JH Series Installation

Similar documents
LV Installation Manual

LV Installation Manual

Parts List * October 2013

Mini Duct Heating and Air Conditioning Indoor Air Quality Systems. July Featuring: Also Including: Lo-Velocity Systems JH Fancoils

Featuring: Small Duct High Velocity Heating, Cooling and Indoor Air Quality Systems

R Series Cooling Manual

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

ESP. Variable Speed Heat Pump. Installation and Operation. 3 Ton ESP Ton ESP-60

R Series Cooling Modules

RCM Refrigerant Module

R Series Cooling Modules

INSTALLATION INSTRUCTIONS

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

SKYPAK II, 3 Ton Series, gives you a

MACH N-407 Heat Pump Air-Cooled Chiller

Commercial Applications

SKYPAK II, 3 Ton Series, gives you a

HE-B Series Commissioning Report & User Guide

Modular Supply Make-Up Air Unit

Vertical Air Handler Unit

MAC N-407 Air-Cooled Chiller

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

HVAC Mandatory Provisions Part II, Page 1

HV to HE Conversion Kit Installation

SpaceKeeper Console (SKC)

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER (USA)

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

DCG Commercial. Submittal Data Form

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

FEATURES AND BENEFITS

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

INDOOR, SUSPENDED, STEAM OR HOT WATER HYDRONIC UNIT HEATER FOR VERTICAL OR HORIZONTAL CONFIGURATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

VERTICAL FAN COIL UNITS

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

Installation, Operation and Service Manual

AHU INSTALLATION & OPERATION MANUAL

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

Product Specifications. Vertical Floor Consoles By First Co.

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

Hydronic Air Handler Powered by Tankless Technology

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Vertical V*B Series Fan Coil Technical Catalog

Direct Gas-Fired Make-Up Air

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

B SERIES ELECTRIC FURNACE

CM R-410A High Efficiency Water Source Heat Pump

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

INSTALLATION & OPERATIONS MANUAL

VariCool VAV Engineering Guide

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

FLOW-THROUGH FURNACE HUMIDIFIER

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

FAS Fresh Air Supply Units

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

Hydronic Air Handler Powered by Tankless Technology

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

INSTALLATION, BALANCING & MAINTENANCE

Gas-Fired Indoor and Outdoor Duct Furnaces

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

Technical Assignment 3 11/15/04. Executive Summary

Direct Fired Heater Model AD Specification

Split Type System. Air to Water Heat Pump

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

10-year industry best core warranty. 5-year warranty on balance of unit.

City of Duluth Festival Center 04/25

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

MAC-120HE-03 Air-Cooled Chiller

Product Data. Features/Benefits. AIRSTREAM 42WKN08-36 Hydronic Ceiling Cassettes

Safety & Installation Instructions

MODEL CDB8 INSTALLATION INSTRUCTIONS

Field Start-Up Sheet Direct Fired Gas Equipment

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Hydronic Air Handler Powered by Tankless Technology

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER

AirPurification System

Transcription:

JH Series Installation Space Heating / Fresh Air Make-Up From the Manufacturers of Hi-Velocity Systems TM Includes: JH-15 JH-30 Module-JH-Series-Installation-Manual-010118

