SAFE CONSTRUCTION AND THE ELECTRICITY NETWORK

Similar documents
ETCI Safety Committee TC5. Report for 2013

Welcome to your new home

Electric and Natural Gas Safety and You Teacher s Guide

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 6 Utilities Electrical Emergencies Revised

Schedule of Standard Charges for Distribution Services and Third Party Damage

Mobile home became 50 Non-Work

Electrical Safety. Don't allow trees near power lines to be climbed. Keep ladders, kites, equipment and anything else away from overhead power lines.

ETCI Annual Workshop TC5 Annual Report

Before you begin. Introduction About construction work 1. Topic 1 How health and safety laws apply to you 3

Fire ground electrocution

Electrical & Natural Gas Safety World Video Teacher s Guide

Schedule of Standard Charges for Distribution Services and Third Party Damage

SAFETY AND MAINTENANCE TIPS FOR NATURAL GAS USERS FROM THE VILLAGE OF DIVERNON

Employee Safety Toolkit. Notes:

November This product has been reconfigured Please read these instructions

Ray White Oakleigh. Urgent Maintenance Guide

Safety on the Farm. Volume 44, Number 11 November 2014

Operating Instructions and Safety Precautions for Box-Type Violet Ray Machines with Interrupter Control Only

Electrical safety tips

Electrical & Natural Gas Safety World Video Episode 1 Electricity Basics

OSHA Subpart F Fire Protection and Prevention

FloorHeat Installation Manual

School of Mathematical & Physical Sciences Safety Induction Employees, Students and Visitors

Read the other side, then complete the list below.

putting safety first natural gas

Operating Instructions and Safety Precautions For Box-Type Violet Ray Machine with Rheostat

Manual Handling. Safety Talks for Small Business Part 1 of 9

ANGULAR TILE DRILL BEAST FB750W OPERATING MANUAL

PLAN NOW!! Plan your escape today Your life may depend on it tomorrow HOME ESCAPE PLAN EXERCISE

Electrical Safety Tips. Help us keep you safe.

STEP #4: KNOW WHAT TO DO EARTHQUAKE

Operating Instructions and Safety Precautions for Box-Type Violet Ray Machine with Rheostat

Soil/Landfill compactor Note: It is recommended that you read the Supporting Information page before you read this factsheet.

ATM DEVICE THEFT & ATM GAS ATTACKS:

State of North Carolina Department of Environment and Natural Resources Division of Waste Management. Safety and Risk Management Program

Safety Plan. 2/1/2012 Page 1

FIRE EMERGENCY POLICY

Stay Safe THIS HURRICANE SEASON

Operating Instructions and Safety Precautions for Box-Type Violet Ray Machine with Switched Rheostat

Model: M630-44FDC CAUTION:

Managing Fire Protection System Impairment

Emergency Response Guide for Laboratories

Helpful advice during a power cut

National Broadband Network. User Guide. Includes important information about your NBN equipment

Emergency Procedures Protocol

EMERGENCY RESPONSE GUIDEBOOK South Hamilton Campus February 2016 Reviewed and Updated

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Installation And User Instructions GB/IRE. Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

Telephone: Mobile Number.

Leader s Guide Marcom Group Ltd.

Raft Island Right of Way Vegetation and Tree Management Plan

Guide to the Equipment (Public Safety) Regulations 2017

DANGERS AND HAZARDS OF ENTERING LIVE SUBSTATIONS AND ENCLOSURES Barry Gass Actom Protection and Control

FIRE SUPPRESSION TECHNICIAN

Beau s Emergency Response Plan

Academic and Administrative Buildings

"EVACUATION PROCEDURES"

What Makes Up Your Profile?

Loss Prevention Standards

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

WATCHMAN AREA VOLTAGE DETECTOR

HOW-TO CONDUCT A WEEKLY SAFETY MEETING

BASIC FIRE SAFETY GUIDANCE AT UCL STUDENT HALLS OF RESIDENCES

Emergency procedures flip book

guide to fire safety

Your property and you

PANEL HEATER OPERATING INSTRUCTIONS. For Models: CELEPANEL, CELEPANELT

JUNE NEWSLETTER- FALLIING OBJECTS

OSCILLATING WALL FAN. LISTED For Damp Location E ITEM # MODEL #JP18EB3. Español p. 15 ATTACH YOUR RECEIPT HERE.

