WELCOME TO REMEHA, THE EXPERT CHOICE REMEHA QUINTA RANGE FEATURES AND BENEFITS

Similar documents
WELCOME TO REMEHA, THE EXPERT CHOICE REMEHA QUINTA RANGE FEATURES AND BENEFITS

The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 310/610 ECO PRO RANGE FEATURES AND BENEFITS

GAS 610 ECO PRO. The new Remeha. Condensing Boiler Range REMEHA GAS 310/610 ECO PRO

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Remeha Quinta 45 and 65

Remeha Quinta 30. Technical information. High-efficiency. condensing boiler for. wall mounted. installation. Output: kw

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

ENERGY TOP. Condensing boiler solutions

Suggested Schematics with Control and Power Wiring details

Remeha Quinta 115. Technical information. Remeha Quinta 115. High-efficiency. condensing boiler for wall. mounted installation.

CALORA TOWER GAS 15S EX CALORA TOWER GAS 25S EX CALORA TOWER GAS 35S EX

Remeha Quinta 85. Technical information. Remeha Quinta 85. High-efficiency. condensing boiler for wall. mounted installation.

Sirius WH. Working towards a cleaner future

Sirius FS. Working towards a cleaner future

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

24V dc Terminals X4. 230Vac Terminals X V dc Electrical connections Volt free Room thermostat on/off

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

1 VICTRIX ZEUS Superior kw I features

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

EMC-M 24 EMC-M 24/28 MI EMC-M 30/35 MI EMC-M 34/39 MI

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

WOLF GAS CONDENSING BOILERS COMFORTLINE

Compact HRE Boiler Range. The smart choice for heating and hot water

Power X High Power Condensing Wall-Hung Boilers

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

Compact HE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists

Seradens Super Seradens Super Plus

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

Power X High Power Condensing Wall-Hung Boilers

CAST IRON ATMOSPHERIC BOILERS

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

Ciao Green Condensing Wall-Hung Boilers

INDEPENDENT COMBINATION & SYSTEM BOILERS.

Baxi 600, 400 & 200 boilers. Range guide

VICTRIX Superior kw Export VICTRIX Superior kw X Export

C 330 ECO - C 630 ECO

The iqe Boiler Range. Combination and System T Boilers.

Remeha Avanta Plus. Remeha Avanta Plus. Installation and service manual. Remeha Avanta Plus 28c. Remeha Avanta Plus 35c. Remeha Avanta Plus 39c

Residential Heating Boilers

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Installation & Service Manual Remeha Avanta Range. 24c 28c 35c 39c 18s 24s 30s

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water

Remeha Gas 610 ECO. Technical information. Remeha Gas 610 ECO. High efficiency condensing. boiler with low NO X emission. Heat outputs: kw

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Ultra Boiler Series 1 & 2 Jacket Parts

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Project Name: Location: Engineer: Contractor: I. GENERAL

Our Boiler Family Our Boiler Family

S-AF Floor Standing Condensing Boiler kW

HEAT ONLY & COMBI BOILER

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

ecotec plus New high efficiency condensing combination and system boiler ranges

Introduction. Our boilers are among the most efficient available, designed to be easy to install, reliable and economical.

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

AC WhisperGen System Product Specification 11 June 2003

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

INSTALLATION AND SERVICING

Single Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054

Strebel SC-B Wall-Hung Condensing Boiler

Q - Series Boiler. Troubleshooting Manual

Ultramax PB. Floor standing premix gas fired condensing boilers with outputs at 65, 85, 100 & 120kW BOILERS

Installation and Servicing Instructions R29 & R40 HE conventional Wall mounted condensing boiler for central heating

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

Compact. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

PRODUCT CATALOGUE Issue 3 SYSTEM BOILERS COMBI BOILERS FLOOR STANDING BOILERS WATER HEATERS SPARE PARTS AFTER SALES SERVICE TRAINING

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

SEDBUK & HARP. the complete range of oil and gas fired condensing boilers. Warmflow Boilers HIGH EFFICIENCY

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

Wall hung combination

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

Hamworthy. Varmax. New. Fully modulating, low NOx, stainless steel, condensing boilers Natural Gas or LPG Outputs 120kW to 900kW

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

95% Hamworthy Fully Modulating, Low NOx, Stainless Steel, Condensing Modular Boilers. Wessex ModuMax mk3. New. Restyled with latest Siemens controls

Logic+ Combi

turbomax plus High performance combination boiler range

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

NEW BUILD YOUR COMPLETE SOLUTION.

High temperature air-to-water heat pumps

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Light commercial products. High output boilers Cascade systems

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

Alpha CD13R,18R and 24R

and Installation Instructions The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack.

SPECIFICATIONS - NIKE

Transcription:

QUINTA RANGE

WHAT S INSIDE 03 WELCOME TO REMEHA 03 REMEHA QUINTA RANGE 04 BOILER CONSTRUCTION 07 OPERATING PRINCIPLE 08 TECHNICAL INFORMATION 10 ENGINEERING SPECIFICATION 12 DIMENSIONS AND CONNECTIONS 14 TYPICAL INSTALLATION 25 ELECTRICAL INSTALLATION AND CONTROLS 26 BOILER CONTROLS 29 QUINTA ACE 160 SPECIFICATIONS 31 FLUE OPTIONS 41 PLUME KITS 54 QUINTA FLUECADE SYSTEM 56 FLUECADE KITS 62 FLUECADE COMPONENTS 67 CASCADE OPTIONS 68 INSTALLATION AND CONFIGURATION 75 TECHNICAL SUPPORT 75 DECLARATION OF COMPLIANCE

QUINTA RANGE 03 WELCOME TO REMEHA, THE EXPERT CHOICE WE LEAD THE WAY IN INNOVATION, RELIABILITY AND EFFICIENCY FOR ADVANCED COMMERCIAL HEATING SOLUTIONS. We re completely focused on commercial heating solutions and are at the forefront of condensing gas boiler technology we don t manufacture boilers for anyone else. We invest heavily in research and development which enables our specialist teams to design high performance products at every level. From using the latest materials and manufacturing All our boilers share the same simple design so they re expandable, adaptable and future-proofed. blueprint sign-off through to supply and installation, our customer service and product support is our number one priority. REMEHA QUINTA RANGE The Quinta Range is a market-leading series of versatile, wall-hung condensing boilers designed for space heating and indirect hot water production. The Quinta Range includes the Quinta Pro, which is available in 30, 45, 55, 65, 90, 115 models and the Quinta Ace 160. With their extremely compact design, the Quinta Range can be installed individually or as part of a multi-boiler cascade or rig The Quinta Range is suitable for use on sealed systems and open-vented installations. x 2 FEATURES AND BENEFITS Higher than average energy savings Easy to install in smaller spaces; highly suitable for cascade operation Low pollutant emissions that meet environmental regulations including Building Research Establishment Environmental Assessment Method (BREEAM) regulation and Clean Air Act Clean, trouble-free operation Improved ease of maintenance easy installation Effective space saving solution Improved comfort energy-saving heating

QUINTA PRO BOILER CONSTRUCTION 1 2 3 4 5 6 13 12 14 7 15 8 11 9 10 KEY 1 Flue gas outlet/air intake 6 11 2 7 Combined Venturi and gas valve unit 12 Fan 3 8 Air intake silencer 13 4 Outlet for measuring combustion gases 9 14 Interior light 5 Ignition/ionisation electrode 10 Siphon 15 Non-return valve

BOILER CONSTRUCTION 05 QUINTA ACE BOILER CONSTRUCTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 24 23 22 21 20 19 18 17 16 15 KEY 1 Flue gas outlet/air intake 9 17 Gas pressure measuring point 2 10 Water pressure sensor 18 CU-GH control unit 3 Interior light 11 Return sensor 19 Gas valve unit 4 Flow sensor 12 20 Venturi 5 Adapter 13 Control panel 21 Fan 6 14 On/off switch 22 Non-return valve 7 15 Condensate collector 23 Automatic air vent 8 Ignition transformer 16 Air inlet silencer 24 Flue gas measuring point

