FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER TR

Similar documents
Rozp.UE2015/ kw kw

Forward-looking and energy effi cient Biomass heating

HDG K SERIES. Wood pellet boiler. The perfect alternative to fossil fuels. Receive up to

Biomass Pellet Boilers

Combined boiler. for solid fuel and pellets

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

English. Heating with logs & wood pellets 20-40

Rozp. UE 2015/

Heating with log wood

PZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

WOOD CHIP HEATING HPK-RA

Aquaflam Wood boiler stoves and fireplace inserts

WOOD CHIP HEATING HPK-RA

Boiler Technical Specifications (2013)

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

USER MANUAL 9kW LILLY PELLET STOVE

Your guide to. Biomass Heating Systems

LOG BURNING BOILERS. Zeroridge Biomass Ed 17A

TECHNICAL AND OPERATIONAL DOCUMENTATION

Masterflamme Convection Wood Stoves Perfect combustion with unique design

Log fired heating system

Eco Angus Wood Pellet Boilers

HERZ ECO-Line Heating with logs or wood pellets

ETA PE-K. The pellet boiler with technology that's built to last, for larger heating needs. 35 to 90 kw. A passion for perfection.

MANUAL. Page 1/44

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

JÄSPI Solid Fuel Boiler

Efficient CHP-plant 150 kw

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL MANUAL. CENTROMETAL d.o.o. Glavna Macinec Croatia tel: ; fax :

product catalog 2014 The most awarded central heating boilers in Poland

High quality boiler stoves and fireplace inserts

it warms us up! PRICE LIST

Installation & Manual. Model T-25

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

Pellet boiler Electronic Modulation Automatic Cleaning Grinder system Easy Installation 4 power levels: 10, 16, 25, 43 kw

STILE BEAUTY AND TECHNOLOGY

Heating with wood chips & pellets

Heating with wood chips

Max-3 Steel Shell Boiler

Heating with wood pellets kw

USE AND MAINTENANCE. Cm Pelet-set TECHNICAL INSTRUCTIONS. (14-35 kw) For boilers: EKO-CK P (EKO-CK 20-40) EKO-CKB P (EKO-CKB 20-40)

Smart Heating Technology Ltd. U Statku 653/24, Ostrava-Bartovice Czech Republic

Pioneers of heating with biomasses

Wood Chip and Pellet Boilers. Turbomat TM 500.

Easyfire Standalone biomass pellet boiler

WOOD GASIFYING BOILER ATTACK DPX STANDARD / PROFI / LAMBDA INSTRUCTIONS FOR USE WWW. ATTACK.SK

Biomass. Biomass solid fuel boiler range

Turbomat. Wood Chip and Pellet Boilers. Turbomat TM 150/200/250 TM 300/320/400/500 STURDY CONSTRUCTION INDUSTRIAL MODEL.

Masterflamme Convection Wood Stove

Importance of a Draught Regulator

Cm Pelet-set (60-90 kw)

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens

English. Heating with logs & wood pellets 20-40

Installation, operation and care Firewood boiler Vedolux 40 UB

Cm Pelet-set TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT. (14-35 kw) For boilers: EKO-CKB P (EKO-CKB 20-40)

PE1 Pellet. PE1 Pellet. Pellet boiler - Canada. PE1 Pellet APPROVED FOR EPA 2020 EMISSION LIMITS.

Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

USE AND MAINTENANCE. Cm Pelet-set (60-90 kw) TECHNICAL INSTRUCTIONS

EWI-THERM Hot-Air Heating Systems Types Prestige-SE, Optimal-E and H-F-L

Your home heating since 1888

EKO Line Pellet Boiler Wood Pellet Storage Solutions And Pellet Dosage Systems

AIREX 2S WOOD PYROLYSIS SUCKING FAN

With its particular heat retencion capacity, cast iron is the perfect

Turbomat. Wood Chip and Pellet Boilers. Turbomat TM 150/200/250 TM 300/320/400/500 STURDY CONSTRUCTION INDUSTRIAL MODEL.

THE WOOD GASIFYING BOILER ATTACK SLX, DPX, DP STANDARD / PROFI / LAMBDA TOUCH / COMBI PELLET

tççç= ÜÉ~íáåÖ çéíáçåë

Fully-automatic Wood Pellet central heating

TopGas Wall Hung Condensing Gas Boiler

Multi Energy Boilers. Duo 1 & 2 Triplex 1000 & 3000 Biotriplex. Oil Gas LPG Wood Briquettes Electricity Solar thermal Solar photovoltaics

natural warmth of the house A compact boiler designed to combust ecological fuel- pellet ORLIGNO 500 Compliant with EN norm

modern heating devices

Heating with pellets kw

Operating manual. Wood pellet boiler. PL M 15 and PL M 25

GAS AND PELLET BURNERS

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Solid biofuel solutions

- 12, , TECHNICAL INSTRUCTIONS

R A N G E C O N C E P T

Leading European manufacturer of fireplace stoves and fireplace inserts

TECHNICAL MANUAL BIOTEC 25 AND BIOTEC 40

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

KWB CLASSICFIRE Log-wood and pellet heating system 18/28 kw

ISO 9001 TUV CERT CE

Waste/Multi Oil Boilers from Flexiheat

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE

Rapid. Suspended Warm Air Heater. Caring for the environment!

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

INSTRUCTION MANUAL & SERVICE MANUAL ORLAN 96 SUPER ORLAN 130 SUPER

MULBERRY STOVES. cast a warm eye on life

Cassette inserts and fireplace doors

PELLET BURNER PV 350

Technical Datasheet. P4 Pellet Boiler Models 8/15, 20/25, 32/38, 48/60. Benefits at a Glance:

1 VICTRIX ZEUS Superior kw I features

Transcription:

FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER TR STADLER TR firewood hot water central heating boilers provide comfortable and energy saving heating. Such heating is enabled with integration of the new innovative technology in the field of control and modern production technology. s are constructed for burning all types of wood and reach efficiencies of over 91%. Constant growth of fossil fuel prices and the increased care for the environment make this boiler even more important. By using different types of wood, even of different humidity, these boilers allow you to reach perfect combustion conditions. Emitted flue gases are harmless to the natural balance. You should load the boiler with ½ m long firewood as close together as possible, thus reaching uniform fuel structure and stable combustion conditions. Single load should be enough for several hours of operation. Fireplace volume equals to 150 l and can be loaded with up to 50kg of hardwood logs. Connection to the power supply is very simple, as the boiler includes already prepared wiring with plug equipped cables. By purchasing our boiler, you meet all of the requirements to obtain your government's subsidy. Construction of the boiler incorporated the modern degassing combustion technology. The flame is vertically directed through the burner nozzle with the help of the controlled injection of the primary and secondary air. When the flame enters the combustion chamber, it swirls and in touch with the red-hot combustion chamber causes the remaining not-combusted wood gases to burn at temperatures of approx. 1000 C. The control regulates the operation of the primary and secondary air step motors, thus supplying the combustion process with regulated quantities of air which enable the best combustion. The large panel shielded loading place protects the boiler from accumulation of tar and ensures long service life of the boiler. s can be loaded with firewood of up to 56 cm in length. The burner nozzle is made of chrome alloy which also significantly prolongs the service life of the boiler. 2 The boiler is included in the German BafA-List and therefore entitled to incentives. The fireproof clay combustion chamber is upgraded with the bottom made of high-temperature resistant concrete which guarantees complete combustion of wood gases. s are equipped with the Lambda probe, temperature sensor and continuously controlled electric motor of the fan. WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

Technically perfected turbulator system enables flue gases to swirl and better efficiency of the boiler. The feeding mechanism allows good cleaning of the pipe register. With the help of the active combustion control equipped with the Lambda probe we provide products with many advantages: Simple and clear control, The lowest fireplace load, Longer service life of the boiler, Module control allows longer combustion phase, The best efficiency with the lowest emission values, Emitted flue gases are harmless to the environment, Constant control of the combustion process, Continuous fan control, Optional programmed ignition. The control allows simple control of the boiler. Fuel ignition can also be activated via your cell phone. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of 0.40. Characteristics Unit TR 15 TR 20 TR 25 TR 30 TR 35 Nominal heat value kw 15 20 25 30 35 Lowest boiler power kw 8 15 15 15 20 efficiency at nominal power % 90,01-91 90,01-92 90,01-92 90,501-92 90,01-92 Combustion efficiency % 93,1-95,5 93,1-95,5 93,1-95,5 93,1-95,5 93,1-95,5 Container volume l 150 150 150 150 150 Loading door width and height mm 430 x 400 430 x 400 430 x 400 430 x 400 430 x 400 water quantity l 193 193 193 193 183 Chimney connection mm 150 150 150 150 150 Permissible operating pressure bar 3 3 3 3 3 Required chimney draft Pa 13 13 13 13 13 Max. flow temperature C 95 95 95 95 95 weight kg 735 735 735 735 760 Recommended accumulator size l 1800 1800 1800 2000 2000 height mm 1480 1480 1480 1480 1480 width mm 695 695 695 695 695 depth mm 1200 1200 1200 1200 1200 Height of the chimney connection mm 1010 1010 1010 1010 1010 Delivery tube R 5/4 5/4 5/4 5/4 5/4 Return tube R 5/4 5/4 5/4 5/4 5/4 Supply discharge fitting R 3/4 3/4 3/4 3/4 3/4 Thermal protection device fitting R 3/4 3/4 3/4 3/4 3/4 Electrical connection 230 V +10/-15 %/50 Hz 160 W for operation; 400 W for ignition WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 3

FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER LT Due to their wood gas combustion technology, Stadler LT firewood hot water central heating boilers enable energy saving heating. s are constructed for burning all types of wood and reach efficiencies of over 90%. They are completely made in Slovenia, thus showing high level of expertise. Development of the product brought such improvement that our company was granted with the national patent by the Slovenian Intellectual Property Office. These hot water boilers are constructed for burning of 56 cm, or 33 cm long firewood. You should load the boiler with firewood as close together as possible, thus reaching uniform fuel structure and stable combustion conditions. Single load should be enough for several hours of operation. Fireplace volume equals to 125 dm3 and can be loaded with approx. 35 kg of firewood. The container should be loaded with firewood to its top limit, while taking care not to load the firewood too close to each other as this could cause jamming. Modern control with lambda probe enables you to burn different types of wood and to reach ideal combustion conditions with flue gases which are harmless to the natural balance. These boilers are equipped with modern fireplaces with hot combustion chambers made of temperature resistant ceramics. The hot combustion chamber allows swirling combustion of wood gases resulting in the combustion of all combustible substances in flue gases. Temperatures in the combustion chamber can reach over 1000 C, thus creating perfect combustion conditions. s can be installed into systems equipped with hot water reservoirs and room temperature control. The control regulates circulating pumps and motor driven three-way valves, thus achieving balanced consumption of the Characteristics Nominal heat value Unit kw LT 20 15-20 LT 25 / LT 30 25-30 reservoir's temperature layered water and longer heating time. Lowest boiler power kw 7 15 efficiency at nominal power % 90,1-91 90,3-91,2 Combustion efficiency % 92,1-93,1 93,3-94,5 Firewood container volume l 125 125 Loading door width and height mm 400 x 440 400 x 440 water quantity l 117 110 Permissible operating pressure bar 3,0 3,0 Max. flow temperature C 95 95 Upper chimney connection mm 150 150 Required chimney draft Pa 15 20 weight kg 554 559 Recommended hot water reservoir size l 1500 2000 height mm 1385 1385 width mm 660 660 depth mm 1200 1200 Height of the chimney connection mm 1420 1420 Delivery tube " 5/4 5/4 Return tube " 5/4 5/4 Water supply fitting " 1/2 1/2 Thermal protection device valve fitting " 3/4 3/4 Electrical connection 230 V +10/-15%/50Hz 160 W for operation; 400 W for ignition Our boiler is in compliance with all currently valid provisions on safety and construction design (e.g. DIN 4751 B1.1, DIN 4702, EN 303-5). It is tested for pressure and water tightness and factory equipped with a thermal protection device, thus enabling the installation in closed heating systems. Permissible operating pressure of the boiler equals to 3 bars. All integral parts are made of tested materials of suitable quality and thickness. s are also equipped with the CE 0036 marking. Flue gas sensor 4 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

Construction of the boiler is patent protected, as its development included several innovations which significantly contributed to the improvement of the combustion processes. Our family of products equipped with the Lambda probe is one of the best in EU. CONTROL WITH LAMBDA PROBE The combustion process is regulated with a modern control via lambda probe and other temperature sensors. All data is promptly checked by the central control microprocessor which also performs corrective measures for the improvement of the combustion process. Control regulates the continuous control of the fan and the primary and secondary combustion air supply motor flap. The extremely efficient control also regulates the external heating system structures and allows control of operation via your cell phone. If the boiler is loaded with firewood, you can also start it with your cell phone. This novelty is appropriate especially when you are away from home longer than expected, or simply to make your home warm and comfortable at the time of your arrival. 1 2 3 4 5 6 7 8 9 10 11 1 - USB - port for PC connection 2 - Graphical display 3 - Button (exit/reset) 4 - Button for the cleaning of the boiler, emissions measurement and safety thermostat test 5 - Button (down/reduction) 6 - Button (admission to menu/selection confirmation) 7 - Button (help) 8 - Button (forward/slope) 9 - Button (boiler commissioning /boiler charging) 10 - (Thermal fuse) 11 - Button (control ON and OFF) The combustion of firewood can be programmed via the ignition electrode. Preparation of firewood for the programmed ignition is simple and does not include special procedures. Fuel ignition can also be activated via your cell phone. Technically perfected turbulator system enables flue gases to swirl and better efficiency of the boiler. The feeding mechanism enables good cleaning of the pipe register. The combustion chamber made of high-temperature resistant ceramic ensures perfect combustion of wood gases. The reliable and robust fan equipped motor is continuously controlled and helps the fine-tuned control of the combustion process. Motor is protected with sheet metal cover which prevents all kinds of damage. The wiring of the boiler is made of temperature resistant cables and very clear. Power connection of the boiler can simply be performed at the terminal assembly on the external side of the boiler. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of 0.40. The measurement certificate classifies the boiler on the list of subsidized boilers. WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 5

FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER GT STADLER GT boilers belong to a new generation of firewood hot water heating boilers. With their wood gasification technology they enable modern and energy saving heating. They are constructed to burn all types of firewood of up to 54 cm or 33cm in length. Their combustion efficiency reaches over 90%. themselfs are designed and produced in Slovenia. By naming the product range STADLER we wished to show that the production is still active and adapts to new combustion conditions and techniques. These boilers provide stable combustion processes enabled by the inovative construction and lambda probe. They achieve excellent combustion parameters which are characteristic for wood gasification boilers. Quality production, controlled combustion process and high efficiency of these boilers beat the competition of the lower priced boilers by far. By using different types of wood, it is possible to achieve good combustion conditions in the boiler. Firewood burns in the lower part, whilst the supplied primary air leads the flame and wood gases downwards into the combustion chamber. When flue gases come through the burner nozzle, they are blown with controlled supply of secondary air. Flue gases mixed with the flame and fresh air swirl in the combustion chamber, and in touch with the red-hot fireproof clay, burn with extreme temperatures. The control regulates the combustion process via lambda probe and the temperature sensor in the chimney and sensors installed in the boiler and the accumulator. It also regulates the continuous control of the fan and the primary and secondary combustion air supply motor flap. Controlled supply of the combustion air enables low values of emmissions in flue gases which are significantly lower than the law regulated ones. s are equipped with an insulated hot combustion chamber made of fireproof clay which quickly reaches high temperatures and enables good combustion of wood gases. The efficiency boilers reache over 90% which points out the top-class echievement. The hot combustion chamber enables the boiler to reach the optimal combustion process in only minutes. These boilers must be installed into systems equipped with hot water accumulators. We recommend the use of the heating system control because this is the only way to preserve different water layers in the hot water accumulator. Our boilers are in compliance with all currently valid provisions on safety and construction design (e.g. DIN 4751 B1.1, DIN 4702, etc.). They are tested for pressure and water tightness, factory equipped with a thermal protection device and can be installed in closed heating systems. The permissible operating pressure of boilers equals to 3 bars. We recommend the use of firewood with humidity between 15 and 25% which is achieved by drying it outdoors for 2 years. You should load the boiler with firewood as close together as possible, thus reaching uniform fuel structure and stable combustion conditions. Single load should be enough for several hours of operation. The volume of the fireplace is 105 dm3 and can be loaded with approx. 30 kg of firewood. You should load the container with firewood to the top of the doors, while taking care not to load them too close to each other as this could cause jamming. The boiler is included in the German BafA-List and therefore entitled to incentives. Characteristics Unit GT 20 GT 25 GT 30 Nominal heat value kw 20 25 30 Lowest boiler power kw 10 15 kw 10 12 15 efficiency at nominal power % 91 91 91 efficiency at nominal power % 93 93 93 Container volume l 105 105 102 Loading door width and height mm 400 x 350 water quantity mm 132 125 125 Chimney connection diameter mm 150 150 150 Permissible operating pressure bar 3 3 3 Required chimney draft Pa 13 13 13 Max. flow temperature C 95 95 95 weight kg 585 600 600 Recommended a-ccumulator size l 1500 1500 1800 height mm 1356 1356 1356 width mm 638 638 638 depth mm 1360 1360 1360 The depth of the boiler with open doors mm 1760 1760 1760 Depth of the loading area mm 555 555 555 Height of the chimney connection mm 1225 1225 1225 Delivery tube R" 5/4 5/4 5/4 Return tube R" 5/4 5/4 5/4 Supply discharge fitting R" 1/2 1/2 1/2 Thermal protection device fitting R" 3/4 3/4 3/4 Electrical connection 230 V +10/-15%/50Hz 80 W for operation; 200 W for ignition 6 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

WOOD PELLET HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER PELET STAR Stadler PELET STAR hot water central heating boilers belong to a new generation of wood pellet boilers. They were designed by our company in cooperation with the Swedish company Ariterm. The BeQuem burner enabled the development of a completely automatic wood pellet boiler which guarantees reliable and safe operation with minimum cleaning and maintenance interventions. s are produced with the modern sheet metal treatment technique. Construction concepts provided the boiler with a touch of modern design, while respecting the ergonomic demands for the operation of the boiler. Construction of the boiler is produced in accordance with regulations DIN 4751 B1.1, DIN 4702, EN 303-5. s are equipped with the CE 0036 marking and can also be installed in smaller rooms to provide comfortable and energy saving heating. The side of the boiler is equipped with the weekly wood pellet silo, whilst the large ash chamber allows longer intervals between cleaning. Construction of boilers allows easy access to all internal surfaces and hence easier cleaning and maintenance. We recommend you to install your central heating system with a hot water accumulator which allows optimum boiler operation with low energy consumption (low-energy constructions and transition periods). In case of bigger consumption, the hot water accumulator amortizes the current lower burner operation capacity. Special construction of the BeQuem wood pellet burner allows reliable operation and high level of safety. Wood pellet feeding is arranged with a double stoker system where the lower stoker feeds wood pellets into the lower part of the combustion chamber. With such wood pellet feeding the ash is pushed further and the combustion chamber automatically cleaned. Such feeding technique makes the burner appropriate even with wood pellets of weaker quality which can now often be found on the market. Fire safety is ensured with temperature sensors and the cell block. Ignition and control of the flame are controlled with a special sensor. Characteristics Unit PELET STAR Nominal heat value kw 20 40 Lowest boiler power kw 5 20 efficiency at nominal power % 90,1-91 90,3-91 Combustion efficiency % 91,9-92,4 90,9-91,3 Wood pellet container volume l 250 250 Cleaning door width and height mm 330 x 250 330 x 250 water quantity l 126 140 Permissible operating pressure bar 3,0 3 Max. flow temperature C 95 95 Upper chimney connection mm 130 130 Required chimney draft Pa 15 15 weight kg 280 290 Recommended hot water reservoir size l 750 1000 height mm 1430 1430 Width of the boiler including the wood pellet container mm 1020 1020 Depth of the boiler with the burner and the fan mm 1350 1350 Height of the chimney connection mm 1330 1330 Delivery tube 1 1 Return tube 1 1 Supply fitting 1/2 1/2 Electrical connection 230 V+10/-15 %/50Hz 80 W for operation; 200 W for ignition 1 2 3 4 5 6 7 8 9 10 Combustion chamber made of high resistant alloy guarantees good combustion of wood pellets. Wood pellets are transported into the combustion chamber from below. Newly arrived pellets push the ash from the chamber, thus making cleaning of the chamber's burner unnecessary in the period of one heating season. Burner cleaning is simple. Unscrew it and simply remove from the boiler. LEGEND 1. Cell block 2. Transverse stoker 3. Fuel supply 4. Ignition electrode 5. Primary air pipe 6. Ignition pipe 7. Transport mechanism 8. Fan 9. Feeding stoker 10. Combustion chamber with wood pellets WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 7

WOOD PELLET HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER C 28 With the help of new innovative technologies wood pellet heating boilers enable comfortable, energy saving, and environment friendly heating. Firewood heating boilers represented the basis for the construction of wood pellet heating boilers. These boilers were constructed in cooperation with the HDG company and conform to the strictest regulations prescribed for such products. This claim is confirmed with the TÜV certificate. The boiler was reconstructed to burn wood pellets and now, in compliance with the prescribed flue gas emissions, enables combustion of wood pellets with efficiency of over 90%. s are equipped with an additional function which gives them advantage over other similar products. In case you run out of wood pellets or electric power, boilers also allow to burn firewood. Reorganization of the boiler to burn firewood is simple. Simply cover the opening of the burner and connect the draft control. The Swedish made burner allows integration with solid fuel boilers so that they serve as heat exchangers. Except for the environment friendly flue gases the burner operates in similar way as the oil burner. Ignition, operation and deactivation are automatic. Wood pellet feeding is performed with an extremely energy saving stoker which takes the pellets from the silo and feeds them into the burner. The burner can easily be set via the display. Combustion is regulated via the control installed on the burner. Burner operates in two levels in accordance with energy requirements. ADVANTAGES OF WOOD PELLET BURNING DEVICES construction is adapted to burn wood pellets, Enabled firewood burning, Completely automatic operation, Combustion with optimal efficiency, Good control enables energy saving operation, is made of 8 mm sheet metal, Efficiency of over 90%, No problems related to fuel preparation, Wood pellet supply similar to fuel oil supply, Care for the environment. Characteristics Unit C 28 PELET PX 22 GP 20 Nominal heat value kw 25 Lowest boiler power kw 10 efficiency at nominal power % 90,12 water quantity l 70 Chimney connection mm 130 Permissible operating pressure bar 3 Required draft Pa 13 Max. flow temperature C 95 weight kg 370 Recommended accumulator size l 1000 height mm 1070 width mm 797 Width of the boiler including the burner mm 1090 depth mm 660 Height of the chimney connection mm 780 Delivery tube 1 Return tube 1 Supply discharge fitting 1/2 Thermal protection device fittings 1/2 Electric connection 230 V/50 Hz 8 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

WOOD PELLET HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER EKO PELET Stadler EKO PELET hot water central heating boilers were designed with combination of firewood boilers and Swedish made burners. In this way boilers with the BeQuem wood pellet burners became automated units for heating of living quarters. Unlike the use of fossil fuels, the use of local energy resources, such as wood pellets, is harmless to the environment and decreases heating costs. These wood pellet boilers are equipped with a control which allows completely automated operation of the boiler without constant regulation. They regulate the supply of pellets from the container and the combustion process. s are also equipped with a pellet ignition device and flame control. The burner activates automatically as soon as the sensor in the boiler detects fall of water temperature bellow the preset value, and deactivates as soon as this temperature is reached. The volume of the factory offered wood pellet container equals to 0.6 m3 which is enough for approx. 10 days of operation. Alternatively you can order a larger container with volume of 0,93 m3. Our company also offers elements for the construction of even larger wood pellet containers which can be assembled in your boiler room or the room next to it. These boilers can easily be rearranged into firewood heating boilers by unscrewing the flange screws, removing the burner and turning it into the position which does not interfere with the operation of the boiler. Then, you have to install the cover over the burner on the external side of the boiler. Fix the cover firmly and prevent the flue gases from escaping. Cleaning of the boiler is also very simple. Open the lower door and remove the ash collected in the drawer. From time to time it is also necessary to check if the combustion chamber is clean. In case you notice any slag residue, remove it adequately. We do not recommend you to disassemble the burner during cleaning, however if this is necessary please call our authorised repair service centre. After each rearrangement of the boiler for burning firewood, clean the fireplace of the boiler and the space under the grate. The construction of the burner is equipped with a display showing mode of operation and temperature. Under the display, there are some arrow keys which enable you to scroll along the simple menu. With the use of these keys you can set the operation of the burner or simply control its operation. Calculation of the required boiler power m 2 cm 0,30 Apartment x Living quarters x Heat loss size height coefficient Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of 0.40. In case of simpler heating systems we recommend you to install a special pump. This special pump with a three-way valve ensures that the boiler first reaches the temperature of 60 C and then only emits the excess energy into the system. During the cool down phase, the pump and the three-way valve ensure that the water temperature in the boiler does not fall below 55 C, thus preventing the formation of condensate. If the system includes a hot water accumulator, the three-way mixing valve allows the accumulator to be filled. With the use of the water accumulator, better operation can be achieved, especially during transition periods when temperatures are not too low. model Wood pellet boiler capacity kw Firewood boiler capacity kw / 860 = Required boiler power Electric connection 240 V 50 Hz Power consumption 240 V 50 Hz Efficiency EKO PELET 20 10-20 30 450 W 60 W 91,5 % EKO PELET 40 25-40 40 600 W 90 W 90,7 % WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 9

