Energy Division. CSJT MV cold shrinkable joint for 3-core cables with resin encapsulation

Similar documents
Energy Division. CSJR / CSJH Cold shrinkable straight joints for polymeric insulated cables up to 36 kv

Section 5: Medium Voltage Joints - up to 42kV

Heat-Shrinkable Termination System for Cables up to 36 kv

MXSU - Selection table 3-core Kits / X-section

Energy Division

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv

RICS. Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv

Terminations. Energy Division. Return to Contents

Raychem Elastomeric Medium Voltage Push-on and Cold-shrink Applicable Terminations TFTI/TFTO

Section 4: Medium Voltage Terminations - up to 42kV

ATUM: General Purpose Thin Wall Tubing - with Adhesive (Black) Medium Wall: MWTM: General Purpose Medium Wall Tubing

RICS. Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv

Section 7: Cable Glands & Duct Seals.

Section 8: Switchgear Connections (Straight & Elbows)

Energy Division. Raychem Insulation Enhancement Systems

Reliable solutions for electrified railway systems

Section 4: Medium Voltage Terminations - up to 42kV.

INDUSTRY /// RAIL T-CONNECTOR RSTI-68R-HT RSTI-CC-68R-HT RAIL APPROVED T-CONNECTORS FOR ROLLING STOCK- TYPE C INTERFACE

PolyGarde Metal-Oxide Surge Arresters

Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series. Energy Division

Insulation and Protection Enhancing the Reliability of Overhead Power Systems

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

RELIABLE SOLUTIONS FOR ELECTRIFIED RAILWAY SYSTEMS

Raychem Raysulate Insulation Enhancement Systems

Connecting the World of Power ENERGY DIVISION

Energy Division. DAH series (IEEE) Distribution metal oxide surge arrester

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

Energy Division. Raychem Raysulate Insulation Enhancement Systems

ENERGY PRODUCTS DIVISION. Polymeric Surge Arresters Reliable protection for power equipment upto 800kV

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

Energy Division. Accessories for the Installation of Low Voltage & Medium Voltage heat-shrinkable products for the Electrical Power Industry

BISG II. Bus Insulator Squirrel Guard. This new and improved isolation guard prevents animal-caused outages in electrical substation equipment.

PETROCHEMICAL SOLUTIONS

ENERGY PRODUCTS DIVISION. Enhancing the Reliability of Cable Networks. Cable Accessories for upto 245 kv

State of the Art in Splicing and Terminating Power Cables. Patrick Lyons Electric Power Sales, Inc.

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA1 Series, (IEC)

TECHNOLOGY WEDGE PRESSURE HV JUICE PAGES 2 & 3. Pop-N-Work Pop-Up Tents PAGE 5. June/July This Issue.

Installation Procedure for D-200 series Shielded Cable Splice Kits with MiniSeal Crimp Primary Splices

ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS

HVS S Splice Series

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

Data Sheet. Self regulating heating tapes. RS stock numbers

Band Heaters. Rectangular Band Heaters, Strip, Ring and Flat Heaters. Contact Accessories, Connection Boxes, Clamping Devices

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing


Evolution of stress control systems in medium voltage cable accessories

WILDLIFE AND ASSET PROTECTION

HVS S 15kV Class

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

RF one-step BNC/TNC connectors for coaxial cable termination

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Tether and Umbilical Cables for Remotely Operated Vehicles

FEB. 17 Rev. A1

TECK-40 Series 1000V Class Splice for 4/C Armored Teck Power Cables

HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE

High Performance LSZH Fire Resistant Cable

ENERGY /// ENERGY ACCESSORIES ENERGY ACCESSORIES

Caledonian fire Resistant signal & Data cables

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

/Oct/2014 Rev B

Raychem Overvoltage Devices. ROV14, ROV14H, ROV14E 14mm Series Metal Oxide Varistors

RAYCHEM MEDIUM VOLTAGE

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

INTERNATIONAL STANDARD

C A Heating Cable Gland Kit

SAFE, FAST PROFESSIONAL WIRING SOLUTIONS STANDARDISED & INDIVIDUAL COMPLEX SMART SOLUTIONS. 25 years: You name it. We have it. DANNEWITZ GmbH & Co

FC22 Compression Load Cell

energy.te.com ONE CLEAR SOLUTION FOR BOTH ROUGH ENVIRONMENTS AND TOUGH SPECS.

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

INTER PLANT STANDARD STEEL INDUSTRY

Data Sheet. Self regulating process heating tapes RS stock numbers ,

VACUUM VALVES AND HOSES

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

Documentation. Parallel Heating Cable. Type: ELP

Cablosam Tapes for Fire-Resistant Cables

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

Raychem Link Boxes. Cable Services Limited. Powering the UK

Raychem Overvoltage Devices. ROV05, ROV05H 5mm Series Metal Oxide Varistors

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Electro-hydraulic crimping tools. HD400-6 Art HD300-6 Art convincing solutions

SOLARLOK Interconnection System Installation Manual

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

RENEWABLE ENERGY. Durable solutions for maximum efficiency and the promise of reliability. ENERGY PIONEERS IN POWER SOLUTIONS

DNVGL-CP-0401 Edition February 2016

Seal Kits for BUDI Enclosures

HEAT SHRINK CABLE ACCESSORIES: A 40 YEARS PROVEN TECHNOLOGY FOR APPLICATIONS IN HARSH ENVIRONMENTS

CryoFit. Handling of Flow Cell and Capillaries. User Guide. Version 002

FOSC. Fiber Optic System Technology. Fiber Optic Splice Closures (FOSC-400)

Snow melting for ramps, access ways, and footpaths

Tools for Cu-terminals mm², Al-terminals mm² (-35 solid) mm² and C-sleeves 6-50 mm²