OPERATING PRINCIPLE 07 QUINTA RANGE OPERATING PRINCIPLE approximately 5 C above the temperature of the system return water, then discharged vertically via the condensate collector, through the 80/125mm (Quinta Pro 30/45) or 100/150mm point (55ºC), this water vapour will begin to condense out in the boiler, transferring its latent heat into the system water, increasing the output of the boiler without increasing gas consumption. Combustion air is drawn into the closed air box by a variable speed fan, through the air inlet connection from the plant room (open- On the inlet side of the fan is a specially designed Venturi which is connected to the outlet side of the gas combi-block. sensor and other external/internal control inputs), the electronic control unit directly monitors the volume of gas and air being delivered to the premix burner. This mixture is initially ignited by the combined ignition/ionisation probe which then monitors the within the pre-set safety time cycle, the controls will shut the

QUINTA TECHNICAL INFORMATION 8.0-29.8 8.0-40.8 11.1-55.3 12.0-61.5 14.1-84.2 20.5-107.0 31.5-152.9 8.9-31.4 8.9-43.0 12.3-58.6 13.3-65.0 15.8-89.5 22.7-114.0 34.6-161.5 8.2-30 8.2-41.2 11.3-56.5 12.2-62 14.6-86 19.6-110.2 32-156 97.6% 97.6% 96.03% 97.6% 95.7% 95.4% 95.9% 99.4% 99.1% 97.8% 99.2% 97.9% 97.1% 98.0% 110.4% 110.6% 108.7% 110.4% 108.1% 108% 107.9% 89.5% 89.3% 88.1% 89.4% 88.2% 87.5% 88.3% 99.5% 99.6% 97.9% 99.5% 97.4% 97.3% 97.2% 94% 95% 93% 94% N/a N/a N/a A A A A N/a N/a N/a 91 124 171 187 N/a N/a N/a Natural gas Natural gas Natural gas Natural gas Natural gas Natural gas Natural gas 0.9-3.2 0.9-4.4 1.2-6.0 1.3-6.6 1.5-9.1 2.0-11.7 3.4-16.5 0.4-1.2 0.4-1.7 0.5-2.3 0.5-2.5 0.9-3.5 0.9-4.5 1.4-6.3 17-25 17-25 17-25 17-25 17-25 17-25 17-25 37-50 37-50 37-50 37-50 37-50 37-50 37-50 ¾ Male thread (22mm) ¾ Male thread (22mm) ¾ Male thread (22mm) ¾ Male thread (22mm) ¾ Male thread (22mm) ¾ Male thread (22mm) 1 Male thread (28mm) 80 80 100 100 100 100 100 125 125 150 150 150 150 150 14-50 14-69 19-93 21-104 28-138 36-178 30-65 30-67 30-68 30-68 30-68 30-72 30-62.3 70 150 120 100 160 220 200

TECHNICAL INFORMATION 09 QUINTA TECHNICAL INFORMATION 4.3 4.3 6.4 6.4 9.4 9.4 17.0 231 298 430 430 463 826 510 70 90 130 130 140 250 170 0.65 0.89 1.2 1.34 1.83 2.33 2.4 0.36 0.49 0.66 0.74 1.01 1.28 1.82 0.4 0.4 0.4 0.4 0.4 0.4 1.31 32mm 32mm 32mm 32mm 32mm 32mm 32mm 1¼ Male thread (32mm) 1¼ Male thread (32mm) 1¼ Male thread (32mm) 1¼ Male thread (32mm) 1¼ Male thread (32mm) 1¼ Male thread (32mm) 1¼ Male thread (32mm) 20-90 20-90 20-90 20-90 20-90 20-90 20-90 90 90 90 90 90 90 90 110 110 110 110 110 110 110 4 4 4 4 4 4 4 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.3 o/v 0.3 o/v 0.3 o/v 0.3 o/v 0.3 o/v 0.5 o/v N/a 53 53 60 60 67 68 147 49 49 56 56 65 65 123 x 2 37 37 32 32 29 35 35 38 45 45 45 52 51 55 46 53 53 53 60 59 63 0.101 0.101 0.110 0.110 0.123 0.123 0.191 1.8 1.8 1.8 1.8 1.8 1.8 2.2 18-39 18-68 23-80 23-88 20-125 45-199 47-275 0-10 0-10 0-10 0-10 0-10 0-10 0-10 6.3 6.3 6.3 6.3 6.3 6.3 6.3 X4D X4D X4D X4D X4D X4D X1B *Gas consumption based on lower heating value under standard heating conditions: T=288.15K, p=1013.25mbar. Gag 30.33, G25 29.25, G31 88.00 MJ/m 3. **Open vented option maximum operating temperature 75 C.

SUGGESTED ENGINEERING SPECIFICATION QUINTA PRO CONSTRUCTION The boiler will be a wall-hung type condensing boiler which may also be installed free-standing on a suitable frame. The single piece, cast aluminium heat exchanger and other major components are contained within a sealed air box. The boiler casing will be complete with a removable front section for maintenance purposes. Electrical and electronic controls will be contained within the instrument panel mounted in the drop-down lower front panel and also the electrical housing mounted on the inside right hand panel. HYDRAULIC, GAS AND FLUE CONNECTIONS condensate connections located at the bottom. The boiler will be be designed for central heating and indirect hot water production up to four bar. The boiler will be suitable for use on sealed systems and open-vented installations. OPERATION The boiler will be complete with a modulating control system that limits the maximum difference in temperature between the pre-mix burner (NG or LPG) with the gas/air ratio control system controlled internally. An intelligent, advanced boiler control will continuously monitor the boiler conditions, varying the heat output to suit the system load. The control will be able to react to and air/gas supply problems), maintaining boiler output for as a negative effect happen in the system, the boiler will reduce its output and/or shut down (shut-off mode), awaiting the negative conditions to return to normal before re-starting. The control frost protection will activate below 7 C with stage one activating CONTROLS The boiler will include a controls package that allows the actual and set values to be read and adjusted on the built-in digital display which also provides normal operating and fault code indication. The controls will come as standard with the following inputs/outputs: DHW temperature input High limit lock out Low water protection Outside sensor (optional) External shunt pump control External system pump control Fault alarm output DHW 3-port valve control or pump Open Therm connection. FEATURES Ultra-low NO x <37mg/kWh Fully modulating Quiet operation <52dB(A) LED illuminated interior Automatic maintenance warning PC connection ErP compliant Relay kit (optional) Premix burner and directives: 90/396EEC Gas appliances directive voltage directive 89/336/EEC E.M.C. directive ErP compliant

ENGINEERING SPECIFICATION 11 QUINTA ACE 160 CONSTRUCTION The boiler will be a wall-hung type condensing boiler which may also be installed free-standing on a suitable frame. The single piece, cast aluminium heat exchanger and other major components are contained within a sealed air box. The boiler casing shall be complete with a removable front section for maintenance purposes. Electrical and electronic controls will be contained within the instrument panel mounted in the drop-down lower front panel. This control panel will be HYDRAULIC, GAS AND FLUE CONNECTIONS condensate connections located at the bottom. The boiler will be be designed for central heating and indirect hot water production up to four bar. The boiler will be suitable for use on sealed systems and open-vented installations. OPERATION The boiler will be complete with a modulating control system that limits the maximum difference in temperature between the pre-mix burner with the gas/air ratio control system controlled internally. An intelligent, advanced boiler control will continuously monitor the boiler conditions, varying the heat output to suit the system load. The control will be able to react to external negative problems), maintaining boiler output for as long as possible happen in the system the boiler shall reduce its output and/or shut down (shut-off mode), awaiting the negative conditions to return to normal before re-starting. The control cannot override will activate below 7 C with stage one activating system/shunt CONTROLS The boiler will include a controls package that allows the actual and set values to be read and adjusted on the built-in digital display which also provides normal operating and fault code indication. The controls will come as standard with the following inputs/outputs: DHW temperature input High limit lock out Low water protection Outside sensor (optional) External shunt pump control External system pump control Fault alarm output DHW 3-port valve control or pump Open Therm connection. FEATURES Ultra-low NO x <35mg/kWh Fully modulating Quiet operation <52dB(A) LED illuminated interior Automatic maintenance warning PC connection ErP compliant Relay kit (optional) Premix burner and directives: 90/396EEC Gas appliances directive voltage directive 89/336/EEC E.M.C. directive ErP compliant