WOOD PELLET AND FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER EKO PELET Kompakt EKO pelet Kompakt wood pellet hot water heating boilers are equipped with wood pellet containers located above the boiler where the domestic water heater is generally installed. These boilers are appropriate for installation in smaller spaces where there is desire for comfortable and energy saving heating. s are produced left or right oriented. They can easily be rearranged into firewood heating boilers by unscrewing the flange screws connecting the burner and the boiler, removing the burner and turning it into the position which does not interfere with the operation of the boiler and its safe loading. Then, you have to install the cover over the burner on the external side of the boiler. Fix the cover firmly and prevent the flue gases from escaping. Fasten the line of the draft regulator to the primary air flap of the lower door. Remove the safety barrier and the rectifier from the boiler. After you finish the above procedure, the boiler is rearranged to use firewood. CHARACTERISTICS OF FIREWOOD BOILERS: Stadler EKO hot water central heating boilers are constructed to burn 33 cm long firewood (logs are to be loaded transversely) and 56 cm long firewood (logs are to be loaded longitudinally to the boiler). They are intended for operation in the 90/70 C mode. The new way of flue gas conduction improves combustion processes during the burning of firewood. Loading doors enable loading of large logs. Constructions of boilers are produced in accordance with regulations DIN 4751 B1.1, DIN 4702 and EN 303-5. s are also equipped with the CE 0036 marking. Chimney must be constructed in accordance with solid fuel boiler chimney manufacturer's tables and must ensure drafts as described in the table of the brochure related to individual boiler models. s are equipped with large fireplaces, therefore we recommend you to burn your wood pellets or firewood in a downwards direction, thus prolonging the combustion time of a single load. During the burning phase, the draft regulator must constantly be set above 70 C, thus preventing overcooling of the return water and formation of condensate in the fireplace. We also recommend the installation of one of the insufficient water return prevention systems. Easy access to all internal surfaces enables easy cleaning and maintenance. Burner position during firewood burning. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of 0.40. model Eko Pelet Kompakt Firewood power kw Wood pellet capacity kw Delivery tube R Pellet silo for Kompakt l Self-standing pellet silo for Eko Pelet l water quantity l Weight EKO s kg L B H-Eko Kompakt DIMENSIONS (mm) Hs-Eko Pelet D F G d 20 20-25 10 20 5/4 300 600 126 280 655 640 1735 1170 930 540 550 160 40 35-40 25-40 5/4 330 900 164 360 855 640 1735 1170 920 540 550 130 10 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

HOT WATER CENTRAL HEATING ACCUMULATORS MODEL: AT Hot water accumulators represent intermediate central heating elements and are used in modern heating systems. They are used for accumulation of the excess thermal energy produced by the boiler and for evenly regulated supply of energy to different consumers. Hot water accumulators are indispensable in systems with installed firewood, wood pellet, or wood chip heating boilers. Firewood heating boilers do not allow the complete control of power without significant interruption of the combustion process. Firewood combustion cycle brings excess thermal energy which consumers cannot use at that moment therefore it is conducted to the hot water accumulator. After the fuel has burnt and the heating elements cooled down, the automatic control takes care for transfer of hot water from the accumulator to heating elements. Our production programme includes hot water accumulators of various sizes: 500, 750, 1000, 1250, 1500, 1800, 2000, and 3000l. Accumulators are equipped with fittings for connection of heating circles, sensors and thermometers. The number of used fittings depends on the complexity of the planned heating system prescribed by the manufacturer at the time of sale of the product or by other professional subjects. Model / values Unit AT 500 AT 750 AT 1000 AT 1250 AT 1500 AT 1800 AT 2000 AT 3000 Volume l 520 780 1080 1300 1570 1830 2090 3050 D1+diameter including insulation mm 900 950 995 1150 1200 1300 1300 1500 D-diameter mm 700 750 795 950 990 1090 1090 1290 H - height mm 1665 1867 2168 2023 2225 2230 2380 2610 H angled height mm 1700 1910 2210 2070 2300 2290 2460 2690 Total weight kg 112 144 176 190 211 242 258 330 Permissible operating pressure bar 3 3 3 3 3 3 3 3 Max. operating temperature C 95 95 95 95 95 95 95 95 Take care that the angled height is not greater than the room height, as this would prevent the installation of the accumulator. D1 Our production programme includes several standard volume hot water accumulator types: AT AT B AT BI AT B2I AT B3I AT I AT 2I AT 3I AT 3I PB WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 11

FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER EKO in EKOs Stadler EKO heating boilers are constructed in accordance with new findings concerning wood combustion processes. Fireplaces are adapted for standard firewood lengths (33cm and 50cm). Construction of the fireplace also allows loading of somewhat longer logs. Permissible cutting length equals to +6cm. The above stated means, that it is possible to load the boiler with firewood of up to 40 cm and 56 cm in length. s EKO 12-25 are to be loaded with 33 cm long firewood, whilst boilers EKO 30-100 are to be loaded with 50 cm long firewood. s are designed for operation in the 90/70 C mode, whilst their return water preheating system improves the thermal load of the boiler. The new way of flue gas conduction improves combustion processes during firewood burning. Large loading doors allow easy loading of firewood into the fireplace which can be loaded with large quantities of firewood, therefore we recommend you to burn your firewood in a downwards direction, thus prolonging the combustion time of a single load. The heater temperature control is performed by setting the desired temperature on the control cabinet which represents an integral part of the boiler equipment. Equipment of EKO boilers also includes quality enamelled domestic water heaters. They are equipped with an Mg-anode which serves for enamel protection. s with EKOs marking (s - solo) are not equipped with hot water heaters, but can be additionally bought and installed. Construction of boilers is made with 3D-designing in accordance with all regulations related to boiler construction like DIN 4751 B1.1; DIN 4702, EN 303-5. s are equipped with the CE 0036 marking. and heater are tested for pressure and water tightness. The permissible operating pressure of the boiler equals to 3 bars. For the purpose of achieving high product quality, all integral parts of the boiler are made of quality materials. s are also factory equipped with thermal protection devices. Chimney must be constructed in accordance with solid fuel boiler chimney manufacturer's tables and must enable drafts as described in the table of the brochure related to individual boiler models. s are equipped with large fireplaces, therefore we recommend you to burn your fuel in a downwards direction. During the burning phase, the draft regulator must constantly be set above 70 C, thus preventing overcooling of the return water and formation of condensate in the fireplace. We also recommend the installation of one of the insufficient water return prevention systems. Easy access to all internal surfaces allows easy cleaning and maintenance. SCOPE OF DELIVERY: with insulation, Thermal protection device, Domestic water heater for EKO boilers, Thermometer, Cleaning kit. Models EKOs 12 and 14 are not delivered with the domestic water heater Firewood Fireplace Delivery Heater Required Weight Weight model power size tube water water draft EKO s EKO DIMENSIONS (mm) EKO quantity quantity EKO-s kw dm 3 R l l Pa kg kg L B Eko s Eko D F G d 12 8-12 52 5/4 84 18 230 620 470 1150 980 550 525 130 14 10-15 52 5/4 97 18 240 620 470 1150 980 550 525 130 25 20-25 80 5/4 115 115 20 260 320 655 640 1170 1830 930 540 550 160 30 25-30 97 5/4 115 126 21 270 330 755 640 1170 1830 920 540 550 180 35 30-35 100 5/4 115 120 21 285 340 755 640 1170 1830 920 540 550 180 40 35-40 114 5/4 140 144 24 310 380 855 640 1170 1830 920 540 550 180 50 40-50 165 6/4 140 160 25 350 420 855 740 1380 1930 1100 685 450 200 65 50-65 167 6/4 170 195 27 450 535 1020 820 1380 1930 1100 765 520 220 80 65-80 167 6/4 170 185 27 470 555 1020 820 1380 1930 1100 765 520 220 100 80-100 180 2 170 210 30 560 645 1120 880 1480 2030 1200 765 620 220 12 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

WOOD-FUELED HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER HS HS boilers were developed on the basis of long years of experience in the field of development and production of heating equipment. s are intended for burning all types of wood. They are distinguished by long inclined loading doors and a large combustion chamber which allow simple use and loading of the boiler with large quantities of fuel. Chimney connection is located at the back side of the boiler. s are equipped with a combustion chamber and a pipe register with turbulators for better heat exchange. Chimney must be constructed in accordance with the SCHIEDEL table for solid fuel boilers. Draft must comply with the values stated in the table for the selected model of the boiler. Construction of the fireplace and the perfect insulation guarantee maximum fuel efficiency. s are to be loaded transversally with firewood of up to 36 cm in length. Fuel burns in the lower side part of the boiler. Installation of the grate in the fireplace and installation of the flap on the secondary air door significantly improve the combustion process. The installed return water preheater and the water-cooled grate prevent the low-temperature corrosion. Easy access to all internal surfaces allows easy cleaning and maintenance. By purchasing additional burner control and special burner doors, your boiler can be rearranged to burn fuel oil. For domestic water heating you must connect the boiler with a self-standing water heater, because the construction of the boiler does not enable you upgrade boiler with a heater. s are distinguished by quality production as they are made with laser cutting of metal sheet and robot welding. s are also factory equipped with a thermal protection device. SCOPE OF DELIVERY with lining and insulation Thermometer Cleaning kit LEGEND 1. Fireplace loaded with firewood 2. Flue pipes 3. Exhaust of flue gases with a flap 4. Water-cooled grate 5. Ash space, drawer 6. Pipe register cleaning opening 7. Return water preheating 8. Return tube 9. Delivery tube 10. Panelling with insulation 11. Loading doors 12. Doors for cleaning and relighting the fire 13. Primary air flap 14. Safety tube 15. safety flow, supply, discharge 16. draft control fitting R ¾ 17. connection thermometer sensor R ½ 18. Protection door vertical grate 19. Fireproof clay 20. Mixing channel 21. Secondary air rotating flap 22. Thermal protection device Model HS Loading Firewood door power dimensions kw Fireplace size dm 3 Chimney connection Ø water quantity l Required draft Pa Weight kg Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of 0.40. Delivery Heater and return coonnection tube R R DIMENSIONS (mm) L B H L1 H1 A D 26 260x400 20-25 52 160 55 20 280 5/4 1 720 560 975 840 150 900 785 32 260x400 25-32 74 180 85 23 330 5/4 1 820 650 1035 940 150 950 830 44 260x400 35-43 88 200 100 25 410 5/4 1 875 650 1135 1000 150 1070 930 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 13

WOOD-FUELED HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER CENTRAL 28 Stadler Central series boilers are constructed fur burning firewood. Combustion in the lower side part and the vertical 4-draft conduction of flue gases enable good transmission of flue gas heat to the heated water. Combustion in the lower side part classifies the boiler in the series of slow-burning boilers which means that the loading interval is longer than with other types of boilers. Fireplaces are adapted to standard firewood lengths. Fireplace of the Central 28 boiler is adapted to be loaded with 33 cm long firewood. Special channel for the conduction of combustion air to individual combustion zones enables good combustion of fuel. The Central 28 boiler is equipped with a special fireproof clay combustion chamber where the previously not combusted flue gases in the fireplace are burnt. s also come equipped with a combustion grate made of grey cast iron which can be moved, thus enabling you to remove the ashes from the grate during the operation of the boiler. Additionally, the boilers are equipped with a thermal protection device and draft control. Vertically installed cleaning openings enable easy access to internal vertical channels. Construction of boilers respected all regulations related to boiler construction like DIN 4751 B1.1; DIN 4702, EN 303-5. s are equipped with the CE 0036 marking. s are also factory equipped with a thermal protection device. ESSENTIAL ADVANTAGES OF THE STOREY HEATING BOILER: Good efficiency and minimum environmental nuisance, Automated draft control enables slow-burning, Moving grate enables cleaning during operation, Single load is sufficient for several hours of burning, The boiler is adapted to burn firewood and certified for German market. The use of certified materials provides long service life of the boiler. L SCOPE OF DELIVERY with lining Thermometer Draft control Cleaning kit C28 B1 128 B1 128 128 C 24 C 28C 24 C 28 H3 H3 H3 H2 H1 H1 H2 H H1 B1 B B L1B1 L1 B L1 B1 model CENTRAL Heat power kw Fireplace size dm 3 water quantity l Chimney Chimney Connection Ø Ø mm mm Required draft Pa Outflow inflow R Weight kg DIMENSIONS (mm) L L 1 B B 1 H H 1 H 2 H 3 28 15-19 55 55 160 130 20 1 250 660 180 797 70 1070 788 885 125 14 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

WOOD-FUELED HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER CENTRAL 17 IN 23 Storey boilers are intended for installation and use in non-basement residential houses and residential apartment blocks with no central heating and no chance of classic boiler room installation. Combustion in the lower side part classifies these boilers in the series of slow-burning boilers which means that the loading interval is longer than with other types of boilers. s are extremely energy saving, thus making the fuel consumption of a single heating season very low. Dimensions and visual appearance are adapted for installation in fitted kitchens. The central heating installation should be executed in a way that enables horizontal connection to the heating system (at the side of the boiler). Such installation enables the boiler to be levelled with the edge of the kitchen working counter. Pipes routed vertically behind the boiler will cause the boiler to be unaligned with the fitted kitchen. s are equipped with a three-way chimney connection and vertical chimney connection with a cover. They are appropriate for burning of dry firewood of up to 25 cm in length. s should be connected to an Ø 118 mm diameter chimney (23 kw boilers to Ø 128 mm). Chimney draft should equal to 20 Pa. We recommend you to measure the chimney prior to the installation of the boiler. In case of low quality chimneys, such chimneys should be arranged to enable optimal operation of the boiler. All boilers are equipped with a thermal protection device, whilst new models come with a flexible loading cover enabling easier fuel loading. ESSENTIAL ADVANTAGES OF THE STOREY HEATING BOILER: Installed cooking plate allows reheating of your dishes, Room with the installed boiler does not require additional radiators, Good efficiency and minimal environmental nuisance, Automated draft control enables slow-burning, Moving grate enables grate cleaning during operation of the boiler, Single load is sufficient for several hours of burning, Use of certified materials provides long service life of the boiler. SCOPE OF DELIVERY C17 C23 with lining Thermometer Draft control Cleaning kit Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of 0.40. 600 161 300 134 200 1" 1/2" 3/4" 35 3/4" 70 1" 1/2" 850 C 23 C 17 C 23, C 17 H 785 130 1" 40 3/4" 556 610 3/4" 1" 70 260 1/2" 660 600 400 model CENTRAL Heat power kw Power (water) kw Power (environment) kw Container dm 3 Burner water quantity l Chimney Connection Ø mm Required draft Pa Outflow inflow R Weight cca 17 8-12 14 3 35 35 118 10-15 1 132 740 23 10-18 19 4 46 40 128 15-20 1 198 718 kg H mm WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 15

DUAL FIREPLACE FIREWOOD AND FUEL OIL CENTRAL HEATING BOILERS MODEL: STADLER TOBI Stadler TOBI central heating boilers are constructed as extremely energy saving boilers due to the installation of fuel oil and firewood boilers in a single construction. Both boilers use a single water reservoir, but completely separated fireplaces. Such design enables automatic rearrangement from burning of one type of fuel to another which cannot be achieved with combined boilers. s are basically intended for burning firewood in the 90/70 C operating mode. The fuel oil part of the boiler activates automatically after all of the fuel from the firewood fireplace has been used and the temperature dropped under the preset value. The fuel oil part of the boiler does not activate if the firewood fireplace is full and the preset temperature is reached. In case you deactivate the automatic system, these boilers only operate by burning firewood. A more modern construction concept classifies these boilers among the new generation of eco-friendly products as they operate in a similar way as hybrid cars. The firewood fireplace is equipped with modern burning in the lower side part of the boiler which enables controlled long burning process lasting even over 3 ½ h. The fireplace allows you to burn 33 cm long firewood. s are equipped with a return water preheating system and a cast iron grate which improves firewood combustion processes. Loading doors allow loading of large pieces of firewood. The special fireplace constructed for burning fuel oil is equipped with a hot combustion chamber and a turbulator in the third draft. Its design enables top-class efficiency of over 93%. Combusted flue gas emissions reach even more favourable parameters than required by law. The fuel oil part of the boiler is equipped with the SELTRON control. These boilers cannot be upgrades with domestic water heaters. Domestic water heaters can be installed as separated units which are then connected to the boiler. Ba purchasing the domestic water heater additionally, it is possible to control the temperature in the domestic water heater with the help of a pump. panelling is enamelled in the RAL 3000 or RAL 2004 colour combination. Our boilers are in compliance with all regulations regarding safety at work. Construction of the boiler is produced in accordance with regulations DIN 4751 B1.1, DIN 4702, EN 303-5, and is equipped with the CE 0036 marking. s are also equipped with a thermal protection device. The central heating system must compulsory include one of the system for lifting the return water as this is the only way to use the boiler with lower powers. If the boiler is not connected with the system for lifting return water the boiler condensates and causes poor combustion. This special pump with a three-way valve ensures that the boiler first reaches the temperature of 60 C, and emits only the excess energy into the system. At the same time it prevents the return water with temperatures lower than 55 C to enter the boiler, thus preventing the condensation. If the system includes a hot water accumulator, the three-way mixing valve enables the accumulator to be filled. With the use of the hot water accumulator, better operation of the burning device can be achieved, especially during the transition periods when temperatures are not too low, but still demand heating. model TOBI Power (fuel oil) kw Power (wood) kw Fireplace size dm 3 water quantity l Required draft Pa Weight kg Chimney Connection (fuel oil) Ø Chimney Connection (wood) Ø width mm height mm Required door width to enter the boiler with panelling into the room Required door width to enter the boiler without panelling into the room Efficiency (fuel oil) 20 15-20 20 86 105 15 230 130 160 990 1200 850 770 93,2 81,2 25 20-25 25 86 100 20 240 130 160 990 1200 850 770 93,4 81,5 % Efficiency (wood) % 16 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

FIREWOOD AND FUEL OIL HOT WATER CENTRAL HEATING BOILERS MODELS: STADLER EKOs and RLs These devices include two separate boilers. The basic boiler is the firewood boiler onto which the fuel oil boiler or gas oiler is installed. The firewood boiler is reinforced with two holders which enable safe installation of the fuel oil or gas boiler. Each boiler represents the best solution for itself as it is in compliance with all ecology standards. The boiler can additionally be upgraded with a separate domestic water heater, whilst the heating control takes place via the external control. Stadler EKOs heating boilers are constructed in accordance with new findings concerning wood combustion processes. Fireplaces are adapted for standard firewood lengths (33cm and 50cm). The construction of the fireplace also allows loading of somewhat longer logs. Permissible cutting length equals to +6 cm, thus enabling you to load the boiler with firewood of up to 40 or 56 cm in length. s EKOs 25 are to be loaded with 33cm long firewood, whilst boilers EKOs 30-40 are to be loaded with 50cm long firewood. s are designed for operation in the 90/70 C mode, whilst their return water preheating system improves the thermal load of the boiler. The new way of conduction of flue gases improves the combustion processes during firewood burning. Large loading doors enable easy loading of firewood into the fireplace. s can be loaded with large quantities of firewood, therefore we recommend you to burn your fuel in a downwards direction, thus prolonging the combustion time of a single load. L1 B1 H1 d G1 D1 50 H L B d F1 G F D Special Stadler RLs fuel oil and gas boilers are produced with welded frameworks made of larger dimensioned materials. fireplaces are equipped with a hot reversible chamber and turbulators within the pipes which allow combustion with efficiency of over 93%. Flue gas exhaust emissions are lower than required by law, especially NOx, CO, whilst the flue gas temperatures in the chimney do not reach 180 C. s are in compliance with all currently valid provisions on safety and construction design (DIN 4751 BI.1, DIN 4702, and EN 303-5). The basic equipment includes also the control cabinet for the regulation of the burner operation. Power Fireplace Required Weight Delivery L B H D F G d model les size water draft EKOs tube quantity EKOs kw dm 3 mm mm mm mm mm mm mm l Pa kg R 25 20-25 80 115 20 260 675 640 1170 930 540 550 180 5/4 30 25-30 97 126 21 270 785 640 1170 910 540 550 180 5/4 35 30-35 100 120 21 285 785 640 1170 910 540 550 180 5/4 40 35-40 114 144 24 310 855 640 1240 910 540 550 180 5/4 Power Required Weight Delivery L 1 B 1 H 1 D 1 F 1 G 1 d model (fuel oil) water draft MVs tube quantity mm mm mm mm mm mm mm RLs kw l Pa kg R 25 15-30 105 15 155 665 645 720 475 230 400 130 5/4" 35 30-40 95 15 190 665 645 720 475 230 400 130 5/4" WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 17

FUEL OIL HOT WATER CENTRAL HEATING BOILERS MODELS: STADLER RL and RLs Special welded Stadler RL boilers are constructed for burning fuel oil or gas and are made of the thickest certified sheet metals. fireplaces are equipped with hot reversible chambers and turbulators within the pipes which allow top-class combustion efficiencies of over 93%. Combusted flue gas emissions reach even more favourable parameters than required by law. The boiler is in compliance with all currently valid provisions on safety and construction design (DIN 4751 BI.1, DIN 4702, and EN 303-5). RL marked boilers are equipped with vacuum enamelled heaters for preparation of domestic hot water. Domestic hot water temperature can be controlled with the help of the pump. RLs boilers are delivered without the heater for preparation of domestic hot water. These boilers are distinguished by good 50 mm thick insulation. The panelling of the boiler is protected with powder enamelling. The basic equipment also includes the control cabinet for the control of burner operation. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of 0.40. SCOPE OF DELIVERY RL RLs with lining and insulation control Water heater control If the delivery includes the base of the boiler it is necessary to consider its height of 270 mm. Hot combustion chamber and turbulators Cleaning brush L B As optional equipment you can install an electric heater (2 kw) for domestic water heating during the summer. We recommend you to purchase the additional heater at the time of your order, as the subsequent installation is more expensive and complex. Hs G F D H Power Water Flow Weight Weight Chimney model water heater return RL RLs DIMENSIONS (mm) RLs, RL kw quantity l l R kg kg Ø mm L B H Hs D F G 25 15-30 105 115 5/4 225 155 130 665 645 1270 720 475 230 400 35 30-40 95 115 5/4 260 190 130 665 645 1270 720 475 230 400 50 40-60 135 140 5/4 300 220 160 815 645 1270 720 475 230 400 80 60-90 225 170 6/4 395 315 180 955 790 1450 900 650 370 450 100 90-110 240 170 2 330 200 200 1060 790 1450 900 635 365 450 18 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

FIREWOOD HOT WATER HEATING BOILERS MODEL: HDG Euro HDG Euro boilers are distinguished by very long loading intervals and efficiency of over 90%. They are effective, energy saving and comfortable for the user. Flue gas emission values are lower than all of the prescribed values. Contraction and production of the boiler are in accordance with all safety regulations. These boilers were granted the German innovation award and are equipped with the TÜV quality marking. Large fuel loading space significantly increases fuel reloading intervals. Cleaning of the boiler is easy as its doors are positioned in a way which enables easy access. s are delivered with installed panelling and are connected immediately. Connection with the power supply is very simple, as boilers include already prepared wiring with plug equipped cables. Combustion takes place in the lower side part of the boiler on the grate which allows wide selection of fuels. Along with the special combustion chamber, the robust and innovatively constructed burner nozzle provides swirling mixing of flue gases which ensures optimal combustion. After the combustion has finished, the flaps shut down and the fan deactivates. This prevents the boiler from cooling, whilst the next ignition is facilitated by the remaining charcoal. Grates are massive and equipped with a practical cleaning opening. The loading shaft is made of 10 mm thick quality steel sheet. Pneumatic cylinders facilitate opening of shaft doors. The system bolt of the loading shaft cover enables safe loading. The spacious conical loading shaft can be filled with firewood or bulk material. If you select the right size of the device, you will be able to get the necessary heating energy with only one loading of the boiler daily. Planning of the central heating system must include a hot water accumulator as such reservoir combined with the boiler control guarantees environment friendly combustion. The hot water accumulator significantly increases comfort of burning as it takes over the excess energy and transfers it back if necessary. The correct selection of the hot water accumulator enables very long loading intervals. During the summer, burning of a single load can be sufficient for several days of domestic water use. Volume of the accumulator depends on customer s demands regarding comfort, boiler power, volume of the loading shaft and the consumption of hot water for room heating. Combination of the firewood boiler equipped with the hot water accumulator and the solar energy device meets the demands of the modern heating system. Lambda control enables very low emission values, high efficiency and low fuel consumption. The adjustable primary and secundary air motors provide accurate amounts of combustion air to specific combustion areas. Primary air takes care for uniform combustion power, whilst the secundary air takes care for the lowest emission values and high efficiency throughout the combustion process. Predtok 1 1/4 792 1606 Lambda Control constantly measures and displays the following parameters: Quantity of the remaining oxygen in flue gases, Temperature of flue gases for uniform efficiency, Temperature of the heating boiler and water reservoir, Lifting of the temeperature of the return water. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of 0.40. Model Heat power 1184 1106 220 110 0180 110 Povratni tok 11/4 88 88 objemka za praznjenje/ polnjenje 1/2 783 Vnosna mera 813 599 1920 1990 1 150 104 5 Območje odpiranja 510 1255 For more information, please contact the manufacturer, local salesman or the assembler and ask for a detailed brochure Lowest Loading Loading space Chimney Operating Required Max. flow boiler space width and water connection pressure draft weight temperature power volume depth quantity Ø C kw kw l mm l mm Bar Pa kg HDG Euro 30 30 29 220 560 x 407 162 180 3 13 95 940 2000 HDG Euro 40 40 29 220 560 x 407 162 180 3 13 95 953 2500 HDG Euro 50 50 29 220 560 x 407 162 180 3 13 95 979 3000 1514 1374 Recommended accumulator size l WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 19

