Return loss measurement of fiber optic components

Similar documents
Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Accuracy counts! Sensors with analog output

OZ Optics Limited. Fiber Optic Attenuators. June 2018

Installation Instructions

STT 3000 Series STT250 /150 Surge Protection Device Specifications

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

PRODUCT INFORMATION. SureSense THE SURE WAY TO DETECT ANY OBJECT. Photoelectric Sensors

KNX The worldwide STANDARD for home and building control. KNX Association International

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

Beckhoff short profile

Battery Industry EFFICIENT APPLICATIONS SOLUTIONS

KNX The worldwide STANDARD for home and building control. KNX Association International

Labeling and Identification Products

Weishaupt WKmono 80. The next-generation burner for ratings up to kw. That s reliability

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

DESCRIPTION FEATURES WARNINGS APPLICATIONS

Rain Forest Quick Guide

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

The advantages of closed heating systems. White paper

Photoelectric laser sensors E3C-LDA SERIES. l o n g - d i s t a n c e, a d j u s t a b l e l a s e r b e a m. Advanced Industrial Automation

International standards used locally worldwide ISO/TC 67

CRA24-B3 controlled residential ventilation

micropac. Personal Gas Detection Instruments

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

E-T-A Get Smart With Your Systems

AutoM Click to go to the page. AutoM Auto Shaker Filter

BFD Light Curtains The new choice for cutting edge safety for industrial doors

Expansion vessel in a solar installation. White paper

Detect. React. Benefit. Increase the availability of your plants with SIMATIC Notifier!

Air distribution systems. Air distribution systems for assembly rooms

PTG, SWT Series. Heat Recovery Systems

Advantages of automatic boiler bottom blowdown

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

A revolutionary development designed for expansive and connected living.

Future development of the furniture industry A look at the next 3-5 years

Manusa Automatic. Doors. Safety beyond the Standard. EN16005 Power operated pedestrian doorsets. Safety in use. Requirements and test methods.

STANDARD T6 (200 C) SENSOR CABLE RANGE

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

Compact FREME. flash recovery energy management equipment HEAT TRANSFER SOLUTIONS

International Standards Health Informatics. Audrey Dickerson, RN, MS ISO/TC 215 Secretary


Air and dirt in closed systems

ISO INTERNATIONAL STANDARD. Acoustics Measurement of sound pressure level from service equipment in buildings Engineering method

Signal converters SVE4 Product overview

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

Acterna MTS 5000 e Series OTDR and Loss Test modules

For more information on Tarkett go to

AERO 20 AERO ENGLISH - Operating Instructions

ISO INTERNATIONAL STANDARD. Glass containers Vacuum lug finishes Part 1: General

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

This document is a preview generated by EVS

International Product Compliance and Certifications. Product Safety Consulting, Inc.

Fire-Resistant. Automatic Doors

MVX 2000 Multivariable Pressure Transducer. Specifications 34-SM March Introduction. Proven Sensor Technology. Flow Computer Benefits

OneWireless Gauge Reader WGR400 Series Specifications 34-XY July 2009

ISO INTERNATIONAL STANDARD. Adhesives for thermoplastic piping systems Part 1: Determination of film properties

ISO 7458 INTERNATIONAL STANDARD. Glass containers Internal pressure resistance Test methods

ILNAS-EN ISO :2005

ISO INTERNATIONAL STANDARD. Steel cord conveyor belts Part 4: Vulcanized belt joints

The best in connector value... today, tomorrow and into the future!

Metal Woodprint The natural look

M700-Series Multifunction OTDR

WATER QUALITY - CRITERIA FOR

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

ISO INTERNATIONAL STANDARD

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

ISO INTERNATIONAL STANDARD. Adhesives for thermoplastic piping systems Test method for the determination of thermal stability of adhesives

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

AGREEMENT CONCERNING THE ADOPTION OF UNIFORM CONDITIONS OF APPROVAL AND RECIPROCAL RECOGNITION OF APPROVAL FOR MOTOR VEHICLE EQUIPMENT AND PARTS

Safety requirement compliance for Lasers

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

This document is a preview generated by EVS

CONFORMITY ASSESSMENT - SUPPLIER'S

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

Forum for European Electrical Domestic Safety FEEDS. B. DOME FISUEL

Sýnishorn ISO INTERNATIONAL STANDARD. Geotechnical investigation and testing Field testing Part 3: Standard penetration test

Modulair vilten plafondsy. Modular felt Ceiling system

ISO INTERNATIONAL STANDARD. Footwear Test methods for outsoles Tensile strength and elongation

Drive Technology \ Drive Automation \ System Integration \ Services. Certified and safe Servo drives for potentially explosive atmospheres

Premium freezers combining functionality, elegance and energy efficiency

Dog guide breed. Software application Typically, a dialog box will paper, then press and release the Go the option to cancel the print job.