ThamesWater Metering Managed Service. Office SHEQ Induction

Don t let a flood wash away what s important to you. Tips and advice to protect you, your family and your home: before, during and after a flood.

FIRE SAFETY. This easy-to-use Leaders Guide is provided to assist in conducting a successful presentation. Featured are:

REGISTER YOUR FREE 2 YEAR GUARANTEE TODAY OPERATING MANUAL ASSEMBLY

General safety precautions English

General safety precautions English

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

Under Carpet Heater Kit Installation Guide

Guide to Gate Safety Legislation & the Machinery Directive

Residential Fire Protection

Electric Floor Grinding Machine. Model FG-11. Operator s Manual

PHOENIX CONVENTION CENTER. EMERGENCY PROCEDURES MANUAL for SHOW MANAGERS

Emergency Procedures Quick Reference Guide

OWNER S MANUAL IMPORTANT SAFETY RULES. Deluxe Maintenance Kit IMPORTANT! DO NOT RETURN PRODUCT TO STORE. English

Guide to Gate Safety Legislation & the Machinery Directive. In Association with:

OWNER S MANUAL IMPORTANT SAFETY RULES IMPORTANT! DO NOT RETURN PRODUCT TO STORE. English

Part 4. Safe Hospitality. Safety, Health & Welfare in Hotels, Restaurants, Catering & Bars. Part 4 - Accommodation and Housekeeping

INSTALLATION & USER INSTRUCTIONS

3gb53231b.fm5 Page 12 Friday, April 11, :21 PM

EMERGENCY RESPONSE GUIDELINES

JAPANESE KNOTWEED GUIDANCE FOR IDENTIFICATION & CONTROL

STANDARDS UPDATE NOTICE (SUN) ISSUED: April 26, 2018

Rules for Rikkyō Global House

Thank you for choosing EnviroVent

SCALES NW EMERGENCY ACTION PLAN

Fire Safety Checklist

Today, we re going to talk about emergency action and fire prevention. We hope we never have to face an emergency situation like a fire in our

Department of Public Safety

Contractor Safety. Workplace Safety & Environmental Division

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

Propane Safety and WILDFIRES

Transcription:

SAFE CONSTRUCTION AND THE ELECTRICITY NETWORK

Always check for overhead wires before you start construction work. Serious accidents have occurred when using cranes, concrete delivery trucks, tipper trucks, scaffolding, telescopic lights or carrying long objects near overhead wires. SAFE CONSTRUCTION AND THE ELECTRICITY NETWORK Before you start excavation work, contact ESB Networks Dial Before You Dig service for up-to-date cable maps at dig@esb. ie or 1850 928 960. #staying-safe

At the planning stage and before starting work near an overhead line, consult ESB Networks at 1850 372 757. INTRODUCTION Electricity is the driving force of our economy. It is so much a part of modern living that we often take it for granted. Electricity is delivered across the country using both overhead wires and underground cables. It is a powerful and versatile source of energy, but can be dangerous unless we use safe systems and procedures. Where safety procedures have not been followed, and where construction work has taken place too close to the electricity network, serious accidents have occurred. Sadly, this has included fatalities. This booklet provides important safety information to help you stay safe when working near overhead wires and underground cables. Please note that this booklet is for general guidance only and should not be regarded as a substitute for professional advice. Such advice should always be taken before acting on any of the matters referenced in this booklet. You should also make yourself familiar with the requirements of the ESB Networks Code of Practice for Avoiding Danger from Overhead Lines and the H.S.A. Code of Practice for Avoiding Danger from Underground Services. These can be downloaded from www.esbnetworks.ie. 5