QUINTA PRO DIMENSIONS AND CONNECTIONS The complete range of Quinta Pro 30, 45, 55, 65, 90 and 115 boilers have a compact design of h750 x w500 x d500mm. KEY 191 Connection of the combustion Ø 80mm ( 45kW) Ø 100mm ( 55kW) Connection of the air intake pipe; Ø 125mm ( 45kW) Ø 150mm ( 55kW) Siphon connection bush Heating circuit return; 1¼ Male thread (32mm) Gas connection; ¾ Male thread (22mm) 500 500 100 1¼ Male thread (32mm) 750 130 191 365 50 50

DIMENSIONS AND CONNECTIONS 13 QUINTA ACE 160 DIMENSIONS AND CONNECTIONS KEY Flue gas outlet connection; Ø 100mm 143 Air supply connection; Ø 150mm Siphon connection 32mm Flow connection; 1¼ Male thread (32mm) Return connection; 1¼ Male thread (32mm) Gas connection; 1 Male thread (28mm) 226 602 600 1045 80 240 300 425 110

QUINTA PRO TYPICAL INSTALLATION Time/temp control 230v 6.3 amp supply Condensate Gas Flow Return X1 1 3 2 Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 BR BL GN/YW OT BL RL Tout Tdhw Pump hws/3wv Egv Status Status Status PUMP X81 BR BL GN/YW Factory fitted fly lead Time/temp control (volt free) Pump PM1 Alternative 0-10v control Alternative pump PM1 Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

TYPICAL INSTALLATION 15 QUINTA PRO TYPICAL INSTALLATION Room stat 2 Channel time clock Wiring centre 230v supply Gas Condensate DHW thermostat Flow DHW zone valve c/w end switch Htg zone valve c/w end switch By-pass valve Return Satisfied Cylinder thermostat DHW zone valve End switches close on valve fully open Calling Room thermostat Calling Satisfied HTG zone valve Wiring centre Factory fitted supply lead to be connected to a 230v fused spur for boiler permanent supply Time clock with two live switched outputs DHW on 230v HTG on 230v E N L BR BL GN/YW Live supply to boiler 1 3 2 System pump On/off Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 Shunt OT BL RL Tout Tdhw Pump hws/3wv Egv Status Status Status PUMP X81 230v 6.3 amp switched fuse spur

QUINTA PRO TYPICAL INSTALLATION Time/temp control 230v supply Pump SH1 Condensate Pump PM1 Gas Flow Return X1 1 3 2 BR BL GN/YW Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 PUMP OT BL RL Tout Tdhw X81 Pump hws/3wv Egv Status Status Status BR BL GN/YW Factory fitted fly lead Time/temp control (volt free) Pump PM1 Alternative 0-10v control Shunt pump SH1 Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

TYPICAL INSTALLATION 17 loss header. 3-way valve DHW priority Quinta Pro 30/45/55/65 only. QUINTA PRO TYPICAL INSTALLATION Time/temp control 230v supply Pump SH1 DHW thermostat Condensate Pump PM1 A AB B Gas Flow Bypass valve Diverting valve 2 port spring return valve Return X1 1 3 2 BR BL GN/YW Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 PUMP OT BL RL Tout Tdhw X81 Pump hws/3wv Egv Status Status Status BR BL GN/YW Factory fitted supply lead to be connected to a 230v fused spur for boiler permanent supply Time/temp control HTG (volt free) Time control DHW (volt free) 2 port spring return valve 230v fused supply for 2 port valve (connected to boiler supply) Wiring detail of controls when using a Remeha Calorifier, a volt free HWS time control and a 2 Port spring return valve. If using a different type of calorifier, please follow manufacturer s instructions regarding control and wiring details 3 way valve Pump PM1 Cylinder thermostat Boiler Tdhw HWS time control 230v fused supply (connected to boiler supply) Live Neutral Boiler signal out (volt free) Boiler signal in (volt free) Thermostat Safety limiter 2 C 1 2 C 1 Orange Grey Blue Brown 2 port spring return motorised valve Shunt pump SH1 Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

low loss header. Pumped option, DHW priority can be used on all Quinta Pro range (see page 22). QUINTA PRO TYPICAL INSTALLATION Time/temp control 230v supply Pump SH1 DHW thermostat Pump PM2 Condensate Pump PM1 Gas Flow Bypass valve 2 port spring return valve Return X1 1 3 2 Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 BR BL GN/YW OT BL RL Tout Tdhw Pump hws/3wv Egv Status Status Status PUMP X81 BR BL GN/YW Factory fitted supply lead to be connected to a 230v fused spur for bolier permanent supply Time/temp control HTG (volt free) Time control DHW (volt free) 2 port spring return valve 230v fused supply for 2 port valve (connected to boiler supply) Cylinder thermostat Pump PM1 Pump PM2 Shunt pump SH1 Wiring detail of controls when using a Remeha Calorifier with a 2 port spring return valve. If using a different type of calorifier, please follow manufacturer s instructions regarding control and wiring details Boiler Tdhw HWS time control Contractor or relay required if both pumps PM1 and SH1 loading exceed 1.5 amps 230v fused supply (connected to boiler supply) Live Neutral Boiler signal out (volt free) Boiler signal in (volt free) Thermostat Safety limiter 2 C 1 2 C 1 Orange Grey Blue Brown 2 port spring return motorised valve Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

TYPICAL INSTALLATION 19 QUINTA PRO TYPICAL INSTALLATION Normal position for the isense controller mounted in reference room within the building (room compensation) 230v supply 100m Max 1.6M Suggested height in room Pump PM1 Condensate Gas Flow Return X1 1 3 2 BR BL GN/YW Main control PCB OT BL RL Tout Tdhw PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 Pump hws/3wv Egv Status Status Status PUMP X81 BR BL GN/YW OT Factory fitted on/off or supply lead to modulating controls be connected to a 230v fused spur for boiler permanent supply Pump PM1 Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

QUINTA PRO TYPICAL INSTALLATION Normal position for the controller mounted in reference room within the building Outside sensor on North facing wall 100m Max Pump PM1 100m Max 230v supply 1.6M Suggested height in room isense can be fitted in the boiler if used for weather compensation only Condensate Gas Flow Return X1 1 3 2 BR BL GN/YW Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 OT BL RL Tout Tdhw Pump hws/3wv Egv Status Status Status PUMP X81 BR BL GN/YW OT on/off or Factory fitted modulating controls supply lead to be connected to a 230v fused spur for boiler permanent supply Outside sensor Pump PM1 Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

TYPICAL INSTALLATION 21 Heating room or outside weather compensated with Pro 30/45/55/65 only. QUINTA PRO TYPICAL INSTALLATION Normal position for the controller mounted in reference room within the building (room compensation) 100m max 100m max 230v supply 1.6M Suggested height in room Pump PM1 DHW sensor Condensate AB A B DHW diverting valve Gas Flow 2 port spring return valve Bypass valve Return X1 1 3 2 BR BL GN/YW Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 OT BL RL Tout Tdhw Pump hws/3wv Egv Status Status Status PUMP X81 BR BL GN/YW OT Factory fitted on/off or modulating controls supply lead to be connected to a 230v fused spur for boiler permanent supply 2 port spring return valve Outside sensor Calorifier sensor 3 way valve Boiler parameter P37 must be set to 0 Pump PM1 230v fused supply for 2 port valve Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

Heating room or outside weather compensation with used on all Quinta Pro range. QUINTA PRO TYPICAL INSTALLATION Normal position for the controller mounted in reference room within the building (room compensation) 100m max Outside sensor on North facing wall Pump PM1 230v supply 100m max 1.6M Suggested height in room isense can be fitted into boiler control panel for outside weather compensation only Pump PM2 DHW sensor Condensate Gas Flow 2 port spring return valve Bypass valve Return X1 1 3 2 Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 BR BL GN/YW OT BL RL Tout Tdhw Pump hws/3wv Egv Status Status Status PUMP X81 BR BL GN/YW OT Factory fitted supply lead to be connected to a 230v fused spur for boiler permanent supply on/off or modulating controls 2 port spring return valve Outside sensor Calorifier sensor Pump PM1 Pump PM2 Boiler parameter P37 must be set to 0 230v 3 amp fuses supply for 2 port valve Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

TYPICAL INSTALLATION 23 Multiple Quinta Pro boilers, heating only, outside weather or with a low loss header (optimising/weather compensated). QUINTA PRO TYPICAL INSTALLATION Normal position for the controller mounted in reference room within the building 100m max Outside sensor on North facing wall 230v supply Shunt pump Shunt pump Celcia MC4 230v supply 100m max 1.6M Suggested height in room isense can be mounted in boiler for weather compensation only Two to four boilers Condensate Gas Flow Return Pump PM1 Htg flow sensor X1 1 3 2 BR BL GN/YW Main control PCB PCB - SCU - S02 PCB - SCU - X01 PCB - IF 01 OT BL RL Tout Tdhw Pump hws/3wv Egv Status Status Status PUMP X81 isense mounted in reference room (or boiler for weather compensation only) OT - BUS DIGI Outside sensor on North facing wall 100 max Boiler No. 1 BR BL GN/YW Factory fitted supply lead to be connected to a 230v fused spur for boiler permanent supply Shunt pump On/off Shunt pump On/off Shunt pump On/off OT OT OT System pump PM1 (Max 1amp) Shunt pump Switch spur 230v Rated at 3 amps MC4 X81 X81 X81 L N E E 17 18 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Boiler No.4 Boiler No.3 Boiler No.2 Flow sensor mount on flow pipework to register a comon flow temperature Note: Control PCBs are shown diagrammatically. Earths are omitted for clarity.

