINE XFMR EAC (optional) HUM (optional) CIR N LINE N XFMR N EAC N (optional) HUM N (optional) TWIN HLO FP TH IND TERMINAL TYPE Terminal block with captive screws ROS TR IGN HLI GND MV COM IND N PS ROSI MV IGN N SYSTEM COMPONENT CONNECTION low voltage thermostat W terminal (or equivalent) low voltage thermostat G terminal (or equivalent) low voltage thermostat R terminal (or equivalent) low voltage thermostat Y terminal (or equivalent) (2nd wire from Y terminal goes to 24 VAC HOT side of compressor contactor coil) low voltage thermostat Y1 terminal (or equivalent) 24 VAC COMMON side of compressor contactor coil high limit OUTPUT flame sensor probe 24 VAC transformer (low voltage HIGH side) rollout switch OUTPUT 24 VAC transformer (low voltage COMMON side) high limit INPUT MUST BE RELIABLY GROUNDED TO CHASSIS Main Valve Common pressure switch INPUT rollout switch INPUT gas valve inducer HOT side ignitor HOT side inducer NEUTRAL side ignitor NEUTRAL side circulator blower LO COOL SPEED terminal circulator blower HI COOL SPEED terminal circulator blower HEAT SPEED terminal unused circulator blower terminal input voltage (120 VAC) HOT side 24 VAC transformer line voltage HOT side electronic air cleaner HOT side humidifier HOT side circulator blower NEUTRAL terminal input voltage (120 VAC) NEUTRAL side 24 VAC transformer line voltage NEUTRAL side electronic air cleaner NEUTRAL side humidifier NEUTRAL side one wire twinning terminal Maximum recommended flame probe wire length is 36 inches. 5

OPERATION OPTION SWITCHES The shunt jumper (E34) on the 50A56 control are used to determine the length of the heat delay-to-fan-off periods. The following table shows the time periods that will result from the various positions. E34 60 90 120 180 Factory Setting 120 Seconds BLWR OFF DELAY Heat Delay-to-Fan-Off Shunt Jumper E34 60 90 120 180 60 90 120 180 60 90 120 180 60 Seconds 90 Seconds 180 Seconds HEAT MODE In a typical system, a call for heat is initiated by closing the Thermostat W contacts. This starts the control s heating sequence. The inducer blower and optional humidifier are energized. After the pressure switch is proven the ignitor is energized and the warm-up time begins. The ignitor is allowed to warm up for a 17 seconds initial warm-up. The 120VAC ignitors with a 17-second warm-up time must be used. These ignitors are specially designed to heat up quickly at a low voltage condition without overheating at a high voltage condition. At the end of the ignitor warm-up time, both valves in the manifold gas valve are opened. Flame must be detected within 7 seconds. When flame is detected, the delay-to-fan-on period begins. After the 30 seconds delay-to-fan-on period ends, the optional electronic air cleaner is energized and the circulator fan is energized at heat speed. When the thermostat is satisfied, the gas valve is de-energized. After proof of flame loss, the selectable heat delay-to-fan-off period begins and the inducer blower remains energized to purge the system for 15 seconds. When the purge is complete, the inducer blower and humidifier are de-energized. After the delay-to-fan-off period ends, the circulator fan and electronic air cleaner are de-energized. If flame is not detected, both valves are de-energized, the ignitor is turned off, and the control goes into the retry sequence. The retry sequence provides a 15- second purge period following an unsuccessful ignition attempt (flame not detected). After this wait, the ignition sequence is restarted with a 27 second ignitor warm-up time. The control will allow 2 retry periods before entering system lockout. If flame is established for more than 10 seconds after ignition, the controller will clear the ignition attempt (or retry) counter. If flame is lost after 10 seconds, it will restart the ignition sequence. During burner operation, a momentary loss of power of 50 milliseconds or longer will de-energize the main gas valve. When power is restored, the gas valve will remain deenergized and a restart of the ignition sequence will begin immediately. A momentary loss of gas supply, flame blowout, or a shorted or open condition in the flame probe circuit will be sensed within 2.0 seconds. The gas valve will de-energize and the control will restart the ignition sequence. Recycles will begin and the burner will operate normally if the gas supply returns, or the fault condition is corrected. If the control has gone into system lockout, it may be possible to reset the control by a momentary power interruption of one second or longer. Refer to SYSTEM LOCKOUT FEATURES. SINGLE STAGE COOL MODE In a typical single stage cooling system, a call for cool is initiated by closing the thermostat contacts, Y/Y2. This energizes the control and the compressor. The cool delay-tofan-on period begins. After the delay period ends, the optional electronic air cleaner is energized, and the circulator fan is energized at high cool speed. After the thermostat is satisfied, the compressor is de-energized and the cool mode delay-tofan-off period begins. After the delay-to-fan-off period ends, the circulator fan and electronic air cleaner (optional) are de-energized. TWO STAGE COOLING MODE In a typical two stage cooling system, a call for cool is initiated by closing the Y1 thermostat contacts. This energizes the control and first stage of the compressor. The cool delay-tofan-on period begins. After the delay period ends, the optional electronic air cleaner is energized, and the low cooling circulator fan is energized. When second stage cooling is called for the thermostat will energize Y/Y2. This will energize the second stage of the compressor and high cooling speed of the indoor circulating fan. After the thermostat is satisfied, the compressor is deenergized and the cool mode delay-to-fan-off period begins. After the delay-to-fan-off period ends, the circulator fan and electronic air cleaner (optional) are de-energized. 6