ELECTRICAL AND INSTRUMENTATION LOOP CHECK (IEC 62382:2006 (EQV)) IRISH STANDARD I.S. EN 62382:2007. Price Code

Certificate of constancy of performance,

BUILD the clinic you ve always imagined.

English version. Central Secretariat: rue de Stassart 35, B Brussels

FF-SG Series. Safety light curtain Compact and low-cost unit

NIM-Response 3.0 NERVE INTEGRITY MONITORING SYSTEM

English version. Alarm systems Terms and definitions

Forum for European Electrical Domestic Safety FEEDS. Residential Electrical Safety How to ensure progress?

HazLoc Essential Guides:

ISO 505 INTERNATIONAL STANDARD. Conveyor belts Method for the determination of the tear propagation resistance of textile conveyor belts

COMMUNICATION SYSTEMS FOR AND REMOTE READING OF METERS - PART 2: PHYSICAL AND LINK LAYER IRISH STANDARD I.S. EN :

E + M III. Suitable for interfaces. up to CATEGORY 4 per EN E197638

Metal Woodprint The natural look

Transcription:

Return loss measurement of fiber optic components Solutions Brief 815-1 How the HP 8153A/HP 81534A measure return loss of fiber optic components? The significance of return loss The introduction of new technologies in optical transmission systems has created the need to adapt measurement techniques for component characterization. In particular, this has been the case since the introduction of singlemode fiber to optical high-speed transmission systems. Special lasers with narrow linewidth have to be used for the transmission (these are known as Distributed Feedback Lasers DFBs). However, the smaller linewidth the more sensative the laser becomes with regard to backreflections. If a system component, such as a connector, reflects too much light back to the transmitter, the modulation characteristics and the spectrum of the laser change. Highspeed systems usually contain many components, hence there is a real danger that multiple reflections will lead to signal distortion and consequently to system failure. In order to ensure the reliable performance of a system it is vital that all optical components are characterized, such as connectors, couplers, switches and detectors. In doing so it is especially important to measure how much light they will reflect back into the fiber. The parameter which quantifies this characteristic is called return loss. In fiber optics, it is common to show optical signals, such as back reflections on a logarithmic scale. The ratio of the input power level and the power reflected by a component under test yields the return loss. High return loss values characterize components with minimum backreflections. These are most suitable for high speed transmission systems. Thus, to optimize the characteristics of optical components it is necessary to know how to measure return loss precisely. The following will first give a description of how return loss measurements are performed and will then provide a dedicated HP solution. Return loss measurement of fiber optic components, HP 8153A/HP 81534A, Solution Brief, Page 1

Design of a return loss test setup With increasing bit rates in high speed optical transmission systems there is more and more pressure to minimize backreflections from connectors and other system components. The following questions should be considered: 1) What return loss values of components are needed to meet the requirements of state-of-the-art transmission systems? 2) What is the measurement range we have to look at? Straight contact connectors provide highly polished glass-to-glass connections which yield a return loss of between 30dB and 45dB. These return loss values are sufficient for digital transmission rates of up to 2.4 Gbit/s. Beyond this transmission rate and also for analog cable TV applications connectors with return loss values better than (larger than) 60dB may be required. These values can only be achieved using angled connectors. Their slanted finish at the fiber end forces backreflections to hit the cladding rather than being coupled back into the fiber core. Because of this the test setup must be capable of measuring return loss values accurately at or beyond 60dB. In order to perform return loss measurements on a device under test the test setup must consist of a laser source, a fiber optic coupler, and a detector (see Figure 1). Configuring the HP 8153A multimeter with the HP 81534A return loss module and one of the laser source modules provides you with a complete solution in one single instrument. Additionally, built-in application software supports the return loss measurement. Criteria for accurate return loss measurements To achieve and ensure accurate measurements of return loss values better than 60dB several conditions have to be met: Firstly, the output power of the laser source has to be highly stable as any power fluctuations will directly add to the measurement uncertainties. Secondly, the laser source output power and the receiver sensitivity must offer enough dynamic range to keep the return loss signal well above the noise level and to display it with resolution good enough even for high return loss values. Thirdly, the photodetector and the amplification circuits must show good linearity over all measurement ranges as linearity errors contribute directly to measurement uncertainty. Movements of the fiber in the test setup change the polarization of the light signal. If the coupler which is used in the test setup shows polarization dependence a change in polarization will cause a changing coupling ratio. This results in a fluctuation of the return loss reading. So in order to optimize the test setup it is very important to use a coupler with a minimal polarization dependence. Finally, unwanted contributions to the measurement results called parasitic reflections - should also be considered (see below). All these requirements were taken into account when the HP 81534A return loss module was designed to meet highest performance expectations. Laser Coupler Test port Customer connector pair (device under test) Signal input Detector Angled connector Backreflection Figure 1, Elements of a return loss measurement Parasitic reflections Termination Return loss measurement of fiber optic components, HP 8153A/HP 81534A, Solution Brief, Page 2