QUINTA ACE 160 TYPICAL INSTALLATION Hot water cylinder Note: This information is indicative.

TYPICAL INSTALLATION AND ELECTRICAL INSTALLATION AND CONTROLS 25 ELECTRICAL INSTALLATION AND CONTROLS QUINTA RANGE GENERAL The Quinta Range is supplied as standard with electronic designed microprocessor at the heart of the control system. SPECIFICATIONS ELECTRICAL SUPPLY The Quinta Range must have a permanent 230V/50Hz single phase supply rated at 6.3 amps. The control unit is not phase/neutral sensitive. CONTROL BOX Electrical rating: 10VA Pump run on (HTG): 1-98 minutes FUSE SPECIFICATION The boiler is protected by fuses: F1 rated at 6.3 amps (slow acting) F2 230V, 2 amps (fast acting) Fan 230V. BOILER TEMPERATURE CONTROL The Quinta Range has electronic temperature control with can be adjusted between 20 and 90 C. HIGH LIMIT TEMPERATURE PROTECTION The high limit, temperature protection device switches off and limit set point (set by boiler type). When the fault is corrected the boiler can be restarted by using the reset key on the control panel. LOW WATER PROTECTION (FLOW AND CONTENT) The Quinta Range is supplied with a low water protection on the basis of a low water pressure switch and also by temperature measurement. By modulating down at the moment that the water long as possible. CONNECTING A THIRD PARTY CONTROL UNIT TO A STANDARD BOARD PCB (PCUS-01) Main PCB control all included as standard. PCB (IF-01) 0-10V control. PCB (SCU-X01) This has two volt free contacts, which can Depending on the setting, a maximum of two messages about the status of the boiler can be transmitted. PCB (SCU-S02) F 4AT X1 SCU-S02 On/off OT BL RL Tout Tdhw 1 2 % IF-01 X5 X4 SCU-X01 Status Status NcCNo NcCNo X2 Status 0-10 0-10 NcCNo OTm 0 + 0 + NcCNo OTm 0 + 0 + For control of external central heating pump (pump) and control of external three-way valve (3wV). Other features available. X3 NcCNo NcCNo X3 X2 X2a EXTERNAL CONNECTIONS All external connections are made to any one of the standard supplied PCBs depending on the type of control and external X1 X3 Pump 3wV EgV N L NCD N L Pump N L NCD N L X4 Status NcCNo NcCNo X5 Tsol Gps Tsol Gps Hru Hru

BOILER CONTROLS The Quinta Range can be controlled using a number of methods examples of some are given below. Please contact our sales or technical departments for further options. MODULATING (TWO WIRE CONTROL) When using the optional Remeha compensating controllers the heat output modulates between the minimum and maximum applies to both single and multiple boiler installations, under the dictates of a room and/or outside temperature sensor. isense Pro multi-boiler multi zone optimising/compensating controller can control up to ten boilers, two heating zones either VT or CT and one domestic hot water circuit. isense controller single-boiler (option for multiple boiler) single zone optimising/compensating controller. Remeha MC4 provide step control for multi-boiler installation of up to four boilers. Analogue control (0-10V d.c.). The heat output modulates between the minimum and the maximum values on the basis of the voltage supplied by an external analogue (0-10V) input. ON/OFF VOLT FREE CONTROL FROM A THIRD PARTY INSTALLER Connect a two wire cable to terminals on/off OT which must be a volt free connection from the third party controller. ANALOGUE HEAT OUTPUT-BASED CONTROL (%) The 0-10V signal controls the boiler output between 0% and 100% of its total capacity (kw). The minimum and maximum values are limited. The minimum output is linked to the boiler s modulation depth. The output varies between the minimum and maximum value on the basis of the value determined by the controller. 0-1.5 0-15 Boiler off 1.5-1.8 15-18 Hysteresis 1.8-10 18-100 Temp required 0-1.5 0-15 Boiler off 1.5-1.8 15-18 Hysteresis 1.8-10 18-100 Heat output requested ANALOGUE TEMPERATURE-BASED CONTROL 0 C and 100 C. This control modulates on the basis of the temperature set point calculated by the controller sent by the A jumper 2 (see table opposite) on the interface is used to select either temperature control or heat output control (%).

BOILER CONTROLS 27 PRIORITY DHW CONTROL TEMPERATURE CONTROL With a Remeha temperature sensor or with a standard (volt free) DHW thermostat. option is used. With a three-way diverting valve (not Q90/115) With a DHW pump Untimed (available 24 hours a day). SYSTEM/SHUNT PUMP A shunt pump can be connected to the boiler (maximum input the heating return connection and be as close to the boiler as possible. A system pump can also be connected to the boiler FROST PROTECTION system is activated as follows: below 7 C system pump is switched on if connected to the boiler. Below 3 C boiler is pump switch off. Note: This control is designed to protect the boiler for full system protection use a frost thermostat or a weather compensator. REMOTE ALARM AND BOILER RUN INDICATION As standard, the boiler is supplied with two volt free indicators common alarm signal and boiler run signal. Maximum 230 volts, SAFETY INTERLOCKS As standard the boiler is supplied with shutdown (BL) and release (RL) inputs via the main PCB control. SYSTEM WATER specialist water treatment companies in respect to aluminium heat exchangers. For further information Remeha Water Quality Regulations is available from remeha.co.uk The recommendations in the document must be followed.

QUINTA ACE SPECIFICATIONS 29 QUINTA ACE 160 SPECIFICATIONS The boiler has a three-wire mains lead (lead length 1.5m) and is suitable for a 230VAC/50Hz power supply with a phase/neutral/ earth system. The boiler is not phase sensitive and the boiler is completely pre-wired. ASSEMBLY OF THE CONTROL PANEL The optional PCBs are also placed in the connection box. X07 X06 X08 X05 X09 X10 X04 X03 X11 X021 X2 B C X02 X01 X12 Connectors from the control unit CUGH (Front view) Control panel CU-GH & HMI X01 1-7 X02 1-9 X03 1-15 1 X04 / X05 1-15 X06 1-4 X07 1-4 X08 1-13 X09 1-4 X10 1-4 X11 1-4 X12 1-5 X012 X013 X022 X021 X041 X051 X053 X054 X055 X081 X071 X083 X121 X122 2 3 4 X011 7 X20 8 X202 9 10 11 12 13 14 15 16 X07 X06 X04 / X05 17 18 19 X015 X016 X0141 X014 5 230V, 50Hz 6 X201 EMC X031 X032 X08 X09 X10 X11 X12 X03 X02 X01 KEY 1 Boiler control unit 8 Control fascia panel 15 Air pressure differential switch 2 Lighting 9 Fan supply 16 Flue gas sensor 3 Ignition probe 10 17 4 Ignition transformer 11 Flow sensor 18 Gas valve 1 5 12 19 Gas valve 2 6 N/a 13 Return sensor 7 Service connector/computer connection 14 Hydraulic pressure sensor

FLUE OPTIONS 31 FLUE OPTIONS available for the room-sealed CLV system. The concentric system can be supplied for individual boilers for horizontal or vertical installation. Because of the excess fan (depending on the boiler model and actual route taken), which enables the installer to position the boiler almost anywhere in the building. with bird guard. Care should be taken when siting the actual discharge point as a vapour plume will be visible when the boiler is operating and it is possible for water to drip to the ground from the terminal on horizontal installations, which could turn to ice in freezing conditions. GUIDELINES maintenance of ventilation for gas appliances not exceeding 70kW (1st, 2nd and 3rd family gases). appliances to chimneys and for maintenance of chimneys not exceeding 70kW (1st, 2nd and 3rd family gases). water boilers of rated inputs between 70kW to 1.8MW (net) (2nd and 3rd family gases). industrial and commercial premises. IMPORTANT NOTE drain/siphon, this must be connected within one metre of the condensate collector. Where boilers have been installed on a seal water type with discharge taken to a suitable drain point. Flue components are constructed from a white painted metal outer and plastic inner. Flue terminals are painted as detailed in the terminal diagrams. Plume kit external components are aluminium or plastic and are painted black.