Installation JH fan coils by Energy Saving Products Ltd. can be installed in the Hi-Boy, Horizontal, or Counterflow positions. The JH fan coil can also be positioned on its side for between the joist locations. Return air (Intake Air) access can be from the rear of the unit (Standard), or optionally from the side access panel that is opposite from the motor access. The JH fan coil comes complete with filter and filter frame. When used for fresh air make-up in radiant only systems, the JH fan coil can be used either with or without return air to temper the outside air. The fresh air intake must be insulated and vapour barriered, with a balancing damper installed. A humidifier can also be installed on the JH fan coil. When used for humidification, the humidifier can be mounted on the back access panel. When used for heating, the JH fan coil can be used with a line volt thermostat to operate the fan. This would be used when there is a constant flow of hot water to the JH fan coil. An optional 24 volt relay or circuit board may be installed to operate the unit from a 24 volt thermostat, and to control boiler operation. Hydronic connections are 3/8 I.D. copper sweat connections, and should be piped to allow access to the filter and motor access panel for maintenance and service. Optional Equipment Variable Speed Controller - This allows the airflow to be adjusted to meet exact system requirements. This is especially important when using the JH fan coil for fresh air make-up, as over ventilating a structure will cause excessive fuel usage, and possibly create positive pressure problems within the structure. Low Temperature Cut-Out - When the discharge air temperature drops below 50 F, this control will shut down power to the blower and to the fresh air damper motor (if installed). This control is located in the supply air duct work, within eighteen inches of the fan coil. The disc will automatically reset when the ambient temperature around the disc reaches 60 F. Module JH JH Series Manual (2/10) Low temperature Cut-In - This control is located in the air stream and wired parallel with the rest of the boiler controls running back to control the firing of the boiler. Winter Pump Control - The sensor for this control will be located outside the structure or inside the fresh air duct to allow constant water circulation to the fan coil when the outdoor temperature drops to the setpoint temperature. See page 7 for cut-in temperature settings. Fan Center Relay - This Relay/Transformer combination allows the fan coil to operate with a 24 volt thermostat providing on/ off operation of the fan and/or 24 volt controls. (eg: 24 volt zone valve or damper motor.) Fresh Air Damper Box - This consists of an insulated return air box, with a normally closed, line volt damper. A Low Temperature Cut-Out must be used in conjunction with this damper box to cut power to the damper motor when there is a low discharge air temperature from the fan coil. A filter frame and a six inch round intake collar are standard on this damper box. R/A and S/A Collars - When using round duct work with the JH fan coil, square to round transitions may be ordered from the factory. Transitions are available to either six inch or eight inch round. Directional Discharge Vanes - When using the fan coil for area heating in an exposed application such as an overhead style heater, these vanes may be installed to direct the airflow as needed. Balanced Ventilation Exhaust Unit - When using the JH fan coil for fresh air make-up, a central exhaust ventilator can be interlocked with the fan coil to provide a balanced ventilation system. These JH-xx EX units come with six inch discharge and eight inch intake transitions. Domestic Water Package (DHW) - When used with open potable water systems, the water must be circulated once per day to prevent stagnation during the summer months. Our DHW package includes a Printed Circuit Board with timer chip, transformer, and bronze body circulator pump. JH Series Northern Pak (JH-xx NP) - The JH Series of fan coils can be ordered as a fresh air make-up package by adding the suffix NP to the model number. The Northern Pak consists of: Constant Temperature Controller - This control will provide a constant discharge air temperature by modulating the water flow through the coil. The controller body is installed in the hydronic supply line, and the remote sensor will mount in the discharge air duct within eighteen inches of the fan coil. The control head may then be adjusted to provide the desired leaving air temperature. Isolation Hanging Straps - The JH fan coil can be suspended in any position, using most industry standard hanging support systems. Redi-Rod, All Thread, C-Channel or Unistrut are some of the building code acceptable hanging systems. Use these in conjunction with spring or rubber isolators to ensure a sturdy hanging support system. These isolators will absorb most of the vibrations generated by the fan coil system, eliminating any sound transfer. Fan Coil Filter and Filter Frame Isolation Hanging Straps Low Temperature Cut-Out Variable Speed Controller 1/2 Constant Temperature Controller NOTE: The Northern Pak can be ordered with the Fresh Air Damper Box by using the Suffix NPF. Eg. JH-xx-NPF -2-

JH Heating Unit Dimensions - All Dimensions in Inches - All Dimensions +/- 1/8 - Cabinet finish is Polyester Powder Coat (Sky White) - All Specifications subject to change without notice JH-15/30 NPF Typical Connections -3-

