Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Similar documents
QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Duct Temperature Sensors

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

for relative humidity and temperature

for relative humidity and temperature with calibration certificates

for relative humidity and temperature

Room Temperature Sensors

Duct Air Quality Sensors

Room Air Quality Sensors

QPM21 Series Duct CO 2 and Air Quality Sensors

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Room air quality sensors

Duct Temperature Sensors

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Differential pressure sensors

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

Room Temperature Controller

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

PRELIMINARY EDITION

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Immersion Temperature Controller

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Frost Protection Thermostat

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Hygro/hygrothermal transducers (hygrometric)

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

Room Temperature Controller

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Semi flush-mount room thermostat

Room Temperature Controller with LCD

BC3250. Blowdown Controller

No. Icon Name Function

LC1350 Level Controller

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Self-learning Room Temperature Controller

Flame Safeguards LFE10. Building Technologies HVAC Products

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

MANDÍK MEASUREMENT AND CONTROL SYSTEM

Hygro/hygrothermal transducers (hygrometric)

Room Temperature Sensor

Infrared Flame Detectors

Preliminary Release. Room Temperature

UV Flame Supervision System

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Flame Safeguards LFE10. Building Technologies HVAC Products

HYGROPHIL H process hygrometer

THERMASREG TR 040 THERMASREG TR 060

Heating Controller. Building Technologies HVAC Products. Synco 700

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

Heating Element. Building Technologies HVAC Products

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

Room Temperature Sensors

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Room thermostats with LCD for wall mounting

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

DMFPM-2R MULTIFUNCTIONAL

Room thermostat with Auto Timer, Option External Input

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

The fan is switched to the selected speed via control output Q1, Q2 or Q3.

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Self-learning Room Temperature Controller

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

02/11/2015

Self-learning Room Temperature Controller

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Sensor unit MC2 with analog output for Freon gases and refrigerants

RVL479. Heating Controller. for use with a partner unit

Flush-mount room sensor KNX S-Mode / KNX LTE- Mode / KNX PL-Link

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Room Temperature Controllers

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

LAE10 LFE10. Use. Series 02

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Burner Management System

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

PM100V PM80V PM15V. Ex works. Depending on the specific range of application a regular ecalibration of the sensor head (PMU-V) has to be effected.

Wall-mounted room thermostat with LCD

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

MELA Sensortechnik GmbH

Relative Humidity Transmitters

Self-learning Room Temperature Controller

LC2200 Level Controller Installation and Maintenance Instructions

Transcription:

1 882 1882P01 Symaro Duct Sensors for relative humitidy (high accuracy) and temperature QFM31 Use Examples Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 4 20 ma for relative humidity and temperature Very high measuring accuracy across the entire measuring range Capacitive humidity measurement Range of use 40 +70 C / 0 100 % r h The QFM31 is for use in ventilation and air conditioning plants where high accuracy and short response times for measuring relative humidity are required The measuring range covers the entire humidity range of 0 100 % Storage and production facilities in the paper, textile, pharmaceutical, food, chemical and electronics industry, etc Laboratories Hospitals Computer and EDP centers Indoor swimming pools Greenhouses The QFM31 is used as a control sensors in the supply or extract air limit sensor for maximum limitation of supply air humidity after a steam humidifier limit sensor, eg for measured value indication or for connection to a building automation and control system sensor for enthalpy and absolute humidity, together with the AQF611 (refer to Data Sheet N1899) or SEZ220 (refer to Data Sheet N5146) CE1N1882en 06062005 Siemens Building Technologies HVAC Products