QUINTA RANGE FLUE OUTLET/AIR INLET DETAILS The Quinta Range of boilers are supplied as standard with a system connected to the inner concentric connection with the air supply taken from the boiler house via the outer concentric connection. operation and an option using single skin is available. DETAILS OF INLET CONNECTION Flue gas Air in DETAILS OF CONDENSATE DRAIN To suitable drain point TO SUITABLE DRAIN POINT

FLUE OPTIONS 33 QUINTA PRO 30 AND 45 ROOM-SEALED, 80/125MM HORIZONTAL CONCENTRIC FLUE KIT OPTION QP01 installed immediately above another. For two boilers only, it is also possible to install the external terminal wall plates touching each other. Kit parts MG410082982 (max wall thickness 500mm) 1 x horizontal terminal Note: Boiler bend and wall plate are included HORIZONTAL FLUE KIT 80/125MM passing through hole in wall to ensure correct positioning 240mm Sq. 4 x 5mm holes 204 Sq Clearance hole for terminal through wall 130mm Note: 140mm diameter the inside wall to allow clearance for the bend Cut terminal on site to suit wall thickness Max 1000mm Min 150mm Kit parts MG410081940 (extended version max wall thickness 1000mm) 1 x horizontal terminal Note: Boiler bend and wall plate are included EXTENDED HORIZONTAL FLUE KIT 80/125MM 50mm insertion length into mating socket 50mm insertion length into mating socket 110mm RAL colour 7021/9016 125mm o/d 240mm Sq. 145mm 95mm 150(min)600/1000(max) 80mm o/d 740/1135mm 4 x 5mm holes 204 Sq MG410082982 and MG410081940

FLUE OPTIONS 35 QUINTA PRO 30 AND 45 ROOM-SEALED, 80/125MM VERTICAL CONCENTRIC FLUE KIT OPTION QP03 Kit parts KT1215 (max wall thickness 500mm) 1 x vertical terminal MG410086864 1 x universal roof seal pack VE001 CONCENTRIC VERTICAL FLUE KIT 80/125MM Weathering slate suitable Additional components (within boiler constraints) Condensate drain QP3 0/45/55/65/90/115 = 100mm QP30/45-495mm CONCENTRIC VERTICAL FLUE KIT 80/125MM VERTICAL FLASHING DETAIL 25mm I/D - 32mm O/D 180mm 87-90 Condensate drain Part No. MG410084472 RAL- 7021 (300mm) 1350mm 80mm approx 600mm x 500mm Cut down to suit diameter of terminal use RAL- 9016 755mm Can be cut down on site to a minimum of 150mm. Retain the difference between inner and outer. Dn80 Dn125 Detail of standard weathering plate for 100mm to 150mm

QUINTA PRO 30 AND 45 80/125MM ROOM-SEALED CALCULATED DATA TO DETERMINE MAXIMUM FLUE RUNS Metres 20 20 Reduction length for each 45 bend Metres 1 1 Reduction length for each 90 bend Metres 2 2 Metres 6 6 Note: Minimum fall back is 2 o or 50mm per metre. Note 2: The components listed below are not for external use. 'L' 125 o/d 'L' Internal seal (80mm) Part No. MG410027355 268 ± 3 125 o/d Siphon Part No. MG410081165 50 80 o/d 80 o/d Standard length (cannot be cut) 'L' = 1000mm Part No. MG410084486 'L' = 500mm Part No. MG410084485 Standard length (cuttable length) 'L' = 1000mm Part No. MG410082314 'L' = 500mm Part No. MG410082313 Internal wall plate Part No. MG410081302 Siphon adaptor kit Part No. MG410087491 25mm I/D - 32mm O/D 125 i/d 145 95 110 125 i/d DN125 87-90 180mm 80mm o/d 80 o/d 7 10 M8 100 50 Condensate drain Part No. MG410084472 45 Bend Part No. MG410084461 90 Boiler short bend Part No. MG410084810 90 Bend Part No. MG410084460 Extended wall bracket Part No. MG410084481 126 i/d 115 158mm 210 60 ctrs Wall bracket Part No. MG410087863 Clamp band Part No. MG410087654 (one supplied with each component except MG410084810) 80/125mm - 100/150mm Concentric adaptor Part No. MG410084475 Note 3: All dimensions are in mm.

FLUE OPTIONS 37 QUINTA PRO 30 AND 45 ROOM-SEALED, 100MM TWO ZONE CLV FLUE KIT OPTION QP04 Connection in areas of different pressure (C53, C83). Combustion air supply and combustion gas discharge are possible in various pressure zones, semi-clv system, with the exception of coastal areas. The maximum permissible difference in height between the combustion air supply and the combustion gas discharge is 36m. Kit parts KT032 1 x air inlet PU002 1 x condensate drain MG410085130 1 x siphon MG410081165 1 x condense adaptor kit MG410087491 CLV FLUE KIT 80/125MM 100mm aluminium single wall Flue outlet T 36m (maximum height) Fall to boiler Fall from boiler Air inlet Condensate drain Quinta Pro 30/45 two pipe adaptor Flue discharge: diameter 100mm length 40m Flue terminal c/w bird guard 100/80mm reducers to adapt boiler to suit Detail of the 100mm two zone CLV Flue Kit Option QP04 (Part No. KT032) Only parts named are in the kit additional 100mm single wall pipe and bends, shown dotted will be needed to suit site Please contact our technical department for advice. Air inlet guard Condensate drain 100-80mm reducer x2 Two pipe adaptor plate

CONVENTIONAL FLUE QUINTA PRO 30 AND 45 100MM CONVENTIONAL OR OPEN-FLUE SYSTEMS Typical single-boiler installation. Ensure that the overall route does not exceed the maximum values in the table on page 40. CONVENTIONAL OR OPEN FLUE SYSTEMS Flue outlet 100mm aluminium single wall flue system Fall to boiler Refer to table on page 39 Air from plant room Condensate drain 100/80mm reducer to adapt boiler to suit 100mm system Detail of standard weathering plate for 100mm to 150mm Cut down to suit dia. of flue 80mm approx 600mm x 500mm

FLUE OPTIONS 39 QUINTA PRO 30 AND 45 100MM CONVENTIONAL OR OPEN-FLUE SYSTEMS The components listed below are only suitable for internal use as illustrated on pages 37 and 38. As the boiler Metres 40 40 Reduction length for each 45 bend Metres 1.4 1.4 Reduction length for each 90 bend Metres 4.9 4.9 101 i/d 50 101 i/d 15mm ID/32mmO/D 100 o/d 'L' L = 1000mm Part No. MG87062 L = 500mm Part No. MG87061 L = 250mm Part No. MG87060 80 o/d 10 Reducer 80mm spigot to 100mm Part No. MG87127 connection to adapt to 100mm system Top 60 200 101 i/d Part No. PU002 100mm Condensate drain Part No. MG410085130 180mm 30 95 105 105 76 76 Note: 2 x 45 bends will offset to 71mm centres 20 101 i/d 10 Flue terminal c/w bird guard Part No. PU001 90 Bend Part No. MG87113 45 Bend Part No. MG87103 25-55mm 8mm x 45mm screw thread Part No. MG87183 Twin pipe adaptor plate Mounting bracket Part No. MG87193 Note: All dimensions are in mm.