FIREWOOD HOT WATER HEATING BOILERS MODEL: HDG Turbotec 2 4 3 1 5 6 LEGEND 1. Loading space (340 l), 2. Cleaning opening, 3. Lambda probe and the flue gas sensor, 4. Fan, 5. Loading from above optional and with additional payment, 6. HDG lambda control, 7. Loading doors - front, 8. Primary and secondary air control, 9. Cleaning opening. 7 9 8 Thermal protection device sensor 1 / 2 VL 1 1 / 4 varnostni toplotni izmenjevalec 1 / 2 RL 1 1 / 4 Praznjenje 1 / 2 820 576 743 HDG Turbotec boilers are firewood heating boilers with large loading space of up to 340 l. they are intended tu burn firewood with lengths of up to 1 m, thus prolonging the interval between loadings. In case you have fine fuel at your disposal, you can also additionally order the upper boiler loading doors. Turbotec boilers are distinguished by very long loading intervals and efficiency of over 90%. They are effective, energy saving and comfortable for the user. Flue gas emission values are lower than all prescribed values. Construction and production of the boiler are in accordance with all safety regulations. They are ideal for use in the craft industry, agriculture and forestry, and are equipped with the TÜV quality label granted by a German institution. Cleaning of the boiler is easy as its doors are positioned in a way which enables easy access. s are delivered with installed panelling and are connected immediately. Connection to the power supply is very simple, as boilers include already prepared wiring with plug equipped cables. The robust and innovative constructed nozzle provides good combustion. The interior of the combustion chamber is shielded with fireproof concrete. Swirling of flue gases in the combustion chamber provides optimal combustion. After the combustion has finished, the flaps shut down and the fan deactivates. This prevents the boiler from cooling, whilst the next ignition is facilitated by the remaining charcoal. s are made of quality steel sheet. Primary and secondary air servomotors deliver the necessary air directly in the combustion zone. Primary air takes care for constant performance of the boiler, whilst the secondary air takes care for the lowest flue gas emission values. If you select the right size of the device, you will be able to obtain the necessary heating energy with only one loading of the boiler daily. Planning of the central heating system must include the hot water accumulator as such accumulators combined with the boiler control guarantee environment friendly combustion. Installation of the hot water accumulator significantly increases comfort of burning as it takes over the excess energy and transfers it back if necessary. The correct selection of the hot water accumulator enables very long loading intervals. During the summer, burning of a single load can be sufficient for several days of domestic water use. Volume of accumulators depends on customer's demands regarding comfort, boiler power, volume of the loading shaft and the consumption of hot water for room heating. HDG Turbotec boilers are equipped with HDG lambda control 1 which ensures very low emission values, high efficiency and low fuel consumption. Adjustable primary and secondary air motors deliver accurate amounts of combustion air to specific combustion areas. Primary air takes care for uniform combustion power, whilst the secundary air takes care for the lowest emission values and high efficiency throughout the combustion process. 1394 1218 540 280 180 270 576 1939 1785 1606 60 Power Loading Loading Loading Chimney Required Operating Max. flow Model space volume space depth space width water quantity connection Ø draft pressure temperature weight kw l mm mm l mm Pa Bar C kg HDG Turbotec 50 L 50 340 1100 540 370 180 15 3 95 940 HDG Turbotec 60 L 60 340 1100 540 370 180 15 3 95 940 20 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

HDG WOOD CHIP AND WOOD PELLET HEATING SYSTEMS MODEL: HDG Compact These boilers are appropriate for burning wood pellets and wood chips with humidity of up to 45%. s can also burn Class 6 and 7 fuels. The compact and favourable priced versions are appropriate for use in households, agriculture, craft industry and public institutions, basically everywhere where a reliable and economic operation is required. Constant power is provided by the automatic technology of angled or movable grates. s are equipped with automatic ignition via the hot air fan. Two large external ash collectors make operation and maintenance easy. s are distinguished by low emission values and optimum efficiency of over 90%. The reliable fuel loading technology and the fire extinguishing device provide absolutely safe operation. Cell block is especially accurately manufactured and takes care for proper loading. Vertical surfaces of the heat exchanger provide better heat transfer. In emergency situations boilers can also burn firewood. HDG Compact electronic control device of the boiler takes care for good combustion technology and is a product of our development programme. It can also be upgraded for control of different heating systems. All actual conditions of the operating device are shown on the display. Fuel loading takes place directly on combustion grates. Fuel supply and primary and secondary air can be adjusted independently. Even in case of bigger shares of non-combustible materials, the power stays constant due to the technology of angled grates. After reaching a certain loading level, the fuel ignites with the help of hot air. Automatic ignition increases the device control comfort. Device operates with optimum emission values. You should prevent long lasting smouldering during the time of ember preservation, thus preventing the contamination of heat exchanger and chimney surfaces. In combination with the fire extinguishing equipment, loading of the boiler via the patented cell block and feeding stoker guarantees perfectly safe operation. With the help of the cell block, the combustion chamber is completely separated from the silo and the transport unit and represents patented protection from the return fire. The next advantage lies in cutting of large firewood by the cell block into smaller pieces, thus creating ideal combustion conditions. The circular skimming device for takeover of wood mass from the silo is appropriate for simple, unproblematic takeover of wood chips, wood pellets, wood shavings, sawdust and wood briquettes from the silo. Maximum stoker length is 6 m (max. weight of fuel = 250 kg/m3). The takeover device can be installed also in larger containers, provided that they do not require complete emptying. Two pretightened joint levers are equipped with rotating spring feathers which rotate and skim the wood mass onto the stoker. Material takeover takes place along the transverse and open transport stoker. In case of square and round containers (6 m diameter) emptying takes place with the transverse stoker. The loading system can be installed in different positions in 180 radius according to the option of the silo connection. These systems are described in details in technical brochures. Our experts will make a special offer with technical solutions which meet the customer's demands for each individual device. For more information, please contact the manufacturer, local salesman or the assembler and ask for a detailed brochure. Power Power Combustion Combusted air water Operating Required Flow Model area gas temperature flow quantity quantity pressure draft temperature weight kw kw C g/s l Bar Pa C kg HDG Compact 25 26 7,7 26 140-180 19,0 110 3 7 95 650 HDG Compact 35 35 8 35 140-180 26,8 110 3 7 95 650 HDG Compact 50 50 12 50 100-240 32,6 167 3 13 95 980 HDG Compact 65 65 12 65 100-240 45,1 167 3 13 95 980 HDG Compact 80 80 23 80 100-240 52,0 221 3 16 95 1200 HDG Compact 100 100 30 100 100-240 74,6 210 3 20 95 1540 HDG Compact 150 150 45 150 100-240 111,9 450 3 20 95 2140 HDG Compact 200 190 57 190 100-240 147,6 450 3 20 95 2220 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 21

FUEL OIL HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER Z doors open in the left and right direction, thus allowing easy access to flue pipes. Access to the flame pipe is enabled after removing the burner. s are equipped with the basic control and safety equipment. For higher levels of modern heating systems regulation, control equipment of the most renowned foreign manufacturers is used. Stadler Z heating boilers are Slovenian products with a high level of installed technology. Their new construction is a result of Slovenian knowledge, long years of experience and continuous development and improvement. They are planned with a 3D construction technology which provides precise design of each part of the boiler. The modern construction design is based on the triple draft principle. Flue pipes are not equipped with turbulators. s are constructed in accordance with high environmental standards and are produced in standard versions for operation with 4 bars of overpressure. For higher pressures (>10 bar), modified construction is used. You can choose between 90/70 C and 110/90 C operating modes. The ideal construction and the flame pipe type of flue gas conduction provide optimum combustion with efficiency of over 95%. Such efficiency means almost perfect combustion with minimum flue gas emissions which is, at this time of environmental awareness, more and more important. Products are equipped with the CE 0036 marking. s are intended for burning liquid or gas fuels. Advantageous boiler dimensions allow installation in small areas. Operation of our boilers is good even in case of saccadic and oscillating loads. Operation resistance is minimal, whilst the operation is very quiet. s are well insulated and installed on a stable support frame. On the top, boilers are equipped with walkable covering made of ribbed sheet metal which facilitates the installation and later maintenance operations. Larger boilers are equipped with railings intended for cleaning and supply and with the entrance and exit ladder. B SCOPE OF DELIVERY with left or right opening doors fixation panel Electric switch cabinet Lacquered pannelings with insulation Z Flue Model Heat Flue Safety Supply power water pipe return tubes discharge weight B D E F H H quantity 1 I K L L 1 L 2 Ø cca Z kw l mm DN DN R kg 130 80-130 170 810 585 635 900 1060 1190 790 200 1035 1400 220 200 80 40 2 405 180 130-180 235 860 595 660 955 1120 1360 850 250 1165 1550 240 230 100 50 2 555 230 180-230 280 860 595 660 955 1120 1360 900 250 1365 1750 240 230 100 50 2 660 290 230-290 330 895 595 685 955 1170 1360 1055 250 1465 1850 240 230 100 50 2 750 350 290-350 340 895 595 685 955 1170 1360 1055 250 1565 1950 240 230 100 50 2 820 450 350-460 805 1145 630 830 1200 1440 1640 1500 250 1800 2170 230 280 100 50 2 1180 580 460-580 815 1145 630 830 1200 1440 1640 1500 250 1900 2270 230 280 100 50 2 1335 700 580-690 930 1215 695 870 1245 1505 1795 1755 300 2145 2560 280 280 150 65 2 1665 850 690-850 885 1215 695 870 1245 1505 1795 1755 300 2285 2710 280 280 150 65 2 1880 1050 850-1050 1350 1320 700 920 1285 1605 1835 1845 300 2460 2860 255 330 150 65 2 2240 1250 1050-1250 1360 1320 700 920 1285 1605 1835 1845 300 2660 3060 255 330 150 65 2 2625 1600 1250-1600 1520 1370 670 950 1335 1660 1970 2195 350 3025 3470 270 370 200 100 2 2905 2300 1800-2300 2800 1565 880 1150 1660 1985 2345 2750 350 3640 4130 310 470 200 100 2 4790 2900 2400-2900 3250 1690 950 1220 1775 2150 2440 3570 350 4230 4730 325 470 200 100 2 6650 3500 3000-3500 3750 1905 1030 1300 1960 2256 2640 3580 350 4520 5110 420 470 200 100 2 8100 4500 4370-4700 4950 2400 2100 1500 3100 2700 3100 1560 2800 5020 5900 705 600 200 100 2 11500 5000 4800-5560 5600 2400 2100 1500 3100 2700 3100 1560 3500 5720 6600 755 600 200 100 2 12900 22 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

LOW PRESSURE STEAM BOILERS MODEL: STADLER ZP Stadler ZP low pressure steam boilers are used for production of steam with overpressure of 0.5 bars. They are Slovenian made with a high level of installed technology. Their new construction is a result of Slovenian knowledge, long years of experience and continuous development and improvement. They are planned with a 3D construction technology which provides precise design of each part of the boiler. The modern construction design is based on the triple draft principle. Flue pipes are not equipped with turbulators. s are constructed in accordance with high environmental standards. The ideal construction and the flame pipe type of flue gas conduction provide optimal combustion with efficiency of over 95%. Such efficiency means almost perfect combustion with minimum flue gas emissions which is, at this time of environmental awareness, more and more important. Products are equipped with the CE 0036 marking. s are intended for burning liquid or gas fuels. Advantageous boiler dimensions allow installation in small areas. Operation of our boilers is good even in case of saccadic and oscillating loads. Operation resistance is minimal, whilst the operation is very quiet. s are well insulated and installed on a stable support frame. On the top, boilers are equipped with walkable covering made of ribbed sheet metal which facilitates the installation and later maintenance operations. Larger boilers are equipped with a ladder and walkable platform with railings. doors open in left and right direction, thus allowing easy access to flue pipes. Access to the flame pipe is enabled after removing the burner. s are equipped with the basic control and safety equipment. For higher levels of modern heating system regulation, control equipment of the most renowned foreign manufacturers is used. SCOPE OF DELIVERY Low pressure steam boiler with left and right opening doors Two-colour lacquered panneling with insulation Base plate for the installation of the burner Operation and safety pressostats (3 pcs) Level switch Inspection glass (2 pcs) Pressure gauge Pressostat installation fitting ZP Model Power Steam Steam Safety Condense DN Flue quantity takeover tubes tubes pipe weight A B C D H H1 H2 H3 H4 L L1 Ø cca ZP kw kg/h DN1 DN2 DN3 R mm kg 130 80-130 180 80 50 40 2 1400 810 205 435 1445 900 635 1060 585 1035 220 200 450 180 130-180 250 80 50 40 2 1550 860 205 490 1495 955 660 1110 595 1165 240 230 600 230 180-230 320 80 50 40 2 1750 860 245 490 1495 955 660 1110 595 1365 240 230 700 290 230-290 400 80 50 40 2 1850 895 225 580 1545 955 685 1160 595 1465 240 230 820 350 290-350 520 100 65 40 2 1950 895 205 680 1545 955 685 1160 595 1565 240 230 870 450 350-460 640 100 65 40 2 2170 1145 250 700 1980 1200 830 1430 630 1800 230 280 1750 580 460-580 800 125 65 40 2 2270 1145 250 800 1980 1200 830 1430 630 1900 230 280 1840 700 580-690 960 125 65 40 2 2560 1215 455 865 1870 1245 870 1470 695 2145 280 280 2000 850 690-850 1170 150 80 40 2 2710 1215 455 1015 1870 1245 870 1470 695 2285 280 280 2140 1050 850-1050 1450 150 80 40 2 2860 1320 500 1100 2000 1285 920 1595 700 2460 255 330 2 650 1250 1050-1250 1920 200 100 40 2 3060 1320 500 1300 2000 1285 920 1595 700 2660 255 330 2940 1600 1250-1600 2200 200 100 40 2 3470 1370 615 1415 2120 1335 950 1650 670 3025 270 370 3450 2300 1800-2300 3200 250 125 40 2 4130 1565 850 1560 2440 1660 1150 1925 880 3640 310 470 5650 2900 2400-2900 4000 2x200 150 40 2 4730 1690 500+875 1585 2620 1775 1220 2070 950 4230 325 470 7500 3500 3000-3500 4800 2x200 150 40 2 5110 1905 500+930 1640 2800 1960 1300 2250 1030 4520 420 470 9320 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 23

GAS AND FUEL OIL HOT WATER BOILERS MODEL: STADLER ZV In these times, when the environmentally aware part of the world tries to lower the emissions of greenhouse gases into the environment, it is very important that the fossil fuels heating systems operate as efficiently as possible, with perfect combustion, and low fuel consumption. Our company already several years ago decided to actively contribute to the development of such heating devices with no impact to the environment. On the basis of 40 years of tradition in the field of boiler production and intensive investments into development, our company produced a new family of hot water boilers named STADLER ZV. These boilers are constructed on the triple draft principle with low Nox emissions. Due to the low load of the combustion chamber ( 1,2 MW/m3) and the conduction of flue gases through the pipe register, these boilers provide optimum combustion with top-class efficiency. s are made in accordance with Directive 97/23/CE PED and the Slovenian SIST EN12953 standard regarding gas or fuel oil burning. s are also equipped with a substantially dimensioned heat part. At the time of dimensioning of flame pipes, flue pipe packages and the water part, special attention was given to thermodynamic compliance and fast transfer of temperature to the water. s are also equipped with large volume water parts appropriate for optimum temperature control in different operating conditions. Inspection openings for entrance into the water part are easily accessible and allow easy access. s are well insulated and installed on a support frame. The operating overpressure is adapted to customer's demands. Our company produces boilers intended for pressures of 6-16 bars with the maximum operating mode of up to 160 C depending on the order or the investor's temperature mode. Minimum operating mode equals to 60 C. The external boiler fitting must provide protection of the hot water boiler against too low temperatures of the return tube. Equipment of the boiler can also include the system for protection against condensation. Good boiler insulation prevents heat loss into rooms and enables stable thermal operation. s are insulated with two layers of 60 mm thick Type ZV Heat power water quantity Transport weight Operating weight water side flue side Flue side volume width lengt height kw l 6 bar 16 bar 6 bar 16 bar mbar mbar m 3 B L H 800 800 1300 2250 2650 3550 3950 20 6,3 1,3 1350 2850 1650 1000 1.000 1800 2550 2950 4350 4750 55 6,7 1,6 1550 2900 1850 1500 1.500 3800 3500 4000 7300 7800 57 7,2 2,6 1750 3750 2000 2000 2.000 5000 5200 5800 10200 10800 52 8 3,2 1850 4150 2100 2500 2.500 6000 6500 7600 12500 13600 65 8,6 4,2 1950 4350 2200 3000 3.000 7200 6900 8200 14100 15400 84 9,8 5,1 2000 4600 2250 4000 4.000 8000 9100 10300 17100 18300 145 8,7 5,8 2100 5200 2350 5000 5.000 9500 10500 11800 20000 21300 120 11,5 6,3 2300 5500 2550 6000 6.000 11500 13600 16200 25100 27700 164 11,7 8,3 2550 5800 2800 7000 7.000 17500 19500 23000 37000 40500 170 12,5 8,8 2850 6775 3200 8000 8.000 19000 21500 25300 40500 44300 155 11,5 12,3 2900 7250 3250 9000 9.000 21000 24200 27600 45200 48600 167 13,2 14,7 3000 7600 3400 10000 10.000 22800 25100 28500 47900 51300 156 13,5 16,7 3100 7950 3500 12000 12.000 25500 27300 34500 52800 60000 172 12,5 19,4 3200 8150 3600 24 15000 15.000 28000 35000 43000 63000 71000 163 14 23,5 3400 8500 3800 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

LMF10 ALUR lamella insulation which makes total insulation 120 mm thick. Construction of the boiler enables to connect the burner to a special flange, which is to be installed on the neck of the combustion chamber. Combined with»low NOx«burners, our boilers achieve very low emission values (NOx < 100 mg/kwh). These boilers are equipped with double doors at the front side which open in the left and right direction, thus enabling easy access to pipe exchangers. Back side of boilers includes inspection opening of the combustion chamber, opening for the control of the flame and the flue cabinet. The flue cabinet is equipped with inspection covers and the pipe with a valve for condensate discharge. The flue cabinet can also be installed with a motorised flue flap for prevention of ingress of cool air into the boiler when it operates in idle mode. Above the flue cabinet, it is possible to install a heater for reduction of flue gas temperature which additionally increases the efficiency of the device and lowers the fuel costs. Such installation can lower the fuel consumption for up to 10%. The equipment of the heater can also include the system for protection against condensation. Lower fuel consumption enables additional decrease of CO2 emissions and lesser impact on the environment. Low resistance at flue gas and water sides, low radiation loss, and simple maintenance and cleaning represent additional advantages of these boilers. equipment includes safety equipment in accordance with SIST EN12953 standard, including the intermediate flange piece for installation of the safety and control equipment. The quality control of Weishaupt burners enables top-class control of the combustion process. Our company upgrades the Weishaupt control cabinets in such way, that they also allow the control of peripheral systems in the boiler room. Output signals of the boiler and control cabinet enable the regulation and control of the operation via the CNS. If the boiler room contains several boilers, they can be controlled via the cascade regulation with diagnostics of the device operation. s are equipped with the platform and a ladder. On the top, boilers are equipped with walkable covering made of ribbed sheet metal which facilitates the installation, operation control and maintenance operations. Our company manages all inquiries in a project way and adapts boilers to customer's demands. At the investor's demand, the company can take care for complete delivery of the equipment with all installations. In the name of the investor, our company can also elaborate all necessary documents for the preparation and execution of the project, and the technical acceptance. Modern 3D planned ZV boiler 's cross section shows the construction design which provides combustion with low flue gas emissions. Substantially dimensioned material cross sections do not burden the materials and prolong the service life. s are distinguished by the modern laser and CNC technology machining, whilst joint welding is performed with the help of powder welding processes. Welding is strictly controlled by the internal control and outside institutions. Type ZV Torch Burner Flue Flue Flow, Flow, Flow, Safety Safety Safety Water Bleeding diameter connection height connection connection height return PN 16 return PN 16 return PN 16 valve 6 bar PN 16 valve 8 bar PN 16 valve 16 bar PN 16 discharge Ø H1 Ø H2 20 C 30 C 40 C DN DN DN PN 40 PN 40 800 630 630 250 1260 100 80 80 40 32 32 40 40 1000 660 730 250 1510 100 80 80 40 32 32 40 40 1500 730 850 350 1610 125 100 100 50 40 40 40 40 2000 870 875 400 1660 150 125 100 65 50 50 40 40 2500 930 910 450 1710 150 125 125 65 50 50 40 40 3000 960 930 500 1760 200 150 125 80 65 65 40 40 4000 1060 950 550 1810 200 150 125 80 65 65 40 40 5000 1150 1025 600 1860 200 150 150 100 65 65 40 40 6000 1200 1100 650 1960 250 200 150 100 80 80 40 40 7000 1225 1200 700 2100 250 200 150 100 80 80 40 40 8000 1310 1225 750 2150 250 200 200 100 80 80 40 40 9000 1400 1280 800 2200 300 250 200 100 80 80 40 40 10000 1475 1320 900 2250 300 250 200 100 80 80 40 40 12000 1550 1400 900 2400 350 250 250 125 100 80 40 40 15000 1650 1500 1000 2550 350 300 250 125 100 80 40 40 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 25

WOOD RESIDUE, WOOD CHIP AND WOOD PELLET HEATING SYSTEMS BIOFLAMM Biomass is becoming more and more important economic factor as it enables energy independence and discontinuation of fossil fuel use which represent excessive impact on the environment. Due to the increasing prices of fossil fuels and financial country incentives for biomass equipment, investment into this equipment become very profitable in short-term. Our company has been producing boilers and biomass equipment for almost 30 years and has developed and still develops a wide range of products. Equipment is technologically adapted so it can be installed practically in every room, even in smaller boiler rooms which were planned for fuel oil boilers. The company strives for improvement of products, especially regarding the combustion technique, with solutions for combustion of chemically compromised wood residues and with the use of wide range of granulation and moisture. s are adapted also for burning wood pellets, thus allowing the use of biomass boilers even in cities, industrial facilities and other settlements. BIOFLAMM HEATING SYSTEMS MODEL: VE/SREB s are produced with the installed reactor with the step grate. They are produced by welding certified quality boiler sheet metal in accordance with DIN 4702 and 4751. Contraction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. The production process is controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Products are equipped with the CE 0036 marking. In the first draft, boilers with integrated burner are shielded with fireproof clay A 40 or A 60, depending on the fuel the device is planned for. Construction of the boiler allows to burn wood residue with humidity of up to 45%. s are equipped with a large combustion chamber and well dimensioned first and second draft for deposition of large particles of floating ash. They are equipped with two horizontal drafts and three vertical drafts routed through the pipe package. The inspection-cleaning doors are positioned on the side of the boiler (top, bottom) and on the back side, thus allowing easy access. All larger boilers are equipped with walkable platforms and railings, intended for cleaning and supply, and with entrance and exit ladders. They are also equipped with the automatic cleaning and ash removing system. The exterior of the boiler can be installed with automatic deashing which transfers the ash directly into the ash container. At the flue gas exhaust it is necessary to install a fan and a flue gas deduster, thus achieving dedusting of up to 80 mg/m3. Where the demands are very strict it is necessary to additionally install electric or fabric filters. Fabric filters enable cleaning of dust particles of up to 10 mg/m3. The entire device is controlled by the Lambdamatik micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. The standard scope of micro processing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is possible to supply customers with a control for remote regulation and inspection of the combustion process and for the control of peripheral units. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers or low pressure steam boilers with powers of up to 2 MW, temperatures 140 C and operating pressure 4.5 bars). model Power kw water quantity l height mm width mm lengt mm Safety flow Flow return Flue connection mm Weight kg V 3 116 570 1875 1138 1180 DN 50 DN 50 250 1500 V 4 174 980 1990 1310 1700 DN 50 DN 50 250 2100 V 5 291 1076 2003 1403 2040 DN 60 DN 80 300 2860 V 6 407 1985 2212 1538 2170 DN 65 DN 80 300 3715 V6 / 7 500 2300 2212 1538 2624 DN 65 DN 100 300 4150 V 7 600 2600 2214 1671 2624 DN 65 DN100 300 4570 V 8 750 2950 2442 2022 2785 DN 65 DN 100 400 6250 V 9 900 3580 2497 2052 3005 DN 65 DN 100 400 7770 V 10 1100 4210 2697 2102 3243 DN 80 DN 125 450 8900 V11 1250 4760 2833 2204 3570 DN 80 DN 150 500 10105 V12 1500 5230 2843 2360 3904 DN 80 DN 150 500 11623 V13 1750 6190 2839 2360 3945 DN 80 DN 150 500 12860 V14 2000 6560 2839 2360 4495 DN 100 DN 150 500 14500 V15 2200 7380 2839 2360 5045 DN 100 DN 150 500 16200 26 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

