Room thermostats for fan-coils, 3 speeds + automatic

Similar documents
CH130ARR-CH130ARFR. Room thermostats for fan-coils, 3 speeds + automatic KIT THERMOSTAT ACTUATOR FAN CONNECTION COLOUR CODE CODE CODE SPEED TYPE

N L L1 C NC 230V MULTI-ZONE WIRELESS CLIMATE CONTROL SYSTEM CH175

RADIO WAVE WEEKLY PROGRAMMABLE THERMOSTAT CH150RF

Installer and User Manual. BeSMART. Thermostat WiFi Box and boiler RF receiver. Installer and User Manual ESC MODE SET PROG RESET

INTELLICOMFORT CH180WIFI TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION FOR REMOTE CONTROL

Intellicomfort CH140GSM

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Table 1. Serie of Digital Room Thermostats.

Easy-Stat. Wireless Programmable Room Thermostat Pt No

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

OPERATING INSTRUCTIONS

Programmable Towel Radiator Manual

Installation & Operation Instructions

Self-learning Room Temperature Controller

Sensor Control Panel

Wireless room thermostat with LCD

Installer Manual KNX Touchscreen Thermostat

T-32-TS Touchscreen Thermostat. Installation Manual

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

T5000 LCD Digital Fan Coil Thermostat

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

T6865 Series Large LCD Digital Thermostat 24 VAC 2-pipe fan coil control

TIREE FAN COIL CONTROLLER - T6580

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Operating Functions Temperature Parameters

Installation Manual. Zoning Kit

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

RM2S 2 module housing (sequence and phase-failure/asymmetry voltages)

ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Electronic thermostat for heating system

TEC210x-2 Series Networked Thermostats

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

Installation Instructions

RVL470. Heating Controller. Use. Functions. Series B

108A OTP1800. Grid Support. General Description

TEC2100 Series Networked Thermostats

Installation, Start-Up, and Operating Instructions

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

T6580 FAN COIL CONTROLLER

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

Emerson Blue Easy Set 1H/1C

OWNER S MANUAL. Part Number P CONTENTS

SMART THERMOSTAT WITH HOT WATER CONTROL

Installation Settings Guide

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

Climatouch /CT03TS/217S31 Programmable Universal Touch Screen thermostat

Room thermostat with 24-hour time switch and large LCD

5.5. Other configuration parameters EXCEPTION CODES AUTO DIAGNOSTICS Zoning box control board

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

The Book of AERMEC NRL Sequence of Operation

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

Installation & Operation Instructions

Installation Instructions

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Siemens room thermostats. For maximal comfort and energy efficiency

Installation Instructions

Regulation EASY CLIMA VERSION 1.6 TECHNICAL MANUAL

ETO 2 - Controller for ice and snow melting

Semi flush-mount room thermostats

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

GreenCon On/Off Room Thermostat

Self-learning Room Temperature Controller

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

IP65 High Bay Dual Sense Sensor

Room thermostat with Auto Timer, Option External Input

INTRODUCTION / TABLE OF CONTENTS

ETN1000/MIGA - Operating manual

Software Version 2.01 LEVEL MONITOR MODEL 220

Room thermostats with LCD RDD100..

Electronic timeswitch

Room Temperature Controllers

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

DC200 Digital Dispenser Operating Manual

Wave Series. Installation and User Guide. PE950 Hand-Held Remote Transceiver PE650 Panel-Mounted Transceiver

NEW. SkyStar SkyStar ECM. Cassette Fan Coil Units. consumption ECM motors. Low energy. Air Conditioning ENVIRONMENTAL COMFORT

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS

Heating and D.h.w. Controller RVL482 Basic Documentation

SCHMIDT LED Measured Value Display MD Instructions for Use

Installation Settings Guide

Fire / CO Alarm Interface

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

T500 Series Non-Programmable Thermostats

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

ECL Comfort V a.c. and 24 V a.c.

Installation & Operating Instructions

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

The ECL Comfort 110 is a universal 1-circuit controller for use in district heating substations and district heating systems as well as boilerbased

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS

Transcription:

CH130ARR-CH130ARFR Room thermostats for fan-coils, 3 speeds + automatic CH130A model is a fan-coil 4- or 2-pipe thermostat that allows you to control the ambient temperature both in the heating and cooling modes. Is able to drive one or two valves and also control a 3-speed fan-coil motor, either in manual or automatic CH130ARR has a separately activation unit with two-wire connection, while the CH130ARFR model has the separately activation unit with which communicates via radio frequency (wireless). 135 21 Dimensions (mm) 83 KIT COMPOSITION TABLE KIT CODE THERMOSTAT CODE ACTUATOR CODE FAN SPEED CONNECTION TYPE CH130ARR CH130AR CH172D manual + auto 2 wires CH130ARFR CH130ARF CH172DRF manual + auto wireless 44