QUINTA PRO 30 AND 45 PLUME KITS 80/125MM FLUE KIT OPTION QP05 point in line with current regulations. Kit parts PMK-horizontal terminal kit KT00335 1. PMK wall terminal 2. Boiler bend not illustrated 3. Wall plates 4. Plume extension 6. 90 bend (80mm) 7. Flue outlet (80mm) 8. Bird guard 1 x siphon MG410081165 (not illustrated) 1 x condensate adaptor kit MG410087491 (not illustrated) HORIZONTAL FLUE KIT 80/125MM Max 2000mm Min 150mm 5 6 8 7 Core drill wall 130mm diameter Horizontal terminal plume kit assembly 5 4 with regards to the minimum distances from openings, walls, etc. Flue can be taken directly through rear outside wall or discharged through a side wall left or right. Both must be within the constraints in the table below. 1 3 80/125mm Plume Management details. Calculations based on products supplied by Remeha. 3 Metres 6 6 Reduction length for each 45 bend Metres 1.0 1.0 Reduction length for each 90 bend Metres 2.0 2.0 Note: The table shows the maximum lengths allowed. Both the boiler bend (90 @ 80/25mm concentric) at the spigot and the PMK terminal bend reduction in lengths. The external components for this PMK are constructed of black aluminium. Note 2: The combination of internal concentric and external PMK must not exceed the overall concentric maximum.

PLUME KITS 41 80/125MM PLUME MANAGEMENT COMPONENTS PART DETAIL Note: The components listed below must only be used as part of the Plume Management Kit. PMK-horizontal Terminal not supplied as a separate component MG410082343 PMK 90 bend (80mm) MG410082344 PMK horizontal outlet (80mm) MG410082341 MG410082342 PMK 45 bend (80mm) MG410082345 Bird mesh (80mm) MG410087191 PMK wall bracket (80mm) MG410084810 Boiler bend (80mm)

QUINTA PRO 30 AND 45 MULTI-BOILER INSTALLATION ON A COMBINED HEADER INSTALLATION ON A COMBINED HEADER 80mm boiler connections Tapered cone c/w bird guard For illustration purposes only.

PLUME KITS 43 QUINTA PRO 30 AND 45 MULTI OR SINGLE-BOILER INSTALLATION ON A FLUE DILUTION SYSTEM boilers to prevent the dilution fan affecting the gas/air ratio control system in the boiler. INSTALLATION ON A FLUE DILUTION SYSTEM 80mm boiler connections Bellmouth 2 x D + 50mm D Opening in duct 2 x D 30mm Drain Typical duct entry detail

QUINTA PRO 55, 65, 90 AND 115 AND QUINTA ACE 160 ROOM-SEALED, 100/150MM HORIZONTAL CONCENTRIC FLUE KIT another. When installing two boilers only, it is also possible to install the external terminal wall plates touching each other. Kit parts MG4100828921 (max wall thickness 500mm) 1 x horizontal terminal Note: boiler bend and wall plate are included HORIZONTAL FLUE KIT 100/150MM Wall closure plate should be fitted to terminal before passing through hole in wall to ensure correct positioning 240mm Sq. 4 x 5mm holes 204 Sq Clearance hole for terminal through wall 155mm Note: 170mm diameter recess 20mm deep required from the face of the inside wall face to allow clearance for the bend Note: Cut terminal on site to suit wall thickness max 500mm min 150mm Kit parts MG410081941 (extended version max wall thickness 1000mm) 1 x horizontal terminal Note: boiler bend and wall plate are included EXTENDED HORIZONTAL FLUE KIT 100/150MM 45mm insertion length into mating socket 115 BS RAL colour 9016 / 7021 150 o/d 240 Sq 140 Note: All dimensions are in mm. 100 o/d 150(min)-500/1000(max) 790/1135 HRS room sealed terminal 100/150 MG410082981 & MG410081941 4 x 5mm holes 204 Sq Detail of the 100/150mm horizontal concentric

FLUE OPTIONS 45 QUINTA PRO 55, 65, 90 AND 115 AND QUINTA ACE 160 ROOM-SEALED, 100/150MM VERTICAL CONCENTRIC FLUE KIT Kit parts KT1216 1 x vertical terminal MG410084862 1 x universal roof seal pack VE001 Kit parts KT00310 Contains optional condensate drain VERTICAL FLUE KIT 100/150MM Weathering slate suitable Detail of the vertical 100/150mm Concentric Flue Kit (KT1216) Can be cut on site to a minimum of 150mm minimum of 10mm QP55/65/90/115 615mm site details (within boiler constraints) Condensate drain QP55/65/90/115 = 100mm Dn100 Dn150 10 65 580 RAL- 7021 RAL- 9016 1735 80 approx 600 x 500 Cut down to suit diameter of terminal in use

QUINTA PRO 55, 65, 90 AND 115 AND QUINTA ACE 160 100/150MM ROOM-SEALED CALCULATION DATA TO DETERMINE MAX FLUE RUNS Metres 20 18 17 13 6 Reduction length for each 45 bend Metres 1.0 1.0 1.0 1.0 1.0 Reduction length for each 90 bend Metres 2.0 2.0 2.0 2.0 2.0 o or 50mm per metre. Note 2: The components listed below are not for external use. 150 o/d 268 ± 3 150 o/d 50 100 o/d Cuttable length 1000mm Part No. MG410082318 500mm Part No. MG410082317 Internal wall plate Part No. MG41410081303 Siphon Part No MG410081165 100 o/d Standard length 1000mm Part No. MG410084336 500mm Part No. MG410084335 150mm Offset Silicon seal ring (flue side) Part No. MG410027356 Siphon adaptor kit Part No MG410087491 150 115 150 i/d 128 150 115 150 i/d DN150 151 i/d 90 bend Part No. MG410084310 147 100 o/d 50 45 bend Part No. MG410084313 100 o/d 90 boiler short bend Part No. MG410084360 (clamp not required) 25mm i/d 32mm o/d 7 10 M8 100 50 Extended wall bracket Part No. MG410084331 210 115 180mm 87-90 60mm ctr s Wall bracket Part No. MG410087915 Clamp band Part No. MG410087656 (one supplied with each component except MG410084360) Condensate drain Part No. MG410084322 Note 3: All dimensions are in mm.

FLUE OPTIONS 47 QUINTA PRO 55, 65, 90, 115 AND QUINTA ACE 160 ROOM-SEALED TWO ZONE CLV FLUE KIT Connection in areas of different pressure (C53, C83). For the Quinta Ace 160, the boiler can be installed on C43 systems Combustion air supply and combustion gas discharge are possible in various pressure zones, semi-clv systems. With the exception of coastal areas, the maximum permissible difference in height between the combustion air supply and the combustion gas discharge is 36m. Kit parts KT030 1 x air inlet PU002 1 x condensate drain MG4100851301 x siphon MG4100811651 x condense adaptor kit MG410087491 TWO ZONE FLUE KIT 100/150MM 100mm aluminium single wall flue and air inlet system Max length see boiler technical booklet Flue outlet Fall to boiler T 36m (maximum height) Air inlet Fall from boiler Condensate drain Condensate drain Different CLV flue configurations may be available. Please contact our technical department for advice. 27 16 17 14 40 Equivalent length of 45 o elbow (M) 1.4 1.4 1.4 1.4 1.2 Equivalent length of 90 o elbow (M) 4.9 4.9 4.9 4.9 2.1

QUINTA PRO 55, 65, 90, 115 AND QUINTA ACE 160 CONVENTIONAL OR OPEN-FLUE SYSTEMS CONVENTIONAL OR OPEN FLUE SYSTEMS Flue outlet 100mm aluminium single Fall to boiler 50mm / M Air from plant room Condensate drain 39 26 24 19 8 40 Reduction length for each 45 bend (M) 1.4 1.4 1.4 1.4 1.4 1.2 Reduction length for each 90 bend (M) 4.9 4.9 4.9 4.9 4.9 2.1 Please refer to Remeha technical department for further details. *Not supplied by Remeha.

