PROTECT SRB 101EXi-1R

Similar documents
PROTECT SRB 200EXi-1A

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Operating Manual MS220KA and MSR220KA

Datasheet - MZM 100 B ST2-SD2PREM-A

Datasheet - MZM 100 ST2-1P2PWREM-A

Datasheet - MZM 100 ST-SD2PREM-A

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Inductive slot sensor

ISIS SAFETY SYSTEM Installation guide

Datasheet - AZM 161SK-12/12RK-024

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Operating Manual MS220DA

SET Installation and Operating Instructions. Level switch for one sensor

Datasheet - AZM 161SK-12/12RK-024

OPTIBAR P 1010/2010 C Supplementary instructions

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 5 mm

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Technical Data. Dimensions

OilSET-1000 (12 VDC)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Datasheet - AZM ZRK 24 VAC/DC

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

Product ID. General. TE CONNECTIVITY SENSORS /// EXxxHyy Ex-Atex & NA 09/2017 Page 1

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

SET-2000 Hi Level/Oil

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

Technical Data. Dimensions

Datasheet - TVS /B-M20

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

AO Annunciator Module

Operating Manual MS220Vi and MSR220Vi

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170

SLC 220 E/R RFBS

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

Original operating instructions Safety switch with guard locking AC901S AC902S

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

FAHM Co. Temperature Transmitter PTT74 Series

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Technical Data. Dimensions

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

VERSAFLOW VORTEX Supplementary instructions

SET-2000 Oil/Sludge 12 VDC

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Technical Data. Dimensions

Snifter ATEX22 VERSION. User Manual. Distributor

RE-PR3-E-27 3-Phase Panel Mount 27kW

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

DICTATOR Hold-Open Systems for Hazardous Areas

Operating Instructions Edition 02/2007

Operating Manual MS220VA and MSR220VA

PEPPERL+FUCHS GmbH

UV Flame Supervision System

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Manual Power relay SR853

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

USB Interface for setup program. 1 analog output standard signal. LCD display with white background lighting. 1 relay output pre-alarm ( KV)

Annubar Flowmeter Series

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

Manual for QX0201 Push Button

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Continuous Gas Analyzers AO2000 Series AO2040-CU Ex Central Unit in Category 2G. Operator s Manual 42/24-13 EN Rev. 3

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Installation and Operating Instruction

Safety. Detection. Control. SAFETY INTERFACES. Safety Interfaces and Relays. Product catalogue. Issue 1

Manual Isolating Barrier D461R1 (Revision 01)

SensaGuard TM Integrated Latch Installation Instructions

Monitoring Relays. 3RN1 Thermistor Motor Protection. For PTC sensors. 7/120 Siemens LV 1 T 2008

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Process Alarm Module RTA 421

Manual Isolating Barrier D461 (Revision 05)

GESTRA. GESTRA Steam Systems NRS For ONE Electrode. English. Installation Instructions Level Switch NRS 1-50

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

INSTRUCTION & SERVICE MANUAL

Temperature Sensor TRG Original Installation Instructions English

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Operating Guide Safe Torque Off

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

Engineering Guideline. pac- Carriers Type Universal

Transcription:

