Battery Performance Alert

Similar documents
Battery Performance Alert: A TOOL FOR IMPROVED PATIENT MANAGEMENT FOR DEVICES UNDER BATTERY ADVISORY

Brine Generation Study

White Paper: Video/Audio Analysis Technology. hanwhasecurity.com

SOFTWARE VERSION 8.5 FAQs

Real Time Pipeline Leak Detection on Shell s North Western Ethylene Pipeline

2017 Annual Report. King County Fire District No. 27 Fall City, WA

ADVANCED MONITORING AND DIAGNOSTIC SYSTEMS FOR INDUSTRIAL GAS TURBINES

Wireless Call Point ( )

False Alarm Suppression in Early Prediction of Cardiac Arrhythmia

Regulation of Alarm Remote Notification Systems

Alarm Fatigue in the ICU. Lynn Maguire MS, RN, PMC, NE-BC

Banff Mineral Springs Hospital EMERGENCY RESPONSE CODE RED Fire

Architectural and Engineering Specification for a. Flash / Flare

WHITE PAPER FEBRUARY Oracle Retail: Optimize Performance and Reduce Business Risk

Advanced Diagnostics for HART Protocol Rosemount 3051S Scalable Pressure, Flow, and Level Solutions

Radar technology in surveillance

Application Note. Application Note for BAYEX

Research Needs for the Fire Safety Engineering Profession

2013 Compliance Report RCW 52.33

You finally make it home after a long shift, shower,

2 A e ( I ( ω t k r)

Remote Monitoring of Offshore Structures using Acoustic Emission.

WHO PQS-Code E006/020. Fridge-tag 2 Storage temperature monitor with USB port

Alarm Management Implementation on a Plant. Standards Certification Education & Training Publishing Conferences & Exhibits

Oxford Fire Department: 2008 Service Analysis. Prepared for the Subcommittee studying the Oxford Division of Fire. April 8, 2009

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

Hospital Preparedness: A Pilot Program for Radiation Monitoring in Emergency Departments

Computer Modelling and Simulation of a Smart Water Heater

Saying Mahalo to Solar Savings: A Billing Analysis of Solar Water Heaters in Hawaii

Application Notes for Configuring NovaLink NovaAlert SIP with Avaya IP Office Issue 1.0

BNWAT28: Water consumption in new and existing homes

6 th Pipeline Technology Conference 2011

LineGuard 2300 Program User Manual (FloBoss 107)

Managing Clinical Alarms

RESULTS FROM HOUSE APPLIANCE SAFETY AND DEPRESSURIZATION TESTS CONDUCTED ON SINGLE FAMILY HOUSES UNDERGOING SOUND INSULATION

Architectural and Engineering Specification for a Real-Time Locating System Flare

City of Los Angeles Office of the Controller

Identification of Aberrant Railroad Wayside WILD and THD Detectors: Using Industry-wide Railroad Data. June 10, 2014

Sensor Cloud User Manual

S TAR-ORION S OUTH D IAMOND P ROJECT E NVIRONMENTAL I MPACT S TATEMENT APPENDIX A FUNDAMENTALS OF ACOUSTICS

Batt-Safe Battery String Monitoring System

Effective Alarm Management for Dynamic and Vessel Control Systems

ThermoControl 0 C - 10 C - 20 C - 30 C

Intelligent alarm management

Samsung SDS BMS Ver.2.0. Technical Specification

Automated Medication Kit

Simplex Panel Interface Guide

Altitude Chambers.

Jon Longtin Department of Mechanical Engineering SUNY Stony Brook

Reduced Order WECC Modeling for Frequency Response and Energy Storage Integration

Clinical Alarm Effectiveness: Recognizing & Mitigating Risk to Patient Care

WiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title

THE EDDY IQ METER PRODUCT MANUAL

Maluna Unhinged vs Yeti Tundra Thermal Performance Comparison January 2017

White Paper. Fog Detection and Defog Technology. hanwhasecurity.com

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

What's new in LogTag Analyzer 2.8

Universal Tag Locator. Operations management software for process facilities

REMOTE AUTOMATIC INCIDENT DETECTION USING INDUCTIVE LOOP DETECTORS

Fiber Optic Cable Fence Disturbance Sensor

Accurate Heat Detection with Health Monitoring

80BPM 36.5 C 35/ / 80. Panorama CENTRAL MONITORING SYSTEM. efficient flexible versatile (18) (94) Adult A SMITH, ERICA (92) 5RPM.