FLUE OPTIONS 49 100MM SINGLE WALL ALUMINIUM FLUE COMPONENTS ALUMINIUM FLUE COMPONENTS 101 i/d 80 approx Cut down to suit diameter of ue in use and seal with silicone supplied 50 600mm x 500mm Detail of standard weathering plate for 100mm to 150mm ue (Part No. VE001) 'L' 101 i/d 30 95 10 100 o/d 125 20 101 i/d Flue terminal c/w bird guard Part No. PU001 Standard length L = 1000mm Part No. MG87062 L = 500mm Part No. MG87061 L = 250mm Part No. MG87060 80 o/d Reducer 80 spigot to 100 socket Part No. MG87127 Must be used on the QP 30/ e connection to adapt to 100mm system Top 200 105 105 90 bend Part No. MG87113 76 76 45 bend Part No. MG87103 Note: 2 x 45 bends will offset to 71mm centres 25-55mm 10 60 101 i/d Air inlet guard Part No. PU002 268 ± 3 25mm ID/32mmO/D 180mm Mounting bracket Part No. MG87193 8mm x 45mm screw thread Silicon seal ring Part No. MG87183 Siphon Part No. MG410081165 100mm Condensate drain Part No. MG410085130 Eccentric flue connector 80/80 Part No. S100250 100/100 Part No. S101626 Siphon adaptor kit Part No. MG410087491 Note: All dimensions are in mm. Note 2: The only parts that are suitable for external use are VE001, PU001 and PU002.

QUINTA PRO 55, 65, 90 AND 115 AND QUINTA ACE 160 PLUME KITS 100/150MM FLUE KIT OPTION QP11 Plume kit termination positions must not be used to circumvent current standards and regulations. The point of exit determines the discharge point, again in line with current regulations. 100/150mm Plume Management Kits QP11 Kit part KT00336 PMK-horizontal terminal kit 1. PMK wall terminal 2. Boiler bend not illustrated 3. Wall plates 6. 90 bend (100mm) 7. Flue outlet (100mm) 8. Bird guard 1 x siphon MG410081165 not illustrated 1 x condense adaptor kit MG410087491 not illustrated FLUE KIT OPTION Wall depth max 500mm min 150mm Terminal inner and outer can be cut to suit. face of the inside wall surface to allow clearance for the bend. Max 2000mm Min 150mm 5 6 8 7 Core drill wall 155mm Diameter Horizontal terminal kit installed 4 5 5 6 8 1 Flue can be taken directly through rear outside wall or discharged through a side wall, left or right. Both must be within the constraints listed in the table below. 3 3 6 6 6 6 6 Reduction length for each 45 bend (M) 1.2 1.2 1.2 1.2 1.2 Reduction length for each 90 bend (M) 2.8 2.8 2.8 2.8 2.8 Note: The table shows the maximum lengths allowed. Both the boiler bend (90 @ 100/150mm concentric) at the spigot and the PMK terminal bend (90 @ 100mm single Note 2: The combination of internal concentric and external PMK must not exceed the overall concentric maximum.

PLUME KITS 51 100/150MM PLUME MANAGEMENT COMPONENTS PART DETAIL COMPONENTS PART DETAIL PMK horizontal terminal Not supplied as a separate component MG410081752 PMK 45 bend (100mm) MG410081755 Bird mesh 100mm MG410081753 PMK 90 bend (100mm) Dn 100 MG410087193 PMK wall bracket (100mm) MG410081754 PMK horizontal outlet (100mm) MG410084360 Boiler bend MG410081751 PMK 1000mm glue extension piece c/w wall bracket (100mm) Note: The components listed below must only be used as part of the Plume Management Kit.

QUINTA PRO 55, 65, 90 AND 115 AND QUINTA ACE 160 MULTI OR SINGLE-BOILER INSTALLATION ON A FLUE DILUTION SYSTEM ratio control system in the boiler. FLUE DILUTION SYSTEM 100mm boiler connections Bellmouth 2 x D + 50mm D Opening in duct 2 x D 30mm Drain Typical duct entry detail

PLUME KITS 53 QUINTA PRO 55, 65, 90 AND 115 MULTI-BOILER INSTALLATION ON A COMBINED HEADER MULTI BOILER INSTALLATION 100mm boiler connections Tapered cone c/w bird guard

DN 150 FLUECADE SYSTEM The Fluecade system can be used on all of the Quinta Pro boilers from two boilers up to a maximum of six in-line and back-to-back. components. Optional adaptors are available which can be connected to the last boiler connection. Refer to table on page 65. is supplied in 150mm and 200mm only, and is CE approved. Only the components and accessories listed on pages 25 and 32 FLUECADE SYSTEM Kit parts MG410121370 1. Air inlet grill 100-150, MG410075435 x 2 2. Extension PP 100 L = 500, MG410085481 x 2 3. Elbow short PP 100-90, MG410085141 x 2 4. Collector PP 150 1 x 100 45 L = 570, MG410121378 x 2 5. Extension PP 150 L = 500, MG410070321 x 1 6. Condensate trap PP 150, MG410070327 x 1 7. Cover PP 150, MG410070343 x 1 9. Wall bracket 150, MG410087196 x 3 7 6 5 4 3 9 8 2 CTC 530 1 DN 100

DN 150 QUINTA FLUECADE SYSTEM 55 THIS BASIC PP 150MM FLUECADE EXTENSION HEADER KIT IS SUITABLE FOR CONNECTING AN EXTRA QUINTA PRO BOILER IN AN IN-LINE CONFIGURATION IN-LINE CONFIGURATION Kit parts MG410121371 1. Air inlet grill 100-150 MG410087957 x 1 2. Extension PP 100 L = 500 MG410085481 x 1 3. Elbow short PP 100-90 MG410085141 x 1 4. Collector PP150 1 x 100 45 L = 570, MG410121378 x 1 5. Wall bracket 150 MG410087196 x 1 5 P=530 4 3 2 1 DN 100

THIS BASIC PP 150MM FLUECADE HEADER KIT IS SUITABLE FOR TWO QUINTA PRO BOILERS IN A BACK-TO-BACK CONFIGURATION Kit parts MG410076742 BACK-TO-BACK CONFIGURATION 10 5 4 8 12 3 11 6 7 1 2 KEY 1 2 3 Air inlet grill 100-150 -45 6 7 8-100 -150 11 12 Wall bracket 150 4-90 9 5 10

QUINTA FLUECADE SYSTEM 57 THIS PP 150MM FLUECADE EXTENSION KIT IS SUITABLE FOR TWO EXTRA QUINTA PRO BOILERS IN A BACK-TO-BACK CONFIGURATION Kit parts MG410076743 BACK-TO-BACK CONFIGURATION 8 4 7 3 5 6 1 2 KEY 1 4 7 2 3 Air inlet grill 100-150 5 6 8 Wall bracket 150

DN 200 THIS BASIC PP 200MM FLUECADE HEADER KIT IS SUITABLE FOR THE CONNECTION OF TWO QUINTA PRO BOILERS IN AN IN-LINE CONFIGURATION for the Quinta Pro range of boilers. Kit parts MG410121372 IN-LINE CONFIGURATION 6 5 4 3 8 7 CTC 530 2 1 DN 150 DN 100 KEY 1 2 3 Air inlet grill 100-150 4 5 6 7 8 Wall bracket 150

DN 200 FLUECADE KITS 59 THIS BASIC PP 200MM FLUECADE EXTENSION KIT IS SUITABLE FOR THE CONNECTION OF AN EXTRA QUINTA PRO BOILER IN AN IN-LINE CONFIGURATION for the Quinta Pro range of boilers. Kit parts MG410121373 IN-LINE CONFIGURATION P=530 4 3 2 5 1 DN 100 DN 150 KEY 1 2 Air inlet grill 100-150 3 4 5 Wall bracket 200

THIS BASIC PP 200MM FLUECADE HEADER KIT IS SUITABLE FOR TWO QUINTA PRO BOILERS IN A BACK-TO-BACK CONFIGURATION for the Quinta Pro range of boilers. Kit parts MG410076746 BACK-TO-BACK CONFIGURATION 9 10 4 7 11 3 5 6 1 2 KEY 1 2 3 4 Air inlet grill 100-150 5 6 7 8 9 10 11 Wall bracket 200

FLUECADE KITS 61 THIS BASIC PP 200MM FLUECADE EXTENSION KIT IS SUITABLE FOR TWO QUINTA PRO BOILERS IN A BACK-TO-BACK CONFIGURATION for the Quinta Pro range of boilers. Kit parts MG410076747 BACK-TO-BACK CONFIGURATION 4 7 8 3 5 6 1 2 KEY 1 4 7 2 Air inlet grill 100-150 5 8 Wall bracket 200 3 6

