Connector Maintenance

Similar documents
FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

Extensive range of models covering all telecom testing applications. Flexible design, allowing up to three wavelengths in a single module

Best Practice Briefing

Fiber Optic Connector Cleaning and Inspection Kit Instructions

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

Keysight 81663A DFB Laser Source Module

Keysight Cleaning Procedures for Lightwave Test and Measurement Equipment

Cleaning of fiber optic connectors

MicrOTDR. Optical Fault Locator. User Manual

Cleaning Instructions for Symbol IP54 Devices

The True Value of Connector Inspection: New Challenges and Best Practices

White Paper: Fiber Contamination, Cleaning and Inspection. Introduction.

Applications Engineering Notes

White Paper Fiber optic connections: check and clean first, then connect!

Agilent 81591B, 81594B, 81595B Optical Switches User's Guide

MT-RJ Optical Fiber System Field Testing

MOST EFFECTIVE METHOD FOR WIPING A FIBRE

LAN/WAN OTDR FTB-7200 FTTx Access/Metro OTDR FTB-7200/7300 Metro/Long-Haul OTDR FTB-7400/74000 Long-Haul OTDR FTB-7500

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

Figure 1 - Parts of a Fiber Optic Connector

Return loss measurement of fiber optic components

Sources of End Face Contamination on Fiber Optical Interconnects and Recommended Best Practices for Removing the Contaminates

FastReporter 2 DATA POST-PROCESSING SOFTWARE

ENCIRCLED FLUX (EF) TEST SOLUTIONS SPSB-EF LAUNCH MODE CONDITIONER AND FLS-600-NS1548 LIGHT SOURCE DESIGNED FOR CONTROLLED MULTIMODE LOSS TESTING

2.5mm CLEANCLICKER 750 Fiber Optic Cleaner Performance Verification Report OptiTap-Style Connectors

White Paper: Standard-Compliant Certification & Best Practices Ensure Fiber End-face Cleanliness to Eliminate the #1 Cause of Fiber Failure

Mariner Microspray and Low-Flow Electrospray Fused Silica Spray Tip and Capillary Kit. Operating Instructions. 1 Product Description.

UNSIGNED HARDCOPY NOT CONTROLLED

Agilent 81662A and 81663A DFB Laser Source Modules User s Guide

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

ENCIRCLED FLUX (EF) TEST SOLUTIONS

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507

Connections You Can Count On.

USERS MANUAL EasySplicer

Cleaning a Fibre Optic Solution

Certified Fibre Optic Specialist - Testing

Requests for Daily Care and Maintenance

Fiber Optic Connector Cleaning Solutions

Requests for Daily Care and Maintenance

SILENT KNIGHT. IntelliKnight Smoke Detector Cleaning and Testing Instruction. Equipment Needed. Testing Equipment. Cleaning Equipment

3M Benchtop Air Ionizer 963E. User s Guide

Multi fiber connector: Visual inspection and cleaning guide

FIBER OPTIC CONNECTOR CLEANERS

A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

The GAK-800 Heated Exercise Gas Analyzer Accessory Kit

Agilent 81662A and Agilent 81663A DFB Laser Source Modules. User s Guide

Notes for Users. Quick Installation Guide 2. Unpacking

OPERATION MANUAL. LED Coupling OM-TR355E. Please read this operation manual carefully and file for future reference.

Event dead zone: 0.8 m. Attenuation dead zone: 4 m. Dynamic range: up to 50 db. Platform compatibility. FTB-200 Compact Platform

Connecting At The Speed Of Light

INSTALLATION & OPERATING INSTRUCTIONS

AXS-100. Series NETWORK TESTING OPTICAL HANDHELD OTDR. Compact, rugged, lightweight OTDRs optimized for access/fttx and LAN/WAN network testing

Instructions for Use: Fiberscope and LED Light Source

Precision Infrared Thermometer. Users Manual

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

AXS-100 Series HANDHELD OTDR. Telecom Test and Measurement

SYSTIMAX 360 Low-Profile, Stackable Splice Tray Kit Instructions

Tank, Heater, and Control Operation Manual REV. E DATE: 04May2015

Routine Cleaning of the icolor 700 Continuous Digital Label Press

Requests for Care and Maintenance

fi-4340c CONSUMABLE REPLACEMENT

INDUSTRY STATS SNAPSHOT

Fiber Optic Cleaning Overview. Prepared by Steve Lytle, Westover Scientific March 10 th, 2004

USERS MANUAL EasySplicer

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

FTB-700 Series. OTDR for FTB-1. User Guide

Hydraulic Crimping Heads and

Basic Professional Fiber Optic Installation

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

User Guide. T-25S-L (Coating Clamp) T-25U-L (Coating Clamp)

Hydraulic Crimping Systems

568X, 587X, 588X Series

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

Contents. Introduction... A Note About Heatsinks... Precautions...