What's new in LogTag Analyzer 2.8

BeneVision Central Monitoring System. Quick Reference Guide

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

The New DUSTTRAK II and DRX Aerosol Monitors

Establishing the Risk Basis of Building Size Limits

Zenatek Tracking System

National Grid Residential Active Demand Reduction Demonstration Project. MA EEAC Demand Reduction Sub-Committee February 23, 2017

ONYXWORKS AND FIRSTVISION. Version 4

Alarm Management at Boston Medical Center A Roadmap to Safe Silence

EasyLog Data Logger Series

What Utility Analytics means to Exelon

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

Artificial Intelligence Enables a Network Revolution

The New DUSTTRAK II and DRX Aerosol Monitors

Functional Safety: the Next Edition of IEC 61511

Alarm Management. Objectives

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

DynAMo Alarm & Operations Management

Getting Started with Live Exceptions

Nest Learning Thermostat Summer 2012 Savings

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Effective Use of Statistical Models to Establish and Update Vibration Alarm

Shell Canada Limited Hydrogen Sulphide (H2S) Release September 12, 2006

OPI-integris Advantages

Enhanced FOUNDATION Fieldbus Physical Layer Diagnostics with the DeltaV System

LEADING THE INDUSTRY THROUGH INNOVATION. UNILINC TM CONTROL SYSTEM

EasyLog Data Logger Series

Standard PRC Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance

Approved by Principal Investigator: Date: Approved by Laser Safety Officer: Date:

URGENT - Field Safety Notice Medical Device Correction

Approved by Principal Investigator: Date: Approved by Laser Safety Officer: Date:

WILDLIFE DETECTION AND ACTIVE WARNING SYSTEM SYSTEM OPERATIONS SUMMARY

Temperature & Humidity Monitoring For Museums & Heritage Product Guide.

AN ANALYSIS OF THE PERFORMANCE OF RESIDENTIAL SMOKE DETECTION TECHNOLOGIES UTILIZING THE CONCEPT OF RELATIVE TIME

WeatherLink for Alarm Output Addendum

WHO PQS-Code E006/016. Q-tag CLm doc USB Multi- Limit Temperature Indicator

C-NRPP Quality Assurance Guidance for Radon Test Devices

Continuous Commissioning: A Valuable Partner to Retrofit Projects

Transcription:

Battery Performance Alert A TOOL FOR IMPROVED PATIENT MANAGEMENT FOR S UNDER BATTERY ADVISORY VERSION 2.0

Abstract BACKGROUND: In October 2016, St. Jude Medical (now Abbott) issued an advisory on a family of ICD and CRT-D devices that may develop Lithium deposits within the battery leading to a short circuit and result in premature and potentially rapid battery depletion. We have developed and evaluated a battery performance algorithm to detect and alert to abnormal battery behavior associated with devices that are likely to experience premature battery depletion due to this mechanism prior to reaching the Elective Replacement Indicator (ERI). METHODS A software algorithm for the Merlin.net PCN system and Merlin PCS programmer systems was developed to monitor battery performance and alert the clinician when anomalous behavior is present. The alert generated by this algorithm is referred to as the Battery Performance Alert (). The Battery Performance Alert () algorithm analyzes the daily battery voltage measurements and identifies deviations from the expected voltage behavior that may be indicative of abnormal battery performance. The ability of the to detect and trigger an alert to abnormal battery performance was evaluated on advisory devices returned for premature battery depletion and returned devices that were performing normally. Metrics of sensitivity, specificity, and time from alert to End of Service (EOS) were determined. The algorithm was further augmented by development of an ICD/CRT-D device based alert that allows for continuous monitoring with upgraded device firmware. Please refer to Appendix A for more information and the performance data associated with the device based alert. RESULTS The algorithm sensitivity, defined as the ability of the algorithm to detect abnormal battery performance prior to ERI, was 97.8% with a 95% lower confidence bound of 95.4%. The specificity, defined as accurately not alerting when a battery was performing normally, was 99.8% with a 95% lower confidence limit of 99.5%. The time to react to an alert is increased six times with the addition of the. In the test data set, the median time from alert to EOS without (i.e. ERI to EOS, including cases where an ERI alert was not generated prior to EOS) was 2 days (interquartile range [IQR] 0 4 days). Using the exact same devices, with, the median time from alert to EOS was 12 days (IQR 8 17.25 days). Without the, the probability of a patient with an advisory device reaching EOS with 1 day warning is 0.18%. With the addition of the alert, the overall probability of a device with a battery subject to the advisory reaching EOS with 1 day warning is 0.004%. CONCLUSION The study suggested that the algorithm is a highly sensitive and specific tool that increases time from alert to EOS on devices subject to the October 2016 advisory. It accurately and reliably alerts to abnormal battery performance in these devices and has a high specificity demonstrating a low probability of a false alert in a normally functioning battery. Most importantly, the study demonstrated that provides notification of an abnormally functioning battery earlier than the existing alert which is triggered by the battery voltage reaching a certain level (i.e., ERI), thus providing more time for identification and management of patients with advisory devices. 2 Battery Performance Alert

