THE BIG FIVE NATURAL REFRIGERANTS IN DIFFERENT INDUSTRIAL APPLICATIONS. MAYEKAWA EUROPE S.A.,Leuvensesteenweg 605, 1930 Zaventem, Belgium

Similar documents
Global Solutions for Ammonia Industrial Refrigeration

Mayekawa Mfg. Co., Ltd. Kuniaki Kawamura

Our natural refrigerant technology and energy-efficiency solutions

ACTUAL ENERGY CONSERVATIONS BY USING NH3/CO2 REFRIGERATION SYSTEM

FIELD CASES WITH NATURAL REFRIGERANTS IN DEVELOPING COUNTRIES

Ammonia Refrigeration & Scenario in Industrial Refrigeration. By Ramesh Paranjpey ASHRAE Fellow Life member

TECHNOLOGY and MARKET TRENDS

Development of high temperature Heat Pumps using a low GWP refrigerant

Natural Refrigerant Market Trends

MAYEKAWA MFG. CO., LTD Botan Koto-ku, Tokyo , JAPAN TEL:(81) FAX:(81)

MAYEKAWA. kongres. 45th HVAC&R CONGRES AND EXHIBITION : IMPROVING ENERGY EFFICIENCY IN CLIMATE AND OZONE FRIENDLY LATEST REFRIGERATION TECHNOLOGIES

HFCs or the Old Refrigerants - what is the best Choice?

Mayekawa Mfg. Co., Ltd. Kuniaki Kawamura 1

Environmentally friendly refrigeration systems for industrial use

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Emerging Refrigeration Technologies

EN aquatech.piovan.com

Energy Efficiency Considerations in Refrigeration Systems

Use of transcritical CO 2 in industrial applications

Industrial Refrigeration System using NH3/CO2 Refrigerant NewTon - For Cold Storage in Japan and Others -

CO 2 Ice Bank Answer to the next requirements

Brazed Plate Heat Exchanger for CO Applications

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Chapter 1 Preface & General

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

: REFRIGERATION & AIR CONDITIONING COURSE CODE : 6023 COURSE CATEGORY : A PERIODS/ WEEK : 6 PERIODS/ SEMESTER : 90 CREDIT : 6 TIME SCHEDULE

Refrigerants & Cooling in renovation buildings

Campbell Soup Company Extends Use of CO2 Systems Into Their Operations

natural refrigerants - global trends & developments

R717 ROMANIAN REFRIGERATION SYSTEMS ANALYSIS Professor Gratiela-Maria TARLEA, Ph.D

COMPACT CO 2 /NH 3 REFRIGERATION UNIT FOR THE COLD STORAGE

System Design, Commissioning, Operation

Eco Compact Series GAS HEAT PUMP

FACT SHEET 9 Large Air-Conditioning (air-to-air)

WATE R -C OOLE D WATE R C H ILLE R S

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

R&D ON HEAT PUMPS WITH NATURAL WORKING FLUIDS IN JAPAN

world natural refrigerants trends market availability, technology trends & the impact of policy

Customers. The core of our innovation. Feeding&Conveying Drying Dosing Temperature Control Refrigeration. Granulation

Magnetic Refrigeration. Study Case

From the Field to the Supermarket

Ammonia. Background on ammonia as a refrigerant

Natural Refrigeration with Hydrocarbons Emerson s R290 Solutions

Trends and Perspectives in Supermarket Refrigeration

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS

Thermodynamics II Chapter 5 Refrigeration

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

Gas Heat Pump (GHP) Presented for Panasonic Heating & Cooling Systems by Lee Howes Consultant Sales Engineer

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

2. CURRICULUM. Sl. No.

FACT SHEET 9 Large Air-Conditioning (air-to-air)

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

The cold chain in the fishery sector. Refrigeration Technology Review

Rational Use of Energy

Exhibition Hall 1. Fachprogramm. Technical Programme

Environmentally friendly systems for convenience stores

Emerson R290 Solutions for Commercial Refrigeration Applications

Comparison Ammonia / Secondary Refrigerant System against Direct Evaporation of HCFCs /HFCs

Optimization of Cooling Systems

Air Conditioning and process cooling Energy Components at a Glance

Packaged Ammonia Chillers with Variable Frequency Drives powerpac

State of Art and Potential of the Gas Absorption Heat Pump Technology. Marco Guerra. Absorption Technology Expert

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

F-GAS DEMAND-BASED. Rack unit. TEKOPACK. Rack unit. TEKOPACKduo plus.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Commercial CO 2 Refrigeration Systems

TYPICAL INITIAL OUTPUT OF A CO 2 HEAT PUMP

Postprint.