STAINLESS STEEL UNITS

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

Introduction. Disclaimer. Application. EasySplicer components

4-Channel Contact Closure Fiber Link Card System

100B MINI-OTDR FTB-100B. EXFO s rugged, flexible OTDR-dedicated portable platform. Telecommunications Test and Measurement

Compression Port Adapter Kit for VS Series Leak Detectors

HIGH POWER FIBER OPTIC PATCHCORDS

3M Crimplok + Connector 8700-UPC & APC SM SC 900 µm

Dräger Bump Test Station Calibration and Bump Testing

OTDR. Optical Time Domain Reflectometer. User Guide

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION

FX-PDD Duct Smoke Detector Installation Sheet

Models TX-KE and TX-KP Toxic Gas Transmitters

Thermal Stripper, TSAB-40 User Manual

The FTA-02 Fiber Arranger

Leak-Seeker I Refrigerant Leak Detector

Intelligent Optical Link Mapper (iolm)

Guide for Thin Film Evaporation Edited 7/22/13 by Stephen Albright, BJAM & Steven Palefsky

DYNA-CRIMP* Hydraulic Crimping Head, PN 69099

Fiber Optic Products Catalog


CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

Transcription:

Connector Maintenance Jean-François Lavoie, Product Manager, Industrial and Scientific Division Connectors are designed to require minimum maintenance in order to provide reliable operation for many years. To ensure accurate readings and minimum insertion loss, it is important that fiber ends and optical ports be clean at all times. Proper cleaning also prevents the buildup of dirt, dust and other foreign substances especially in connector pins. This paper is designed to address the proper maintenance of To properly carry out connector maintenance, you must be familiar with the visual inspection procedure. It is imperative that there be no dirt on the connector core. Any connector that has a scratch across the core, or a scratch that appears to end in the core, must be rejected. Any connector with more than one scratch or an obvious scratch must also be eliminated. In addition, any patchcord showing obvious signs of wear on the ferrule, cladding or core must be rejected (see Figures 1 and 2). FC, SC, ST and E-2000 connectors Singlemode and multimode fibers Bulkhead connectors, FOAs, detector ports and EUI connectors Before you start the cleaning procedure you will need the following standard cleaning equipment: Isopropyl alcohol 1 Soft tissues (Kimwipes ) Cotton swabs (cleaning tips) Compressed air 2 FOMS-400X-UNIV (to check for cleanliness and scratches) Figure 1. Scratched connectors must be rejected The following cleaning instructions contain some general safety precautions, which must be observed during all cleaning phases. 1 Use isopropyl alcohol that is 98 % pure or more. When using isopropyl alcohol to clean an optical device, do not proceed immediately to dry the surface with compressed air (except when you are cleaning very sensitive optical devices). This is because the dust and dirt are in solution and will leave behind a filmy deposit once the alcohol has evaporated. Therefore, you should first remove alcohol and dust with a soft tissue, and then use compressed air to blow away any remaining particles. Figure 2. Worn connectors must be rejected 2 It is essential that compressed air be free of dust, water and oil. Use only clean, dry air. Otherwise, this could lead to filmy deposits or scratches on the surface of the connector. This will result in reduced performance of your transmission system.

Cleaning the Connectors Below are a few hints on how to keep your connectors in the best possible condition. When inserting a connector ferrule into a connector or adapter, ensure that the ferrule tip does not touch the outside of the mating connector or adapter. Otherwise, the fiber end will rub against an unsuitable surface, producing scratches and dirt deposits on the fiber. Please note that the ceramic or metal sleeves inside the adapter are tightly fitted. Carefully rotate the ferrule in the adapter in order to align it with the connector key. Do not force the ferrule into the adapter. Every time there is a disconnection or an undesirable contact, you must carry out the cleaning procedure. This ensures reliable patchcords, and consequently, accurate readings. Still, this procedure does not replace careful handling of patchcords. The use of protective caps is also necessary, but does not guarantee the cleanliness or the quality of a patchcord. This procedure conforms to the GR-326 standard, entitled Singlemode Optical Connectors and Jumper Assemblies. Cleaning the Fiber Ends 1. Make sure the fiber is not active. 2. Remove the protective caps. 3. Gently wipe the fiber end with a lint-free Kimwipe moistened with isopropyl alcohol (see Figure 3). 4. To dry, use a lint-free, dry Kimwipe first, and then use compressed air. 5. Verify the cleanliness of the connector with your FOMS-400X-UNIV (see Figure 4). The patchcord is clean when there is no debris touching the cladding or the core. Figure 3. Cleaning fiber ends Cleaning connectors is difficult because the core diameter of a singlemode fiber measures only about 9 µm. This generally means you will not be able to see scratches on the surface. In order to be certain of the connection s surface condition and to be able to check it after cleaning, you need a fiber-optic microscope such as the FOMS-400X-UNIV. Warning: Never look into the end of an optical cable that is connected to an active source! Figure 4. Verify connectors with your FOMS-400X-UNIV