Introduction In October 2016, St. Jude Medical (now Abbott) issued a global medical device advisory to notify physicians that the batteries in a subset of implantable cardiac defibrillator (ICD) and cardiac resynchronization therapy defibrillator (CRT-D) devices may have the potential to experience premature battery depletion (PBD). The batteries in these devices were determined to be susceptible to the formation of Lithium (Li) deposits near the anode and cathode of the battery that could cause a short circuit and result in premature and/ or rapid depletion of the battery. As of data through November 30, 2017, the worldwide incidence of PBD was 0.35%. 1 At the time of the advisory, the Elective Replacement Interval (ERI) alert was the only notification to patients (vibratory alert) and physicians (via Merlin.net Patient Care Network [PCN] remote monitoring or an in-clinic Merlin Patient Care System [PCS] programmer alert message) that a device would need to be replaced. The ERI alert is generated when the battery voltage measured by the device is consistently below a specified voltage threshold. Initial investigation indicated that if a short circuit occurs, battery depletion from ERI detection to the End of Service (EOS) voltage or below could potentially occur within a day, but typically within weeks. The time from ERI alert to EOS was 1 day (including some with no alert at all) in approximately 20% of devices returned for PBD. 1 This is the primary clinical concern for patients with devices impacted by the battery advisory as they may suddenly, with little notice, no longer be able to receive device therapy. Investigation of the daily battery voltage measurements in devices returned due to PBD indicated that there were observable changes in the battery voltage measurements occurred days to months prior to the device reaching the ERI voltage. This led to the research and development effort of creating an algorithm, with the goal of providing a reliable and timely alert to the clinician in the instance of PBD. Methods A software algorithm for the Merlin.net PCN system and Merlin PCS programmer systems was developed to monitor battery performance and alert the clinician when anomalous behavior is present. The alert generated by this algorithm is referred to as the Battery Performance Alert (). Development of this algorithm was performed using the following steps. First, device battery voltage information was extracted from out of service devices under the battery field advisory. Second, the battery voltage trends of these devices were analyzed for patterns of normal versus abnormal battery behavior. Using this information, the software algorithm was developed to detect abnormal battery behavior and, in turn, device PBD. The algorithm performance was then validated with adjudicated device battery trends from actual devices. BATTERY VOLTAGE DATA Battery voltage trend data from devices subject to the October 2016 battery advisory was used to develop and test the algorithm. Data was obtained from the following devices: Explanted and returned due to complaint of PBD associated with Li deposit formation Out of service, no complaint (including those explanted prophylactically). All available Merlin.net PCN and returned product data was extracted for these devices. The data was split into two sets. Battery voltage data from a total of 3,719 unique devices was used to develop and optimize the algorithm for detection of abnormal battery voltage (development set). Data from a total of 2,293 unique devices was used for validation of the algorithm performance (validation set). ALGORITHM DEVELOPMENT Abbott ICDs and CRT-Ds maintain a running log of the most recent 32 daily battery voltage measurements. Along with the measured values, an expected battery curve is calculated based on the expected battery use. Battery voltage measurements in a normally functioning device will closely track the expected battery curve. Expected deviations may be noted for known transient events of heavy battery use such as high voltage charging. Figure 1 shows a 32 day battery voltage trend of both expected (green line) and measured battery voltage (yellow line) for a device with a battery that is performing normally. Premature battery depletion was defined as the device battery voltage dropping suddenly or more rapidly than expected. Rules to quantify the discrimination of PBD from normal battery operation were derived based on the development data. Battery Performance Alert 3

