Air distribution systems. Opticlean OC-Q... DS 4136 E /1

Similar documents
Air distribution systems. Opticlean OC-Q...

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

Air distribution systems. Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

Ceiling displacement outlet non-adjustable Q-DN... adjustable Q-DV...

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Ceiling diffusers. Type DLQL

Static cooling ceiling system SKS-4/3 DS 4094 E /1. Technical Selection

Krantz. Multifunction exposed ceiling AVACS. Cooling and heating systems

Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

Ceiling swirl diffusers

Units for suspended ceilings

Ceiling swirl diffusers

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

Units for suspended cei lings

KLIMA Active Chilled Beams

Cooling Strip Model SPB

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

CONDOR. Supply air ceiling QUICK FACTS

C o o l i n g a n d h e a t i n g s y s t e m s

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

Krantz. HVAC systems for hospitals. System solutions

CHILLED BEAM CASSETTE IQ STAR LYRA

Ceiling air diffuser INDULTHERM INDULTHERM-e

Air distribution systems. Air distribution systems for assembly rooms

Ceiling air diffuser INDULTHERM INDULTHERM-e

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

PARASOL EX. Suspended comfort modules QUICK FACTS

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

iq Star LYRA II chilled beam cassette

Air distribution systems. Displacement air outlets Low-turbulence air flow in the commercial sector

Halton Rex 600 Basic R6B - Active chilled beam

SKV, TPV Ventilation and extraction ceilings for industrial kitchens

Polaris-I-60. active chilled beam. the future of space conditioning

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow

Chilled Ceiling Elements

LØV-R. Svalbard-H. Chilled beam for corner installation between wall and ceiling

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

Primo Hotel. General. Indoor climate units for hotel rooms

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS

Halton Rex for Vario R6O - Variable air volume chilled beam

KCJ - Closed kitchen ceiling with Capture Jet system KCJ. Closed kitchen ceiling with Capture Jet system

Passive chilled beams

HOTEL CHILLED BEAM IQ STAR SILENCIA

Gas heaters and convectors ROBUR

Airflex Radial & ISO Thermal pipe

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Displacement air outlets Low-turbulence air flow in the industrial sector. Air distribution systems

CASSETTE UNIT. Comfort Circle

Type VDW WITH LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH INDIVIDUALLY MANUALLY ADJUSTABLE AIR CONTROL BLADES

Units for suspended ceilings Type DID632

Cassette units Model Comfort Circle. - heating - cooling - ventilation

ADAPT Parasol EX. Energy-saving, suspended comfort module QUICK FACTS

HRU SINGLE DWELLING HOUSES - BALANCED AIRFLOW WITH HEAT EXCHANGER AKOR ST HR Series

EASY VOLUME ADJUSTMENT INCLUDED FLEX CLAMP EXCELLENT THROW & FLOW HEATING AND COOLING TERMINAL REHEAT AVAILABLE

lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles

Heating and cooling ceiling systems Zehnder ZBN Planning document. Heating Cooling Fresh Air Clean Air

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Additional operating instructions according to ATEX 2014/34/EU Ceiling Impulse Diffuser Model PIL

Heating and cooling ceiling systems Suspended ceiling systems. Heating Cooling Fresh Air Clean Air

Air Excellent. Straightforward, effective air distribution

JSI-UV canopy - Ultraviolet and cyclonic filters, and supply air JSI-UV hoods Product Description Lights and filters

Air distribution systems. Sidewall air outlets Turbulent mixing air flow

VCD,VRD,VSD 4/5 GREEN TEMPERATURE OFFSET FOR WINTER HEATING AND COOLING CHANGEOVER MECHANICAL THERMAL MECHANISM

Heat Recovery Unit HERU. web-version

Contact, Overview, Index. Ceiling Heating/Chilled. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett. Capella.