1 BG Забележка Aко не сте прочели тези инструкции, моля свържете се с нашите представители (www.elan.de). IRL Eolas Mura bhfuil tú in ann an lámhleabhar seo a léamh, déan teagmháil lenár bhfochuideachta, le do thoil (www.elan.de) CZ Upozornění Pokud byste si nemohli přečíst tento návod, obraťte se prosím na naše zastoupení (www.elan.de). LT Nuoroda Jei negalite perskaityti šios instrukcijos, prašome kreiptis į mūsų atstovybę (www.elan.de). D Hinweis Sollten Sie diese Anleitung nicht lesen können, wenden Sie sich bitte an unsere Vertretung (www.elan.de). LV Norāde Ja nevariet izlasīt šo instrukciju, lūdzam griezties mūsu pārstāvniecībā (www.elan.de). DK Bemærk Hvis du ikke kan læse denne anvisning, bedes du henvende dig til vores repræsentant (www.elan.de). M Jekk jogħġbok innota Jekk ma tkunx tista taqra din l-istruzzjoni, jekk jogħġbok ikkonsulta mar-rappreżentant tagħna (www.elan.de) E Nota En el caso de que no pueda leer estas instrucciones, p.f. diríjase a nuestro representante (www.elan.de) NL Opmerking Als u deze handleiding niet kunt lezen, gelieve ons te contacteren (www.elan.de) EST Märkus Kui näete seda instruktsiooni moonutatult, palume pöörduda meie esinduse poole (www.elan.de). PL Uwaga Jeśli nie mogą Państwo przeczytać tej instrukcji, prosimy o kontakt z naszym przedstawicielstwem (www.elan.de). F Indication Si vous ne pouvez pas lire cette notice, veuillez vous rendre sur notre site Internet (www.elan.de). PT Nota Se não conseguir ler este manual, contacte a nossa delegação (www.elan.de). FI Huomautus Jos et voi lukea ohjetta, ota yhteys edustajaamme (www.elan.de). RO Indicaţie În cazul în care nu puteţi citi acest manual de utilizare, contactaţi reprezentanţa noastră (www.elan.de). GB NB Should you not be able to read these instructions, please contact our agency (www.elan.de). SE Anmärkning Skulle ni inte kunna läsa denna instruktion, ta vänligen kontakt med vår agentur (www.elan.de) GR Υπόδειξη σε περίπτωση κατά την οποία δεν μπορείτε να διαβάσετε αυτές τις οδηγίες, να απευθυνθείτε στην αντιπροσωπεία μας (www.elan.de). SI Opozorilo Če ne uspete prebrati navodil, se obrnite na naše zastopstvo (www.elan.de). H Javaslat Ha nem tudná elolvasni a kézikönyvet, kérjük, forduljon a képvisletünkhöz (www.elan.de). SK Upozornenie: Ak by ste si nemohli prečítať tento návod, obráťte sa prosím na naše zastúpenie (www.elan.de)." I Nota Nel caso in cui non riusciate a leggere questo manuale siete pregati di rivolgervi alla nostra rappresentanza (www.elan.de).

2 Installation up to zone 1/21 J K B S L1 +24 VDC 0V X1 X2 S11 S12 S21 S22 Installation up to zone 2 A1 F1 F2 U B U EXi U i 0V S12 S11 S21 S22 X1 X2 K1 Logic K2 K1 K2 13 21 K B U EXi SRB 101EXi U B -1R U i K1 K2 PA PA A1 A2 13 14 21 22 A2 PA PA 14 22 K B N Control 2-channel selection shown by way of example of a guard monitoring with two position switches, of which at least one is positively opening; with external reset button J. Power level: 2-channel selection control, suitable for contact amplification or contact multiplication by means of contactor or relay with positive driven contacts. Wire breaks, earth leakages and cross-shorts in the monitoring circuits are detected. S = feedback loop Safety function The safety function is defined as follows: The enabling output 13-14 is open, when the inputs S11-S12 and/or S21-S22 opens. The safety related current path with the output contacts 13-14 fulfil in consideration with a B 10d -value view the following requirements (refer also to Information within the meaning of DIN EN ISO 13 849-1 ): category 4 PL e acc. DIN EN ISO 13 849-1:2007 is equivalent to SIL 3 acc. DIN EN 61 508-2:2002 is equivalent to SILCL3 acc. DIN EN 62 061:2005 (is equivalent to control category 4 acc. DIN EN 954-1:1997) For designation of the performance level (PL) acc. DIN EN ISO 13 849-1:2007 of the whole safety function (e.g. sensor, logic, actor) a view to all relevant components is necessary. Type designation (installation of the sensors up to zone 1/21) Enabling current paths: 1 NO, 1 NC Operating voltage: 24 VDC Order number: 1196283 Approvals: TÜV 08 ATEX 7522, TÜV 08 ATEX 7557X Authorised applications The applicable laws or guidelines for the use or the planned application are to be considered. The safety relay module is for use in: Emergency stop circuits with control devices to DIN EN ISO 13 850:2007, EN 60947-5-5:2005 Guard door monitoring circuits with locking device to EN 1088:2007 Monitoring circuits with electromagnetic safety switches to EN 60 947-5-3:2005