Battery Voltage (V) Figure 1 NORMAL 3.03 HV CHARGING 2.63 Three specific types of patterns were identified in the battery voltage trends that indicate that the battery is not performing as expected. The algorithm was developed to trigger if these specific patterns are noted when comparing the measured battery voltage to the expected battery voltage. These patterns are: Sudden Drop Deviated Voltage Delayed Recovery Figure 1: A 32 day battery voltage (BV) trend for a normally functioning battery. The device is interrogated on the right hand edge of the graph and the voltages are from the thirty two prior days. High voltage charging (and other heavy transient usage, e.g. extended RF telemetry) results in a sudden drop in battery voltage that recovers over the course of approximately 10 days. This is reflected in the Measured BV trend, but not the Expected trend. The algorithm accounts for this normal behavior. Figure 2 NORMAL A. SUDDEN DROP B. Battery Voltage (V) 3.03 HV CHARGING 2.63 Battery Voltage (V) 3.03 2.63 HV CHARGING DEVIATED VOLTAGE C. DELAYED RECOVERY D. Battery Voltage (V) 3.03 HV CHARGING 2.63 Battery Voltage (V) 3.03 HV CHARGING 2.63 Figure 2: Examples of a normal BV trend (Panel 2a) and each of the patterns that the will detect. The arrow indicates the earliest detection point in each case. 4 Battery Performance Alert

Figure 2 contains graphical examples of each of the patterns that the detects along with an example of a normal battery performance curve. The Sudden Drop rule (Figure 2b) looks for a sudden decrease in measured battery voltage not associated with a high battery usage event. The Sudden Drop rule will trigger an alert in one to three days, depending on the magnitude of the voltage drop. A large drop will be detected within one day, whereas it may take 3 days if there are a series of small drops. This is the primary rule that protects against the case of a complete short resulting in a battery voltage going from normal to EOS in a matter of days. The Deviated Voltage rule (Figure 2c) detects the case where the battery voltage drops from the expected level and then resumes predictable battery consumption but at a baseline level significantly lower than expected based on historical device usage. This case is likely due to a transient short. The third pattern is referred to as Delayed Recovery (Figure 2d). In this case, the battery voltage takes a longer time to recover to baseline than expected after a heavy battery usage event. ALGORITHM VALIDATION To validate the performance of the, battery voltage trends were adjudicated by trained professionals, trends were processed through the algorithm, and results of adjudication versus algorithm determination were compared. Battery voltage trends of the available data were created for each of the 2,293 devices used for validation of the. The duration of these trends contained as many measurements as available for each of the devices, a minimum of 30 and up to a max of 365 days prior to the final available measurement. These trends were adjudicated as normal or abnormal by a minimum of two independent, blinded, trained adjudicators. The battery voltage trends were adjudicated as normal if the measured battery voltage tracked the expected battery voltage for the duration of the data. Conversely, trends were adjudicated as abnormal if there were significant deviations from the expected battery voltage. Disagreements were resolved by consensus. The battery voltage trends were then processed through the algorithm in 32 day windows (one device session at a time) to determine if and when the algorithm detected an anomaly. This process simulated the performance of the algorithm as would occur with daily Merlin.net PCN remote follow-up. PERFORMANCE ANALYSIS The following analysis was performed to assess the performance of the Battery Performance Alert. Sensitivity algorithm sensitivity was calculated as: Number of BV trends adjudicated as abnormal with detection prior to ERI Sensitivity = x 100 Specificity TIME FROM ERI TO EOS Total number of BV trends adjudicated as abnormal algorithm specificity was calculated as: Number of BV trends adjudicated as normal without detection Specificity = x 100 Total number of BV trends adjudicated as normal To further understand the current field experience, the time from ERI detection to EOS was determined for all of the devices that were adjudicated as abnormal and had reached the EOS voltage in the available data. TIME FROM DETECTION TO EOS To assess the improvement in time from alert to EOS, the time from triggering of to EOS was also calculated for all of the devices that were adjudicated as abnormal and had reached the EOS voltage in the available data. Battery Performance Alert 5