Air to Water Heat Pump Utilising Natural Refrigerant C02

The lowest energy consumption when using R290 LBP fixed speed compressors in a plug in ice cream conservator

LG Electronics AE Company, Commercial Air Conditioning

PACKAGED REFRIGERATION EQUIPMENT

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

This presentation is posted for public use. ACEEE does not endorse any product or service.

Advantages of R290 (Propane) and other hydrocarbons

SUBCRITICAL & TRANSCRITICAL SYSTEMS

CASE STUDY AIR-CONDITIONERS

Why to decide on a Rotorcomp compact unit screw compressor

LG Electronics AE Company, Commercial Air Conditioning

Commercial CO2 Refrigeration Systems. Guide for Subcritical and Transcritical CO2 Applications

FACT SHEET 6 Transport Refrigeration

Midwest Industrial Initiative Webinar: Industrial Refrigeration

Natural Refrigerants.

Hydrocarbons as refrigerants

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

HYDROCARBONS, HEAT PUMP, HOME LAUNDRY DRYER: ENVIRONMENT FRIENDLY APPLIANCE

Green economy with natural refrigerants

Mitsubishi Electric Guide to Chiller Technologies. Information Guide 58

THE INSTITUTE OF REFRIGERATION

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Introduction of Panasonic CO2 refrigeration system. Panasonic Corporation Refrigeration and Air-Conditioning Devices Business Division

PHASE-IN of natural refrigerants. Prof. Dr. Armin Hafner NTNU Norway

Refrigeration and Air Conditioning

Transcription:

THE BIG FIVE NATURAL REFRIGERANTS IN DIFFERENT INDUSTRIAL APPLICATIONS Jan Boone MAYEKAWA EUROPE S.A.,Leuvensesteenweg 605, 1930 Zaventem, Belgium Tel. 32-2-757-9075, Fax. 32-2-757-9023, e-mail : jan.boone@mayekawa.eu NATURAL 5 LINE-UP. Mayekawa was founded in 1924 and is to-day one of the world s largest industrial refrigeration companies. It actively promotes the NATURAL 5 refrigerants, including ammonia, CO2, hydrocarbon gasses, air and water. Mayekawa is active in ammonia compressors for more than 85 years, for hydrocarbons and CO2 for more than 40 years. In the NATURAL 5 overview table the different solutions are summarized for each natural refrigerant from cryogenics, freezing, cooling, air conditioning up to heating. Kulak, Kortrijk, June.13th, 2012 DOC.2012-345 R0 Page 1

FIELD CASES NEWTON3000 (NH3 COMPRESSION REFRIGERATION + CO2 SECONDARY BRINE) Mycom developed the NEWTON3000, a semi-hermetic compressor for use in industrial refrigerated warehouses, based on 2-stage screw compressors and IPM drive motor. The design targets were : High efficiency Low charge (by use of direct expansion system and CO2 as secondary brine) Less leakage (by use of semi-hermetic motors) The photo illustrates the compact NEWTON3000 with semi-hermetic compressor-motor built on the NH3 condenser, oil separator, NH3/CO2 cascade evaporator/condenser, CO2 receiver, control panel etc. The benefits of the IPM motor are : 5 to 10% better in efficiency 40% smaller in size High rotation speed possible The field reference is a Food Distribution Center installed in Japan using NEWTON3000 modules producing -30 C CO2 by evaporating NH3 at -34 C. The case study shows that the power consumption and the CO2 emission were reduced with 30% for the NEWTON3000 compared to the conventional system. Kulak, Kortrijk, June.13th, 2012 DOC.2012-345 R0 Page 2