Model Heating power kw power kw Weight kg BIOFLAMM HEATING SYSTEMS MODEL: TRB/VA This heating device comprises the pre-fireplace reactor TRB and the VA boiler. The combination of these two components is used everywhere where the combustion conditions are difficult due to the higher humidity or due to the problematic fuel. Bioflamm multi draft VA boilers are used as heat exchangers and places for flue gas burn down. s are equipped with two horizontal drafts and three vertical drafts routed through the pipe packages. The inspection-cleaning doors are positioned on the side of the boiler (top, bottom) and on the back side, thus allowing easy access. In especially tough operating conditions boilers are shielded with quality fireproof clay in the first draft. Large dimensioned drafts and vertical pipe packages provide this heat exchanger with low temperature flue gases and enable high efficiency. All larger boilers are equipped with walkable platforms with railings intended for cleaning and supply and with entrance and exit ladder. They are produced by welding certified quality sheet metal in accordance with DIN 4702 and 4751. The construction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. The production process is controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Products are equipped with the CE 0036 marking. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers or low pressure steam boilers with powers of up to 6 MW, temperatures 140 C and operating pressure 4.5 bars). The automatic Bioflamm TRB pre-fireplaces with movable grates and automatic deashing enable the combustion of very problematic fuels. Reactors are constructed as a water-cooled pipe cage construction. The frame of the burner is shielded with quality fireproof clay A 40 or A 60, depending on the fuel the device is planned for. The quality movable transverse grates made of 24% chromed alloy ensure long service life and quality combustion on grates. Grates are installed next to each other, are simple, can be individually replaced, and form several movable grate layers. In case of extra humid, ash rich, or slag forming fuels, the Bioflamm degassing reactors with special air injection systems improve the combustion with their controlled combustion air fans. The primary air fan regulates the degassing process on the grate, whilst the secondary air fan enables combustion during the degassing of the formed flue gases. Separation from the fireplace and the boiler enables fast control in accordance with DIN 4751 Part 2. Reactors are produced in two construction versions; TRB N for humid fuels and TRB T for dry fuels. They are also equipped with the automatic cleaning and ash removing system. The exterior of the boiler can be installed with automatic deashing which transfers the ash into the ash container. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers with powers of up to 6 MW, temperatures 140 C and operating pressure 4.5 bars). In the past years, the company also developed an extra version of reactors marked TRB LK for connection of grain dryers or dryers of the sawdust accumulated during wood pellet production. Reactors are made of double-walled steel sheet frame where the air is directed into individual combustion zones. On the internal side, reactors are shielded with fireproof clay, whilst their external side is substantially insulated to prevent heat radiation into the environment. Grate movements and combustion air injection are similar to those of the basic version. The entire TRB/VA device is controlled by the Optimatika+ micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. The standard scope of micro processing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is possible to supply customers with a control for remote regulation and inspection of the combustion process and for the control of peripheral units. At the flue gas exhaust of the boiler it is necessary to install a flue gas deduster. Where the demands are very strict it is necessary to additionally install electric or fabric filters. Fabric filters enable cleaning of dust particles of up to 10 mg/m3. Water quantity l Flow return DN Lengt mm Width mm Height mm Center of the flame pipe mm Diameter of the flame pipe mm Height to the stoker mm TR-B 5N 343 291 4600 235 50 2776 1036 1721 964 580 989 TR-B 6N 479 407 5000 295 50 2786 1113 1741 999 640 1029 TR-B 7N 706 600 5230 307 50 2796 1190 1791 1034 710 1029 TR-B 8N 883 750 5500 318 65 2801 1421 1841 1044 784 1029 TR-B 9N 980 830 5700 350 65 2816 1498 1861 1079 800 1029 TR-B 10N 1295 1100 6000 381 65 3303 1421 1880 1109 860 1054 TR-B 11N 1470 1250 6400 412 65 3313 1575 1899 1139 880 1054 TR-B 12N 1765 1500 7900 432 65 3810 1498 1964 1149 900 1079 TR-B 13N 2059 1750 8100 475 80 3820 1575 2034 1199 1000 1079 TR-B 14N 2353 2000 8600 540 80 3830 1804 2109 1224 1050 1079 TR-B 15N 2588 2200 9250 625 80 3910 1960 2184 1249 1100 1079 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 27

BIOFLAMM HEATING SYSTEMS MODEL: TREB These heating devices were developed with the integration of transverse TRB reactors and VE boilers. This version is very good in coping with problems of combustion of all types of problematic fuels and allows installation in smaller boiler rooms. s allow the combustion of wood mass with humidity of up to 50% and wood mass with chemical substances which accumulate in the wood industry and could previously not be used as fuel due to the excessive emissions of harmful substances in flue gases. s are also appropriate for burning wood pellets and are equipped with a large combustion chamber and well dimensioned first and second draft for deposition of large particles of floating ash. They are equipped with two horizontal drafts and three vertical drafts routed through the pipe package. The external side of the boiler is equipped with a special system of channels for the supply of primary air under the grates. This feature improves the formation of wood gas as well as the combustion process. The inspection-cleaning doors are positioned on the side of the boiler (top, bottom) and on the back side, thus allowing easy access. All larger boilers are equipped with walkable platforms with railings intended for cleaning and supply, and with entrance and exit ladder. They are produced by welding certified quality sheet metal in accordance with DIN 4702 and 4751. The construction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. Production process is controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Products are equipped with the CE 0036 marking. The entire device is controlled by the Optimatika+ micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. The standard scope of micro processing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is possible to supply customers with a control for remote regulation and inspection of the combustion process and for the control of peripheral units. At the flue gas exhaust of the boiler it is necessary to install a flue gas deduster. Where the demands are very strict it is necessary to additionally install electric or fabric filters. Fabric filters enable cleaning of dust particles of up to 10 mg/m 3. s are factory shielded with fireproof clay A 60, which is resistant to high temperatures released during combustion. They are also equipped with a special system for the supply of primary and secondary air. The secondary air is conducted along special channels located in the body of the fireplace and directed with nozzles through the fireproof clay panelling into both drafts. Supply of the primary and secondary air is controlled via the continuously controlled fans. The entire device is controlled by the micro processing control via information received from the Lambda probe and temperature sensors. Model Heat power kw water quantity l height mm width mm lengt mm Safety flow Flow Flue connection mm TREB 5 291 1076 2403 1403 2040 DN 40 DN 80 300 3280 TREB 6 407 1985 2612 1538 2170 DN 50 DN 80 300 4110 TREB 7 600 2600 2612 1671 2624 DN 50 DN100 300 4970 TREB 8 750 2950 2614 2022 2785 DN 50 DN 100 400 6840 TREB 9 900 3580 2942 2052 3005 DN 50 DN 100 400 8410 TREB 10 1100 4210 2997 2102 3243 DN 65 DN 125 450 9530 TREB 11 1250 4760 3097 2204 3570 DN 65 DN 150 500 13080 TREB 12 1500 5230 3233 2360 3904 DN 65 DN 150 500 14020 TREB 13 1750 6190 3343 2360 3945 DN 65 DN 150 500 14810 TREB 14 2000 656 0 3339 2360 4495 DN 65 DN 150 500 16550 TREB 15 2200 7380 3339 2360 5045 DN 80 DN 150 500 18230 Weight kg 28 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

BIOFLAMM HEATING SYSTEMS MODEL: SRF-RK These boilers are appropriate for burning relatively dry wood chips with humidity of up to W 45, and wood pellets. They include a fireplace and a heat exchanger. Fireplaces with the movable step grate represent the basic part of these boilers. Fireplaces are shielded with quality fireproof clay. Construction of the boiler enables burning relatively clean wood residue and wood pellets. s are equipped with a large combustion chamber which enables good combustion. The front side of the fireplace is equipped with primary and secondary air fans. The air is conducted into the combustion process along a special system of channels and air injection nozzles, thus achieving swirling of flue gases and further increasing the combustion. fireplaces are equipped with horizontal heat exchangers. Three draft heat exchangers are equipped with channels for first inversion of hot flue gases, whilst the other two inversions take place through pipe packages. Large dimensioned drafts horizontal pipe packages provide the boiler with low temperature flue gases and enable high efficiency. They are produced by welding certified quality boiler sheet metal in accordance with DIN 4702 and 4751. Contraction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. The production process is controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Additional quality control is provided by the company TÜV Sava Ljubljana and other institutions taking care for product quality control. s are equipped with thermal protection devices for protection against overheating. The horizontal heat exchanger pipes are cleaned pneumatically or in accordance with the special programme. The inspection-cleaning doors are positioned on the front of the boiler (top, bottom), thus allowing easy access for cleaning of horizontal drafts. They are also equipped with the automatic cleaning and ash removing system. The exterior of the boiler can be installed with automatic deashing which transfers the ash directly into the ash container. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers or steam boilers with powers of up to 10 MW, temperatures 160 C and operating pressure 10 bars). s are shielded with fireproof clay A 40 or A 60, depending on the used fuel and operating conditions. In case the boilers burn dry fuel or wood pellets, they are factory shielded with fireproof clay A 60, which is resistant to high temperatures. They are also equipped with a special system for the supply of primary and secondary air. The secondary air is conducted along special channels located in the body of the fireplace and directed with nozzles through the fireproof clay panelling into both drafts. Supply of the primary and secondary air is controlled via the continuously controlled fans. The entire device is controlled by the micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. The standard scope of micro processing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is possible to supply customers with a control for remote regulation and inspection of the combustion process and for the control of peripheral units. At the flue gas exhaust of the boiler it is necessary to install a flue gas deduster. Where the demands are very strict it is necessary to additionaly install electric or fabric filters. Fabric filters enable cleaning of dust particles of up to 10 mg/m3. Smaller boilers are delivered welded as a whole, whilst, larger boilers come in two parts which are later assembled together in your boiler room. Assembly in the boiler room is especially welcome in case of low passages where the transport into the boiler room is less favourable. Type Bioflamm TRF-RK Power (flame) kw Useful boiler power kw Weight kg water quantity l Flow Return DN Safety flow DN Lengt mm Width mm Height mm SRF RK 300 343 300 5950 720 80 40 2976 1236 2921 SRF RK 400 479 400 6610 1330 80 40 3286 1313 3141 SRF RK 500 595 500 6980 1560 80 40 3296 1490 3291 SRF RK 600 706 600 7220 1980 100 50 3583 1500 3457 SRF RK 750 883 750 7930 2275 100 50 3583 1590 3470 SRF RK 860 980 850 8490 2390 100 50 3816 1698 3861 SRF RK 1000 1295 1100 9930 2820 100 50 4203 1821 3980 SRF RK 1250 1470 1250 10410 3190 125 65 4313 1975 4099 SRF RK 1500 1765 1500 11920 3510 150 65 4810 2098 4164 SRF RK 1750 2059 1750 12150 4150 150 65 5220 2175 4334 SRF RK 2000 2353 2000 14680 4380 150 80 5330 2204 4409 SRF RK 2200 2588 2200 16250 4940 150 80 5410 2460 4584 SRF RK 3000 3478 3000 16250 4940 200 80 5410 2460 4584 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 29

BIOFLAMM KURILNI SISTEMI MODEL: TRF-RK These boilers are appropriate for use where the biomass humidity cannot be controlled or where the humidity cannot be dried out and therefore remains very high. In the first and second draft, boilers are shielded with quality fireproof clay. The quality movable transverse grates made of 24% chromed alloy ensure long service life and quality combustion on grates. Construction allows to burn inferior and problematic humid wood residues which could previously not be used as fuel due to the excessive emissions of harmful substances in flue gases. s are equipped with a large combustion chamber with the first inversion of hot flue gases over the fuel where the first phase of fuel drying begins. The large quantity of fireproof clay radiates the temperature on the fuel which moves along the grate, thus drying it additionally. The front side of the fireplace is equipped with primary and secondary air fans. The air is conducted into the combustion process along a special system of channels and air injection nozzles, thus achieving swirling of flue gases and further increasing the combustion. The well-dimensioned second draft serves also for deposition of large particles of floating ash. fireplaces are equipped with horizontal heat exchangers. Three draft heat exchangers are equipped with channels for first inversion of hot flue gases, whilst the other two inversions take place through pipe packages. Large dimensioned drafts horizontal pipe packages provide the boiler with low temperature flue gases and high efficiency. s are produced by welding certified quality boiler sheet metal in accordance with DIN 4702 and 4751. The construction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. The production process is constantly controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Additional quality control is provided by the company TÜV Sava Ljubljana and other institutions taking care for product quality control. s are equipped with thermal protection devices for protection against overheating. The horizontal heat exchanger pipes are cleaned pneumatically or in accordance with the special programme. The inspection-cleaning doors are positioned on the front of the boiler (top, bottom), thus allowing easy access for cleaning of horizontal drafts. They are also equipped with the automatic cleaning and ash removing system. The exterior of the boiler can be installed with automatic deashing which transfers the ash directly into the ash container. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers or steam boilers with powers of up to 10 MW, temperatures 160 C and operating pressure 10 bars). s are factory shielded with fireproof clay A 60, which is resistant to high temperatures. They are also equipped with a special system for the supply of primary and secondary air. The secondary air is conducted along special channels located in the body of the fireplace and directed with nozzles through the fireproof clay panelling into both drafts. Supply of the primary and secondary air is controlled via the continuously controlled fans. The entire device is controlled by the micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. Type Power Useful Weight water Flow Safety Lengt Width Height Standard scope of microprocessing control delivery includes Bioflamm (flame) boiler power quantity Return flow the system for calling of 6 telephone numbers in case of TRF-RK kw kw kg l DN DN mm mm mm standstill of any component of the device. With additional TRF-RK 300 343 300 6600 720 80 40 2776 1036 2820 payment it is possible to supply customers with a control TRF-RK 400 479 400 7500 1330 80 40 2786 1113 2820 for remote regulation and inspection of the combustion TRF-RK 500 595 500 8230 1560 80 40 2796 1190 3080 system and for the control of peripheral units. At the flue TRF-RK 600 706 600 9500 1980 100 50 2801 1421 3290 gas exhaust of the boiler it is necessary to install a flue gas TRF-RK 750 880 750 10600 2430 100 50 2816 1498 3220 deduster. TRF-RK 860 987 850 10600 2390 100 50 2816 1498 3220 Where the demands are very strict it is necessary to TRF-RK 1000 1295 1000 11400 2820 100 50 3303 1421 3330 additionally install electric or fabric filters. Fabric TRF-RK 1250 1470 1250 13250 3190 125 65 3313 1575 3410 filters enable cleaning of dust particles of up to TRF-RK 1500 1765 1500 16300 3510 150 65 3810 1498 3490 10 mg/m 3. Smaller boilers are delivered welded as a whole, TRF-RK 1750 2059 1750 17900 4150 150 65 3820 1575 3520 whilst larger boilers come in two parts which are later TRF-RK 2000 2353 2000 19500 4380 150 80 3830 1804 3590 assembled together in your boiler room. Assembly in the TRF-RK 2200 2588 2200 22250 4940 150 80 3910 1960 3880 boiler room is especially welcome in case of low passages TRF-RK 3000 3478 3000 27990 5720 200 80 3910 2250 4290 where the transport of the boiler is less favourable. 30 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

DEVICE CONTROL Controls with the Lambda probe Lambdamatika and Optimatika+ are installed in Rital cabinets which include all control elements for the entire system, continuous motor drives, protection of drive units, and the device for calling of 6 telephone numbers. On special order they can also be installed with modems for connection with the remote control. The cabinet is equipped with the main switch (depending on the supply power of electric motors) and the emergency switch. Doors of the cabinet are equipped with the microprocessor with a display and a keyboard for direct access into the combustion parameter setting program. Use of the program and the input of desired data is simple as the program allows scrolling with cursor keys and includes simple commands. The programme is made as a multi-level programme device operator level and repair or fine-tune expert level. VISUALIZATION The communication package for remote control of data and for the visualization of operation is used for control when the operator is out of the boiler room. The connection is established with the help of the modem and internet, or directly via the cable in case of small distances. In case of the cable connection, the visualization works trouble-free for 24 h, but demands an amplifier in case of distances greater than 200 m. Long-term connection via your telephone will cause disturbances during monitoring of current values due to the signal strength fluctuation. Significant data about device operation and reports of disturbances can be followed on the PC display. This way enables the operator-supervisor the access to all required data, which is why he can quickly react in cases of device malfunctioning. On the basis of these data, the supervisor makes corrective measures and adapts the operation to desired parameters. If the supervisor is unable to repair the malfunctioning he must immediately contact the manufacturer's service team which will take care for it with no major problems. With the permission of the investor, the manufacturer's service team can enter into the communication system. The visualization allows access to different levels of operation, depending on the data to be checked. All levels enable formation of excel charts and analyses of operation in individual time periods. Because this is a complex heating device, we recommend the operator to plan adequate maintenance interventions on the basis of number of hours of operation. COMPANY PRESENTATION OUR 150 YEARS Company WVterm from Maribor continues the TVT Boris Kidrič company's tradition in the field of boiler production. The beginning of industrial production reaches back in 1863 when the railway carriage and steam locomotive overhaul facilities were constructed. In 1970 the TVT Boris Kidrič, proizvodnja tirnih in cestnih vozil company signed a contract with the German STADLER company. Later, TVT became the biggest producer of boilers in the former Yugoslavia. Unfortunately, this big company could not avoid the crisis which appeared after the break-up of Yugoslavia. In 1995 an ownership transformation occurred and a new company WVterm was founded. During the past years, WVterm proved to be a vital export oriented company. The changed approach to work enabled better conditions in all fields of operation. The operation economics provides the company with a favourable business partner position. The company experienced rapid growth during the past years and today employs approx. 80 workers instead of the original 27. Due to the local conditions, export orientation was compulsory and today represents over 60% of all production. Our biggest partners come from the EU market. Besides the EU market the company is also present in the markets of the former Yugoslavia where the TAM STADLER trademark is still appreciated. Our perspective is built on experience upgraded with hard development work and with the aim to develop good products interesting for the market. With the internal and external potentials we significantly renewed and expanded our production programme. Efficiencies as well as low flue gas emissions and design of our products are now at the same level as the European competition. The conformity of products is guaranteed with the company s TÜV certificates which represent an integral part of documentation. One of the founding aims of the market appearance is to renew the old trademark that is to establish a positive contact with the market. We strive to restore the good name of the STADLER TVT trademark with hard work and quality production. Use of the trademark is protected both at home and abroad with number Z-9670961. Besides this trademark we are also present in the wood biomass market with Bioflamm and HDG Bavaria trademarks. The company provides HDG boilers in Slovenia and other countries of the former Yugoslavia. Company's production programme is very wide and with its Made in Slovenija products covers almost all areas of hot water boiler production. In the last years, the company increasingly invested in new technologies and has already caught up with technical development of its European competitors, thus keeping its competitiveness in the EU. During the last years, the welding technology was modernised with new pulse welding machines and robot welding of boilers and components. Preparation of boiler parts is based on top-class laser cutting of sheet metal and CNC technology for sheet metal and pipe forming. This technology helped us to achieve the production and productivity which is comparable with European competitors. WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 31

Valvasorjeva 73, 2000 Maribor Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67 Industrial store: Tel.: +386 2 429 28 20, Fax: +386 2 420 02 79 www.wvterm.si wvterm@wvterm.si art a design - Kramberger & Uran

WV term d.o.o. E-mail Adress: wvterm@wvterm.si Predstavitev: www.wvterm.si STADLER TVT TRADE MARKS: STADLER TVT Bioflamm COMPANY PRESENTATION REFERENCES 1 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT PRESENTATION OUR 150 YEARS Company WVterm from Maribor continues the TVT Boris Kidrič company's tradition in the field of boiler production. The beginning of industrial production reaches back in 1863 when the railway carriage and steam locomotive overhaul facilities were constructed. In 1970 the TVT Boris Kidrič, proizvodnja tirnih in cestnih vozil company signed a contract with the German STADLER company. Later, TVT became the biggest producer of boilers in the former Yugoslavia. Unfortunately, this big company could not avoid the crisis which appeared after the break-up of Yugoslavia. In 1995 an ownership transformation occurred and a new company WVterm was founded. During the past years, WVterm proved to be a vital export oriented company. The changed approach to work enabled better conditions in all fields of operation. The operation economics provides the company with a favourable business partner position. The company experienced rapid growth during the past years and today employs approx. 80 workers instead of the original 27. Due to the local conditions, export orientation was compulsory and today represents over 60% of all production. Our biggest partners come from the EU market. Besides the EU market the company is also present in the markets of the former Yugoslavia where the TAM STADLER trademark is still appreciated. Our perspective is built on experience upgraded with hard development work and with the aim to develop good products interesting for the market. With the internal and external potentials we significantly renewed and expanded our production programme. Efficiencies as well as low flue gas emissions and design of our products are now at the same level as the European competition. The conformity of products is guaranteed with the company s TÜV certificates which represent an integral part of documentation. One of the founding aims of the market appearance is to renew the old trademark that is to establish a positive contact with the market. We strive to restore the good name of the STADLER TVT trademark with hard work and quality production. Use of the trademark is protected both at home and abroad with number Z-9670961. Besides this trademark we are also present in the wood biomass market with Bioflamm and HDG Bavaria trademarks. The company provides HDG boilers in Slovenia and other countries of the former Yugoslavia. Company's production programme is very wide and with its Made in Slovenija products covers almost all areas of hot water boiler production. In the last years, the company increasingly invested in new technologies and has already caught up with technical development of its European competitors, thus keeping its competitiveness in the EU. During the last years, the welding technology was modernised with new pulse welding machines and robot welding of boilers and components. Preparation of boiler parts is based on topclass laser cutting of sheet metal and CNC technology for sheet metal and pipe forming. This technology helped us to achieve the production and productivity which is comparable with European competitors. Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 2

WV term d.o.o. COMPANY IN PICTURES STADLER TVT COMPANY DATA Value Yearly turnover 4,8 mio Number of employees 68 Export 43% IExport in EU 38% Domestic market 57% Turnover with products 81% Turnover with services 19% Employees with high education 8 Employees with middle education 20 Qualified workers 28 Trained workers 12 Technology and development 7 Research and development group 3 ISO 9001 modul B and D Service for quality Own boiler testing room yes yes up to 50 kw Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 3

WV term d.o.o. STADLER TVT MASCHINERY EQUIPMENT EQUIPMENT/MASCHINERY Laser cutting maschine 3000 V Laser cutting maschine 3000 V Plasma cutting maschine 2 x 2000 V Welding robot VALUE table 2 x 4 m table 1,5 x 3 m table 2 x 8 m 2 x table 0,7 ton Welding automat 2 CNC bending maschine CNC bending maschine CNC curving maschine 250 ton 200 ton d=8 mm Curving maschine d=14 mm CNC maschine for cutting tubes and sticks 400 mm Maschines for forming the tubes 3 Hidraulic bending maschine Shears for cuttin up to thickness 250 ton 12 mm Boring maschine up to 100 mm 4 Fres maschine 1 Lathmaschine 400 mm L=3 m 2 Puls welding appliance 10 Enamel finish 1 Crane up to 30 tons 2 Crane up to 5 tons 4 Forkmaschineup to 4 tons 4 Trucks up to 5 tons 2 Service vehicles 5 Production surface 4.500 m 2 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 4

WV term REFERENCES d.o.o. STADLER TVT WVterm has s TŰV certificate AD- Merkblatt HP 0 and certificate TRD 201, tis helps the company to produce tipicaly certified boilers and vessels under higher pressure. The company has become the certificate in accordance to Standard ISO 9001 modul B and modul D, which emphasizes the qualifications of the company for the production of boilers. In accordance with the slovene legislation WVterm has the certificate that it is qualified for boiler welding and production of high pressure vessels. Tha Company ha salso golden sign for the product quality SQ. We have many patents and trade marks protected at the Bureau of industrial property. We produce over 3.000 pieces of boilers yearly, the capacity varries from 12 kw to 6.000 kw, among them there are over 100 pieces of boilers with capacity from 200 kw to 6.000 kw. Lately we encrease the production of boilers for biomass. We V zadnjem času se močneje širi proizvodnja kotlov na biomaso, kar velja tudi za slovenski trg. Through our domestic partner in Germany we cover the markets in all European countries. Our biggest devices from 3 MV up to 6 MV work in Germany, Netherlands, Italy and Russia. The greatest meaning in our economical position has our export, that is why we strive after high business and high quality. Our Sale to former Yugoslav markets is higher from year to year. The trade mark STADLER is on this markets still appreciated. Graf 1 REALIZACIJA PO DRŽAVAH SLOVENIJA 39% NEMČIJA 42% NEMČIJA AVSTRIJA BOSNA SRBIJA HRVAŠKA 0% SRBIJA 2% BOSNA 4% AVSTRIJA 13% HRVAŠKA SLOVENIJA The company exports over 60 % of its yearly production, 55 % is exported to european Union. Special Refference is Projekting and control of Instalation in Hospital in Jakutsk Russia, area over 50.000 m 2. Projekt was made throug Biro 71 Ljubljana in the Yaer 1995. Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 5