EASY VOLUME ADJUSTMENT INCLUDED FLEX CLAMP EXCELLENT THROW & FLOW HEATING AND COOLING TERMINAL REHEAT AVAILABLE

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Halton CPT Passive Chilled Beam

Introduction This presentation describes tests undertaken by Frenger Systems Limited on a water driven radiant heating panel arrangement.

iq Star LYRA II chilled beam cassette

Fan Coil Unit CULTRA

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Heating and Cooling Ceiling Systems Comfortable and energy efficient. Heating Cooling Fresh Air Clean Air

Product catalogue. Air Distribution Systems Cooling and Heating Systems Filter Systems and Dampers. Krantz A trademark of Caverion

Smoke extraction duct of sheet steel

Fire dampers. For diverse applications

VARICOOL Velum. System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8

KOMFORT EC DB Suspended heat recovery air handling units

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Air Shower TECHNICAL DATA

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Orion-PTV LØV-R with Sirius

Orion-LØV LØV-R with Sirius

Chilled ceiling panel INDUCOOL-Compact

TECHNICAL SPECIFICATION

Fire protection unit

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

Recirculated air ceiling for operating rooms made by Krantz Components

EC Plug Fans EC FanGrid Retrofits for High Efficiency Air Handling Units

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

UniTrane U-Line ductable water terminals Optimum efficiency with a sound reduction bonus

American Society of Heating, Refrigerating and Air-Conditioning Engineers

installation, operation & Maintenance manual acb ceiling-mounted cassette models

Caice Attenuator Selector - Specifier Edition

TURBO HOODS. Product Brochure

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Transcription:

Air distribution systems Opticlean OC-Q... DS 136 E 06.13/1

Preliminary remarks, mode of operation and construction design Preliminary remarks KRANTZ KOMPONENTEN has developed the Opticlean OC-Q in order to combine in a single product the main features of a ceilingmounted supply air outlet for diffuse indoor air flow, i.e. high level of thermal comfort unobtrusive integration into the suspended ceiling low amount of dirt accumulated on the ceiling low sound power level and low pressure drop. If the Opticlean is installed near a wall or in a room corner, it is possible to alter the discharge direction by using segment covers in order to avoid air draughts in the occupied zone. 1 The Opticlean from KRANTZ KOMPONENTEN is suitable for use in suspended ceiling systems. In grid ceilings with modules of 6 x 6 mm or 600 x 600 mm, the standard design can be laid from above onto the T-bars of the ceiling system, instead of ceiling tiles, and connected to the supply air ductwork. Another square standard design 1) is available for integration into gypsum board ceilings. Further, there are special solutions for a number of other quite common ceiling systems, e.g. metal tile ceilings with clip-in or layin tiles; these solutions are tailored to the specific ceiling systems. Figure 1: Air flow pattern of the Opticlean As standard the outlet faceplate has round perforations with diagonal pitch; the hole diameter is.8 mm, the pitch. mm. This perforation pattern corresponds to the typical appearance of usual metal tiles for ceiling systems. Thus, the integration of this air outlet into the ceiling is unobtrusive. If the perforation pattern of the ceiling tiles is the same, it is hardly possible to distinguish the Opticlean within the ceiling. The Opticlean can be used with other perforation patterns, but this requires technical clarification with our product specialists. Application For ceiling heights. to. m Maximum temperature difference between supply and indoor air: ± K ) Volume flow rate range from 11 to 39 l/s [ to 860 m 3 /h] Also usable as return air inlet Mode of operation The supply air flows very evenly through the perforated faceplate and spreads radially and horizontally. As the supply air induces indoor air, the flow velocity and the temperature difference between supply and indoor air decrease rapidly; this results in a comfortable thermal environment with low indoor air velocities and even indoor air temperatures in the occupied zone. Figure : Air flow pattern made visible by smoke tracer Construction design The Opticlean is available in 7 sizes. It consists of the square air distribution element 1 which is fixed to the perforated faceplate. The underside of the air distribution element has a black coating. The outlet is connected to the supply air ductwork either directly by a flexible duct (connection type O) or via a connection box 3 (connection type K) which can be optionally fitted with a volume flow damper adjustable at the connection spigot. For -way or 3-way discharge, the upper side of the perforated faceplate will be fitted with segment covers 6 made of acoustic fleece. 6 6 6 -way discharge 3-way discharge -way symmetric discharge -way asymmetric discharge Figure 3: Alteration of discharge direction by use of segment covers www.krantz.de DS 136 p. 06.13 The induced indoor air does not come into contact with the perforated faceplate because a layer acting as an air cushion forms under the air outlet. This is why far less dirt accumulates on the ceiling than is the case with turbulent-flow outlets. 1) For Opticlean with circular faceplate, see brochure ref. DS 17 ) When heating, + K up to 3 m ceiling height, + K up to. m ceiling height