NH3 COMPRESSION REFRIGERATION An overview of most commonly used piston and screw compressors, by showing the theoretical gas displacement volumes, is given with range 15->1300 m3/hr for pistons and 200->15.600 m3/hr for screw compressors. Page 13 shows an 80.000m3 Food Store Plant in France using for the freezing part NH3/CO2 secondary brine equipment producing 1200kW CO2 at -30 C. The machines are operating approx. 30.000 hrs. Mycom compound screw compressors(4x) with individual NH3 circuit, each connected to their cascade NH3-evaporator/CO2-condenser(installed on top of the common CO2 receiver with liquid pumps) are equipped with variable speed control. Minimum NH3 charge is obtained by applying plate in shell type heat exchangers. Page 14 shows an Ice Cream Factory with big size Mycom compound compressor units(part of the plant) installed since 2003 producing 3450 kw at -42 C with NH3 compression, having approx.28.000 hrs of operation. NH3 HEAT PUMPS The NH3 heat pumps are executed with high pressure compressors to cover the higher output temperature requirements. The reciprocating compressor model N6HK is a 50 bar compressor, of which many compressors are operating in the field, covering a swept volume from 120 up to 200 m3/hr depending on the rotation speed controlled by means of a frequency convertor. New higher pressure reciprocating compressor models N4HS and N6HS are available very soon. For the 50 bar screw compressors, 3 models are available in the swept volume range of 400 to 3900 m3/hr depending on the rotation-speed with capacity range 190 kw up to nearly 10 mw depending on the required hot water outlet temperature. HP field reference 1 is an over-compression HEAT-PUMP to produce 60 C hot water for meat factory process. The plant scheme shows on the bottom side the refrigeration plant with heat produced at the condenser at condensing temperature of 40 C. The heat pump plant is shown on the top side : Kulak, Kortrijk, June.13th, 2012 DOC.2012-345 R0 Page 3

The heat pump compressor takes the gas from the high pressure side of the refrigeration plant at the refrigeration compressor outlet to the low pressure side of the heat pump compressor via a gas cooler and a suction gas liquid heat exchanger. The heat pump is compressing the ammonia gas from 40 C to 65 C and produces hot water of 60 C from the inlet water at 12 C by using the sensible heat exchanger and the suction gas/liquid heat exchanger. With this combination of heat exchangers it is possible to achieve a coefficient of heating performance from 6.0 up to 9.0 The unit layout shows the compressor-motor set with the oil separator, the sensible heat exchanger, condenser and high pressure liquid receiver. The photo s of the installation show the heat pump system installed at the machine room and the thermal stratification tank applied for the buffering of the hot water. The plant is operational since 2008 and operated approx. 4000 hrs with a hot water output of 400kW at 60 C. HP field reference 2 is an over-compression HEAT- PUMP to produce 77 C hot water for district heating. The plant scheme shows on the bottom side the refrigeration plant with heat produced at the condenser at condensing temperature of 30 to 40 C taken from the low stage heat recovery evaporator. The heat pump plant is shown on the top side : The heat pump compressor takes the gas from the high pressure side of the refrigeration plant at the heat recovery vessel at the low pressure side of the heat pump compressor. The heat pump is compressing the ammonia gas from 30/40 C to 80 C and produces hot water of 77 C from the inlet water at 60 C. With this system it is possible to achieve a coefficient of heating performance from 4.0 up to 5.2, with heating output capacity from 407kW to 1104kW depending on the intermediate ammonia temperature(30->40 C) and the system load (1800->3600rpm) per compressor. Two compressors are installed in this heat pump plant. The unit layout shows the compressor-motor set with the oil separator. The photo s of the installation show the heat pump system installed at the machine room with low stage compressors and heat exchangers. Kulak, Kortrijk, June.13th, 2012 DOC.2012-345 R0 Page 4