3 Technical data Operating voltage 24 VDC 15%/+20%, residual ripple max. 10% Fuse of the operating voltage Power consumption Switching capacity of the enabling contacts Fuse of the enabling contacts Min. switching capacity Contact resistance internal fuse F1: T 50 ma/250 V internal fuse F2: T 100 ma/250 V max. 3.0 W 230 VAC, 3 A ohmic (inductive with suitable suppressor circuit): AC-15: 230 VAC/3 A DC-13: 24 VDC/3 A 3.15 A slow-blowing min. 10 V/10 ma max. 100 mω in new state Utilisation categories AC-15, DC-13: EN 60 947-5-1:2004 Contact materials/contacts Switching capacity of the auxiliary contacts Fuse of the auxiliary contacts Current and voltage at S11, S12, S21, S22 Current limiting at S11, S12, S21, S22 Pick-up delay time Drop-out delay time Bypass in the case of voltage drops Air clearance and creepage distance AgSnO, self-cleaning, positively driven 24 VDC/2 A 2 A slow-blowing 24 VDC/5 ma 15 ma approx. 20 ms at emergency stop: approx. 20 ms at power failure: approx. 20 ms approx. 15 ms Class of protection housing: IP 40 terminals: IP 20 installation space: IP 54 Cable connections Tightening torque Max. resistance of entire line Cable lengths (at nominal load) Dimensions (h/w/d) Weight IEC 60 664-1:2007 (DIN VDE 0110-1), 4 kv/2 (basic isolation) EN 60 079-11:2007 (VDE 0170/0171 Part 7) 2 Single core: rigid or flexible (with or without wire-end ferrule) 0.25 2.5 mm Dual wire with same cross section: rigid or flexible (with wire-end ferrule without plastics) 0.25 2.5 mm 2 flexible (with or without TWIN wire-end ferrule) 0.5 1.5 mm 2 0.6 Nm 30 Ohm 1-channeled without cross-short recognition: 1.5 mm 2 : 1,500 m; 2.5 mm 2 : 2,500 m 2-channeled with/without cross-short recognition: 1.5 mm 2 : 1,500 m; 2.5 mm 2 : 2,500 m 100 mm/22.5 mm/121 mm approx. 220 g Ambient operating temperature 25 C + 60 C Storage temperature 40 C + 85 C Mechanical life time 10 7 switching cycles Terminal markings EN 60 947-1:2007 EMC EN 60 947-5-1:2004 Oscillations DIN EN 60068-2-6:1996: frequency: 10 55 Hz amplitude: 0.35 mm Environmental conditions DIN EN 60 068-2-78:2002 CE conformity acc. directives MRL: 98/37/EC, EMC: 2004/108/EC, ATEX: 94/9/EC

4 EX-relevant technical data EC type examination/type examination Group, category, type of protection Safety-related maximum current U m Inputs (S11-S12, S21-S22, X1-X3) Temperature class TÜV 08 ATEX 7522 / TÜV 08 ATEX 7557 X gas: L II 3 G Ex nanc IIC T5 (SRB in zone 2) gas/dust: L II (2) GD [Ex ib] IIC / [Ex ibd] (electric circuits in zones 1, 21/2, 22) 253 VAC (Attention: U m is nt rated voltage!) [Ex ib] IIC / [Ex ibd] Max. output voltage U o 33.6 V Current I o 57.0 ma Max. output power P o 478.8 mw (characteristic curve linear) Isolation (intrinsically safe/other circuits) safe isolation acc. EN 60 079-11:2007, voltage peak value 375 V T5 Group, category II C II B External capacitance C o (nf) 26 36 46 49 160 180 230 280 350 412 External inductance L o (mh) 4.0 2.0 1.0 0.5 38.0 5.0 2.0 1.0 0.5 0.2 Reference value of a circuit: C 200 nf/km, L 1 mh/km (C 200 pf/m, L 1 µh/m) Mounting of the sensors The execution of the installation of the intrinsically safe circuits is to be realized according the up-todate European standards EN 60 079-14:2003 or EN 61 241-14:2004. Attention: Acc. to EN 60079-11:2007 the following is to be considered at the installation: The distance of 6 mm between the terminals of the intrinsically safe circuits to other intrinsically safe circuits should be considered. The distance of 50 mm between the terminals of the intrinsically safe circuits to other not intrinsically safe circuits should be considered. Initiation and installation are to be accomplished only by therefore qualified personnel.