R BL WH BK Y M LEGEND Factory 24v Wiring Field 24v Wiring Factory 10v Wiring Field 110v Wiring Red Blue White Black Yellow Motor JH Fan Coil with On/Off Operation from Printed Circuit Board Timer Jumper Setting Detail Note: Timer set to the on position will activate the circulator pump for five minutes per day to prevent stagnation during the warmer season. -4-

R BL WH BK Y M P C-1 C-2 LEGEND Factory 24v Wiring Field 24v Wiring Factory 10v Wiring Field 110v Wiring Red Blue White Black Yellow Motor Pump Freeze Stat Outdoor Pump Cut-In Line Volt Wiring with Constant Pump Circulation and Variable Speed Option 24 Volt Operation with Freeze Stat Protection and Outdoor Pump Cut-In Controls (Optional) JH Wiring with Line Volt T Stat (Space Heating) -5-

R BL WH BK Y M P C-1 C-2 LEGEND Factory 24v Wiring Field 24v Wiring Factory 10v Wiring Field 110v Wiring Red Blue White Black Yellow Motor Pump Freeze Stat Outdoor Pump Cut-In JH Packaged Make-Up Air Wiring with Circuit Board C-2 Cut-In Settings Based on Percentage of Air Introduced % F/A 100 80 60 40 20 Deg. F 55 50 45 35 10 Timer Jumper Setting Detail Note: Timer set to the on position will activate the circulator pump for five minutes per day to prevent stagnation during the warmer season. -6-

JH EX Series Exhaust Air Units JH-xx EX units can be used as stand alone central exhaust ventilators, or in conjunction with a fan coil for fresh air makeup to provide a balanced ventilation system. Typical installations will have an intake from each bathroom and an intake from the kitchen running to the unit with a six inch exhaust to outside. Manual dampers are recommended to be installed on each duct run to assist in system balancing. A variable speed fan control will be used to set the minimum constant ventilation rate for the structure requirements. Override switches such as de-humidistats or bathroom light switches can be wired parallel to the variable speed control to increase the ventilation rate when needed. When interlocked to a fan coil with multiple speeds, an isolation relay may be needed to prevent voltage from being sent to two sets of motor windings at the same time. Exhaust Air Unit Dimensions JH Exhaust Air Unit Typical Connections - All Dimensions in Inches - All Dimensions +/- 1/8 - Cabinet finish is Polyester Powder Coat (Sky White) - All Specifications subject to change without notice -7-

P M C-1 C-2 BL BK R WH Y SW-1 SW-2 SW-3 SW-4 LEGEND Field 24v Wiring Field 110v Wiring Pump Motor Low Temp Cut-Out Outdoor Pump Cut-In Blue Black Red White Yellow Rheostat Light Switch De-Humidistat Timer Switch JH Exhaust Air Unit with Interlock to Printed Circuit Board for Multi-Speed Fan Coil JH Exhaust Air Unit Wiring with Interlock to Make-Up Air Fan Coil JH Exhaust Air Unit Wiring with Optional Switches -8-

