Product ortfolio Integrated climate control
Portfolio Outdoor unit range Capacity (HP) System Product name 4 5 6 8 0 4 6 8 0 RYYQ-T Heat pump with continuous heating () () () RXYQ-T Heat pump without continuous heating () () () AIR COOLED HEAT pump RXYSQ-P8V (Single phase) RXYSQ-P8Y (Three phase) RTSYQ-PA Heat pump optimised for heating RXYCQ-A for standard cooling & heating requirements REYQ-P8/P9 Small footprint combination HEAT RECOVERY REYHQ-P High COP combination REYAQ-P for connection with heating only hydrobo WATER COOLED STANDARD SERIES GEO- THERMAL SERIES H/R - H/P H/R - H/P RWEYQ-P RWEYQ-PR System Product name 4 5 8 0 4 6 8 0 Capacity class 40 80 60 460 500 540 66 AIR COOLED REPLACEMENT VRV HEAT RECOVERY - HEAT PUMP RQYQ-P VRVIII-Q - H/P RQCEQ-P VRVIII-Q - H/R Single unit Multi combination Not a standard combination (free combination)
: component is connectable : component is not connectable Not all components are connectable at the same time to one outdoor unit. Refer to the engineering databook for more information. 4 6 8 0 4 6 8 40 4 44 46 48 50 5 54 Indoor units Ventilation Air curtain Hydrobo connection Control systems 4 6 8 0 4 6 8 40 4 44 46 48 50 5 54 7 744 86 848 Capacity (HP) VRV type indoor units (such as FXSQ) Residential type indoor units (such as Daikin Emura) Heat Reclaim ventilation (such as VAM) Fresh air indoor units (such as FXMQ-MF) AHU connection kit (such as EKEXV) Biddle Air curtain for VRV (CYV) Low temperature hydrobo for VRV High temperature hydrobo for VRV Individual control (such as BRC) Centralised control (such as DCS*/DST) Network solutions (such as DCS6*/DAM/DMS)
Indoor unit range VRV air conditioning brings summer freshness and winter warmth to offices, hotels, department stores and many other commercial premises. It enhances the indoor environment and creates a basis for increased business prosperity and whatever the air conditioning requirement, a Daikin indoor unit will provide the answer. VRV air conditioning can be supplied via 6 different indoor unit models in a total of 6 variations. VRV indoor units CEILING MOUNTED CASSETTE Model Round flow cassette Auto cleaning function Presence & floor sensor Fully flat cassette Presence & floor sensor -way blow ceiling mounted cassette Ceiling mounted corner cassette Product name FXFQ-A FXZQ-A FXCQ-A FXKQ-MA Capacity 5 0 5 40 50 6 7 80 00 5 40 00 50 Small concealed ceiling unit FXDQ-M9 CONCEALED CEILING Slim concealed ceiling unit Concealed ceiling unit with inverter driven fan Concealed ceiling unit with inverter driven fan FXDQ-A FXSQ-P FXMQ-P7 Large concealed ceiling unit FXMQ-MA 4 WALL MOUNTED Wall mounted unit FXAQ-P CEILING SUSPENDED Ceiling suspended unit 4-way blow ceiling suspended unit FXHQ-A FXUQ-MA FLOOR STANDING Floor standing unit Concealed floor standing unit FXLQ-P FXNQ-P Cooling capacity (kw).7..8.6 4.5 5.6 7. 8.0 9.0. 4.0 6.0.4 8.0 Heating capacity (kw).9.5. 4.0 5.0 6. 8.0 9.0 0.0.5 6.0 8.0 5.0.5 Nominal cooling capacities are based on: indoor temperature: 7 CDB, 9 CWB, outdoor temperature: 5 CDB, equivalent refrigerant piping: 5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 0 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent refrigerant piping: 5m, level difference: 0m Optional 4 Not connectable to VRV III-S 4