CH130ARR KIT WITH REMOTE RELAY MADE UP OF: CH130AR THERMOSTAT + CH172D ACTUATOR 2 WIRES Mounting Temperature regulation range Body admissible temperature Power supply N relay Power supply Protection degree CH130AR wall mounting 2 40 C 45 C actuator CH172D - - IP20 CH172D 6-module DIN rail 45 C 230V-50Hz 5 5(3)A 250Vac IP00 CH172DS* 6-module DIN rail 45 C 230V-50Hz 5 5(3)A 250Vac IP00 *CH172DS is used to control more fan-coils. C CH130ARFR RADIO FREQUENCY KIT MADE UP OF: CH130ARF THERMOSTAT + CH172DRF ACTUATOR WIRELESS Mounting Temperature regulation range Body admissible temperature Power supply N relay Power supply Protection degree CH130ARF wall mounting 2 40 C 45 C 2 batteries AA 1,5V - - IP20 CH172DRF* 6-module DIN rail 45 C 230V-50Hz 5 5(3)A 250Vac IP00 *To control more fan-coils, always use CH172DRF actuator. 45

CH130ARR ELECTRICAL FEATURES Power supply from a remote actuator. Remote actuator with 5 output relays, voltage 250 Vac. Contacts rating 5(3)A. 4-TUBE INSTALLATION 2-wire connection hot water cold water thermostat CH130AR remote actuator CH172D 2-TUBE INSTALLATION 2-wire connection hot cold water thermostat CH130AR remote actuator CH172D 1 2 3 4 1 2 3 4 INPUT CONFIGURATION ON-OFF ESTATE INVERNO ingresso comandato con 24 Vcc ON-OFF SUMMER / WINTER supplied with 24 Vdc sonde di ripresa comando automatico ESTATE INVERNO contatto finestra/termostato di minima contatto invertito finestra/termostato di minima rerun probes SUMMER-WINTER automatic control minimum window/thermostat contact reverse contact (minimum window/ thermostat ) CH130ARFR ELECTRICAL FEATURES Power supply from 2 AA type batteries of 1,5V. Remote actuator with 5 output relays, voltage 250 Vac. Contacts rating 5(3)A. 4-TUBE INSTALLATION hot water cold water thermostat CH130RF remote actuator CH172DRF 46

2-TUBE INSTALLATION hot water cold water thermostat CH130RF remote actuator CH172DRF INPUT CONFIGURATION 1 2 3 4 1 2 3 4 ON-OFF ESTATE INVERNO ingresso comandato con 24 Vcc ON-OFF SUMMER / WINTER supplied with 24 Vdc sonde di ripresa comando automatico ESTATE INVERNO contatto finestra/termostato di minima contatto invertito finestra/termostato di minima rerun probes SUMMER-WINTER automatic control minimum window/thermostat contact reverse contact (minimum window/ thermostat ) HOMOLOGATION AND STANDARDS Complies with EN 60730-2-9 standards ErP: ErP Class IV; 2% (Reg. EU 811/2013-813/2013) C INSTALLATION The thermostat is supplied complete with a base suitable for mounting on the wall, as well in rectangular or round built-in 3-seat boxes. MOUNTING HOLES, mm 60 83,5 47

OPERATION CH130ARR is supplied from the actuator and is able to drive two valves and also control a 3-speed fan-coil motor. CH130ARFR is supplied with two AA batteries of 1,5V and is able to drive two valves and also control a 3-speed fan-coil motor by means of CH172DRF actuator. The wide display shows the measured temperature, fan speed, the running program and the selected season. The settings and data are stored in a permanent (nonvolatile) memory capable of keeping them even in the absence of or when the batteries are not inserted (according to the model). SUMMER/WINTER SELECTION To switch from the Winter operation (i.e. heating system) to the Summer operation (i.e. cooling system), and vice versa, press the 1+2 button combination. The selected operation mode will be indicated on the display by the Winter or Summer icons. BUTTONS COMBINATIONS 1 fan speed increase button, at the maximum prescribed speed is configured the AUTO operating 2 fan speed decrease button, exits the AUTO mode and decreases the fan speed. 1+2 SUMMER/WINTER switch. 3 temperature value increase button for the selected program. 2+4 Celsius/Fahrenheit switch. 3+4 COMFORT/ECONOMY switch. 4 temperature value decrease button for the selected program. 5 thermostat reset button. VISUALIZATION (SIGNALS) measured temperature COMFORT symbol ECONOMY symbol SUMMER symbol WINTER symbol fan speed symbol 1 2 3 4 5 OPERATING MODES CH130... thermostats have 3 different operating modes: With the COMFORT operating mode, the thermostat regulates the heating or cooling installation operation in order to always keep the same prescribed comfort temperature. With the ECONOMY operating mode, the thermostat regulates the heating or cooling installation operation in order to always keep the same prescribed economy temperature. (OFF) function can be achieved by setting the fan speed to zero. In this case, the thermostat does not perform the regulation. The system will switch OFF completely and on display will appear the message OFF. FAN SPEED SELECTION MANUAL: fan speed can be set manually to free fixed levels (minimum, medium, maximum). AUTO: if the speed is set in Auto, the thermostat sets automatically the appropriate speed according to the difference between the set-point and the ambient temperature. CH130A thermostat has available a TECHNICAL MENU for adapting to different system types. TECHNICAL MENU SYSTEM TYPE 2-tube system: the thermostat will drive only the valve (ON/OFF type) used for heating both during the heating and the cooling; in fact, the valve will control both hot water and cold water. 4-tube system: the thermostat will drive one valve (ON/OFF type) used for heating, plus one additional valve (ON/OFF type) used for cooling, based on the needs of the environment. 48