Matching Coils Hot Water Coils JH-15/30 Model JH Series Specifications Fresh Air Make-Up and Space Heating JH-15 JH-15 Hot Water Heating EAT 60 F (16 C) EAT 30 F (-1 C) EAT 0 F (-18 C) EAT -30 F (-34 C) Max. BTUH @ 200 F E.W.T. (kw @ 93 C) 14,500 (4.2 kw) 17,500 (5.1 kw) 20,600 (6.0 kw) 23,000 (6.7 kw) Max. BTUH @ 190 F E.W.T. (kw @ 88 C) 13,500 (3.9 kw) 16,500 (4.8 kw) 19,600 (5.7 kw) 22,000 (6.4 kw) Max. BTUH @ 180 F E.W.T. (kw @ 82 C) 12,400 (3.6 kw) 15,400 (4.5 kw) 18,500 (5.4 kw) 20,900 (6.1 kw) Max. BTUH @ 170 F E.W.T. (kw @ 77 C) 11,300 (3.3 kw) 14,400 (4.2kW) 17,500 (5.1 kw) 19,900 (5.8 kw) Max. BTUH @ 160 F E.W.T. (kw @ 71 C) 10,300 (3.0 kw) 13,300 (3.9 kw) 16,400 (4.8 kw) 18,900 (5.5 kw) Max. BTUH @ 150 F E.W.T. (kw @ 66 C) 9,200 (2.7 kw) 12,300 (3.6 kw) 15,400 (4.5 kw) 17,900 (5.2 kw) Max. BTUH @ 140 F E.W.T. (kw @ 60 C) 8,200 (2.4 kw) 11,300 (3.3 kw) 14,300 (4.2 kw) 16,900 (4.9 kw) Max. BTUH @ 130 F E.W.T. (kw @ 54 C) 7,200 (2.1 kw) 10,200 (3.0 kw) 13,300 (3.9 kw) 15,800 (4.6 kw) GPM Flow Ratings (L/s Flow Ratings) 3 (0.19 L/s) 3 (0.19 L/s) 3 (0.19 L/s) 3 (0.19 L/s) Model JH-30 JH-30 Hot Water Heating EAT 60 F (16 C) EAT 30 F (-1 C) EAT 0 F (-18 C) EAT -30 F (-34 C) Max. BTUH @ 200 F E.W.T. (kw @ 93 C) 31,400 (9.2 kw) 38,200 (11.2 kw) 44,900 (13.2 kw) 51,600 (15.1 kw) Max. BTUH @ 190 F E.W.T. (kw @ 88 C) 29,200 (8.6 kw) 35,900 (10.5 kw) 42,600 (12.5 kw) 49,300 (14.4 kw) Max. BTUH @ 180 F E.W.T. (kw @ 82 C) 26,900 (7.9 kw) 33,600 (9.8 kw) 40,300 (11.8 kw) 47,000 (13.7 kw) Max. BTUH @ 170 F E.W.T. (kw @ 77 C) 24,600 (7.2 kw) 31,300 (9.2 kw) 38,000 (11.1 kw) 44,700 (13.1 kw) Max. BTUH @ 160 F E.W.T. (kw @ 71 C) 22,300 (6.5 kw) 29,000 (8.5 kw) 35,700 (10.5 kw) 42,400 (12.4 kw) Max. BTUH @ 150 F E.W.T. (kw @ 66 C) 21,100 (6.1 kw) 26,800 (7.9 kw) 33,400 (9.8 kw) 40,100 (11.7 kw) Max. BTUH @ 140 F E.W.T. (kw @ 60 C) 17,800 (5.2 kw) 24,500 (7.2 kw) 31,200 (9.1 kw) 37,900 (11.1 kw) Max. BTUH @ 130 F E.W.T. (kw @ 54 C) 15,600 (4.6 kw) 22,200 (6.5 kw) 28,900 (8.5 kw) 35,500 (10.4 kw) GPM Flow Ratings (L/s Flow Ratings) 3 (0.19 L/s) 3 (0.19 L/s) 3 (0.19 L/s) 3 (0.19 L/s) Fan Coil Specifications JH-15 JH-30 Max Rated CFM @ 0.12 E.S.P. (L/s @ 30 Pa) 200 (94 L/s) 380 (179 L/s) Voltage 115/1/50/60 F.L.A. 4 amp 115/1/50/60 F.L.A. 4 amp Nominal Operating Amperage 1.5 2.4 Horse Power 1/25 1/12 Motor RPM 1550 1550 Slo-Blo Fuse (AMPS) 2 2 Hydronic Connections Supply 3/8 (9.5mm) 3/8 (9.5mm) Return 3/8 (9.5mm) 3/8 (9.5mm) Supply Air Size Return Air Size Needed 9 x 10 (228mm x 254mm) 10 x 10 (254mm x 254mm) 9 x 10 (228mm x 254mm) 10 x 10 (254mm x 254mm) Shipping Weight (no coil) 25 lbs (11.3 Kg) 30 lbs (13.6 Kg) Fan Coil Size NOTE: All BTUH ratings based on 3 USGPM Length Width Height 22 (559mm) 14 (356mm) 12 (304mm) EAT- Entering Air Temperature BTUH - British Thermal Units per Hour E.W.T. - Entering Water Temperature GPM - US Gallons per Minute L/s - Litres per Second 22 (559mm) 14 (356mm) 12 (304mm) CFM - Cubic Feet per Minute F.L.A. - Full-Load Amperage RPM - Revolutions per Minute E.S.P. - External Static Pressure -9-