CO2 TRANCRITICAL HOT WATER HEAT PUMP Mycom developed the ECO-CUTE with a semi-hermetic 150 bar piston type compressor for production of hot water or hot air by using transcritical CO2 compression. The source can be water or air. On page 19 an Industrial Hot water Production Package is shown with air-source (alternative watersourced) The field reference is a 90 C hot water supply installation for a company complex in Japan. The ECO-CUTE produces the water (which is available at maximum 65 C) up to 90 C which is than buffered in the Hot Water Storage Tank. The hot water production capacity is approx.90kw per hour. From the hot water storage tank the water is used at controlled temperature for the different purposes in the building. The application targets for this hot water production unit are hospitals, hotels, welfare institutions, sport facilities, bathing facilities, facilities for boarding, food factories etc. The case study shows that the power consumption and the CO2 emission were reduced with 62% for the ECO-CUTE compared to the conventional fuel boiler system. CO2 COMPRESSION REFRIGERATION Is used mostly in cascade systems where NH3 is used on the high stage. Mycom produces several high pressure compressors (ref.nh3 heat pumps above) which can be used for the compression of CO2. The schematic diagram shows the NH3 and the CO2 cycle, each with compressor, evaporator, condenser and expansion device. The NH3 evaporator/co2 condensor functions as cascade heat exchanger between the 2 circuits. Equipment for compression of CO2 for liquefaction purpose has been produced by Mycom for more than 40 years. The field reference is related to a meat processing installation in Nederland installed in 2005. Kulak, Kortrijk, June.13th, 2012 DOC.2012-345 R0 Page 5

On the low temperature CO2 side 5 high pressure compressors are installed on different temperature levels -51 C, -41 C and -31 C, which cover respectively 4200kW, 2600kW and 3000 kw plant performance. 1 compressor, with design pressure 50 bar, is used for defrosting of the freezers at +10 C. On the NH3 high stage 7 screw compressors are installed. The average operating hours per machine is approx. 38.000 hrs. HYDROCARBON COMPRESSION An Industrial Hydrocarbon Refrigerant Package is shown for Air-Conditioning and Heating. The field reference is a 7 C chilled water production installation of 140 kw in Japan. The application targets for this Hydrocarbon Refrigeration package are food factories, hotels and office buildings. The case study shows that the power consumption and the CO2 emission were reduced with 16 to 14 for the HYDRO-CARBON compared to the conventional R134A system. Kulak, Kortrijk, June.13th, 2012 DOC.2012-345 R0 Page 6

ADSORPTION CHILLER An Adsorption Chiller Utilizing Renewable Energy is shown for chilled water production. Possible heat sources can be solar heat, waste heat, power station waste heat, boiler exhaust heat, process waste heat, etc. The cooling is done by applying condenser (watercooled, evaporative type) The field reference is a 9 C chilled water production installation of 350 kw in Japan. The application targets for this Adsorption Chiller are factories, food factories, hospitals, shopping centers, offices etc. The case study shows that the power consumption and the CO2 emission were reduced with 64% for the ADSORPTION CHILLER compared to the conventional R134A chiller system. AIR COMPRESSION REFRIGERATION An AIR CYCLE Refrigeration System is shown for low temperature applications in the range of -50 C to -120 C. The field reference is a -60 C Ultra Cold Freezing Storage of 5.000m3 in Japan. The AIR CYCLE Refrigeration System is composed of 3 parts : an expander-integrated compressor (compression & expansion), a primary cooler (heat dissipation) and a cold-recovery heat exchanger. The most suitable markets for this Ultra-low temperature refrigerators are tuna & bonito food factories and rapid freezers etc. The case study shows that the power consumption and the CO2 emission were reduced with 54% for the AIR CYCLE REFRIGERATION SYSTEM compared to the conventional R22 two-stage compression refrigerator system. Kulak, Kortrijk, June.13th, 2012 DOC.2012-345 R0 Page 7

CONCLUSION The main goal on zero and low GWP HCFC alternatives has been achieved! 1. All NATURAL 5 REFRIGERANTS comply with a GWP between 0 and 3. (NH3,AIR,WATER : 0, HCO2 : 1, HYDROCARBONS : 3) 2. All NATURAL 5 REFRIGERANTS comply with an ODP = 0. 3. The examples from the field shown in this presentation, all result in significant reductions of CO2-emission and energy consumption : NH3 NEWTON3000 : -30% NH3 hot water : -75% CO2 hot water : -62% HC chilled water : -14% ADSORPTION chilled water : -64% AIR ultra cold air : -54%. The shown results are taken from the field cases presented in this paper and do not represent in general every NATURAL 5 application as those need to be evaluated case by case. In any case the field cases results are based on real operational equipment. The results show attractive positive trends of improvements. Therefore good design praxis is vital to obtain similar or better results than shown in this paper. Kulak, Kortrijk, June.13th, 2012 DOC.2012-345 R0 Page 8