WV term d.o.o. REFERENCE LIST OF DEVICES ON BIOMASS FUEL STADLER TVT Type of device Fuel Kapacity in kw Buyer State SR-EB 4 / V4 E pellets 200 PLANINSKI MUZEJ MOJSTRANA SLOVENIJA SR-EB 4 / V4 E wood chip 200 ŽG LJUBLJANA SLOVENIJA SR-EB 5 / V5 E wood chip 300 DETA SLOVENIJA SR-EB 5 / V5 E wood chip 300 TRGOCEV SLOVENIJA SD 5/FLUID Eragon dry sawdust 300 PABLES SLOVENIJA SR-EB 6 / V6 E wood chip 400 KAGER HIŠE SLOVENIJA SR-EB 6 / V6 E pellets 400 DIJAŠKI DOM DRAVA SLOVENIJA SR-EB 6 / V6 E wood chip 400 ŠPORTNI CENTER DRAŠ SLOVENIJA TR-EB 6 / V6 E wood chip 400 COMTRON IN SLOVENIJA TR-EB 6 / V6 E wood chip 400 OŠ PUCONCI SLOVENIJA SR-EB 7 / V7 E wood chip 500 SIRIUS SLOVENIJA VA 7/ FLUID Eragon dry sawdust 600 MIZARSTVO MAKOVEC SLOVENIJA SR-EB 6 / V6 E parni 0,5 bar wood chip 600 / 800 kg pare/ h TOPP SLOVENIJA SR-EB 8 / V8 A wood chip 750 PRELOG SLOVENIJA SR-B8 SW / V8-E wood chip 750 ECOM RUŠE SLOVENIJA TR B8 (N) / V8 A wood chip 750 SOBERNHEIM NEMČIJA SR-EB 8 / V8 E peleti 750 VITEZ BiH SR-EB 8 / V8 A peleti 2 x 750 BRČKO BiH SRF-RKP 750 parni kotel 4,0 bar wood chip 750 / 960 kg pare/ h SIRARNA BOHINJ SLOVENIJA VA 10/ FLUID Eragon dry sawdust 1.100 JOŠT HOTEL SLOVENIJA SRF-RK 860 wood chip 860 KEMIJSKA ŠOLA RUŠE SLOVENIJA TRF-RK 1100 wood chip 1.100 OSL REWE NEMČIJA TRF-RK 1100; SRF-RK 520 wood chip 1.100+520 WVterm SLOVENIJA TR EB 10 / V10 E wood chip 1.100 SESLACH NEMČIJA VA 11/ FLUID Eragon dry sawdust 1.250 CELES SLOVENIJA VA 11/ FLUID Eragon dry sawdust 1.250 RIKO HIŠE SLOVENIJA TREB 11,/ SR-EB 7 / V7 E Mitraka wood chip 1.250+600 AHA EMI SLOVENIJA SR-B11 SW / V11 A 6 bar wood chip 1.250 KREUTH NEMČIJA TRB 11 / V11 A wood chip 1.250 GG NOVO MESTO SLOVENIJA TRF-RK 1250 wood chip 1.250 PROFILES SLOVENIJA SR-EB 11 / V11 E wood chip 1.250 DELNICE HRVAŠKA SR-EB 12 / V12 E wood chip 1.500 SCHLESWAG AVSTRIJA SR-EB 12 / V12 E wood chip 1.500 REMA / TORKIN BELGIJA TR B12 (N) / V 12A wood chip 1.500 RAALTE NIZOZEMSKA TRF-RK 1500 wood chip 1.500 KOZJE daljinsko ogrevanje SLOVENIJA SR-EB 13 / V13 E wood chip 1.750 NAHOMA ROHA FINSKA SR-EB 13 / V13 E wood chip 1.750 MILANO ITALIJA SR-EB 13 / V13 E wood chip 1.750 REFRONTOLO ITALIJA SR-EB 13 / V13 E wood chip 1.750 PIOBESI TORINESE ITALIJA SR-EB 13/ V13 E wood chip 1.750 ETHON VEL. BRITANIJA TREB 13 Eragon 4,5 bar wood chip 1.600 KOPITARNA SLOVENIJA VA 13/ FLUID Eragon 4,5 bar dry sawdust 1.600 TUS KOSI SLOVENIJA TRB 14 / V14 A wood chip 2.000 EFFETTI ITALIJA TRB 14 / V14 A wood chip 2.000 GORENJE MARLES SLOVENIJA TRF-RK 2000 Mitraka wood chip 2.200 TERME OLIMJA SLOVENIJA TRF-RKP 2000 parni kotel 6 bar wood chip 2.000/3000 kg pare/ h VITIVA SLOVENIJA TRB LK 15 wood chip 2.200 SUŠILNICA BIOMASE TRGOVIR BiH TRB 15 / V 15A wood chip 2.250 ILMES SLOVENIJA TRB 15/V 15A wood chip 2.588 ČARDAK daljinsko ogrevanje SLOVENIJA TRB 15/V 15A wood chip 2.588 WARENDORF NEMČIJA TRB 30 /V 30A wood chip 3.000 NIEUWEWEG NEMČIJA TRB /V 30A wood chip 3.000 TAMAI DI BRUNERA ITALIJA TRB 35/V 35A wood chip 3.500 BATTAGLIA ITALIJA TR EB 15 + TR EB 12 wood chip 2.200+1.500 Bolnica MINDEN NEMČIJA TRB 15/V 15+ V 11/TRB 11 wood chip 2.588+1.500 INLES RIBNICA SLOVENIJA TRB 25 wood chip 2.500 SUŠILNICA BIOMASE TRGOVIR BiH TRB 30 / V30 A wood chip 3.000 FIS VITEZ BiH TRB 30 wood chip 3.000 GRAFENEK SUŠILNICA ŽIT AVSTRIJA TRB LK 30 wood chip 2x3.000 OZL SUŠILNICA ŽIT UKRAJINA TRB LK 30 wood chip 3.000 SUŠILNICA ŽIT SLOVENIJA TRB 45 wood chip 4.500 MENEGOLO ITALIJA TRB 60 / V 60 wood chip 6.000 BAUTEX RUSIJA Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 6

WV term d.o.o. STADLER TVT COMPLIENCE WITH THE REGULATIONS FOR BIOMASS BOIKERS Stack gas emissions The design of the boiler control "Bioflamm-Lambdamatika or Optimatik +" by the lambda probe and multiciklon ensure that the device will operate with high efficiency, emission of flue gases will be in accordance with the requirements (Official Gazette 34/07, Official Gazette of RS 73/94, 105 / 00, 84/02 and amedments of the Official Gazette of RS 51/98). emitted substance MEV v mg/m3 pri 11% O2 vol. total dust 1 Heat loss from the flue gases 175 Total dust 20 60 v odvisnosti od moči kotla carbon monoxide (CO) at rated power 150 Nitrogen oxides (NOx) expressed as NO2 250 Sulphur oxides (SOx), expressed as SO2 1000 Organic compounds expressed as total organic carbon 10 (TOC) Konstruktional implementation Safety Technical derivation of Bioflamm combustion plant according to TRD 414 section 1.6 and 1.7: Devices that are licensed and are operating from a TÜV-tested, are equipped with guards metering of electrical drives with self-control, safety buffer. For closed heating installations according to DIN 4751 and TRD 702 device meets the prescribed implementation of district heating system, which has proven parts. The two-step temperature controller and Safety temperature limiter according to DIN 3440 The safety valve according to TRD 721 and sensor min. and max. pressure Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 7

WV term d.o.o. STADLER TVT STUDENT HOME DRAVA MARIBOR 8 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT STUDENT HOME DRAVA MARIBOR Technical Data Type of device SREB6/VE6 Kapacity of boiler 400 kw Type of fuel pellets Fuel moisture max. 12% Emission of dust in smoke gases 60 mg/m 3 Transport of the fuel Worm convayor Pellets silo 90 m 3 Consumption of fuel out of the tank with movable base Hidravlic cylinder 160 mm Hot water acumulator 2x3000 l Year of installation 2012 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 9

WV term d.o.o. STADLER TVT BOILER HOUSE GORENJE MARLES Maribor 10 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT BOILER HOUSE GORENJE MARLES Maribor Technical Data Type of device TRB14/VA14 Kapacity of boiler 2.000 kw Type of fuel Wood chips Fuel moisture max. 45 % Chip size G 50 Emission of dust in smoke gases 80 mg/m 3 Transport of the fuel conveyor The fuel storage room 180 m 3 Consumption of fuel out of the tank with movable base Hidravlic cylinder 2x200 mm Hot water acumulator 30.000 l Year of installation 2009 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 11

WV term d.o.o. ALP MUSEUM MOJSTRANA STADLER TVT 12 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT ALP MUSEUM MOJSTRANA Technical Data Type of device SREB4/VE4 Kapacity of boiler 200 kw Type of fuel pellets Fuel moisture max. 12% Emission of dust in smoke gases 60 mg/m 3 Transport of the fuel z polži The fuel storage room 50m 3 Consumption of fuel out of the tank spring cover Hidravlic cylinder Hot water acumulator 2x3000 l Year of installation 2010 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 13

WV term d.o.o. DISTRICT HEATING ČRNOMELJ - ČARDAK STADLER TVT 14 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT DISTRICT HEATING ČRNOMELJ - ČARDAK Technical data Type of device TRB15/VA15 Kapacity of the boiler 2.200 kw Type of fuel Wood chips Fuel moisture max. 45% Chip size G 50 Emission of dust in smoke gases 80 mg/m 3 Transport of the fuel conveyor The fuel storage room 250 m 3 Consumption of fuel out of the tank with movable base Hidravlic cylinder Hot water acumulator 4 x 200 mm 40.000 l Year of installation 2007 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 15

WV term d.o.o. STADLER TVT STEAM BOILER HOUSE VITIVA MARKOVCI 16 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT STEAM BOILER HOUSE VITIVA MARKOVCI Techical data Type of device TRF RKP 2000 Kapacity of boiler 2.200 kw Kapacity of steam 3,500 kg/h Steam operating pressure 8 bar Emission of dust in smoke gases 20 mg/m 3 Fuel type Wood chips Fuel moisture max. 45% Chip size G 50 Transportation of fuel conveyor The fuel storage room 2x250 m 3 Consumption of fuel out of the tank with movable base Hidraulic cylinder 2 x 3 x 200 mm Year of installation 2012 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 17

WV term d.o.o. STADLER TVT CEREAL DRYING HOUSE ŠKAPER VANEČA 18 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT CEREAL DRYING HOUSE VANEČA Technical data Type of the device TRB LK 30 Kapacity of boiler 1.980 kw Emission of dust in smoke gases 80 mg/m 3 Kapacity of drying 15 ton/h Temperature of drying 120 C Vertikal heat exchanger 1.980 kw Air flow through the exchanger 65.000 m 3 /h Type of fuel Wooden chips Flue moisture max. 45% Chip size G 50 Transportation of the fuel conveyor The fuel storage room 190 m 3 Consumption of fuel out of the tank Hidraulic cylinder Reserve fuel Movable base 3 x 200 mm Natural gas Year of installation 2013 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 19

WV term d.o.o. STADLER TVT PRIMARY SCHOOL PUCONCI 20 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT PRIMARY SCHOOL PUCONCI Technical data Type of the device TRB6/V6E Kapacity of the boiler 400 kw Fuel type Wooden chips Fuel moisture max. 45% Chip size G 30 Emission of dust in smoke gases 80 mg/m 3 Transportation of fuel conveyor The fuel storage room 120 m 3 Consumption of fuel out of the tank Movable base Hidraulic cylinder 2 x 200 mm Year of installation 2013 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 21

WV term d.o.o. BOILER HOUSE OLIMIA SPA STADLER TVT 22 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT BOILER HOUSE OLIMIA SPA Tehnični podatki Type of the device TRF RK 2000 Kapacity of the boiler 2.000 kw Fuel type Wooden chips Fuel moisture max. 60% Chip size G 50 Emission of dust in smoke gases 20 mg/m 3 Transportation of fuel conveyor The fuel storage room 300 m 3 Consumption of fuel out of the tank Movable base Hidraulic cylinder Warm water acumulator 3 x 200 mm 50.000 l Year of the instalation 2011 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 23

WV term d.o.o. STADLER TVT DISTRICT HEATING KOZJE 24 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT DISTRICT HEATING KOZJE Technical data Type of the device TRF RK 1500 Kapacity of the boiler 1.500 kw Fuel type Wooden chips Fuel moisture max. 60% Chip size G 50 Emission of dust in smoke gases 20 mg/m 3 Transportation of fuel conveyor The fuel storage room 350 m 3 Consumption of fuel out of the tank Movable base Hidraulic cylinder Warm water acumulator 3 x 200 mm 50.000 l Year of the instalation 2013 25 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT BOILER HOUSE FIS VITEZ BOSNA 26 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT BOILER HOUSE FIS VITEZ BOSNA Technical data Type of the device TRB 30/VA 30 Kapacity of the boiler 3.000 kw Fuel type lesni sekanci Fuel moisture max. 80% Chip size G 50 Emission of dust in smoke gases 80 mg/m 3 Transportation of fuel transportni trak The fuel storage room 450 m 3 Consumption of fuel out of the tank pomična dna Hidraulic cylinder Warm water acumulator 3 x 200 mm Year of the instalation 2011 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 27

WV term d.o.o. STADLER TVT BOILER HOUSE FIS BRČKO BOSNA 28 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT BOILER HOUSE FIS BRČKO BOSNA Technical data Type of the device SREB 8/VE8 Kapacity of the boiler 2x750 kw Fuel type pellets Fuel moisture max. 10% Chip size Emission of dust in smoke gases 80 mg/m 3 Transportation of fuel conveyor The fuel storage room 250 m 3 Consumption of fuel out of the tank Movable base Hidraulic cylinder Warm water acumulator 2 x 200 mm Year of the instalation 2010 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 29

WV term d.o.o. STADLER TVT BOILER HOUSE GG NOVO MESTO 30 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT BOILER HOUSE GG NOVO MESTO Technical data Type of the device TRB 12/VA 12 Kapacity of the boiler 1.250 kw Fuel type lesni sekanci Fuel moisture max. 80% Chip size G 50 Emission of dust in smoke gases 80 mg/m 3 Transportation of fuel transportni trak The fuel storage room 450 m 3 Consumption of fuel out of the tank pomična dna Hidraulic cylinder Warm water acumulator 3 x 200 mm 30.000 l Year of the instalation 2009 31 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT GRAMMAR SCHOOL RUŠE 32 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT GRAMMAR SCHOOL RUŠE Technical data Type of the device STRF RK 860 Kapacity of the boiler 860 kw Fuel type Wooden chips Fuel moisture max. 40% Chip size G 50 Emission of dust in smoke gases 60 mg/m 3 Transportation of fuel transportni polz The fuel storage room 210 m 3 Consumption of fuel out of the tank krožno zajemalo Hidraulic cylinder Warm water acumulator 10.000 l Year of the instalation 2013 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 33

WV term d.o.o. STADLER TVT AHA EMMI SLOVENSKA BISTRICA 34 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT AHA EMMI SLOVENSKA BISTRICA Technical data Type of the device Kapacity of the boiler TREB 11+ SREB /VE8 1.250+600 kw Fuel type Wooden chips Fuel moisture max. 45% Chip size G 50 Emission of dust in smoke gases 80 mg/m 3 Transportation of fuel conveyor The fuel storage room 310 m 3 Consumption of fuel out of the tank Movable base Hidraulic cylinder Warm water acumulator 3 x 200 mm 30.000 l Year of the instalation 2009 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 35

WV term d.o.o. STADLER TVT PRIMARY SCHOOL DELNICE CROATIA 36 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT PRIMARY SCHOOL DELNICE CROATIA Technical data Type of the device Kapacity of the boiler SREB 12/VE12 1.250 kw Fuel type pellets Fuel moisture max. 10% Chip size G 50 Emission of dust in smoke gases 60 mg/m 3 Transportation of fuel transportni polz The fuel storage room 190 m 3 Consumption of fuel out of the tank Movable base Hidraulic cylinder Warm water acumulator 2 x 200 mm 10.000 l Year of the instalation 2012 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 37

WV term d.o.o. STADLER TVT BOILER HOUSE PROFILES RAZDRTO 38 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279

WV term d.o.o. STADLER TVT BOILER HOUSE PROFILES RAZDRTO Technical data Type of the device TRF RK 1250 Kapacity of the boiler 1.250 kw Fuel type Wood chips Fuel moisture max. 60% Chip size G 50 Emission of dust in smoke gases 80 mg/m 3 Transportation of fuel auger The fuel storage room 280 m 3 Consumption of fuel out of the tank Movable base Hidraulic cylinder Warm water acumulator 3 x 200 mm Year of the instalation 2012 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 39

WV term d.o.o. STADLER TVT BOILER HOUSE PLANINA KRANJ Technical data Type of the device Kapacity of the boiler Hot warter ZV 10.000+7.000 kw Fuel type zemeljski plin Temperature regime 130/60 C CNS for system Attached to cogeneration Year of installation 2012 Valvasorjeva 73, 2000 Maribor, tel.:(386)02/4292-810, fax:(386) 02/4202-167, Industrijska prodajalna: tel.:(386)02/4292-820 fax:(386)02/4200-279 40

FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER TR STADLER TR firewood hot water central heating boilers provide comfortable and energy saving heating. Such heating is enabled with integration of the new innovative technology in the field of control and modern production technology. s are constructed for burning all types of wood and reach efficiencies of over 91%. Constant growth of fossil fuel prices and the increased care for the environment make this boiler even more important. By using different types of wood, even of different humidity, these boilers allow you to reach perfect combustion conditions. Emitted flue gases are harmless to the natural balance. You should load the boiler with ½ m long firewood as close together as possible, thus reaching uniform fuel structure and stable combustion conditions. Single load should be enough for several hours of operation. Fireplace volume equals to 150 l and can be loaded with up to 50kg of hardwood logs. Connection to the power supply is very simple, as the boiler includes already prepared wiring with plug equipped cables. By purchasing our boiler, you meet all of the requirements to obtain your government's subsidy. Construction of the boiler incorporated the modern degassing combustion technology. The flame is vertically directed through the burner nozzle with the help of the controlled injection of the primary and secondary air. When the flame enters the combustion chamber, it swirls and in touch with the red-hot combustion chamber causes the remaining not-combusted wood gases to burn at temperatures of approx. 1000 C. The control regulates the operation of the primary and secondary air step motors, thus supplying the combustion process with regulated quantities of air which enable the best combustion. The large panel shielded loading place protects the boiler from accumulation of tar and ensures long service life of the boiler. s can be loaded with firewood of up to 56 cm in length. The burner nozzle is made of chrome alloy which also significantly prolongs the service life of the boiler. 2 The fireproof clay combustion chamber is upgraded with the bottom made of high-temperature resistant concrete which guarantees complete combustion of wood gases. s are equipped with the Lambda probe, temperature sensor and continuously controlled electric motor of the fan. WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

Technically perfected turbulator system enables flue gases to swirl and better efficiency of the boiler. The feeding mechanism allows good cleaning of the pipe register. With the help of the active combustion control equipped with the Lambda probe we provide products with many advantages: Simple and clear control, The lowest fireplace load, Longer service life of the boiler, Module control allows longer combustion phase, The best efficiency with the lowest emission values, Emitted flue gases are harmless to the environment, Constant control of the combustion process, Continuous fan control, Optional programmed ignition. The control allows simple control of the boiler. Fuel ignition can also be activated via your cell phone. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of 0.40. Characteristics Unit TR 15 TR 20 TR 25 TR 30 TR 35 Nominal heat value kw 15 20 25 30 35 Lowest boiler power kw 8 15 15 15 20 efficiency at nominal power % 90,01-91 90,01-92 90,01-92 90,501-92 90,01-92 Combustion efficiency % 93,1-95,5 93,1-95,5 93,1-95,5 93,1-95,5 93,1-95,5 Container volume l 150 150 150 150 150 Loading door width and height mm 430 x 400 430 x 400 430 x 400 430 x 400 430 x 400 water quantity l 183 193 193 193 183 Chimney connection mm 160 160 160 160 160 Permissible operating pressure bar 3 3 3 3 3 Required chimney draft Pa 13 13 13 13 13 Max. flow temperature C 95 95 95 95 95 weight kg 735 735 735 735 760 Recommended accumulator size l 1800 1800 1800 2000 2000 height mm 1500 1500 1500 1500 1500 width mm 695 695 695 695 695 depth mm 1320 1320 1320 1320 1320 Height of the chimney connection mm 1221 1221 1221 1221 1221 Delivery tube R 5/4 5/4 5/4 5/4 5/4 Return tube R 5/4 5/4 5/4 5/4 5/4 Supply discharge fitting R 3/4 3/4 3/4 3/4 3/4 Thermal protection device fitting R 3/4 3/4 3/4 3/4 3/4 Electrical connection 230 V +10/-15 %/50 Hz 160 W for operation; 400 W for ignition WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 3

FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER LT Due to their wood gas combustion technology, Stadler LT firewood hot water central heating boilers enable energy saving heating. s are constructed for burning all types of wood and reach efficiencies of over 90%. They are completely made in Slovenia, thus showing high level of expertise. Development of the product brought such improvement that our company was granted with the national patent by the Slovenian Intellectual Property Office. These hot water boilers are constructed for for burning of 56 cm, or 33 cm long firewood. You should load the boiler with firewood as close together as possible, thus reaching uniform fuel structure and stable combustion conditions. Single load should be enough for several hours of operation. Fireplace volume equals to 130 dm3 and can be loaded with approx. 35 kg of firewood. The container should be loaded with firewood to its top limit, while taking care not to load the firewood too close to each other as this could cause jamming. Modern control enables you to burn different types of wood and to reach ideal combustion conditions with flue gases which are harmless to the natural balance. These boilers are equipped with modern fireplaces with hot combustion chambers made of temperature resistant ceramics. The hot combustion chamber allows swirling combustion of wood gases resulting in the combustion of all combustible substances in flue gases. Temperatures in the combustion chamber can reach over 1000 C, thus creating perfect combustion conditions. s can be installed into systems equipped with hot water reservoirs and room temperature control. The control regulates circulating pumps and motor driven three-way Characteristics Nominal heat value Unit kw LT 20 15-20 LT 30 25-30 valves, thus achieving balanced consumption of the reservoir's temperature layered water and longer heating time. Lowest boiler power kw 7 15 efficiency at nominal power % 90,1-91 90,3-91,2 Combustion efficiency % 92,1-93,1 93,3-94,5 Firewood container volume l 130 130 Loading door width and height mm 400 x 400 400 x 400 water quantity l 117 110 Permissible operating pressure bar 3,0 3,0 Max. flow temperature C 95 95 Upper chimney connection mm 160 160 Required chimney draft Pa 15 20 weight kg 480 520 Recommended hot water reservoir size l 1250 1500 height mm 1350 1350 width mm 660 660 depth mm 1280 1280 Height of the chimney connection mm 1400 1400 Delivery tube " 5/4 5/4 Return tube " 5/4 5/4 Water supply fitting " 1/2 1/2 Thermal protection device valve fitting " 1/2 1/2 Electrical connection 230 V +10/-15%/50Hz 160 W for operation; 400 W for ignition Our boiler is in compliance with all currently valid provisions on safety and construction design (e.g. DIN 4751 B1.1, DIN 4702, EN 303-5). It is tested for pressure and water tightness and factory equipped with a thermal protection device, thus enabling the installation in closed heating systems. Permissible operating pressure of the boiler equals to 3 bars. All integral parts are made of tested materials of suitable quality and thickness. s are also equipped with the CE 0036 marking. Flue gas sensor 4 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

Construction of the boiler is patent protected, as its development included several innovations which significantly contributed to the improvement of the combustion processes. Our family of products equipped with the Lambda probe is one of the best in EU. CONTROL The combustion process is regulated with a modern control via temperature probes. All data is promptly checked by the central control microprocessor which also performs corrective measures for the improvement of the combustion process. Control regulates the continuous control of the fan and the primary and secondary combustion air supply motor flap. The extremely efficient control also regulates the external heating system structures and allows control of operation via your cell phone. If the boiler is loaded with firewood, you can also start it with your cell phone. This novelty is appropriate especially when you are away from home longer than expected, or simply to make your home warm and comfortable at the time of your arrival. Technically perfected turbulator system enables flue gases to swirl and better efficiency of the boiler. The feeding mechanism enables good cleaning of the pipe register. Activation of the boiler is simple. This button activates the boiler. These, in buttons allow you to access individual menus and to fine-tune the operation of the boiler according to customer's demands. The combustion of firewood can be programmed via the ignition electrode. Preparation of firewood for the programmed ignition is simple and does not include special procedures. The control allows you to regulate your boiler via your cell phone and to ignite the fuel simply by calling the boiler control. The combustion chamber made of high-temperature resistant concrete ensures perfect combustion of wood gases. The reliable and robust fan equipped motor is continuously controlled and helps the fine-tuned control of the combustion process. Motor is protected with sheet metal cover which prevents all kinds of damage. The wiring of the boiler is made of temperature resistant cables and very clear. Power connection of the boiler can simply be performed at the terminal assembly on the external side of the boiler. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of 0.40. The measurement certificate classifies the boiler on the list of subsidized boilers. WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 5

FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER GT STADLER GT boilers belong to a new generation of firewood hot water heating boilers. With their wood gasification technology they enable modern and energy saving heating. They are constructed to burn all types of firewood of up to 54 cm or 33cm in length. Their combustion efficiency reaches over 90%. themselfs are designed and produced in Slovenia. By naming the product range STADLER we wished to show that the production is still active and adapts to new combustion conditions and techniques. In comparison with our boilers marked TR and LT, these boilers come with a simpler control. Nevertheless, they provide stable combustion processes enabled by the inovative construction. These boilers achieve excellent combustion parameters which are characteristic for wood gasification boilers. Quality production, controlled combustion process and high efficiency of these boilers beat the competition of the lower priced boilers by far. By using different types of wood, it is possible to achieve good combustion conditions in the boiler. Firewood burns in the lower part, whilst the supplied primary air leads the flame and wood gases downwards into the combustion chamber. When flue gases come through the burner nozzle, they are blown with controlled supply of secondary air. Flue gases mixed with the flame and fresh air swirl in the combustion chamber, and in touch with the red-hot fireproof clay, burn with extreme temperatures. The control regulates the combustion process via the temperature sensor in the chimney and sensors installed in the boiler and the accumulator. It also regulates the continuous control of the fan and the primary and secondary combustion air supply motor flap. Controlled supply of the combustion air enables low values of emmissions in flue gases which are significantly lower than the law regulated ones. s are equipped with an insulated hot combustion chamber made of fireproof clay which quickly reaches high temperatures and enables good combustion of wood gases. The efficiency boilers reache over 90% which points out the top-class echievement for boilers with lower level control without the Lambda probe. The hot combustion chamber enables the boiler to reach the optimal combustion Characteristics Unit GT 20 GT 30 process in only minutes. These boilers can be installed into systems equipped with hot water accumulators. We recommend the use of the heating system control because this is the only way to preserve different water layers in the hot water accumulator. Our boilers are in compliance with all currently valid provisions on safety and construction design (e.g. DIN 4751 B1.1, DIN 4702, etc.). They are tested for pressure and water tightness, factory equipped with a thermal protection device and can be installed in closed heating systems. The permissible operating pressure of boilers equals to 3 bars. We recommend the use of firewood with humidity of 25% which is achieved by drying it outdoors for 2 years. You should load the boiler with firewood as close together as possible, thus reaching uniform fuel structure and stable combustion conditions. Single load should be enough for several hours of operation. The volume of the fireplace is 105 dm3 and can be loaded with approx. 30 kg of firewood. You should load the container with firewood to the top of the doors, while taking care not to load them too close to each other as this could cause jamming. Nominal heat value kw 20 30 Lowest boiler power kw 10 15 efficiency at nominal power % 91 91 Combustion efficiency % 93 93 Container volume l 105 105 Loading door width and height mm 400 x 350 400 x 350 water quantity mm 117 110 Chimney connection diameter mm 160 160 Permissible operating pressure bar 3 3 Required chimney draft Pa 13 13 Max. flow temperature C 95 95 weight kg 498 513 Recommended accumulator size l 1250 1250 height mm 1350 1350 width mm 660 660 depth mm 1190 1190 Depth of the loading area mm 555 555 Height of the chimney connection mm 865 865 Delivery tube R" 5/4 5/4 Return tube R" 5/4 5/4 Supply discharge fitting R" 1/2 1/2 Thermal protection device fitting R" 3/4 3/4 Thermal protection device fitting 6 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