5 Special terms for use in zone 2 Installation in Zone 2 The units are to be installed in switching or junction boxes, which consider the terms of EN 60 079-15:2005. The unit may only be installed and operated by personnel who are familiar with both these instructions and the current regulations for safety at work and accident prevention. The intrinsically safe circuits of the unit (light blue terminals) may be layed in explosion-endangered areas. In this procedure there is to pay attention to a safe disconnection to all not intrinsically safe circuits. 5 cm Switching box IP 54 qualified for installation in zone 2 acc. EN 60079-15 5 cm Air about the module approx. 2,400 cm 3 (8.25 16 18.1 cm) Attention: Connecting and disconnecting of contacts of not intrinsically safe circuits under potentially explosion atmosphere is not allowed. The housing may only be cleaned with a wet cloth. The life cycle of the module, relating to the type of protection nc, is at least 15 years. After end of this time the module is to be changed or to be send to the manufacturer for a check-up! 5 cm 5 cm Contactor II 3G Attention: The temperature declarations ( 25 C Ta + 60 C) of the module refer to a minimum volume of the switching box of approx. 2,400 cm 3 per SRB. Make sure you maintain a distance of approx. 5 cm to other sub-assemblies. Terminals (Cl. II 3G) 0V X1 X3 X2 S11 S12 S21 S22 U EXi Potential equalisation Connection of the PA terminals Acc. EN 60079-14:2003 Clause 12.2.4 two conductors with a cross section of at least 1.5 mm 2 may be connected between the terminals PA and the potential equalisation. U B U i K1 K2 SRB 101EXi -1R -1A PA PA A1 A2 13 14 21 22 2 1,5 mm 2

6 Circuit examples X1 J K B X2 Start configuration External reset button (without edge detection) The reset button is connected as shown in series to the feedback loop. The module is activated by resetting (after releasing) the reset button (= detection of the trailing edge). Faults in the reset button, e.g. welded contact or manipulation which could lead to unintended restart are recognised by this circuit leading to operational interruption. The control of the reset button effected over an intrinsically safe circuit. For starting the module the reset button can be executed as simple E- Stop S11 S21 Dual-channel emergency stop circuit with control devices acc. DIN EN ISO 13 850:2007 (EN 418) and EN 60947-5-5:2005 Detects wire breaks and earth leakages in Cross-shorts between the control circuits are not detected. For monitoring the safety circuits the emergency as simple Category 4 PL e acc. DIN EN ISO 13 849-1:2007 reachable (with protected cable laying). E- Stop S11 S12 Single-channel emergency stop circuit with control devices acc. DIN EN ISO 13 850:2007 (EN 418) and EN 60947-5-5:2005 Detects wire breaks and earth leakages in For monitoring the safety circuits the emergency as simple Category 2 PL d acc. DIN EN ISO 13 849-1:2007 reachable. E- Stop S11 S21 Dual-channel emergency stop circuit with control devices acc. DIN EN ISO 13 850:2007 (EN 418) and EN 60947-5-5:2005 Detects wire breaks and earth leakages in Cross-shorts between the control circuits are detected. For monitoring the safety circuits the emergency as simple Category 4 PL e acc. DIN EN ISO 13 849-1:2007 reachable.

7 S11 S12 Single-channel guard monitoring with interlocking devices acc. EN 1088:2007 At least one positively opening contact. Detects wire breaks and earth leakages in For monitoring the safety circuits the emergency as simple Category 2 PL d acc. DIN EN ISO 13 849-1:2007 reachable. S11 S21 Dual-channel control with electromagnetic safety switches acc. EN 60947-5-3:2005 Detects wire breaks and earth leakages in Cross-shorts between the control circuits are not detected. For monitoring the safety circuits the emergency as simple Category 3 PL e acc. DIN EN ISO 13 849-1:2007 reachable. S11 S21 Dual-channel guard monitoring with interlocking devices acc. EN 1088:2007 At least one positively opening contact. Detects wire breaks and earth leakages in Cross-shorts between the control circuits are not detected. For monitoring the safety circuits the emergency as simple Category 4 PL e acc. DIN EN ISO 13 849-1:2007 reachable (with protected cable laying). S11 S21 Dual-channel control with electromagnetic safety switches acc. EN 60947-5-3:2005 Detects wire breaks and earth leakages in Cross-shorts between the control circuits are detected. For monitoring the safety circuits the emergency as simple Category 3 PL e acc. DIN EN ISO 13 849-1:2007 reachable. S11 S21 Dual-channel guard monitoring with interlocking devices acc. EN 1088:2007 At least one positively opening contact. Detects wire breaks and earth leakages in Cross-shorts between the control circuits are detected. For monitoring the safety circuits the emergency as simple Categorie 4 PL e acc. DIN EN ISO 13 849-1:2007 reachable. Attention! It is only admissible to connect electromagnetic safety switches to the analysis circuitry if the requirements of standard EN 60 947-5-3:2005 are satisfied. The following minimum technical requirements must be satisfied: switching capacity: min. 3 W switching voltage: min. 40 VDC switching current: min. 75 ma