Type summary Type reference measuring range signal output measuring range signal output Operating voltage QFM3100 None None 0100 % Aktive, DC 010 V AC 24 V or DC 135 3 QFM3101 None None 0100 % Aktive, 4 20 ma DC 135 3 QFM3160 050 C / 0 70 C / 35+ 35 C QFM3171 050 C / 0 70 C / 35+ 35 C Aktive, DC 010 V 0100 % Aktive, DC 010 V AC 24 V or DC 135 3 Aktive, 4 20 ma 0100 % Aktive, 4 20 ma DC 135 3 Ordering When ordering, please give name and type reference, eg: Duct sensor QFM3160 Equipment combinations The QFM31 is for use with all types of systems and devices that can acquire and handle the sensor s DC 010 V or 4 20 ma output signal Technical design Relative humidity The sensor acquires relative humidity via its capacitive sensing element whose capacitance varies as a function of the relative humidity of the ambient air An electronic circuit converts the sensor s signal to a continuous DC 010 V or 4 20 ma signal, corresponding to a relative humidity of 0100 % The sensor acquires the temperature via its sensing element whose electrical resistance varies according to the temperature of the ambient air This variation is converted to an active DC 010 V or 4 20 ma output signal, corresponding to a temperature range of 050 C, 35+35 C, or 070 C The measuring range can be selected Burden diagram Output signal, terminal I1 / I2 900 800 1882D02en Burden [Ohm] 700 600 500 400 300 Inadmissible range! Admissible range 200 100 0 0 10 20 30 40 Operating voltage [DC V] 2/6 HVAC Products 06062005

Mechanical design The duct sensor consists of housing, printed circuit board, connection terminals, mounting flange and immersion rod with measuring probe The 2-sectional housing is comprised of base and removable cover (screwed) The measuring circuit and the setting element are located on the printed circuit board inside the cover, the connection terminals on the base The sensing elements are located at the end of the measuring probe and protected by the filter cap Cable entry is made via the cable entry gland M16 (IP 54) supplied with the sensor, which can be screwed into the housing Immersion rod and housing are made of plastic and rigidly connected The sensor is fitted with the mounting flange supplied with the sensor The flange is to be placed over the immersion rod and then secured in accordance with the required immersion length Setting element Range 1 2 3 Measuring range 123 Test function active U1 U2 I1 I2 10 V 20 ma 10 V 20 ma 0 V 0 V 4 ma 4 ma 1882Z01en The setting element is located inside the cover It consists of 6 pins and a shorting plug It is used for selecting the required temperature measuring range and for activating the test function The different shorting plug positions have the following meaning: For the active temperature measuring range: Shorting plug in the left position (R1) = 35+35 C, Shorting plug in the mid position (R2) = 050 C (factory setting) Shorting plug in the right position (R3) = 070 C For the active test function: Shorting plug in the horizontal position: The values available at the signal output are those given in the table Test function active Behavior in the event of fault If the temperature sensor is faulty, the voltage at signal output U2 (I2) is 0 V (4 ma) after 60 seconds, the humidity signal at signal output U1 (I1) increases to 10 V (20 ma) If the humidity sensor is faulty, the voltage at signal output U1 (I1) is 10 V (20 ma) after 60 seconds; the temperature signal remains active Accessories Name Filter cap (for replacement) Type reference AQF3101 HVAC Products 06062005 3/6

Engineering notes Cable routing and cable selection To power the sensor, a transformer for safety extra low-voltage (SELV) with separate windings for 100 % duty is required When sizing and protecting the transformer, the local safety regulations must be observed When sizing the transformer, the power consumption of the duct sensor must be taken into consideration For correct wiring of the sensor, refer to the Data Sheets of the devices with which the sensor is used The permissible line lengths must be observed When laying the cables, it must be observed that the longer the cables run side by side and the smaller the distance between them, the greater the electrical interference Shielded cables must be used in environments with EMC problems Twisted pair cables are required for the secondary supply lines and the signal lines Note to QFM2171 Terminals G1(+) and I1( ) for the humidity output must always be connected to power, even if only the temperature output G2(+) and I2( ) is used! Mounting notes Location Caution! Fitting instructions The sensor should be mounted in the middle of the duct wall If used in connection with steam humidifiers, the minimum distance after the humidifier should be 3 m, the maximum distance 10 m If the application involves dew point shifting, the sensor must be fitted in the extract air duct Only the flange must be fitted to the duct wall The sensor is then inserted through the flange and engaged The seal between housing and cover must not be removed, or else degree of protection IP 65 will be no longer ensured The measuring rod's sensing elements are sensitive to impact Avoid any such impact on mounting Fitting instructions are printed on the sensor s packing Commissioning notes Check wiring before switching on power The temperature measuring range must be selected on the sensor, if required 4/6 HVAC Products 06062005