Construction design and dimensions For integration into a gypsum board ceiling, the faceplate is turned out on two opposite sides and laid onto the mounting frame for gypsum board 7 which has already been inserted into the ceiling cutout from above and fixed using four drywall screws 8. The joint between the frame and the gypsum board panel shall be filled at the client s expense and later painted to the desired colour together with the ceiling. The faceplate is centred by means of eight spacers 9; this enables to get a regular joint between the mounting frame and the faceplate. This design is basically used for 1. mm thick gypsum board panels 3). Connection type O 1 ø D H 1 R E Figure : Opticlean with mounting frame for gypsum board ceiling Connection type K 3 L Detail of mounting frame ø D H A ø 3. E E 1 A 7 E 1 + 67 E 1 + 87 Section A-A 8 7 B E 1 E 9 1 1. www.krantz.de DS 136 p. 3 06.13 Size 1) Supply air flow rate Grid modules E E 1 1) ø D H 1 ) H L B 6 W in kg Connection type l/s m 3 /h mm mm mm mm mm mm mm mm O K 1 11 31 1 1 79 190.1 70 18 7 6 170 6 99 0 16 180. 3.1 3 600x600 9 8 69 0 6x6 6 31 1 60 190.6 3.6 0 36 119 1 391 19 3 80 3.1.6 0 161 180 80 91 199 390 3 6 80 3.7.7 600 7 39 70 860 600x600 9 91 9 0 31 3.0 6.7 6 7 39 70 860 6x6 6 616 9 0 31 3. 6.9 Figure : Dimensions Filler Gypsum board panel E 1 + 3 Ceiling cutout E 1 + 13 Key 1 Air distribution element 6 Segment covers (made of acoustic fleece) Perforated faceplate 7 Mounting frame for gypsum board 3 Connection box 8 Drywall screw TN 3. x (by others) Connection spigot 9 Spacer Volume flow damper 1) The design for integration into gypsum board ceilings is not available for size 6 ) The total height is based on a minimum bending radius of R/D = 0.. Smaller radii are allowable depending on the type of flexible duct used. 3) Mounting frame for other thicknesses of gypsum board panels on enquiry 3

Design specifications Figure 8: Opticlean for connection to a flexible duct or 90 elbow Figure 6: Opticlean installed in a grid ceiling Figure 9: Opticlean with connection box Figure 7: Opticlean installed in a gypsum board ceiling Design specifications Return air inlets The Opticlean is mainly designed for supply air distribution. It is also possible to use it for return air extraction, but then it is not protected from dirtying (no clean function). This is in particular true when installed in rooms with higher particle load (e.g. corridors, smoking area, etc.). Connection types The outlet connection to the ductwork is possible via a flexible duct or a 90 elbow (Figure 8) or a connection box (Figure 9). The connection box option is recommended in particular when a volume flow damper is required. As a rule, this connection type is louder by about 3 db(a) ref. -1 W than the flexible duct connection at the same air flow rate. With connection box the space requirement in height is less than with direct flexible duct connection. The values are given in the table of dimensions. For installation in false ceilings with very low plenums, the solution is to use a very flat connection box 1). As standard, the Opticlean diffusers are designed for use with metal ceiling tiles having a thickness of 0.6 mm ) and fitted with round perforations.8 mm in diameter with diagonal pitch of. mm. Their mode of operation has been optimized for use with such ceiling tiles. Basically, they can also be used with other ceiling tiles, but then the air flow and acoustic data are likely to differ. It is recommended not to use the Opticlean with ceiling tiles thicker than 0.6 mm and perforations smaller than mm. For such configurations a technical check should be made by our product specialists. www.krantz.de DS 136 p. 06.13 1) More information on enquiry ) Without powder coating or paint

Design specifications There are adequate solutions for most common metal ceiling tiles. Further, special sizes (170, 0 and 3) are available. Technical data can be provided on request. c) In narrow spaces (e.g. corridors) we recommend a segment cover as shown in Figure 1. Minimum air outlet centre spacing When designing the ventilation system, the minimum air outlet centre spacing given in Graph is to be taken into consideration. The spacing shall be halved for outlet placement near a wall. Wall Wall If the space configuration does not make it possible to comply with the minimum centre spacing, the Opticlean outlets can be fitted with segment covers which will enable to reduce the air flow rate by % or %. Figure 1: Segment cover for narrow spaces, for instance a) The segment cover in Fig. is for 3-way discharge d) If the Opticlean is placed in a room corner, the segment cover should be as shown in Figure 13. Wall Wall Wall Figure : 3-way discharge in front of a wall b) If the specified minimum centre spacing between two outlets cannot be complied with, we recommend an arrangement as shown in Figure 11. Figure 13: Segment cover for asymmetric discharge, e.g. for outlet placement in a room corner www.krantz.de DS 136 p. 06.13 a 0. t min value under minimum centre spacing Figure 11: Position of segment cover when the outlet spacing is under the minimum value