WARRANTY Energy Saving Products Ltd. is proud to offer a limited warranty. This warranty applies strictly to the first purchaser at wholesale level and only to the fan coil unit and module. It does not include connections, attachments and other products or materials furnished by the installer. This warranty excludes any damages caused by changes, relocation to, or installation in a new site. This warranty does not cover any defects caused by failure to follow the installation and operating instructions furnished with the fan coil. This warranty does not cover defects caused by failing to adhere to local building codes and following good industry standards. Failure to correctly install the fan coil, or material related to the unit, may result in improper system performance and/or damages and will void this warranty. This warranty does not cover material installed in or exposed to a corrosive environment. This warranty does not cover products subjected to abnormal use, misuse, improper maintenance, or alteration of the product. Using the fan coil and/or module as a source of temporary heating/cooling during construction will void this warranty. A Five (5) Year Limited Warranty is extended on all components in products manufactured exclusively by Energy Saving Products. These components include Motors, WEG Controller, Circuit Boards, Dampers, Zoning Controls, Blowers, Motor & Blower Assemblies, Heating Coils, Chilled Water Coils, and Air Conditioning Coils. Note: If any product is installed in or exposed to a corrosive environment, warranty will be void. A Three (3) Year Limited Warranty is extended on Electric Strip Heaters. Products sold by Energy Saving Products but manufactured by others, will carry the original manufacturer s warranty. TERMS & CONDITIONS Any repair performed under warranty must be approved by Energy Saving Products Ltd. for this warranty to be valid. The liability of Energy Saving Products Ltd. is limited to and shall not exceed the cost of pre-approved replacement parts. This warranty does not cover shipping costs to and from the factory, labor costs or any other cost associated with the installation of the replacement part. Inoperative parts must be returned to Energy Saving Products Ltd. with an ESP RMA Form that includes model, serial number, and a detailed description of the entire problem. Inoperative parts must be returned in testable condition. Should there be multiple consecutive failures of a single part, warranty will not be considered until a contractor has contacted Energy Saving Products Ltd. Technical Department for assistance. Energy Saving Products Ltd. is not liable for any other damages, personal injury, or any other losses of any nature. Follow these steps for Service or Repair: 1. Contact the installer of the product or a licensed service company 2. Contact the distributor 3. Contact Energy Saving Products Ltd. Mon-Fri 8 am 4:30 pm MT 1-888-652-2219 This warranty replaces all other warranties expressed or implied.

Energy Saving Products Ltd, established in 1983, manufactures the Hi-Velocity Systems TM product line for residential, commercial and multi-family markets. Our facilities house Administration, Sales, Design, Manufacturing, as well as Research & Development complete with an in-house test lab. Energy Saving Products prides itself on Customer Service and provides design services and contractor support. For all of your Heating, Cooling and Indoor Air Quality needs, the Hi-Velocity System is the right choice for you! TM Small Duct Heating, Cooling and IAQ Systems Build Smart, Breathe Easy Hi-Velocity HE-Z Fan Coils, Green Technology Phone: 780-453-2093 Fax: 780-453-1932 Toll Free: 1-888-652-2219 www.hi velocity.com