WOOD PELLET HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER PELET STAR Stadler PELET STAR hot water central heating boilers belong to a new generation of wood pellet boilers. They were designed by our company in cooperation with the Swedish company Ariterm. The BeQuem burner enabled the development of a completely automatic wood pellet boiler which guarantees reliable and safe operation with minimum cleaning and maintenance interventions. s are produced with the modern sheet metal treatment technique. Construction concepts provided the boiler with a touch of modern design, while respecting the ergonomic demands for the operation of the boiler. Construction of the boiler is produced in accordance with regulations DIN 4751 B1.1, DIN 4702, EN 303-5. s are equipped with the CE 0036 marking and can also be installed in smaller rooms to provide comfortable and energy saving heating. The side of the boiler is equipped with the weekly wood pellet silo, whilst the large ash chamber allows longer intervals between cleaning. Construction of boilers allows easy access to all internal surfaces and hence easier cleaning and maintenance. We recommend you to install your central heating system with a hot water accumulator which allows optimum boiler operation with low energy consumption (low-energy constructions and transition periods). In case of bigger consumption, the hot water accumulator amortizes the current lower burner operation capacity. Special construction of the BeQuem wood pellet burner allows reliable operation and high level of safety. Wood pellet feeding is arranged with a double stoker system where the lower stoker feeds wood pellets into the lower part of the combustion chamber. With such wood pellet feeding the ash is pushed further and the combustion chamber automatically cleaned. Such feeding technique makes the burner appropriate even with wood pellets of weaker quality which can now often be found on the market. Fire safety is ensured with temperature sensors and the cell block. Ignition and control of the flame are controlled with a special sensor. Characteristics Unit PELET STAR Nominal heat value kw 20 40 Lowest boiler power kw 5 20 efficiency at nominal power % 90,1-91 90,3-91 Combustion efficiency % 91,9-92,4 90,9-91,3 Wood pellet container volume l 250 250 Cleaning door width and height mm 330 x 250 330 x 250 water quantity l 126 140 Permissible operating pressure bar 3,0 3 Max. flow temperature C 95 95 Upper chimney connection mm 130 130 Required chimney draft Pa 15 15 weight kg 280 290 Recommended hot water reservoir size l 750 1000 height mm 1430 1430 Width of the boiler including the wood pellet container mm 1020 1020 Depth of the boiler with the burner and the fan mm 1350 1350 Height of the chimney connection mm 1330 1330 Delivery tube 1 1 Return tube 1 1 Supply fitting 1/2 1/2 Electrical connection 230 V+10/-15 %/50Hz 80 W for operation; 200 W for ignition 1 2 3 4 5 6 7 8 9 10 Combustion chamber made of high resistant alloy guarantees good combustion of wood pellets. Wood pellets are transported into the combustion chamber from below. Newly arrived pellets push the ash from the chamber, thus making cleaning of the chamber's burner unnecessary in the period of one heating season. Burner cleaning is simple. Unscrew it and simply remove from the boiler. LEGEND 1. Cell block 2. Transverse stoker 3. Fuel supply 4. Ignition electrode 5. Primary air pipe 6. Ignition pipe 7. Transport mechanism 8. Fan 9. Feeding stoker 10. Combustion chamber with wood pellets WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 7

WOOD PELLET HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER C 28 With the help of new innovative technologies wood pellet heating boilers enable comfortable, energy saving, and environment friendly heating. Firewood heating boilers represented the basis for the construction of wood pellet heating boilers. These boilers were constructed in cooperation with the HDG company and conform to the strictest regulations prescribed for such products. This claim is confirmed with the TÜV certificate. The boiler was reconstructed to burn wood pellets and now, in compliance with the prescribed flue gas emissions, enables combustion of wood pellets with efficiency of over 90%. s are equipped with an additional function which gives them advantage over other similar products. In case you run out of wood pellets or electric power, boilers also allow to burn firewood. Reorganization of the boiler to burn firewood is simple. Simply cover the opening of the burner and connect the draft control. The Swedish made burner allows integration with solid fuel boilers so that they serve as heat exchangers. Except for the environment friendly flue gases the burner operates in similar way as the oil burner. Ignition, operation and deactivation are automatic. Wood pellet feeding is performed with an extremely energy saving stoker which takes the pellets from the silo and feeds them into the burner. The burner can easily be set via the display. Combustion is regulated via the control installed on the burner. Burner operates in two levels in accordance with energy requirements. ADVANTAGES OF WOOD PELLET BURNING DEVICES construction is adapted to burn wood pellets, Enabled firewood burning, Completely automatic operation, Combustion with optimal efficiency, Good control enables energy saving operation, is made of 8 mm sheet metal, Efficiency of over 90%, No problems related to fuel preparation, Wood pellet supply similar to fuel oil supply, Care for the environment. Characteristics Unit C 28 PELET PX 22 GP 20 Nominal heat value kw 25 Lowest boiler power kw 10 efficiency at nominal power % 90,12 water quantity l 70 Chimney connection mm 130 Permissible operating pressure bar 3 Required draft Pa 13 Max. flow temperature C 95 weight kg 370 Recommended accumulator size l 1000 height mm 1070 width mm 797 Width of the boiler including the burner mm 1090 depth mm 660 Height of the chimney connection mm 780 Delivery tube 1 Return tube 1 Supply discharge fitting 1/2 Thermal protection device fittings 1/2 Electric connection 230 V/50 Hz 8 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

WOOD PELLET HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER EKO PELET Stadler EKO PELET hot water central heating boilers were designed with combination of firewood boilers and Swedish made burners. In this way boilers with the BeQuem wood pellet burners became automated units for heating of living quarters. Unlike the use of fossil fuels, the use of local energy resources, such as wood pellets, is harmless to the environment and decreases heating costs. These wood pellet boilers are equipped with a control which allows completely automated operation of the boiler without constant regulation. They regulate the supply of pellets from the container and the combustion process. s are also equipped with a pellet ignition device and flame control. The burner activates automatically as soon as the sensor in the boiler detects fall of water temperature bellow the preset value, and deactivates as soon as this temperature is reached. The volume of the factory offered wood pellet container equals to 0.6 m3 which is enough for approx. 10 days of operation. Alternatively you can order a larger container with volume of 0,93 m3. Our company also offers elements for the construction of even larger wood pellet containers which can be assembled in your boiler room or the room next to it. These boilers can easily be rearranged into firewood heating boilers by unscrewing the flange screws, removing the burner and turning it into the position which does not interfere with the operation of the boiler. Then, you have to install the cover over the burner on the external side of the boiler. Fix the cover firmly and prevent the flue gases from escaping. Cleaning of the boiler is also very simple. Open the lower door and remove the ash collected in the drawer. From time to time it is also necessary to check if the combustion chamber is clean. In case you notice any slag residue, remove it adequately. We do not recommend you to disassemble the burner during cleaning, however if this is necessary please call our authorised repair service centre. After each rearrangement of the boiler for burning firewood, clean the fireplace of the boiler and the space under the grate. The construction of the burner is equipped with a display showing mode of operation and temperature. Under the display, there are some arrow keys which enable you to scroll along the simple menu. With the use of these keys you can set the operation of the burner or simply control its operation. Calculation of the required boiler power m 2 cm 0,30 Apartment x Living quarters x Heat loss size height coefficient Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of 0.40. In case of simpler heating systems we recommend you to install a special pump. This special pump with a three-way valve ensures that the boiler first reaches the temperature of 60 C and then only emits the excess energy into the system. During the cool down phase, the pump and the three-way valve ensure that the water temperature in the boiler does not fall below 55 C, thus preventing the formation of condensate. If the system includes a hot water accumulator, the three-way mixing valve allows the accumulator to be filled. With the use of the water accumulator, better operation can be achieved, especially during transition periods when temperatures are not too low. model Wood pellet boiler capacity kw Firewood boiler capacity kw / 860 = Required boiler power Electric connection 240 V 50 Hz Power consumption 240 V 50 Hz Efficiency EKO PELET 20 10-20 30 450 W 60 W 91,5 % EKO PELET 40 25-40 40 600 W 90 W 90,7 % WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 9

WOOD PELLET AND FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER EKO PELET Kompakt EKO pelet Kompakt wood pellet hot water heating boilers are equipped with wood pellet containers located above the boiler where the domestic water heater is generally installed. These boilers are appropriate for installation in smaller spaces where there is desire for comfortable and energy saving heating. s are produced left or right oriented. They can easily be rearranged into firewood heating boilers by unscrewing the flange screws connecting the burner and the boiler, removing the burner and turning it into the position which does not interfere with the operation of the boiler and its safe loading. Then, you have to install the cover over the burner on the external side of the boiler. Fix the cover firmly and prevent the flue gases from escaping. Fasten the line of the draft regulator to the primary air flap of the lower door. Remove the safety barrier and the rectifier from the boiler. After you finish the above procedure, the boiler is rearranged to use firewood. CHARACTERISTICS OF FIREWOOD BOILERS: Stadler EKO hot water central heating boilers are constructed to burn 33 cm long firewood (logs are to be loaded transversely) and 56 cm long firewood (logs are to be loaded longitudinally to the boiler). They are intended for operation in the 90/70 C mode. The new way of flue gas conduction improves combustion processes during the burning of firewood. Loading doors enable loading of large logs. Constructions of boilers are produced in accordance with regulations DIN 4751 B1.1, DIN 4702 and EN 303-5. s are also equipped with the CE 0036 marking. Chimney must be constructed in accordance with solid fuel boiler chimney manufacturer's tables and must ensure drafts as described in the table of the brochure related to individual boiler models. s are equipped with large fireplaces, therefore we recommend you to burn your wood pellets or firewood in a downwards direction, thus prolonging the combustion time of a single load. During the burning phase, the draft regulator must constantly be set above 70 C, thus preventing overcooling of the return water and formation of condensate in the fireplace. We also recommend the installation of one of the insufficient water return prevention systems. Easy access to all internal surfaces enables easy cleaning and maintenance. Burner position during firewood burning. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of 0.40. model Eko Pelet Kompakt Firewood power kw Wood pellet capacity kw Delivery tube R Pellet silo for Kompakt l Self-standing pellet silo for Eko Pelet l water quantity l Weight EKO s kg L B H-Eko Kompakt DIMENSIONS (mm) Hs-Eko Pelet D F G d 20 20-25 10 20 5/4 300 600 126 280 655 640 1735 1170 930 540 550 160 40 35-40 25-40 5/4 330 900 164 360 855 640 1735 1170 920 540 550 130 10 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

HOT WATER CENTRAL HEATING ACCUMULATORS MODEL: AT Hot water accumulators represent intermediate central heating elements and are used in modern heating systems. They are used for accumulation of the excess thermal energy produced by the boiler and for evenly regulated supply of energy to different consumers. Hot water accumulators are indispensable in systems with installed firewood, wood pellet, or wood chip heating boilers. Firewood heating boilers do not allow the complete control of power without significant interruption of the combustion process. Firewood combustion cycle brings excess thermal energy which consumers cannot use at that moment therefore it is conducted to the hot water accumulator. After the fuel has burnt and the heating elements cooled down, the automatic control takes care for transfer of hot water from the accumulator to heating elements. Our production programme includes hot water accumulators of various sizes: 500, 750, 1000, 1250, 1500, 1800, 2000, and 3000l. Accumulators are equipped with fittings for connection of heating circles, sensors and thermometers. The number of used fittings depends on the complexity of the planned heating system prescribed by the manufacturer at the time of sale of the product or by other professional subjects. Model / values Unit AT 500 AT 750 AT 1000 AT 1250 AT 1500 AT 1800 AT 2000 AT 3000 Volume l 520 780 1080 1300 1570 1830 2090 3050 D-diameter mm 900 950 995 1150 1200 1300 1300 1500 D1+diameter including insulation mm 700 750 795 950 990 1090 1090 1290 H - height mm 1665 1867 2168 2023 2225 2230 2380 2610 H angled height mm 1700 1910 2210 2070 2300 2290 2460 2690 Total weight kg 112 144 176 190 211 242 258 330 Permissible operating pressure bar 3 3 3 3 3 3 3 3 Max. operating temperature C 95 95 95 95 95 95 95 95 Take care that the angled height is not greater than the room height, as this would prevent the installation of the accumulator. D1 Our production programme includes several standard volume hot water accumulator types: AT AT B AT BI AT B2I AT B3I AT I AT 2I AT 3I AT 3I PB WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 11

FIREWOOD HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER EKO in EKOs Stadler EKO heating boilers are constructed in accordance with new findings concerning wood combustion processes. Fireplaces are adapted for standard firewood lengths (33cm and 50cm). Construction of the fireplace also allows loading of somewhat longer logs. Permissible cutting length equals to +6cm. The above stated means, that it is possible to load the boiler with firewood of up to 40 cm and 56 cm in length. s EKO 12-25 are to be loaded with 33 cm long firewood, whilst boilers EKO 30-100 are to be loaded with 50 cm long firewood. s are designed for operation in the 90/70 C mode, whilst their return water preheating system improves the thermal load of the boiler. The new way of flue gas conduction improves combustion processes during firewood burning. Large loading doors allow easy loading of firewood into the fireplace which can be loaded with large quantities of firewood, therefore we recommend you to burn your firewood in a downwards direction, thus prolonging the combustion time of a single load. The heater temperature control is performed by setting the desired temperature on the control cabinet which represents an integral part of the boiler equipment. Equipment of EKO boilers also includes quality enamelled domestic water heaters. They are equipped with an Mg-anode which serves for enamel protection. s with EKOs marking (s - solo) are not equipped with hot water heaters, but can be additionally bought and installed. Construction of boilers is made with 3D-designing in accordance with all regulations related to boiler construction like DIN 4751 B1.1; DIN 4702, EN 303-5. s are equipped with the CE 0036 marking. and heater are tested for pressure and water tightness. The permissible operating pressure of the boiler equals to 3 bars. For the purpose of achieving high product quality, all integral parts of the boiler are made of quality materials. s are also factory equipped with thermal protection devices. Chimney must be constructed in accordance with solid fuel boiler chimney manufacturer's tables and must enable drafts as described in the table of the brochure related to individual boiler models. s are equipped with large fireplaces, therefore we recommend you to burn your fuel in a downwards direction. During the burning phase, the draft regulator must constantly be set above 70 C, thus preventing overcooling of the return water and formation of condensate in the fireplace. We also recommend the installation of one of the insufficient water return prevention systems. Easy access to all internal surfaces allows easy cleaning and maintenance. SCOPE OF DELIVERY: with insulation, Thermal protection device, Domestic water heater for EKO boilers, Thermometer, Cleaning kit. Models EKOs 12 and 14 are not delivered with the domestic water heater Firewood Fireplace Delivery Heater Required Weight Weight model power size tube water water draft EKO s EKO DIMENSIONS (mm) EKO quantity quantity EKO-s kw dm 3 R l l Pa kg kg L B Eko s Eko D F G d 12 8-12 52 5/4 84 18 230 620 470 1150 980 550 525 130 14 12-15 52 5/4 97 18 240 620 470 1150 980 550 525 130 25 20-25 80 5/4 115 115 20 260 320 655 640 1170 1830 930 540 550 160 30 25-30 97 5/4 115 126 21 270 330 755 640 1170 1830 920 540 550 180 35 30-35 100 5/4 115 120 21 285 340 755 640 1170 1830 920 540 550 180 40 35-40 114 5/4 140 144 24 310 380 855 640 1170 1830 920 540 550 180 50 40-50 165 6/4 140 160 25 350 420 855 740 1380 1930 1100 685 450 200 65 50-65 167 6/4 170 195 27 450 535 1020 820 1380 1930 1100 765 520 220 80 65-80 167 6/4 170 185 27 470 555 1020 820 1380 1930 1100 765 520 220 100 80-100 180 2 170 210 30 560 645 1120 880 1480 2030 1200 765 620 220 12 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

WOOD-FUELED HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER HS HS boilers were developed on the basis of long years of experience in the field of development and production of heating equipment. s are intended for burning all types of wood. They are distinguished by long inclined loading doors and a large combustion chamber which allow simple use and loading of the boiler with large quantities of fuel. Chimney connection is located at the back side of the boiler. s are equipped with a combustion chamber and a pipe register with turbulators for better heat exchange. Chimney must be constructed in accordance with the SCHIEDEL table for solid fuel boilers. Draft must comply with the values stated in the table for the selected model of the boiler. Construction of the fireplace and the perfect insulation guarantee maximum fuel efficiency. s are to be loaded transversally with firewood of up to 36 cm in length. Fuel burns in the lower side part of the boiler. Installation of the grate in the fireplace and installation of the flap on the secondary air door significantly improve the combustion process. The installed return water preheater and the water-cooled grate prevent the low-temperature corrosion. Easy access to all internal surfaces allows easy cleaning and maintenance. By purchasing additional burner control and special burner doors, your boiler can be rearranged to burn fuel oil. For domestic water heating you must connect the boiler with a self-standing water heater, because the construction of the boiler does not enable you upgrade boiler with a heater. s are distinguished by quality production as they are made with laser cutting of metal sheet and robot welding. s are also factory equipped with a thermal protection device. SCOPE OF DELIVERY with lining and insulation Thermometer Cleaning kit LEGEND 1. Fireplace loaded with firewood 2. Flue pipes 3. Exhaust of flue gases with a flap 4. Water-cooled grate 5. Ash space, drawer 6. Pipe register cleaning opening 7. Return water preheating 8. Return tube 9. Delivery tube 10. Panelling with insulation 11. Loading doors 12. Doors for cleaning and relighting the fire 13. Primary air flap 14. Safety tube 15. safety flow, supply, discharge 16. draft control fitting R ¾ 17. connection thermometer sensor R ½ 18. Protection door vertical grate 19. Fireproof clay 20. Mixing channel 21. Secondary air rotating flap 22. Thermal protection device Model HS Loading Firewood door power dimensions kw Fireplace size dm 3 Chimney connection Ø water quantity l Required draft Pa Weight kg Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of 0.40. Delivery Heater and return coonnection tube R R DIMENSIONS (mm) L B H L1 H1 A D 26 260x400 20-25 52 160 55 20 280 5/4 1 720 560 975 840 150 900 785 32 260x400 25-32 74 180 85 23 330 5/4 1 820 650 1035 940 150 950 830 44 260x400 35-43 88 200 100 25 410 5/4 1 875 650 1135 1000 150 1070 930 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 13

WOOD-FUELED HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER CENTRAL 28 Stadler Central series boilers are constructed fur burning firewood. Combustion in the lower side part and the vertical 4-draft conduction of flue gases enable good transmission of flue gas heat to the heated water. Combustion in the lower side part classifies the boiler in the series of slow-burning boilers which means that the loading interval is longer than with other types of boilers. Fireplaces are adapted to standard firewood lengths. Fireplace of the Central 28 boiler is adapted to be loaded with 33 cm long firewood. Special channel for the conduction of combustion air to individual combustion zones enables good combustion of fuel. The Central 28 boiler is equipped with a special fireproof clay combustion chamber where the previously not combusted flue gases in the fireplace are burnt. s also come equipped with a combustion grate made of grey cast iron which can be moved, thus enabling you to remove the ashes from the grate during the operation of the boiler. Additionally, the boilers are equipped with a thermal protection device and draft control. Vertically installed cleaning openings enable easy access to internal vertical channels. Construction of boilers respected all regulations related to boiler construction like DIN 4751 B1.1; DIN 4702, EN 303-5. s are equipped with the CE 0036 marking. s are also factory equipped with a thermal protection device. ESSENTIAL ADVANTAGES OF THE STOREY HEATING BOILER: Good efficiency and minimum environmental nuisance, Automated draft control enables slow-burning, Moving grate enables cleaning during operation, Single load is sufficient for several hours of burning, The boiler is adapted to burn firewood and certified for German market. The use of certified materials provides long service life of the boiler. L SCOPE OF DELIVERY with lining Thermometer Draft control Cleaning kit C28 B1 128 B1 128 128 C 24 C 28C 24 C 28 H3 H3 H3 H2 H1 H1 H2 H H1 B1 B B L1B1 L1 B L1 B1 model CENTRAL Heat power kw Fireplace size dm 3 water quantity l Chimney Chimney Connection Ø Ø mm mm Required draft Pa Outflow inflow R Weight kg DIMENSIONS (mm) L L 1 B B 1 H H 1 H 2 H 3 28 15-19 55 55 160 130 20 1 250 660 180 797 70 1070 788 885 125 14 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

WOOD-FUELED HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER CENTRAL 17 IN 23 Storey boilers are intended for installation and use in non-basement residential houses and residential apartment blocks with no central heating and no chance of classic boiler room installation. Combustion in the lower side part classifies these boilers in the series of slow-burning boilers which means that the loading interval is longer than with other types of boilers. s are extremely energy saving, thus making the fuel consumption of a single heating season very low. Dimensions and visual appearance are adapted for installation in fitted kitchens. The central heating installation should be executed in a way that enables horizontal connection to the heating system (at the side of the boiler). Such installation enables the boiler to be levelled with the edge of the kitchen working counter. Pipes routed vertically behind the boiler will cause the boiler to be unaligned with the fitted kitchen. s are equipped with a three-way chimney connection and vertical chimney connection with a cover. They are appropriate for burning of dry firewood of up to 25 cm in length. s should be connected to an Ø 118 mm diameter chimney (23 kw boilers to Ø 128 mm). Chimney draft should equal to 20 Pa. We recommend you to measure the chimney prior to the installation of the boiler. In case of low quality chimneys, such chimneys should be arranged to enable optimal operation of the boiler. All boilers are equipped with a thermal protection device, whilst new models come with a flexible loading cover enabling easier fuel loading. ESSENTIAL ADVANTAGES OF THE STOREY HEATING BOILER: Installed cooking plate allows reheating of your dishes, Room with the installed boiler does not require additional radiators, Good efficiency and minimal environmental nuisance, Automated draft control enables slow-burning, Moving grate enables grate cleaning during operation of the boiler, Single load is sufficient for several hours of burning, Use of certified materials provides long service life of the boiler. SCOPE OF DELIVERY C17 C23 with lining Thermometer Draft control Cleaning kit Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of 0.40. 600 161 300 134 200 1" 1 2" 3 4" 35 3 4" 70 1" 1 2" 850 23 17 23 17 H 785 130 1" 40 3 4" 556 610 3 4" 1" 70 260 1 2" 660 600 400 model CENTRAL Heat power kw Power (water) kw Power (environment) kw Container dm 3 Burner water quantity l Chimney Connection Ø mm Required draft Pa Outflow inflow R Weight cca 17 7-10 14 3 35 35 118 10-15 1 132 740 23 10-14 19 4 46 40 128 15-20 1 198 718 kg H mm WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 15

DUAL FIREPLACE FIREWOOD AND FUEL OIL CENTRAL HEATING BOILERS MODEL: STADLER TOBI Stadler TOBI central heating boilers are constructed as extremely energy saving boilers due to the installation of fuel oil and firewood boilers in a single construction. Both boilers use a single water reservoir, but completely separated fireplaces. Such design enables automatic rearrangement from burning of one type of fuel to another which cannot be achieved with combined boilers. s are basically intended for burning firewood in the 90/70 C operating mode. The fuel oil part of the boiler activates automatically after all of the fuel from the firewood fireplace has been used and the temperature dropped under the preset value. The fuel oil part of the boiler does not activate if the firewood fireplace is full and the preset temperature is reached. In case you deactivate the automatic system, these boilers only operate by burning firewood. A more modern construction concept classifies these boilers among the new generation of eco-friendly products as they operate in a similar way as hybrid cars. The firewood fireplace is equipped with modern burning in the lower side part of the boiler which enables controlled long burning process lasting even over 3 ½ h. The fireplace allows you to burn 33 cm long firewood. s are equipped with a return water preheating system and a cast iron grate which improves firewood combustion processes. Loading doors allow loading of large pieces of firewood. The special fireplace constructed for burning fuel oil is equipped with a hot combustion chamber and a turbulator in the third draft. Its design enables top-class efficiency of over 93%. Combusted flue gas emissions reach even more favourable parameters than required by law. The fuel oil part of the boiler is equipped with the SELTRON control. These boilers cannot be upgrades with domestic water heaters. Domestic water heaters can be installed as separated units which are then connected to the boiler. Ba purchasing the domestic water heater additionally, it is possible to control the temperature in the domestic water heater with the help of a pump. panelling is enamelled in the RAL 3000 or RAL 2004 colour combination. Our boilers are in compliance with all regulations regarding safety at work. Construction of the boiler is produced in accordance with regulations DIN 4751 B1.1, DIN 4702, EN 303-5, and is equipped with the CE 0036 marking. s are also equipped with a thermal protection device. The central heating system must compulsory include one of the system for lifting the return water as this is the only way to use the boiler with lower powers. If the boiler is not connected with the system for lifting return water the boiler condensates and causes poor combustion. This special pump with a three-way valve ensures that the boiler first reaches the temperature of 60 C, and emits only the excess energy into the system. At the same time it prevents the return water with temperatures lower than 55 C to enter the boiler, thus preventing the condensation. If the system includes a hot water accumulator, the three-way mixing valve enables the accumulator to be filled. With the use of the hot water accumulator, better operation of the burning device can be achieved, especially during the transition periods when temperatures are not too low, but still demand heating. model TOBI Power (fuel oil) kw Power (wood) kw Fireplace size dm 3 water quantity l Required draft Pa Weight kg Chimney Connection (fuel oil) Ø Chimney Connection (wood) Ø width mm height mm Required door width to enter the boiler with panelling into the room Required door width to enter the boiler without panelling into the room Efficiency (fuel oil) 20 15-20 20 86 105 15 230 130 160 990 1200 850 770 93,2 81,2 25 20-25 25 86 100 20 240 130 160 990 1200 850 770 93,4 81,5 % Efficiency (wood) % 16 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