8 Simple apparatus The simple electrical apparatus fulfil the requirements of the type of protection Intrinsic Safety (EN 60 079-11, EN 61241-11). Under the listed installation conditions these can be used in the defined explosion-endangered areas. The installation conditions (e.g. EN 60 079-14, EN 61 241-14), the safety designations (national designations too) and the accident prevention regulations must be pointed out. Conditions to intrinsically safe circuits: Only one intrinsically safe circuit may be connected to the module. Make sure that the self-safety of the circuit is not affected. Housings consider at least the protection type IP 54 (EN 60 529) at gas, IP6X at dust (IP5X at not conductive dusts in zone 22). Allowed equipment for use in connection with the module Reset button The following devices can be used as simple apparatus : EX-RDT... (Elan Schaltelemente GmbH & Co. KG) EX-RDM... (Elan Schaltelemente GmbH & Co. KG) Emergency stop control devices The following device can be used as simple apparatus : EX-RDRZ... (Elan Schaltelemente GmbH & Co. KG) Locking devices The following devices can be used as simple apparatus : EX-AZ 16-...-3D (K.A. Schmersal GmbH) EX-AZ 17-...-3D (K.A. Schmersal GmbH) EX-AZ 335-...-3D (K.A. Schmersal GmbH) EX-AZ 355-...-3D (K.A. Schmersal GmbH) EX-AZ 415-...-3D (K.A. Schmersal GmbH) EX-AZ 3350-...-3D (K.A. Schmersal GmbH) EX-Z/T 235-...-3D (K.A. Schmersal GmbH) EX-Z/T 335-...-3D (K.A. Schmersal GmbH) Safety magnet switches The following devices can be used as simple apparatus : EX-BN 20-...-3G/D (K.A. Schmersal GmbH) EX-BNS 33-...-3G/D* (K.A. Schmersal GmbH) EX-BNS 120-...-3G/D * (K.A. Schmersal GmbH) EX-BNS 180-...-3G/D (K.A. Schmersal GmbH) EX-BNS 303-...-3G/D* (K.A. Schmersal GmbH) * without LED version Installation instructions Application area acc. ATEX directive: Category 2G, 3G: Usage in gas explosion-endangered areas of the zones 1 and 2 Category 2D, 3D: Usage in dust explosion-endangered areas of the zones 21 and 22 For reset buttons, emergency stop control devices, locking devices and safety magnet switches: Technical data in the intrinsically safe circuit: voltage U = 40 V i current I = 75 ma i capacity C = 0 µf i inductivity L 0 mh i temperature class T6 Cable or conductor entry: cable outer diameter: 7 12 mm The cable or conductor entry is made for stationary laying of the cables or conductors.. The cable or conductor entry is to be mounted with a tightening torque of 10 14 Nm (reference value). Cables/conductor (exemplary): The cable or the conductor are layed mechanically protected. The cable or the conductor are to lay separated of other not intrinsically safe circuits. For reset buttons and emergency stop control devices additional: Mounting box EX-EBG 331.0 (Elan Schaltelemente GmbH & Co. KG) Mounting box EX-EBG 633.0 (Elan Schaltelemente GmbH & Co. KG) Mounting of the mounting box: Mounting is only allowed in the mounting boxes EX-EBG 331.0 or EX-EBG 633.0. In the case of using the mounting box EX-EBG 633.0 the third borehole is to be plugged with the plug for the control device entry EX-MBN. The installation is to be done acc. the instructions for EX-RDT or EX-RDM. The housing or the button may not be earthed. Attention! Only one intrinsically safe circuit may be connected to the module.