Results ADJUDICATION AND DATA SUMMARY: There were 2,293 devices included in the validation data set. Of those, 224 devices were adjudicated as abnormal and the remaining 2,069 were adjudicated as normal. There was 95% agreement between the adjudicators with the majority of disagreements relating to devices exhibiting the delayed recovery pattern. Of the abnormal devices that had reached EOS (n=52), 46.2% (n=24), had 1 day from ERI detection to EOS. same devices, with the, the median time from alert (i.e., ) to EOS was 12 days (IQR 8 17.25 days); this represents a sixfold increase in time to react. The time from alert to EOS analysis was limited to devices that actually reached EOS. Figure 3 DAYS FROM ALERT TO EOS SENSITIVITY AND SPECIFICITY The sensitivity was defined as the ability of the to detect and alert to abnormal battery performance prior to detection and alert of ERI. Among the 224 devices that were adjudicated as abnormal, a was triggered prior to ERI in 219 devices. Therefore, the sensitivity is 97.8% (219/224) with a 95% lower confidence bound of 95.4%. The five devices that were adjudicated as abnormal but were not detected as abnormal by the were all well above the ERI voltage. Thus it is likely that the would have triggered prior to the device reaching the ERI voltage, however, the data is not available to confirm. The triggered an alert at least one day prior to ERI in 100% of the 110 devices where the battery reached the ERI voltage. Specificity was defined as correctly not alerting for devices with normally functioning batteries. Among 2,069 devices that were adjudicated as normal, 2,064 devices did not have detection. Therefore, the specificity is 99.8% (2064/2069) with a 95% lower confidence bound of 99.5%. TIME FROM ALERT TO EOS As the time from alert to EOS is critical in timely management of advisory patients, the ability of to reliably increase this time is a key metric. In the validation data set, fifty-two of the devices adjudicated as having abnormal battery performance reached EOS. Of those, 46% of devices (n=24) had 1 day between ERI detection and EOS. With ERI detection as the only method of notification to a failing battery (i.e. without ), the median time from alert to EOS was 2 days (interquartile range [IQR] 0 4 days). Using the exact Table 1-100 -80-60 -40-20 0 Time from alert to EOS Without : Median - 2 days (IQR o - 4 days) With : Median - 12 days (IQR 8-17.25 days) Without (ERI to EOS) With ( to EOS) 2 days 54% 100% 1 week 12% 89% 4 weeks 0% 10% EOS WITH Figure 3: Summary of time from Alert to EOS, with and without. Analysis limited to devices that reached EOS (52 out of 224 abnormal devices) TIME FROM ALERT TO EOS WITHOUT 6 Battery Performance Alert

Discussion The primary clinical concern for patients with devices impacted by the battery advisory is sudden battery depletion that may leave the device unable to deliver necessary therapy without a timely notification. Prior to, ERI detection was the only warning of a battery that was failing, and in some incidences, ERI alert was generated less than 1 day before the device reached EOS or not even delivered at all. With the introduction of, a timely management of those advisory devices is feasible with an earlier detection and notification of abnormal battery performance. Our analysis demonstrated that the correctly detected abnormal battery performance in 97.8% of the devices adjudicated as abnormal and detected abnormal performance at least one day prior to ERI in 100% of the devices that had reached ERI. Further, the indicated abnormal battery performance in only 0.2% of battery data adjudicated as normal. As shown in Table 1, there was at least two days between and EOS in 100% of the 52 devices that had reached EOS, and 89% of the devices had at least 1 week from alert to EOS with. Conclusion The provides a reliable tool for management of patients that have devices with batteries at risk of premature depletion due to unexpected shorts. The validation testing demonstrated that the detects and alerts to abnormal battery performance earlier than the existing alert mechanisms and has a high specificity, demonstrating a low probability of a false alert in a normally functioning battery. The limitation of this analysis is that it was performed retrospectively using data collected from devices that were already out of service and a full set of data was not available for all devices. However, all of the data is from devices that are part of the advisory population and includes devices that had been returned for premature battery depletion and had evidence of Li clusters. Further, data was available to directly compare the expected improvement with the addition of the alert. Based on the estimated six year combined Kaplan- Meier (KM) survival curve, the freedom from premature battery depletion associated with Li deposits in the affected device population is 99.089%. 1 Without the algorithm, the probability of a patient having a device reach EOS with 1 day is 0.18%. With the addition of the alert, the overall probability of having a device reach EOS without prior warning is 0.004%. Battery Performance Alert 7