Comfort criteria Comfort criteria 1) The outlet layout must comply with the maximum allowable indoor air velocities u in the occupied zone in the cooling mode. The indoor air velocity depends on the cooling load that is to be removed from the room. The maximum specific cooling capacity q depends on the discharge height and the maximum allowable indoor air velocity u (Graph 1). Graph 1 enables to determine for the cooling mode the maximum specific volume flow rate V Sp max in relation to the maximum specific cooling capacity and the maximum temperature difference DJ max. The volume flow rate supplied to the room V Sp tats may not exceed this value. Graph enables to determine the minimum centre spacing between two outlets on the basis of the maximum specific volume flow rate. Temperature difference max 8 K K 0 0 1 1 0 Maximum specific volume flow rate V Sp max in l/(s m ) Maximum specific cooling capacity q in W/m Discharge height H in m.7 0 0 0 0.1 0. 0.3 0.3 Maximum allowable indoor air velocity u in m/s Graph 1: Maximum specific volume flow rate Key for layout: V A = volume flow rate per air outlet in l/s V A max = max. volume flow rate per air outlet when cooling in l/s V A min = min. volume flow rate per air outlet when cooling in l/s V Sp max = max. specific volume flow rate per m in l/(s m ) V Sp tats = actual specific volume flow rate per m of floor area in l/(s m ) u = max. allowable indoor air velocity in m/s q = max. specific cooling capacity in W/m DJ max = max. temperature difference supply air to return air in K t min = minimum air outlet centre spacing in m H = discharge height in m L WA = sound power level in db(a) ref. -1 W Dp t = total pressure drop in Pa Layout example Size 0 Application Office building 1 Supply air volume flow rate V l/s 666 Discharge height H m.7 3 Floor area A m 1 Maximum allowable sound power level L WA db(a) ref. -1 W 38 Temperature difference DJ max K 6 Comfort criteria Maximum indoor air velocity u m/s 0, Maximum specific volume flow rate V Sp max l/(s m ) Actual specific volume flow rate V Sp tats l/(s m ) [from 1 : 3] 6 Criterion is met if V Sp tats < V Sp max From nomogram 7 V A max l/s 111 8 Z [³ V : V A max] units 6 9 V A [V : Z] l/s 111 L WA db(a) ref. -1 W 36 11 Dp t Pa 1 t min [Graph ] m 3.3 Minimum air outlet centre spacing t min in m 6 3 1 0 1 0 Air outlet volume flow rate V A in l/s Max. specific volume flow rate V Sp max in l/(s m ) 7 8 9 1 1 16 18 1) See our brochure ref. TB 69 Layout specifications for thermal comfort www.krantz.de DS 136 p. 6 06.13 Graph : Minimum air outlet centre spacing 6

Layout sheet Opticlean Supply air outlet Opticlean used as return air inlet Total pressure drop p t in Pa Total pressure drop p t in Pa Flexible duct connection 1) 70 80 Size 3 Size 3 Size 0 1 0 Size 0 Size 0 Size 0 Size 600 Size 6 Size 600 and 6 1 0 l/s 0 0 0 0 0 0 m 3 /h 900 Air outlet volume flow rate V A Connection box Size 3 Size 0 Size 0 0 Size 600 and 6 Sound power level L WA in db(a) ref. -1 W Total pressure drop p t in Pa Total pressure drop p t in Pa Flexible duct connection 0 17 0 80 17 0 0 0 60 0 0 0 0 0 m 3 /h 900 Connection box 1 Size 3 Size 3 Size 0 Size 0 Size 0 Size 0 Air inlet volume flow rate V A Size 3 Size 0 Size 0 Size 600 Size 6 Size 600 and 6 Sound power level L WA in db(a) ref. -1 W l/s 0 Size 600 and 6 www.krantz.de DS 136 p. 7 06.13/1 6 1 0 l/s 0 Size 3 Size 0 Size 0 Size 600 and 6 1 0 l/s 0 0 0 0 0 0 m 3 /h 800 Air outlet volume flow rate V A Notes: Sound power levels related to octave band centre frequencies are available on request. The above-mentioned values for sound power level and pressure drop apply to the standard design. The faceplate design has an effect on the outlet operation and its technical features. Where necessary, the suitability of other faceplate designs is to be confirmed by tests. Sound power level L WA in db(a) ref. -1 W 17 0 Size 3 Size 0 17 0 Size 0 Size 600 and 6 0 l/s 0 60 0 0 0 0 0 m 3 /h 900 Air inlet volume flow rate V A 1) With a straight duct, the sound power level is lower by db(a) ref. -1 W Sound power level L WA in db(a) ref. -1 W 7