How to perform return loss measurements using the HP 8153A multimeter with the HP 81534 a return loss module? In order to determine the return loss of a device under test three power levels have to be measured: - the power of the backreflection of a known reference reflector attached to the test port (reference measurement) - the power of the backreflections caused by parasitic reflections of the test setup itself - the power of the backreflections when the device under test is attached to the test port The following paragraphs describe and explain the entire measurement procedure in greater detail (see Figure 2). 1) The HP 81000BR is the accessory used to calibrate the setup for return loss measurements. It provides a stable 96% reflection with only 2% uncertainty. An open connector is not a good reference, because its return loss may vary more than ldb (25%) of the 14.6dB reflection, due to the influence of the polishing process. The HP 81000BR reflector has to be attached to the return loss module at the test port, as seen in Figure 2. Then, the appropriate reference value (0.18dB for the HP 81000BR/ 14.6dB when a cleaved fiber is used as a reference) has to be entered as PARAM R by pressing DISP to REF. 2) For the most accurate measurements all additional backreflections caused by the fiber cable or a patchcord in the test set up (called parasitic reflections) must be eliminated. This can be done by terminating the cable close to the front of the test port. Termination can be achieved by bending the fiber into several tight fiber loops. Again, a measurement is made and this value has to be stored as PARAM T by pressing DISP to REF. 3) Finally, the device under test can be connected to the test port. The return loss value of the device under test is automatically calculated and shown on the display. If the device under test is a pigtailed component, then the test port of the return loss module must also be a bare fiber (Option 001). To calibrate this setup, the bare fiber end of the return loss module can be cleaved to provide a 14.6dB reflection. A cleaved fiber end is a precise, repeatable reference for return loss measurements on pigtailed components. A pigtail output extends the measurement range from > 60dB to 65dB (Option 001). The measurement procedure remains the same. To save time during testing and to minimize errors, recalibration should only be repeated if the setup is physically altered i.e. if a patchcord is removed or exchanged. For more information on return HP 81552SM HP 81534A HP 8153A HP 81109AC HP 81552SM Laser Source 1310 nm Active HP 81534A Return Loss Module Output 9/125µm HP 81102BC Output 9/125µm Input Source HP 81101AC Figure 2, Return loss test set configuration HP 81000AI Test port I. Connect reference reflection HP 81000UM, HP 81000AI, HP 81000BR a) b) use cleared fiber end as reference II. Terminate before test port III. Connect DUT a) with appropriate adapter interface to test port b) splice to bare fiber Return loss measurement of fiber optic components, HP 8153A/HP 81534A, Solution Brief, Page 3

For more information, call your local HP sales office listed in your telephone directory or an HP regional office listed below for the location of your nearest sales office. United States of America: 1 800 452 4844 Canada: (905) 206 4725 Japan: (81) 426 48 0722 Latin America: Miami, Florida (305) 267 4245/4220 Australia: (008) 131 347 ext. 2902 Melbourne Caller: (272) 2555 New Zealand: (800) 738 378 Asia Pacific: Hong Kong: (852) 2599 7070 India: (11) 647 2311 Korea: (2) 769 0800 Malaysia: (3) 295 2377 PRC: (1) 505-3888 Singapore: 290 6375 Taiwan: (2) 717 9680 Thailand: (2) 254 6720 Data subject to change Copyright 1993 Hewlett-Packard GmbH Printed in Germany 01/95 (CT) 5963-5344E In Europe, Africa and Middle East, please call your local HP sales office or representative: Austria: (1) 25000-0 Belgium and Luxembourg: (02) 778 31 11 Czech Republic: (2) 474 3457 Denmark: 45 99 10 00 Finland: (90) 88 721 France: (1) 69.82.65.00 Germany: (01 80) 5 32 62 33 Hungary: (1) 252 7220 Ireland: (01) 284 4633 Israel: (03) 5380 333 Italy: (02) 92 122 999 Netherlands: (020) 547 6669 Norway: (22) 73 56 00 Poland: (22) 375 065 Portugal: (11) 301 73 30 Russia: (095) 923 5001 South Africa: (011) 806 1000 Spain: 900 123 123 Sweden: (08) 444 20 00 Switzerland: (01) 735 7111 Turkey: (312) 468 8770 United Kingdom: (01344) 366 666 For countries not listed, contact Hewlett-Packard International Sales Europe Geneva, Switzerland Tel: +41-22-780-4111 Fax: +41-22-780-4770 Return loss measurement of fiber optic components, HP 8153A/HP 81534A, Solution Brief, Page 4