FIREWOOD AND FUEL OIL HOT WATER CENTRAL HEATING BOILERS MODELS: STADLER EKOs and RLs These devices include two separate boilers. The basic boiler is the firewood boiler onto which the fuel oil boiler or gas oiler is installed. The firewood boiler is reinforced with two holders which enable safe installation of the fuel oil or gas boiler. Each boiler represents the best solution for itself as it is in compliance with all ecology standards. The boiler can additionally be upgraded with a separate domestic water heater, whilst the heating control takes place via the external control. Stadler EKOs heating boilers are constructed in accordance with new findings concerning wood combustion processes. Fireplaces are adapted for standard firewood lengths (33cm and 50cm). The construction of the fireplace also allows loading of somewhat longer logs. Permissible cutting length equals to +6 cm, thus enabling you to load the boiler with firewood of up to 40 or 56 cm in length. s EKOs 25 are to be loaded with 33cm long firewood, whilst boilers EKOs 30-40 are to be loaded with 50cm long firewood. s are designed for operation in the 90/70 C mode, whilst their return water preheating system improves the thermal load of the boiler. The new way of conduction of flue gases improves the combustion processes during firewood burning. Large loading doors enable easy loading of firewood into the fireplace. s can be loaded with large quantities of firewood, therefore we recommend you to burn your fuel in a downwards direction, thus prolonging the combustion time of a single load. L1 B1 H1 d G1 D1 50 H L B d F1 G F D Special Stadler RLs fuel oil and gas boilers are produced with welded frameworks made of larger dimensioned materials. fireplaces are equipped with a hot reversible chamber and turbulators within the pipes which allow combustion with efficiency of over 93%. Flue gas exhaust emissions are lower than required by law, especially NOx, CO, whilst the flue gas temperatures in the chimney do not reach 180 C. s are in compliance with all currently valid provisions on safety and construction design (DIN 4751 BI.1, DIN 4702, and EN 303-5). The basic equipment includes also the control cabinet for the regulation of the burner operation. Power Fireplace Required Weight Delivery L B H D F G d model les size water draft EKOs tube quantity EKOs kw dm 3 mm mm mm mm mm mm mm l Pa kg R 25 20-25 80 115 20 260 675 640 1170 930 540 550 180 5/4 30 25-30 97 126 21 270 785 640 1170 910 540 550 180 5/4 35 30-35 100 120 21 285 785 640 1170 910 540 550 180 5/4 40 35-40 114 144 24 310 855 640 1240 910 540 550 180 5/4 Power Required Weight Delivery L 1 B 1 H 1 D 1 F 1 G 1 d model (fuel oil) water draft MVs tube quantity mm mm mm mm mm mm mm RLs kw l Pa kg R 25 15-30 105 15 155 665 645 720 475 230 400 130 5/4" 35 30-40 95 15 190 665 645 720 475 230 400 130 5/4" WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 17

FUEL OIL HOT WATER CENTRAL HEATING BOILERS MODELS: STADLER RL and RLs Special welded Stadler RL boilers are constructed for burning fuel oil or gas and are made of the thickest certified sheet metals. fireplaces are equipped with hot reversible chambers and turbulators within the pipes which allow top-class combustion efficiencies of over 93%. Combusted flue gas emissions reach even more favourable parameters than required by law. The boiler is in compliance with all currently valid provisions on safety and construction design (DIN 4751 BI.1, DIN 4702, and EN 303-5). RL marked boilers are equipped with vacuum enamelled heaters for preparation of domestic hot water. Domestic hot water temperature can be controlled with the help of the pump. RLs boilers are delivered without the heater for preparation of domestic hot water. These boilers are distinguished by good 50 mm thick insulation. The panelling of the boiler is protected with powder enamelling. The basic equipment also includes the control cabinet for the control of burner operation. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of 0.40. SCOPE OF DELIVERY RL RLs with lining and insulation control Water heater control If the delivery includes the base of the boiler it is necessary to consider its height of 270 mm. Hot combustion chamber and turbulators Cleaning brush L B As optional equipment you can install an electric heater (2 kw) for domestic water heating during the summer. We recommend you to purchase the additional heater at the time of your order, as the subsequent installation is more expensive and complex. Hs G F D H Power Water Flow Weight Weight Chimney model water heater return RL RLs DIMENSIONS (mm) RLs, RL kw quantity l l R kg kg Ø mm L B H Hs D F G 25 15-30 105 115 5/4 225 155 130 665 645 1270 720 475 230 400 35 30-40 95 115 5/4 260 190 130 665 645 1270 720 475 230 400 50 40-60 135 140 5/4 300 220 160 815 645 1270 720 475 230 400 80 60-90 225 170 6/4 395 315 180 955 790 1450 900 650 370 450 100 90-110 240 170 2 330 200 200 1060 790 1450 900 635 365 450 18 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

FIREWOOD HOT WATER HEATING BOILERS MODEL: HDG Euro HDG Euro boilers are distinguished by very long loading intervals and efficiency of over 90%. They are effective, energy saving and comfortable for the user. Flue gas emission values are lower than all of the prescribed values. Contraction and production of the boiler are in accordance with all safety regulations. These boilers were granted the German innovation award and are equipped with the TÜV quality marking. Large fuel loading space significantly increases fuel reloading intervals. Cleaning of the boiler is easy as its doors are positioned in a way which enables easy access. s are delivered with installed panelling and are connected immediately. Connection with the power supply is very simple, as boilers include already prepared wiring with plug equipped cables. Combustion takes place in the lower side part of the boiler on the grate which allows wide selection of fuels. Along with the special combustion chamber, the robust and innovatively constructed burner nozzle provides swirling mixing of flue gases which ensures optimal combustion. After the combustion has finished, the flaps shut down and the fan deactivates. This prevents the boiler from cooling, whilst the next ignition is facilitated by the remaining charcoal. Grates are massive and equipped with a practical cleaning opening. The loading shaft is made of 10 mm thick quality steel sheet. Pneumatic cylinders facilitate opening of shaft doors. The system bolt of the loading shaft cover enables safe loading. The spacious conical loading shaft can be filled with firewood or bulk material. If you select the right size of the device, you will be able to get the necessary heating energy with only one loading of the boiler daily. Planning of the central heating system must include a hot water accumulator as such reservoir combined with the boiler control guarantees environment friendly combustion. The hot water accumulator significantly increases comfort of burning as it takes over the excess energy and transfers it back if necessary. The correct selection of the hot water accumulator enables very long loading intervals. During the summer, burning of a single load can be sufficient for several days of domestic water use. Volume of the accumulator depends on customer s demands regarding comfort, boiler power, volume of the loading shaft and the consumption of hot water for room heating. Combination of the firewood boiler equipped with the hot water accumulator and the solar energy device meets the demands of the modern heating system. Lambda control enables very low emission values, high efficiency and low fuel consumption. The adjustable primary and secundary air motors provide accurate amounts of combustion air to specific combustion areas. Primary air takes care for uniform combustion power, whilst the secundary air takes care for the lowest emission values and high efficiency throughout the combustion process. Predtok 1 1/4 792 1606 Lambda Control constantly measures and displays the following parameters: Quantity of the remaining oxygen in flue gases, Temperature of flue gases for uniform efficiency, Temperature of the heating boiler and water reservoir, Lifting of the temeperature of the return water. Calculation of the required boiler power m 2 cm 0,30 x x / 860 = Required Apartment Living quarters Heat loss size height coefficient boiler power Poorly insulated buildings, shady and high altitude positions require the use of a heat loss coefficient of 0.40. Model Heat power 1184 1106 220 110 0180 110 Povratni tok 11/4 88 88 objemka za praznjenje/ polnjenje 1/2 783 Vnosna mera 813 599 1920 1990 1 150 104 5 Območje odpiranja 510 1255 For more information, please contact the manufacturer, local salesman or the assembler and ask for a detailed brochure Lowest Loading Loading space Chimney Operating Required Max. flow boiler space width and water connection pressure draft weight temperature power volume depth quantity Ø C kw kw l mm l mm Bar Pa kg HDG Euro 30 30 29 220 560 x 407 162 180 3 13 95 940 2000 HDG Euro 40 40 29 220 560 x 407 162 180 3 13 95 953 2500 HDG Euro 50 50 29 220 560 x 407 162 180 3 13 95 979 3000 1514 1374 Recommended accumulator size l WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 19

FIREWOOD HOT WATER HEATING BOILERS MODEL: HDG Turbotec 2 4 3 1 5 6 LEGEND 1. Loading space (340 l), 2. Cleaning opening, 3. Lambda probe and the flue gas sensor, 4. Fan, 5. Loading from above optional and with additional payment, 6. HDG lambda control, 7. Loading doors - front, 8. Primary and secondary air control, 9. Cleaning opening. 7 9 8 Thermal protection device sensor 1 / 2 VL 1 1 / 4 varnostni toplotni izmenjevalec 1 / 2 RL 1 1 / 4 Praznjenje 1 / 2 820 576 743 HDG Turbotec boilers are firewood heating boilers with large loading space of up to 340 l. they are intended tu burn firewood with lengths of up to 1 m, thus prolonging the interval between loadings. In case you have fine fuel at your disposal, you can also additionally order the upper boiler loading doors. Turbotec boilers are distinguished by very long loading intervals and efficiency of over 90%. They are effective, energy saving and comfortable for the user. Flue gas emission values are lower than all prescribed values. Construction and production of the boiler are in accordance with all safety regulations. They are ideal for use in the craft industry, agriculture and forestry, and are equipped with the TÜV quality label granted by a German institution. Cleaning of the boiler is easy as its doors are positioned in a way which enables easy access. s are delivered with installed panelling and are connected immediately. Connection to the power supply is very simple, as boilers include already prepared wiring with plug equipped cables. The robust and innovative constructed nozzle provides good combustion. The interior of the combustion chamber is shielded with fireproof concrete. Swirling of flue gases in the combustion chamber provides optimal combustion. After the combustion has finished, the flaps shut down and the fan deactivates. This prevents the boiler from cooling, whilst the next ignition is facilitated by the remaining charcoal. s are made of quality steel sheet. Primary and secondary air servomotors deliver the necessary air directly in the combustion zone. Primary air takes care for constant performance of the boiler, whilst the secondary air takes care for the lowest flue gas emission values. If you select the right size of the device, you will be able to obtain the necessary heating energy with only one loading of the boiler daily. Planning of the central heating system must include the hot water accumulator as such accumulators combined with the boiler control guarantee environment friendly combustion. Installation of the hot water accumulator significantly increases comfort of burning as it takes over the excess energy and transfers it back if necessary. The correct selection of the hot water accumulator enables very long loading intervals. During the summer, burning of a single load can be sufficient for several days of domestic water use. Volume of accumulators depends on customer's demands regarding comfort, boiler power, volume of the loading shaft and the consumption of hot water for room heating. HDG Turbotec boilers are equipped with HDG lambda control 1 which ensures very low emission values, high efficiency and low fuel consumption. Adjustable primary and secondary air motors deliver accurate amounts of combustion air to specific combustion areas. Primary air takes care for uniform combustion power, whilst the secundary air takes care for the lowest emission values and high efficiency throughout the combustion process. 1394 1218 540 280 180 270 576 1939 1785 1606 60 Power Loading Loading Loading Chimney Required Operating Max. flow Model space volume space depth space width water quantity connection Ø draft pressure temperature weight kw l mm mm l mm Pa Bar C kg HDG Turbotec 50 L 50 340 1100 540 370 180 15 3 95 940 HDG Turbotec 60 L 60 340 1100 540 370 180 15 3 95 940 20 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

HDG WOOD CHIP AND WOOD PELLET HEATING SYSTEMS MODEL: HDG Compact These boilers are appropriate for burning wood pellets and wood chips with humidity of up to 45%. s can also burn Class 6 and 7 fuels. The compact and favourable priced versions are appropriate for use in households, agriculture, craft industry and public institutions, basically everywhere where a reliable and economic operation is required. Constant power is provided by the automatic technology of angled or movable grates. s are equipped with automatic ignition via the hot air fan. Two large external ash collectors make operation and maintenance easy. s are distinguished by low emission values and optimum efficiency of over 90%. The reliable fuel loading technology and the fire extinguishing device provide absolutely safe operation. Cell block is especially accurately manufactured and takes care for proper loading. Vertical surfaces of the heat exchanger provide better heat transfer. In emergency situations boilers can also burn firewood. HDG Compact electronic control device of the boiler takes care for good combustion technology and is a product of our development programme. It can also be upgraded for control of different heating systems. All actual conditions of the operating device are shown on the display. Fuel loading takes place directly on combustion grates. Fuel supply and primary and secondary air can be adjusted independently. Even in case of bigger shares of non-combustible materials, the power stays constant due to the technology of angled grates. After reaching a certain loading level, the fuel ignites with the help of hot air. Automatic ignition increases the device control comfort. Device operates with optimum emission values. You should prevent long lasting smouldering during the time of ember preservation, thus preventing the contamination of heat exchanger and chimney surfaces. In combination with the fire extinguishing equipment, loading of the boiler via the patented cell block and feeding stoker guarantees perfectly safe operation. With the help of the cell block, the combustion chamber is completely separated from the silo and the transport unit and represents patented protection from the return fire. The next advantage lies in cutting of large firewood by the cell block into smaller pieces, thus creating ideal combustion conditions. The circular skimming device for takeover of wood mass from the silo is appropriate for simple, unproblematic takeover of wood chips, wood pellets, wood shavings, sawdust and wood briquettes from the silo. Maximum stoker length is 6 m (max. weight of fuel = 250 kg/m3). The takeover device can be installed also in larger containers, provided that they do not require complete emptying. Two pretightened joint levers are equipped with rotating spring feathers which rotate and skim the wood mass onto the stoker. Material takeover takes place along the transverse and open transport stoker. In case of square and round containers (6 m diameter) emptying takes place with the transverse stoker. The loading system can be installed in different positions in 180 radius according to the option of the silo connection. These systems are described in details in technical brochures. Our experts will make a special offer with technical solutions which meet the customer's demands for each individual device. For more information, please contact the manufacturer, local salesman or the assembler and ask for a detailed brochure. Power Power Combustion Combusted air water Operating Required Flow Model area gas temperature flow quantity quantity pressure draft temperature weight kw kw C g/s l Bar Pa C kg HDG Compact 25 26 7,7 26 140-180 19,0 110 3 7 95 650 HDG Compact 35 35 8 35 140-180 26,8 110 3 7 95 650 HDG Compact 50 50 12 50 100-240 32,6 167 3 13 95 980 HDG Compact 65 65 12 65 100-240 45,1 167 3 13 95 980 HDG Compact 80 80 23 80 100-240 52,0 221 3 16 95 1200 HDG Compact 100 100 30 100 100-240 74,6 210 3 20 95 1540 HDG Compact 150 150 45 150 100-240 111,9 450 3 20 95 2140 HDG Compact 200 190 57 190 100-240 147,6 450 3 20 95 2220 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 21

FUEL OIL HOT WATER CENTRAL HEATING BOILERS MODEL: STADLER Z doors open in the left and right direction, thus allowing easy access to flue pipes. Access to the flame pipe is enabled after removing the burner. s are equipped with the basic control and safety equipment. For higher levels of modern heating systems regulation, control equipment of the most renowned foreign manufacturers is used. Stadler Z heating boilers are Slovenian products with a high level of installed technology. Their new construction is a result of Slovenian knowledge, long years of experience and continuous development and improvement. They are planned with a 3D construction technology which provides precise design of each part of the boiler. The modern construction design is based on the triple draft principle. Flue pipes are not equipped with turbulators. s are constructed in accordance with high environmental standards and are produced in standard versions for operation with 4 bars of overpressure. For higher pressures (>10 bar), modified construction is used. You can choose between 90/70 C and 110/90 C operating modes. The ideal construction and the flame pipe type of flue gas conduction provide optimum combustion with efficiency of over 95%. Such efficiency means almost perfect combustion with minimum flue gas emissions which is, at this time of environmental awareness, more and more important. Products are equipped with the CE 0036 marking. s are intended for burning liquid or gas fuels. Advantageous boiler dimensions allow installation in small areas. Operation of our boilers is good even in case of saccadic and oscillating loads. Operation resistance is minimal, whilst the operation is very quiet. s are well insulated and installed on a stable support frame. On the top, boilers are equipped with walkable covering made of ribbed sheet metal which facilitates the installation and later maintenance operations. Larger boilers are equipped with railings intended for cleaning and supply and with the entrance and exit ladder. B SCOPE OF DELIVERY with left or right opening doors fixation panel Electric switch cabinet Lacquered pannelings with insulation Z Flue Model Heat Flue Safety Supply power water pipe return tubes discharge weight B D E F H H quantity 1 I K L L 1 L 2 Ø cca Z kw l mm DN DN R kg 130 80-130 170 810 585 635 900 1060 1190 790 200 1035 1400 220 200 80 40 2 405 180 130-180 235 860 595 660 955 1120 1360 850 250 1165 1550 240 230 100 50 2 555 230 180-230 280 860 595 660 955 1120 1360 900 250 1365 1750 240 230 100 50 2 660 290 230-290 330 895 595 685 955 1170 1360 1055 250 1465 1850 240 230 100 50 2 750 350 290-350 340 895 595 685 955 1170 1360 1055 250 1565 1950 240 230 100 50 2 820 450 350-460 805 1145 630 830 1200 1440 1640 1500 250 1800 2170 230 280 100 50 2 1180 580 460-580 815 1145 630 830 1200 1440 1640 1500 250 1900 2270 230 280 100 50 2 1335 700 580-690 930 1215 695 870 1245 1505 1795 1755 300 2145 2560 280 280 150 65 2 1665 850 690-850 885 1215 695 870 1245 1505 1795 1755 300 2285 2710 280 280 150 65 2 1880 1050 850-1050 1350 1320 700 920 1285 1605 1835 1845 300 2460 2860 255 330 150 65 2 2240 1250 1050-1250 1360 1320 700 920 1285 1605 1835 1845 300 2660 3060 255 330 150 65 2 2625 1600 1250-1600 1520 1370 670 950 1335 1660 1970 2195 350 3025 3470 270 370 200 100 2 2905 2300 1800-2300 2800 1565 880 1150 1660 1985 2345 2750 350 3640 4130 310 470 200 100 2 4790 2900 2400-2900 3250 1690 950 1220 1775 2150 2440 3570 350 4230 4730 325 470 200 100 2 6650 3500 3000-3500 3750 1905 1030 1300 1960 2256 2640 3580 350 4520 5110 420 470 200 100 2 8100 4500 4370-4700 4950 2400 2100 1500 3100 2700 3100 1560 2800 5020 5900 705 600 200 100 2 11500 5000 4800-5560 5600 2400 2100 1500 3100 2700 3100 1560 3500 5720 6600 755 600 200 100 2 12900 22 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

LOW PRESSURE STEAM BOILERS MODEL: STADLER ZP Stadler ZP low pressure steam boilers are used for production of steam with overpressure of 0.5 bars. They are Slovenian made with a high level of installed technology. Their new construction is a result of Slovenian knowledge, long years of experience and continuous development and improvement. They are planned with a 3D construction technology which provides precise design of each part of the boiler. The modern construction design is based on the triple draft principle. Flue pipes are not equipped with turbulators. s are constructed in accordance with high environmental standards. The ideal construction and the flame pipe type of flue gas conduction provide optimal combustion with efficiency of over 95%. Such efficiency means almost perfect combustion with minimum flue gas emissions which is, at this time of environmental awareness, more and more important. Products are equipped with the CE 0036 marking. s are intended for burning liquid or gas fuels. Advantageous boiler dimensions allow installation in small areas. Operation of our boilers is good even in case of saccadic and oscillating loads. Operation resistance is minimal, whilst the operation is very quiet. s are well insulated and installed on a stable support frame. On the top, boilers are equipped with walkable covering made of ribbed sheet metal which facilitates the installation and later maintenance operations. Larger boilers are equipped with a ladder and walkable platform with railings. doors open in left and right direction, thus allowing easy access to flue pipes. Access to the flame pipe is enabled after removing the burner. s are equipped with the basic control and safety equipment. For higher levels of modern heating system regulation, control equipment of the most renowned foreign manufacturers is used. SCOPE OF DELIVERY Low pressure steam boiler with left and right opening doors Two-colour lacquered panneling with insulation Base plate for the installation of the burner Operation and safety pressostats (3 pcs) Level switch Inspection glass (2 pcs) Pressure gauge Pressostat installation fitting ZP Model Power Steam Steam Safety Condense DN Flue quantity takeover tubes tubes pipe weight A B C D H H1 H2 H3 H4 L L1 Ø cca ZP kw kg/h DN1 DN2 DN3 R mm kg 130 80-130 180 80 50 40 2 1400 810 205 435 1445 900 635 1060 585 1035 220 200 450 180 130-180 250 80 50 40 2 1550 860 205 490 1495 955 660 1110 595 1165 240 230 600 230 180-230 320 80 50 40 2 1750 860 245 490 1495 955 660 1110 595 1365 240 230 700 290 230-290 400 80 50 40 2 1850 895 225 580 1545 955 685 1160 595 1465 240 230 820 350 290-350 520 100 65 40 2 1950 895 205 680 1545 955 685 1160 595 1565 240 230 870 450 350-460 640 100 65 40 2 2170 1145 250 700 1980 1200 830 1430 630 1800 230 280 1750 580 460-580 800 125 65 40 2 2270 1145 250 800 1980 1200 830 1430 630 1900 230 280 1840 700 580-690 960 125 65 40 2 2560 1215 455 865 1870 1245 870 1470 695 2145 280 280 2000 850 690-850 1170 150 80 40 2 2710 1215 455 1015 1870 1245 870 1470 695 2285 280 280 2140 1050 850-1050 1450 150 80 40 2 2860 1320 500 1100 2000 1285 920 1595 700 2460 255 330 2 650 1250 1050-1250 1920 200 100 40 2 3060 1320 500 1300 2000 1285 920 1595 700 2660 255 330 2940 1600 1250-1600 2200 200 100 40 2 3470 1370 615 1415 2120 1335 950 1650 670 3025 270 370 3450 2300 1800-2300 3200 250 125 40 2 4130 1565 850 1560 2440 1660 1150 1925 880 3640 310 470 5650 2900 2400-2900 4000 2x200 150 40 2 4730 1690 500+875 1585 2620 1775 1220 2070 950 4230 325 470 7500 3500 3000-3500 4800 2x200 150 40 2 5110 1905 500+930 1640 2800 1960 1300 2250 1030 4520 420 470 9320 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 23

GAS AND FUEL OIL HOT WATER BOILERS MODEL: STADLER ZV In these times, when the environmentally aware part of the world tries to lower the emissions of greenhouse gases into the environment, it is very important that the fossil fuels heating systems operate as efficiently as possible, with perfect combustion, and low fuel consumption. Our company already several years ago decided to actively contribute to the development of such heating devices with no impact to the environment. On the basis of 40 years of tradition in the field of boiler production and intensive investments into development, our company produced a new family of hot water boilers named STADLER ZV. These boilers are constructed on the triple draft principle with low Nox emissions. Due to the low load of the combustion chamber ( 1,2 MW/m3) and the conduction of flue gases through the pipe register, these boilers provide optimum combustion with top-class efficiency. s are made in accordance with Directive 97/23/CE PED and the Slovenian SIST EN12953 standard regarding gas or fuel oil burning. s are also equipped with a substantially dimensioned heat part. At the time of dimensioning of flame pipes, flue pipe packages and the water part, special attention was given to thermodynamic compliance and fast transfer of temperature to the water. s are also equipped with large volume water parts appropriate for optimum temperature control in different operating conditions. Inspection openings for entrance into the water part are easily accessible and allow easy access. s are well insulated and installed on a support frame. The operating overpressure is adapted to customer's demands. Our company produces boilers intended for pressures of 6-16 bars with the maximum operating mode of up to 160 C depending on the order or the investor's temperature mode. Minimum operating mode equals to 60 C. The external boiler fitting must provide protection of the hot water boiler against too low temperatures of the return tube. Equipment of the boiler can also include the system for protection against condensation. Good boiler insulation prevents heat loss into rooms and enables stable thermal operation. s are insulated with two layers of 60 mm thick Type ZV Heat power water quantity Transport weight Operating weight water side flue side Flue side volume width lengt height kw l 6 bar 16 bar 6 bar 16 bar mbar mbar m 3 B L H 800 800 1300 2250 2650 3550 3950 20 6,3 1,3 1350 2850 1650 1000 1.000 1800 2550 2950 4350 4750 55 6,7 1,6 1550 2900 1850 1500 1.500 3800 3500 4000 7300 7800 57 7,2 2,6 1750 3750 2000 2000 2.000 5000 5200 5800 10200 10800 52 8 3,2 1850 4150 2100 2500 2.500 6000 6500 7600 12500 13600 65 8,6 4,2 1950 4350 2200 3000 3.000 7200 6900 8200 14100 15400 84 9,8 5,1 2000 4600 2250 4000 4.000 8000 9100 10300 17100 18300 145 8,7 5,8 2100 5200 2350 5000 5.000 9500 10500 11800 20000 21300 120 11,5 6,3 2300 5500 2550 6000 6.000 11500 13600 16200 25100 27700 164 11,7 8,3 2550 5800 2800 7000 7.000 17500 19500 23000 37000 40500 170 12,5 8,8 2850 6775 3200 8000 8.000 19000 21500 25300 40500 44300 155 11,5 12,3 2900 7250 3250 9000 9.000 21000 24200 27600 45200 48600 167 13,2 14,7 3000 7600 3400 10000 10.000 22800 25100 28500 47900 51300 156 13,5 16,7 3100 7950 3500 12000 12.000 25500 27300 34500 52800 60000 172 12,5 19,4 3200 8150 3600 24 15000 15.000 28000 35000 43000 63000 71000 163 14 23,5 3400 8500 3800 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