Cleaning the Bulkhead Connector 1. Remove the protective caps. 2. Slowly insert a cleaning tip that has been dipped in isopropyl alcohol into the bulkhead connector (see Figures 5 and 6). A gentle rotating movement may help. 3. To dry, insert a dry cleaning tip. 4. Blow away any remaining lint with clean compressed air. Cleaning the Fiber-Optic Adapter (FOA) 1. Remove the FOA from the instrument. 2. Slowly insert a cleaning tip that has been dipped in isopropyl alcohol into the FOA (see Figure 7). A gentle rotating movement may help. 3. To dry, insert a dry cleaning tip. 4. Blow away any remaining lint with clean compressed air (see Figure 8). Figure 5. Cleaning setup Figure 7. Cleaning the FOA Figure 6. Cleaning bulkhead connectors Figure 8. Use compressed air to end the procedure

Cleaning the Detector Ports To ensure the maximum accuracy of power measurements, power meter detectors must be kept clean at all times. When not in use, the detector(s) should be covered with a protective cap. In addition, the optical source port and fiber end should be cleaned occasionally to minimize insertion loss. The cleaning tips supplied with EXFO test equipment are specially designed to clean the detector port(s) without having to disassemble the unit. To clean the detector port(s), 1. Remove the protective cap from the detector. 2. If the detector is dusty, blow dry using compressed air. 3. Carefully remove a cleaning tip from the package, without touching the cotton swab. 4. Moisten the cleaning tip with isopropyl alcohol. 5. Slowly insert the cleaning tip into the port until it reaches the detector s protective window (gently rotating the cleaning tip clockwise may help). 6. While applying moderate pressure, turn the cleaning tip one full turn. Be careful not to damage the detector window (see Figure 9a). 7. Gently withdraw the cleaning tip. 8. Using compressed air, blow the detector dry (see figure 9b) or repeat steps 5 to 7 with a dry cleaning tip. Figure 9a. Cleaning the detector port(s) Figure 9b. Cleaning the detector port(s) To help keep the source port clean, EXFO recommends placing a protective cap on it whenever it is not in use. Also, always clean fiber ends before connecting them to the power meter port.

Cleaning the EUI Connector 1. Remove the EUI from the instrument (see Figure 10). 2. Slowly insert a cleaning tip that has been dipped in isopropyl alcohol into the EUI connector (see Figure 11). A gentle rotating movement may help. 3. To dry, insert a dry cleaning tip first, then use clean compressed air (see Figure 12). 4. Clean the ferrule in the connector port using a lint-free Kimwipe moistened with isopropyl alcohol (see Figure 13). 5. Dry thoroughly with a dry lint-free Kimwipe. 6. Put the EUI connector back onto the instrument (see Figure 14). Figure 12. Drying the EUI with compressed air Figure 10. Removing the EUI Figure 13. Cleaning the ferrule in the connector port Figure 11. Cleaning the EUI Figure 14. Putting the EUI connector back onto the instrument

CORPORATE HEADQUARTERS 465 Godin Avenue Vanier (Quebec) G1M 3G7 CANADA Tel.: 1 418 683-0211 Fax: 1 418 683-2170 EXFO AMERICA 1201 Richardson Drive, Suite 260 Richardson TX 75080 USA Tel.: 1 800 663-3936 Fax: 1 972 907-2297 EXFO EUROPE Le Dynasteur 10/12, rue Andras Beck 92366 Meudon la Forêt Cedex FRANCE Tel.: +33.1.40.83.85.85 Fax: +33.1.40.83.04.42 EXFO ASIA-PACIFIC 151 Chin Swee Road, #03-29, Manhattan House SINGAPORE 169876 Tel.: +65 333 8241 Fax: +65 333 8242 TOLL-FREE (USA and Canada) Tel.: 1 800 663-3936 info@exfo.com ANOTE058.2an