9 +24 VDC L1 N S X1 X2 13 21 14 22 Control unit Actor configuration Single-channel control with feedback loop Suitable for contact amplification or contact multiplication by means of relays or contactors with positively opening contacts. If the feedback is not required it is to be replaced by a bridge. Attention: Acc. to EN 60079-11:2007 the following is to be considered at the installation: The distance of 6 mm between the terminals of the intrinsically safe circuits to other intrinsically safe circuits should be considered. The distance of 50 mm between the terminals of the intrinsically safe circuits to other not intrinsically safe circuits should be considered. S = Feedback loop +24 VDC L1 N K B S X1 X2 13 21 K B 14 22 Control unit Actor configuration Dual-channel control with feedback loop Suitable for contact amplification or contact multiplication by means of relays or contactors with positively opening contacts. If the feedback is not required it is to be replaced by a bridge. Attention: Acc. to EN 60079-11:2007 the following is to be considered at the installation: The distance of 6 mm between the terminals of the intrinsically safe circuits to other intrinsically safe circuits should be considered. The distance of 50 mm between the terminals of the intrinsically safe circuits to other not intrinsically safe circuits should be considered. S = Feedback loop Function description The is a dual-channel safety relay module for the monitoring of emergency stop control devices, guard monitoring and safety magnet switches. In the case of closed protection circuits S11-S12 and S21-S22 and closed feedback loop X1-X2 the module starts up after activating and releasing and close the enabling path 13-14. By actuation of the emergency stop control device or an other protection device the enabling path 13-14 will be opened directly. Via the signalling path 21-22 e.g. an external control can be signalized the switching condition of the. The module can be restarted when both internal relays K1 and K2 have been dropped out. Data within the meaning of DIN EN ISO 13 849-1:2007 B 10d value (for one channel) with low load: 20,000,000 with maximum load: 400,000 DC (internal error detection) 99% (high) CCF > 65 points Conversion in MTTF d : refer to DIN EN ISO 13 849-1:2007 Annex C Item C.4.2 MTTF d = B 10d n = d h 3,600 s/h op op op 0.1 n op t cycle d op = average number of operating day per year h op = average number of operating hours per day t cycle = average request of the safety function in s (for example 4 per hour = 1 per 15 min. = 900 s)

10 0V X1 X2 S11 S12 S21 S22 U EXi U B U i K1 K2 SRB 101EXi -1R PA PA A1 A2 13 14 21 22 Opening of the front cover To open the front cover insert a slotted screw driver in the lower and upper recess of the cover and lift it slightly. If the front cover is removed, the regulations for ESC have to be complied. After adjustment the front cover has to be replaced. Attention! Don t touch before discharge! Adjustment of the switch Programming to function cross-short recognition (, = delivery status) effected by the switch under the front lid of the module. Operating the switch is only allowed in free from tension condition mit the finger or a blunt isolated tool. Pos. (top): Not cross-short safe, applicable for singlechannel applications and applications with non-floating outputs in Pos. (bottom): Cross-short safe, applicable for dual-channel applications without non-floating outputs in LED functioning K1 Status channel 1 K2 Status channel 2 U B Status internal power supply (LED lightening when power supply is connected to terminal A1-A2) U i Status internal power supply (LED lightening when power supply is connected to terminal A1-A2 and internal fuse F1 is okay) U EXi Status internal power supply (LED lightening when power supply is connected to terminal A1-A2 and internal fuse F1 is okay) Maintenance Service The module is servicing-free. The module has to be integrated into the periodic check-ups acc. to Betriebssicherheitsverordnung/ATEX-Betreiberrichtlinie (99/92/EG) (at least 1 per year). Emergency maintenance Modifying of modules, which are connected to explosion-endangered areas, is not allowed. Repairing of this modules is also not allowed.

11 Mounting The housing will be attached into the DIN rail with the rear side up, slightly tilted forward and pushed above until locked. Dismantling Push the rear side of the relay up; tilt forward and demount. 122 (121 without BMK) 22.5 100 EXi circuits (light blue) non-exi circuits (grey) DIN rail acc. EN 60715:2001

12 K.A. Schmersal GmbH Phone: +49 (0)202 6474-0 Industrielle Sicherheitsschaltsysteme Facsimile: +49 (0)202 6474-100 Möddinghofe 30, D-42279 Wuppertal E-Mail: info@schmersal.com P.O. Box 24 0263, D-42232 Wuppertal Internet: www.schmersal.com Production site: Elan Schaltelemente GmbH & Co. KG Phone: +49 (0)641 9848-0 Im Ostpark 2, D-35435 Wettenberg Facsimile: +49 (0)641 9848-420 P.O. Box 1109, D-35429 Wettenberg E-Mail: info@elan.schmersal.com Internet: www.elan.de 1203576 470/08 02.06.08