Features Features High level of thermal comfort thanks to diffuse indoor air flow For insertion into suspended ceiling systems with grid modules of 600 or 6 mm Also suitable for installation into 1. mm thick gypsum board ceilings if fitted with additional mounting frame 1) Perforated square faceplate round perforations with diagonal pitch Rd.8 /. ) coated to RAL 90, gloss Can be laid onto perforated ceiling tiles (for specific projects, on enquiry) Steady radial air spread Very uniform air discharge; as a result, no or extremely low amount of dirt accumulated on the ceiling For ceiling heights. to. m Large volume flow rate range: from 11 to 39 l/s [ to 860 m³/h] 7 sizes available: 1, 70, 3, 0, 0, 600 and 6 Maximum temperature difference: ± K 3) Also usable as return air inlet Low sound power level and low pressure drop Optional segment covers available for placement near a wall or in a room corner Suitable for direct connection to a flexible or straight duct, or fitted with a connection box Connection box optionally available with volume flow damper adjustable at the connection spigot Air outlet element and connection box made of galvanized sheet metal 1) Except for size 6; other gypsum board thicknesses subject to enquiry ) Other perforation patterns on enquiry 3) When heating, + K up to 3 m ceiling height, + K up to. m ceiling height www.krantz.de DS 136 p. 8 06.13 8

Type code and tender text Type code Tender text OC / / _ Opticlean Geometry Geometry Q1 Q QG Size Size Segment cover Connection type Damper Surface finish = square faceplate for square tile ceiling 600 mm x 600 mm = square faceplate for square tile ceiling 6 mm x 6 mm = square faceplate with mounting frame for 1. mm thick gypsum board ceiling (except for size 6) 1) 1 = size 1 0 = size 0 70 = size 70 600 = size 600 3 = size 3 6 = size 6 0 = size 0 Segment cover ) 0 = none (-way discharge) 1 = 3-way discharge = -way symmetric discharge 3 = -way asymmetric discharge Connection type O = no connection piece (only outlet element) 3) K Damper O S = connection box = no volume flow damper = with volume flow damper adjustable at spigot _/0 _/1 _/ _/3 units Opticlean Supply air outlet with horizontal discharge for insertion into suspended ceiling systems with grid modules of 6 x 6 mm and 600 x 600 mm or for integration into 1. mm thick gypsum board ceilings, designed to generate a high-quality indoor air flow at low velocities and uniform indoor air temperatures; unobtrusive integration into the ceiling; extremely low amount of dirt accumulated on the ceiling thanks to very uniform air spread and the resultant air cushion. Outlet consisting of: square faceplate fitted with round perforations with diagonal pitch, hole diameter.8 mm, pitch. mm; where applicable, with mounting frame for integration into a 1. mm thick gypsum board ceiling 1) ; optional segment covers to enable 3-way or -way discharge; air distribution element with top connection spigot for connection to a flexible or straight duct; optional connection box with lateral connection spigot as well as suspension brackets, optionally fitted with volume flow damper adjustable at the connection spigot. Material: Faceplate made of galvanized sheet metal powder coated to RAL. Mounting frame made of galvanized sheet metal Air distribution element made of galvanized sheet metal Connection box made of galvanized sheet metal Make: Type: KRANTZ KOMPONENTEN OC Q_ / / _ www.krantz.de DS 136 p. 9 06.13 Surface finish 90 = face painted to RAL 90, semi-matt. = face painted to RAL. Subject to technical alterations. 1) On enquiry also available for other gypsum board thicknesses ) If nothing is specified, the outlet will be supplied without segment cover. The segment covers serve to reduce the volume flow rate. 3) For direct connection using a flexible duct or 90 elbow 9