OPERATION MANUAL FAN ON MODE If the thermostat fan switch is moved to the ON position, the optional electronic air cleaner and circulator fan are energized. The circulator speed is selectable via shunt jumper option E33. Three choices that can be made are Lo Cool, Heat or Hi Cool. By moving the shunt jumper location, the desired continuous fan speed will be attained. When the fan switch is returned to the AUTO position, the circulator fan and electronic air cleaner (optional) are de-energized. E33 LO COOL HEAT HI COOL Factory Setting HI COOL Manual Fan Speed Shunt Jumper E33 CONT FAN SPEED LO COOL HEAT HI COOL LO COOL TWINNING INTERFACE LO COOL HEAT HI COOL HEAT The control is equipped with a single wire twinning interface which is a 3/16" spade terminal designated as "TWIN". If twinning is used, either control will process a call for heat, cool or fan as described above. However, after the heat-, cool-, or fan-on delay time expires, both units will energize the circulator blowers at the same time. Likewise, after the heat-, cool-, or fan-off delay time expires, both units will de-energize the circulator blowers at the same time. This allows for proper air flow to be obtained. To assure proper control operation, both controls must share a common transformer ground (TR). To enable twinning, do the following. 1. Power supplied to both furnaces must be from the same phase of the 24 VAC power to the control. 2. Connect the TWIN terminals on the controls of the furnaces to be twinned to each other using a single wire (14-22 AWG.). 3. Both controls must be of the same model and type for the twinning feature to work properly. SYSTEM LOCKOUT SYSTEM LOCKOUT FEATURES When system lockout occurs, the gas valve is de-energized, the circulator blower is energized at heat speed, and, if flame is sensed, the inducer blower is energized. The diagnostic indicator light will flash or glow continuously to indicate system status. (System lockout will never override the precautionary features.) To reset the control after system lockout, do one of the following: 1. Interrupt the call for heat or cool at the thermostat for at least one second but less than 20 seconds (if flame is sensed with the gas valve de-energized, interrupting the call for heat at the thermostat will not reset the control). 2. Interrupt the 24 VAC power at the control for at least one second. You may also need to reset the flame rollout sensor switch. 3. After one hour in lockout, the control will automatically reset itself. DIAGNOSTIC FEATURES The 50A56-956 control continuously monitors its own operation and the operation of the system. If a failure occurs, the LED will indicate a failure code as shown in the TROUBLESHOOTING. If the failure is internal to the control, the LED will stay on solid. In this case, the entire control should be replaced, as the control is not field-repairable. Failure codes will flash the LED in the following flashpause sequences to indicate failure status (each flash will last approximately 0.25 seconds, and each pause will last approximately 2 seconds). FAULT RECALL The last five fault codes stored can be displayed on the diagnostic LED. When the control is in standby mode (no call for heat or cool), press the FAULT RECALL switch for approximately two to five seconds and release. The fault codes will display beginning with the most recent fault first with a one second pause between codes. After the stored fault codes have all displayed, the LED will return to normal status. While displaying the stored fault codes, the control will ignore any new call for heat, cool or fan. If no fault codes are in memory, the LED will flash two green flashes then return to normal status. FAULT CODE RESET The stored fault codes can be erased from memory. When the control is in standby mode (no call for heat or cool), press the FAULT RECALL switch for five to ten seconds or until the diagnostic LED begins to rapid flash. When the switch is released, the LED will flash three green flashes when memory has been cleared. The 50A56-956 has only one serviceable part an automotive type fuse, which protects the low voltage transformer from damage if the output is short-circuited. If the fuse has opened up, remove whatever caused the short circuit and replace the fuse with only a 3 Amp automotive type fuse. If the fuse does not correct the condition, replace the entire control. There are no other user serviceable parts. 7