Technical data Power supply Cable lengths for the measuring signal Functional data sensor" Functional data " sensor" Degree of protection Electrical connections Environmental conditions Materials and color Standards Weight Operating voltage Frequency Power consumption AC 24 V ± 20 % or DC 1353 50 / 60 Hz at AC 24 V 1 VA Max perm cable lengths refer to Data Sheet of the device handling the signal Measuring range 0100 % rh Measuring accuracy at 23 C 0100 % rh ± 2 % dependency Time constant 005 % rh/ C approx 20 s in moving air Output signal, linear (terminal U1) DC 010 V 0100 % rh max ± 1 ma Output signal, linear (terminal I1) Burden Measuring range 4 20 ma 0100 % rh refer to "Function" 050 C (R2 = factory setting), 35+ 35 C (R1), 070 C (R3) Sensing element Pt 1000 class B to DIN EN 60 751 Measuring accuracy at 1535 C 35+70 C Time constant Output signal, linear (terminal U2) Output signal, linear (terminal I2) Burden ± 06 K ± 08 K approx 20 s in moving air DC 010 V 050 C / 35+ 35 C / 070 C max ± 1 ma 420 ma 050 / 35+ 35 / 070 C refer to "Function" Housing IP 65 to IEC 529 Safety class III to EN 60 730 Screw terminals 1 25 mm 2 or 2 15 mm 2 Cable entry gland (enclosed) M 16 x 15 Operation to Climatic conditions (housing with electronics) Mechanical conditions Transport to Climatic condition Mechanical conditions Base Cover Immersion rod Filter cap Mounting flange Cable entry gland Sensor (complete assembly) Packaging IEC 721-3-3 class 4K2 40+ 70 C 0100 % r h (with condensation) class 3M2 IEC 721-3-2 class 2K3 25+ 70 C < 95 % r h class 2M2 polycarbonate, RAL 7001 (silver-grey) polycarbonate, RAL 7035 (light-grey) polycarbonate, RAL 7001 (silver-grey) polycarbonate, RAL 7001 (silver-grey) PA66 GF35 (black) PA, RAL 7035 (light-grey) silicon-free corrugated cardboard Product safety Automatic electrical controls for household and similar use EN 60 730-1 Electromagnetic compatibility Immunity Emissions conformity to conformity to Australian EMC framework Radio Interference Emission Standard conformity UL 873 Incl packaging EN 61 000-6-1 EN 61 000-6-3 EMC directive 89/336/EEC Radio Communication Act 1992 AS / NZS 3548 0208 kg 5/6 HVAC Products 06062005

Connection terminals QFM3100 QFM3101 QFM3160 QFM3171 G G0 (rh) U1 1882G03 G1 (rh) I1 1882G04 G (R1 = 35+35 C / R2 = 050 C / (rh) R3 = 070 C) G0 U1 U2 1882G01 G1 (rh) I1 G2 (R1 = 35+35 C / R2 = 050 C / R3 = 070 C) I2 1882G02 G, G0 Operating voltage AC 24 V (SELV) or DC 1353 G1, G2 Operating voltage DC 1353 U1 Signal output DC 010 V for relative humidity 0100 % U2 Signal output DC 010 V for temperature range 050 C / 0 70 C / 35+ 35 C I1 Signal output 4 20 ma for relative humidity 0100 % I2 Signal output 4 20 ma for temperature range 050 C / 0 70 C / 35+ 35 C Note on connection terminals of the QFM3171: Terminals G1(+) and I1 ( ) for the humidity output must always be connected to power, even if only the temperature output G2 (+) and I2 ( ) is used! Dimensions 80 60 28 28 39 3 14,5 M16 x 1,5 274 ø 20 80 50 235 ø 15 (41) min 90, max 206 1882M01 (62,8) 21(16) 60 Drilling template with (without) mounting flange Dimensions in mm 6/6 2004 Siemens Switzerland Ltd Subject to change HVAC Products 06062005