SAFETY ADVICE WHEN WORKING NEAR OVERHEAD ELECTRICITY WIRES The instantaneous power of electricity is such that any accidental contact with live overhead wires, or coming too close to the wires, will cause serious injury - and can even prove fatal. In the past, serious accidents have occurred when using cranes, concrete delivery trucks, tipper trucks, scaffolding, telescopic lights or carrying long objects near overhead wires. Key to avoiding such accidents is to first take account of the safety implications of overhead wires and then plan to carry out work safely and without incident. Always keep machinery clear and guard against working close to the live wires. Always allow enough clearance to avoid coming close and remember that electricity can jump gaps. For more information refer to the ESB Networks Code of Practice For Avoiding Danger from Overhead Electricity Lines which can be downloaded from www.esbnetworks.ie Working directly beneath or close to overhead electricity lines is extremely hazardous and requires that you put special controls in place to ensure you never breach the Safe Exclusion Zone, including requesting ESB Networks to switch out the electricity lines for the duration of the work. 6 7

AVOIDANCE OF ELECTRICAL HAZARDS WHEN WORKING NEAR OVERHEAD ELECTRICITY WIRES Remember, electricity wires are always live, so you should always consider electricity hazards on site and in your work area. Working near overhead electricity wires is extremely dangerous due to the possibility of either electrical arcing or direct contact. So before you start work near overhead lines or even when you re only planning such works always phone ESB Networks on 1850 372 757. There are two general hazard situations; Sites where there will be no work or passage of machinery under a live overhead electricity wire. Barriers and bunting must be put in place at a safe distance and must run parallel to the electricity wires. Barriers may either be fixed post fencing or steel drums filled with rubble and spaced 1.5 metres apart If cranes are in use, a line of visible bunting at a height of 3 metres is required to supplement the barriers. Danger notices with the words Danger Live Overhead Wires should be spaced at a maximum distance apart of 20 metres. Sites where there will be work or passage of machinery under a live overhead electricity wire. In addition to the safety measures mentioned above, the following safety measures must also be carried out: Solid, non-conducting goal posts must be in place, with dimensions as follows: The height of the goalposts must not exceed 4.2 metres, except where otherwise advised by ESB Networks. The width of the goalposts must be no greater than 9 metres wide. The height of the bunting must be between 3 metres and 4.2 metres. All barriers must be placed at the extremity of the Hazard Zone. The Hazard Zone surrounds the electricity wires and extends from the outside electricity wire. The Hazard Zone is a minimum of 6 metres for all low voltage, 10kV, 20kV and 38kV electricity wires. The Hazard Zone is a minimum of 10 metres for 110kV, 220kVand 400kV electricity wires. If you are unsure of the voltage of nearby power lines, please request map records from ESB Networks at dig@esb.ie or on 1850 928 960. 8 9

REMEMBER THESE 5 STEPS TO STAYING SAFE. In the event of an incident involving accidental contact with overhead electricity wires, remember these steps and Stay Safe: STEP 1: KEEP CLEAR The driver or operator of plant or machinery that comes into contact with overhead wires will usually remain safe in the cab. However, other people on the ground are at serious risk if they make contact with the plant or machinery - or their attachments. It is never safe to rely on rubber tyres or rubber-soled boots for protection they will not insulate against high voltage shock. Tyres can burst into flames and boots can be destroyed. STEP 2: CONTACT ESB NETWORKS You or someone else should immediately phone the ESB Networks Emergency number - 1850 372 999 STEP 3: JUMP CLEAR If you must exit the cab, jump clear so that contact is not made between you, the vehicle and the ground. Land on your feet and do not touch the ground with your hands. Move away carefully by shuffling, keeping both feet together -or bunny hop with both feet close together. STEP 4: STAY CLEAR Do not go back to the vehicle as it may still be live. Wait until ESB Networks has confirmed that it is safe to do so. Many fatal accidents have occurred when the person has jumped clear, but then returns to the vehicle. STEP 5: SAFE OPERATION In some situations, it may be possible to reverse away until contact is broken. Do not climb out of the vehicle or attempt to operate the vehicle when standing on the ground outside the vehicle. Never make contact with the live vehicle and the ground at the same time. For more detailed information, please refer to the ESB Networks Code of Practice for Avoiding Danger from Overhead Electricity Lines, which can be downloaded from www.esbnetworks.ie. 10 11