TROUBLESHOOTING Green LED Flash 8 Amber LED Flash Red LED Flash Error/Condition Slow Normal operation No fault 1 Flame sensed when no flame should be present 2 Pressure switch stuck closed/inducer error 3 Pressure switch stuck open/inducer error Comments/Troubleshooting Verify the gas valve is operating and shutting down properly. Flame in burner assembly should extinguish promptly at the end of the cycle. Check orifices and gas pressure. Pressure switch stuck closed. Check switch function, verify inducer is turning off. Refer to wiring diagram, terminals PSI / HLO. Check pressure switch function and tubing. Verify inducer is turning on and pulling sufficient vacuum to engage switch. Refer to wiring diagram terminals, PS / HLI. 4 Open limit switch Verify continuity through limit switch circuit. Refer to wiring diagram terminals, HLI / HLO. 5 Open rollout switch/open fuse detect 6 Pressure switch cycle lockout Verify continuity through rollout switch circuit. Refer to wiring diagram terminals, ROSI / ROS. Check pressure switch function and tubing. Verify inducer is pulling sufficient vacuum to continuously engage switch. Refer to wiring diagram, terminals PS / HLO. 7 External lockout (retries) Failure to sense flame is often caused by carbon deposits on the flame sensor, a disconnected or shorted flame sensor lead or a poorly grounded furnace. Carbon deposits can be cleaned with emery cloth. Verify sensor is not contacting the burner and is located in a good position to sense flame. 8 External lockout (recycles) See above 9 Grounding or reversed polarity 10 Gas flow with no call for heat 11 Limit switch open blower failure Ignitor must be positioned to light the gas immediately when the valve opens. If the ignitor has been replaced, verify hot spot position has not changed. Check sensor lead for shorting and verify furnace is grounded properly. Verify gas supply to valve, gas valve in "On" position and appliance lighting properly. Verify flame reaches flame sensor during ignition attempts and gas pressures are correct. Verify the control and furnace are properly grounded. Check and reverse polarity (primary or secondary) if incorrect. Verify the gas valve is operating and shutting down properly. Check gas valve wiring. Verify continuity through limit switch circuit. Refer to wiring diagram terminals, HLI / HLO. 12 Ignitor failure Open ignitor circuit indicated. Check wiring or possibly a broken ignitor. Solid Rapid Internal GV error, micro, and frequency check Twinning error, incorrect 24V phasing Control failure. Replace control. Check that the 24V is phased correctly. 4 Y present with no G call Check wiring from thermostat. The control is not receiving a "G" call with a "Y" signal. Slow Normal operation with call for heat No fault Rapid Low flame sense current Low flame sense current is often caused by carbon deposits on the flame sensor, a poorly grounded furnace or a mis-aligned flame sense probe. Carbon deposits can be cleaned with emery cloth. Check or improve furnace and module ground. Verify sensor is located in or very near flame as specified by the appliance manufacturer. Refer to wiring diagram FS terminal and GND.

NOTES 9

10 NOTES

4.825" 7.0" 7.0" Note: Confirm actual size of template before using. Figure 1: Hole Template 4.825" 11

TECHNICAL SUPPORT: 1-888-725-9797 White-Rodgers is a business of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co. www.white-rodgers.com www.emersonclimate.com