Caledonian Flame Retardant Coaxial Cables

CABLE & HOSE PROTECTION PRODUCT OVERVIEW

Testing of (E)HV extruded cable systems, a necessary step to achieve system reliability

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

Transportation. Distribution

Introducing SlimSeal SSL Connector

Documentation. Glass -/quartz insulated Heating Cable. Factory terminated. Type: ELK-H, -HS, -Q ELW-H, -HS, -Q

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

Transcription:

Energy Division CSJT MV cold shrinkable joint for 3-core cables

CSJT MV cold shrinkable joint for 3-core cables Features Pre-expanded, single piece silicone rubber joint body with high mechanical expansion properties allows a wide application range Electrical stress control of the screen cut area by integrated conductive geometrical stress cones Electrical stress control of the connector area by an integrated screened connection area (Faraday cage) Pre-expansion on a well-known and easily released holdout system Proven shield continuity concept Hard-elastic polyurethane-type encapsulation with excellent insulation properties, hydrolytic stability and hydrophobic characteristics Fast and easily filled resin outer sealing and protection system Easily installed joint system Exceeds CENELEC HD 629.1, requirements which include IEC, BS, VDE and other international specifications Mechanical shear bolt connectors with a wide application range or copper compression connectors according to IEC 61238-1 can be supplied with the kit 1 2 General CSJT offers a reliable and easy-toinstall jointing system to assure and maintain high network reliability. A silicone rubber joint body with integrated geometrical stress cones and Faraday cage provides excellent electrical stress control. CSJT is designed to cover a wide range of applications and to accommodate the variety of cable and conductor types found in power distribution networks. Range-taking mechanical connectors or copper compression connectors ensuring reliable installation and service can be supplied with the kit. A hard-elastic polyurethane-type encapsulation as protection and sealing system provides an effective moisture seal and robust mechanical protection. Pre-expanded silicone joint body The silicone rubber joint body is delivered in a pre-expanded condition on a spiral holdout system. Silicone materials with excellent mechanical properties allow high expansion ratios and therefore guarantee a wide application range. Integrated stress control mechanism and a conductive outer layer provide exceptional electrical performance. The joint body can be easily removed from the spiral holdout with low release forces, particularly designed for joint applications. Electrical stress control Electrical stress control is fully integrated in the silicone joint body by well defined conductive areas. Conductive cones with an exactly defined geometrical design over the screen cut area provide excellent electrical stress control. The electrical stress control of the connector area is made with an integrated conductive screen performing as a Faraday cage. The coverage of voids and edges at the connection area with void fillers is not necessary and the radial electrical field can be controlled easily.

1 Shield connection 2 Silicone joint body with stress control 3 Half shells 4 Connector 5 Resin 3 4 5 Shield continuity The copper tape shield is connected to the copper braid by a double roll spring connection which provides the required contact force in order to ensure secure installation and reliable performance during load cycling in service as well as during short circuit conditions. Applied over the joint it provides shielding and protection. Outer sealing and protection CSJT joints are available with a resin outer sealing and protection system. It provides a reliable moisture seal, corrosion prevention and robust mechanical protection. The high volume resin bags will be filled into pre-engineered half shells encapsulating the complete joint system. Resin The outer sealing and protection system is based on a hardelastic polyurethane-type casting material with excellent insulation properties. The outstanding properties are the excellent hydrolytic stability and most impressive hydrophobic characteristics. These ensure that foaming problems during processing are avoided, even in a relatively high humidity environment and guarantee long-term stability under service conditions.

CSJT MV cold shrinkable joint for 3-core cables Technical Data Joints qualified in accordance with international test specifications CENELEC HD 629.1 and IEC 60502-4. Excellent Partial Discharge performance proved at 2 U 0 Order Information CSJT - Cold Shrinkable Straight Joints for Polymeric Insulated Cables without connectors Nominal voltage Cross section Ordering Diameter over Diameter over U 0 /U (U m ) (mm 2 ) description core insulation conductor (kv) min. - max. min. - max. (mm) (mm) (mm) (mm) 6.35/11 (12) 95-240 CSJT-12B/3XU-3XU-MY01 18.9-28.4 11.0-19.2 CSJT - Cold Shrinkable Straight Joints for Polymeric Insulated Cables incl. mechanical connectors* Nominal voltage Cross section Ordering Diameter over Diameter over U 0 /U (U m ) (mm 2 ) description core insulation conductor (kv) min. - max. min. - max. (mm) (mm) (mm)(mm) 6.35/11 (12) 95-240 CSJT-12B/3XU-3XU-MY02** 18.9-28.4 11.0-19.2 185-300 CSJT-12C/3XU-3XU-MY02** 23.5-32.6 15.5-21.6 The application ranges given in the table above are based on polymeric insulated cables with stranded circular conductors. Due to different conductor dimensions and constructions the minimum and maximum application range may be extendable. The final application range is specified by the dimensions for core insulation given in the selection table. * These kits are delivered including Tyco BSM mechanical connectors for main conductor. The application ranges given in the table above are valid for cables with stranded conductors. ** Products available on request All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale. Raychem, TE Logo and Tyco Electronics are trademarks. Energy Division economical solutions for the electrical power industry: cable accessories, connectors & fittings, electrical equipment, instruments, lighting controls, insulators & insulation enhancement and surge arresters. Tyco Electronics EPP 1300 3/07 Tyco Electronics Raychem GmbH Energy Division Finsinger Feld 1, 85521 Ottobrunn/Munich, Germany Phone: +49-89-6089-0 Fax: +49-89-6096345 http://energy.tycoelectronics.com