LMF10 ALUR lamella insulation which makes total insulation 120 mm thick. Construction of the boiler enables to connect the burner to a special flange, which is to be installed on the neck of the combustion chamber. Combined with»low NOx«burners, our boilers achieve very low emission values (NOx < 100 mg/kwh). These boilers are equipped with double doors at the front side which open in the left and right direction, thus enabling easy access to pipe exchangers. Back side of boilers includes inspection opening of the combustion chamber, opening for the control of the flame and the flue cabinet. The flue cabinet is equipped with inspection covers and the pipe with a valve for condensate discharge. The flue cabinet can also be installed with a motorised flue flap for prevention of ingress of cool air into the boiler when it operates in idle mode. Above the flue cabinet, it is possible to install a heater for reduction of flue gas temperature which additionally increases the efficiency of the device and lowers the fuel costs. Such installation can lower the fuel consumption for up to 10%. The equipment of the heater can also include the system for protection against condensation. Lower fuel consumption enables additional decrease of CO2 emissions and lesser impact on the environment. Low resistance at flue gas and water sides, low radiation loss, and simple maintenance and cleaning represent additional advantages of these boilers. equipment includes safety equipment in accordance with SIST EN12953 standard, including the intermediate flange piece for installation of the safety and control equipment. The quality control of Weishaupt burners enables top-class control of the combustion process. Our company upgrades the Weishaupt control cabinets in such way, that they also allow the control of peripheral systems in the boiler room. Output signals of the boiler and control cabinet enable the regulation and control of the operation via the CNS. If the boiler room contains several boilers, they can be controlled via the cascade regulation with diagnostics of the device operation. s are equipped with the platform and a ladder. On the top, boilers are equipped with walkable covering made of ribbed sheet metal which facilitates the installation, operation control and maintenance operations. Our company manages all inquiries in a project way and adapts boilers to customer's demands. At the investor's demand, the company can take care for complete delivery of the equipment with all installations. In the name of the investor, our company can also elaborate all necessary documents for the preparation and execution of the project, and the technical acceptance. Modern 3D planned ZV boiler 's cross section shows the construction design which provides combustion with low flue gas emissions. Substantially dimensioned material cross sections do not burden the materials and prolong the service life. s are distinguished by the modern laser and CNC technology machining, whilst joint welding is performed with the help of powder welding processes. Welding is strictly controlled by the internal control and outside institutions. Type ZV Torch Burner Flue Flue Flow, Flow, Flow, Safety Safety Safety Water Bleeding diameter connection height connection connection height return PN 16 return PN 16 return PN 16 valve 6 bar PN 16 valve 8 bar PN 16 valve 16 bar PN 16 discharge Ø H1 Ø H2 20 C 30 C 40 C DN DN DN PN 40 PN 40 800 630 630 250 1260 100 80 80 40 32 32 40 40 1000 660 730 250 1510 100 80 80 40 32 32 40 40 1500 730 850 350 1610 125 100 100 50 40 40 40 40 2000 870 875 400 1660 150 125 100 65 50 50 40 40 2500 930 910 450 1710 150 125 125 65 50 50 40 40 3000 960 930 500 1760 200 150 125 80 65 65 40 40 4000 1060 950 550 1810 200 150 125 80 65 65 40 40 5000 1150 1025 600 1860 200 150 150 100 65 65 40 40 6000 1200 1100 650 1960 250 200 150 100 80 80 40 40 7000 1225 1200 700 2100 250 200 150 100 80 80 40 40 8000 1310 1225 750 2150 250 200 200 100 80 80 40 40 9000 1400 1280 800 2200 300 250 200 100 80 80 40 40 10000 1475 1320 900 2250 300 250 200 100 80 80 40 40 12000 1550 1400 900 2400 350 250 250 125 100 80 40 40 15000 1650 1500 1000 2550 350 300 250 125 100 80 40 40 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 25

WOOD RESIDUE, WOOD CHIP AND WOOD PELLET HEATING SYSTEMS BIOFLAMM Biomass is becoming more and more important economic factor as it enables energy independence and discontinuation of fossil fuel use which represent excessive impact on the environment. Due to the increasing prices of fossil fuels and financial country incentives for biomass equipment, investment into this equipment become very profitable in short-term. Our company has been producing boilers and biomass equipment for almost 30 years and has developed and still develops a wide range of products. Equipment is technologically adapted so it can be installed practically in every room, even in smaller boiler rooms which were planned for fuel oil boilers. The company strives for improvement of products, especially regarding the combustion technique, with solutions for combustion of chemically compromised wood residues and with the use of wide range of granulation and moisture. s are adapted also for burning wood pellets, thus allowing the use of biomass boilers even in cities, industrial facilities and other settlements. BIOFLAMM HEATING SYSTEMS MODEL: VE/SREB s are produced with the installed reactor with the step grate. They are produced by welding certified quality boiler sheet metal in accordance with DIN 4702 and 4751. Contraction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. The production process is controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Products are equipped with the CE 0036 marking. In the first draft, boilers with integrated burner are shielded with fireproof clay A 40 or A 60, depending on the fuel the device is planned for. Construction of the boiler allows to burn wood residue with humidity of up to 45%. s are equipped with a large combustion chamber and well dimensioned first and second draft for deposition of large particles of floating ash. They are equipped with two horizontal drafts and three vertical drafts routed through the pipe package. The inspection-cleaning doors are positioned on the side of the boiler (top, bottom) and on the back side, thus allowing easy access. All larger boilers are equipped with walkable platforms and railings, intended for cleaning and supply, and with entrance and exit ladders. They are also equipped with the automatic cleaning and ash removing system. The exterior of the boiler can be installed with automatic deashing which transfers the ash directly into the ash container. At the flue gas exhaust it is necessary to install a fan and a flue gas deduster, thus achieving dedusting of up to 80 mg/m3. Where the demands are very strict it is necessary to additionally install electric or fabric filters. Fabric filters enable cleaning of dust particles of up to 10 mg/m3. The entire device is controlled by the Lambdamatik micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. The standard scope of micro processing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is possible to supply customers with a control for remote regulation and inspection of the combustion process and for the control of peripheral units. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers or low pressure steam boilers with powers of up to 2 MW, temperatures 140 C and operating pressure 4.5 bars). model Power kw water quantity l height mm width mm lengt mm Safety flow Flow return Flue connection mm Weight kg V 3 116 570 1875 1138 1180 DN 50 DN 50 250 1500 V 4 174 980 1990 1310 1700 DN 50 DN 50 250 2100 V 5 291 1076 2003 1403 2040 DN 60 DN 80 300 2860 V 6 407 1985 2212 1538 2170 DN 65 DN 80 300 3715 V6 / 7 500 2300 2212 1538 2624 DN 65 DN 100 300 4150 V 7 600 2600 2214 1671 2624 DN 65 DN100 300 4570 V 8 750 2950 2442 2022 2785 DN 65 DN 100 400 6250 V 9 900 3580 2497 2052 3005 DN 65 DN 100 400 7770 V 10 1100 4210 2697 2102 3243 DN 80 DN 125 450 8900 V11 1250 4760 2833 2204 3570 DN 80 DN 150 500 10105 V12 1500 5230 2843 2360 3904 DN 80 DN 150 500 11623 V13 1750 6190 2839 2360 3945 DN 80 DN 150 500 12860 V14 2000 6560 2839 2360 4495 DN 100 DN 150 500 14500 V15 2200 7380 2839 2360 5045 DN 100 DN 150 500 16200 26 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

Model Heating power kw power kw Weight kg BIOFLAMM HEATING SYSTEMS MODEL: TRB/VA This heating device comprises the pre-fireplace reactor TRB and the VA boiler. The combination of these two components is used everywhere where the combustion conditions are difficult due to the higher humidity or due to the problematic fuel. Bioflamm multi draft VA boilers are used as heat exchangers and places for flue gas burn down. s are equipped with two horizontal drafts and three vertical drafts routed through the pipe packages. The inspection-cleaning doors are positioned on the side of the boiler (top, bottom) and on the back side, thus allowing easy access. In especially tough operating conditions boilers are shielded with quality fireproof clay in the first draft. Large dimensioned drafts and vertical pipe packages provide this heat exchanger with low temperature flue gases and enable high efficiency. All larger boilers are equipped with walkable platforms with railings intended for cleaning and supply and with entrance and exit ladder. They are produced by welding certified quality sheet metal in accordance with DIN 4702 and 4751. The construction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. The production process is controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Products are equipped with the CE 0036 marking. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers or low pressure steam boilers with powers of up to 6 MW, temperatures 140 C and operating pressure 4.5 bars). The automatic Bioflamm TRB pre-fireplaces with movable grates and automatic deashing enable the combustion of very problematic fuels. Reactors are constructed as a water-cooled pipe cage construction. The frame of the burner is shielded with quality fireproof clay A 40 or A 60, depending on the fuel the device is planned for. The quality movable transverse grates made of 24% chromed alloy ensure long service life and quality combustion on grates. Grates are installed next to each other, are simple, can be individually replaced, and form several movable grate layers. In case of extra humid, ash rich, or slag forming fuels, the Bioflamm degassing reactors with special air injection systems improve the combustion with their controlled combustion air fans. The primary air fan regulates the degassing process on the grate, whilst the secondary air fan enables combustion during the degassing of the formed flue gases. Separation from the fireplace and the boiler enables fast control in accordance with DIN 4751 Part 2. Reactors are produced in two construction versions; TRB N for humid fuels and TRB T for dry fuels. They are also equipped with the automatic cleaning and ash removing system. The exterior of the boiler can be installed with automatic deashing which transfers the ash into the ash container. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers with powers of up to 6 MW, temperatures 140 C and operating pressure 4.5 bars). In the past years, the company also developed an extra version of reactors marked TRB LK for connection of grain dryers or dryers of the sawdust accumulated during wood pellet production. Reactors are made of double-walled steel sheet frame where the air is directed into individual combustion zones. On the internal side, reactors are shielded with fireproof clay, whilst their external side is substantially insulated to prevent heat radiation into the environment. Grate movements and combustion air injection are similar to those of the basic version. The entire TRB/VA device is controlled by the Optimatika+ micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. The standard scope of micro processing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is possible to supply customers with a control for remote regulation and inspection of the combustion process and for the control of peripheral units. At the flue gas exhaust of the boiler it is necessary to install a flue gas deduster. Where the demands are very strict it is necessary to additionally install electric or fabric filters. Fabric filters enable cleaning of dust particles of up to 10 mg/m3. Water quantity l Flow return DN Lengt mm Width mm Height mm Center of the flame pipe mm Diameter of the flame pipe mm Height to the stoker mm TR-B 5N 343 291 4600 235 50 2776 1036 1721 964 580 989 TR-B 6N 479 407 5000 295 50 2786 1113 1741 999 640 1029 TR-B 7N 706 600 5230 307 50 2796 1190 1791 1034 710 1029 TR-B 8N 883 750 5500 318 65 2801 1421 1841 1044 784 1029 TR-B 9N 980 830 5700 350 65 2816 1498 1861 1079 800 1029 TR-B 10N 1295 1100 6000 381 65 3303 1421 1880 1109 860 1054 TR-B 11N 1470 1250 6400 412 65 3313 1575 1899 1139 880 1054 TR-B 12N 1765 1500 7900 432 65 3810 1498 1964 1149 900 1079 TR-B 13N 2059 1750 8100 475 80 3820 1575 2034 1199 1000 1079 TR-B 14N 2353 2000 8600 540 80 3830 1804 2109 1224 1050 1079 TR-B 15N 2588 2200 9250 625 80 3910 1960 2184 1249 1100 1079 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 27

BIOFLAMM HEATING SYSTEMS MODEL: TREB These heating devices were developed with the integration of transverse TRB reactors and VE boilers. This version is very good in coping with problems of combustion of all types of problematic fuels and allows installation in smaller boiler rooms. s allow the combustion of wood mass with humidity of up to 50% and wood mass with chemical substances which accumulate in the wood industry and could previously not be used as fuel due to the excessive emissions of harmful substances in flue gases. s are also appropriate for burning wood pellets and are equipped with a large combustion chamber and well dimensioned first and second draft for deposition of large particles of floating ash. They are equipped with two horizontal drafts and three vertical drafts routed through the pipe package. The external side of the boiler is equipped with a special system of channels for the supply of primary air under the grates. This feature improves the formation of wood gas as well as the combustion process. The inspection-cleaning doors are positioned on the side of the boiler (top, bottom) and on the back side, thus allowing easy access. All larger boilers are equipped with walkable platforms with railings intended for cleaning and supply, and with entrance and exit ladder. They are produced by welding certified quality sheet metal in accordance with DIN 4702 and 4751. The construction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. Production process is controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Products are equipped with the CE 0036 marking. The entire device is controlled by the Optimatika+ micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. The standard scope of micro processing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is possible to supply customers with a control for remote regulation and inspection of the combustion process and for the control of peripheral units. At the flue gas exhaust of the boiler it is necessary to install a flue gas deduster. Where the demands are very strict it is necessary to additionally install electric or fabric filters. Fabric filters enable cleaning of dust particles of up to 10 mg/m 3. s are factory shielded with fireproof clay A 60, which is resistant to high temperatures released during combustion. They are also equipped with a special system for the supply of primary and secondary air. The secondary air is conducted along special channels located in the body of the fireplace and directed with nozzles through the fireproof clay panelling into both drafts. Supply of the primary and secondary air is controlled via the continuously controlled fans. The entire device is controlled by the micro processing control via information received from the Lambda probe and temperature sensors. Model Heat power kw water quantity l height mm width mm lengt mm Safety flow Flow Flue connection mm TREB 5 291 1076 2403 1403 2040 DN 40 DN 80 300 3280 TREB 6 407 1985 2612 1538 2170 DN 50 DN 80 300 4110 TREB 7 600 2600 2612 1671 2624 DN 50 DN100 300 4970 TREB 8 750 2950 2614 2022 2785 DN 50 DN 100 400 6840 TREB 9 900 3580 2942 2052 3005 DN 50 DN 100 400 8410 TREB 10 1100 4210 2997 2102 3243 DN 65 DN 125 450 9530 TREB 11 1250 4760 3097 2204 3570 DN 65 DN 150 500 13080 TREB 12 1500 5230 3233 2360 3904 DN 65 DN 150 500 14020 TREB 13 1750 6190 3343 2360 3945 DN 65 DN 150 500 14810 TREB 14 2000 656 0 3339 2360 4495 DN 65 DN 150 500 16550 TREB 15 2200 7380 3339 2360 5045 DN 80 DN 150 500 18230 Weight kg 28 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

BIOFLAMM HEATING SYSTEMS MODEL: SRF-RK These boilers are appropriate for burning relatively dry wood chips with humidity of up to W 45, and wood pellets. They include a fireplace and a heat exchanger. Fireplaces with the movable step grate represent the basic part of these boilers. Fireplaces are shielded with quality fireproof clay. Construction of the boiler enables burning relatively clean wood residue and wood pellets. s are equipped with a large combustion chamber which enables good combustion. The front side of the fireplace is equipped with primary and secondary air fans. The air is conducted into the combustion process along a special system of channels and air injection nozzles, thus achieving swirling of flue gases and further increasing the combustion. fireplaces are equipped with horizontal heat exchangers. Three draft heat exchangers are equipped with channels for first inversion of hot flue gases, whilst the other two inversions take place through pipe packages. Large dimensioned drafts horizontal pipe packages provide the boiler with low temperature flue gases and enable high efficiency. They are produced by welding certified quality boiler sheet metal in accordance with DIN 4702 and 4751. Contraction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. The production process is controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Additional quality control is provided by the company TÜV Sava Ljubljana and other institutions taking care for product quality control. s are equipped with thermal protection devices for protection against overheating. The horizontal heat exchanger pipes are cleaned pneumatically or in accordance with the special programme. The inspection-cleaning doors are positioned on the front of the boiler (top, bottom), thus allowing easy access for cleaning of horizontal drafts. They are also equipped with the automatic cleaning and ash removing system. The exterior of the boiler can be installed with automatic deashing which transfers the ash directly into the ash container. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers or steam boilers with powers of up to 10 MW, temperatures 160 C and operating pressure 10 bars). s are shielded with fireproof clay A 40 or A 60, depending on the used fuel and operating conditions. In case the boilers burn dry fuel or wood pellets, they are factory shielded with fireproof clay A 60, which is resistant to high temperatures. They are also equipped with a special system for the supply of primary and secondary air. The secondary air is conducted along special channels located in the body of the fireplace and directed with nozzles through the fireproof clay panelling into both drafts. Supply of the primary and secondary air is controlled via the continuously controlled fans. The entire device is controlled by the micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. The standard scope of micro processing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is possible to supply customers with a control for remote regulation and inspection of the combustion process and for the control of peripheral units. At the flue gas exhaust of the boiler it is necessary to install a flue gas deduster. Where the demands are very strict it is necessary to additionaly install electric or fabric filters. Fabric filters enable cleaning of dust particles of up to 10 mg/m3. Smaller boilers are delivered welded as a whole, whilst, larger boilers come in two parts which are later assembled together in your boiler room. Assembly in the boiler room is especially welcome in case of low passages where the transport into the boiler room is less favourable. Type Bioflamm SRF-RK Power (flame) kw Useful boiler power kw Weight kg water quantity l Flow Return tok DN Lengt mm Width mm Height mm SRF-RK 300 343 300 4600 720 50 2776 1036 2820 SRF-RK 400 479 400 5000 1330 50 2786 1113 2820 SRF-RK 500 706 500 5230 1560 50 2796 1190 2890 SRF-RK 750 883 750 5500 1980 65 2801 1421 2940 SRF-RK 900 980 850 5700 2390 65 2816 1498 2960 SRF-RK 1000 1295 1100 6200 2820 65 3303 1421 3080 SRF-RK 1250 1470 1250 6400 3190 65 3313 1575 3190 SRF-RK 1500 1765 1500 7900 3510 65 3810 1498 3220 SRF-RK 1750 2059 1750 8300 4150 80 3820 1575 3430 SRF-RK 2000 2353 2000 8600 4380 80 3830 1804 3500 SRF-RK 2200 2588 2200 9250 4940 80 3910 1960 3880 WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 29

BIOFLAMM KURILNI SISTEMI MODEL: TRF-RK 30 These boilers are appropriate for use where the biomass humidity cannot be controlled or where the humidity cannot be dried out and therefore remains very high. In the first and second draft, boilers are shielded with quality fireproof clay. The quality movable transverse grates made of 24% chromed alloy ensure long service life and quality combustion on grates. Construction allows to burn inferior and problematic humid wood residues which could previously not be used as fuel due to the excessive emissions of harmful substances in flue gases. s are equipped with a large combustion chamber with the first inversion of hot flue gases over the fuel where the first phase of fuel drying begins. The large quantity of fireproof clay radiates the temperature on the fuel which moves along the grate, thus drying it additionally. The front side of the fireplace is equipped with primary and secondary air fans. The air is conducted into the combustion process along a special system of channels and air injection nozzles, thus achieving swirling of flue gases and further increasing the combustion. The well-dimensioned second draft serves also for deposition of large particles of floating ash. fireplaces are equipped with horizontal heat exchangers. Three draft heat exchangers are equipped with channels for first inversion of hot flue gases, whilst the other two inversions take place through pipe packages. Large dimensioned drafts horizontal pipe packages provide the boiler with low temperature flue gases and high efficiency. s are produced by welding certified quality boiler sheet metal in accordance with DIN 4702 and 4751. The construction is made in accordance with TRD and all regulations and norms of SIST, EN-DIN and VGB. The production process is constantly controlled by our experts as the company is certified in accordance with ISO 9001, module B and module D. Additional quality control is provided by the company TÜV Sava Ljubljana and other institutions taking care for product quality control. s are equipped with thermal protection devices for protection against overheating. The horizontal heat exchanger pipes are cleaned pneumatically or in accordance with the special programme. The inspection-cleaning doors are positioned on the front of the boiler (top, bottom), thus allowing easy access for cleaning of horizontal drafts. They are also equipped with the automatic cleaning and ash removing system. The exterior of the boiler can be installed with automatic deashing which transfers the ash directly into the ash container. The standard version of boilers operates with overpressure of 3 bars and the operating temperature of the flow of 120 C. On special demand, boilers can also be produced for operation in tougher conditions (hot water boilers or steam boilers with powers of up to 10 MW, temperatures 160 C and operating pressure 10 bars). s are factory shielded with fireproof clay A 60, which is resistant to high temperatures. They are also equipped with a special system for the supply of primary and secondary air. The secondary air is conducted along special channels located in the body of the fireplace and directed with nozzles through the fireproof clay panelling into both drafts. Supply of the primary and secondary air is controlled via the continuously controlled fans. The entire device is controlled by the micro processing control via information received from the Lambda probe and temperature sensors. This control regulates the combustion process as well as the peripheral units from the takeover of the wood mass from the silo all to the cleaning of flue gases. Standard scope of microprocessing control delivery includes the system for calling of 6 telephone numbers in case of standstill of any component of the device. With additional payment it is Type Power Useful Weight water Flow Lengt Width Height Bioflamm (flame) boiler power quantity Return possible to supply customers with a control for remote TRF-RK kw kw kg l tok DN mm mm mm regulation and inspection of the combustion system and TRF-RK 300 343 300 4100 720 50 2776 1036 2250 for the control of peripheral units. At the flue gas exhaust TRF-RK 400 479 400 4500 1330 50 2786 1113 2250 of the boiler it is necessary to install a flue gas deduster. TRF-RK 500 706 500 4730 1560 50 2796 1190 2390 Where the demands are very strict it is necessary TRF-RK 750 883 750 5220 1980 65 2801 1421 2440 to additionally install electric or fabric filters. Fabric TRF-RK 900 980 850 5530 2390 65 2816 1498 2500 filters enable cleaning of dust particles of up to TRF-RK 1000 1295 1100 5700 2820 65 3303 1421 2880 10 mg/m 3. Smaller boilers are delivered welded as a TRF-RK 1250 1470 1250 5900 3190 65 3313 1575 2899 whole, whilst larger boilers come in two parts which are TRF-RK 1500 1765 1500 7200 3510 65 3810 1498 2960 later assembled together in your boiler room. Assembly TRF-RK 1750 2059 1750 7600 4150 80 3820 1575 3030 in the boiler room is especially welcome in case of TRF-RK 2000 2353 2000 8150 4380 80 3830 1804 3080 low passages where the transport of the boiler is less TRF-RK 2200 2588 2200 8640 4940 80 3910 1960 3210 favourable. WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si

DEVICE CONTROL Controls with the Lambda probe Lambdamatika and Optimatika+ are installed in Rital cabinets which include all control elements for the entire system, continuous motor drives, protection of drive units, and the device for calling of 6 telephone numbers. On special order they can also be installed with modems for connection with the remote control. The cabinet is equipped with the main switch (depending on the supply power of electric motors) and the emergency switch. Doors of the cabinet are equipped with the microprocessor with a display and a keyboard for direct access into the combustion parameter setting program. Use of the program and the input of desired data is simple as the program allows scrolling with cursor keys and includes simple commands. The programme is made as a multi-level programme device operator level and repair or fine-tune expert level. VISUALIZATION The communication package for remote control of data and for the visualization of operation is used for control when the operator is out of the boiler room. The connection is established with the help of the modem and internet, or directly via the cable in case of small distances. In case of the cable connection, the visualization works trouble-free for 24 h, but demands an amplifier in case of distances greater than 200 m. Long-term connection via your telephone will cause disturbances during monitoring of current values due to the signal strength fluctuation. Significant data about device operation and reports of disturbances can be followed on the PC display. This way enables the operator-supervisor the access to all required data, which is why he can quickly react in cases of device malfunctioning. On the basis of these data, the supervisor makes corrective measures and adapts the operation to desired parameters. If the supervisor is unable to repair the malfunctioning he must immediately contact the manufacturer's service team which will take care for it with no major problems. With the permission of the investor, the manufacturer's service team can enter into the communication system. The visualization allows access to different levels of operation, depending on the data to be checked. All levels enable formation of excel charts and analyses of operation in individual time periods. Because this is a complex heating device, we recommend the operator to plan adequate maintenance interventions on the basis of number of hours of operation. COMPANY PRESENTATION OUR 150 YEARS Company WVterm from Maribor continues the TVT Boris Kidrič company's tradition in the field of boiler production. The beginning of industrial production reaches back in 1863 when the railway carriage and steam locomotive overhaul facilities were constructed. In 1970 the TVT Boris Kidrič, proizvodnja tirnih in cestnih vozil company signed a contract with the German STADLER company. Later, TVT became the biggest producer of boilers in the former Yugoslavia. Unfortunately, this big company could not avoid the crisis which appeared after the break-up of Yugoslavia. In 1995 an ownership transformation occurred and a new company WVterm was founded. During the past years, WVterm proved to be a vital export oriented company. The changed approach to work enabled better conditions in all fields of operation. The operation economics provides the company with a favourable business partner position. The company experienced rapid growth during the past years and today employs approx. 80 workers instead of the original 27. Due to the local conditions, export orientation was compulsory and today represents over 60% of all production. Our biggest partners come from the EU market. Besides the EU market the company is also present in the markets of the former Yugoslavia where the TAM STADLER trademark is still appreciated. Our perspective is built on experience upgraded with hard development work and with the aim to develop good products interesting for the market. With the internal and external potentials we significantly renewed and expanded our production programme. Efficiencies as well as low flue gas emissions and design of our products are now at the same level as the European competition. The conformity of products is guaranteed with the company s TÜV certificates which represent an integral part of documentation. One of the founding aims of the market appearance is to renew the old trademark that is to establish a positive contact with the market. We strive to restore the good name of the STADLER TVT trademark with hard work and quality production. Use of the trademark is protected both at home and abroad with number Z-9670961. Besides this trademark we are also present in the wood biomass market with Bioflamm and HDG Bavaria trademarks. The company provides HDG boilers in Slovenia and other countries of the former Yugoslavia. Company's production programme is very wide and with its Made in Slovenija products covers almost all areas of hot water boiler production. In the last years, the company increasingly invested in new technologies and has already caught up with technical development of its European competitors, thus keeping its competitiveness in the EU. During the last years, the welding technology was modernised with new pulse welding machines and robot welding of boilers and components. Preparation of boiler parts is based on top-class laser cutting of sheet metal and CNC technology for sheet metal and pipe forming. This technology helped us to achieve the production and productivity which is comparable with European competitors. WVterm d.o.o., Valvasorjeva 73, 2000 Maribor, Tel.: +386 2 429 28 10, Fax: +386 2 420 21 67, wvterm@wvterm.si 31