Appendix A The earlier battery performance alert () algorithm was primarily based on daily monitoring via the Merlin.net PCN system. Battery information from the implanted device was uploaded automatically each night to Merlin.net PCN system, and analyzed to determine if an anomalous battery voltage trend was observed. Once a was triggered, notification would be provided to physicians through the Merlin.net PCN system. For patients not followed remotely with Merlin.net PCN system, the status of their device s battery and whether the algorithm had triggered an alert could only be determined during an in-person interrogation using the Merlin programmer. Figure 4 DAYS FROM ALERT TO EOS WITH ICD/CRT-D BASED The introduction of a device based alert allows patients to be continuously monitored through the ICD/CRT-D device firmware without interrogation by a programmer or Merlin.net PCN and analyze the battery trend within the device. Once a device based is triggered, a vibratory patient notifier is immediately delivered to the patient. Notification will also be provided to the physician through an automatic Merlin.net PCN system alert transmission or at the next in-clinic interrogation using the Merlin programmer. The performance of the device based algorithm was evaluated using the validation data set (2,293 devices) that was previously used for validation of the software algorithm for the Merlin.net PCN system and Merlin PCS programmer system. Metrics of sensitivity, specificity, and time from alert to End of Service (EOS) were determined. -100-80 -60-40 -20 0 EOS WITH MERLIN.NET/ MERLIN PCS WITHOUT SENSITIVITY AND SPECIFICITY: The sensitivity was defined as the ability of the device-based to detect and alert to abnormal battery performance prior to detection and alert of ERI. In the validation data set, 224 devices were adjudicated as abnormal. Among them, 218 had device-based detection prior to ERI. Therefore, the sensitivity is 97.3% (218/224) with a 95% lower confidence bound of 94.8%. This is equivalent to the performance of the software algorithm; however one device was detected by the software algorithm that was not detected by the device-based algorithm. This device was not detected due to an approximation in the expected battery curve necessitated by the limited processing capacity of the device. Specificity was defined as the device-based correctly not alerting for devices with normally functioning batteries and normal battery trends. There were 2,069 battery voltage trends adjudicated as normal. Among them, 2,064 did not have a device-based detection. Therefore, the specificity is 99.8% (2064/2069) with a 95% lower confidence bound of 99.5%. This is identical to the performance of the software algorithm. TIME FROM ALERT TO EOS Analysis of the software algorithm for the Merlin PNC system and the Merlin PCS programmer systems demonstrated a sixfold increase in the time to notification. Analysis of the device-based algorithm demonstrated identical performance, with a median time from to EOS of 12 days. A comparison summary can be found below. Table 2 Without : Median - 2 days (IQR 0-4 days) With Software : Median - 12 days (IQR 8-17.25 days) With Device-Based : Median - 12 days (IQR 8-17.25 days) Figure 4: Summary of time from Alert to EOS, with and without device-based or software. Analysis limited to devices that reached EOS (52 out of 224 abnormal devices) Time from alert to EOS TIME FROM ALERT TO EOS Without (ERI to EOS) With Merlin.net/ Merlin PCS ( to EOS) With ICD/ CRT-D Device Based ( to EOS) 2 days 54% 100% 100% 1 week 12% 89% 89% 4 weeks 0% 10% 10% References 1. Medical SJ. ICD Premature Battery Depletion Advisory Update - January 2018. 2018. https://www.sjm.com/en/professionals/ resources-and-reimbursement/technical-resources/product-advisories-archive (accessed February 14 2018). Abbott One St. Jude Medical Dr., St. Paul, MN 55117 USA, Tel: 1.651.756.2000 SJM.com St. Jude Medical is now Abbott. Brief Summary: Prior to using these devices, please review the Instructions for Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use. TM indicates a trademark of the Abbott group of companies. 2018 Abbott. All Rights Reserved. SJM-CRM-0218-0120(1) Item approved for global use.