FLUECADE COMPONENTS Flue header 200mm Part No. MG410076748 Flue header 150mm Part No. MG410121378 Flue header 200mm Part No. MG410081949 Flue header 150mm Part No. MG410071511 Quinta Pro 30/45 80mm x 125mm boiler connection Part No. MG410076724 Air intake grill (parallel) 80mm Part No. MG410076039 Air intake grill (parallel) 100mm Part No. MG410079314 Air intake grill (concentric) 80/125mm Part No. MG410075434 Air intake grill (concentric) 100/150mm Part No. MG410075435 200mm 90 elbow Part No. MG410070411 150mm 90 elbow Part No. MG410070331

FLUECADE KITS FLUECADE COMPONENTS 63 FLUECADE COMPONENTS Wall bracket 200mm Part No. MG410087198 Wall bracket 150mm Part No. MG410087196 100mm 45 elbow Part No. MG410085142 90 elbow 100mm Part No. MG410085141 Part No. MG410085481 Condense adaptor Kit parts MG410087491 Condensate trap with drain point 150mm Part No. MG410081350 Condensate trap with drain point 200mm Part No. MG410071526 End cap PP 150mm (no drain point) Part No. MG410070343

FLUECADE 200mm PP roof terminal Part No. MG410070439 150mm PP roof terminal Part No. MG410070359 (can t use PP externally) 200mm chimney cap Part No. MG410087398 150mm chimney cap Part No. MG410085789 Ventilation grate 250mm x 300mm (175cm 2 ) Part No. MG410087433 Cover plate 300mm x 300mm with sleeve 250mm x 300mm Part No. MG410081362

FLUECADE COMPONENTS 65 DATA TO DETERMINE THE MAXIMUM LENGTH AND DIAMETER OF THE FLUECADE SYSTEM FOR THE QUINTA PRO RANGE OF BOILERS Heat input net kw 30.0 41.2 56.5 62 86 110.2 kw 150 150 120 100 160 220 50 50 50 50 50 50 CO 2 9.0 9.0 9.0 9.0 9.5 9.1 % 58.6/81.6 150 150 150 150 89.4/122.4 150 150 150 150 119.2/163.2 150 150 150 150 147/204 150 150 150 150 178.8/244.8 150 150 150 150 110.6 150 150 150 150 165.9 150 150 150 150 221.2 150 150 150 150 276.5 150 150 150 150 331.8 150/200 150/200 150/200 150/200 123 150 150 150 150 184.5 150 150 150 150 246 150/200 150/200 150/200 150/200 307.5 150/200 150/200 150/200 150/200 369 150/200 150/200 150/200 150/200 168.4 150 150 150 150 252.6 150 150 150 150 336.8 150 150 150 150/200 421 150/200 150/200 150/200 150/200 505.2 200 200 200 200 214 150 150 150 150 321 150 150/200 150/200 150/200 428 150/200 150/200 150/200 150/200 535 150/200 150/200 150/200 150/200 642 200 200 200 200 304.2 200 200 200 200 456.3 N/a N/a N/a N/a 608.4 N/a N/a N/a N/a 760.5 N/a N/a N/a N/a 912.6 N/a N/a N/a N/a 45 1.1m 1.5m 2m 90 2.5m 3.3m 4.9m Note 1: Length between shaft and last boiler = 1 metre. Note 2: For calculating other horizontal/vertical lengths between the last boiler and the vertical riser the height must be reduced by the number of lengths added to the horizontal over one metre and for any added bends the details in the table adjacent must be used. all joints are air and water tight. Note 4: 150/200mm means; horizontal = 150mm, vertical = 200mm.

CASCADE OPTIONS 67 CASCADE OPTIONS greater reliability for years. The compact design of the boilers, combined with the smart gas and water connection technology of the cascade system, makes it possible to install a high heat output in a small area. When installing two to eight boilers, our product range includes systems that are very comprehensive and easy to install. The hydraulic and gas system can be put together entirely without welding, using screw connections, compression connections are available for independent cascade installation. Please contact our technical or sales departments for different Quinta Pro 30, 45, 55, 65, 90, 115 boilers are particularly suitable for use in cascade systems due to their small footprint and width of only 50cm which allows an exceptionally compact 115 boilers in line (including low loss header), approximately only C). The cascade systems can be divided into three main groups: wall-mounted mounted on a free-standing frame mounted on a free-standing frame. The boiler side of the cascade systems is sized to 20ºC. The low loss header is based on 20/11ºC. STRUCTURE OF QUINTA PRO AND QUINTA ACE 160 CASCADE SYSTEMS wall or to a free-standing frame. The low loss header supplied A common PVC condensed water discharge pipe (not supplied) can be installed in the frame. For this purpose, holes have been

QUINTA PRO INSTALLATION DRAWINGS FOR WALL-MOUNTED CASCADE SYSTEMS The cascade systems can be divided into three main groups: The boiler side of the cascade systems is sized to 20ºC. The low loss header is based on 20/11ºC. QUINTA PRO 530 231 500 30 500 3680 100 1305 1576 2120 1590 325 125 KEY or 125/DIN 2631 (8 holes) B System return; connection DN 100 or 125/DIN 2631 (8 holes) X Y Low loss header Gas supply connection DN 50 or 65/DIN 2633 (4 holes) Distance to system return concentric connection DIMENSIONS (MM) 2 4 8 Width mm 1030 1560 2090 2620 3150 3680 4210

INSTALLATION DRAWINGS LINEAR CONFIGURATION 69 QUINTA PRO LINEAR CONFIGURATION, MOUNTED ON A FREE-STANDING FRAME TWO TO EIGHT BOILERS QUINTA PRO 530 231 500 284 500 3230 3150 555 30 500 100 A 1306 1576 X Y B 270 OV 1590 1590 T003419-A KEY or 125/DIN 2631 (8 holes) B System return; connection DN 100 or 125/DIN 2631 (8 holes) X Y Low loss header Distance to system return Gas supply connection DN 50 or 65/DIN 2633 (4 holes) concentric connection DIMENSIONS (MM) 2 4 8 Width mm 1170 1640 2170 2700 3230 3760 4290

500 QUINTA PRO BACK-TO-BACK MOUNTED OR FREE-STANDING FRAME CONFIGURATION (RG) THREE TO TEN BOILERS QUINTA PRO 530 200 500 2620 1055 30 500 100 A 1308 1576 B X Y OV 2650 325 125 KEY B or 125/DIN 2631 (8 holes) System return; connection DN 100 or 125/DIN 2631 (8 holes) X Y Distance to system return Low loss header Gas supply connection DN 50 or 65/DIN 2633 (4 holes) concentric connection DIMENSIONS (MM) 2 4 8 Width mm N/a 1030 1030 1560 1560 2090 2090 2620 2620

INSTALLATION DRAWINGS LINEAR CONFIGURATION 71 STRUCTURE OF QUINTA ACE 160 CASCADE SYSTEMS Complete cascade options are available for the Quinta Ace 160 with both insulated and non-insulated versions. Two to eight Quinta Ace 160 boilers in a linear QUINTA ACE 160 602 602 600 30 5090 5010 676 226 2003.5 630 630 630 630 630 630 630 630 325 125 5040 WALL-MOUNTED DIMENSIONS (MM) 2 4 8 Width mm 1230 1860 2490 3120 3750 4380 5010 FREE-STANDING DIMENSIONS (MM) 2 4 8 Width mm 1310 1940 2570 3200 3830 4460 5090

STRUCTURE OF QUINTA ACE 160 CASCADE SYSTEMS Complete cascade options are available for the Quinta Ace 160 with both insulated and non-insulated versions. Three to eight Quinta Ace 160 boilers in a back-to-back QUINTA ACE 160 630 340 602 2570 2490 30 600 1278 676 226 2003.5 630 630 2520 630 630 325 125 DIMENSIONS (MM) 2 4 8 Width mm N/a 1310 1310 1940 1940 2570 2570

80 mm 30 mm INSTALLATION AND CONFIGURATION 73 MULTIPLE OUTPUT QUINTA BOILER CASCADES Please contact your local sales manager for further information. Contact details are available via the website remeha.co.uk QUINTA BOILER CASCADES 80 mm 500 mm 600 mm 600 mm 55 mm 15 mm 1603.5mm ±5 mm Quinta Pro Quinta Ace Quinta Ace 1924mm ±5 mm Note: Please take into account boiler and component weights.

BESPOKE RIG SYSTEMS We provide bespoke rig system service to support consultants in overcoming plant room limitations and tight deadlines. These rigs remeha.co.uk BESPOKE RIG SYSTEMS