Stylish indoor units CEILING MOUNTED CASSETTE Model Product name Capacity Connectable outdoor unit 5 0 5 5 4 50 60 7 RYYQ-T RXYSQ-P8V RXYSQ-P8Y Round flow cassette Auto cleaning function FCQG-F Presence & floor sensor Fully flat cassette FFQ-C Presence & floor sensor CONCEALED CEILING WALL MOUNTED Small concealed ceiling unit FDBQ-B Slim concealed ceiling unit FDXS-F Concealed ceiling unit with inverter driven fan Daikin Emura Wall mounted unit Wall mounted unit FBQ-C FTXG-JA/ JW CTXS-K FTXS-K Wall mounted unit FTXS-G CEILING SUSPENDED Ceiling suspended unit FHQ-C Neura floor standing unit FVXG-K FLOOR STANDING Floor standing unit FVXS-F Flei type unit FLXS-B Optional 5 class unit not available for RYYQ-T 5
Ventilation range Ventilation: provision of fresh air Pre conditioning: cooling or heating of incoming fresh air to maintain a consistent temperature for maimum comfort Humidification: optimise the balance between indoor and outdoor humidity Product name Components of indoor air quality Air flow rate (m /h) 0 00 400 600 800,000,500,000 4,000 6,000 8,000 VAM-FA/FB Ventilation HEAT RECLAIM VENTILATION VKM-G Ventilation Pre conditioning VKM-GM Ventilation Humidification Pre conditioning OUTDOOR AIR PROCESSING UNIT FXMQ-MF Ventilation Pre conditioning VRV AIR HANDLING APPLICATIONS EKEXV-kit Ventilation Pre conditioning Not connectable to VRVIII-S (RXYSQ-P8V, RXYSQ-P8Y) Air flow rate is a calculated indication only, based on the following values: heating capacity EKEXV-kit * 00m³/h For more information on Daikin air handling units refer to your local dealer 6
Biddle air curtain range BIDDLE AIR CURTAIN FREE HANGING Product Name CYV S/M/L-DK-F BIDDLE AIR CURTAIN CASSETTE CYV S/M/L-DK-C BIDDLE AIR CURTAIN RECESSED CYV S/M/L-DK-R 4 Door height (m) Biddle air curtain range for VRV.m.0m.75m.5m.4m.m.5m.0m.5m S M L S M L S M L Favourable e: covered shopping mall or revolving door entrance Normal e: little direct wind, no opposite open doors, building with ground floor only Unfavourable e: location at a corner or square, multiple floors and / or open stairwell Installation condition Hydrobo range Capacity Product name Leaving water temperature range 80 5 low temperature hydrobo HXY-A 5 C - 45 C high temperature hydrobo HXHD-A 5 C - 80 C Only connectable to REYAQ-P Network solutions Screen Control Monitoring Options Other Layout screen Touch screen Basic control functions:on/off, temp, setting, air flow settings Refrigerant containment check Temperature limitation Setback Automatic changeover Weekly schedule & special day pattern Timer etension Forced off Basic control functions: ON/OFF status, operation mode, set point temp. Filter status Malfunction code History (operation, malfunction ) Visualisation PPD Web access & control HTTP option Interlock Pre-cool/heat Sliding temperature Free cooling ACNSS connection Air Conditionning Network Service System Maimum indoor unit groups ITC 64 ITM + + + + Std + 560 DMS-IF 64 BACNET 464 Interface for Lonworks networks Interface for BACnet networks 7
GREAT NEWS VRV IV SETS THE STANDARD AGAIN find the latest information on www.daikineurope.com/vrv-iv Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No epress or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. eplicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. FSC ECPEN-0A VRV products are not within the scope of the Eurovent certification programme. Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 00, B-8400 Oostende - Belgium - www.daikin.eu - BE 04 0 6 - RPR Oostende ECPEN-0A XXX 0/ Copyright Daikin The present publication supersedes ECPEN-0. Printed on non-chlorinated paper. Prepared by La Movida, Belgium Resp. Ed.: Daikin Europe N.V., Zandvoordestraat 00, B-8400 Oostende