EXTERNAL PROBE RESUMPTION: instead of the probe incorporated into the thermostat, an external probe can be used to read the ambient temperature and carry out heat regulation. Typically, this probe will be positioned under the fan-coil where air is sucked. CHANGEOVER: the external temperature probe can be placed on the fan-coil delivery tube of a 2-tube system to perform automatic changeover between the Summer operation and the Winter operation. MINIMUM WINDOW/THERMOSTAT CONTACT: when the contact is open, the thermostat will carry out heat regulation; when it is closed, the heat regulation will not be carried out. INVERTED MINIMUM WINDOW/THERMOSTAT CONTACT: the window contact will operate with an inverted logic with respect to the statements made in previous step 3. NONE: the external probe will not be controlled by the thermostat. DISPLAY VISUALIZATION AMBIENT TEMPERATURE: the ambient temperature will be shown on the display. SET-POINT: the current set point will be shown on the display. CENTRAL INPUT CONFIGURATION ON/OFF: in the event that several thermostats have been installed, you may decide either to drive all of them in the normal operation condition (ON) or taking advantage of the OFF function by controlling them through a central point. The thermostat will be configured to OFF when the is powered with 24 V (d.c. with no polarity obligation or a.c.); on the contrary, it will remain active when the is free from voltage. SUMMER/WINTER: as in the previous case, the thermostat will be configured to Summer mode when the is powered with 24 V; on the contrary, it will remain active in the Winter mode when the is free from voltage. NONE: the thermostat will not carry out any operation, whatever the status. SUMMER VALVE TYPE NORMALLY OPEN: in this case, the water flow is normally open and will be closed when the valve is supplied. NORMALLY CLOSED: when the valve is energized, it will open the water flow. WINTER VALVE TYPE NORMALLY OPEN: in this case, the water flow is normally open and will be closed when the valve is supplied. NORMALLY CLOSED: when the valve is energized, it will open the water flow. AMBIENT TEMPERATURE CORRECTION It can be adjusted from 4.0 to 4.0 C. This parameter is used to correct the acquired ambient temperature. In fact, in some installations, the ambient temperature reading may not be satisfying, due to the probe location (i.e. internal or resumption). With this parameter, a constant value upon reading can be added to or subtracted from. C WINTER LOWER LIMIT SET-POINT TEMPERATURE It can be adjusted from 2.0 to 40.0 C. It represents the lower limit for all the set-points (Comfort and Economy) in the heating WINTER UPPER LIMIT SET-POINT TEMPERATURE It can be adjusted from 2.0 to 40.0 C. It represents the upper limit for all the set-points (Comfort and Economy) in the heating SUMMER LOWER LIMIT SET-POINT TEMPERATURE It can be adjusted from 2.0 to 40.0 C. It represents the lower limit for all the set-points (Comfort and Economy) in the cooling SUMMER UPPER LIMIT SET-POINT TEMPERATURE It can be adjusted from 2.0 to 40.0 C. It represents the upper limit for all the set-points (Comfort and Economy) in the cooling CHANGEOVER LOWER THRESHOLD It can be adjusted from 0 to 24 C. It defines the changeover function lower threshold. Below this temperature, the thermostat will be set to the cooling CHANGEOVER UPPER THRESHOLD It can be adjusted from 26 to 48 C. It defines the changeover function upper threshold. Above this temperature, the thermostat will be set to the heating 49

A CH130ARR can control up to 5 fan-coil units simultaneously, using only two cables for connecting to the actuators. One of these actuators must be a CH172D, while others, maximum four, will be CH172DS. A CH130ARFR can control an unlimited number of actuators provided that they are located within reception range of 30 meters. CONNECTION EXAMPLE BETWEEN CH130AR+CH172D AND 1 FAN-COIL CONNECTION EXAMPLE BETWEEN CH130AR+CH172D+CH172DS AND FEW FAN-COILS (FROM 2 TO 5) CONNECTION EXAMPLE BETWEEN CH130ARF+CH172DRF AND 4 FAN-COILS FEATURES Auxiliary for minimum window and/or thermostat contact using an external probe. Screwed terminals. double insulation. Dimensions 135 X 83 X 21 mm. 50