AVOIDANCE OF ELECTRICAL HAZARDS WHEN WORKING NEAR UNDERGROUND ELECTRICITY CABLES Serious accidents have occurred when cables have been struck or disturbed, often resulting in life-threatening and life-changing injuries. It is important to always take the essential safety precautions before carrying out digging work, as there often will be buried electricity cables close by. It is never safe to disturb or handle electricity cables. Before you start digging: Contact ESB Networks Dial Before You Dig service and obtain the relevant, up-to-date cable maps - dig@esb.ie or 1850 928 960 Complete a Risk Assessment Method Statement (RAMS). Remember that service cables and public lighting cables may not be shown on the map. Always assume that there are more buried cables present than you have located. Look out for any indication of other services such as gas, water, etc. Ensure a Cable Avoidance Tool is used by a competent operator to locate all services. Mark the positions of the cables using waterproof crayon, chalk or paint and ensure it is visible to the machine operator. When working near underground electricity cables, always use: Your Company Policies, Procedures, Method Statements and the relevant Code of Practice. Maps and Cable records. A suitable and appropriate Cable Avoidance Tool (CAT). This must be used by a competent operator. Safe Digging Practice. Always be aware that the depth of cover may be very shallow and that there may be no bricks, warning tape or other protection in place. For more detailed information, please refer to the H.S.A. Code of Practice For Avoiding Danger from Underground Services available from www.hsa.ie Also available: ESB Networks Booklet - How You Can Avoid Hitting Electrical Cables When Digging and Drilling available from www. esbnetworks.ie 12 13

ARE YOU SURE IT S SAFE? HOW TO CONTACT ESB NETWORKS Avoid the dangers of underground electricity cables. Contact us to get maps which show the locations of ESB Networks underground cables. 1850 928 960 01 6388169 dig@esb.ie In case of emergency, phone 1850 372 999 (24 HOUR/7 DAY SERVICE) www.esbnetworks.ie GENERAL QUERIES Contact ESB Networks on 1850 372 757 or 021 2386 555 Our lines are open Monday to Friday 8.30am to 6pm and Saturday 8.30am to 1.30pm If possible please have your MPRN number to hand when calling us. esbnetworks@esb.ie Our target is to have your query addressed within two working days. SAFE DIGGING Email your request, with your site map to dig@esb.ie Call 1850 928960 Fax 0 1 6388 169 Alternatively, you can make a postal request to: Central Site ESB Networks St. Margaret s Road Finglas Dublin 11 FAULTS/EMERGENCIES AND INTERRUPTIONS IN SUPPLY For Faults/Emergencies (24 hours/7days service) contact ESB Networks Emergency number on 1850 372 999 or 02 1 23824 10 For Real Time Information on Faults and Outages go to ESB PowerCheck www.powercheck.ie Follow us on www.twitter.com/esbnetworks 14 15

THINGS TO REMEMBER WHEN WORKING NEAR OVERHEAD WIRES AND UNDERGROUND CABLES. SAFE CONSTRUCTION AND Do phone ESB Networks immediately at 1850 372 999 in case of an emergency. Do contact ESB Networks to obtain the relevant maps before construction. Do contact ESB Networks to request a switch out of the electricity networks to ensure safe working. Do remember that electricity wires are always live. Do stay clear of overhead electricity wires. Do identify the location of buried cables. Do follow the requirements set down in the relevant Codes of Practice. Do display safety stickers on machinery to remind everyone to be electricity safe. Call 1850 372 757 to obtain these stickers. Don t work close to overhead wires. Don t disturb underground cables. Don t undermine pole or mast foundations. Don t touch or come near to fallen wires. Don t approach or touch anything that may be in contact with electricity wires. 16 17

YOUR NOTES 18

esbnetworks.ie